You are on page 1of 2

LEGEND: 2-Ø12-200

C ---- CENTER LINE


THK ---- THICK BAR SPACING C/C
FGL ---- FINISH GROUND LEVEL DIA OF BAR
0.5 TCT AZ-150 NGL ---- NATURAL GROUND LEVEL
CONC.-- CONCRETE LEVEL
HYSD BAR

SHEET 1235X450 MM 0.5 TCT AZ-150 IL.-------- INVERT LEVEL


NUMBER OF
BARS/LINKS
1235 4 SHEET 1235X450 MM
LVL.----- LEVEL
UNO----- UNLESS NOTED OTHERWISE

769.5 6-14Ø HOLES

100

100
FOR M12 BOLT 450 ISA 50X50X5
1

GENERAL NOTES:
300 1. ALL DIMENSION ARE IN MM AND LEVEL ARE IN
METERS.
2. DO NOT SCALE THE DRAWING ONLY WRITTEN

1323
DIMENSION TO BE FOLLOWED.

L50X50X5

L50X50X5
SCB PANEL
L50x50x5
3. GRADE OF CONCRETE SHALL BE M25 WITH 20

700
MM NOMINAL SIZE OF AGGREGATES AS PER IS
456.
723

723
4. CONTRACTOR SHALL CHECK ALL DIMENSIONS
& LEVELS BEFORE EXECUTION OF WORK.
SCB PANEL 5. DISCREPANCY IN DRAWING, IF ANY, SHALL BE
BROUGHT TO THE NOTICE OF THE SITE
ENGINEER, PRIOR TO CONSTRUCTION.
6. DIMENSIONS & LEVELS ARE TO UNFINISHED
L40X40X3 SURFACES EXCLUDING FINISHES, COATING,
200 100 200

200 100 200


LININGS ETC.
7. GALVANIZATION LAYER OF STRUCTURAL
CABLE SUPPORT MEMBERS SHALL BE WILL BE 80 MICRON .
8. MAINTAIN CLEAR COVER OF 50 MM FROM THE
L40X40X3 BOTTOM OF PILE.
500

300

9. STRUCTURAL STEEL SHALL BE FY 250.


10. MS BOLTS AND NUTS SHALL BE OF 8.8 GRADE,
CONFORMING TO METRIC SCREW THREAD.
N.G.L.
600

600
50

1 ELEVATION VIEW 1-1 R2 21.03.24 FOR APPROVAL


R1 28.02.24 FOR APPROVAL
R0 22.02.24 FOR APPROVAL
REV. DATE REVISION HISTORY
PROJECT TITLE :
1235 150
150 50MW(AC) SOLAR PV PLANT, KANAKGIRI, KARNATAKA, INDIA
824.5 935 4 OWNER AMP ENERGY C&I TWENTY FOUR PVT.LTD.
50

769.5 50X50X5 CLIENT :

AMP ENERGY INDIA PVT. LTD.


175 175

EPC CONTRACTOR:

450
SCB PANEL RAYS POWER INFRA PVT. LTD., D-43,
JANPATH, SHYAM NAGAR, JAIPUR - 302019
50

Ø300X700 DRAWING TITLE :


PLAN SCB STRUCTURE AND FOUNDATION
M25 Grade
M 6 SELF TAPPING 880 DRAWING NO. : RPIPL-KNK-OA-AMP-CE-DWG-SCB-001
SCREWS SITE CO-ORDINATE.:

SHEET NO. SCALE N.T.S.


DRAWN DB PAPER SIZE A0
CHECKED AS REV NO. R2
APPROVED NSG DATE 21.03.24
LEGEND: 2-Ø12-200
C ---- CENTER LINE
THK ---- THICK BAR SPACING C/C
FGL ---- FINISH GROUND LEVEL DIA OF BAR
NGL ---- NATURAL GROUND LEVEL HYSD BAR
CONC.-- CONCRETE LEVEL
NUMBER OF
IL.-------- INVERT LEVEL
BARS/LINKS
LVL.----- LEVEL
UNO----- UNLESS NOTED OTHERWISE

GENERAL NOTES:
1. ALL DIMENSION ARE IN MM AND LEVEL ARE IN
METERS.
1873 2. DO NOT SCALE THE DRAWING ONLY WRITTEN
DIMENSION TO BE FOLLOWED.
3. GRADE OF CONCRETE SHALL BE M25 WITH 20

850 200 723 100 MM NOMINAL SIZE OF AGGREGATES AS PER IS


456.
4. CONTRACTOR SHALL CHECK ALL DIMENSIONS
L50X50X5 & LEVELS BEFORE EXECUTION OF WORK.
5. DISCREPANCY IN DRAWING, IF ANY, SHALL BE
3-14Ø HOLES BROUGHT TO THE NOTICE OF THE SITE
ENGINEER, PRIOR TO CONSTRUCTION.
FOR M12 BOLT
6. DIMENSIONS & LEVELS ARE TO UNFINISHED
SURFACES EXCLUDING FINISHES, COATING,
LININGS ETC.
MAIN LEGS 7. GALVANIZATION LAYER OF STRUCTURAL
MEMBERS SHALL BE WILL BE 80 MICRON .
ISA 50X50X5
8. MAINTAIN CLEAR COVER OF 50 MM FROM THE
(2 NOS.) BOTTOM OF PILE.
9. STRUCTURAL STEEL SHALL BE FY 250.
10. MS BOLTS AND NUTS SHALL BE OF 8.8 GRADE,
CONFORMING TO METRIC SCREW THREAD.

814.5
22.5
22.5
769.5

2-14Ø HOLES
CABLE SUPPORT
FOR M12 BOLT
ISA 40X40X3
(1 NOS.)

450 R2 21.03.24 FOR APPROVAL


R1 28.02.24 FOR APPROVAL
R0 22.02.24 FOR APPROVAL
REV. DATE REVISION HISTORY
M6 SELF TAPPING PROJECT TITLE :
CANOPY SUPPORT
SCREWS 50MW(AC) SOLAR PV PLANT, KANAKGIRI, KARNATAKA, INDIA
ISA 50X50X5
(2 NOS.) OWNER AMP ENERGY C&I TWENTY FOUR PVT.LTD.

CLIENT :

AMP ENERGY INDIA PVT. LTD.

EPC CONTRACTOR:
RAYS POWER INFRA PVT. LTD., D-43,
JANPATH, SHYAM NAGAR, JAIPUR - 302019

DRAWING TITLE :
FABRICATION DRAWING SCB STRUCTURE AND FOUNDATION

DRAWING NO. : RPIPL-KNK-OA-AMP-CE-DWG-SCB-001


SITE CO-ORDINATE.:

SHEET NO. SCALE N.T.S.


DRAWN DB PAPER SIZE A0
CHECKED AS REV NO. R2
APPROVED NSG DATE 21.03.24