GENERAL NOTES:
1. ALL DIMENSIONS ARE IN FEETS AND INCHES.
2. DO NOT SCALE THE DRAWING, FOLLOW
WRITTEN DIMENSIONS ONLY.
3. THIS DRAWING IS TO BE READ IN
CONJUNCTION WITH ALL RELEVANT
ARCHITECTURAL, STRUCTURAL AND SERVICES
DRAWINGS.
4. LAP LENGTH AND DEVELOPMENT LENGTH
(Ld ) SHALL BE 50 TIMES THE DIAMETER OF BAR
(UNLESS NOTED OTHERWISE):-
5. FINE AND COARSE AGGREGATE SHALL
CONFIRM TO IS 383:1987.
6. CONSTRUCTION SHOULD BE IN
ACCORDANCE WITH IS 456-2000.
7. COVER TO REINFORCEMENT
*COLUMN & FOOTING :40MM
*EARTH FACE :50MM
*BEAM :30MM
*SLAB :25MM
8. USE VIBRATED REINFORCED CONCRETE OF MIX M20
FOR FOOTINGS, COLUMNS, BEAMS AND SLABS.
9. GRADE OF REINFORCING STEEL SHALL BE HYSD 500.
10. THIS BUILDING IS DESIGNED FOR GROUND +
2 FLOOR ONLY. (i.e., 3 SLABS)
11. SBC OF SOIL IS TAKEN AS 28 t/sqm. (280 kN/sqm.)
12. IF ANY VARIATION IN SOIL STRATA FOUND DURING
EXECUTION OF THE FOUNDATION SOILS, WHEN
COMPARED WITH THE CONSIDERED STRATA IT
SHOULD BE BROUGHT TO THE NOTICE OF ENGINEER
INCHARGE OR CONSULTANT FOR REVISION.
13. CONSTRUCTION SHALL BE DONE AFTER
APPROVAL OF SHOP DRAWINGS FROM THE
STRUCTURAL CONSULTANTS.
14. CORRELATE WITH THE RELAVENT DRAWINGS FOR
NECESSARY DETAILS.
15. ALL VOIDS IN SUB STRATA SHOULD BE FILLED
UP WITH PLUM CONCRETE M-15
TYPICAL SLAB LAYOUT PLAN #05