FMPC
Operator Quick Reference Guide 4 Scanner (SP) Start-up 6 Pre-operational Check in FRONTIER
Press the [Start] button to start up the scanner. [FRONTIER 350/370]
[FRONTIER 350/370] Select the "1 Pre-operational Check" on the Main
1 Start-up Menu screen and click [OK]. Then complete the
pre-operational check following the instructions
on the screens.
■ Start-up Procedures [FRONTIER 550/570]
Select.
1 Starting Up the Imaging Controller (1) Check if the built-in breaker is turned ON, then
turn ON the power switch.
Check if the peripherals are turned on, then start
up the Imaging Controller.
EZ1192
[FRONTIER 355/375/550/570]
Click.
LII987
C4C509
[FRONTIER 355/375/550/570]
2 Printer (LP) Start-up
IMPORTANT
When starting up the LP5500/5700, set the power Click the [Pre-operational Check] button on the
This Step is not required when "Time-startup" is switch to [STANDBY] during the post-operational Main Menu screen. Then complete the pre-
used. check. operational check following the instruction on the
[FRONTIER 350/370/355/375] screens.
ZII040 Click.
(1) Check if the built-in breaker is turned ON, then
turn ON the power switch.
Click.
EZ626
Power Switch
NMP010
2 Print Status Notice Screen
When "W-8102" Message Dialog Appears ! When "W-1621" Message Dialog Appears 1 The print size information registered in the "424 Print Size Setup" screen must match that of SP. When the
order is received from the SP while they are mismatched, the W-1623 (size not registered) message
The print-waiting orders that are listed up in the Mismatching of papers occurred in the same
appears and this order is not printed. When this happens, register the proper size, then resume printing on
"Next Print" list cannot be printed with the order, and no correct paper magazine was
the "Print Status Notice" screen.
currently installed paper(s). installed. This problem occurs especially when
the paper width of index print is different from that
2 To start up and shut down the FMPC system, make sure to use the following procedures.
of normal print.
Start-up: [Imaging Controller] -> [Printer<LP>(Timer-startup)] -> [FMPC] -> [Scanner<SP>]
Shut-down: [Scanner<SP>] -> [FMPC with Printer<LP>] -> [Imaging Controller]
3 Make sure to restart the FMPC so that the setting is sent to the Imaging Controller when adding or
updating the print size on the "424 Print Size Setup" screen in the "Setup and Maintenance" menu.
4 To shut down the FMPC and SP, make sure to turn off the SP then FMPC in this order. If they are turned
off in the reverse order, a communication error may occur during the completion process.
Wait for a moment with no operation, so this 5 When the FMPC is restarted (EX: after the print size is updated), the scanner<SP> must also be restarted.
message will disappear, then other print-waiting If the communication between FMPC and SP is not done well, the "E-1425" message appears on the
orders with the setting of paper that matches the scanner<SP>.
currently installed paper will be printed IMPORTANT
automatically, while skipping the orders with the If the [Abort] button is clicked during processing of the
mismatched paper setting. orders, transferring of orders is stopped, but they
remain in the system.
Click the [Resume] button on the printing status screen
To replace the magazine with the correct one,
to start printing from the first frame again.
click the [OK] button. Unless the orders with
Click the [OK] button, then to replace the magazine
mismatched paper are urgent ones, it is
with correct one, and then to start printing again.
recommended to print the possible orders first,
then the remaining orders after replacing the
magazine. [Order] : Outputs forcibly the current order.
[Image] : Outputs forcibly the current image.
[OK] : Replace the magazine with the correct
one, then click this button to start
When "W-1627" Message Dialog Appears printing.
Before clicking the [OK] button, make
This message appears when mismatching of
sure that the printer (LP) is initialized.
surface or emulsion type occurred between the
[Abort] : Returns to the printing screens where
upper and lower magazines. Click the [Abort]
you can start printing by clicking the
button, then select [Upper] or [Lower] magazine,
[Resume] button.
and then resume printing.
When the two paper widths are displayed (89mm,
127mm), the problem is the index paper
mismatch. Set one of the displayed widths, of
paper to solve the problem.
4 Shut-down
■ Shut-down procedures [FRONTIER 355/375/550/570] (2) On the "Next Time ON Date/Time check" (2) The Confirmation dialog appears. Click the [OK]
1 (1) Click the [Post-operational Check] button. screen, click [Shut Down]. button.
Post-operational Checks and Shut-down
in FRONTIER Then perform the post-operational check
following the instructions on the screens.
[FRONTIER 350/370]
Click
(1) Select the "Post-operational Checks" and
click [OK]. Then perform the post-operational
check following the instructions on the Click.
screens.
To shut down the computer, click the [Exit]
Select.
button while pressing the [Shift] button.
Click.
Click.