You are on page 1of 1

A B C C' D

1
B1-(9"X20")

B18-(9"X17")
B2-(9"X17")

B-12C(9"X23")

B-19C(9"X23")
B15-(9"X23")
B4-(9"X20")
B3-(9"X17")

IMPORTANT NOTE:
B5A-(9"X17") B5B-(9"X23") 1. THIS DRAWING IS UNDER COPY RIGHT OF STRUCTURAL ENGINEER.
2. ALL DRAWINGS ARE SUBJECT TO SANCTION FROM CONCERNED AUTHORITIES.
3 3. ANY DISCREPANCY IN THE DRAWING SHOULD BE IMMEDIATELY NOTICE TO THE
B-12B(9"X23")

STRUCTURAL ENGINEER.

B-19B(9"X17")
B16-(9"X17")
B11-(9"X23")

B14-(9"X17")
4. ALL WORKS TO BE CARRIED OUT STRICTLY AS PER DRAWINGS.
5. STRUCTURAL ENGINEER WILL BE NOT BE RESPONSIBLE FOR INCORRECT BAD OR
DEFECTIVE WORK.
6. THE DESIGNS ARE VALID ONLY WHEN PROPER CONSTRUCTION AND PRACTICE AND
QUALITY CONTROL ARE IMPLEMENTED IN THE SITE.
7. IF THE SOIL STRATA IN THE SITE ARE OBSERVED TO BE DIFFERENT FROM THOSE
MENTIONED I THE SOIL REPORT THE SAME SHOULD BROUGHT TO THE NOTICE OF
4 8. THE STRUCTURAL ENGINEER IMMEDIATELY FOR SUGGESTING MODIFICATION.
B6-(9"X17") B6B-(9"X23") 9.THE PROVISION MADE IN IS 456 2000,SP 34 AND OTHER RELEVANT CODES SHALL BE
STRICTLY ADHERED TO DURING EXECUTION.

B17-(9"X17")
10. ALL THE DIMENSIONS, LEVELS, ALIGNMENTS AND REINFORCEMENT BARS ETC. ARE TO BE
VERIFIED BEFORE THE CONCRETE IS PLACED FOR THE RCC MEMBERS.
11. LAP LENGTH IS EQUAL TO DEVELOPMENT LENGTH (Ld) WHEREVER LAPS ARE NEEDED.
LAPS SHALL BE STAGGERED AND NOT MORE THAN 50% AT ANY LOCATION.
12. MIX PROPORTION HAVE TO BE CONFIRMED WITH STRUCTURAL ENGINEER BEFORE

B-19A(9"X23")
B-12A(9"X23")

B13-(9"X23")

CONCRETING AND TO BE STRICTLY FOLLOWED.


13. STRUCTURAL ENGINEER HAS TO VERIFY AT EVERY STAGE BEFORE CONCRETING

B8-(9"X20")
B7-(9"X17")
PROJECT TITLE: PROPOSED RESIDENTIAL BUILDING AT MADHURAWADA NOTES :
1. ALL DIMENSIONS ARE IN FEETS AND INCHS
2. GRADE OF CONCRETE - M25
CLIENT: SUDHEER GARU 3. GRADE OF STEEL - Fe500
DRAWING TITLE: BLOCK-B TYPICAL BEAM LAYOUT 4. SBC OF SOIL CONSIDERED - 15t/m2
B9-(9"X17") REV: DESCRIPTION: BY: DATE:
5. STRUCTURE IS DESIGNED FOR S+G+4
6. CLEAR COVER FOR FOOTINGS - 2"
7. CLEAR COVER FOR COLUMNS - 1 1/2"
8. CLEAR COVER FOR BEAMS - 1"
9. CLEAR COVER FOR SLABS - 34"
B10-(9"X20")
PROJECT NO S-SP-1111/1112-03,04 ARCHITECT: STRUCTURAL ENGINEER:

6 DRAWING NO

DEALT BY
6
MURTHY
REV

DRAWN BY
R0
SBL PRO
CHECKED BY STRUCTURES
SCALE: N.T.S MURTHY
DATE: 17-06-2020 IMPACT architects H.NO. 50-1-48/1,
A S R NAGAR

TYPICAL ROOF BEAM LAYOUT


SEETHAMMADHARA,
VISAKHAPATNAM-530013.
This drawing is copyright and may not be copied without prior written consent. Phone: 9573249259