You are on page 1of 32

GRUNDFOS A WIDE RANGE OF QUALITY PUMPS

50 Hz
GRUNDFOS

A global business

With over 10,000 employees and annual production of


some 8 million pump units a year, Grundfos is one of the
world’s leading pump manufacturers. More than 50 compa-
nies right across all the continents of the globe help to bring
pumps to every corner of the world, from supplying drinking
water to Antarctic expeditions, irrigation of Dutch tulips,
groundwater monitoring beneath waste heaps in Germany,
to air-conditioning in Egyptian hotels.

Efficient, sustainable products Research and development make use of the latest techno-
Grundfos is constantly striving to make its products more logy within the pump industry, collaborating with universi-
userfriendly and reliable – and also energy-saving and effi- ties and higher education institutions in search of new and
cient, so that both users and the environment benefit from better solutions for the design and function of the products.
their improvements.
Grundfos pumps are equipped with ultramodern electron- Corporate values
ics, allowing them to regulate their output according to cur- The Grundfos Group is based on values such as sustainabil-
rent needs. This not only ensures convenience for the user, ity, openness, trustworthiness, responsibility, and also on
but also saves a great deal of energy. partnership with clients, suppliers and the whole of society
around us, with a focus on humanity that concerns our own
Research and development employees as well as the many millions who benefit from
In order to maintain its leading position, Grundfos con- water that is procured, utilised and removed as wastewater
stantly places a great deal of emphasis on customerori- with the help of Grundfos pumps.
ented research and development; customers are consulted
when new products are developed or when established
products are improved.

3
Pumps for all purposes

No matter for which purpose an efficient and energy-


saving pump solution is required, Grundfos offers a
high-quality solution.

Heating and hot water Cooling and air- Industrial Pressure boosting and Groundwater
service systems conditioning systems applications liquid transfer supply

Circulator pumps for Circulator pumps for A wide range of Vertical and hori- Submersible and dry
circulation of hot circulation of cold pumps for the trans- zontal, centrifugal installed pumps for
water in central and water and other fer of water, cooling pumps and pressure groundwater supply,
district heating sys- liquids in cooling lubricants and other boosting systems for irrigation and
tems and circulation and air-conditioning liquids in industrial liquid transfer and groundwater lower-
in domestic hot systems. and process systems. boosting of hot and ing.
water service sys- cold water.
tems.

4
GRUNDFOS

Domestic water Sewage and wastewater Environmental Dosing Renewable-energy


supply applications systems

Submersible pumps, Drainage, effluent Purpose-built Dosing pumps for Renewable-energy-


jet pumps, multistage and sewage pumps, submersible pumps wastewater treat- based water supply
centrifugal pumps for a wide range of for remedial pumping ment systems, systems suitable for
and compact systems applications in build- of contaminated swimming-pools and remote locations not
for water supply in ing services as well groundwater and for industry. connected to the
homes, gardens and as transfer of raw sampling for water electricity supply grid.
hobby applications. sewage in municipal quality analyses.
sewage systems.

5
Product and application overview

Heating and hot water service systems Industrial applications


Delta Control 2000. . . . . . . . . . . . . . . . . . . . . . . 11 AMD, AMG, AFG . . . . . . . . . . . . . . . . . . . . . . . . 26
DME, DMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 BMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 BM, BMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
GRUNDFOS ALPHA+ UPS, UP Series 100 . . . . . . . . . .8 BME, BMET. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
GRUNDFOS COMFORT UP-N, UP(S)-B Series 100 . . . . .8 BMEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
GRUNDFOS MAGNA, UPE Series 2000. . . . . . . . . . . .9 CH, CHN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
LM, LP, CLM . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 CHI, CHIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LME, LPE, CLME, TPE . . . . . . . . . . . . . . . . . . . . . . 10 CHIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 CHV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
NBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Contra. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Control 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . 19
NKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
NM, NP, DNM, DNP . . . . . . . . . . . . . . . . . . . . . . 11 CRE, CRIE, CRNE. . . . . . . . . . . . . . . . . . . . . . . . . 17
TP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 CRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
TPE Series 2000 . . . . . . . . . . . . . . . . . . . . . . . . . 10 CV, CPV, CPH . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
UPS Series 200 . . . . . . . . . . . . . . . . . . . . . . . . . .8 DME, DMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
DP, EF, SE1 and SEV . . . . . . . . . . . . . . . . . . . . . . . 29
Cooling and air-conditioning systems DW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
CHI, CHIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Euro-HYGIA®. . . . . . . . . . . . . . . . . . . . . . . . . . . 17
CHIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Hydro 2000, Hydro 1000, Hydro Solo, Hydro Multi-E. . 19
CH, CHN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
LM, LP, CLM . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
CHV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
LME, LPE, CLME, TPE . . . . . . . . . . . . . . . . . . . . . . 10
CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
MAXA and MAXANA. . . . . . . . . . . . . . . . . . . . . . 18
CRE, CRIE, CRNE. . . . . . . . . . . . . . . . . . . . . . . . . 17
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CV, CPV, CPH . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
NBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Delta Control 2000. . . . . . . . . . . . . . . . . . . . . . . 11
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
DME, DMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
NKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
NM, NP, DNM, DNP . . . . . . . . . . . . . . . . . . . . . . 11
GRUNDFOS ALPHA+ UPS, UP Series 100 . . . . . . . . . .8
S pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
GRUNDFOS COMFORT UP-N, UP(S)-B Series 100 . . . . .8
SRP pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
LM, LP, CLM . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
SEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
LME, LPE, CLME, TPE . . . . . . . . . . . . . . . . . . . . . . 10
SE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SIPLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SPK, CHK, MTH, CRK, MTR, MTA . . . . . . . . . . . . . . . 13
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SPKE, CRKE. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
NKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Pressure tanks . . . . . . . . . . . . . . . . . . . . . . . . . 25
NM, NP, DNM, DNP . . . . . . . . . . . . . . . . . . . . . . 11
TP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
TPE Series 2000 . . . . . . . . . . . . . . . . . . . . . . . . . 10
UPS Series 200 . . . . . . . . . . . . . . . . . . . . . . . . . .8

6
GRUNDFOS

Product and application overview

Pressure boosting and liquid transfer SQ, SQE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21


BM, BMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Pressure tanks . . . . . . . . . . . . . . . . . . . . . . . . . .25
BME, BMET . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
CH, CHN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Sewage and wastewater
CHI, CHIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
AMD, AMG, AFG . . . . . . . . . . . . . . . . . . . . . . . . 26
CHIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CHI, CHIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CHV booster . . . . . . . . . . . . . . . . . . . . . . . . . . .25
CHIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CHV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
DME, DMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Control 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . 19
DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
CR, CRI, CRN. . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
DP, EF, SE1 and SEV. . . . . . . . . . . . . . . . . . . . . . . 29
CR, CRN high pressure . . . . . . . . . . . . . . . . . . . . 16
DW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . . . . . . . . 17
KP, AP, AP35B, AP50B - stainless steel . . . . . . . . . . . 26
CRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Lifting stations . . . . . . . . . . . . . . . . . . . . . . . . . .27
CV, CPV, CPH . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Sololift+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
GP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
S pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Hydro 2000, Hydro 1000, Hydro Solo, Hydro Multi-E . 19
SRP pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
LM, LP, CLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SEG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
LME, LPE, CLME, TPE . . . . . . . . . . . . . . . . . . . . . . 10
SEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
MQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
SE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
NBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Environmental applications
NKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 CR, CRI, CRN. . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
NM, NP, DNM, DNP . . . . . . . . . . . . . . . . . . . . . . . 11 CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . . . . . . . . 17
CRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
DME, DMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Groundwater supply DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
DME, DMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
MP 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
SQE-NE, SP-NE . . . . . . . . . . . . . . . . . . . . . . . . . .22
SP A, SP, SP-G . . . . . . . . . . . . . . . . . . . . . . . . . . .21
SQ, SQE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Pressure tanks . . . . . . . . . . . . . . . . . . . . . . . . . .25 Dosing
DME, DMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Domestic water supply
CH, CHN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
CHV booster . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Renewable-energy systems
CHV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 SQFlex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
CR, CRI, CRN. . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . . . . . . . . 17
DME, DMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Hydro 2000, Hydro 1000, Hydro Solo, Hydro Multi-E . 19
JP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
MQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
RMQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
SP A, SP, SP-G . . . . . . . . . . . . . . . . . . . . . . . . . . .21

7
GRUNDFOS ALPHA+ GRUNDFOS COMFORT UPS Series 200
UPS, UP Series 100 UP-N, UP(S)-B Series 100
Circulator pumps, canned-rotor type Circulator pumps, canned-rotor type Circulator pumps, canned-rotor type

H [m] H [m]
10.0 8.0
6.0 4.0
4.0
2.0
Series 100
2.0 UP-N, UP(S)-B Series 100
ALPHA+ 1.0
1.0
0.4 COMFORT
0.4 0.2
0.2 0.1
0.4
0 1 2 4 6 10 15 0.1
0 0.2 0.5 1 2 4 6 10
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 10 m3/h Flow, Q: max. 10.5 m3/h Flow, Q: max. 70 m3/h
Head, H: max. 12 m Head, H: max. 7 m Head, H: max. 18 m
Liquid temp.: –25°C to +110°C Liquid temp.: –25°C to +110°C Liquid temp.: –10°C to +120°C
Operat. pres.: max. 10 bar Operat. pres.: max. 10 bar Operat. pres.: max. 10 bar

Applications Applications Applications


Circulation of hot or cold water in Circulation of hot or cold water in Circulation of hot or cold water in
• Heating systems • Domestic hot water recirculation • Heating systems
• Domestic hot water systems • Heating systems • Domestic hot water systems
• Cooling and air-conditioning systems • Domestic hot water systems • Cooling and air-conditioning systems
• Features and benefits • Cooling and air-conditioning systems
• Maintenance-free Features and benefits
• Low-noise Features and benefits • Maintenance-free
• Low-energy
• Maintenance-free • Built-in thermal switch
• Wide range
• Low-noise • Low-noise
• Low-energy • Low-energy
Options • Wide range • Single-phase with built-in protection
• Automatic performance adjustment • Corrosion-resistant stainless steel, module
• Simple installation - external plug for brass pump housing • Wide range
electrical connection
• Single-speed or 2- or 3-speed Options Options
performance adjustment
• 24-hour timer • Protection module
• Twin-head versions
• Adjustable thermostat • Relay module with fault signal or
operating output
• Bronze pump housing
• Twin-head versions
• Communication via GENIbus or LON

8
GRUNDFOS

GRUNDFOS MAGNA, TP LM, LP, CLM


UPE Series 2000
Circulator pumps, canned-rotor type Circulator pumps, close-coupled type Single-stage centrifugal pumps
- electronically controlled

H [m]
200
100
50

20
10
5
10 40 100 200400 1000 4000
Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 90 m3/h Flow, Q: max. 4600 m3/h Flow, Q: max. 600 m3/h
Head, H: max. 12 m Head, H: max. 170 m Head, H: max. 60 m
Liquid temp.: +15°C to +110°C Liquid temp.: –25°C to +150°C Liquid temp.: –40°C to +140°C
Operat. pres.: max. 10 bar Operat. pres.: max. 25 bar Operat. pres.: max. 20 bar

Applications Applications Applications


Circulation of hot water in Circulation of hot or cold water in The pumps are suitable for liquid transfer
• Heating systems in blocks of flats, • Heating systems in
schools, hospitals, hotels, industry etc. • District heating plants • District heating plants
• Local heating plants • Cooling and air-conditioning systems
Features and benefits • Domestic hot water systems • Industrial plants
• Cooling and air-conditioning systems
• Low-noise
• Low-energy Features and benefits
• Wide range Features and benefits • Adaptable to any application and
• Automatic performance adjustment • Compact design performance
• Simple installation - no extra • Wide range • EN 12 756 shaft seal
equipment or fittings required • Standard motor • Wide range
• Safe selection • Service-friendly • Standard motor
• Various types of shaft seals depending • Service-friendly
Options on liquid, temperature and pressure
• Stainless steel pump housing Options
• Twin-head versions Options • Various types of shaft seals depending
• Wireless remote control, R100 • Bronze pump housing on liquid, temperature and pressure
• Communication via GENIbus or LON • Twin-head versions • Twin-head versions
• Bronze impeller (CLM only)

9
TPE Series 2000 LME, LPE, CLME, TPE R100

Single-stage, centrifugal pumps - Single-stage, centrifugal pumps - Wireless remote control


electronically controlled electronically controlled

Applications
• All pumps designed for wireless
communication

Features and benefits


• Simple and quick installation of the
pump
• Reading out of various operating and
fault signals
• Printing out of status information

Technical data Technical data


Flow, Q: max. 130 m3/h Flow, Q: max. 160 m3/h
Head, H: max. 28 m Head, H: max. 60 m
Liquid temp.: –25°C to +140°C Liquid temp.: –25°C to +140°C
Operat. pres.: max. 16 bar Operat. pres.: max. 16 bar

Applications Applications
Circulation of hot or cold water in The pumps are suitable for liquid transfer
• Heating systems in
• Domestic hot water systems • District heating plants
• Cooling and air-conditioning systems • Cooling and air-conditioning systems
• Industrial plants
Features and benefits
• Low-energy Features and benefits
• Adaptation to existing operating • Low-energy
conditions • Adaptation to existing operating
• Simple installation conditions
• Simple installation
Options • Many control facilities
• Wireless remote control, R100
• Parallel operation
• Communication via GENIbus or LON
• Wireless remote control, R100
• Communication via GENIbus or LON
• Twin-head versions

10
GRUNDFOS

PMU 2000, PCU 2000 Delta Control 2000 NM, NP, DNM, DNP

Pump controllers Pump controllers Single-stage standard pumps

Applications Technical data


No. of pumps: max. 4
PMU 2000 Power output: 75 kW
• Parallel connection of up to eight pumps Encl. class: IP 54
• Central reading out of various status
information Applications
Delta Control 2000 are used for parallel
PCU 2000 connection of pumps in
• Fault indication for each pump • Heating systems
• Cooling and air-conditioning systems
• External setpoint influence
• Start/stop of system
Technical data
Features and benefits
• Complete control panel Flow, Q: max. 160 m3/h
Features and benefits
Head, H: max. 62 m
• Communication via BUS Liquid temp.: –25°C to +140°C
• Simple and quick installation Options
Operat. pres.: max. 16 bar
• External communication

Applications
The pumps are suitable for liquid transfer
in
• Washing systems
• District heating plants
• Cooling and air-conditioning systems
• Industrial plants

Features and benefits


• Standard dimensions according to ISO or
DIN standards
• Compact design
• Flexible pump range
• Standard motor
• Adaptable to any application and
performance
• EN 12 756 shaft seal

Options
• Various types of shaft seal depending on
liquid, temperature and pressure

11
NB, NBG NK, NKG NBE

Single-stage standard pumps Single-stage standard pumps Single-stage standard pumps -


electronically controlled

H [m]
100
60
40

20

10
6
4
10 20 30 60 100 200300 500
Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 460 m3/h Flow, Q: max. 2000 m3/h Flow, Q: max. 189 m3/h
Head, H: max. 96 m Head, H: max. 150 m Head, H: max. 58 m
Liquid temp.: –25°C to +140°C Liquid temp.: –25°C to +140°C Liquid temp.: –25°C to +140°C
Operat. pres.: max. 16 bar Operat. pres.: max. 16 bar Operat. pres.: max. 16 bar

Applications Applications Applications


The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer
in in in
• District heating plants • District heating plants • Washing systems
• Heating systems for blocks of flats • Water supply systems • Water supply systems
• Air-conditioning systems • Air-conditioning systems • District heating plants
• Cooling systems • Cooling plants • Cooling and air-conditioning systems
• Washdown systems • Industry • Industrial plants
• Other industrial systems • Fire fighting systems
• Environment engineering Features and benefits
Features and benefits • Standard dimensions according to EN
• Standard dimensions according to EN Features and benefits standards
and ISO standards • Standard dimensions according to EN or • Compact design
• Compact design ISO standards • Adaptable to any application and
• Flexible pump range • Wide range performance
• Standard motor • Robust design • EN 12 756 shaft seal
• Adaptable to any application and • Heavy-duty • Many control facilities
performance • Flexible motor range
• EN 12 756 shaft seal Optional
• Various types of shaft seal depending on
Optional liquid, temperature and pressure
• Various types of shaft seal depending on • Cast iron or bronze impeller
liquid, temperature and pressure • Wireless remote control, R100
• Cast iron or bronze impeller

12
GRUNDFOS

NKE SPK, CHK, MTH, CRK, MTR, SPKE, CRKE


MTA
Single-stage standard pumps - Multistage centrifugal immersible pumps Multistage centrifugal immersible pumps -
electronically controlled electronically controlled

Technical data Technical data Technical data


Flow, Q: max. 190 m3/h Flow, Q: max. 85 m3/h Flow, Q: max. 22 m3/h
Head, H: max. 59 m Head, H: max. 238 m Head, H: max. 245 m
Liquid temp.: –25°C to + 140°C Liquid temp.: –20°C to + 90°C Liquid temp.: –10°C to + 90°C
Operat. pres.: max. 16 bar Operat. pres.: max. 25 bar Operat. pres.: max. 25 bar

Applications Applications Applications


The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer The pumps are suitable for
in in • Boiler feeding systems
• Washing systems • Spark machine tools • Pumping of cooling lubricants
• Water supply systems • Grinding machines • Water treatment systems
• District heating plants • Machining centres
• Cooling and air-conditioning systems • Cooling units Features and benefits
• Industrial plants • Industrial washing machines • Wide range
• Filtering systems
• Reliability
Features and benefits • Lathes
• Wireless remote control, R100
• Standard dimensions according to DIN • Swarf conveyors
standards
• Wide range Features and benefits
• Robust design • Flexible installation length
• Heavy-duty • Wide range
• Many control facilities • Reliability
• Service-friendly
Options • Simple installation
• Wireless remote control, R100

13
DME, DMS DMM GP

Compact diaphragm dosing pumps Motor-driven diaphragm dosing pumps Swimming-pool pumps

p [bar]
20

10
6
4

1
1 2.5 10 40 100 375 1000
Q [l/h]

Technical data Technical data Technical data


Capacity, Q: max. 940 l/h Capacity, Q: max. 990 l/h Flow, Q: max. 26 m3/h
Pressure, p: max. 18 bar Pressure, p: max. 10 bar Head, H: max. 17.5 m
Liquid temp.: max. +50°C Liquid temp.: max. +50°C Liquid temp.: 0°C to +40°C
Operat. pres.: max. 3 bar

Applications Applications Applications


Injection of chemicals in water and waste Injection of chemicals in water and waste The pumps are suitable for
water treatment systems, washing sys- water treatment systems, washing sys- • Circulation of swimming-pool water in
tems, swimming-pools and process plants tems, swimming-pools and process plants small and medium sized swimming-
pools
Features and benefits Features and benefits
• Precise capacity setting directly in ml or l • Sturdy design Features and benefits
• Full diaphragm control • Stroke length capacity control • Built-in motor protection
• Stroke speed or -frequency capacity • Leakage-free • Stainless steel shaft
control • Motor control option with display and • Low sound level
• Operation panel with display and one- one-touch buttons and following • Self-priming down to 2 m
touch buttons control options: • Corrosion resistant materials
• Front- or side-fitted operation panel – Pulse control • No need for special service tools
• Manual/pulse control – Puls division/multiplication • Quick and easy to repair
• Control panel lock – Analog 0/4-20 mA control
• 4-20 mA control
Options
• Pulse-/timer-based batch control
• Anti-cavitation function • Integrated heating unit
• Easy calibration function • Level sensor
• Fieldbus communication module • Control panels
(option)
• Leakage sensor

14
GRUNDFOS

CHI, CHIU CHIE CR, CRI, CRN

Multistage centrifugal pumps Multistage centrifugal pumps - Multistage centrifugal pumps


electronically controlled

H [m] H [m]
60
40 200
150
20
100
10
6 60
4
40
2
1 20
1 2 4 6 8 10 15 20 1 2 4 6 10 20 40 100 200
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 14 m3/h Flow, Q: max. 14 m3/h Flow, Q: max. 120 m3/h
Head, H: max. 57 m Head, H: max. 58 m Head, H: max. 330 m
Liquid temp.: –15°C to +120°C Liquid temp.: –15°C to +110°C Liquid temp.: –40°C to +180°C
Operat. pres.: max. 10 bar Operat. pres.: max. 10 bar Operat. pres.: max. 33 bar

Applications Applications Applications


The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer
in in in
• Water treatment systems • Cooling systems • Washing systems
• Industrial washing and dishwashing • Industrial washing systems • Cooling and air-conditioning systems
machines • Aquafarms • Water supply systems
• Pressure boosting of process water • Fertilizer systems • Water treatment systems
• Heating and cooling in industrial • Dosing systems • Fire fighting systems
processes • Industrial plants • Industrial plants
• Air-conditioning systems • Boiler feeding systems
• Airwashing, moisturization, Features and benefits
humidification (softened water) Features and benefits
• Compact design
• Water supply and pressure boosting
• Wide range • Reliability
(potable water, also slightly chlorinated) • Suitable for slightly aggressive liquids • High efficiency
• Many control facilities • Service-friendly
Features and benefits • Space-saving
• Compact design Options • Suitable for slightly aggressive liquids
• Wide range
• Wireless remote control, R100
• Suitable for slightly aggressive liquids Options
• Low noise
• Dry-running protection and motor
• Leakage-free (CHIU only)
protection via LiqTec

15
CR, CRN high pressure CRT LiqTec

Multistage centrifugal pumps Multistage centrifugal pumps Control and monitoring unit

H [m] H [m]
Applications
400 200 • Monitoring and protection of pumps
200 and processes
100
100
60 Features and benefits
60 • Protection against dry running
40
40 • Protection against liquid temperatures
20 20 exceeding 130°C ±5°C
1 2 4 6 10 20 40 100 200 1 2 4 6 8 10 20 30 • Protection against too high motor
Q [m³/h] Q [m³/h] temperatures
• Manual or automatic restarting possible
Technical data Technical data from a remote PC
Flow, Q: max. 120 m3/h Flow, Q: max. 22 m3/h • Simple installation - plug and play
Head, H: max. 480 m Head, H: max. 250 m technology
Liquid temp.: –30°C to +120°C Liquid temp.: –20°C to +120°C • Robust sensor
Operat. pres.: max. 50 bar Operat. pres.: max. 25 bar

Applications Applications
The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer
in in
• Washing systems • Process water systems
• Water treatment systems • Washing in cleaning systems
• Industrial plants • Sea water systems
• Boiler feeding systems • Pumping of acids and alkalis
• Ultra filtration systems
Features and benefits • Reverse osmosis systems
• Swimming baths
• Reliability
• High pressures
• Service-friendly Features and benefits
• Space-saving • High corrosion resistance
• Suitable for slightly aggressive liquids • Reliability
• Single pump solution enabling high • High efficiency
pressure • Service-friendly
• Space-saving
Options
• Dry-running protection and motor Options
protection via LiqTec • Dry-running protection and motor
protection via LiqTec

16
GRUNDFOS

CV, CPV, CPH CRE, CRIE, CRNE Euro-HYGIA®

Multistage centrifugal pumps Multistage centrifugal pumps - Single-stage, end-suction sanitary pumps
electronically controlled

H [m] H [m]
200 100
100 60
40
40
20 20
10 10
4 6
2 4
2 4 6 10 20 40 60 100 10 15 20 30 40 60 100 150
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 560 m3/h Flow, Q: max. 120 m3/h Flow, Q: max. 130 m3/h
Head, H: max. 200 m Head, H: max. 250 m Head, H: max. 75 m
Liquid temp.: –15°C to +120°C Liquid temp.: –40°C to +180°C Operat. temp.: +95°C
Operat. pres.: max. 20 bar Operat. pres.: max. 33 bar (+150°C on request)
Operat. pres.: max. 16 bar
Applications Applications
The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer Applications
in in • Liquid transfer in breweries and dairies
• Washing systems • Washing systems • Mixing in soft drink applications
• Cooling and air-conditioning systems • Cooling and air-conditioning systems • Food processing plants
• Water supply systems • Water supply systems • Pure water systems (WFI)
• Water treatment systems • Water treatment systems • Process pumping in pharmaceutical
• Fire fighting systems • Fire fighting systems industry
• Industrial plants • Industrial plants • CIP (Cleaning-In-Place) systems.
• Boiler feeding systems • Boiler feeding systems
Features and benefits
Features and benefits Features and benefits • Unique hygienic design (QHD, EHEDG
• Low-speed (4-pole motors) • Wide range and 3A standards)
• Heavy-duty • Reliability • CIP and SIP capable (DIN EN 12462)
• Low-noise • In-line design • Customised solutions
• Vertical and horizontal installation • High efficiency • Materials: AISI 316L (DIN EN 1.4404/
• Service-friendly 1.4435)
• Space-saving • Gentle media handling.
• Many control facilities
Options
Options • Electronically speed controlled versions
• Wireless remote control, R100 • ATEX-certified pumps
• Wide range impeller designs.

17
Contra SIPLA MAXA and MAXANA

Single- and multi-stage, end-suction sani- Single-stage, self-priming side-channel End-suction process pumps
tary pumps sanitary pumps

H [m] H [m] H [m]


150 60 100
100 40 60
30 40
60
30
40 20
20

20 10 10

10 5 5
5 10 15 20 30 40 60 5 10 20 30 40 60 100 20 40 60 100 200 400 1000
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 55 m3/h Flow, Q: max. 90 m3/h Flow, Q: up to max. 800 m3/h
Head, H: max. 170 m Head, H: max. 50 m Head, H: up to max. 97 m
Operat. temp.: +95°C Operat. temp.: +95°C Operat. temp.: +95°C
(+150°C on request) (+140°C on request) (+150°C on request)
Operat. pres.: max. 25 bar Operat. pres.: max. 10 bar Operat. pres.: max. 10 bar

Applications Applications Applications


• Liquid transfer in breweries and dairies • CIP return pumping • Gentle pumping of mash and wort for
• Carbonising systems • Transfer of glycerine beer filtration (hot side)
• Food processing plants • Transfer of yeast • Liquid transfer in dairies
• Purification systems • Transfer of whey. • Water treatment plants
• Pure water systems (WFI) • Chemical and environmental handling
• Surface treatment systems Features and benefits systems
• CIP feeding systems. • Liquids with high content of solid parti-
• Meets the 3A hygienic standard
cles.
• High air-content handling
Features and benefits • Efficient priming.
• Unique hygienic design (QHD, EHEDG Features and benefits
and 3A standards) Options • Optimised hydraulics
• CIP and SIP capable (DIN EN 12462) • Gentle product handling
• Electronically speed controlled versions
• High efficiency • Materials: AISI 316 (DIN EN 1.4404)
• ATEX-certified pumps
• Materials: AISI 316L (DIN EN 1.4404/ • Fully cleanable versions. • Service and repair friendly.
1.4435).
Options
Options • Electronically speed controlled versions
• Electronically speed controlled versions • ATEX-certified pumps
• ATEX-certified pumps • Electro-polished versions
• Fully drainable versions. • Double mechanical shaft seals (tandem/
back-to-back).

18
GRUNDFOS

Hydro 2000, Hydro 1000, Control 2000 BMP


Hydro Solo, Hydro Multi-E
Complete pressure boosting systems Pump controllers Piston pumps designed for transport of
fluids under high pressure.

Applications Technical data


Control 2000 is suitable for parallel Flow, Q: max. 10.2 m3/h
connection of pumps in Head, H: max. 1630 m
• Water supply systems Liquid temp.: 3°C to +50°C
• Irrigation systems Operat. pres.: max. 160 bar
• Water treatment systems
• Fire fighting systems Applications
• Industrial plants
BMP pumps are suitable for a variety of
applications ranging from pumping of
Features and benefits potable water to pumping of chemicals.
• Complete control panel • Cleaning/washing
Technical data • Injecting
Flow, Q: max. 720 m3/h Options • Misting
Head, H: max. 160 m • External communication • Processing
Liquid temp.: 0°C to +70°C • Desalination of brackish water and
Operat. pres.: max. 16 bar seawater

Applications Features and benefits


Hydro 2000 are suitable for pressure • High efficiency
boosting in • Small and light pump
• Water supply systems • Generates insignificant pulsations in the
• Irrigation systems discharge line
• Water treatment systems • No preventive maintenance required
• Fire fighting systems • Long service life
• Industrial plants • Few wear parts
• Wide speed control range
• Extreme recirculation capability without
Features and benefits
overheating (up to 90%)
• Constant pressure
• Lubricated by the pumped liquid
• Simple installation
• Low-energy
• Wide range

Options
• External communication, Control 2000

19
BM, BMB BME, BMET BMEX

4", 6", 8" booster modules High-pressure booster systems Grundfos booster system BMEX is designed
for energy recovery in Sea Water Reverse
Osmosis (SWRO)

H [m] [kWh]
BMEX / BMET
400 5.0

4.5

BMET
200 4.0

3.5

100 3.0

60 2.5

40 2.0
BMEX / BMET
1.5 BMEX

20 1.0

0.5

10 0.0

1 2 4 10 20 40 100 200 400 0 200 400 600 800 1000 1200 1400
Permeate
1600 1800 2000 2200 2400 2600 2800
Q [m³/day]

Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 260 m3/h Flow, Q: max. 95 m3/h Permeate per day: 500 to 2500 m3
Head, H: max. 430 m Head, H: max. 700 m Head, H: max. 810 m
Liquid temp.: 0°C to +40°C Liquid temp.: 0°C to +40°C Ambient temp.: +40°C
Operat. pres.: max. 80 bar Operat. pres.: max. 70 bar Operat. pres.: max. 80 bar

Applications Applications Applications


The booster modules are suitable for The booster systems are suitable for • Desalination of brakish water and
pressure boosting in pressure boosting in seawater
• Reverse osmosis systems • Reverse osmosis systems
• Water supply systems • Water supply systems Features and benefits
• Water treatment systems • Water treatment systems
• Energy recovery up to 60%, compared to
• Industrial plants • Industrial plants
conventional systems, resulting in short
payback period
Features and benefits Features and benefits • Corrosion- and wear-resistant internal
• Various material versions • High-pressure/high-flow ceramic com-ponents
• Low-noise • Low-energy • Couplings for easy installation
• Simple installation • Simple installation • High-grade stainless steel used on frame
• Modular design • Compact design and manifold
• Compact design • Large flows and high heads
• Leakage-free • Motor and bearings are standard com-
ponents
• Maintenance-free shaft seal
• V-belt drive with high efficiency
• Easy to dismantle for service

20
GRUNDFOS

SQ, SQE SP A, SP, SP-G MS motors

3" submersible pumps 4", 6", 8", 10", 12" submersible pumps Stainless steel 4" and 6" submersible
motors

H [m]
600 Motor sizes
400 4" motor: 0.37 to 7.5 kW
200 6" motor: 5.5 to 30 kW
100
60 Applications
40 The Grundfos MS submersible motors can
20 be fitted on all Grundfos SP A, SP pumps
10 and can be used in the high-pressure
1 2 4 10 20 40 100 200 600 booster modules, type BM and BMB.
Q [m³/h]

Features and benefits


Technical data Technical data
• Overprotection by means of a built-in
Flow, Q: max. 9 m3/h Flow, Q: max. 470 m3/h Tempcon temperature transmitter
Head, H: max. 210 m Head, H: max. 670 m • Standardized NEMA head and shaft end
Liquid temp.: 0°C to +40°C Liquid temp.: 0°C to +60°C • Completely encapsulated in stainless
Installation depth: max. 150 m Installation depth: max. 600 m steel
• Liquid cooled and has liquid lubricated
Applications Applications bearings
The pumps are suitable for The pumps are suitable for
• Domestic water supply systems • Groundwater supply to waterworks Options
• Groundwater supply to waterworks • Irrigation in horticulture and agriculture • Material variants available
• Irrigation in horticulture and agriculture • Groundwater lowering
• Groundwater lowering • Pressure boosting
• Industrial applications • Industrial applications

Features and benefits Features and benefits


• Integrated dry-running protection • High efficiency
• Soft start • Long service life as all components are
• Over- and undervoltage protection stainless steel
• High efficiency • Motor protection via CU 3

Options Options
• SQE can be protected, monitored and • Data can be monitored and controlled
controlled by CU 300 and CU 301 via via CU 3/R100
R100.

21
MMS motors SQE-NE, SP-NE MP 1

Stainless steel 6", 8", 10", 12" rewindable Environmental pumps Environmental pumps
submersible motors

Motor sizes
6" motor: 3.7 to 37 kW
8" motor: 22 to 110 kW
10" motor: 75 to 190 kW
12" motor: 147 to 250 kW

Applications
The Grundfos MMS submersible motors
can be fitted on all Grundfos SP and SP-G
pumps.

Technical data Technical data


Features and benefits
• Wide range of rewindable motors Flow, Q: max. 22 m3/h Flow, Q: max. 2.4 m3/h
• Easily rewinded Head, H: max. 215 m Head, H: max. 95 m
• Protection against upthrust Liquid temp.: 0°C to +40°C Liquid temp.: 0°C to +35°C
• High efficiency Instal. depth: max. 600 m
• 6" and 8" have standardized NEMA head
and shaft end Applications Applications
• Mechanical shaft seal The pumps are suitable for The pumps are suitable for
ceramic/carbon or SiC/SiC • Pumping up contaminated groundwater • Sampling
• PVC or PE/PA windings • Sampling
• Remedial pumping Features and benefits
Options • Compact design
• Material variants available Features and benefits • Fit into 50 mm boreholes
• Overtemperature protection via Pt100 SQE-NE
• Same features and benefits as SQE
SP-NE
• Same features and benefits as SP

22
GRUNDFOS

SQFlex CU 3, CU 300, CU 301 JP

Renewable-energy based water supply Control and monitoring units Self-priming jet pumps
systems

H [m]
140 Applications
120 • Monitoring and protection of pump
100 installations
80
60 Features and benefits
40 • Protection against dry running and too
20 high motor temperature
• Constant monitoring of pump energy
0
0 20 40 60 80 100 consumption
Q [m³/day] • Reading out of operating data via R100

Technical data Technical data


Options
Flow, Q: max. 90 m3/day • Connection to large control systems via Flow, Q: max. 5 m3/h
Head, H: max. 120 m BUS-communication Head, H: max. 48 m
Liquid temp.: 0°C to +40°C • Connection of sensors enabling control Liquid temp.: 0°C to +55°C
Voltage supply: 30-300 VDC or based on sensor signals Operat. pres.: max. 6 bar
1x90-240 V, 50/60 Hz
Instal. depth: max. 150 m Applications
The pumps are suitable for liquid transfer
Applications in
The SQFlex systems are suitable for remote • Households
locations, such as: • Gardens
• Villages, schools, hospitals, single-family • Hobby activities
houses • Agriculture
• Farms and irrigation of greenhouses • Horticulture
• Game parks and game farms • Small industries
• Conservation areas
Features and benefits
Features and benefits • Self-priming
• Energy supply: Solar modules, wind • Stable operation even in case of air
turbine, generator or batteries pockets in the liquid
• Simple installation
• Reliable water supply Options
• Virtually no maintenance
• Automatic start/stop when equipped
• Expansion possibilities
with Presscontrol
• Cost-efficient pumping • Booster sets for small-scale water supply
• Dry-running protection

23
CH, CHN MQ RMQ

Multistage centrifugal pumps Multistage centrifugal self-priming pumps Rainwater unit for monitoring and control
of rainwater systems

Technical data Technical data Technical data


Flow, Q: max. 14 m3/h Flow, Q: max. 5 m3/h Flow, Q: max. 5 m3/h
Head, H: max. 55 m Head, H: max. 48 m Head, H: max. 48 m
Liquid temp.: 0°C to +90°C Liquid temp.: 0°C to +35°C Liquid temp.: 0°C to +35°C
Operat. pres.: max. 10 bar Operat. pres.: max. 7.5 bar Operat. pres.: max. 7.5 bar

Applications Applications Applications


The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer The rainwater unit is suitable for the
in in transfer of water from water collection and
• Pressure boosting systems • Single- or two-family houses utilisation systems in:
• Domestic water supply systems • Weekend cottages • Single- or two-family houses
• Cooling systems • Farms • Weekend cottages
• Air-conditioning systems • Greenhouses • Farms
• Horticultural irrigation systems • Gardens and greenhouses
• Small industrial water supply systems Features and benefits
• All-in-one pressure booster unit Features and benefits
Features and benefits • Easy to install • Automatic changeover between rain-
• Compact design • Easy to operate water tank and integrated main water
• Robust design • Self-priming tank
• Full stainless steel design (CHN only) • Dry-running protection with automatic • Manual changeover between rainwater
• Low-noise reset tank and integrated main water tank
• Low-noise • Acoustic/visual alarm in case of over-
Options • Maintenance-free flow in integrated main water tank
• Booster sets for domestic water supply
• Automatic start/stop when equipped Options
with Presscontrol • Control of additional booster pump
• Backflow sensor in case of overflow in
sewers

24
GRUNDFOS

CHV CHV booster Pressure tanks

Multistage centrifugal pumps Vertical pressure booster systems Diaphragm and bladder tanks

Technical data
Tank size: 8-3000 l
Liquid temp.: max. +90°C
Operat. pres.: max. 16 bar

Applications
The diaphragm and bladder tanks are used
in
• Water supply systems in housing
• Pressure boosting systems in housing
Technical data Technical data • Agriculture
Flow, Q: max. 8 m3/h Flow, Q: max. 16 m3/h • Horticulture
Head, H: max. 93 m Head, H: max. 93 m • Industrial systems
Liquid temp.: 0°C to +90°C Liquid temp.: 0°C to +40°C
Operat. pres.: max. 12 bar Operat. pres.: max. 10 bar Features and benefits
• Optimal water supply
Applications Applications • Reduced number of pump starts
The pumps are suitable for liquid transfer The booster systems are suitable for • Ideal for drinking water
in pressure boosting in
• Pressure boosting systems • Small waterworks
• Domestic water supply systems • Small blocks of flats
• Cooling systems • Hotels
• Air-conditioning systems • Stores
• Horticultural irrigation systems • Light industry
• Small industrial water supply systems • Hospitals
• Schools
Features and benefits • Large houses
• Compact design
• Robust design Features and benefits
• Low-noise • One- or two-pump system
• Space-saving • User-friendly controllers
• Reliability
• High efficiency
• Service-friendly

Options
• Overpressure protection
• Dry-running protection

25
KP, AP, AP35B, AP50B SEG AMD, AMG, AFG
- stainless steel
Drainage pumps Grinder pumps Mixers and flowmakers

Technical data
Liquid temp.: +5°C to +40°C
pH value: 4 to 10
Axial thrust: 160 to 3931 N
Max. dynamic
viscosity: 500 mPa s
Max. density: 1060 kg/m3
Max. installation
depth: 30 m

Applications
Technical data Technical data The mixers and flowmakers are designed
Flow, Q: max. 35 m3/h Flow, Q: max. 5 l/s for mixing, i.e. homogenization and
Head, H: max. 18 m Head, H: max. 47 m suspension, of liquids in
Liquid temp.: 0°C to +55°C Liquid temp.: 0°C to +40°C • Municipal wastewater treatment
Particle size: max. ø50 mm systems
• Industrial processes
Applications Applications • Sludge treatment systems
The pumps are suitable for The pumps are suitable for the pumping of • Agriculture
• Drainage of flooded cellars wastewater and sewage through pipes of • Biogas plant
• Pumping of household wastewater 40 mm in diameter and upwards. The mixers and flowmakers are equipped
• Groundwater lowering with propellers made of stainless steel or
• Emptying of swimming-pools and Features and benefits composite material with a diameter
excavations between 180 mm and 2300 mm and a
• Service-friendly
• Drainage of drain wells rotation speed between 22 min-1 and
• Installation on foot or auto-coupling
• Emptying of tanks and reservoirs 1400 min-1.
• Continuous operation with fully sub-
merged pump
Features and benefits • Built-in motor protection Features and benefits
• Simple installation • SmartTrim • Angular contact bearings
• Service- and maintenance-free • Improved grinder system (roller bearings)
• Totally sealed cable plug • Easy to maintain and service without
use of special tools
Options • Electronic leak sensor in gearbox/shaft
• AP35B and AP50B are suitable for Options
seal housing
installation on auto-coupling • Wide range of accessories
• Shaft seal protected against abrasive
• Monitoring and control of one or several
materials
pumps
• Self-cleaning stainless steel or
polyamide propellers

26
GRUNDFOS

DW Lifting stations Sololift+

Contractor pumps Complete pumping stations Small lifting stations

H [m] H [m]
Applications
100 30 Sololift+ can be used for :
60
20 • extra bathrooms
40
• basement installations
20 • low-cost bathrooms in holiday cottages
10
• added facilities in hotels and guest-
10
6 houses
• bathrooms for the elderly or the disabled
4 4 • renovation of offices and other commer-
1 2 4 10 20 40 100 400 1 10 20 30 50
Q [m³/h] Q [l/s] cial buildings.

Technical data Technical data Features and benefits


Flow, Q: max. 300 m3/h Flow, Q: max. 60 l/s (216 m3/h), • Unique design with smooth line and
Head, H: max. 100 m recom. 31 l/s (110 m3/h) rounded edges - fits every modern
Liquid temp.: 0°C to +40°C Head, H: max. 29 m bathroom environment
Liquid temp.: 0°C to +40°C • Plug-and-go product - all you need in
Discharge diameter: DN 80 to DN 100 one package
• Low noise level
Applications
• Discharge pipe connection in the side
The pumps are suitable for liquid transfer Applications ensures easy maintenance
in The lifting stations are suitable for use in • Flexible discharge pipe adapters for
• Tunnels • Single- and multi-family houses outer pipe diameters of ø23, ø25, ø28
• Mines • Weekend cottages and summer houses and ø32 mm
• Quarries • Restaurants • Thermal overload switch
• Gravel pits • Small hotels • Cover without screws - easy service
• Fish ponds • Sewage systems in the open country • Easy connection of extra sanitary appli-
• Building sites • Percolation systems ances

Features and benefits Features and benefits CWC-3


• Extremely hard-wearing due to specially • Ready for installation • Especially designed for wall-hung toilets
selected materials • Flexible pipe connection • Compact and slim for easy integration
• Simple installation • Cable plug connection into the wall
• Service-friendly • Unique clamp assembly system
• Single-channel and vortex impellers
C-3
• Solids passage up to 100 mm
• Low risk of clogging • Especially designed for high liquid tem-
• Minimum downtime perature wastewater from washing
• Low operating costs machine or dishwasher
• Liquidless motor cooling • Compact and slim for easy installation
• Unique cartridge shaft seal under a washbasin or in a closet
• Modular design

27
S pumps SRP pumps SEN

Supervortex pumps, single- or Submersible re-circulation pumps Submersible stainless steel pumps
multichannel impeller pumps

H [m] H [m] H [m]


60
100 2.0
1.5 40
60 30
40 1.0
0.8 20
DN 300 DN 500 DN 800
20 0.6
10
10 0.4
0.3 6
6
4 0.2 4
10 20 40 100 200 400 1000 3000 100 200 400 600 1000 2000 10 20 30 50 100 200 300
Q [l/s] Q [l/s] Q [l/s]

Technical data Technical data Technical data


Flow, Q: max. 2500 l/s Flow, Q: max. 1300 l/s Flow, Q: max. 215 l/s
Head, H: max. 116 m (4680 m3/h) (774 m3/h)
Liquid temp.: 0°C to +40°C Head, H: max. 1.8 m Head, H: max. 50 m
Discharge diameter: DN 80 to DN 500 Liquid temp.: 5°C to +40°C Liquid temp.: 0°C to +40°C
Particle size: max. ø145 mm Column pipe Discharge diameter: DN 80 to DN 250
diameter: DN300, DN500 and DN800
Applications Applications
The pumps are suitable for the following Applications The pumps are suitable for the following
applications The pumps are suitable for the following applications
• Transfer of wastewater applications • Transfer of wastewater and raw water
• Transfer of raw water • Transfer of raw water • Pumping of highly aggressive liquids
• Pumping of sludge-containing water • Re-circulation of sludge within sewage • Pulp and paper industries
• Pumping of industrial effluent treatment plants
• Storm water pumping Features and benefits
Features and benefits • Irrigation
• SmartTrim
• Wide range • Industrial applications • Operation with/without cooling jacket
• SmartTrim • Submerged or dry installation
• Operation with/without cooling jacket Features and benefits • Different types of impellers
• Submerged or dry installation • High efficiency stainless steel propeller • Built-in motor protection
• Different types of impellers • Totally submerged installations • Various executions in stainless steel
• Built-in motor protection • Built-in motor protection • Liquids with a pH value between
• Flexibility of installation 2 and 14
Options
• Control and protection systems Options Options
• External cooling water • Control and protection systems • Control and protection systems
• External seal flush system • External cooling water
• External seal flush system

28
GRUNDFOS

SE DP, EF, SE1 and SEV

Heavy duty submersible pumps Drainage, effluent and sewage pumps

H [m] H [m]
40
30 20
20
10
10 6
4
6
4 2
3
2 1
5 10 15 20 30 40 60 100 1 2 3 5 7 10 30
Q [l/s] Q [l/s]

Technical data Technical data


Flow, Q: max. 88 l/s Flow, Q: max. 19,5 l/s (70 m3/h)
(315 m3/h) Head, H: max. 25 m
Head, H: max. 45 m Liquid temp.: 0°C to +40°C
Liquid temp.: 0°C to +40°C Discharge diameter: Rp 2 to DN 65
Discharge diameter: DN 65 to DN 150
Applications
Applications The pumps are suitable for:
The pumps are suitable for the following • Drainage
applications • Effluent
• Wastewater • Wastewater
• Process water • Process water
• Unscreened raw sewage • Domestic sewage
• Sludge-containing sewage
Features and benefits
Features and benefits • Cable plug connection
• Cable plug connection • Unique clamp connection
• Unique clamp assembly system • Single-channel and vortex impellers
• Single-channel and vortex impellers • Solids passage up to 65 mm
• Solids passage up to 100 mm • Unique cartridge shaft seal
• Low risk of clogging • Modular design
• Minimum downtime • Minimum downtime
• Low operating costs
• Liquidless motor cooling Options
• Unique cartridge shaft seal • Control and protection systems
• Modular design
• Motor operation control

Options
• Control and protection systems
• Motor operation control

29
30
Denmark France Japan Singapore
GRUNDFOS DK A/S Pompes GRUNDFOS Distribution S.A. GRUNDFOS Pumps K.K. GRUNDFOS (Singapore) Pte. Ltd.
Poul Due Jensens Vej 7A Parc d’Activités de Chesnes 1-2-3, Shin Miyakoda 24 Tuas West Road
DK-8850 Bjerringbro 57, rue de Malacombe Hamamatsu City Jurong Town
Tlf.: +45-87 50 50 50 F-38290 St. Quentin Fallavier (Lyon) Shizuoka pref. 431-21 Singapore 638381
Telefax: +45-87 50 51 51 Tél.: +33-4 74 82 15 15 Phone: +81-53-428 4760 Phone: +65-6865 1222
E-mail: info_GDK@grundfos.com Télécopie: +33-4 74 94 10 51 Telefax: +81-53-484 1014 Telefax: +65-6861 8402
www.grundfos.com/DK
Germany Korea Spain
Argentina GRUNDFOS GMBH GRUNDFOS Pumps Korea Ltd. Bombas GRUNDFOS España S.A.
Bombas GRUNDFOS de Argentina S.A. Schlüterstr. 33 6th Floor, Aju Building 679-5 Camino de la Fuentecilla, s/n
Ruta Panamericana km. 37.500 Lote 34A 40699 Erkrath Yeoksam-dong, Kangnam-ku, 135-916 E-28110 Algete (Madrid)
1619 - Garin Tel.: +49-(0) 211 929 69-0 Seoul Korea Tel.: +34-91-848 8800
Pcia. de Buenos Aires Telefax: +49-(0) 211 929 69-3799 Phone: +82-2-5317 600 Telefax: +34-91-628 0465
Phone: +54-3327 414 444 e-mail: infoservice@grundfos.de Telefax: +82-2-5633 725
Telefax: +54-3327 411 111 Service in Deutschland: Sweden
e-mail: kundendienst@grundfos.de Malaysia GRUNDFOS AB
Australia GRUNDFOS Pumps Sdn. Bhd. Box 63, Angeredsvinkeln 9
GRUNDFOS Pumps Pty. Ltd. Greece 7 Jalan Peguam U1/25 S-424 22 Angered
P.O. Box 2040 GRUNDFOS Hellas A.E.B.E. Glenmarie Industrial Park Tel.: +46-771-32 23 00
Regency Park 20th km. Athinon-Markopoulou Av. 40150 Shah Alam Telefax: +46-31 331 94 60
South Australia 5942 P.O. Box 71 Selangor
Phone: +61-8-8461-4611 GR-19002 Peania Phone: +60-3-5569 2922 Switzerland
Telefax: +61-8-8340 0155 Phone: +0030-210-66 83 400 Telefax: +60-3-5569 2866 GRUNDFOS Pumpen AG
Telefax: +0030-210-66 46 273 Bruggacherstrasse 10
Austria Mexico CH-8117 Fällanden/ZH
GRUNDFOS Pumpen Vertrieb Ges.m.b.H. Hong Kong Bombas GRUNDFOS de Mexico S.A. de C.V. Tel.: +41-1-806 8111
Grundfosstraße 2 GRUNDFOS Pumps (Hong Kong) Ltd. Boulevard TLC No. 15 Telefax: +41-1-806 8115
A-5082 Grödig/Salzburg Unit 1, Ground floor Parque Industrial Stiva Aeropuerto
Tel.: +43-6246-883-0 Siu Wai Industrial Centre Apodaca, N.L. 66600 Taiwan
Telefax: +43-6246-883-30 29-33 Wing Hong Street & Mexico GRUNDFOS Pumps (Taiwan) Ltd.
68 King Lam Street, Cheung Sha Wan Phone: +52-81-8144 4000 14, Min-Yu Road
Belgium Kowloon Telefax: +52-81-8144 4010 Tunglo Industrial Park
N.V. GRUNDFOS Bellux S.A. Phone: +852-27861706/27861741 Tunglo, Miao-Li County
Boomsesteenweg 81-83 Telefax: +852-27858664 Netherlands Taiwan, R.O.C.
B-2630 Aartselaar GRUNDFOS Nederland B.V. Phone: +886-37-98 05 57
Tél.: +32-3-870 7300 Hungary Postbus 104 Telefax: +886-37-98 05 70
Télécopie: +32-3-870 7301 GRUNDFOS Hungária Kft. NL-1380 AC Weesp
Park u. 8 Tel.: +31-294-492 211 Thailand
Brazil H-2045 Törökbalint, Telefax: +31-294-492244/492299 GRUNDFOS (Thailand) Ltd.
GRUNDFOS do Brasil Ltda. Phone: +36-34 520 100 947/168 Moo 12, Bangna-Trad Rd., K.M. 3,
Rua Tomazina 106 Telefax: +36-34 520 200 New Zealand Bangna, Phrakanong
CEP 83325 - 040 GRUNDFOS Pumps NZ Ltd. Bangkok 10260
Pinhais - PR India 17 Beatrice Tinsley Crescent Phone: +66-2-744 1785 ... 91
Phone: +55-41 668 3555 GRUNDFOS Pumps India Private Limited North Harbour Industrial Estate Telefax: +66-2-744 1775 ... 6
Telefax: +55-41 668 3554 Flat A, Ground Floor Albany, Auckland
61/62 Chamiers Aptmt Phone: +64-9-415 3240 Turkey
Canada Chamiers Road Telefax: +64-9-415 3250 GRUNDFOS POMPA SAN. ve TIC. LTD. STI
GRUNDFOS Canada Inc. Chennai 600 028 Bulgurlu Caddesi no. 32
2941 Brighton Road Phone: +91-44 432 3487 Norway TR-81190 Üsküdar Istanbul
Oakville, Ontario Telefax: +91-44 432 3489 GRUNDFOS Pumper A/S Phone: +90 - 216-4280 306
L6H 6C9 Strømsveien 344 Telefax: +90 - 216-3279 988
Phone: +1-905 829 9533 Indonesia Postboks 235, Leirdal
Telefax: +1-905 829 9512 PT GRUNDFOS Pompa N-1011 Oslo United Arab Emirates
Jl. Rawa Sumur III, Blok III / CC-1 Tlf.: +47-22 90 47 00 GRUNDFOS Gulf Distribution
China Kawasan Industri, Pulogadung Telefax: +47-22 32 21 50 P.O. Box 16768
GRUNDFOS Pumps (Shanghai) Co. Ltd. Jakarta 13930 Jebel Ali Free Zone
22 Floor, Xin Hua Lian Building Phone: +62-21-460 6909 Poland Dubai
755-775 Huai Hai Rd, (M) Telefax: +62-21-460 6910/460 6901 GRUNDFOS Pompy Sp. z o.o. Phone: +971-4- 8815 166
Shanghai 200020 ul. Klonowa 23 Telefax: +971-4-8815 136
PRC Ireland Baranowo k. Poznania
Phone: +86-512-67 61 11 80 GRUNDFOS (Ireland) Ltd. PL-62-081 Przezmierowo United Kingdom
Telefax: +86-512-67 61 81 67 Unit 34, Stillorgan Industrial Park Phone: +48-61-650 13 00 GRUNDFOS Pumps Ltd.
Blackrock Telefax: +48-61-650 13 50 Grovebury Road
Czech Republic County Dublin Leighton Buzzard/Beds. LU7 8TL
GRUNDFOS s.r.o. Phone: +353-1-2954926 Portugal Phone: +44-1525-850000
Cajkovského 21 Telefax: +353-1-2954739 Bombas GRUNDFOS Portugal, S.A. Telefax: +44-1525-850011
779 00 Olomouc Rua Calvet de Magalhães, 241
Phone: +420-585-716 111 Italy Apartado 1079 U.S.A.
Telefax: +420-585-438 906 GRUNDFOS Pompe Italia S.r.l. P-2770-153 Paço de Arcos GRUNDFOS Pumps Corporation
Via Gran Sasso 4 Tel.: +351-21-440 76 00 17100 West 118th Terrace
Finland I-20060 Truccazzano (Milano) Telefax: +351-21-440 76 90 Olathe, Kansas 66061
OY GRUNDFOS Pumput AB Tel.: +39-02-95838112 Phone: +1-913-227-3400
Mestarintie 11 Telefax: +39-02-95309290/95838461 Russia Telefax: +1-913-227-3500
Piispankylä OOO GRUNDFOS
FIN-01730 Vantaa (Helsinki) Shkolnaya 39
Phone: +358-9 878 9150 RUS-109544 Moscow
Telefax: +358-9 878 91550 Phone: +7-095 564 88 00, +7-095 737 3000
Telefax: +7-095 564 88 11, +7-095 737 7536
e-mail: grundfos.moscow@grundfos.com
V7055161 1204
Repl. 0704

You might also like