You are on page 1of 1

GROUP No.

: DOUBLING ELECTRIFICATION
SUBMITTED APPROVED C.S.D AS ERECTED SECTION: ARAVALLI TO ATTILI
SCL-CRC 21B (JV) PAGE
LAYOUT NO: SCL-CRC 21B (JV)/LOP/122-126
9A
Rail Vikas Nigam Limited. CHAINAGE: 122/294.90
(A Govt. Of India Enterprise)
FOR SCL-CRC 21B (JV) RE/E/PMC/TNKU GGM/E/RVNL/SC GGM/E/RVNL/SC WIND PRESSURE: 178 kgf/m² GRADE OF CONCRETE:M-15
LOCATION NO. 122/13
122 MAST TYPE B-150
MAST LENGTH 9.50m
13 REV. DEF. IN mm +30
NATURE OF SOIL BUILT UP SOIL
SOIL PRESSURE 8000 kg/m²

MAST
FOUNDATION REF. 147/MG-06
ANCHOR BLOCK
SUPERMAST ----

NDD
RC/FEEDER HT. (M) ----
CATENARY HT. (M) ----
CONTACT HT. (M) ----
SPAN (M) 40.50/45.00
VERSINES / RADIUS TANGENT
SUPER ELEVATION
STYLE
DRG. No.

7.65
DN.MAIN UP MAIN

BRACKET ASSLY.
CANTILEVER ASSY. 9200
EXG. DN. LINE
PRO.UP.LINE STAY ARM 2400

9.50
7.00 0.300 STANDARD BRACKET 2040
3.60 LARGE BRACKET 2080
REGISTERD ARM 2420
RAISED REG. ARM 2430
STEADY ARM 2390
JUMPER 1010
PRO. RL INSULATOR ---
0.50 DROPPER 9207
GL
GL STYLE
CL CL DRG. No. DN.MAIN UP MAIN
1.50 1.35
GUY ROD ETI/OHE/P/5000

MISC ASSLY.
TERMINATION 1005
ANCHOR 1006
FEEDER/RC-SUSPN. 1008
NOTE : GUIDE TUBE MTG. ETI/OHE/G/01505
SPS FOR RC/FEEDER SUSPN. ETI/C/P/
* TYPE OF SOIL AND PRESSURE TO BE ASCERTAINED AT SITE AND FOR ANY CHANGE IN TYPE OF FDN,
APPROVAL OF GGM/E TO BE OBTAINED. SPS FOR BRACKT MTG. 1001
* STEP DISTANCE SHOULD BE MEASURED FROM H.R.L NUMBER PLATE MTG. ETI/OHE/G/01701
* TC & RL SHOULD BE ENSURED BEFORE CASTING FOUNDATIONS ON PRO TRACK SIDE
STRUCTURE BOND ETI/OHE/P/7000
ITEM STAY INSULATOR BKT. INSULATOR 9-T INSULATOR SS WIRE ROPE CONTACT WIRE CATENARY WIRE
MAKE/YEAR