INTRODUCTION
This message and actions manual lists up the messages which may occur (be displayed) during
operating or maintaining the FE software.
This manual should be kept in a fixed place near the machine so that it can be referred to any time
a point needs to be clarified.
The following symbols indicating the model and software names are used in this manual.
Symbol Software/Model
3
1 Explanatory Note
The messages are identified by the following blocks of numbers that are assigned to the following locations,
operations and applications.
NOTE:
If the errors concerning the SP1500/2000/LP1500/2000SC or SLP-800SC/1000SE (“2XXX” messages) occur
when using the traditional system including the models above, refer to the “Message and Actions” chapter of
each instruction or service manual.
X-4329, W-4332, W-4333, W-4339, X-4340, X-4368, I-4378, W-4883, I-4884, W-4941, W-4942, W-4943,
and from W-7233 to I-7266
[Message Symbol]
4
[Message Icon]
Errors with symbol “E”, “W” or “X” (that can be recovered after
proper measurement is taken.)
5
2 Message and Actions
No Message Actions
X-P7-0003 Software error occurred. If problems persist after restart, consult your
technical representative.
If problems persist after restart, consult your
technical representative.
W-P7-1001 Converting of image failed. Delete the order.
6
No Message Actions
E-P7-1004 Connection setting to the conventional system is Try the connection setting again.
abnormal.
7
No Message Actions
W-P1-1009 No image file was found in the media. 1. Please register it again after having canceled
the order.
Please register itself again after having canceled an 2. Press the “i” icon at lower left, then press the
order. [Stop the order] button in “System Information
and Operations Setup”.
Order Stop: Press [i] icon at lower left, then press
[Stop the order] in “System Information and
Operations Setup”
X-Q1-1009 Software error occurred. Try it again. If problems persist, consult your
technical representative.
Billing information cannot be saved.
8
No Message Actions
W-P1-1014 Order information cannot be used. Cancel order 1. Press the [No] button stop the ordering
information, then continue operation? process, then register it again.
2. Press the “i” icon at lower left, then press the
If [No] was selected, stop the ordering process, then [Stop the order] button in “System Information
register it again. and Operations Setup”.
9
No Message Actions
E-Q1-1018 Software error occurred. Billing information setting is abnormal. Check
whether or not the product information is set
Product was not found. correctly on PLMaker.
Enter it again.
10
No Message Actions
W-P1-1022 A large print size is selected while the 600dpi is to Select “300dpi”, or check the print size.
be set.
Register it again.
W-Q1-1024 Printing error occurred. Check the printer setting, then print it again.
11
No Message Actions
I-P1-1027 Image data full. Please wait a moment. 1. Press the [Cancel] button to stop the ordering
process, then register it again.
If [Cancel] was selected, stop the ordering process, 2. Press the “i” icon at lower left, then press the
then register it again. [Stop the order] button in “System Information
and Operations Setup”.
Order Stop: Press [i] icon at lower left, then press
[Stop the order] in “System Information and
Operations Setup”
E-Q1-1027 Output destination is not selected yet, so the billing 1. Select the printer on the “Billing Environment
was not outputted. Setup” screen.
2. Perform the billing again on the “Order
Select the [Printer] on the “Billing Environment Manager” screen.
Setup” screen.
12
No Message Actions
W-Q1-1037 Discount value is larger than subtotal value. Check the discount setting
13
No Message Actions
W-1401 Scanning lamp not stabilized. After stabilized, 1. Press the [End] button to end pre-scanning.
perform pre-scanning. 2. Press the [Run] button to skip the scanning
lamp stabilization and perform pre-scanning
Press [End] to end pre-scanning. immediately.
Please wait.
14
No Message Actions
W-1417 An error occurred during creating of image. If problems persist after restart, consult your
technical representative.
Do the pre-scan again.
W-1418 ##### not installed or paper end processing in Install the magazine, or replace it.
progress.
15
No Message Actions
W-1428 A communication error occurred between the main If problems persist after restart, consult your
control section and #####. technical representative.
16
No Message Actions
X-1440 Software error. Restart the system. If problem persists, consult
your technical representative.
Restart the system.
X-1441 Software error. Restart the system. If problem persists, consult
your technical representative.
Restart the system.
X-1442 Software error. Restart the system. If problem persists, consult
your technical representative.
Restart the system.
E-1443 Communication error occurred between main Restart the system. If problems persist, consult
controller and image processor. your technical representative.
17
No Message Actions
I-1455 Magnetic data registered on film failure. Press the [OK] button to continue processing.
18
No Message Actions
W-1478 Series Scene magnetic information failure. Continue processing.
Continue process.
W-1479 Template image size does not match print size. Confirm print size and template size.
19
No Message Actions
I-1490 Prepare for the diffusion plate cleaning. 1. Press the [Clean] button to move the slider to
the cleaning position.
Press [Clean] to move the slider to the cleaning 2. Press the [Skip] button to perform the scanner
position. correction.
20
No Message Actions
W-1511 Next timer-ON time exceeds the limit. Verify present date and time.
21
No Message Actions
E-1536 Error occurred during the order completion. See “S1 Instruction Manual [Operating
Instructions]”.)
Incorrect order status.
22
No Message Actions
W-1548 Printer processor not in standby. See “S1 Instruction Manual [Operating
Instructions]”.)
Check the network connections, and then press the
[Retry] button.
Enter characters?
I-1558 Printing the image being composed. Wait until it ends.
W-1560 Creating order failed Check for problems and then try again.
W-1561 Sending order failed Check for problems and then try again.
23
No Message Actions
W-1562 Adding order failed. Check for problems and then try again.
W-1563 Deleting order failed. Check for problems and then try again.
I-1564 Printing external file. Wait until printing is completed.
Wait!
W-1565 Registering device with FDi failed. Press the [Retry] button to retry or the [Cancel]
button to cancel.
Press [Retry] to retry or [Cancel] to cancel.
W-1566 Printing the image file. Couldn't perform the pre- Wait a while and then reload the film.
scan.
Eject film.
Wait!
E-1571 Message definition file not found or defective. If problems persist after restart, consult your
technical representative.
Check message definition file.
W-1572 Incorrect font size value. Specify 8 to 72 points as font size.
24
No Message Actions
W-1584 Editing quality information failed. Restart the system. If problem persists, consult
your technical representative.
W-1585 Reading of received data failed. Check to see if received data is correct and try
again.
Sending of the MI NETWORK mail canceled.
W-1586 Couldn't start scan, because the service to be See “S1 Instruction Manual [Operating
exported is not started. Instructions]”.)
Eject film.
Please wait.
I-1588 Saving print mag. fine adjust data. Wait until the message disappears.
Please wait.
W-1589 Carrier/mask and composite type mismatch, couldn't Select a correct carrier or mask that matches the
start scan. template.
Please wait.
I-1594 Reading service name list. See “S1 Instruction Manual [Operating
Instructions]”.)
Please wait.
I-1595 Start the connection with Imaging Controller, and See “S1 Instruction Manual [Operating
update the data. Instructions]”.)
Eject film.
25
No Message Actions
I-1598 Processing Red-eye/Soft/Cross #####. Wait until the message disappears.
E-1599 An error occurred. End the Red-eye/Soft/Cross mode. Install the
carrier or mask and then try again.
Couldn't continue the “Red-eye/Soft/Cross”.
Eject film.
E-1706 This function is not supported. -
E-1710 Templates are not available for the bordered print. Select a borderless print size.
26
No Message Actions
W-1726 Because this film has the FTPM or Series Scene Stop the current process, then print the images
data, the [All] cannot be used. one by one.
Please wait.
W-1738 Couldn't perform pre-scan. Use the 135 lane of the auto film carrier.
27
No Message Actions
I-1742 Cannot find the selected template. Register the corresponding template.
I-1743 The print size for the selected template not Register the print size for the selected template.
registered.
I-1744 The year in the calendar template is out of range. Input a year within the specified range.
Eject film.
W-1756 Printing... Wait until the processing is completed.
Please wait.
W-1762 Print Mode Select cannot be done while the scanned Complete a mounted print, or click the [Print] or
image is mounted. the [Cancel] button in the “Image Preview”
screen, and then select it again.
Complete a mounted print, or press the [Print] or the
[Stop] button in the “Image Preview” screen, and
then try it.
28
No Message Actions
W-1763 The printing operation cannot be canceled while the Complete a mounted print, or click the [Print] or
image is mounted. the [Cancel] button in the “Image Preview”
screen, and then select it again.
Complete a mounted print, or press the [Print] or the
[Stop] button in the “Image Preview” screen, and
then try it.
W-1764 Cannot replace the magazine while the Printing Quit the printing status notice screen and then
Status Notice screen is displayed. replace the magazine.
29
No Message Actions
E-1780 Could not detect the frame No. Specify the frame correctly or insert the correct
film piece.
Could not print with this film strip.
Eject film
W-1787 The magazine is not installed properly. Install the paper magazine correctly.
Install it properly.
I-1788 The frame information will be discarded. OK? -
E-1789 Couldn't open the function key setting file. If problems persist after restart, consult your
technical representative.
E-1790 The parameter is not correctly written in the function If problems persist after restart, consult your
key setting file. technical representative.
W-1791 Cannot send the status information to the Imaging Check the cable connection. If the problem
Controller. persists, consult your technical representative.
30
No Message Actions
W-1795 The carrier that is appropriate to the reorder printing Install the proper carrier.
is not installed.
Select it.
I-1805 Because carrier or mask was changed, settings
-
done in this dialog box will be cancelled.
W-1806 Last image Press the [OK] button to complete monitoring.
Replace mask.
E-P0-1808 Multiple output devices found in the same work Check the installation state of all devices.
group.
31
No Message Actions
I-P0-1809 You cannot return to the main menu screen during After processing is completed, return to the main
processing of the image. menu screen.
32
No Message Actions
W-P0-1824 Print size may be mismatched to the one selected in Check if the correct size is selected.
scanner(SP).
Set it.
W-P0-1826 Incorrect shop logo in Index for Media for selected Change the current logo to the correct one in the
digitize service. “Index for Media Setting” dialog.
Please wait.
I-1908 Available frame not detected. Eject film. Check the film.
33
No Message Actions
I-1909 Light source not stabilized. After the stabilization, 1. Press the [End] button to exit the image
positioning of image will be displayed. position adjustment.
2. Press the [Run] button to start the image
Press the [End] to exit the image position position adjustment ignoring the stabilization
adjustment. of the light source temperature.
Please wait.
W-1917 Paper width and print size of negative sheet index Replace the paper magazine, or change the
mismatched. index format.
If the [Output] button is clicked, an incorrect
Press [OK] and replace with the magazine of ##### index print will be output.
mm.
34
No Message Actions
W-1922 When the format type is #####, the current paper Replace the paper magazine, or change the
width and the print size selected as index format is index format.
mismatched. If the [Output] button is clicked, an incorrect
index print will be output.
Press the [OK] button and replace the paper
magazine, or change the index format.
35
No Message Actions
W-1931 Selected print size or surface and that in selected 1. Press the [OK] button, and then replace the
magazine mismatched. magazine.
2. To output forcibly, press the [Output] button.
Press [OK], then replace magazine.
36
No Message Actions
W-1943 Surface in magazine and that for negative sheet 1. Press the [OK] button, and then replace the
index mismatched. magazine.
2. If the [Output] button is pressed, negative
Press [OK] then replace magazine. sheet index prints with the correct surface will
not be outputted.
If [Output] is pressed, negative sheet index with
correct surface will not be outputted.
W-1944 Paper width or surface in selected magazine and 1. Press the [OK] button, then replace for
that for negative sheet index mismatched. magazine with correct size.
2. If the [Output] button is pressed, negative
Press [OK], then replace for magazine with ##### sheet index prints will not be outputted
mm. correctly.
37
No Message Actions
W-1950 Paper width or surface in selected magazine and 1. Press the [OK] button, and then replace the
that selected for Multi-Image print mismatched. magazine, or change print size.
2. If the [Output] button is pressed, Multi-Image
Press [OK] then replace magazine or change print prints will not be outputted correctly.
size.
38
No Message Actions
W-1957 Memory is full, so pre-scan cannot be performed. Wait until it ends.
Wait a moment.
X-1995 Parameter to display error (#####) incorrect. Input the correct parameter.
X-1996 Sub-system ID is incorrect (#####). Restart the system. If problem persists, consult
your technical representative.
Error source terminal ID: #####
X-1997 Incorrect Error No. Restart the system. If problem persists, consult
your technical representative.
Sub-system: #####
39
No Message Actions
W-P6-2116 CD-R is not inserted, or the file is damaged in all Check if the CD-R is correct one, if it is incorrect.
sessions.
Ok to continue work?
W-P6-2134 The value entered does not match the CD-ID for the Enter the CD-ID for the CD-R to do additional
CD-R to do additional write. write.
Enter path.
W-P6-2142 The following character can not use as a folder Change the folder name.
name.(/;*?<>)
40
No Message Actions
W-P6-2144 Creating the directory has failed. Check if the drive is writable and if the space is
sufficient.
Check if the drive is writable and if the space is
sufficient.
W-P6-2145 Entered path name exceeds 200byte. Enter a path within 200byte
Prepare CD-R.
W-P6-2152 Inserted CD-R is not for FUJICOLOR CD. Use a FUJICOLOR CD-R.
41
No Message Actions
W-P6-2169 Failed to write. Restart the system, and then try it again.
W-P6-2170 Failed to write to Media. Media may not be inserted. Prepare Media.
Prepare Media.
W-P6-2171 If controls returns to the WFA screen, all operations Click the [No] button, and then try it again.
done in the Revisions screen will be cancelled.
Continue importing?
E-P6-2201 Setting for CD writing software may be incorrect. Check the setting for CD writing software.
Check settings.
W-P6-2210 View and order process is currently performed. After this process is completed, try it again.
42
No Message Actions
W-Q0-4001 Selected job is not found. Check the job ID, then select it again.
43
No Message Actions
X-Q0-4018 Software error occurred. Restart the system.
If problems persist after restart, consult your
Restart all devices. technical representative.
44
No Message Actions
W-Q0-4028 This job was deleted or changed. Press the [Refresh] button to refresh the
displaying list, make necessary adjustments, and
Couldn't execute job. then try again.
45
No Message Actions
W-Q0-4038 Processing job. Wait until it is completed, and then retry it.
46
No Message Actions
X-Q0-5003 Software error occurred. Restart the system.
If problems persist, consult your technical
Cannot get the detailed order information. representative.
47
No Message Actions
W-Q0-5013 Cannot reissue the order because the image data Select another order, and then press the
exceeds the limitation period. [Reorder] button, or enter the same order again.
48
No Message Actions
W-Q0-5026 This Order was deleted or changed. Press the [Refresh] button to refresh the
displaying list.
Couldn't set express to order.
49
No Message Actions
I-Q0-5051 There is a product whose quantity is not decided. 1. To fix quantity of all completed orders, press
the [All] button. To fix them while ignoring the
To fix quantity of all completed orders, press [All]. To uncompleted order, press the [OK] button.
fix them while ignoring the uncompleted order, press 2. If the [OK] button is pressed, note that you
[OK]. cannot bill the product when its quantity is not
fixed.
If [OK] is pressed, note that you cannot bill the
product when its quantity is not fixed.
W-Q0-5052 Cannot continue operation because any product is Cancel the job in “Workflow Advisor” screen, or
being processed. retry it after the process is completed
50
No Message Actions
X-Q0-5060 Software error occurred. Correct the quantity. If problems persist, consult
your technical representative.
Quantity of any print product exceeds the limitation
“9980010”, so it will be changed to “9980010”.
I-Q0-5061 Limiting quantity for this product is “799200”. Enter the value within “799200”
51
No Message Actions
I-5103 Film reversed. Reload the film.
(Retry over)
(Retry over)
52
No Message Actions
W-IL-5309 The image file is not supported type. Cancel the order temporarily, and then check it.
53
No Message Actions
W-Q0-6006 Folder setting is incorrect. Select the folder again.
Select folder.
I-Q0-6009 Read the product price. Do not start the billing process until reading of
the product price information is completed.
Do not start billing process until reading of product
price information is completed.
I-Q0-6010 Initial the system configuration information. Restart the system after initializing it.
54
No Message Actions
W-Q0-6024 Print size name to be deleted is not selected. Select the order print size name.
55
No Message Actions
W-Q0-6036 Time for level 3 is incorrect. Set a time value between 0 and 60 min.
56
No Message Actions
E-Q0-6050 Gaining of service time information failed. Restart the system.
If this error persists, reinstall the software.
Restart the system.
57
No Message Actions
W-Q0-6069 Gaining of printer information failed. Restart the system.
If this error persists, reinstall the software.
Restart the system.
58
FAX : 81-3-5484-0454
Name :
E-mail Address :
Question 2 • Have you found any technical errors, errors in spelling, or missing words in this manual?
Yes No
• If you have ticked (Yes), please let us know what these errors and missing words are.
Question 3 • How would you rate the writing (language, choice of words/phrases, etc.) and the illustrations/
diagrams, etc.?
(1) Clear and easy to follow (2) Should be simplified
(3) Difficult to follow
(1)’ [Illustrations, etc.] Of adequate size
(2)’ [Illustrations, etc.] Too small
(3)’ [Illustrations, etc.] Difficult to follow
• If you have ticked (2), (3) or (3)’, please give us your reasons.
Additional
Comments/
Requests
concerning
This Manual
<FUJIFILM ABROAD>
in North America FUJI PHOTO FILM U.S.A., INC.
200 Summit Lake Drive, Valhalla, New York 10595-1356, U.S.A.
FUJI PHOTO FILM CANADA INC.
600 Suffolk Court, Mississauga, Ontario, L5R 4G4, Canada
FUJI PHOTO FILM HAWAII, INC.
94-468 Akoki Street, Waipahu, Hawaii 96797, U.S.A.
in Europe FUJI PHOTO FILM (EUROPE) G.m.b.H.
Heesenstrasse 31, 40549 Dusseldorf, Germany
FUJI PHOTO FILM (U.K.) LTD.
Fuji Film House, 125 Finchley Road, Swiss Cottage, London NW3 6HY, U.K.
FUJIFILM ESPAÑA, S.A.
Aragon, 180, 08011-Barcelona, Spain
FUJIFILM FRANCE SAS
Parc d' Activites du Pas-du-Lac-2, Avenue Franklin, 78186 St. Quentin en Yvelines Cedex, France
in Central America FUJI PHOTO FILM CO., LTD., MEXICO OFFICE
Av. Ejercito Nacional 351, 5˚ piso, Col. Granada, 11520 Mexico D.F., Mexico
in South America FUJI PHOTO FILM DO BRASIL LTDA.
Avenida Vereador Jose Diniz, No. 3400, Campo Belo, São Paulo CEP 04604-901,
Cx. Postal 3656, Brazil
in Asia FUJI PHOTO FILM CO., LTD., HONG KONG OFFICE
Room 2208, Tower 6, The Gateway Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong
FUJIFILM REGIONAL SERVICES (SINGAPORE) PTE. LTD.
10 New Industrial Road, Fujifilm Building, Singapore 536201
FUJI PHOTO FILM (THAILAND) LTD.
S.P. Building, 8th Floor, 388 Phaholyothin Road, Bangkok 10400, Thailand
FUJI PHOTO FILM (MALAYSIA) SDN. BHD.
Letter Box 3, 3rd Floor Office Block 1, Crystal Plaza Lot 4, Jalan 51A/223
46100 Petaling Jaya Selangor Darul Ehsan Malaysia
FUJI PHOTO FILM CO., LTD., TAIPEI OFFICE
Rm. 601, Hung Chong Bldg., No. 38, Sec. 6, Min Chuan E. Road, Taipei 11453, Taiwan
FUJI PHOTO FILM CO., LTD., SEOUL OFFICE
505-19, Kasan-Dong, Kumchon-Gu, Seoul, Korea 152-020
FUJI PHOTO FILM CO., LTD., BEIJING REPRESENTATIVE OFFICE
Beijing Fortune Bldg. No. 817, 5, Dong Sanhuan Bei-lu, Chaoyang District, Beijing, China 100004
FUJI PHOTO FILM CO., LTD., HO CHI MINH OFFICE
7th Floor Sun Wah Tower, 115 Nguyen Hue Street, Dist. 01, Ho Chi Minh City, Vietnam
FUJI PHOTO FILM CO., LTD., NEW DELHI OFFICE
Le Meridien Commercial Tower 8F, Janpath, New Delhi 110001, India
FUJI PHOTO FILM CO., LTD., MANILA OFFICE
c/o YKL Development & Trading Corporation, 24 Sto. Domingo St., Quezon City, Metro Manila, Philippines
in Oceania FUJIFILM AUSTRALIA PTY LTD
c/o Hanimex Pty. Limited, 114 Old Pittwater Road, Brookvale, N.S.W. 2100, Australia
FUJIFILM NZ LIMITED
Cnr Willam Pickering Drive and Bush Road, ALBANY, New Zealand
in the Middle East FUJI PHOTO FILM CO., LTD., DUBAI OFFICE
No. 14, L.O.B. No. 4, P.O.Box 17212, Jebel Ali, Dubai, U.A.E.
in South Africa Fuji Photo Film Co., Ltd., Johannesburg Office
9th Floor, Sandton City Office Towers, Cnr Rivonia Road & 5th Street, Sandton 2196, South Africa