BILL OF QUANTITY

ADDITIONAL LAMP FOR SOME AREA WITHIN PAITON UNIT 3

No. Material Qty Unit Remarks


A. West side of clorination building
1 150 Watt LED lamp Flood Light Type (Water Proof) 3 Set Philips saving energy (LED) lamp type
Support shall be form Galvanized Steel Type or OEM lamp
2 Lamp support to match with the exisitng structure 3 Set
support

3 Conduit Pipe with 1 inch diameter including all the 1 Lot estimated total length is about 40m
required accessories

Bidder shall check to site in order to determined the required


Temporary access plat form suitable for installation
4 works 1 Lot quantity of scafolding requirement (owner rough calculation
there is 3 point access with max7m height)

B. Mobile Trash Rack System


1 100 Watt LED lamp Flood Light Type (Water Proof) 4 Set Philips saving energy (LED) lamp type
Support shall be form Galvanized Steel Type or OEM lamp
2 Lamp support to match with the exisitng structure 4 Set
support
Lamp post suitable for mobile trash rack hand rail 1 m of height post shall be form Galvanized Steel pipe Type or
3 2 Set
installation OEM lamp post
Conduit Pipe with 1/2 inch diameter including all the
3 required accessories 1 Lot estimated total length is about 18m

Temporary access plat form suitable for installation Bidder shall check to site in order to determined the required
4 works 1 Lot quantity of scafolding or 1 point platform requirement

C. Right side of main gate


1 set of traffic warning lamp that consist of 2 (two) dim
1 lamps 1 Set Philips saving energy (LED) lamp type
4 m height or follow manufacturer standars or industrial
2 Galvanized self stand support suitable for the LED lamp 1 Set
common practice
Conduit Pipe with 1 inch diameter including all the
3 1 Lot estimated total length is about 3m
required accessories

D. Some area on WTP areas

re-route of their power source of 6 lamps i.e. 3 high bay


1 sodium lamps and 3 other free standing lamps located at 3 Set Philips saving energy (LED) lamp type
water treatment plant SWRO module area

Bidder shall check to site in order to determined the required


Temporary access plat form suitable for installation
2 1 Lot quantity of scafolding requirement (owner rough calculation
works
there is 3 point access with max 5m height)

E. Battery Room

2 x 36 W fluorescent LED lamps with reflector type with


1 hazardous area classification as class 1 div. 1 group B 12 Set Philips saving energy (LED) lamp type

2 x 36 W fluorescent LED lamps reflector with battery 90


2 min type with hazardous area classification as class 1 div. 3 Lot Philips saving energy (LED) lamp type
1 group B

3 Exit sign single face LED tipe with battery with hazardous 2 Set Philips saving energy (LED) lamp type
area classification as class 1 div. 1 group B

Socket outlet, exposed type AC 240V 2P+E 16 A with


4 4 Set
hazardous area classification as class 1 div. 1 group B

5 3-Way switch box with hazardous area classification as 2 Set


class 1 div. 1 group B