NOTES:

1. ALL DIMENSIONS ARE IN MILIMETRES & LEVELS IN METRES.

2. THIS DWG SHALL NOT BE SCALED, ONLY WRITTEN DIMENSIONS

TO BE FOLLOWED.

3. USE CONCRETE GRADE M25 (DESIGN MIX) UNLESS SPECIFIED


3-T12 3-T12 2-T12 3-T16 4. MINIMUM CLEAR COVER TO REINFORCEMENT
2-T12
500 500 FOOTINGS: 50 (TO OUTERMOST BARS), COLUMNS: 40 (TO MAIN BARS)

Ld Ld BEAMS: 25 (TO STIRRUPS), SLABS: 25 (TO OUTERMOST BARS)

3-T12 5. LAP LENGTH SHALL BE AS FOLLOWS


3-T12 2L-T8
1743 1743 @150 C/C
FOR COLUMNS 40d, OTHERS 50d (d IS BAR DIA)
2L-T8 2L-T8 2L-T8 2L-T8 3-T12 2-T12
C5 @200 C/C @175 C/C @200 C/C @175 C/C C8 C9 C10 6. THIS DWG SHALL BE READ IN CONJUCTION WITH RELEVANT
C7 B3:230x500 2L-T8
B1:230x610 B2:230x610 ARCHITECTURAL DWG.
@150 C/C
7. ANY DISCREPANCY SHALL BE DISCUSSED WITH THE
3-T12
B4:230x500 2L-T8 CONSULTANT BEFORE THE WORK IS EXECUTED.
@200 C/C
C11 8. STEEL GRADE TO BE Fe500
730 B5:230x610
3-T12 2-T12 2-T12 9. COLUMN TERMINATES AT THIS LEVEL.

500 500 2-T12 10. REFER GENERAL ALIGNMENT DETAILS SKA/51/01


Ld 3-T12
Ld
3-T12
970 970
2L-T8 2L-T8 2L-T8 2L-T8
@150 C/C@200 C/C @150 C/C @150 C/C C17 3-T12 3-T12
1493
C15 C16 2L-T8
@200 C/C 2L-T8 2L-T8 2L-T8
B6:230x500 B7:230x500 @200 C/C @200 C/C @175 C/C
C20 C21
C19 B9:230x610 B10:230x610
B8:230x500

C18
FOR EXECUTION

3-T12 3-T12

3-T12 3-T12
1355
2L-T8 2L-T8 2L-T8 2L-T8
@175 C/C @200 C/C @200 C/C @175 C/C
C19 C5
B11:230x610 B12:230x610

2-T12
2-T12
500 500 500
500 3-T12 1480 1480
3-T12 Ld Ld Ld 3-T16 2-T12 3-T16
Ld
PROJECT:
3-T12 SURAJ SINGH
3-T12 1967 3-T12 1967 RESIDENTIAL BUILDING
C16
2L-T8 2L-T8 2L-T8
2L-T8 2L-T8 @150 C/C @200 C/C @150 C/C
@150 C/C @150 C/C C10
C17 B15:230x500 ARCHITECTS:
B14:230x500
B13:230x500
C6 UNIKNOWN ARCHITECTS
C20

CONSULTANT:

3-T12 3-T12 VIRAJ KUNKOLIENCAR


B.E. (Civil), AMIE, AIV

2-T12+1-T16 2-T12+1-T16 3-T12


1288 1877 1877 2L-T8 S. K. ASSOCIATES
2L-T8 2L-T8 @200 C/C
2L-T8 2L-T8 2L-T8 A11, SIXTH FLOOR, SILVIO HEIGHTS, ST. INEZ,
@200 C/C @175 C/C @175 C/C @200 C/C @175 C/C B18:230x610 C7
C21 C11 PANAJI - GOA 403001.
B16:230x610 C18 B17:230x610
(M):+91-9765848536 (E):viraj@sk-associatesgoa.com

SHEET CONTENT: ROOF SLAB BEAM DETAILS


ROOF BEAM LAYOUT
SCALE :1:75 CLIENT: SURAJ SINGH

DRAWN: SHARYU CHECKED: VIRAJ

DATE: 14.12.2023 SCALE: AS MENTIONED

DRAWING NO: SKA/51/07 REV NO: R0