You are on page 1of 2

DWG NO.

SH REV
ARV-HII-ELECT-038 1 XA
REVISIONS

NOTES: ZONE REV


ALL XA
DESCRIPTION
INITIAL RELEASE
DATE
03/09/12
APPROVED
SAS

1 WIRING ROUTING AND INSTALLATION PER MIL-W-5088 AND TM 1-1500-323-24-1.


ALL STRANDED WIRE SHALL CONFORM TO SAE AS22759/34,/43 SPEC UNLESS OTHERWISE SPECIFIED. /43 IS PREFERRED,
BUT 34 IS CONSIDERED ACCEPTABLE.
ALL SHIELDED WIRE SHALL CONFORM TO NEMA WC27500 SPEC USING STRANDED WIRE AS SPECIFIED ABOVE AND T23
OVER-JACKET.
UNLESS OTHERWISE NOTED, ALL WIRE TO BE 22AWG.
UNLESS OTHERWISE NOTED, JUMPERS SHALL NOT EXCEED 3" IN LENGTH.
LAST TWO DIGITS OF WIRE NUMBER DENOTES WIRE SIZE IN AWG.
BASIC SYMBOLOGY WILL BE AS FOLLOWS:
NEW WIRE/EQUIPMENT
EXISTING WIRE/EQUIPMENT
RELOCATED WIRE/EQUIPMENT
REMOVED WIRE
SINGLE SHIELDED WIRE \\\\\\\\\\\\\\\\\\\
TWO WIRE, TWISTED, SHIELDED
THREE WIRE, TWISTED, SHIELDED
W
B

W
B
O

2 WIRE NUMBERS TO BE PLACED ON OUTSIDE OF INSULATION AT INTERVALS NOT TO EXCEED 3 INCHES. HOT STAMPING
IS NOT PERMITTED.

3 CONNECTOR DESIGNATORS TO BE PERMANENTLY MARKED WITHIN 6" OF CONNECTORS.

4 CONNECTOR PINS DESIGNATED WITH AN UNDERLINED LETTER ARE LOWERCASE.

5 ALL BONDING AND GROUNDING SHALL BE IAW TM 1-1500-323-24-1 WP 017.

This drawing is the property of DynCorp


International and the Department of DynCorp International LLC
State. Any unauthorized use is strictly
prohibited. Contact PSD Technical
Library for information on revisions and
releases. INL/A Contract
UH-1HII AV/ELEC UPGRADE
28VDC AUX POWER
APPROVALS DATE
DRAFTER
M LAVERTY 11/01/11 WIRING DIAGRAM
CHECKER
J SMITH 01/20/12 SIZE CAGE CODE DRAWING NO. REV
DESIGNER
M LAVERTY 11/01/11
D 1SMB2 ARV-HII-ELECT-038 XA
ITAR EXPORT CONTROLLED
LIMITED ACCESS
ANALYST

RELEASED
xx/xx/xx
SCALE:
NONE SHEET
1 OF 2
DWG NO. SH REV
ARV-HII-ELECT-038 2 XA

OVERHEAD CB PANEL

J280 1
AUX PWR
28VDC A AUX1A18 10A
AUX PWR B AUX2A18N 4 28 VDC
3 2
ESS BUS

SIZE CAGE CODE DRAWING NO. REV

D 1SMB2 ARV-HII-ELECT-038 XA
NONE
SCALE: SHEET
2 OF 2