You are on page 1of 298

© Siemens AG 2009

SITRANS L
Level instruments

5/2 Product overview Continuous level measurement


(continued)
Point Level measurement
Capacitance transmitters
5/6 Capacitance switches
5/253 SITRANS LC300
5/9 Pointek CLS100
5/262 SITRANS LC500
5/15 Pointek CLS200
5/285 SITRANS LC300 and LC500 specials
5/31 Pointek CLS300
Hydrostatic
5/47 Pointek CLS500
Sec.2 via SITRANS P
5/62 Pointek Specials
Vibrating switches Continuous measurement - Open
5/64 SITRANS LVL100 channel flow
5/69 SITRANS LVL200 Ultrasonic controller
5/83 SITRANS LVS200 5/286 OCM III
Rotating paddle switches
Communications and Displays
5/92 SITRANS LPS200
5/289 SmartLinx modules
5/101 Ultrasonic switch
5/291 Dolphin Plus Software
5/104 Pointek ULS200
5/292 SITRANS RD100
Continuous level measurement 5/294 SITRANS RD200
Ultrasonic transmitters
5/108 The Probe
5/111 SITRANS Probe LU
Ultrasonic controllers
5/115 HydroRanger 200
5/120 MultiRanger 100/200
5/124 HydroRanger Plus
5/128 SITRANS LUC500
5/132 SITRANS LU01 and LU02
5/137 SITRANS LU10
5/140 SITRANS LU SAM
5/142 SITRANS LU AO
5/144 Ultrasonic transducers
5/145 ST-H
5/148 Echomax XRS-5
5/151 Echomax XPS and XCT
5/161 Echomax XLT
Accessories for ultrasonic
5/164 EA aiming devices
5/166 FMS mounting brackets
5/167 TS-3 temperature sensor
5/169 Radar transmitters
5/173 SITRANS Probe LR
5/177 SITRANS LR200
5/188 SITRANS LR250
5/195 SITRANS LR260
5/200 SITRANS LR300
5/209 SITRANS LR200 and SITRANS LR300
Antennas
5/214 SITRANS LR400
5/221 SITRANS LR460
5/226 SITRANS LR260/LR460 Specials
Guided wave radar transmitters
5/230 SITRANS LG200

You can download all instructions, cata-


logs and certificates for SITRANS L free
of charge at:
www.siemens.com/level

March 2009 Siemens FI 01 · 2009 US Edition


© Siemens AG 2009

Level instruments
Product overview
Product overview

■ Overview
Application Device description Page Programming
Software
Point level measurement - Capacitance switches
Powerful range of level Pointek CLS100/CLS200/CLS300/CLS500
switches suitable for a variety • CLS100: compact 2-wire inverse frequency shift ca- 5/9 –
of industries pacitance switch for level detection in constricted
spaces, interfaces, solids, liquids, slurries, and foam
• CLS200: a versatile inverse frequency shift capaci- 5/15 SIMATIC PDM
tance level switch with optional rod/cable choices
and configurable output, ideal for detection of liq-
uids, solids, slurries, foam, and interfaces; digital
version (with PROFIBUS PA) includes a display and
provides additional diagnostic features
• CLS300: inverse frequency shift capacitance level 5/31 SIMATIC PDM
switch with optional rod/cable choices and config-
urable output. It is ideal for detecting liquids, solids,
slurries, foam and interfaces in demanding condi-
tions where high pressure and temperatures are
present; digital version (with PROFIBUS PA) includes
a display and provides additional diagnostic features
• CLS500: inverse frequency shift capacitance level 5/47 SIMATIC PDM
switch for detecting interfaces, solids, liquids, toxic
and aggressive chemicals in critical conditions of

5 high temperature and pressure; HART® communica-


tion for remote commissioning
Point level measurement - Vibrating switches
Effective vibrating point level SITRANS LVL100/LVL200
switches for liquid and slurry • LVL100: compact vibrating level switch for use in liq- 5/64 –
applications uid applications such as overflow, high, low and de-
mand applications –
• LVL200: standard vibrating level switch for use in 5/69
liquid, slurry, and liquid hazardous applications such
as overflow, high, low and demand applications;
SIL-2 certified
Reliable vibrating point level SITRANS LVS200
switches for bulk solids at a • LVS200: vibrating point level switch with unique ro- 5/83 –
competitive price bust tine design, for use on bulk solids

Point level measurement - Rotating paddle switches


Reliable rotating point level SITRANS LPS200
switches for bulk solids at a • LPS200: rotating switch that detects high, low and 5/92 –
competitive price demand conditions for bulk solids

Point level measurement - Ultrasonic switch


Ultrasonic non-contacting Pointek ULS200 5/104 –
switch with two switch points • Rugged design, no moving parts and virtually main-
for level detection of bulk tenance-free
solids, liquids and slurries in
a wide variety of industries • Transducer available in ETFE or PVDF copolymer
and therefore inert to most chemicals

Continuous measurement - Ultrasonic transmitters


Compact level transmitter with The Probe 5/108 –
integrated transducer for • Simple, compact and competitively priced ultrasonic
accurate level measurement level transmitter in several versions for maximum ver-
for liquid applications satility:
- Three-wire system with 5 m model 24 V DC
- Two-wire system with current loop

2-wire loop powered ultra- SITRANS Probe LU 5/111 SIMATIC PDM


sonic transmitter for level, vol- • Continuous level measurement up to 12 m (40 ft)
ume, and flow monitoring of range
liquids in open channels, stor-
age vessels, and simple pro- • Patented Sonic Intelligence signal processing
cess vessels • Extremely high signal-to-noise ratio
• Auto False-Echo Suppression of false echoes

5/2 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Product overview
Product overview
Application Device description Page Programming
Software
Continuous measurement - Ultrasonic controllers
Ultrasonic level controller for HydroRanger 200 5/115 SIMATIC PDM
up to six pumps - control, dif- • An economical, low-maintenance solution delivering
ferential control and open control efficiency and productivity needed to meet
channel flow monitoring today’s exacting standards
• Auto False-Echo Suppression of false echoes
Versatile short- to medium- MultiRanger 100/200 5/120 SIMATIC PDM
range ultrasonic single- and • Using non-contacting ultrasonic technology, the con-
dual-vessel level controller for troller measures the level in short to medium range
virtually any application in a applications up to 15 m (50 ft) of solids, liquids or
wide range of industries slurries
• Auto False-Echo Suppression of false echoes
Non-contacting, cost-effec- HydroRanger Plus 5/124 Dolphin Plus
tive solution for reliable con- • Available as 19" rack, for panel mounting or in wall
trol of level and flow enclosure
measurements in water and
wastewater applications • Compatible with Echomax® ultrasonic transducers

Complete ultrasonic level SITRANS LUC500 5/128 Dolphin Plus


controller for monitoring and
control of water distribution
and wastewater collection
• Monitoring and control in one device
• Integral telemetry interface (Modbus® RTU/ASCII) 5
systems, with energy-saving • Expandable platform to handle any liquid application
algorithms from tank level measurement to pump control

Ultrasonic long-range level SITRANS LU01/LU02/LU10 5/132, Dolphin Plus


monitoring system for liquids • Automatic conversion of level into volume for stan- 5/137
and solids dard or custom tank shapes
• Easy to install and program
• Optional fieldbus card, e.g. PROFIBUS DP

Output modules for SITRANS SITRANS LU SAM/SITRANS LU AO


LU10 • SITRANS LU SAM satellite alarm module provides up 5/140 –
to 20 relay contacts for the measurement points con-
nected to a SITRANS LU10
• SITRANS LU AO analog output module provides re- 5/142 –
mote analog outputs for the measurement points of
the SITRANS LU10 transceiver
Continuous measurement - Ultrasonic transducers
ST-H: ETFE or PVDF trans- ST-H/Echomax XRS-5
ducer for chemicals • The narrow design of the ST-H allows the sensor to 5/145 –
XRS-5: Standard transducer be mounted using a 2" connection
for applications to 8 m (26 ft) • XRS-5: narrow beam angle of only 10°, measuring 5/148 –
range maximum 8 m (26 ft) for measurement of liq-
uids, solids and slurries

Transducers for liquids and Echomax XPS and XCT/XLT


bulk solids • XPS series offers versions for various distances up to 5/151 –
XPS and XCT series: Hermeti- 40 m (130 ft) and up to a max. temperature of +95 °C
cally sealed PVDF enclosure (+203 °F)
for chemical immunity • XCT series for applications at high temperatures, for –
XLT: Designed for high tem- measurement of levels at distances up to 12 m (40 ft)
perature and long range and temperatures of max. +145 °C (+293 °F)
applications • XLT: measuring ranges from 0.9 to 60 m (1.8 to 200 ft) 5/161 –
and temperatures up to +150 °C (+302 °F). Beam an-
gle of just 5° provides accurate readings in solids
storage bunkers

March 2009 Siemens FI 01 · 2009 US Edition 5/3


© Siemens AG 2009

Level instruments
Product overview
Product overview
Application Device description Page Programming
Software
Continuous measurement - Radar transmitters
2-wire, 6 GHz pulse radar SITRANS Probe LR 5/173 SIMATIC PDM
level transmitter for continu- • Uni-Construction polypropylene rod antenna stan-
ous monitoring of liquids and dard
slurries in storage vessels
with nominal pressure and • Patented Sonic Intelligence signal processing
temperature, to a range of • Auto False-Echo Suppression of false echoes
20 m (66 ft)

2-wire, 6 GHz pulse radar SITRANS LR200 5/177 SIMATIC PDM


level transmitter for continu- • Program without opening the lid, even in hazardous
ous monitoring of liquids and areas, using patented infrared IS handheld program-
slurries in storage and pro- mer
cess vessels including high
temperature and pressure, to • Special Uni-Construction hermetically sealed
a range of 20 m (66 ft) polypropylene rod antenna has integrated threaded
connection
• Built-in alphanumeric display with support in four lan-
guages

2-wire, 25 GHz pulse radar SITRANS LR250 5/188 SIMATIC PDM


level transmitter for continu- • Simple operation using the graphical local user inter-
5 ous monitoring of liquids and
slurries in storage and pro-
cess vessels including high
face (LUI)
• Plug-and-play setup using the intuitive Quick Start
temperature and pressure, to Wizard
a range of 20 m (66 ft); ideal • 25 GHz high frequency allows for small horn anten-
for small vessels and low nas and easy mounting in nozzels
dielectric media
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Sup-
pression of fixed obstructions
• Communication using HART® or PROFIBUS PA
2-wire, 25 GHz pulse radar SITRANS LR260 5/195 SIMATIC PDM
level transmitter for continu- • Simple operation using the graphical local user inter-
ous monitoring of solids up to face (LUI)
30 m (66 ft); ideal for mea-
surement in extreme dust • Plug-and-play setup using the intuitive Quick Start
Wizard
• 25 GHz high frequency allows for small horn anten-
nas and easy mounting in nozzels
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Sup-
pression of fixed obstructions
• Communication using HART® or PROFIBUS PA
4-wire, 6 GHz pulse radar SITRANS LR300 5/200 SIMATIC PDM
level transmitter for continu- • Cost-effective level measurements with powerful ra-
ous monitoring of liquids and dar measuring system for process and tank control in
slurries in storage and pro- extremely difficult processes and atmospheres
cess vessels including high
temperature and pressure, to • Reliable level measurements in liquids and slurries
a range of 20 m (66 ft) up to 20 m (65 ft)
4-wire, 24 GHz FMCW radar SITRANS LR400 5/214 SIMATIC PDM
level transmitter for continu- • Minimum maintenance requirements and wear as re-
ous monitoring of liquids and sult of non-contacting measuring principle
slurries in storage and pro-
cess vessels including high • High long-term stability resulting from self-calibration
temperature and high pres- with highly stable internal reference
sure, to a range of 50 m • High measuring accuracy and repeatability as result
(164 ft); ideal for low dielectric of 24 GHz; narrow beam angle for tall, narrow vessels
media
4-wire, 24 GHz FMCW radar SITRANS LR460 5/221 SIMATIC PDM
level transmitter with • Process Intelligence for advanced signal processing
extremely high signal-to-noise and quick and easy adjustment
ratio and advanced signal
processing for continuous • Self-guided Quick Start Wizard for plug and play
monitoring of solids up to start-up
100 m (328 ft); ideal for mea- • 100 m (328 ft) range for long-range and difficult ap-
surement in extreme dust plications

5/4 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Product overview
Product overview
Application Device description Page Programming
Software
Continuous measurement - Guided wave radar transmitters
Guided wave radar transmit- SITRANS LG200 5/230 SIMATIC PDM
ter for short- and medium- • Measures accurately on materials with dielectric (dK)
range level, level/interface as low as 1.4
and volume measurement of
liquids and solids. It is unaf- • Guided wave radar measurement for up to 2.5 mm
fected by changes in process (0.12") accuracy
conditions, high tempera- • Measures level and interface on challenging appli-
tures and pressures, and cations including foam
steam.
• 3 button programming for quick setup
• Reliable level measurement on harsh applications
with pressure up to 430 bar g (6250 psi g) and tem-
peratures as high as +427 °C (+800 °F)
Continuous level – Capacitance transmitters
For liquids and solids applica- SITRANS LC300 5/253 –
tions, ideal for standard • Sophisticated, but easy-to-adjust microprocessor
industrial applications in combined with field-proven probes
chemical, hydrocarbon pro-
cessing, food and beverage • Patented active shield technology ensures measure-
and mining, aggregate and ments are unaffected by vapors, product deposits,
cement industries dust and condensation

5
Level and interface transmit- SITRANS LC500 5/262 SIMATIC PDM
ter for extreme and critical • Equipped with the HART® Smart protocol for remote
process conditions, such as setup and calibration
oil and liquid natural gas
(LNG), toxic and aggressive • Patented active shield technology ensures measure-
chemicals and vapours ments are unaffected by vapors, product deposits,
dust and condensation

Continuous level - Open channel flow - Ultrasonic controller


High accuracy ultrasonic flow OCM III 5/286 –
monitor for open channels • Compatible with most standard open channel weirs
and flumes
• AC and DC operation
• Automatically switches to battery operation for unin-
terrupted power
• MCERTS approved device
Communications and Displays
SmartLinx Module, Dolphin Plus software
• Optional communication modules, SmartLinx, pro- 5/289 –
vide direct digital connection to popular industrial
fieldbus systems
• Dolphin Plus for quick and easy configuring, monitor- 5/291 –
ing, tuning and diagnostics of Siemens devices

2-wire loop powered, NEMA SITRANS RD100 5/292 –


4X enclosed remote digital • Versatile loop-powered meter that displays process
display for process instrumen- variables in level, flow, pressure, temperature and
tation weighing applications
• FM and CSA approved device that can be installed
in range of environments, including hazardous areas
• Large, easy-to-read display
• Easy to install and set up using quick two-step pro-
cess
Universal input, panel mount SITRANS RD200 5/294 –
remote digital display for pro- • Universal remote display that accepts various inputs,
cess instrumentation making it an ideal fit for use with most field instru-
ments
• Standard panel mount display with optional enclo-
sures
• Two optional relays for alarm indication or process
control applications
• Meter Copy feature to reduce setup time, cost and
errors
• RD Software supporting remote configuration, moni-
toring and logging for up to 100 displays

March 2009 Siemens FI 01 · 2009 US Edition 5/5


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Capacitance

■ Overview ■ Mode of operation


Introduction Common Terms
Inverse frequency shift capacitance point level switches and Capacitance
continuous level transmitters are designed to withstand the
harsh environments of high pressure and high temperature ap- The property of a system of conductors and dielectrics that per-
plications. mits the storage of electricity when a potential difference exists
between the conductors. Its value is expressed as the ratio of a
Inverse Frequency Technology quantity of electricity to a potential difference and the unit is a
Farad.
Siemens inverse frequency shift capacitance devices incorpo-
rate a unique frequency-based approach to level measurement. Capacitor
The capacitance units monitor the effect of capacitance based A device in a circuit that has the potential to store an electric
on frequency change. The relationship between capacitance charge. Typically a capacitor has 2 conductors or electrodes
and frequency is inverse. Because small level changes result in separated by a layer of a non-conducting material called a di-
a large frequency change, the result is excellent resolution and electric. With the conductors on opposite sites of the dielectric
accuracy. layer oppositely charged by a source of voltage, the electrical
Principle of Operation energy of the charged system is stored in the polarized dielec-
tric.
Inverse frequency shift capacitance devices require two compo-
nents: a reference electrode of a variable capacitor and the Dielectric constant
measurement electrode. In capacitive level measurement, the The ability of a dielectric to store electrical potential energy un-
environment (typically the vessel wall) acts as the reference der the influence of an electric field. This is measured by a ratio
electrode, while the probe supplies the measurement electrode. which compares the capacitance of a condenser with the mate-
The dielectric is composed of the vessel contents and, if the rial as dielectric to its capacitance with a vacuum/dry air as di-
5 measurement electrode is insulated, the insulating layer. electric: the dielectric constant of air is 1.
Active shield
The portion of the probe isolated from the active measurement
section. The sensor signal is connected to the active shield por-
tion of the probe, eliminating the electrical potential difference
between the shield and the measurement section. So, the shield
portion of the probe near the process connection is not affected
by changes in vapour concentration, material buildup, dust or
condensation.

Inverse frequency shift capacitance operation


Capacitance is affected by the surface area of the electrodes,
the separation distance between the electrodes and the dielec-
tric constant of the vessel contents. The dielectric constant is the
measure of a material’s ability to store energy. The relative di-
electric constant of air (vacuum) is 1; all other materials have a
higher value.

5/6 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Capacitance

■ Technical specifications
Point Level Measurement Continuous Level/
Interface Measurement
Criteria Pointek CLS100 Pointek CLS200 Pointek CLS300 Pointek CLS500 SITRANS LC300 SITRANS LC500
Typical applications Liquids, slurries, Liquids, slurries, Liquids, slurries, Water in oil level, Conductive or non- Water in oil, foam or
powders, granules, powders, granules, powders, granules, foam or liquid/ foam conductive liquids, liquid/foam level,
applications in con- foam, food and relatively high pres- level, glycol regen- foam or liquid/foam high-pressure coa-
stricted spaces pharmaceuticals, sure and tempera- erators, high-pres- levels, water in oil lescers, LNG (Liqui-
petrochemicals ture, hazardous sure coalescers levels fied Natural Gas)
areas
Max. length includ- 100 mm (4") Rod: 5.5 m (18 ft) Rod: 1 m (40") Rod: 1 m (40") Rod: 5 m (18 ft) Rod: 5.5 m (18 ft)
ing sensor Cable: up to 30 m Cable: 25 m (82 ft) Cable: 25 m (82 ft) Cable: 35 m (115 ft)
(98 ft)
Process tempera- • Stainless steel • -40 to +85 °C • -40 to +200 °C • -50 to +200 °C -40 to +200 °C • -50 to +200 °C
ture (Temperature process connec- (-40 to +185 °F) (-40 to +392 °F) (-58 to +392 °F) (-40 to +392 °F) (-58 to +392 °F)
ratings are pressure tion: • With temp. ext.: • HT version: • HT version: • Option:
dependent. -30 to +100 °C -40 to +125 °C -40 to +400 °C -60 to +400 °C -60 to +400 °C
See Pressure/Tem- (-22 to +212 °F) (-40 to +257 °F) (-40 to +752 °F) (-76 to +752 °F) (-76 to +752 °F)
perature curves for • PPS process con-
respective prod- nection:
uct.) -10 to +100 °C
(+14 to +212 °F)
Process pressure Up to 10 bar g • Rod and ext. ver- Up to 35 bar g • Up to 150 bar g Up to 35 bar g • Up to 150 bar g
(Pressure ratings (146 psi g) sions: (511 psi g) (2175 psi g) (511 psi g) (2175 psi g)
are temperature
dependent. See
Up to 25 bar g
(365 psi g)
• HP version:
Up to 345 bar g
• Option:
Up to 345 bar g
5
Pressure/Tempera- • Cable version: (5004 psi g) (5004 psi g)
ture curves for Up to 10 bar g
respective prod- (146 psi g)
uct.)
Output • 4 or 20/20 or 4 mA CLS200 Standard: CLS300 Standard: • 4 to 20/20 to 4 mA 4 to 20/20 to 4 mA • 4 to 20/20 to 4 mA
2-wire current 1 SPDT Form C 1 SPDT Form C 2-wire current 2-wire current loop 2-wire current
loop relay, solid-state relay, solid-state loop loop
• Solid-state output switch switch • Solid-state switch • Solid-state switch
(stainless steel CLS200 Digital: CLS300 Digital:
cable or enclo- solid-state switch solid-state switch
sure version) included included
• Relay output (ful-
ly-synthetic ver-
sion)
Communications • CLS200 Standard: • CLS300 Standard: HART, SIMATIC HART, SIMATIC
3 LED indicators 3 LED indicators PDM compatible PDM compatible
• CLS200 Digital: • CLS300 Digital:
PROFIBUS PA; PROFIBUS PA;
SIMATIC PDM SIMATIC PDM
compatible compatible
Power Specifica- • Standard: • CLS200 Standard: • CLS300 Standard: • 12 to 33 V DC 12 to 32 V DC any • 12 to 33 V DC
tions 12 to 33 V DC 12 to 250 V 12 to 250 V • 3.6 to 22 mA/ polarity, 2-wire cur- • 3.6 to 22 mA/
• Intrinsically Safe: AC/DC, 0-60 Hz, AC/DC, 0-60 Hz, 22 to 3.6 mA rent loop circuit 22 to 3.6 mA
10 to 30 V DC 2 W max. 2 W max. (2-wire current (2-wire current
• CLS200 Digital: • CLS300 Digital: loop) loop)
- bus voltage: - bus voltage:
12 to 30 V DC, 12 to 30 V DC,
IS version IS version
12 to 24 V DC 12 to 24 V DC
- current con- - current con-
sumption: sumption:
12.5 mA 12.5 mA
Approvals CE, CSA, FM, CE, CSA, FM, CE, CSA, FM, CE, CSA, FM, CE, CSA, FM, CE, CSA, FM,
ATEX, C-TICK, ATEX, C-TICK, ATEX, C-TICK, ATEX, C-TICK, ATEX, C-TICK, ATEX, C-TICK,
Lloyds Register, Lloyds Register, Lloyds Register, Lloyds Register Lloyds Register Lloyds Register
WHG WHG WHG Current Signalling Current Signalling Current Signalling
according to according to according to
NAMUR NE 43 NAMUR NE 43 NAMUR NE 43

March 2009 Siemens FI 01 · 2009 US Edition 5/7


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Capacitance

Capacitance Application Questionnaire


Customer information
Contact: Prepared By:
Company: Date:
Address: Notes on the Application:
City: Country:
Zip/Postal Code: Phone: ( )

E-mail: Fax: ( )

Tank/Vessel Information (Supply sketch where possible) Sketch attached

Type: Storage Tank construction: Dimensions:

5
Metallic Non-metallic Height: m/ft
Process
Agitated top, bottom or side
Width/Diameter: m/ft
Separator
Pressure:
FPSO Normal: Critical Information
(Floating Processing
Storage and Offloading) Maximum (relief): Nozzle Length: cm/in
Tank top: Open Tank bottom: Sloped Mounting: Top Mount Nozzle Diameter: cm/in
Flat Flat Side Mount
Conical Conical Pipe Mount
Parabolic Parabolic

Process Data
Material being measured: Liquid Solid Slurry

Material temperature: Norm: °C/°F Max: °C/°F


Measurement type: Point level
Constant dielectric: No Yes DK Value
Continuous level

Upper material: DK Value


Interface level
Lower material: DK Value

Process pressure: Min. Max.

Coating build-up: No Yes Conductive material: No Yes DK Value

Installation (indicate all that apply)

Power available:

Outputs required: Communications

4 to 20 mA Relay Solid state HART ® / 4 to 20 mA PROFIBUS PA

Products recommended:
© Siemens Milltronics Process Instruments Inc. www.siemens.com/processautomation Form# 2-770R4

5/8 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS100

■ Overview ■ Configuration

Pointek CLS100 is a compact 2-wire inverse frequency shift ca-


pacitance switch for level detection in constricted spaces, inter-
faces, solids, liquids, slurries and foam.

■ Benefits 5
• Easy installation with verification by built-in LED
• Low maintenance with no moving parts
• Sensitivity adjustment
• Integrated cable or PBT enclosure versions available
• Intrinsically Safe, Dust Ignition Proof and General Purpose op-
tions available

■ Application
Pointek CLS100’s short insertion length of 100 mm (4") and ver-
satility in various applications and in vessels or pipes makes it a Pointek CLS100 installation
good replacement for traditional capacitance sensors.
Its advanced tip-sensing technology provides accurate, repeat-
able switchpoint performance. The PPS (Polyphenylene sulfide)
probe [optional PVDF (Polyvinylidene Fluoride)] is chemically re-
sistant with an effective process operating temperature range
from -30 to +100 °C (-22 to +212 °F) (7ML5501), and -10 to
+100 °C (+14 to +212 °F) (7ML5610). The fully potted design en-
sures reliability in a vibrating environment such as agitated tanks
up to 4 g. When used with a SensGuard protection cover, the
CLS100 is protected from shearing, impact and abrasion in
tough primary processes.
The Pointek CLS100 is available in three versions. The integral
cable version has a stainless steel process connection and
probe options of PPS or PVDF. The fully synthetic version has a
thermoplastic polyester enclosure with a PPS process connec-
tion combined with a PPS probe. The standard enclosure version
has a thermoplastic polyester enclosure with a stainless steel
process connection in combination with a PPS or PVDF probe.
• Key Applications: liquids, slurries, powders, granules, food
and pharmaceuticals, chemicals, hazardous areas

March 2009 Siemens FI 01 · 2009 US Edition 5/9


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS100

■ Technical specifications
Stainless steel process connection (integral cable Synthetic process connection (fully synthetic
or enclosure version) (7ML5501) enclosure version only) (7ML5610)
Mode of operation
Measuring principle Inverse frequency shift capacitive level detection Inverse frequency shift capacitive level detection
Input
Measured variable Change in picoFarad (pF) Change in picoFarad (pF)
Output
Output signal
• Alarm output 4 or 20/20 or 4 mA 2-wire loop 4 or 20/20 or 4 mA 2-wire loop
• Switch output1) Solid-state: 30 V DC/30 V AC, max. 82 mA Max. switching voltage: 60 V DC/30 V AC
Max. switching current: 1 A
• Fail-safe mode Min. or max. Min. or max.
Accuracy
Repeatability 2 mm (0.08") 2 mm (0.08")
Rated operating conditions2)
Installation conditions
• Location Indoor/outdoor Indoor/outdoor

5 Ambient conditions
• Ambient temperature -30 to +85 °C (-22 to +185 °F) -10 to +85 °C (+14 to +185 °F)
• Installation category I I
• Pollution degree 4 4
Medium conditions
• Relative dielectric contant εr Min. 1.5 Min. 1.5
• Temperature -30 to +100 °C (-22 to +212 °F) -10 to +100 °C (+14 to +212 °F)
• Pressure (vessel) -1 to +10 bar g (-14.6 to +146 psi g), nominal2) -1 to +10 bar g (-14.6 to +146 psi g), nominal
• Degree of protection
- Enclosure version IP68/Type 4/NEMA 4 IP68/Type 4/NEMA 4
- Integral cable version IP65/Type 4/NEMA 4 Not applicable
• Cable inlet ½" NPT (M20x1.5 optional) ½" NPT (M20x1.5 optional)
Design
Enclosure/Integral cable version Fully synthetic version
• Material
- Body (Enclosure version) Thermoplastic polyester Thermoplastic polyester
- Lid (Enclosure version) Transparent thermoplastic polycarbonate (PC) Transparent thermoplastic polycarbonate (PC)
- Integrated cable body (Integral ca- 316L stainless steel Not applicable
ble version)
• Sensor length (nominal) 100 mm (4") 100 mm (4")
• Process connection material of Connection: 316L stainless steel; PPS process connection and PPS sensor
probe/wetted parts Process seal: FKM (optional FFKM); (Uni-Construction)
Sensor: PPS (optional PVDF)3)
• Connection (Enclosure version) Internal 5-point terminal block, ½" NPT wiring Removable internal 5-point terminal block, ½" NPT
entrance, M20x1.5 optional wiring entrance, M20 x 1.5 optional
• Connection (Integral cable version) 4 conductors, 1 m (3.3 ft), 0.5 mm² (22 AWG), Not applicable
shielded, polyester jacket
• Process connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] ¾" NPT [(Taper), ANSI/ASME B1.20.1]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
Power supply
• Standard 12 to 33 V DC 12 to 33 V DC
• Intrinsically Safe 10 to 30 V DC (Intrinsically Safe barrier required) Not applicable

5/10 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS100
Stainless steel process connection (integral cable Synthetic process connection (fully synthetic
or enclosure version) (7ML5501) enclosure version only) (7ML5610)
Certificates and approvals • General: CE • General: CE
• Marine: Lloyds Register of Shipping, categories • Marine: Lloyds Register of Shipping, categories
ENV1, ENV2, and ENV5 ENV1, ENV2, and ENV5
Dust Ignition Proof (barrier required): CSA/FM Class • Dust Ignition Proof: ATEX II 1D 1/3D T107 °C
II and III, Div. 1, Groups E, F, G T4
• Overfill protection: WHG (Germany)
• Intrinsically Safe (barrier required): CSA/FM Class I,
II and III, Div. 1, Groups A, B, C, D, E, F, G T4 • C-TICK (Australia)
• ATEX II 1 GD 1/2GD EEx ia IIC T4 to T6 T107 °C
• Overfill protection: WHG (Germany)
• C-TICK (Australia)
1)
When synthetic process connection version (7ML5610) is used in wet locations, switching voltage of the relay is limited to 35 V DC/16 V AC.
2)
When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on
page 5/13.
3)
When FFKM O-ring (Option A22) is selected, process temperature is restricted to -20 °C (-4 °F)

March 2009 Siemens FI 01 · 2009 US Edition 5/11


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS100

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS100, stainless steel process con- C) 7 M L 5 5 0 1 - Pointek CLS100, PPS process connection C) 7 M L 5 6 1 0 -
nection Compact 2-wire inverse frequency shift capaci-
0 7 7 77 0 7 7 77
Compact 2-wire inverse frequency shift capaci- tance switch for level detection in constricted
tance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and
spaces, interfaces, solids, liquids, slurries and foam
foam
Process connection (PPS)
Process connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] A
¾" NPT [(Taper), ANSI/ASME B1.20.1] A (PPS probe body)
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] B
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] J (PPS probe body)
Approvals Approvals
General Purpose A General Purpose A
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, C ATEX II 1D 1/3D T107 °C C
E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to T6 Versions/Options
T107 °C
Enclosure version, PPS process connection, 1
CSA/FM Class II and III, Div. 1, Groups E, F, G G ½" NPT cable inlet
Device version Enclosure version, PPS process connection, 2
Integral cable version (PPS probe) 1 M20x1.5
Enclosure version (PPS probe), ½" NPT cable inlet 3 WHG approval, German overfill protection
Integral version with PVDF probe body 5 Not required 0
Enclosure version with PVDF probe body (½" NPT 6 Required 1
cable inlet)
5
Instruction manual
Enclosure version (PPS probe), M20x1.5 cable inlet 7 Quick start manual, multi-language 7ML1998-5QJ81
Enclosure version with PVDF probe body, M20x1.5 8 Note: due to ATEX regulations one Quick start man-
cable inlet ual is included with every product
WHG approval, German overfill protection This device is shipped with the Siemens Milltronics
Not required 0 manual CD containing ATEX Quick Starts and
instruction manuals.
Required 1
Accessories
Further designs Order code
Sensguard, ¾" NPT (PPS) 7ML1830-1DL
Please add "-Z" to Order No. and specify Order Only available for CLS100 with ¾" NPT thread
code(s). Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM
FFKM seal O-ring1) A22 Only available for CLS100 with ¾" NPT thread
Inspection Certificate Type 3.1 per EN 10204 C12 Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
text line, suitable for enclosures
Instruction manual Order No.
Quick start manual, multi-language 7ML1998-5QJ81
Note: due to ATEX regulations one Quick start man-
ual is included with every product.
This device is shipped with the Siemens Milltronics ■ Options
manual CD containing ATEX Quick Starts and
instruction manuals.
Optional equipment
Sensguard, ¾" NPT (PPS) 7ML1830-1DL
Only available for CLS100 with ¾" NPT thread
Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM
Only available for CLS100 with ¾" NPT thread
Tag, Stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
text line, suitable for enclosure
Siemens Intrinsically Safe Barrier (DC powered), 7NG4122-1AA10
ATEX II 1 G EEx ia
½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA
diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 °C
(-40 to +212 °F), IP68 (General Purpose)
M20x1.5 cable gland, PA polyamide, ATEX II 2G 7ML1830-1JC
EEx e II, fits cable diameter 7 to 12 mm (0.28 to
0.47"), -20 to +70 °C (-4 to +158 °F), IP68 Optional Sensguard dimensions
(General Purpose)
1)
See Temperature restriction on page 5/13
C) Subject to export regulations AL: N, ECCN: EAR99

5/12 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS100

■ Characteristic curves

Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C

-30 ºC
(-22 ºF)
T

Pressure/Temperature Curve
5
CLS100 (7ML5501)
Threaded Process Connections

P = Permitted Operating Pressures


T = Permitted Operating Temperature

Pointek CLS100 Process Pressure/Temperature derating curves

■ Dimensional drawings

Pointek CLS100 dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/13


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS100

■ Schematics

Pointek CLS100 connections

5/14 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

■ Overview ■ Configuration

Pointek CLS200 is a versatile inverse frequency shift capaci-


tance level switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, slurries, foam
and interfaces. The digital version (with PROFIBUS PA) includes
a display and provides additional diagnostic features. 5
■ Benefits
• Potted construction protects signal circuit from shock, vibra-
tion, humidity and/or condensation
• High chemical resistance
• Level detection independent of tank or pipe earth reference
• Insensitive to product buildup due to high frequency oscilla-
tion
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy setup of CLS200 when
you can configure switching threshold, even under the most
demanding process conditions (digital version only)
• Extended rod, cable and sanitary versions available
• Standard version: 3 LED indicators for sensor status, output
status and power
• SIL/IEC61508 compliant for use in safety integrated level ap-
plications for overfill protection (SIL-2)
• Digital version: integral LCD display, and PROFIBUS PA com-
munication

■ Application
The Pointek CLS200 is offered in standard and digital versions.
Pointek CLS200 installation
The standard version has 3 LED indicators with basic relay and
solid-state switch alarms.
The digital version provides an integral LCD display for stand-
alone use, and also provides PROFIBUS PA communication
(Profile version 3.0 (P caps)) for connection to a network.
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 250 V AC/DC for standard version and
12 to 30 V DC for digital version). The stainless steel and PPS
(PVDF optional) materials used in the probe construction pro-
vide a temperature rating up to +125 °C (+257 °F) on the pro-
cess wetted portion of the probe. The switch responds to any
material with a dielectric constant of 1.5 or more by detecting a
change in oscillating frequency, and it can be set to detect be-
fore contact or on contact with the probe.The CLS200 operates
independently of the tank wall or pipe so it does not require an
external reference electrode for level detection in a non-conduc-
tive vessel such as concrete or plastic.
• Key Applications: liquids, slurries, powders, granules, pres-
surized applications, hazardous areas

March 2009 Siemens FI 01 · 2009 US Edition 5/15


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

■ Technical specifications • Pressure (cable version) -1 to +10 bar g/


-14.6 to +150 psi g (nominal)
(Note: all specifications listed below apply to Standard and Digital ver- • Pressure (optional sliding coupling -1 to +10 bar g/
sions unless otherwise noted) version) -14.6 to +150 psi g (nominal)
Mode of operation Design
Measuring principle Inverse frequency shift capaci- • Material
tive level detection
- Enclosure Epoxy-coated aluminum with gas-
Input ket
Measured variable Change in picoFarad (pF) - Optional thermal isolator 316L stainless steel
Output • Connection Removable terminal block, max.
Output signal (CLS200 Standard) 2.5 mm²
• Relay output 1 SPDT Form C relay • Degree of protection IP65/Type 4/NEMA 4 (optional
IP68)
- Max. contact voltage • 30 V DC
• Cable inlet 2 x M20x1.5 thread (option: 2 x ½"
• 250 V AC NPT conduit entry including 1
- Max. contact current • 5 A (DC) plugged entry), digital version
has optional PROFIBUS PA con-
• 8 A (AC) nector
- Max. switching capacity 150 W (DC) Power supply (CLS200 Standard) 12 to 250 V AC/DC, 0 to 60 Hz
max. 2 W
2000 VA (AC)
Power supply (CLS200 Digital)
- Time delay (ON and/or OFF) 1 to 60 s
• Bus voltage Standard: 12 to 30 V DC
5 • Solid-state output
- Output Galvanically isolated
Intrinsically Safe: 12 to 24 V DC
• Current consumption 12.5 mA
- Protection Against reversed polarity (bipolar)
Certificates and approvals
- Max. switching voltage • 30 V (DC) (CLS200 Standard)
• 30 V peak (AC) • General Purpose CE, CSA, FM
- Max. load current 82 mA • Dust Ignition Proof (Intrinsically CSA/FM Class II and III, Div. 1,
- Voltage drop < 1 V, typical at 50 mA Safe probe circuit) Groups E, F, G T4

- Time delay (pre or post switch- 1 to 60 s • Dust Ignition Proof (Cable version ATEX II 1/2 D T100 °C
ing) Intrinsically Safe probe)

Output signal (CLS200 Digital) • Explosion Proof (Intrinsically Safe • CSA/FM Class I, Div. 1, Groups
probe circuit) A, B, C, D T4
• Solid-state output (CLS200 Digital) • ATEX II 1/2 G EEx d[ia] IIC T6 to
- Output Galvanically isolated T4
- Protection Against reversed polarity (bipolar) • Marine Lloyds Register of Shipping, Cat-
egories ENV1, ENV2 and ENV5
- Max. switching voltage • 30 V (DC)
• Overfill Protection WHG (Germany)
• 30 V peak (AC)
• Others • SIL/IEC61508 Declaration of
- Max. load current 82 mA Conformity [SIL-2 (overspill)]
- Voltage drop < 1 V, typical at 50 mA • Pattern Approval (China)
- Time delay (ON and/or OFF) Programmable by user • C-TICK (Australia)
(0 to 100 s) Certificates and approvals
• Fail-safe mode Min. or max. (CLS200 Digital)
• Connection Removable terminal block • General Purpose CE, CSA, FM
Rated operating conditions1) • Intrinsically Safe • CSA/FM Class I, II and III, Div. 1,
Groups A, B, C, D, E, F, G T4 or
Installation conditions T63)
• Location Indoor/outdoor • ATEX II 1G 1/2D EEx ia IIC T6 to
T4 T100 °C3)
Ambient conditions
• Explosion Proof/Dust Ignition Proof • CSA/FM Class I, II, and III, Div. 1,
• Ambient temperature -40 to +85 °C (-40 to +185 °F)
(Intrinsically Safe probe circuit) Groups A, B, C, D, E, F, G T4
• Installation category II • ATEX II 1/2G EEx d[ia] IIC T6 to
• Pollution degree 4 T4
• ATEX II 1/2D T100 °C
Medium conditions Liquids, bulk solids, slurries and
interfaces • Non-incendive/Non-sparking • CSA/FM Class I, Div. 2, Groups
A, B, C, D T4 or T6
• Relative dielectric constant εr Min. 1.5
• CSA/FM Class II and III, Div. 2,
• Temperature at process connec- Groups F, G
tion
• ATEX II 3G 2D EEx nA II T6 to T4
- Standard -40 to +85 °C (-40 to +185 °F) T100 °C
- Standard with thermal isolator -40 to +125 °C (-40 to +257 °F) • Marine Lloyds Register of Shipping, Cat-
egories ENV1, ENV2 and ENV5
• Pressure (standard version and -1 to +25 bar g/
versions with extension)2) -14.6 to +365 psi g (nominal) • Others • Pattern Approval (China)
• C-TICK (Australia)

5/16 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200
1) When operation is in areas classified as hazardous, observe restrictions
Communication (CLS200 Digital) • PROFIBUS PA (IEC 61158 CPF3
according to relevant certificate. See also Pressure/Temperature curves on
CP3/2) page 5/24.
• Bus physical layer: IEC 61158-2 2)
Pressure rating of process seal is temperature dependent. See Pres-
MBP (IS) sure/Temperature curves on page 5/24.
3)
• Device profile: PROFIBUS PA Barrier required for Intrinsically Safe protection
profile for Process Control
Devices Version 3.0, Class B
• FISCO field device

Standard version Sanitary version Cable version


Max. length 5.5 m (18 ft) 5.5 m (18 ft) 30 m (98 ft) liquids and slurries 5 m
(16 ft) solids (under loads)
Process R ¾", 1", 1¼", 1½" [(BSPT), EN 1½", 2" sanitary fitting clamp R ¾", 1", 1¼", 1½" [(BSPT), EN
connection 10226/PT (JIS-T), JIS B 0203] 316L stainless steel 10226/PT (JIS-T), JIS B 0203]
¾", 1", 1¼", 1½" NPT [(Taper), ¾", 1", 1¼", 1½" NPT [(Taper),
ANSI/ASME B1.20.1] ANSI/ASME B1.20.1]
G ¾", 1", 1½" [(BSPP), EN ISO G ¾", 1", 1½" [(BSPP),
228-1/PF (JIS-P), JIS B 0202] EN ISO 228-1/PF (JIS-P), JIS B 0202]
316L stainless steel 316L stainless steel
ASME/EN flange ASME/EN flange
Extension material 316L stainless steel 316L stainless steel Fluoroethylene propylene (FEP)
optional PFA coated1) cable with stainless steel core
Sensor wetted parts
O-ring seal material2)
PPS (optional PVDF)
FKM
PPS (optional PVDF)
FKM
PPS (optional PVDF)
FKM
5
Thermal isolator3) Optional Optional Optional
Extension User selected length User selected length Cable extension
1)
PFA coating (7ML5505) has 120 micron thickness
2)
FFKM available as special option. Contact nacc.smpi@siemens.com for
details.
3)
Thermal isolator is used if process connection temperature exceeds
+85 °C (+185 °F).

March 2009 Siemens FI 01 · 2009 US Edition 5/17


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS200, threaded/sanitary version C) 7ML 5 5 0 2 - Pointek CLS200, threaded/sanitary version C) 7 M L 5 5 0 2 -
Versatile inverse frequency shift capacitance level 77 7 77 - 0 777 Versatile inverse frequency shift capacitance level 77 7 77 - 0 777
switch with optional rod/cable choices and config- switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, urable output, ideal for detection of liquids, solids,
slurries, foam and interfaces slurries, foam and interfaces
Note: To select Standard or Digital CLS200 (with Process connection
PROFIBUS PA), see final place holder under ¾" NPT [(Taper), ANSI/ASME B1.20.1] A
Electronics/output. 1" NPT [(Taper), ANSI/ASME B1.20.1] B
Probe version 1½" NPT [(Taper), ANSI/ASME B1.20.1] C
(Threaded lengths include process thread) R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] D
Compact,120 mm (4.72")1) 2) 0X R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E
Extended rod, 250 mm (9.84")1) 2) 1A R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F
Extended rod, 350 mm (13.78")1) 3) 1B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] K
Extended rod, 500 mm (19.69")1) 3) 1C G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), L
Extended rod, 750 mm (29.53")1) 3) 1D JIS B 0202]
Extended rod, 1000 mm (39.37")1) 3) 1E G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] M
Add order code Y01 and plain text: “Insertion
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), N
length ... mm"
JIS B 0202]
- Extended rod, 200 to 999 mm (7.87 to 39.33") 4) 1F
1" sanitary fitting clamp8) 9) R
- Extended rod, 1001 to 2000 mm 1G
1½" sanitary fitting clamp8) 9) S
(39.41 to 78.74")3)
- Extended rod, 2001 to 3000 mm 1H 2" sanitary fitting clamp8) 9) T
(78.78 to 118.11")3) 5) 2½" sanitary fitting clamp8) 9) V
8) 9)
- Extended rod, 3001 to 4000 mm 1J 3" sanitary fitting clamp W

5 (118.15 to 157.48")3) 5)
- Extended rod, 4001 to 5000 mm 1K
Approvals
General Purpose 1
(157.52 to 196.85")3) 5) CSA/FM Class II and III Div. 1, Groups E, F, G T410) 2
10)
- Extended rod, 5001 to 5500 mm 1L FM Class I Div. 1, Groups A, B, C, D T4 3
(196.89 to 216.53")3) 5) CSA Class I, Div. 1, Groups A, B, C, D T410) 4
Extended cable, 3000 mm (118.11"), length adjust- 2A ATEX II 1/2 D T 100 °C 10) 5
10)
able by customer1) 2) ATEX II 1/2 G EEx d [ia] IIC T6 to T4 6
Extended cable, 6000 mm (236.22"), length adjust- 2B CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7
able by customer1) 2) CSA/FM Class II and III, Div. 2, Groups F, G T4 or
Add order code Y01 and plain text: “Insertion 6)
T6; ATEX II 3G 2D EEx nA II T6 to T4 T100 °C
length ... mm" CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8
- Extended cable, 500 to 4999 mm 2C E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
T100 °C 6) 11)
(19.69 to 196.81") 2)
- Extended cable, 5000 to 9999 mm 2D CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0
(196.85 to 393.66") 2) E, F, G T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4
6)
- Extended cable, 10000 to 14999 mm 2E T100 °C
(393.7 to 590.5") 2) Enclosure (see also option A01)
- Extended cable, 15000 to 19999 mm 2F Aluminum epoxy coated
(590.6 to 787.4") 2) • 2 x ½" NPT via adapter, cable inlet, IP65 0
- Extended cable, 20000 to 24999 mm 2G • 2 x M20x1.5 cable inlet, IP65 1
(787.4 to 894.3") 2) • 2 x ½" NPT via adapter, cable inlet, IP68 2
- Extended cable, 25000 to 29999 mm 2H • 2 x M20x1.5 cable inlet, IP68 3
(984.3 to 1181.1") 2)
Additional options
Sanitary compact, 98 mm (3.8")1) 2) 6) 3A Standard version (PPS probe body) A
Add order code Y01 and plain text: “Insertion With thermal isolator (PPS probe body) B
length ... mm" With PVDF probe body C
- Sanitary extended, 110 to 1000 mm 3B With thermal isolator and PVDF probe body D
(4.3 to 39.3")2) 7) With sliding coupling (PPS probe body) E
- Sanitary extended, 1001 to 2000 mm 3C With thermal isolator and sliding coupling F
(39.4 to 78.7")2) 7) With sliding coupling and PVDF probe body G
- Sanitary extended, 2001 to 3000 mm 3D With thermal isolator, sliding coupling and PVDF H
(78.8 to 118.1")2) 5) 7) probe body
- Sanitary extended, 3001 to 4000 mm 3E WHG approval, German overfill protection
(118.1 to 157.5")2) 5) 7) Not required A
- Sanitary extended, 4001 to 5000 mm 3F Required10) B
(157.5 to 196.9")2) 5) 7)
- Sanitary extended, 5001 to 5500 mm 3G Electronics/output
(196.9 to 216.5")2) 5) 7) Standard version without display, 0
12 to 250 V AC/DC, solid-state and relay output12)
Digital version with display, 24 V DC, solid-state 1
output or PROFIBUS PA12) 13)

5/18 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Selection and Ordering data Order No.


Pointek CLS200, threaded/sanitary version C) 7ML 5 5 0 2 -
Versatile inverse frequency shift capacitance level 77 7 77 - 0 777
switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids,
slurries, foam and interfaces
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length Y01
in plain text description
Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
suring-point number/identification (max. 20 charac-
ters); specify in plain text
Electrical connection/cable inlet: PROFIBUS PA A01
connector M126) 14) 15)
Optional enclosure lid: Lid with glass window A04
instead of closed lid without window10) 12)
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
SIL/IEC61508 Declaration of Conformity [SIL-2 C20
(overspill)]10)
Remote Electronics
• Remote mounted electronics with 2 m (79") cable A05
• Remote mounted electronics with 5 m (197") cable
• Mounting bracket (including mounting kit) for re-
A06
A09 5
mote electronics
Instruction manual See page 5/23
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories See page 5/23
1)
No Y01 needed in order code
2)
Available with additional options A to D only
3)
Available with additional options A to H
4) Lengths <350 mm (13.78") available with additional options A to D only
5)
Custom shipping methods required. Contact factory for more details.
6)
Available with electronics option 1 only
7)
Available with process connection R to W only
8)
Available with version 3A to 3G only
9)
Sanitary connection dimensionally corresponds to the applicable ISO 2852
standard
10)
Available with electronics option 0 only
11)
Barrier required for Intrinsically Safe protection
12)
Version with electronics option 0 has a closed lid without window as default;
version with electronics option 1 has a lid with glass window as default.
13) An M12 PROFIBUS PA connector can be selected separately with wildcard
option (A01).
14)
Available with enclosure option 1 only
15)
Available with approval option 1, 7, and 8 only
C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/19


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS200, welded flange C) 7ML 5 5 0 4 - Pointek CLS200, welded flange C) 7 M L 5 5 0 4 -
Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7 Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7
switch with optional rod/cable choices and config- switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, urable output, ideal for detection of liquids, solids,
slurries, foam and interfaces. slurries, foam and interfaces.
Note: To select Standard or Digital CLS200 (with Welded flange, 316L stainless steel, Type A flat
PROFIBUS PA), see final place holder under faced
Electronics/output DN 25, PN 16 J4
Probe version (length from flange face) DN 25, PN 40 J6
Compact, 98 mm (3.86")2) 0X DN 40, PN 16 K4
Extended rod, 250 mm (9.84")2) 1A DN 40, PN 40 K6
Extended rod, 350 mm (13.78")2) 1B DN 50, PN 16 L4
Extended rod, 500 mm (19.69")2) 1C DN 50, PN 40 L6
Extended rod, 750 mm (29.53")2) 1D DN 80, PN 16 M4
Extended rod, 1000 mm (39.37")2) 1E DN 80, PN 401) M6
Add order code Y01 and plain text: “Insertion DN 100, PN 161) N4
length ... mm" DN 100, PN 401) N6
- Extended rod, 200 to 999 mm (7.87 to 39.33") 1F (Note: Flange bolting patterns and facings dimen-
- Extended rod, 1001 to 2000 mm 1G sionally correspond to the applicable ASME B16.5,
(39.41 to 78.74") or EN 1092-1 standard.)
- Extended rod, 2001 to 3000 mm 1H
(78.78 to 118.11")1) Approvals
General Purpose 1
- Extended rod, 3001 to 4000 mm 1J CSA/FM Class II and III Div. 1, Groups E, F, G T43) 2
(118.15 to 157.48")1) FM Class I Div. 1, Groups A, B, C, D T4 3)
3
- Extended rod, 4001 to 5000 mm 1K
CSA Class I, Div. 1, Groups A, B, C, D T43)
5 (157.52 to 196.85")1) 4
- Extended rod, 5001 to 5500 mm 1L ATEX II 1/2 D T100 °C3) 5
(196.89 to 216.53")1) ATEX II 1/2 G EEx d [ia] IIC T6 to T43) 6
Extended cable, 3000 mm (118.1"), length adjust- 2A CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7
able by customer2) CSA/FM Class II and III, Div 2, Groups F, G T4 or
Extended cable, 6000 mm (236.2"), length adjust- 2B T6; ATEX II 3G 2D EEx nA II T6 to T4 T100 °C4)
able by customer2) CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 8
Add order code Y01 and plain text: “Insertion E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
length ... mm" T100 °C4) 5)
- Extended cable, 500 to 4999 mm 2C CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0
(19.69 to 196.81") E, F, G, T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4
- Extended cable, 5000 to 9999 mm 2D T100 °C4)
(196.85 to 393.66") Enclosure (see also option A01)
- Extended cable, 10000 to 14999 mm 2E Aluminum epoxy coated
(393.7 to 590.5") • 2 x ½" NPT via adapter - cable inlet, IP65 0
- Extended cable, 15000 to 19999 mm 2F • 2 x M20x1.5 cable inlet, IP65 1
(590.6 to 787.4") • 2 x ½" NPT via adapter - cable inlet, IP68 2
- Extended cable, 20000 to 24999 mm 2G • 2 x M20x1.5 cable inlet, IP68 3
(787.4 to 894.3")
- Extended cable, 25000 to 29999 mm 2H Additional options
(984.3 to 1181.1") Standard version (PPS probe body) A
With thermal isolator (PPS probe body) B
Process connection
Welded flange, 316L stainless steel, raised face With PVDF probe body C
1" ASME, 150 lb A1 With thermal isolator and PVDF probe body D
1" ASME, 300 lb A2 WHG approval, German overfill protection
1" ASME, 600 lb A3 Not required A
1½" ASME, 150 lb B1 Required3) B
1½" ASME, 300 lb B2 Electronics/output
1½" ASME, 600 lb B3 Standard version without display, 0
2" ASME, 150 lb C1 12 to 250 V AC/DC, solid-state and relay output6)
2" ASME, 300 lb C2 Digital version with display, 24 V DC, solid-state 1
2" ASME, 600 lb C3 output or PROFIBUS PA6) 7)
3" ASME, 150 lb D1
3" ASME, 300 lb1) D2
3" ASME, 600 lb1) D3
4" ASME, 150 lb1) E1
4" ASME, 300 lb1) E2
4" ASME, 600 lb1) E3

5/20 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Selection and Ordering data Order No.


Pointek CLS200, welded flange C) 7ML 5 5 0 4 -
Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7
switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids,
slurries, foam and interfaces.
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total Y01
insertion length in plain text description
Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
suring-point number/identification (max. 20 charac-
ters); specify in plain text
Electrical connection/cable inlet: PROFIBUS PA A01
connector M124) 8) 9)
Optional enclosure lid: Lid with glass window A04
instead of closed lid without window6)
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
SIL/IEC61508 Declaration of Conformity [SIL-2 C20
(overspill)]3)
Remote Electronics
• Remote mounted electronics with 2 m (79") cable A05
• Remote mounted electronics with 5 m (197") cable
5
A06
• Mounting bracket (including mounting kit) for re- A09
mote electronics
Instruction manual See page 5/23
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories See page 5/23
1)
Custom shipping methods required. Contact factory for more details.
2)
No Y01 needed in order code
3)
Available with electronics option 0 only
4) Available with electronics option 1 only
5)
Barrier required for Intrinsically Safe protection
6)
Version with electronics option 0 has a standard closed lid without window
as default; version with electronics option 1 has a standard lid with glass
window as default.
7)
An M12 PROFIBUS PA connector can be selected separately with wildcard
option (A01).
8)
Available with enclosure option 1 only
9)
Available with approval option 1, 7, and 8 only

C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/21


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS200, welded flange, PFA coated C) 7 M L 5 5 0 5 - Pointek CLS200, welded flange, PFA coated C) 7 M L 5 5 0 5 -
Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7 Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7
switch with optional rod/cable choices and config- switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, urable output, ideal for detection of liquids, solids,
slurries, foam and interfaces. slurries, foam and interfaces.
Note: To select Standard or Digital CLS200 (with Approvals
PROFIBUS PA), see final place holder under General Purpose 1
Electronics/output CSA/FM Class II and III Div. 1, Groups E, F, G T43) 2
Probe version (length from flange face) FM Class I Div. 1, Groups A, B, C, D T43) 3
Compact, 98 mm (3.86")1) 0X CSA Class I, Div. 1, Groups A, B, C, D T43) 4
Extended rod, 250 mm (9.84")1) 1A ATEX II 1/2 D T100 °C3) 5
Extended rod, 350 mm (13.78")1) 1B ATEX II 1/2 G EEx d [ia] IIC T6 to T43) 6
Extended rod, 500 mm (19.69")1) 1C CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7
Extended rod, 750 mm (29.53")1) 1D CSA/FM Class II and III, Div 2, Groups F, G; ATEX II
Extended rod, 1000 mm (39.37")1) 1E 3G 2D EEx nA II T6 to T4 T100 °C4)
Add order code Y01 and plain text: “Insertion CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 8
length ... mm" E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
- Extended rod, 200 to 999 mm (7.87 to 39.33") 1F T100 °C4) 5)
- Extended rod, 1001 to 2000 mm 1G CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0
(39.41 to 78.74") E, F, G, T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4
T100 °C4)
- Extended rod, 2001 to 3000 mm 1H
(78.78 to 118.11")2) Enclosure (see also option A01)
- Extended rod, 3001 to 4000 mm 1J Aluminum epoxy coated
(118.15 to 157.48")2) • 2 x ½" NPT via adapter - cable inlet, IP65 0

5 - Extended rod, 4001 to 5000 mm


(157.52 to 196.85")2)
1K • 2 x M20x1.5 cable inlet, IP65
• 2 x ½" NPT via adapter - cable inlet, IP68
1
2
- Extended rod, 5001 to 5500 mm 1L • 2 x M20x1.5 cable inlet, IP68 3
(196.89 to 216.53")2)
Additional options
Process connection Standard version (PPS Probe body) A
Welded flange, 316L stainless steel, raised face, With thermal isolator (PPS Probe body) B
PFA coated
With PVDF probe body C
1" ASME, 150 lb A1
With thermal isolator and PVDF probe body D
1" ASME, 300 lb A2
1" ASME, 600 lb A3 WHG approval, German overfill protection
Not required A
1½" ASME, 150 lb B1
Required3) B
1½" ASME, 300 lb B2
1½" ASME, 600 lb B3 Electronics/output
Standard version without display, 12 to 0
2" ASME, 150 lb C1
250 V AC/DC, solid-state and relay output6)
2" ASME, 300 lb C2
Digital version with display, 24 V DC, solid-state 1
2" ASME, 600 lb C3 output or PROFIBUS PA6) 7)
3" ASME, 150 lb D1 Further designs Order code
3" ASME, 300 lb2) D2
3" ASME, 600 lb2) D3 Total insertion length: enter the total insertion length Y01
in plain text description
4" ASME, 150 lb2) E1 Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
4" ASME, 300 lb2) E2 suring-point number/identification (max. 20 charac-
4" ASME, 600 lb2) E3 ters); specify in plain text
Welded flange, 316L stainless steel, Type A flat
faced, PFA coated Electrical connection/cable inlet: PROFIBUS PA A01
DN 25, PN 16 J4 connector M124) 8) 9)
DN 25, PN 40 J6 Optional enclosure lid: Lid with glass window A04
instead of closed lid without window6)
DN 40, PN 16 K4
Acceptance test certificate: Manufacturer's test C11
DN 40, PN 40 K6
certificate M to DIN 55350, Part 18 and ISO 9000
DN 50, PN 16 L4 Inspection Certificate Type 3.1 per EN 10204 C12
DN 50, PN 40 L6
SIL/IEC61508 Declaration of Conformity [SIL-2 C20
DN 80, PN 16 M4 (overspill)]3)
DN 80, PN 402) M6 Remote Electronics
DN 100, PN 162) N4 • Remote mounted electronics with 2 m (79") cable A05
DN 100, PN 402) N6 • Remote mounted electronics with 5 m (197") cable A06
(Note: Flange bolting patterns and facings dimen- • Mounting bracket (including mounting kit) for re- A09
sionally correspond to the applicable ASME B16.5 mote electronics
or EN 1092-1 standard.)

5/22 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS200, welded flange, PFA coated C) 7 M L 5 5 0 5 -
Instruction manual
Versatile inverse frequency shift capacitance level 7 7 7 77 - 77 7 7 English 7ML1998-5AR02
switch with optional rod/cable choices and config-
urable output, ideal for detection of liquids, solids, French 7ML1998-5AR12
slurries, foam and interfaces. German 7ML1998-5AR32
Note: The instruction manual should be ordered as
Instruction manual See page 5/23 a separate line on the order.
Note: The instruction manual should be ordered as
a separate line on the order. Additional instruction manual
Quick Start manual, multi-language 7ML1998-5QE81
This device is shipped with the Siemens Milltronics Note: Due to ATEX regulations, one Quick Start
manual CD containing the complete ATEX Quick manual is included with every product.
Start and instruction manual library.
This device is shipped with the Siemens Milltronics
Accessories See page 5/23
manual CD containing the complete ATEX Quick
1)
No Y01 needed in order code Start and instruction manual library.
2)
Custom shipping methods required. Contact factory for more details. Accessories
3)
Available with electronics option 0 only Sensguard, ¾" NPT (PPS) 7ML1830-1DL
4) Available with electronics option 1 only
5) Only available for CLS200 with ¾" NPT thread
Barrier required for Intrinsically Safe protection
6) Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM
Version with electronics option 0 has a standard closed lid without window
Only available for CLS200 with ¾" NPT thread
as default; version with electronics option 1 has a standard lid with glass
window as default. ½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA
7)
An M12 PROFIBUS PA connector can be selected separately with wildcard diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 °C
option (A01). (-40 to +212 °F), IP68 (General Purpose)
8)
Available only with enclosure option 1 ½" NPT cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JB
9)
Available with approval option 1, 7, and 8 only and EEx e II, fits cable diameter 6.5 to 14 mm (0.26

C) Subject to export regulations AL: N, ECCN: EAR99


to 0.55"), -60 to +130 °C (-76 to +266 °F), IP68
(Explosion Proof)
5
M20x1.5 cable gland, PA polyamide, ATEX II 2G 7ML1830-1JC
EEx e II, fits cable diameter 7 to 12 mm (0.28 to
0.47"), -20 to +70 °C (-4 to +158 °F), IP68
(General Purpose)
M20x1.5 cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JD
and EEx e II, fits cable diameter 10.5 to 15.9 mm
(0.41 to 0.63"), under armour cable diameter 6.1 to
11.5 mm (0.24 to 0.45"), -60 to +130 °C (-76 to
+266 °F), IP68 (Explosion Proof)
One metallic cable gland M20x1.5, -40 to +80 °C 7ML1930-1AP
(-40 to +176 °F)
One metallic cable gland M20x1.5, -40 to +80 °C 7ML1930-1AQ
(-40 to +176 °F) with integrated shield connection
(available for PROFIBUS PA)
Blind threaded flanges are available. Please
contact nacc.smpi@siemens.com with a com-
pleted application data sheet on page 5/8
Spare parts
Test magnet (digital version) 7ML1830-1JE
Amplifier/power supply, standard version C) 7ML1830-1DJ
Amplifier/power supply, digital version 7ML1830-1JF
LCD display (digital version) 7ML1830-1JK
C) Subject to export regulations AL: N, ECCN: EAR99
F) Subject to export regulations AL: 9I999, ECCN: N

■ Options

Optional Sensguard dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/23


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

■ Characteristic curves

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5502)

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5502)

5/24 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5502)

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5502)

March 2009 Siemens FI 01 · 2009 US Edition 5/25


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5504)

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5504 and 7ML5505)

5/26 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5504)

Pointek CLS200 Process Pressure/Temperature derating curves (7ML5504 and 7ML5505)

March 2009 Siemens FI 01 · 2009 US Edition 5/27


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

■ Dimensional drawings

Pointek CLS200 dimensions - Threaded/Sanitary Process Connections

5/28 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

Pointek CLS200 dimensions - Flanged Process Connections

March 2009 Siemens FI 01 · 2009 US Edition 5/29


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS200

■ Schematics

Pointek CLS200 connections

5/30 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300
The unique modular design of the Pointek CLS300 provides a
■ Overview wide range of configurations, process connections, extensions
and approvals to meet the temperature and pressure require-
ments of specific applications. The modular design makes or-
dering easier and reduces stocking requirements. A wide range
of probe configurations are available, including rod and cable
versions.
• Key Applications: liquids, slurries, bulk solids, relatively high
pressure and temperature, hazardous areas, milling and min-
ing applications

■ Configuration

Pointek CLS300 is an inverse frequency shift capacitance level


switch with optional rod/cable choices and configurable output.
It is ideal for detecting liquids, solids, slurries, foam and inter-
faces in demanding conditions where high pressure and tem-
peratures are present. The digital version (with PROFIBUS PA)
includes a display and provides additional diagnostic features.
5
■ Benefits
• Patented Active-Shield technology so measurement is unaf-
fected by material buildup in active shield section
• Performs in extremely abrasive conditions because of solid
rod construction
• Standard version: 3 LED indicators for adjustment control, out-
put status and power
• Digital version: integral LCD display, and PROFIBUS PA com-
munication
• Push-button calibration, full-function diagnostics
• Multiple output options
• SIL/IEC61508 compliant for use in safety integrated level ap-
plications for overfill protection (SIL-2)

■ Application
The Pointek CLS300 is offered in standard and digital versions.
The standard version has 3 LED indicators with basic relay and
solid-state switch alarms.
The digital version provides an integral LCD display for stand-
alone use, with PROFIBUS PA communication (Profile version
3.0, Class B) when required. Solid-state switch alarm is stan-
dard.
The robust design of CLS300 makes it specifically applicable for
heavy solids applications where abrasive materials occur as in
the mining industry.
The fully potted electronics are unaffected by condensation,
dust or vibration.
Wetted parts are made of stainless steel or stainless steel with a
PFA shield for high chemical resistance. Ceramic inserts are
Pointek CLS300 installation
supplied with high temperature CLS300 devices. Materials with
low or high dielectric constants can be accurately detected. The
unique Active Shield suppresses interference from material
buildup.

March 2009 Siemens FI 01 · 2009 US Edition 5/31


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

■ Technical specifications • Material (enclosure) Powder-coated aluminum with


gasket
(Note: all specifications listed below apply to Standard and Digital ver- • Degree of protection Standard: Type 4/NEMA 4/IP65
sions unless otherwise noted)
Optional: Type 4/NEMA 4/IP68
Mode of operation
• Cable inlet 2 x M20x1.5 thread (option: 2 x ½"
Measuring principle Inverse frequency shift capaci- NPT conduit entry including 1
tive level detection plugged entry), digital version
Input has optional PROFIBUS PA con-
nector
Measured variable Change in picoFarad (pF)
Controls and displays (CLS300 Standard)
Output
• Displays 3 LEDs, for probe status, output
Output signal (CLS300 Standard) status and power supply
• Relay output 1 SPDT Form C relay • Potentiometers 2 potentiometers for time delay
and sensitivity
- Max. contact voltage • 30 V DC
• 250 V AC • Switches 5 DIP switches for delay on/off,
fail-safe high/low, time delay
- Max. contact current • 5 A (DC) test/adjust, high/low sensitivity,
• 8 A (AC) test delay settings
- Max. switching capacity • 150 W (DC) Controls and displays (CLS300 Digital)
• 2000 VA (AC)
• Local display LCD
- Time delay (ON and/or OFF) 1 to 60 s • Configuration • Locally, using 3 button keypad
• Solid-state output (for standalone operation)
• Remotely, using SIMATIC PDM
5 - Output
- Protection
Galvanically isolated
Against reversed polarity (bipolar)
(for installation on a network)
Power supply (CLS300 Standard)
- Max. switching voltage • 30 V (DC) • Supply 12 to 250 V AC/DC, 0 to 60 Hz,
• 30 V peak (AC) galvanically isolated, 2 W
- Max. load current 82 mA Power supply (CLS300 Digital)
- Voltage drop < 1 V, typical at 50 mA • Bus voltage (at process connec- • Standard: 12 to 30 V DC
- Time delay (pre or post switch- 1 to 60 s tion) • Intrinsically Safe: 12 to 24 V DC
ing) • Current consumption 12.5 mA
Output signal (CLS300 Digital) Certificates and approvals (CLS300 Standard)
• Solid-state output (CLS300 Digital) • General Purpose CE, CSA, FM
- Output Galvanically isolated • Dust Ignition Proof (Intrinsically • CSA/FM Class II and III, Div. 1,
- Protection Against reversed polarity (bipolar) Safe probe circuit) Groups E, F, G T4
• ATEX II 1/2D T 100 ºC
- Max. switching voltage • 30 V (DC)
• 30 V peak (AC) • Explosion Proof (Intrinsically Safe • CSA/FM Class I, Div. 1, Groups
probe circuit) A, B, C, D T4
- Max. load current 82 mA • ATEX II 1/2G EEx d [ia] IIC T6 to
- Voltage drop < 1 V, typical at 50 mA T1

- Time delay (ON and/or OFF) Programmable by user (0 to 100s) • Marine Lloyds Register of Shipping, Cat-
egories ENV1, ENV2, and ENV5
• Fail-safe mode Min. or max.
• Overfill Protection WHG (Germany)
• Connection Removable terminal block
• Others • SIL/IEC61508 Declaration of
Accuracy Conformity [SIL-2 (overspill)]
• Pattern Approval (China)
Resolution • C-TICK (Australia)
- Min. sensitivity (pF) 1% change in actual capacitance Certificates and approvals (CLS300 Digital)
- Max. temperature error 0.2% of actual capacitance value • General Purpose CE, CSA, FM
Rated operating conditions1) • Dust Ignition Proof • CSA/FM Class II and III, Div. 1,
Installation conditions Groups E, F, G T4 or T6 ATEX II
1/2D 2D T100 °C3)
Location Indoor/outdoor
• Explosion Proof/Dust Ignition Proof • CSA/FM Class I, II and III, Div. 1,
Ambient conditions (Intrinsically Safe probe circuit) Groups A, B, C, D, E, F, G T4 or
• Ambient temperature -40 to +85 °C (-40 to +185 °F) T6
• ATEX II 1/2GD EEx d [ia] IIC T6
• Pressure range2) -1 to +35 bar g to T4 T100 °C
(-14.6 to +511 psi g)
• Intrinsically Safe • CSA/FM Class I, II and III, Div. 1,
Medium conditions Liquids, bulk solids, slurries and Groups A, B, C, D, E, F, G T4 or
interfaces, and applications with T63)
viscous materials • ATEX II 1G 1/2D EEx ia IIC T6 to
T4 T100 °C3)
• Relative dielectric constant εr Min. 1.5
• Marine Lloyds Register of Shipping, Cat-
• Temperature egories ENV1, ENV2, and ENV5
- Standard version -40 to +200 °C (-40 to +392 °F) • Others • Pattern Approval (China)
- High-temperature version -40 to +400 °C (-40 to +752 °F) • C-TICK (Australia)
Design

5/32 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300
Communication (CLS300 Digital) • PROFIBUS PA (IEC 61158 CPF3
CP3/2)
• Bus physical layer: IEC 61158-2
MBP-(IS)
• Device profile: PROFIBUS PA
profile for Process Control De-
vices Version 3.0, Class B
• FISCO field device
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate. See also Pressure/Temperature curves
starting on page 5/41.
2)
Pressure rating of process seal is temperature dependent. See Pres-
sure/Temperature curves starting on page 5/41.
3) Barrier required for Intrinsically Safe protection

Design: Probe
Standard version High Temperature version Cable version
Length Min. 350 mm (14"), Min. 350 mm (14"), Min. 1000 mm (40"),
max. 1000 mm (40") max. 1000 mm (40") max. 25000 mm (984")
Sensor wetted parts PFA (no insulation on active probe), Ceramic (no insulation on active 316 stainless steel, optional PFA
316L stainless steel probe), 316L stainless steel
O-ring seal material FKM1) Graphite FKM1)
Thermal isolator
Extension
Optional
User selectable length
Standard
User selectable length
Optional
User selectable cable length
5
1) FFKM available as special option. Contact nacc.smpi@siemens.com for details.

March 2009 Siemens FI 01 · 2009 US Edition 5/33


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS300, threaded version D) 7 M L 5 5 1 0 - Pointek CLS300, threaded version D) 7 M L 5 5 1 0 -
Inverse frequency shift capacitance level switch 7 7 7 77 - 77 A 7 Inverse frequency shift capacitance level switch 7 7 7 77 - 77 A 7
with optional rod/cable choices and configurable with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur- output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present. where high pressure and temperatures are present.
Note: To select Standard or Digital CLS300 (with Approvals
PROFIBUS PA), see final place holder under General Purpose 1
Electronics/output CSA/FM Class II and III Div. 1, Groups E, F, G T45) 2
Probe version CSA/FM Class I Div. 1, Groups A, B, C, D T45) 3
(Threaded lengths include process thread) ATEX II 1/2 D T 100 °C 5) 4
Standard version, rod 350 mm (13.78")1) 0X ATEX II 1/2 G EEx d [ia] IIC T6 to T15) 5
Extended rod, length 500 mm (19.69")1) 1A
CSA/FM Class II and III, Div 1, Groups E, F, G 6
Extended rod, length 750 mm (29.53")1) 1B T4 or T6;6)
Extended rod, length 1000 mm (39.37")1) 1C ATEX II 1/2D 2D T100 °C7)
Add order code Y01 and plain text: “Insertion CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 7
length ... mm" E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
- Extended rod, factory adjusted length 250 to 1D T100 °C6) 7)
999 mm (9.8 to 39.3") CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8
E, F, G T4; ATEX II 1/2GD EEx d [ia] IIC T6 to T4
Extended cable, length 3000 mm (118.1"), length 2A T100 °C7)
adjustable by customer1) 2)
Extended cable, length 6000 mm (236.2"), length 2B WHG approval, German overfill protection
adjustable by customer1) 2) Not required 0

5 Add order code Y01 and plain text: “Insertion


length ... mm"
Required 5)
Enclosure (see also option A01)
1

- Extended cable, factory adjusted length 1000 to Aluminum epoxy coated


2C
4999 mm (39.4 to 196.8")2) • 2 x ½" NPT via adapter, cable inlet, IP65 1
- Extended cable, factory adjusted length 5000 to 2D • 2 x M20x1.5 cable inlet, IP65 2
9999 mm (196.9 to 393.7")2)
• 2 x ½" NPT via adapter, cable inlet, IP68 3
- Extended cable, factory adjusted length 10000 2E • 2 x M20x1.5 cable inlet, IP68 4
to 14999 mm (393.7 to 590.5")2)
Additional options
- Extended cable, factory adjusted length 15000 2F
to 19999 mm (590.6 to 787.4")2) Standard version A
- Extended cable, factory adjusted length 20000 2G With thermal isolator [for process connection tem- B
to 25000 mm (787.4 to 984.3")2) perature over +85 °C (+185 °F)]
- Extended PFA cable, length 3000 mm (118.1"), 3A Electronics/output
length adjustable by customer1) 3) Standard version without display, 0
- Extended PFA cable, length 6000 mm (236.2"), 3B 12 to 250 V AC/DC, solid-state and relay output
length adjustable by customer1) 3) Digital version with display, 24 V DC, solid-state 1
- Extended PFA cable, length 1000 to 4999 mm 3C output or PROFIBUS PA8)
(39.4 to 196.8")2) 3) Further designs Order code
- Extended PFA cable, length 5000 to 9999 mm 3D
Please add “-Z" to Order No. and specify Order
(196.9 to 393.7")2) 3)
code(s).
- Extended PFA cable, length 10000 to 14999 mm 3E
Total insertion length: enter the total insertion length Y01
(393.7 to 590.5")2) 3)
in plain text description
- Extended PFA cable, length 15000 to 19999 mm 3F Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
(590.6 to 787.4")2) 3)
suring-point number/identification (max. 20 charac-
- Extended PFA cable, length 20000 to 25000 mm 3G ters); specify in plain text
(787.4 to 984.3")2) 3)
Electrical connection/cable inlet: PROFIBUS PA A01
Note: Verify that shield length selected in A07
connector M127) 9) 10)
and A08 is appropriate for the version selected.
Optional enclosure lid: Lid with glass window A04
Process connection
instead of closed lid without window11)
¾" NPT [(Taper), ANSI/ASME B1.20.1]4) A
1" NPT [(Taper), ANSI/ASME B1.20.1]4) B Acceptance test certificate: Manufacturer's test C11
1½" NPT [(Taper), ANSI/ASME B1.20.1] C certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]4) D
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]4) E SIL/IEC61508 Declaration of Conformity [SIL-2 C20
(overspill)]5)
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F
Extended Active Shield (Y02) (standard length is
1¼" NPT [(Taper), ANSI/ASME B1.20.1] K
125 mm, including threaded process connection
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), L length)12)
JIS B 0202]4) • Active Shield length (Y02): 250 mm (min. insertion A07
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), M length: rod, 475 mm, cable, 1000 mm)
JIS B 0202]4) • Active Shield length (Y02): 400 mm (min. insertion A08
length: rod, 625 mm, cable, 1000 mm)
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), N
JIS B 0202]

5/34 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Selection and Ordering data Order No.


Pointek CLS300, threaded version D) 7 M L 5 5 1 0 -
Inverse frequency shift capacitance level switch 7 7 7 77 - 77 A 7
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present.
Instruction manual See page 5/40
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories See page 5/40
1)
No Y01 needed in order code
2)
Available with process connection C, F, N only
3)
Do not select PFA cable version if process temperature exceeds +200 °C
(+392 °F).
4)
Available with Probe versions 0X, 1A to 1D only
5)
Available with electronics option 0 only
6)
Barrier required for Intrinsically Safe protection
7) Available with electronics option 1 only
8)
An M12 PROFIBUS PA connector can be selected separately with wildcard
option A01.

5
9)
Available with enclosure option 2 only
10)
Available with approval option 1, 6, and 7 only
11)
Version with electronics option 0 has a standard closed lid without window
as default; version with electronics option 1 has a standard lid with glass
window as default.
12)
See dimension drawings on page 5/44 for further explanation of Y02.

D) Subject to export regulations AL: N, ECCN: EAR99H

March 2009 Siemens FI 01 · 2009 US Edition 5/35


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS300, welded flange C) 7ML 5 5 0 6 - Pointek CLS300, welded flange C) 7ML 5 5 0 6 -
Inverse frequency shift capacitance level switch 7 7 7 77 - 77 7 7 Inverse frequency shift capacitance level switch 7 7 7 77 - 77 7 7
with optional rod/cable choices and configurable with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur- output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present. where high pressure and temperatures are present.
Note: To select Standard or Digital CLS300 (with Welded flange, 316L stainless steel, Type A flat
PROFIBUS PA), see final place holder under faced
Electronics/output DN 25, PN 163) J4
Probe version (length from flange face) DN 25, PN 403) J6
Standard version, rod 350 mm (13.78")1) 0X DN 40, PN 16 K4
Extended rod, length 500 mm (19.69")1) 1A DN 40, PN 40 K6
Extended rod, length 750 mm (29.53")1) 1B DN 50, PN 16 L4
Extended rod, length 1000 mm (39.37")1) 1C DN 50, PN 40 L6
Add order code Y01 and plain text: “Insertion DN 80, PN 16 M4
length ... mm" DN 80, PN 404) M6
- Extended rod, length 250 to 999 mm (9.8 to 1D DN 100, PN 164) N4
39.3") DN 100, PN 404) N6
Extended cable, length 3000 mm (118.1"), length 2A Note: Flange bolting patterns and facings dimen-
adjustable by customer1) sionally correspond to the applicable ASME B16.5,
Extended cable, length 6000 mm (236.2"), length 2B EN 1092-1 standard, or JIS B 2238 standard.
adjustable by customer1) Approvals
Add order code Y01 and plain text: “Insertion General Purpose 1
length ... mm" CSA/FM Class II and III Div. 1, Groups E, F, G T45) 2
- Extended cable, length 1000 to 4999 mm CSA/FM Class I Div. 1, Groups A, B, C, D T45) 3
5
2C
(39.4 to 196.8") ATEX II 1/2 D T100 °C5) 4
- Extended cable, length 5000 to 9999 mm 2D ATEX II 1/2 G EEx d [ia] IIC T6 to T15) 5
(196.9 to 393.7") CSA/FM Class II and III, Div 1, Groups E, F, G T4 or 6
- Extended cable, length 10000 to 14999 mm 2E T6; ATEX II 1/2D 2D T100 °C6) 7)
(393.7 to 590.5")
CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 7
- Extended cable, length 15000 to 19999 mm 2F E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4
(590.6 to 787.4") T100 °C5) 6)
- Extended cable, length 20000 to 25000 mm 2G CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8
(787.4 to 984.3") E, F, G T4; ATEX II 1/2GD EEx d [ia] IIC T6 to T4
Extended PFA cable, length 3000 mm (118.1"), 3A T100 °C6)
length adjustable by customer1) 2) WHG approval, German overfill protection
Extended PFA cable, length 6000 mm (236.2"), 3B Not required 0
length adjustable by customer1) 2) Required 5) 1
Add order code Y01 and plain text: “Insertion Additional options
length ... mm" Standard version A
- Extended PFA cable, length 1000 to 4999 mm 3C With thermal isolator [for process connection tem- B
(39.4 to 196.8")2) perature over +85 °C (+185 °F)]
- Extended PFA cable, length 5000 to 9999 mm 3D Enclosure (see also option A01)
(196.9 to 393.7")2) Aluminum epoxy coated
- Extended PFA cable, length 10000 to 14999 mm 3E • 2 x ½" NPT via adapter, cable inlet, IP65 A
(393.7 to 590.5")2) • 2 x M20x1.5 cable inlet, IP65 B
- Extended PFA cable, length 15000 to 19999 mm 3F • 2 x ½" NPT via adapter, cable inlet, IP68 C
(590.6 to 787.4")2) • 2 x M20x1.5 cable inlet, IP68 D
- Extended PFA cable, length 20000 to 25000 mm 3G
(787.4 to 984.3")2) Electronics/output
Standard version without display, 0
Process connection 12 to 250 V AC/DC, solid-state and relay output
Welded flange, 316L stainless steel, raised face Digital version with display, 24 V DC, solid-state 1
1" ASME, 150 lb3) A1 output or PROFIBUS PA8)
1" ASME, 300 lb3) A2 Further designs Order code
1" ASME, 600 lb3) 4) A3 Please add “-Z" to Order No. and specify Order
1½" ASME, 150 lb B1 code(s).
1½" ASME, 300 lb B2 Total insertion length: enter the total insertion length Y01
1½" ASME, 600 lb3) B3 in plain text description
2" ASME, 150 lb C1 Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
2" ASME, 300 lb C2 suring-point number/identification (max. 20 charac-
2" ASME, 600 lb3) C3 ters); specify in plain text
3" ASME, 150 lb D1 Electrical connection/cable inlet: PROFIBUS PA A01
3" ASME, 300 lb3) D2 connector M126) 9) 10)
3" ASME, 600 lb3) D3 Optional enclosure lid: Lid with glass window A04
instead of closed lid without window11)
4" ASME, 150 lb3) E1
4" ASME, 300 lb3) E2 Acceptance test certificate: Manufacturer's test C11
4" ASME, 600 lb3) E3 certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
SIL/IEC61508 Declaration of Conformity [SIL-2 C20
(overspill)]5)
Extended Active Shield (Y02) (standard length is
105 mm)12)
• Active Shield length (Y02): 230 mm (min. insertion A07
length: rod, 475 mm, cable, 1000 mm)
• Active Shield length (Y02): 380 mm (min. insertion A08
length: rod, 625 mm, cable, 1000 mm)

5/36 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Selection and Ordering data Order No.


Pointek CLS300, welded flange C) 7ML 5 5 0 6 -
Inverse frequency shift capacitance level switch 7 7 7 77 - 77 7 7
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present.
Instruction manual See page 5/40
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories See page 5/40
1)
No Y01 needed with order code
2)
Do not select PFA cable version if process temperature exceeds +200 °C
(+392 °F).
3)
Available with Probe versions 0X, 1A to 1D only
4) Custom shipping methods required. Contact factory for more details
5) Available with electronics option 0 only
6)
Barrier required for Intrinsically Safe protection
7)
Available with electronics option 1 only
8)
An M12 PROFIBUS PA connector can be selected separately with wildcard
option A01.
9)
Available with enclosure option B only

5
10)
Available with approval option 1, 6, and 7 only
11)
Version with electronics option 0 has a standard closed lid without window
as default; version with electronics option 1 has a standard lid with glass
window as default.
12)
See dimension drawings on page 5/44 for further explanation of Y02.

C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/37


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS300, high temperature, threaded C) 7 M L 5 5 0 7 - Pointek CLS300, high temperature, threaded C) 7 M L 5 5 0 7 -
Inverse frequency shift capacitance level switch 7 7 7 77 - 77 A 7 Inverse frequency shift capacitance level switch 7 7 7 77 - 77 A 7
with optional rod/cable choices and configurable with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur- output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present. where high pressure and temperatures are present.
Note: To select Standard or Digital CLS300 (with Electronics/output
PROFIBUS PA), see final place holder under Standard version without display, 0
Electronics/output 12 to 250 V AC/DC, solid-state and relay output
Version Digital version with display, 24 V DC, solid-state 1
(Threaded lengths include process thread) output or PROFIBUS PA7)
Standard version, rod 350 mm (13.78")1) 0X Further designs Order code
Extended rod, length 500 mm (19.69")1) 1A
Please add “-Z" to Order No. and specify Order
Extended rod, length 750 mm (29.53")1) 1B code(s).
Extended rod, length 1000 mm (39.37")1) 1C Total insertion length: enter the total insertion length Y01
Add order code Y01 and plain text: “Insertion in plain text description
length ... mm" Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Y15
Extended rod, customer specified length [min. 1D Measuring-point number/identification (max. 20
250 mm (9.8") length, max. 999 mm (39.3") length] characters); specify in plain text
Note: Verify that shield length selected in A07 or Electrical connection/cable inlet: PROFIBUS PA A01
A08 is appropriate for the version selected. connector M124) 8) 9)

5 Process connection
316L stainless steel
Optional enclosure lid: Lid with glass window
instead of closed lid without window8)
A04

¾" NPT [(Taper), ANSI/ASME B1.20.1] A Acceptance test certificate: Manufacturer's test C11
1" NPT [(Taper), ANSI/ASME B1.20.1] B certificate M to DIN 55350, Part 18 and ISO 9000
1½" NPT [(Taper), ANSI/ASME B1.20.1] C Inspection Certificate Type 3.1 per EN 10204 C12

R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] D SIL/IEC61508 Declaration of Conformity [SIL-2 C20
(overspill)]2)
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F Extended Active Shield (Y02) [standard length is
125 mm (4.92"), not including threaded process
1¼" NPT [(Taper), ANSI/ASME B1.20.1] K connection length]9)
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] L • Active Shield length (Y02): 250 mm (9.84"), [min. A07
insertion length: rod 475 mm (18.70"), cable
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] M 1000 mm (39.37")]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), N • Active Shield length (Y02): 400 mm (15.75"). [min. A08
JIS B 0202] insertion length: rod 625 mm (24.61"), cable
Approvals 1000 mm (39.37")]
General Purpose 1 Instruction manual See page 5/40
CSA/FM Class II and III Div. 1, Groups E, F, G T42) 2 Note: The instruction manual should be ordered as
CSA/FM Class I Div. 1, Groups A, B, C, D T42) 3 a separate line on the order.

ATEX II 1/2 D T100 °C2) 4 This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
ATEX II 1/2 G EEx d [ia] IIC T6 to T12) 5 Start and instruction manual library.
CSA/FM Class II and III, Div 1, Groups E, F, G T4 or 6
T6; ATEX II 1/2D 2D T100 °C3) 4) Accessories See page 5/40
1)
CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 7 No Y01 needed with order code
E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 2)
Available with electronics option 0 only
T100 °C5) 6) 3) Barrier required for Intrinsically Safe protection
4)
CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8 Available with electronics option 1 only
5)
E, F, G T4; ATEX II 1/2GD EEx d [ia] IIC T6 to T4 An M12 PROFIBUS PA connector can be selected separately with wildcard
T100 °C4) option A01.
6)
Available with enclosure option 1 only
WHG approval, German overfill protection 7)
Available with approval option 1, 6, and 7 only
8)
Not required 0 Version with electronics option 0 has a standard closed lid without window
Required 2) 1 as default; version with electronics option 1 has a standard lid with glass
window as default.
9)
Enclosure (see also option A01) See dimension drawings on page 5/44 for further explanation of Y02
Aluminum epoxy coated
C) Subject to export regulations AL: N, ECCN: EAR99
• 2 x ½" NPT via adapter, cable inlet, IP65 0
• 2 x M20x1.5 cable inlet, IP65 1
• 2 x ½" NPT via adapter, cable inlet, IP68 2
• 2 x M20x1.5 cable inlet, IP68 3
Additional options
With thermal isolator B

5/38 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS300, high temperature, welded C) 7 M L 5 5 0 8 - Pointek CLS300, high temperature, welded C) 7 M L 5 5 0 8 -
flange 7 7 7 77 - 77 7 7
flange 7 7 7 77 - 77 7 7
Inverse frequency shift capacitance level switch Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slur- output. It is ideal for detecting liquids, solids, slur-
ries, foam and interfaces in demanding conditions ries, foam and interfaces in demanding conditions
where high pressure and temperatures are present. where high pressure and temperatures are present.
Note: To select Standard or Digital CLS300 (with WHG approval, German overfill protection
PROFIBUS PA), see final place holder under Not required 0
Electronics/output Required 3) 1
Version (length from flange face) Additional options
Standard version, rod 350 mm (13.78")1) 0X With thermal isolator [for process temperature over B
Extended rod, length 500 mm (19.69")1) 1A +85 °C (+185 °F)]
Extended rod, length 750 mm (29.53")1) 1B
Enclosure (see also option A01)
Extended rod, length 1000 mm (39.37")1) 1C Aluminum epoxy coated
Add order code Y01 and plain text: “Insertion • 2 x ½" NPT via adapter, cable inlet, IP65 A
length ... mm" • 2 x M20x1.5 cable inlet, IP65 B
Extended rod, customer specified length [min. 1D • 2 x ½" NPT via adapter, cable inlet, IP68 C
250 mm (9.8") length, max. 999 mm (39.3") length] • 2 x M20x1.5 cable inlet, IP68 D
Note: Verify that shield length selected in A07 and
A08 is appropriate for the version selected. Electronics/output
Standard version without display, 0
Process connection
12 to 250 V AC/DC, solid-state and relay output
Welded flange, 316L stainless steel, raised face Digital version with display, 24 V DC, solid-state
5
1
1" ASME, 150 lb A1 output or PROFIBUS PA6)
1" ASME, 300 lb A2 Further designs Order code
1" ASME, 600 lb2) A3
Please add “-Z" to Order No. and specify Order
1½" ASME, 150 lb B1 code(s).
1½" ASME, 300 lb B2
Total insertion length: enter the total insertion length Y01
1½" ASME, 600 lb2) B3
in plain text description
2" ASME, 150 lb C1 Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
2" ASME, 300 lb C2 suring-point number/identification (max. 20 charac-
2" ASME, 600 lb2) C3 ters); specify in plain text
3" ASME, 150 lb D1 Electrical connection/cable inlet: PROFIBUS PA A01
3" ASME, 300 lb2) D2 connector M125) 7) 8)
3" ASME, 600 lb2) D3 Optional enclosure lid: Lid with glass window A04
instead of closed lid without window9)
4" ASME, 150 lb2) E1
4" ASME, 300 lb 2)
E2 Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000
4" ASME, 600 lb2) E3
Inspection Certificate Type 3.1 per EN 10204 C12
Welded flange, 316L stainless steel, Type A flat
faced SIL/IEC61508 Declaration of Conformity [SIL-2 C20
(overspill)]3)
DN 25, PN 16 J4
DN 25, PN 40 J6 Extended Active Shield (Y02) [standard length is
105 mm (4.13")]10)
DN 40, PN 16 K4
• Active Shield length (Y02): 230 mm (9.06“) [min. A07
DN 40, PN 40 K6 insertion length: rod 475 mm (18.70“), cable
DN 50, PN 16 L4 1000 mm (39.37“)]
DN 50, PN 40 L6 • Active Shield length (Y02): 380 mm (14.96“) [min. A08
insertion length: rod 625 mm (24.61“), cable
DN 80, PN 16 M4 1000 mm (39.37“)]
DN 80, PN 402) M6
Instruction manual See page 5/40
DN 100, PN 162) N4
Note: The instruction manual should be ordered as
DN 100, PN 402) N6
a separate line on the order.
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5 This device is shipped with the Siemens Milltronics
or EN 1092-1 standard.) manual CD containing the complete ATEX Quick
Start and instruction manual library.
Approvals
General Purpose 1 Accessories See page 5/40
CSA/FM Class II and III Div. 1, Groups E, F, G T43) 2 1)
No Y01 needed with order code
CSA/FM Class I Div. 1, Groups A, B, C, D T43) 3 2)
Custom shipping methods required. Contact factory for more details
ATEX II 1/2 D T100 °C3) 4 3)
Available with electronics option 0 only
ATEX II 1/2 G EEx d [ia] IIC T6 to T13) 5 4) Barrier required for Intrinsically Safe protection
5) Available with electronics option 1 only
CSA/FM Class II and III, Div 1, Groups E, F, G T4 or 6
T6; ATEX II 1/2D 2D T100 °C4) 5) 6)
An M12 PROFIBUS PA connector can be selected separately with wildcard
option (A01).
CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 7 7)
Available with enclosure option B only
E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 8)
T100 °C4) 5) Available with approval option 1, 6, and 7 only
9)
Version with electronics option 0 has a standard closed lid without window
CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8 as default; version with electronics option 1 has a standard lid with glass
E, F, G T4; ATEX II 1/2GD EEx d [ia] IIC T6 to T4 window as default.
T100 °C5) 10)
See dimension drawings on page 5/44 for further explanation of Y02

March 2009 Siemens FI 01 · 2009 US Edition 5/39


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Selection and Ordering data Order No.


Instruction manual
English 7ML1998-5CK04
German 7ML1998-5CK34
French 7ML1998-5CK14
Note: The instruction manual should be ordered as
a separate line on the order.
Quick Start manual, multi-language C) 7ML1998-5QF81
Note: Due to ATEX regulations, one Quick Start
manual is included with every product.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
½" NPT cable gland, nickel plated brass, fits cable F) 7ML1830-1JA
diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 °C
(-40 to +212 °F), IP68 (General Purpose)
½" NPT cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JB
and EEx e II, fits cable diameter 6.5 to 14 mm
(0.26 to 0.55"), -60 to +130 °C (-76 to +266 °F),
IP68 (Explosion Proof)
M20x1.5 cable gland, PA polyamide, ATEX II 2G F) 7ML1830-1JC
EEx e II, fits cable diameter 7 to 12 mm (0.28 to

5 0.47"), -20 to +70 °C (-4 to +158 °F), IP68


(General Purpose)
M20x1.5 cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JD
and EEx e II, fits cable diameter 10.5 to 15.9 mm
(0.41 to 0.63"), under armour cable diameter 6.1 to
11.5 mm (0.24 to 0.45"), -60 to +130 °C (-76 to
+266 °F), IP68 (Explosion Proof)
One metallic cable gland M20x1.5, -40 to +80 °C C) 7ML1930-1AP
(-40 to +176 °F)
One metallic cable gland M20x1.5, -40 to +80 °C C) 7ML1930-1AQ
(-40 to +176 °F) with integrated shield connection
(available for PROFIBUS PA)
Blind threaded flanges are available. Please
contact nacc.smpi@siemens.com with a com-
pleted application data sheet found on page 5/8
Spare parts
Test magnet (digital version) C) 7ML1830-1JE
Amplifier/power supply, standard version C) 7ML1830-1DJ
Amplifier/power supply, digital version C) 7ML1830-1JF

LCD display (digital version) C) 7ML1830-1JK

C) Subject to export regulations AL: N, ECCN:EAR99


F) Subject to export regulations AL: 9I999, ECCN: N

5/40 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

■ Characteristic curves

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5510)

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5507)

March 2009 Siemens FI 01 · 2009 US Edition 5/41


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5506)

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5508)

5/42 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5506)

Pointek CLS300 Process Pressure/Temperature derating curves (7ML5508)

March 2009 Siemens FI 01 · 2009 US Edition 5/43


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

■ Dimensional drawings

Pointek CLS300 dimensions - Threaded Process Connections

5/44 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

Pointek CLS300 dimensions - Flanged Process Connections

March 2009 Siemens FI 01 · 2009 US Edition 5/45


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS300

■ Schematics

Pointek CLS300 connections

5/46 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

■ Overview ■ Configuration

5
Pointek CLS500 is an inverse frequency shift capacitance level
switch for detecting interfaces, solids, liquids, toxic and aggres-
sive chemicals in critical conditions of high temperature and
pressure.

■ Benefits
• Patented Active-Shield technology so measurement is unaf-
fected by material buildup in active shield section
• 2-wire loop powered with solid-state switch or 4 to 20/20 to
4 mA output
• Simple push-button calibration and integrated local display
• Full function diagnostics
• HART communications for remote commissioning and inspec-
tion

■ Application
Patented Active-Shield technology ensures that measurement is
unaffected by vapours, product deposits, dust and condensa-
tion. The unique mechanical probe design coupled with a high
performance transmitter gives superior performance in a wide
range of level detection applications.
Pointek CLS500’s microprocessor-based electronics provide
Pointek CLS500 installation
one-point calibration, making setup possible without shutting
down your production process.
• Key Applications: foam or liquid/foam level, glycol regenera-
tors, high-pressure coalescers, LNG applications

March 2009 Siemens FI 01 · 2009 US Edition 5/47


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

■ Technical specifications Design


Material
Input
• Wetted parts material
Measuring range 0 to 330 pF
- Standard rod 316L stainless steel
Span Min. 1 pF
• Probe isolation (rod) PFA, enamel
Output
Probe diameter
Solid-state switch
• Standard rod version (PFA) 16 mm (0.63")
- Output Galvanically isolated
• High temperature rod version 16 mm (0.63")
- Protection Against reversed polarity (bipolar) (Enamel)
- Max. switching voltage • 30 V (DC) • High temperature rod version 19 mm (0.75")
• 30 V peak (AC) (Stainless steel)
- Max. load current 82 mA Probe length
- Voltage drop < 1 V, typical at 50 mA • Standard rod version (PFA) Max. 1000 mm (39.4") with 16 mm
(0.63") diameter probe
- Time delay 1 to 60 s
(pre or post switching) • High temperature rod version Max. measuring length 1000 mm
(Enamel) (39.4") with 16 mm (0.63") diame-
Current loop 4 to 20 mA/20 to 4 mA ter probe
Accuracy (transmitter) • High temperature rod version Max. measuring length 1000 mm
Temperature stability 0.15 pF (0 pF) or < 0.25% (typical (Stainless steel) (39.4") with 19 mm (0.75") diame-
< 0.1%) of actual measurement ter probe
value, whichever is greater over Process connection of probe
5 Non-linearity and repeatability
the full temperature range
0.1% of full scale and actual mea-
• Threaded mounting NPT [(Taper), ANSI/ASME
B1.20.1]
surement respectively
R [(BSPT), EN 10226/PT (JIS-T),
Accuracy Deviation < 0.1% of measured JIS B 0203]
value
G [(BSPP), EN ISO 228-1/PF
Rated operating conditions 1) (JIS-P), JIS B 0202]
Installation conditions • Flange mounting ASME, EN 1092-1
- Location Indoor/outdoor Enclosure
Ambient conditions • Material Aluminium, epoxy-coated (Stain-
less steel option available. Con-
• Ambient temperature (transmitter) -40 to +85 °C (-40 to +185°F) tact nacc.smpi@siemens.com)
• Installation category I • Cable inlet 2 x ½" NPT
• Pollution degree 4 • Degree of protection Type 4X/NEMA4X/IP65, IP68
Medium conditions Power supply Max. 33 V DC
• Relative dielectric constant εr Min. 1.5 Features
• Process temperature (probe) Temperature ratings are pressure Measurement current signalling NAMUR NE 43
dependent. See Pressure/Tem-
perature curves on page 5/53. Safety • Inputs/outputs fully galvanically
isolated
- Standard (PFA) -50 to +200 °C (-58 to +392 °F)
• Polarity-insensitive current loop
- High temperature stainless steel -60 to +400 °C (-76 to +752 °F)
version with enamel insulation • Fully potted
and thermal isolator • Integrated safety barrier
- High temperature stainless steel -60 to +400 °C (-76 to +752 °F) • Diagnostics with fault alarm when: Primary variable (PV) out of limits,
version with thermal isolator system failure in measurement
circuit, deviation between A/D
Pressure range Pressure rating of process seal is and D/A converter, check sum,
temperature dependent. watch dog and self-checking
See Pressure/Temperature curves facility
on page 5/53.
• Function rotary switch Positions 0 to 9, A to F
• Standard (PFA) -1 to +150 bar g
(-14.6 to +2175 psi g) • SMART communication Conforming to HART Communi-
cation Foundation (HCF)
• High temperature version (Enam- -1 to +345 bar g
el) (-14.6 to +5004 psi g)
• High temperature version (Stain- Pressure rating of process seal is
less steel) temperature dependent.
See Pressure/Temperature curves
on page 5/53.

5/48 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500
Certificates and approvals
• General Purpose CE (complies with E.C.C. require-
ments of EN 55011 and
EN 61326)
• Non incendive/Non sparking • CSA/FM Class I, Div. 2, Groups
A, B, C, D T4
• ATEX II 3G 2D EEx n A [ib] IIC T6
to T4 T100 °C
• Dust Ignition Proof • CSA/FM Class II and III, Div. 1,
Groups E, F, G T4
• ATEX II 1/2 GD EEx d [ia] T6 to
T1 T100 °C
• Explosion Proof • FM Class 1, Div. 1, Groups A, B,
C, D T4
• ATEX II 1/2 GD EEx d [ia] IIC T6
to T1 T100 °C
• Marine Lloyds Register of Shipping, Cat-
egories ENV1, ENV2, ENV3,
ENV5
• Pressure PED 97/23/EC, CSA B51
• Other C-TICK (Australia)
1) When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate. See also Pressure/Temperature curves on
page 5/53. 5
Standard Combinations
Pointek CLS500 Standard HT Series
probe version
Process connection Standard (PFA) High Temperature
types (7ML5601, 7ML5602, (Enamel or Stainless
7ML5603) steel) (7ML5604)
Threaded Available as standard -
Flange Available as standard Available as standard
Process connection
materials
316L stainless steel Available as standard Available as standard
Probe insulation
None - HT Stainless: avail-
able as standard
PFA Available as standard –
Enamel HT Enamel: available
as standard
Length parameters
Max. rod length 1000 mm (40") 1000 mm (40")
Process
condtitions1)
Max. pressure 150 bar g (2175 psi g) Stainless steel:2)
35 bar g (507 psi g)
Enamel:2) 345 bar g
(5004 psi g)
Max. temperature +200 °C (+392 °F) +400 °C (+752 °F)
1) When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate. See also Pressure/Temperature curves on
page 5/53.
2) Pressure rating of process seal is temperature dependent. See Pres-
sure/Temperature curves on page 5/53.
– Not available as standard

March 2009 Siemens FI 01 · 2009 US Edition 5/49


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS500, threaded C) 7 M L 5 6 0 1 - Pointek CLS500, welded flange C) 7 M L 5 6 0 2 -
Inverse frequency shift capacitance level switch for 7 7 7 77 - 77 A 0 Inverse frequency shift capacitance level switch for 7 7 7 77 - 77 A 0
detecting interfaces, solids, liquids, toxic and detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of aggressive chemicals in critical conditions of
extreme temperature and pressure. extreme temperature and pressure.
Electronic transmitter Electronic transmitter
No transmitter supplied 0 No transmitter supplied 0
MSP 2002-1 (330 pF) 1 MSP 2002-1 (330 pF) 1
Process connection Process connection and pressure rating
¾" A Welded flange, 316L stainless steel, raised face
1" B 2" ASME, 150 lb AA
1¼" C 2" ASME, 300 lb AB
1½" D 3" ASME, 150 lb BA
2" E 3" ASME, 300 lb1) BB
Threaded connection and rating 4" ASME, 150 lb1) CA
NPT [(Taper), ANSI/ASME B1.20.1] A 4" ASME, 300 lb1) CB
R [(BSPT), EN 10226/PT (JIS-T) JIS B 0203] B 6" ASME, 150 lb1) DA
G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] D 6" ASME, 300 lb1) DB
Probe insulation/material of process connection Welded flange, 316L stainless steel, Type A flat
faced
PFA insulation/316L stainless steel 1
DN 50 PN 16 EC
Approvals DN 50 PN 25
5
ED
General Purpose 1
DN 80 PN 16 FC
CSA/FM Class I, Div. 2, Groups A, B, C, D T4; 2
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C; DN 80 PN 25 FD
CSA/FM Class II and III Div. 1, Groups E, F, G T4 DN 100 PN 161) GC
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4 DN 125 PN 161) HC
FM Class I, Div. 1, Groups A, B, C, D T4 6 (Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5
Probe/electrode diameter or EN 1092-1 standard.)
16 mm (0.63") rigid rod, minimum insertion length 1 Probe insulation/material of process connection
200 mm (7.9"), maximum insertion length 1000 mm
(39.4")1) PFA insulation/316L stainless steel 1

Thermal isolator/remote version Approvals


Rigid thermal isolator [for process temperature over A General Purpose 1
+85 °C (+185 °F)] CSA/FM Class I, Div. 2, Groups A, B, C, D T4; 2
No thermal isolator B ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
Further designs Order code
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
Please add "-Z" to Order No. and specify Order FM Class I, Div. 1, Groups A, B, C, D T4 6
code(s).
Probe/electrode diameter
Insertion length, specify in plain text: Y01 16 mm (0.63") rigid rod, min. length 200 mm (7.9"), 1
Y01: ... mm [minimum 200 mm (7.87")] max. length 1000 mm (39.4")
Active Shield length - minimum length is Y02
50 mm.Y02: ... mm Thermal isolator/remote version
Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15 Rigid thermal isolator [for process temperature over A
suring-point number/identification (max. 20 charac- +85 °C (+185 °F)]
ters); specify in plain text No thermal isolator B
Acceptance test certificate: Manufacturer's test C11 Further designs Order code
certificate M to DIN 55350, Part 18 and ISO 9000
Please add "-Z" to Order No. and specify Order
Inspection Certificate Type 3.1 per EN 10204 C12 code(s).
Instruction manual See page 5/52 Insertion length, specify in plain text: Y01
Y01: ... mm [minimum 200 mm (7.87")]
Accessories See page 5/52
Active Shield length - minimum length is Y02
1)
Add order code Y01 and Y02 in plain text: 50 mm.Y02: ... mm2)
“Insertion/active shield length ... mm" Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
suring-point number/identification (max. 20 charac-
C) Subject to export regulations AL: N, ECCN: EAR99 ters); specify in plain text
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Instruction manual See page 5/52
Accessories See page 5/52
1)
Custom shipping methods required. Contact factory for more details
2)
See dimension drawings on page 5/59 for further explanation of Y02

C) Subject to export regulations AL: N, ECCN: EAR99

5/50 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS500, single piece flange C) 7 M L 5 6 0 3 - Pointek CLS500, single piece flange C) 7 M L 5 6 0 3 -
Inverse frequency shift capacitance level switch for 7 7 7 77 - 77 A 0 Inverse frequency shift capacitance level switch for 7 7 7 77 - 77 A 0
detecting interfaces, solids, liquids, toxic and detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of aggressive chemicals in critical conditions of
extreme temperature and pressure. extreme temperature and pressure.
Electronic transmitter Further designs Order code
No transmitter supplied 0 Please add "-Z" to Order No. and specify Order
MSP 2002-1 (330 pF) 1 code(s).
Process connection and pressure rating Insertion length, specify in plain text: Y01
Single piece flange, 316L stainless steel, raised Y01: ... mm [minimum 200 mm (7.87")]
face Active Shield length - minimum length is Y02
2" ASME, 150 lb AA 50 mm.Y02: ... mm2)
2" ASME, 300 lb AB Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
suring-point number/identification (max. 20 charac-
3" ASME, 150 lb BA ters); specify in plain text
3" ASME, 300 lb1) BB
Acceptance test certificate: Manufacturer's test C11
4" ASME, 150 lb1) CA certificate M to DIN 55350, Part 18 and ISO 9000
4" ASME, 300 lb1) CB
Inspection Certificate Type 3.1 per EN 10204 C12
6" ASME, 150 lb1) DA
Instruction manual See page 5/52
6" ASME, 300 lb1) DB
Single piece flange, 316L stainless steel, Type B1 Accessories See page 5/52
raised faced 1)
Custom shipping methods required. Contact factory for more details
DN 50 PN 16
DN 50 PN 25
EC
ED
2)
See dimension drawings on page 5/59 for further explanation of Y02
5
C) Subject to export regulations AL: N, ECCN: EAR99
DN 80 PN 16 FC
DN 80 PN 25 FD
DN 100 PN 161) GC
DN 100 PN 251) GD
DN 125 PN 161) HC
Probe insulation/material of process connection
PFA insulation/316L stainless steel 1
Approvals
General Purpose 1
CSA/FM Class I, Div. 2, Groups A, B, C, D T4; 2
ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
FM Class I, Div. 1, Groups A, B, C, D T4 6
Probe/electrode diameter
16 mm (0.63") rigid rod, maximum length 1000 mm 1
(39.4") (Y01)
Thermal isolator/remote version
Rigid thermal isolator [for process temperature over A
+85 °C (+185 °F)]
No thermal isolator B

March 2009 Siemens FI 01 · 2009 US Edition 5/51


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Selection and Ordering data Order No. Selection and Ordering data Order No.
Pointek CLS500 High temperature 7ML 5 6 0 4 - Pointek CLS500 High temperature 7ML 5 6 0 4 -
Inverse frequency shift capacitance level switch for 7 A 7 77 - 7777 Inverse frequency shift capacitance level switch for 7 A 7 77 - 7777
detecting interfaces, solids, liquids, toxic and detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of aggressive chemicals in critical conditions of
extreme temperature and pressure. extreme temperature and pressure.
Electronic transmitter Approvals
No transmitter supplied 0 General Purpose A
MSP 2002-1 (330 pF) 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T4; B
ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
Process connection and pressure rating CSA/FM Class II and III Div. 1, Groups E, F, G T4
316L stainless steel, raised face1)
2" ASME, 150 lb A1 ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C D
2" ASME, 300 lb A2 FM Class I, Div. 1, Groups A, B, C, D T4 F
2" ASME, 600 lb A3 Probe/electrode diameter
2" ASME, 900 lb A4 Maximum length 1000 mm (39.37")7) A
3" ASME, 150 lb B1 Thermal isolator/remote version
3" ASME, 300 lb2) B2 Rigid thermal isolator [for process temperature over 1
3" ASME, 600 lb2) B3 +85 °C (+185 °F)]
3" ASME, 900 lb2) B4
Further designs Order code
4" ASME, 150 lb2) C1
Please add "-Z" to Order No. and specify Order
4" ASME, 300 lb2) C2 code(s).
4" ASME, 600 lb2) C3
Insertion length, specify in plain text: Y01: ... mm Y01
5 4" ASME, 900 lb2)
6" ASME, 150 lb2)
C4
D1
Y01 for probe insulation option 1: min. = 200 mm
(7.87")
6" ASME, 300 lb2) D2 Y01 for probe insulation option 2: min. = 200 mm
(7.87")
6" ASME, 600 lb2) D3
Active Shield length, specify in plain text: Y02
6" ASME, 900 lb2) D4
Y02: ... mm
316L stainless steel, Type B1 raised face3) Y02 for probe insulation option 1: min. = 105 mm
DN 50 PN 16 E1 (4.13")
Y02 for probe insulation option 2: min. = 100 mm
DN 50 PN 25 E2
(3.94")
DN 50 PN 40 E3
Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- Y15
DN 50 PN 63 E4 suring-point number/identification (max. 20 charac-
DN 80 PN 16 F 1 ters); specify in plain text
DN 80 PN 25 F 2 Acceptance test certificate: Manufacturer's test C11
DN 80 PN 402) F 3 certificate M to DIN 55350, Part 18 and ISO 9000
DN 80 PN 632) F 4 Inspection Certificate Type 3.1 per EN 10204 C12
DN 100 PN 162) G1 Instruction manual See page 5/52
DN 100 PN 252) G2
Accessories See page 5/52
DN 100 PN 402) G3
DN 100 PN 632) G4 1)
Welded flange for no insulation option only
2)
DN 125 PN 162) H1 Custom shipping methods required. Contact factory for more details.
3)
Flat faced flange for no insulation option only
DN 125 PN 252) H2 4)
Non-conductive material only, stainless steel non-insulated probe diameter
DN 125 PN 402) H3 19 mm (0.75")
DN 125 PN 632) H4 5) Enamel insulated probe diameter 16 mm (0.63")
(Note: Flange bolting patterns and facings dimen- 6) Single piece construction for enamel option only
sionally correspond to the applicable ASME B16.5 7)
Add order code Y01 and Y02 in plain text:
or EN 1092-1 standard.) “Insertion/active shield length ... mm"
Minimum insertion length depends on probe version selected. See dimen-
Probe insulation/material of process connection sion drawings on page 5/59 for more details.
No insulation/316L stainless steel4) 7) 1
Enamel insulation/316L stainless steel5) 6) 7) 2
Selection and Ordering data Order No.
Stilling well
Instruction manual
No stilling well 0
English 7ML1998-5GG01
German 7ML1998-5GG31
French 7ML1998-5GG11
Dutch 7ML1998-5GG41
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Transmitter, MSP 2002-1, 330 PF1) L) 7ML1830-1JP
1) Transmitters not suitable for Intrinsically Safe application (ATEX II 1G EEx
ia IIC T4 or CSA/FM Class 1 Div 1 Grp A, B, C and D)
L) Subject to export regulations AL: N, ECCN: 3A991X

5/52 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

■ Characteristic curves

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5601)

March 2009 Siemens FI 01 · 2009 US Edition 5/53


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603)

5/54 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603)

March 2009 Siemens FI 01 · 2009 US Edition 5/55


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)

5/56 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)

March 2009 Siemens FI 01 · 2009 US Edition 5/57


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)

5/58 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

■ Dimensional drawings

Pointek CLS500 dimensions - Threaded Process Connections

March 2009 Siemens FI 01 · 2009 US Edition 5/59


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

Pointek CLS500 dimensions - Flanged Process Connections

5/60 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

■ Schematics

Pointek CLS500 connections


5

March 2009 Siemens FI 01 · 2009 US Edition 5/61


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500

■ Selection and Ordering Data


Pointek Specials. See note 1. Pointek Specials. See note 1.
CLS100 Polycarbonate Lid and Gasket, FKM CLS200 Mounting Bracket, 316L stainless
steel

Kit, Lid and gasket, CLS100 enclosure version A5E01163671 Spare mounting bracket A5E01163685
CLS100 Miscellaneous Parts CLS200 PROFIBUS Connector (IP65)
Custom length of cable is available only for See note 2.
7ML5501-xxx1x and 7ML5501-xxx5x
CLS200 Gasket (IP65), Synprene

Spare, PROFIBUS connector (IP65 versions A5E01163686


only)
CLS200 Miscellaneous Parts
Spare gasket, enclosure version (IP65 versions A5E01163672 CLS200 with FFKM O-rings (any version) See note 2.
only)
CLS300 Cable Extensions, 316L stainless

5 CLS200 Gasket (IP68), Silicone steel

Kit, Stainless steel cable extension, 1 m, adjust- A5E01163688


Spare gasket, enclosure version (IP68 versions) A5E01163673 able by customer
CLS200 Blind Lid Kit, Stainless steel cable extension, 3 m, adjust- A5E01163689
able by customer
Kit, Stainless steel cable extension, 5 m, adjust- A5E01163690
able by customer
Kit, Stainless steel cable extension, 10 m, adjust- A5E01163691
able by customer
Spare aluminum blind lid (for standard versions A5E01163674 Kit, Stainless steel cable extension, 15 m, adjust- A5E01163693
only) able by customer
CLS200 Lid with window Kit, Stainless steel cable extension, 20 m, adjust- A5E01163695
able by customer
CLS300 Cable Extensions, 316 stainless steel
with PFA coating

Spare aluminum lid with window A5E01163676


CLS200 Sensor Kit for cable units
Kit, PFA cable extension, 1 m, adjustable by cus- A5E01163697
tomer
Kit, PFA cable extension, 3 m, adjustable by cus- A5E01163698
tomer
Kit, PFA cable extension, 5 m, adjustable by cus- A5E01163699
tomer
Kit, Sensor for cable units, PPS, Standard, FKM A5E01163677 C)
Kit, PFA cable extension, 10 m, adjustable by A5E01163700
Kit, Sensor for cable units, PPS, Digital, FKM A5E01163678 C) customer
Kit, Sensor for cable units, PPS, Standard, FFKM A5E01163679 C) Kit, PFA cable extension, 15 m, adjustable by A5E01163701
customer
Kit, Sensor for cable units, PPS, Digital, FFKM A5E01163680 C)
Kit, PFA cable extension, 20 m, adjustable by A5E01163702
Kit, Sensor for cable units, PVDF, Standard, FKM A5E01163681 C) customer
Kit, Sensor for cable units, PVDF, Digital, FKM A5E01163682 C)
Kit, Sensor for cable units, PVDF, Standard, A5E01163683 C)
FFKM
Kit, Sensor for cable units, PVDF, Digital, FFKM A5E01163684 C)

5/62 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Capacitance switches
Pointek CLS500
Pointek Specials. See note 1. Pointek Specials. See note 1.
CLS300 Rod Kits, 316L stainless steel CLS500 Gasket (IP65), Silicone

Kit, Stainless steel rod 180 mm (7.09") to be used A5E01163719 Spare gasket, CLS500 enclosure version, IP65 A5E01163728 C)
with CLS300 units only (with standard active
shield). Insertion length after installation is 350 CLS500 Blind Lid
mm (13.78").
Kit, Stainless steel rod 330 mm (12.99") to be A5E01163720
used with CLS300 units only (with standard
active shield). Insertion length after installation is
500 mm (19.69").
Kit, Stainless steel rod 580 mm (22.83") to be A5E01163721 Spare CLS500 aluminum blind lid A5E01163729
used with CLS300 units only (with standard
active shield). Insertion length after installation is Note 1: Special flange sizes and facings are available. Please
750 mm (29.53"). contact nacc.smpi@siemens.com for part number and pricing.
Kit, Stainless steel rod 830 mm (32.68") to be A5E01163722 Submit Application Questionnaire found on page 5/8.
used with CLS300 units only (with standard
active shield). Insertion length after installation is Note 2: Please contact nacc.smpi@siemens.com for part num-
1000 mm (39.37"). ber and pricing.
Kit, Stainless steel rod 1330 mm (52.36") to be
used with CLS300 units only (with standard
active shield). Insertion length after installation is
See note 2. Note 3: For General Purpose approvals only.
Note 4: To maintain approvals, qualified trained Siemens person-
5
1500 mm (59.06"). nel required for part replacement.
Kit, Stainless steel rod 1830 mm (72.05") to be See note 2. Please contact nacc.smpi@siemens.com for special requests.
used with CLS300 units only (with standard
active shield). Insertion length after installation is
2000 mm (78.74").
C) Subject to export regulations AL: N, ECCN: EAR99
Kit, Stainless steel rod customized length up to 1 m See note 2.
Kit, Stainless steel rod customized length up to 2 m See note 2.
CLS300 Electronics Kits with drivers (for rod
or cable versions)

Kit, Electronics with driver, standard CLS300. To A5E01163723 C)


be used in rod or cable versions with length less
than 5 m. See note 3 and 4.
Kit, Electronics with driver, digital CLS300. To be A5E01163725 C)
used in rod or cable versions with length less
than 5 m. See note 3 and 4.
CLS300 Electronics Kits with drivers (for
cable versions)

Kit, Electronics with driver, standard CLS300. To A5E01163724


be used in cable versions with length greater
than 5 m. See note 3 and 4.
Kit, Electronics with driver, digital CLS300. To be A5E01163726
used in cable versions with length greater than
5 m. See note 3 and 4.
CLS300 Weight Kit, 316L stainless steel

Kit, Spare stainless steel weight. To be used in A5E01163727


any cable version of CLS300

March 2009 Siemens FI 01 · 2009 US Edition 5/63


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL100

■ Overview ■ Configuration

SITRANS LVL100 is a compact vibrating level switch for use in


liquid applications such as overflow, high, low and demand ap-
plications, as well as pump protection. It is ideal for use in con-
fined spaces.
5
■ Benefits
• Proven vibrating level switch technology for liquids
• Compact insertion length of 40 mm (1.57”) for confined space
applications
• Fault monitoring for corrosion, loss of vibration, or line break to
the piezo drive

■ Application
SITRANS LVL100 is a compact level switch designed for indus-
trial use in all areas of process technology and can be used with
liquids and slurries. With an insertion length of only 40 mm
(1.57“), SITRANS LVL100 can be mounted in small pipes and
confined space applications. It is also virtually unaffected by the
chemical and physical properties of the liquid. The LVL100 can
also be used in difficult conditions including turbulence, air bub-
bles, foam generation, buildup, or strong external vibration.
The tuning fork is piezoelectrically energized and vibrates at its
mechanical resonance frequency of approximately 1200 Hz.
The vibration frequency changes when the tuning fork is cov-
ered by the medium. This change is detected by the integrated
oscillator and converted into a switching command. The inte-
grated electronics evaluate the level signal and output a switch-
ing signal, directly operating connected devices.
• Key Applications: For use in liquids and slurries, for level mea-
surement, overfill, and dry run protection

SITRANS LVL100 Installation

5/64 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL100

■ Technical specifications Selection and Ordering data Order No.


SITRANS LVL100 7ML 5 7 4 5 -
Mode of operation Compact vibrating level switch for use in liquid
7 7 7 77 - 77 A 0
Measuring principle Vibrating point level switch applications such as overflow, high, low and
demand applications, as well as pump protection.
Input Ideal for use in confined spaces.
Measured variable High and low and demand Approvals
Output Without approvals 1
Shipping approvals 2
Output options • Contactless electronic switch Overfill protection (WHG)1) 3
• Transistor output PNP Process temperature
Measuring Accuracy Standard -40 to 100 °C (-40 to 212 °F)2) A
Extended -40 to 150 °C (-40 to 302 °F)2) B
• Hysteresis approx. 2 mm (0.08”) with vertical
installation Hygienic applications -40 to 150 °C (-40 to 302 °F)3) C
Process connection
• Switching delay approx. 500 ms (on/off)
Thread G¾" A PN64/316L A0
• Frequency approx. 1200 Hz Thread G¾" A PN64/316L Ra<0.8µm A1
Rated operating conditions Thread ¾" NPT PN64/316L A2
Installation conditions Thread ¾" NPT PN64/316L Ra<0.8µm A3
Thread G1" A PN64/316L A4
• Location Indoor/outdoor
Thread G1" A PN64/316L Ra<0.8µm A5
Ambient conditions Thread 1" NPT PN64/316L A6
• Ambient temperature -40 to +70 °C (-40 to +158 °F) Thread 1" NPT PN64/316L Ra<0.8µm A7
• Installation category III Tri-Clamp 1" PN16/316L Ra<0.8µm
Tri-Clamp 1½" PN16/316L Ra<0.8µm
A8
B0
5
• Pollution degree 2
Tri-Clamp 2" PN16/316L Ra<0.8µm B1
Medium conditions
Bolting DN25 PN40 DIN11851/316L Ra<0.8µm B2
• Temperature Bolting DN40 PN40 DIN11851/316L Ra<0.8µm B3
- Standard -40 to +100 °C (-40 to +212 °F) Bolting DN50 PN25 DIN11851/316L Ra<0.8µm B4
- High temperature option -40 to +150 °C (-40 to +302 °F) SMS DN38 PN6/316L Ra<0.8µm B5
Hygienic fitting with compression nut F40 B6
• Pressure (vessel) -1 to 64 bar g (-14.5 to 928 psi g) PN25/316L Ra<0.8µm
• Density 0.7 to 2.5 g/cm³ (0.025 to Electronics
0.09 lbs/in³) Contactless electronic switch 20 to 250 V AC/DC4) 1
Design Transistor output PNP 10 to 55 V DC 2
• Material Housing
- Enclosure 316L and Plastic PEI 316L 1
Electrical connection/Protection
- Tuning fork 316L (1.4404 or 1.4435)
M12x1/IP67 A
- Process connection (threaded) 316L (1.4404 or 1.4435) According to DIN 43650 including plug/IP65 B
- Process seal Klingersil C-4400 Acc. to DIN43650 incl. plug with QuickOn connec- C
tion/IP65
• Process connection
M12x1 incl. 5 m cable/IP68 (0.2 bar) D
- Pipe thread, cylindrical G ¾” A or G 1” A
(ISO 228 T1) Further designs Order code

- Pipe thread, tapered ¾” NPT or 1” NPT Please add "-Z" to Order No. and specify Order
code(s).
- Hygienic fittings Bolting DN40 PN40
Cleaning including Certificate (oil, grease and sili- W01
Tri-clamp 1”, 1½”, 2” PN 10 cone free)
• Degree of protection IP65/Type 4/NEMA 4 (with DIN Identification Label, foil laser marking Y16
43650 valve plug), IP66/67 or
IP68 (with M12 connector) Additional instruction manual Order No.
LVL100 (Contactless electronic switch), English 7ML1998-5KN01
• Conduit entry 1 x M12 [IP66/IP67 or IP68 LVL100 (Contactless electronic switch), French 7ML1998-5KN11
(0.2 bar)]
LVL100 (Contactless electronic switch), Spanish 7ML1998-5KN21
• Weight (housing) 250 g (9 oz) LVL100 (Contactless electronic switch), German 7ML19985-KN31
Power supply LVL100 (Transistor PNP), English 7ML1998-5KP01
• Supply voltage 20 to 253 V AC, 50/60 Hz LVL100 (Transistor PNP), French 7ML1998-5KP11
LVL100 (Transistor PNP), Spanish 7ML1998-5KP21
20 to 253 V DC
LVL100 (Transistor PNP), German 7ML1998-5KP31
• Power consumption 1 to 8 VA (AC), approx. 1.3 W
(DC) This device is shipped with the Siemens Milltronics
manual CD containing the complete instruction
Certificates and approvals • Overfill protection (WHG) manual library.
• Shipping approvals 1)
Available with Electronics option 2 only
2) Available with process connection A0, A2, A4, and A6 only
3)
Available with process connection A1, A3, A5, and A7 to B6 only
4)
Available with Electrical connection/Protection option B and C only

March 2009 Siemens FI 01 · 2009 US Edition 5/65


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL100

■ Characteristic curves

SITRANS LVL100 Ambient Temperature/Process Temperature derating curves

5/66 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL100

■ Dimensional drawings

SITRANS LVL100 dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/67


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL100

■ Schematics

SITRANS LVL100 connections

5/68 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

■ Overview ■ Configuration

SITRANS LVL200 is a standard vibrating level switch for use in


all liquid and slurry applications such as overflow, high, low, and
demand applications, as well as pump protection. For use in
SIL-2 applications.
5
■ Benefits
• Proven vibrating level switch technology for liquids
• Compact insertion length of 40 mm (1.57”) for confined space
applications
• Fault monitoring for corrosion, loss of vibration or line break to
the piezo drive
• SIL-2 qualified for high level and dry run applications
• Hygienic process connections

■ Application
SITRANS LVL200 is a level switch designed for industrial use in
all areas of process technology and can be used with liquids
and slurries. With a tuning fork insertion length of only 40 mm
(1.57“), SITRANS LVL200 can be mounted in small pipes and
applications with confined space. The LVL200 can be used to
measure products with a minimum density of >0.5 g/cm³
(0.018 lbs/in³). The LVL200 can be used in difficult conditions in-
cluding turbulence, air bubbles, foam generation, buildup, or
strong external vibration.
SITRANS LVL200 continuously monitors faults via frequency
evaluation, providing early detection of strong corrosion or
damage on the tuning fork, loss of vibration, or a line break to the
piezo drive.
The tuning fork is piezoelectrically energized and vibrates at its
mechanical resonance frequency of approx. 1200 Hz. The vibra-
tion frequency changes when the tuning fork is covered by the
medium. This change is detected by the integrated oscillator
and converted into a switching command. The integrated elec-
tronics evaluate the level signal and output a switching signal,
directly operating connected devices.
• Key Applications: For use in liquids and slurries, for level mea-
surement, overfill, and dry run protection

SITRANS LVL200 Installation

March 2009 Siemens FI 01 · 2009 US Edition 5/69


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

■ Technical specifications • Degree of protection Type 4X/NEMA 4X/IP66/IP67


• Conduit entry • 1 x M20x1.5 (cable: ø5 to 9 mm),
Mode of operation 1 x blind stopper M20x1.5; at-
Measuring principle Vibrating point level switch tached 1 x M20x1.5 cable entry
Input • 1 x ½” NPT cable entry, 1 x blind
stopper ½”NPT, 1 x ½” NPT ca-
Measured variable High and low and demand (via ble entry
mode switch)
• 1x M12x1; 1 x blind stopper
Output M20x1.5
Output options Relay output (DPDT), 2 floating • Weight
SPDTs
- Device weight (dependent on approx. 0.8 to 4 kg (0.18 to
Measuring Accuracy process fitting) 8.82 lbs)
• Repeatability 0.1 mm (0.004”) - Tube extension (extended ver- approx 920 g/m (10 oz/ft)
• Hysteresis approx. 2 mm (0.08”) with vertical sion)
installation Power supply
• Switching delay approx. 500 ms (on/off) Supply voltage
• Frequency approx. 1200 Hz • Relay DPDT 20 to 253 V AC, 50/60 Hz, 20 to
72 V DC [at U>60 V DC, the ambi-
Rated operating conditions ent temperature can be max.
Installation conditions 50 °C (122 °F)]
• Location Indoor/outdoor Power consumption 1 to 8 VA (AC), approx. 1.3 W
(DC)
Ambient conditions
5 • Ambient temperature -40 to +70 °C (-40 to +158 °F)
Certificates and approvals • CE
• Overfill protection (WHG)
• Installation category III • FM (Non-Incendive) Class I,
• Pollution degree 2 Div. 2, Groups A, B, C, D
Medium conditions • FM (Explosion-Proof) Class I,
Div. 1, Groups A, B, C, D; (Dust
• Temperature Ignition-Proof) Class II, III, Div. 1,
Groups E, F, G1)
- LVL200S Standard -50 to +150 °C (-58 to +302 °F)
• Shipping approvals
- LVL200S High temperature op- -50 to +250 °C (-58 to +482 °F)
tion
- LVL200E Standard: with -50 to +150 °C (-58 to +302 °F)
316L/Hastelloy C4 (2.4610)
- LVL200E High temperature op- -50 to +250 °C (-58 to +482 °F)
tion: with 316L/Hastelloy C4
(2.4610)
• Pressure (vessel) -1 to 64 bar g (-14.5 to 928 psi g)
• Density 0.7 to 2.5 g/cm³ (0.025 to
0.09 lbs/in³); 0.5 to 2.5 g/cm³
(0.018 to 0.09 lbs/in³) by switch-
ing over
Design
• Material
- Enclosure Aluminum die-cast AISi10Mg,
powder-coated, basis: Polyester
- Tuning fork 316L (1.4404 or 1.4435), Hastel-
loy C4 (2.4602)
- Extension tube [ø 21.3 mm 316L (1.4404 or 1.4435), Hastel-
(0.839”)] loy C4 (2.4602)
- Process connection: threaded 316L (1.4404 or 1.4435), Hastel-
loy C4 (2.4602)
- Process connection: flange 316L (1.4404 or 1.4435), 316L
with Hastelloy C4, ECTFE, or PFA
coating
- Process seal Klingersil C-4400
• Process connection
- Pipe thread, cylindrical G ¾” A, G 1” A
(ISO 228 T1)
- Pipe thread, tapered ¾” NPT, 1” NPT, 1½” NPT
- Flanges DIN from DN25, ANSI from 1”
- Hygienic fittings Bolting DN40 PN40, 1, 1½, 2, 2½”
Tri-Clamp PN 10, conus DN25
PN 40, Tuchenhagen Varivent
DN50 PN10, SMS

5/70 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVL200, Standard 7ML 5 7 4 6 - SITRANS LVL200, Standard 7ML 5 7 4 6 -
Compact vibrating level switch for use in liquid Compact vibrating level switch for use in liquid
7 7 7 77 - 77 A 0 7 7 7 77 - 77 A 0
applications such as overflow, high, low and applications such as overflow, high, low and
demand applications, as well as pump protection. demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications. For use in SIL-2 and hazardous applications.
Electronics Tri-Clamp 3", PN10/316L Ra<0.3µm A50
Double relay (DPDT) 20 to 72 V DC/20 to 250 V AC 2 Tri-Clamp 3", PN10/316L Ra<0.8µm A51
Approvals Bolting DN32, PN40 DIN11851/316L Ra<0.3µm A52
Without approvals A Bolting DN32, PN40 DIN11851/316L Ra<0.8µm A53
Overfill protection (WHG) B Bolting DN25, PN40 DIN11851/316L Ra<0.3µm A54
Shipping approvals K Bolting DN25, PN40 DIN11851/316L Ra<0.8µm A55
FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP) P Bolting DN40, PN40 DIN11851/316L Ra<0.3µm A56
Class II, III, Div. 1, Groups E, F, G Bolting DN40, PN40 DIN11851/316L Ra<0.8µm A57
FM (NI) Class I, Div. 2, Groups A, B, C, D Q Bolting DN 40, PN40 DIN11864-1 A/316L A58
Process connection Ra<0.8µm ZB3052
Thread G¾" A, PN64/316L A00 Bolting DN50, PN25 DIN11851/316L Ra<0.3µm A60
Thread G¾" A, PN64/316L Ra<0.8µm A01 Bolting DN50, PN25 DIN11851/316L Ra<0.8µm A61
Thread ¾" NPT, PN64/316L A02 Bolting DN50, PN25 DIN11864-1 A/316L Ra<0.8µm A62
ZB3052
Thread ¾" NPT, PN64/316L Ra<0.8µm A03
Thread ¾" NPT, PN64/Monel A04 Hygienic w. compr. nut F40, PN25/316L A63
Thread G¾" A, PN64/Hastelloy C4 (2.4610) A05 Hygienic w. compr. nut F40, PN25/316L Ra<0.3µm A64
Hygienic w. compr. nut F40, PN25/316L Ra<0.8µm A65
Thread ¾" NPT, PN64/Hastelloy C4 (2.4610) A06
Thread G1" A, PN64/316L
Thread G1" A, PN64/316L ECTFE coated MB19821)
A07
A08
Varivent N50-40/316L Ra<0.3µm
Varivent N50-40/316L Ra<0.8µm
A66
A67
5
1) Varivent N125/100/316L Ra<0.8µm A68
Thread G1" A, PN64/316L PFA coated A10
Thread G1" A, PN64/Monel A11 DRD flange, PN40/316L ZB3007 A70
Thread G1" A, PN64/316L Ra<0.8µm A12 SMS DN38/316L Ra<0.8µm1) A71
SMS DN51, PN6/316L Ra<0.8µm1) A72
Thread 1" NPT, PN64/316L A13
Thread 1" NPT, PN64/316L ECTFE coated A14 Swagelok VCR screwing ZG2579, PN64/316L A73
MB19821) Neumo biocontrol Gr. 25, PN16/316L Ra<0.8µm A74
Thread 1" NPT, PN64/316L PFA-coated1) A15 Neumo biocontrol Gr. 50, PN16/316L Ra<0.8µm1) A75
Thread 1" NPT, PN64/Monel A16 Neumo biocontrol Gr. 65, PN16/316L Ra<0.8µm A76
Thread 1" NPT, PN64/316L Ra<0.8µm A17 Neumo biocontrol Gr. 80, PN16/316L Ra<0.8µm A77
Thread G1" A, PN64/Hastelloy C4(2.4610) A18 SÜDMO DN50, PN10/316L/316L Ra<0,8µm A78
Thread G1" A, PN64/Hastelloy C4(2.4610) A20 Small flange DN25, PN1.5 DIN 28403/316L A80
Ra<0.3µm pol.Ra<0.8µm
Thread G1½" A, PN64/316L A21 Small flange DN40, PN1.5 DIN 28403/316L A81
Thread G1½" A, PN64/316L Ra<0,8µm A22 pol.Ra<0.8µm
Ingold connection, PN16/316L Ra<0.8µm A82
Thread G1½" A, PN64/Hastelloy C4(2.4610) A23
Thread 1" NPT, PN64/Hastelloy C4(2.4610) A24 Ingold connection, PN16/Hastelloy C4 Ra<0.8µm A83
Thread 1½" NPT, PN64/316L A25 Terminal DN 33,7 PN40 DIN11864-3-A-/316L BN2 A84
Ra<0.8µm1)
Thread 1½" NPT, PN64/316L Ra<0,8µm A26 Hygienic fl. DN50 PN16 DIN11864-2-A-/316L A85
Thread 1½" NPT, PN64/Hastelloy C4(2.4610) A27 Ra<0.8µm
Thread G2" A, PN64/316L A28
Flange DN25, PN6 Form C, DIN 2501/316L A86
Thread M27x1.5, PN64/316L A30 Flange DN25, PN6 Form C, DIN 2501/PFA1) A87
Conus DN25, PN40/316L Ra<0.3µm A31 Flange DN25, PN40 Form C, DIN 2501/316L A88
Conus DN25, PN40/316L Ra<0.8µm A32
Flange DN25, PN40 Form C, DIN 2501/Hastelloy B00
Conus DN25, PN40/ECTFE (ZB3033)1) A33 C4(2.4610)
Conus M52, PN40/316L A34 Flange DN25, PN40 Form C, DIN 2501/ECTFE1) B01
Conus M52, PN40/316L Ra<0.3µm A35 Flange DN25, PN40 Form C, DIN 2501/PFA1) B02
Conus M52, PN40/316L Ra<0.8µm A36 Flange DN25, PN40 Form C, DIN 2501/Enamelled B03
Tri-Clamp 1", PN16/316L Ra<0.3µm A37 Flange DN25, PN40 Form D, DIN 2501/316L B04
Tri-Clamp 1", PN16/Hastelloy C4(2.4610) A38 Flange DN25, PN40 Form F, DIN 2501/316L B05
Ra<0.8µm
Flange DN25, PN40 Form N, DIN 2501/316L B06
Tri-Clamp 1", PN16/316L Ra<0.8µm A40 Flange DN25, PN40 Form N, DIN 2501/Hastelloy B07
Tri-Clamp 1½", PN16/316L Ra<0.3µm A41 C4 solid
Tri-Clamp 1½", PN16/Hastelloy C4(2.4610) A42 Flange DN25, PN40 Form N, DIN 2501/Monel solid B18
Ra<0.8µm
Flange DN25, PN40 V13, DIN 2501/316L B10
Tri-Clamp 1½", PN16/316L Ra<0.8µm A43 Flange DN32, PN40 Form C, DIN 2501/316L B11
Tri-Clamp 2", PN16/316L Ra<0.3µm A44 Flange DN32, PN40 Form C, DIN 2501/ECTFE1) B12
Tri-Clamp 2", PN16/Hastelloy C4(2.4610) A45
Ra<0.8µm Flange DN40, PN6 Form C, DIN 2501/316L B13
Flange DN40, PN6 Form C, DIN 2501/ECTFE1) B14
Tri-Clamp 2", PN16/316L Ra<0.8µm A46 Flange DN40, PN40 Form C, DIN 2501/316L B15
Tri-Clamp 2½", PN10/316L Ra<0.3µm A47
Tri-Clamp 2½", PN10/316L Ra<0.8µm A48 Flange DN40, PN40 Form C, DIN 2501/Hastelloy B16
C4(2.4610)
Flange DN40, PN40 Form C, DIN 2501/ECTFE1) B17

March 2009 Siemens FI 01 · 2009 US Edition 5/71


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVL200, Standard 7ML 5 7 4 6 - SITRANS LVL200, Standard 7ML 5 7 4 6 -
Compact vibrating level switch for use in liquid Compact vibrating level switch for use in liquid
7 7 7 77 - 77 A 0 7 7 7 77 - 77 A 0
applications such as overflow, high, low and applications such as overflow, high, low and
demand applications, as well as pump protection. demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications. For use in SIL-2 and hazardous applications.
Flange DN40, PN40 Form C, DIN 2501/PFA1) B18 Flange DN100, PN40 Form N, DIN 2501/316L B76
Flange DN40, PN40 Form C, DIN 2501/Enamelled2) B20 Flange DN100, PN40 V13, DIN 2501/316L B77
Flange DN40, PN40 Form F, DIN 2501/316L B21 Flange DN100, PN64 Form E, DIN 2501/316L B78
Flange DN40, PN40 Form N, DIN 2501/316L B22 Flange DN100, PN100 Form E, DIN 2501/316L B80
Flange DN40, PN40 Form E, DIN 2501/316L B23 Flange DN100, PN100 Form L, DIN 2501/316L B81
Flange DN40, PN40 V13, DIN 2501/316L B24 Flange DN125, PN16 Form F, DIN 2501/316L B82
Flange DN50, PN40 Form C, DIN 2501/316L B25
Flange DN50, PN40 Form C, DIN 2501/Hastelloy B26 Flange DN125, PN40 Form C, DIN 2501/316L B83
C4(2.4610) Flange DN125, PN40 Form N, DIN 2512/ 316L B84
Flange DN50, PN40 Form C, DIN 2501/ECTFE1) B27 Flange DN150, PN16 Form C, DIN 2501/316L B85
Flange DN50, PN40 Form C, DIN 2501/ECTFE B28 Flange DN150, PN16 Form C, DIN 2501/Hastelloy B86
(ZB3108)1) C4(2.4610)
Flange DN50, PN40 Form C, DIN 2501/PFA1) B30 Flange DN150, PN16 Form C, DIN 2501/ECTFE1) B87
Flange DN50, PN40 Form D, DIN 2501/316L B31 Flange DN150, PN16 Form C, DIN 2501/PFA1) B88
Flange DN50, PN40 Form D, DIN 2501/Hastelloy B32 Flange DN150, PN16 Form D, DIN 2501/316L C00
C4(2.4610) Flange DN150, PN40 Form C, DIN 2501/316L C01
Flange DN50, PN40 Form F, DIN 2501/316L B33 Flange DN150, PN40 Form C, DIN 2501/Hastelloy C02
C4(2.4610)
5
Flange DN50, PN40 Form N, DIN 2501/316L B34
Flange DN50, PN40 Form N, DIN 2501/Hastelloy B35 Flange DN150, PN40 Form F, DIN 2501/316L C03
C4(2.4610) Flange DN150, PN40 Form N, DIN 2512/316L C04
Flange DN50, PN40 Form E, DIN 2501/316L B36 Flange DN200, PN10 Form C, DIN 2501/ECTFE1) C05
Flange DN50, PN40 V13, DIN 2501/316L B37 Flange DN200, PN16 Form C, DIN 2501/316L C06
Flange DN50, PN40 R13, DIN 2501/316L B38 Flange DN25, PN40 Form B1, EN 1092-1/316L C07
Flange DN50, PN64 Form F, DIN 2501/316L B40 Flange DN25, PN40 Form B1, EN 1092-1/Hastelloy C18
Flange DN50, PN64 Form N, DIN 2501/Hastelloy B41 C4(2.4610)
C4(2.4610) Flange DN25, PN40 Form B1, EN/ 316L/ PFA1) C10
Flange DN50, PN64 Form C, DIN 2501/316L B42 Flange DN25, PN40 Form B1, EN 1092-1/Enam- C11
Flange DN50, PN64 Form L, DIN 2501/316L B43 elled 2)
Flange DN50, PN100 Form E, DIN 2501/316L B44 Flange DN25, PN40 Form B2, EN 1092-1/316L C12
Flange DN50, PN100 Form L, DIN 2501/316L B45 Flange DN25, PN40 Form F, EN 1092-1/316L C13
Flange DN65, PN40 Form C, DIN 2501/316L B46 Flange DN25, PN63 Form B1, EN 1092-1/316L C14
Flange DN65, PN40 Form C, DIN 2501/Hastelloy B47 Flange DN25, PN100 Form B2, EN 1092-1/316L C15
C4(2.4610) Flange DN40, PN40 Form B1, EN/ 316L C16
Flange DN65, PN40 Form C, DIN 2501/ECTFE1) B48 Flange DN40, PN40 Form B1, EN 1092-1/PFA1) C17
Flange DN65, PN40 Form C, DIN 2501/PFA1) B50 Flange DN40, PN40 Form B2, EN/316L C18
Flange DN65, PN40 Form F, DIN 2501/316L B51 Flange DN50, PN40 Form B1, EN/316L C20
Flange DN65, PN64 Form E, DIN 2501/316L B52 Flange DN50, PN40 Form B1, EN 1092-1/Hastelloy C21
Flange DN80, PN40 Form C, DIN 2501/316L B53 C4(2.4610)
Flange DN80, PN40 Form C, DIN 2501/Hastelloy B54 Flange DN50, PN40 Form B1, EN 1092-1/Monel C22
C4(2.4610) ZB2977
Flange DN80, PN40 Form C, DIN 2501/ECTFE1) B55 Flange DN50, PN40 Form B1, EN 1092-1/ECTFE1) C23
Flange DN80, PN40 Form C, DIN 2501/PFA1) B56 Flange DN50, PN40 Form B1, EN/ 316L/PFA1) C24
Flange DN80, PN40 Form C, DIN 2501/Enamelled2) B57 Flange DN50, PN40 Form B1, EN 1092- C25
1/Enamelled2)
Flange DN80, PN40 Form F, DIN 2501/316L B58
Flange DN80, PN40 Form N, DIN 2501/316L B60 Flange DN50, PN40 Form C, EN 1092-1/316L C26
Flange DN80, PN40 Form N, DIN 2501/Hastelloy B61 Flange DN50, PN40 Form D, EN/316L C27
C4(2.4610) Flange DN50, PN40 Form D, EN 1092-1/Hastelloy C28
C4(2.4610)
Flange DN100, PN16 Form C, DIN 2501/316L B62
Flange DN100, PN16 Form C, DIN 2501/Hastelloy B63 Flange DN50, PN40 Form B2, EN 1092-1/316L C30
C4(2.4610) Flange DN50, PN40 Form E, EN 1092-1/316L C31
Flange DN100, PN16 Form C, DIN 2501/ECTFE1) B64 Flange DN80, PN40 Form B1, EN 1092-1/316L C32
Flange DN100, PN16 Form C, DIN 2501/PFA1) B65 Flange DN80, PN40 Form B1, EN 1092-1/Hastelloy C33
Flange DN100, PN16 Form C, DIN B66 C4(2.4610)
2501/Enamelled2) Flange DN80, PN40 Form B1, EN 1092-1/ECTFE1) C34
Flange DN100, PN16 Form D, DIN 2501/316L B67 Flange DN80, PN40 Form B1, EN 1092- C35
1/Enamelled2)
Flange DN100, PN16 Form F, DIN 2501/316L B68
Flange DN100, PN16 Form N, DIN 2501/316L B70 Flange DN80, PN40 Form B2, EN 1092-1/316L C36
Flange DN100, PN40 Form C, DIN 2501/316L B71 Flange DN100, PN16 Form B1, EN 1092-1/316L C37

Flange DN100, PN40 Form C, DIN 2501/ECTFE1) B72 Flange DN100, PN16 Form B1, EN 1092-1/Hastel- C38
loy C4(2.4610)
Flange DN100, PN40 Form C, DIN 2501/PFA1) B73
Flange DN100, PN40 Form C, DIN B74 Flange DN100, PN16 Form B1, EN 1092- C40
2501/Enamelled2) 1/Enamelled2)
Flange DN100, PN40 Form B1, EN 1092-1/316L C41
Flange DN100, PN40 Form F, DIN 2501/316L B75

5/72 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVL200, Standard 7ML 5 7 4 6 - SITRANS LVL200, Standard 7ML 5 7 4 6 -
Compact vibrating level switch for use in liquid Compact vibrating level switch for use in liquid
7 7 7 77 - 77 A 0 7 7 7 77 - 77 A 0
applications such as overflow, high, low and applications such as overflow, high, low and
demand applications, as well as pump protection. demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications. For use in SIL-2 and hazardous applications.
Flange DN100, PN40 Form B1, EN 1092- C42 Flange 3" 150lb RF, ANSI B16.5/316L D12
1/Enamelled2)
Flange 3" 150lb RF, ANSI B16.5/Hastelloy D13
Flange DN100, PN40 Form C, EN 1092-1/316L C43 C4(2.4610)
Flange DN100, PN63 Form B2, EN 1092-1/316L C44
Flange 3" 150lb RF, ANSI B16.5/ECTFE1) D14
Flange DN150, PN16 Form B1, EN 1092-1/316L C45
Flange DN150, PN16 Form B1, EN 1092-1/PFA1) C46 Flange 3" 150lb RF, ANSI B16.5/PFA1) D15
Flange DN150, PN40 Form B1, EN 1092-1/316L C47 Flange 3" 150lb RF, ANSI B16.5/Enamelled2) D16
Flange 3" 150lb FF, ANSI B16.5/316L D17
Flange DN150, PN40 Form B1, EN 1092-1/ECTFE1) C48 Flange 3" 150lb FF, ANSI B16.5/ECTFE1) D18
Flange DN150, PN40 Form B2, EN 1092-1/316L C50
Flange 1" 150lb ANSI B16.5/316L C51 Flange 3" 150lb FF, ANSI B16.5/PFA1) D20
Flange 3" 300lb RF, ANSI B16.5/316L D21
Flange 1" 150lb RF, ANSI B16.5/Hastelloy C52 Flange 3" 300lb RF, ANSI B16.5/Hastelloy D22
C4(2.4610) C4(2.4610)
Flange 1" 150lb RF, ANSI B16.5/Monel ZB2977 C53
Flange 1" 150lb RF, ANSI B16.5/ECTFE1) C54 Flange 3" 300lb RF, ANSI B16.5/ECTFE1) D23
Flange 1" 150lb RF, ANSI B16.5/PFA1) C55 Flange 3" 300lb RF, ANSI B16.5/PFA1) D24
Flange 3" 300lb RF, ANSI B16.5/Enameled2) D25
Flange 1" 150lb RF, ANSI B16.5/Enamelled2) C56
Flange 1" 300lb RF, ANSI B16.5/316L C57 Flange 3" 600lb RF, ANSI B16.5/316L D26
Flange 1"300lb RF, ANSI B16.5/ECTFE1) Flange 3½" 150lb RF, ANSI B16.5/316L
5
C58 D27
Flange 3½" 150lb RF, ANSI B16.5/ECTFE1) D28
Flange 1" 600lb RF, ANSI B16.5/316L C60
Flange 1½" 150lb RF, ANSI B16.5/316L C61 Flange 4" 150lb RF, ANSI B16.5/316L D30
Flange 1½" 150lb RF, ANSI B16.5/Hastelloy C62 Flange 4" 150lb RF, ANSI B16.5/Hastelloy D31
C4(2.4610) C4(2.4610)
Flange 4" 150lb RF, ANSI B16.5/ECTFE1) D32
Flange 1½" 150lb RF, ANSI B16.5/ECTFE1) C63
Flange 1½" 150lb RF, ANSI B16.5/PFA1) C64 Flange 4" 150lb RF, ANSI B16.5/PFA1) D33
Flange 1½" 150lb RF, ANSI B16.5 Enamelled2) C65 Flange 4" 150lb RF, ANSI B16.5/Enamelled2) D34
Flange 4" 150lb LT, ANSI B16.5/316L D35
Flange 1½" 150lb FF, ANSI B16.5/ECTFE1) C66
Flange 1½" 300lb RF, ANSI B16.5/316L C67 Flange 4" 300lb RF, ANSI B16.5/316L D36
Flange 1½" 300lb RF, ANSI B16.5/Monel ZB2977 C68 Flange 4" 300lb RF, ANSI B16.5/Hastelloy D37
C4(2.4610)
Flange 1½" 300lb RF, ANSI B16.5/ECTFE2) C70 Flange 4" 300lb RF, ANSI B16.5/ECTFE1) D38
Flange 1½" 600lb RF, ANSI B16.5/316L C71
Flange 4" 300lb RJF, ANSI B16.5/316L D40
Flange 2" 150lb RF, ANSI B16.5/316L C72
Flange 4" 300lb LG, ANSI B16.5/316L D41
Flange 2" 150lb RF, ANSI B16.5/Hastelloy C73 Flange 4" 300lb LT, ANSI B16.5/316L D42
C4(2.4610)
Flange 2" 150lb RF, ANSI B16.5/Monel ZB2977 C74 Flange 4" 600lb RF, ANSI B16.5/316L D43
Flange 2" 150lb RF, ANSI B16.5/ECTFE1) C75 Flange 4" 600lb RJF, ANSI B16.5/316L D44
Flange 6" 150lb RF, ANSI B16.5/316L D45
Flange 2" 150lb RF, ANSI B16.5/PFA1) C76
Flange 2" 150lb RF, ANSI B16.5/Enamelled2) C77 Flange 6" 150lb RF, ANSI B16.5/Hastelloy D46
C4(2.4610)
Flange 2" 150lb FF, ANSI B16.5/316L C78
Flange 6" 150lb RF, ANSI B16.5/ECTFE1) D47
Flange 2" 150lb FF, ANSI B16.5/ECTF1) C80 Flange 6" 150lb RF, ANSI B16.5/PFA1) D48
Flange 2" 150lb SG (small groove), ANSI C81
B16.5/316L Flange 6" 150lb RJF, ANSI B16.5/316L D50
Flange 2" 300lb RF, ANSI B16.5/316L C82 Flange 6" 300lb RF, ANSI B16.5/316L D51
Flange 8" 150lb RF, ANSI B16.5/316L D52
Flange 2" 300lb RF, ANSI B16.5/Hastelloy C83
C4(2.4610) Flange 8" 150lb RF, ANSI B16.5/ECTFE1) D53
Flange 2" 300lb RF, ANSI B16.5/Hastelloy C4(mas- C84 Flange 1" BS.10 Table E/316L D54
sive) Flange 1" BS.10 Table E/PFA1) D55
Flange 2" 300lb RF, ANSI B16.5/ECTFE1) C85 Flange 1½" BS.10 Table E/316L D56
Flange 2" 300lb RF, ANSI B16.5/PFA1) C86 Flange 3½" BS.10 Table E/316L D57
Flange 2" 300lb RF, ANSI B16.5 Enamelled2) C87 Flange 4" BS.10 Table E/ECTFE1) D58
Flange 2" 300lb RJF, ANSI B16.5/316L C88
Flange DN40 10K, JIS/316L D60
Flange 2" 300lb ST, ANSI B16.5/316L D00 Flange DN50 10K, JIS/316L D61
Flange 2" 300lb LG (large groove), ANSI D01 Flange DN80 10K, JIS/316L D62
B16.5/316L
Flange 2" 300lb LT, ANSI B16.5/316L D02 Flange DN100 10K, JIS/316L D63
Flange 2" 600lb RF, ANSI B16.5/316L D03 Adapter/Process temperature
Flange 2" 600lb RF, ANSI B16.5/Monel ZB2977 D04 Without adapter/-50 to 150 °C 1
Flange 2" 600lb RF, ANSI B16.5/ECTFE1) D05 With adapter/-50 to 200 °C3) 2
With adapter/-50...250 °C 3
Flange 2" 600lb RJF, ANSI B16.5/316L D06
Flange 2" 600lb LG, ANSI B16.5/316L D07 With gas-tight leadthrough/-50...150 °C 4
Flange 2" 900lb RJF, ANSI B16.5/316L D08 With gas-tight leadthrough/-50...250 °C 5

Flange 2½" 150lb RF, ANSI B16.5/316L D10 Housing/ Cable entry
Flange 2½" 300lb RF, ANSI B16.5/316L D11 Aluminium IP66/IP67/M20x1.5 A
Aluminium IP66/IP67/½" NPT B

March 2009 Siemens FI 01 · 2009 US Edition 5/73


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVL200, Standard 7ML 5 7 4 6 - SITRANS LVL200, Rigid extension 7ML 5 7 4 7 -
Compact vibrating level switch for use in liquid Compact vibrating level switch for use in liquid
7 7 7 77 - 77 A 0 7 7 7 77 - 77 7 7
applications such as overflow, high, low and applications such as overflow, high, low and
demand applications, as well as pump protection. demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications. For use in SIL-2 and hazardous applications.
Further designs Order code Electronics
Please add "-Z" to Order No. and specify Order Double relay (DPDT) 20 to 72 V DC/20 to 250 V AC 2
code(s). Approvals
Cleaning including Certificate (oil, grease and sili- W01 Without approvals A
cone free) B
Overfill protection (WHG)
Identification Label (measurement loop) SS Y17
Identification Label (measurement loop) Foil Y18 Shipping approvals K
SIL/IEC61508 Certificate of conformity (SIL-2 min. C20 FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP) P
and max. detection) Class II, III, Div. 1, Groups E, F, G
Additional instruction manual Order No. FM (NI) Class I, Div. 2, Groups A, B, C, D Q
LVL200 (DPDT Relay), English 7ML1998-5KR01 Process connection
LVL200 (DPDT Relay), French 7ML1998-5KR11 Thread G¾" A, PN64/316L A00
LVL200 (DPDT Relay), Spanish 7ML1998-5KR21 Thread G¾" A, PN64/316L Ra<0.8µm A01
LVL200 (DPDT Relay), German 7ML1998-5KR31 Thread ¾" NPT, PN64/316L A02
Electronics module LVL200 Relay, English 7ML1998-5LS01 Thread ¾" NPT, PN64/316L Ra<0.8µm A03
Electronics module LVL200 Relay, French 7ML1998-5LS11 Thread ¾" NPT, PN64/Monel A04
Electronics module LVL200 Relay, Spanish 7ML1998-5LS21 Thread G¾" A, PN64/Hastelloy C4 (2.4610) A05

5
Electronics module LVL200 Relay, German 7ML1998-5LS31
Thread ¾" NPT, PN64/Hastelloy C4 (2.4610) A06
This device is shipped with the Siemens Milltronics Thread G1" A, PN64/316L A07
manual CD containing the complete ATEX Quick Thread G1" A, PN64/316L ECTFE coated MB19821) A08
Start and instruction manual library.
Thread G1" A, PN64/316L PFA coated1) A10
Spare Parts Order No.
Thread G1" A, PN64/Monel A11
Electronics module SITRANS LVL200 Relay 7ML1830-1NC
Thread G1" A, PN16/316L A12
1) Available with Adapter/Process temperature options 1 and 4 only
2)
Thread G1" A, PN64/316L Ra<0.8µm A13
Available with Adapter/Process temperature options 1, 2, and 4 only Thread 1" NPT, PN64/316L A14
3)
Available with enamelled Process connection options only
Thread 1" NPT, PN64/316L ECTFE coated A15
MB19821)
Thread 1" NPT, PN64/316L PFA coated1) A16
Thread 1" NPT, PN64/Monel A17
Thread 1" NPT, PN64/316L Ra<0.8µm A18
Thread G1" A, PN64/Hastelloy C4(2.4610) A20
Thread G1½" A, PN64/316L A21
Thread G1½" A, PN64/316L Ra<0,8µm A22
Thread G1½" A, PN64/Hastelloy C4(2.4610) A23
Thread 1" NPT, PN64/Hastelloy C4(2.4610) A24
Thread 1½" NPT, PN64/316L A25
Thread 1½" NPT, PN64/316L Ra<0,8µm A26
Thread 1½" NPT, PN64/Hastelloy C4(2.4610). A27
Thread G2" A, PN64/316L A28
Thread M27x1.5 PN64/316L A30
Cyl. socket/316Ti/1.4581 ECTFE coated ZB29841) A31
Conus DN25 PN40/316L Ra<0.3µm A32
Conus DN25 PN40/316L Ra<0.8µm. A33
Conus DN25 PN40/ECTFE (ZB3033)1) A34
Conus M52 PN40/316L A35
Conus M52 PN40/316L Ra<0.3µm A36
Conus M52 PN40/316L Ra<0.8µm A37
Tri-Clamp 1" PN16/316L Ra<0.3µm A38
Tri-Clamp 1" PN16/Hastelloy C4(2.4610) Ra<0.8µm A40
Tri-Clamp 1" PN16/316L Ra<0.8µm A41
Tri-Clamp 1½" PN16/316L Ra<0.3µm A42
Tri-Clamp 1½" PN16/Hastelloy C4(2.4610) A43
Ra<0.8µm
Tri-Clamp 1½" PN16/316L Ra<0.8µm A44
Tri-Clamp 2" PN16/316L Ra<0.3µm A45
Tri-Clamp 2" PN16/Hastelloy C4(2.4610) Ra<0.8µm A46
Tri-Clamp 2" PN16/316L Ra<0.8µm A47
Tri-Clamp 2½" PN10/316L Ra<0.3µm A48
Tri-Clamp 2½" PN10/316L Ra<0.8µm A50

5/74 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVL200, Rigid extension 7ML 5 7 4 7 - SITRANS LVL200, Rigid extension 7ML 5 7 4 7 -
Compact vibrating level switch for use in liquid Compact vibrating level switch for use in liquid
7 7 7 77 - 77 7 7 7 7 7 77 - 77 7 7
applications such as overflow, high, low and applications such as overflow, high, low and
demand applications, as well as pump protection. demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications. For use in SIL-2 and hazardous applications.
Tri-Clamp 3" PN10/316L Ra<0.3µm A51 Flange DN40 PN40 Form N, DIN 2501/316L B21
Tri-Clamp 3" PN10/316L Ra<0.8µm A52 Flange DN40 PN40 Form E, DIN 2501/316L B22
Bolting DN32 PN40 DIN11851/316L Ra<0.3µm A53 Flange DN40 PN40 V13, DIN 2501/316L B23

Bolting DN32 PN40 DIN11851/316L Ra<0.8µm A54 Flange DN50 PN40 Form C, DIN 2501/316L B24
Bolting DN25 PN40 DIN11851/316L Ra<0.3µm A55 Flange DN50 PN40 Form C, DIN 2501/Hastelloy B25
C4(2.4610)
Bolting DN25 PN40 DIN11851/316L Ra<0.8µm A56 Flange DN50 PN40 Form C, DIN 2501/ECTFE1) B26
Bolting DN40 PN40 DIN11851/316L Ra<0.3µm A57 Flange DN50 PN40 Form C, DIN 2501/ECTFE1) B27
Bolting DN40 PN40 DIN11851/316L Ra<0.8µm A58 (ZB3108)
Bolting DN40 PN40 DIN11864-1 A/316L Ra<0.8µm A60 Flange DN50 PN40 Form C, DIN 2501/PFA1) B28
ZB3052 Flange DN50 PN40 Form D, DIN 2501/316L B30
Bolting DN50 PN25 DIN11851/316L Ra<0.3µm A61 Flange DN50 PN40 Form D, DIN 2501/Hastelloy B31
Bolting DN50 PN25 DIN11851/316L Ra<0.8µm A62 C4(2.4610)
Bolting DN50 PN25 DIN11864-1 A/316L Ra<0.8µm A63 Flange DN50 PN40 Form F, DIN 2501/316L B32
ZB3052 Flange DN50 PN40 Form N, DIN 2501/316L B33
Hygienic w.compr.nut F40 PN25/316L A64 Flange DN50 PN40 Form N, DIN 2501/Hastelloy B34
Hygienic w.compr.nut F40 PN25/316L Ra<0.3µm A65 C4(2.4610)
Flange DN50 PN40 Form E, DIN 2501/316L
5
Hygienic w.compr.nut F40 PN25/316L Ra<0.8µm A66 B35
Flange DN50 PN40 V13, DIN 2501/316L B36
Varivent N50-40/316L Ra<0.3µm A67
Flange DN50 PN40 R13, DIN 2501/316L B37
Varivent N50-40/316L Ra<0.8µm A68
Varivent N125/100/316L Ra<0.8µm A70 Flange DN50 PN64 Form F, DIN 2501/316L B38
Flange DN50 PN64 Form N, DIN 2501/Hastelloy B40
DRD flange PN40/316L ZB3007 A71 C4(2.4610)
SMS DN38/316L Ra<0.8µm1) A72 Flange DN50 PN64 Form C, DIN 2501/316L B41
SMS DN51 PN6/316L Ra<0.8µm1) A73
Flange DN50 PN64 Form L, DIN 2501/316L B42
Swagelok VCR screwing ZG2579 PN64/316L A74 Flange DN50 PN100 Form E, DIN 2501/316L B43
Neumo biocontrol Gr.25 PN16/316L Ra<0.8µm A75 Flange DN50 PN100 Form L, DIN 2501/316L B44
Neumo biocontrol Gr.50 PN16/316L Ra<0.8µm A76
Flange DN65 PN40 Form C, DIN 2501/316L B45
Neumo biocontrol Gr.65 PN16/316L Ra<0.8µm A77 Flange DN65 PN40 Form C, DIN 2501/Hastelloy B46
Neumo biocontrol Gr.80 PN16/316L Ra<0.8µm A78 C4(2.4610)
SÜDMO DN50 PN10/316L/316L Ra<0,8µm A80 Flange DN65 PN40 Form C, DIN 2501/ECTFE1) B47
Small flange DN25 PN1.5 DIN 28403/316L 1)
A81 Flange DN65 PN40 Form C, DIN 2501/PFA B48
pol.Ra<0.8µm Flange DN65 PN40 Form F, DIN 2501/316L B50
Small flange DN40 PN1.5 DIN 28403/316L A82 Flange DN65 PN64 Form E, DIN 2501/316L B51
pol.Ra<0.8µm
Flange DN80 PN40 Form C, DIN 2501/316L B52
Ingold connection PN16/316L Ra<0.8µm A83
Flange DN80 PN40 Form C, DIN 2501/Hastelloy B53
~~Bundklemmst.DN33,7 P A84 C4(2.4610)
~~Aseptik-Bundfl. DN50 A85 Flange DN80 PN40 Form C, DIN 2501/ECTFE1) B54
Flange DN25 PN6 Form C, DIN 2501/316L A86 Flange DN80 PN40 Form C, DIN 2501/PFA1) B55
Flange DN25 PN6 Form C, DIN 2501/PFA1) A87 Flange DN80 PN40 Form F, DIN 2501/316L B56
Flange DN25 PN40 Form C, DIN 2501/316L A88 Flange DN80 PN40 Form N, DIN 2501/316L B57
Flange DN25 PN40 Form C, DIN 2501/Hastelloy B00 Flange DN80 PN40 Form N, DIN 2501/Hastelloy B58
C4(2.4610) C4(2.4610)
Flange DN25 PN40 Form C, DIN 2501/ECTFE1) B01 Flange DN100 PN16 Form C, DIN 2501/316L B60
Flange DN25 PN40 Form C, DIN 2501/PFA1) B02 Flange DN100 PN16 Form C, DIN 2501/Hastelloy B61
Flange DN25 PN40 Form D, DIN 2501/316L B03 C4(2.4610)
Flange DN25 PN40 Form F, DIN 2501/316L B04 Flange DN100 PN16 Form C, DIN 2501/ECTFE1) B62
Flange DN25 PN40 Form N, DIN 2501/316L B05 Flange DN100 PN16 Form C, DIN 2501/PFA1) B63
Flange DN25 PN40 Form N, DIN 2501/Hastelloy C4 B06 Flange DN100 PN16 Form D, DIN 2501/316L B64
solid Flange DN100 PN16 Form F, DIN 2501/316L B65
Flange DN25 PN40 Form N, DIN 2501/Monel solid B07 Flange DN100 PN16 Form N, DIN 2501/316L B66
Flange DN25 PN40 V13, DIN 2501/316L B18 Flange DN100 PN40 Form C, DIN 2501/316L B67
Flange DN32 PN40 Form C, DIN 2501/316L B10 Flange DN100 PN40 Form C, DIN 2501/ECTFE1) B68
Flange DN32 PN40 Form C, DIN 2501/ECTFE1) B11 Flange DN100 PN40 Form C, DIN 2501/PFA1) B70
Flange DN40 PN6 Form C, DIN 2501/316L B12 Flange DN100 PN40 Form C, DIN B71
2501/Enamelled2)
Flange DN40 PN6 Form C, DIN 2501/ECTFE1) B13
Flange DN40 PN40 Form C, DIN 2501/316L B14 Flange DN100 PN40 Form F, DIN 2501/316L B72
Flange DN40 PN40 Form C, DIN 2501/Hastelloy B15 Flange DN100 PN40 Form N, DIN 2501/316L B73
C4(2.4610) Flange DN100 PN40 V13, DIN 2501/316L B74
Flange DN40 PN40 Form C, DIN 2501/ECTFE1) B16 Flange DN100 PN64 Form E, DIN 2501/316L B75
Flange DN40 PN40 Form C, DIN 2501/PFA1) B17 Flange DN100 PN100 Form E, DIN 2501/316L B76
Flange DN40 PN40 Form C, DIN 2501/Enamelled2) B18 Flange DN100 PN100 Form L, DIN 2501/316L B77
Flange DN40 PN40 Form F, DIN 2501/316L B20

March 2009 Siemens FI 01 · 2009 US Edition 5/75


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVL200, Rigid extension 7ML 5 7 4 7 - SITRANS LVL200, Rigid extension 7ML 5 7 4 7 -
Compact vibrating level switch for use in liquid Compact vibrating level switch for use in liquid
7 7 7 77 - 77 7 7 7 7 7 77 - 77 7 7
applications such as overflow, high, low and applications such as overflow, high, low and
demand applications, as well as pump protection. demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications. For use in SIL-2 and hazardous applications.
Flange DN125 PN16 Form F, DIN 2501/316L B78 Flange DN150 PN40 Form B1, EN 1092-1/316L C44
Flange DN125 PN40 Form C, DIN 2501/316L B80 Flange DN150 PN40 Form B1, EN 1092-1/ECTFE1) C45
Flange DN125 PN40 Form N, DIN 2512/316L B81 Flange DN150 PN40 Form B2, EN 1092-1/316L C46
Flange DN150 PN16 Form C, DIN 2501/316L B82 Flange 1" 150lb ANSI B16.5/316L C47
Flange DN150 PN16 Form C, DIN 2501/Hastelloy B83 Flange 1"150lb RF, ANSI B16.5/Hastelloy C48
C4(2.4610) C4(2.4610)
Flange DN150 PN16 Form C, DIN 2501/ECTFE1) B84 Flange 1"150lb RF, ANSI B16.5//Monel ZB2977 C50
Flange DN150 PN16 Form C, DIN 2501/PFA1) B85 Flange 1" 150lb RF, ANSI B16.5/ECTFE1) C51
Flange DN150 PN16 Form D, DIN 2501/316L B86 Flange 1"150lb RF, ANSI B16.5/PFA1) C52
Flange DN150 PN40 Form C, DIN 2501/316L B87 Flange 1" 150lb RF, ANSI B16.5/Enamelled2) C53
Flange DN150 PN40 Form C, DIN 2501/Hastelloy B88 Flange 1" 300lb RF, ANSI B16.5/316L C54
C4(2.4610) Flange 1" 300lb RF, ANSI B16.5/ECTFE1) C55
Flange DN150 PN40 Form F, DIN 2501/316L C00
Flange 1" 600lb RF, ANSI B16.5/316L C56
Flange DN150 PN40 Form N, DIN 2512/316L C01
Flange 1½" 150lb RF, ANSI B16.5/316L C57
Flange DN200 PN10 Form C, DIN 2501/ECTFE1) C02 Flange 1½" 150lb RF, ANSI B16.5/Hastelloy C58
Flange DN200 PN16 Form C, DIN 2501/316L C03 C4(2.4610)
Flange DN25 PN40 Form B1, EN 1092-1/316L C04 Flange 1½" 150lb RF, ANSI B16.5/ECTFE1) C60
5 Flange DN25 PN40 Form B1, EN 1092-1/Hastelloy
C4(2.4610)
C05 Flange 1½" 150lb RF, ANSI B16.5/PFA1)
Flange 1½" 150lb RF, ANSI B16.5 Enamelled2)
C61
C62
Flange DN25 PN40 Form B1, EN/316L/PFA1) C06
Flange 1½" 150lb FF, ANSI B16.5/ECTFE1) C63
Flange DN25 PN40 Form B1, EN 1092- C07
Flange 1½" 300lb RF, ANSI B16.5/316L C64
1/Enamelled2)
Flange 1½" 300lb RF, ANSI B16.5//Monel ZB2977 C65
Flange DN25 PN40 Form B2, EN 1092-1/316L C18
Flange 1½" 300lb RF, ANSI B16.5/ECTFE1) C66
Flange DN25 PN40 Form F, EN 1092-1/316L C10 Flange 1½" 600lb RF, ANSI B16.5/316L C67
Flange DN25 PN63 Form B1, EN 1092-1/316L C11 Flange 2" 150lb RF, ANSI B16.5/316L C68
Flange DN25 PN100 Form B2, EN 1092-1/316L C12
Flange 2" 150lb RF, ANSI B16.5/Hastelloy C70
Flange DN40 PN40 Form B1, EN/316L C13 C4(2.4610)
Flange DN40 PN40 Form B1, EN 1092-1/PFA1) C14 Flange 2" 150lb RF, ANSI B16.5//Monel ZB2977 C71
Flange DN40 PN40 Form B2, EN/316L C15 Flange 2" 150lb RF, ANSI B16.5/ECTFE1) C72
Flange DN50 PN40 Form B1, EN/316L C16 Flange 2" 150lb RF, ANSI B16.5/PFA1) C73
Flange DN50 PN40 Form B1, EN 1092-1/Hastelloy C17 Flange 2" 150lb RF, ANSI B16.5/Enamelled2) C74
C4(2.4610) Flange 2" 150lb FF, ANSI B16.5/316L C75
Flange DN50 PN40 Form B1,EN 1092-1/Monel C18
ZB2977 Flange 2" 150lb FF, ANSI B16.5/ECTFE1) C76
1) Flange 2" 150lb SG (small groove), ANSI C77
Flange DN50 PN40 Form B1, EN 1092-1/ECTFE C20 B16.5/316L
Flange DN50 PN40 Form B1, EN/316L/PFA1) C21 Flange 2" 300lb RF, ANSI B16.5/316L C78
Flange DN50 PN40 Form B1, EN 1092- C22
1/Enamelled2) Flange 2" 300lb RF, ANSI B16.5/Hastelloy C80
C4(2.4610)
Flange DN50 PN40 Form C, EN 1092-1/316L C23 Flange 2" 300lb RF, ANSI B16.5/Hastelloy C4(mas- C81
Flange DN50 PN40 Form D, EN/316L C24 sive)
Flange DN50 PN40 Form D, EN 1092-1/Hastelloy C25 Flange 2" 300lb RF, ANSI B16.5/ECTFE1) C82
C4(2.4610)
Flange 2" 300lb RF, ANSI B16.5/PFA1) C83
Flange DN50 PN40 Form B2, EN 1092-1/316L C26 Flange 2" 300lb RF, ANSI B16.5 Enamelled2) C84
Flange DN50 PN40 Form E, EN 1092-1/316L C27 Flange 2" 300lb RJF, ANSI B16.5/316L C85
Flange DN80 PN40 Form B1, EN 1092-1/316L C28
Flange 2" 300lb ST, ANSI B16.5/316L C86
Flange DN80 PN40 Form B1, EN 1092-1/Hastelloy C30 Flange 2" 300lb LG (large groove), ANSI C87
C4(2.4610) B16.5/316L
Flange DN80 PN40 Form B1, EN 1092-1/ECTFE1) C31 Flange 2" 300lb LT, ANSI B16.5/316L C88
Flange DN80 PN40 Form B1, EN 1092- C32
1/Enamelled2) Flange 2" 600lb RF, ANSI B16.5/316L D00
Flange 2" 600lb RF, ANSI B16.5/Monel ZB2977 D01
Flange DN80 PN40 Form B2, EN 1092-1/316L C33
Flange 2" 600lb RF, ANSI B16.5/ECTFE1) D02
Flange DN100 PN16 Form B1, EN 1092-1/316L C34
Flange DN100 PN16 Form B1, EN 1092-1/Hastelloy C35 Flange 2" 600lb RJF, ANSI B16.5/316L D03
C4(2.4610) Flange 2" 600lb LG, ANSI B16.5/316L D04
Flange DN100 PN16 Form B1, EN 1092- C36 Flange 2" 900lb RJF, ANSI B16.5/316L D05
1/Enamelled2) Flange 2½" 150lb RF, ANSI B16.5/316L D06
Flange DN100 PN40 Form B1, EN 1092-1/316L C37 Flange 2½" 300lb RF, ANSI B16.5/316L D07
Flange DN100 PN40 Form B1, EN 1092- C38 Flange 3" 150lb RF, ANSI B16.5/316L D18
1/Enamelled2)
Flange 3" 150lb RF, ANSI B16.5/Hastelloy D10
Flange DN100 PN40 Form C, EN 1092-1/316L C40 C4(2.4610)
Flange DN100 PN63 Form B2, EN 1092-1/316L C41 Flange 3" 150lb RF, ANSI B16.5//Monel ZB2977 D11
Flange DN150 PN16 Form B1, EN 1092-1/316L C42 Flange 3" 150lb RF, ANSI B16.5/ECTFE1) D12
Flange DN150 PN16 Form B1, EN 1092-1/PFA1) C43 Flange 3" 150lb RF, ANSI B16.5/PFA1) D13

5/76 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVL200, Rigid extension 7ML 5 7 4 7 - SITRANS LVL200, Rigid extension 7ML 5 7 4 7 -
Compact vibrating level switch for use in liquid Compact vibrating level switch for use in liquid
7 7 7 77 - 77 7 7 7 7 7 77 - 77 7 7
applications such as overflow, high, low and applications such as overflow, high, low and
demand applications, as well as pump protection. demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications. For use in SIL-2 and hazardous applications.
Flange 3" 150lb RF, ANSI B16.5/Enamelled2) D14 Rigid Extension 316L
Flange 3" 150lb FF, ANSI B16.5/316L D15 80 to 500 mm A0
Flange 3" 150lb FF, ANSI B16.5/ECTFE1) D16 501 to 1000 mm A1
Flange 3" 150lb FF, ANSI B16.5/PFA1) D17 1001 to 1500 mm A2
Flange 3" 300lb RF, ANSI B16.5/316L D18 1501 to 2000 mm A3
Flange 3" 300lb RF, ANSI B16.5/Hastelloy D20 2001 to 2500 mm A4
C4(2.4610)
2501 to 3000 mm A5
Flange 3" 300lb RF, ANSI B16.5/ECTFE1) D21
Flange 3" 300lb RF, ANSI B16.5/PFA1) D22 3001 to 3500 mm A6
3501 to 4000 mm A7
Flange 3" 300lb RF, ANSI B16.5/Enamelled2) D23
Flange 3" 600lb RF, ANSI B16.5/316L D24 Rigid Extension ECTFE coated1)
Flange 3½" 150lb RF, ANSI B16.5/316L D25 80 to 500 mm B0
501 to 1000 mm B1
Flange 3½" 150lb RF, ANSI B16.5/ECTFE1) D26
1001 to 1500 mm B2
Flange 4" 150lb RF, ANSI B16.5/316L D27
Flange 4" 150lb RF, ANSI B16.5/Hastelloy D28 1501 to 2000 mm B3
C4(2.4610) 2001 to 2500 mm B4
2501 to 3000 mm B5
Flange 4" 150lb RF, ANSI B16.5/ECTFE1) D30
Flange 4" 150lb RF, ANSI B16.5/PFA1)
Flange 4" 150lb RF, ANSI B16.5/Enamelled2)
D31
D32
3001 to 3500 mm
3501 to 4000 mm
B6
B7 5
Flange 4" 150lb LT, ANSI B16.5/316L D33 Rigid Extension PFA coated1)
Flange 4" 300lb RF, ANSI B16.5/316L D34 80 to 500 mm C0
Flange 4" 300lb RF, ANSI B16.5/Hastelloy D35 501 to 1000 mm C1
C4(2.4610) 1001 to 1500 mm C2
Flange 4" 300lb RF, ANSI B16.5/ECTFE1) D36 1501 to 2000 mm C3
Flange 4" 300lb RJF, ANSI B16.5/316L D37 2001 to 2500 mm C4
Flange 4" 300lb LG, ANSI B16.5/316L D38 2501 to 3000 mm C5
Flange 4" 300lb LT, ANSI B16.5/316L D40 3001 to 3500 mm C6
Flange 4" 600lb RF, ANSI B16.5/316L D41 3501 to 4000 mm C7
Flange 4" 600lb RJF, ANSI B16.5/316L D42 Rigid Extension 316L Ra ≤ 0.8μm
Flange 5" 150lb RF, ANSI B16.5/316L D43 80 to 500 mm D0
Flange 6" 150lb RF, ANSI B16.5/316L D44 501 to 1000 mm D1
Flange 6" 150lb RF, ANSI B16.5/Hastelloy D45 1001 to 1500 mm D2
C4(2.4610)
1501 to 2000 mm D3
Flange 6" 150lb RF, ANSI B16.5/ECTFE1) D46 2001 to 2500 mm D4
Flange 6" 150lb RF, ANSI B16.5/PFA1) D47 2501 to 3000 mm D5
Flange 6" 150lb RJF, ANSI B16.5/316L D48
3001 to 3500 mm D6
Flange 6" 300lb RF, ANSI B16.5/316L D50 3501 to 4000 mm D7
Flange 8" 150lb RF, ANSI B16.5/316L D51
Rigid Extension 316L Ra ≤ 0.3μm
Flange 8" 150lb RF, ANSI B16.5/ECTFE1) D52
80 to 500 mm E0
Flange 1" BS.10 Table E/316L D53 501 to 1000 mm E1
Flange 1" BS.10 Table E/PFA1) D54 1001 to 1500 mm E2
Flange 1½" BS.10 Table E/316L D55
1501 to 2000 mm E3
Flange 3½" BS.10 Table E/316L D56 2001 to 2500 mm E4
Flange 4" BS.10 Table E/ECTFE1) D57 2501 to 3000 mm E5
Flange DN40 10K, JIS/316L D58
3001 to 3500 mm E6
Flange DN50 10K, JIS/316L D60 3501 to 4000 mm E7
Flange DN80 10K, JIS/316L D61
Rigid Extension Enamelled version2)
Flange DN100 10K, JIS/316L D62
80 to 250 mm F0
Adapter/Process temperature 251 to 500 mm F1
Without adapter/-50 to 150 °C 1 501 to 750 mm F2
With adapter/-50 to 200 °C3) 2
751 to 1000 mm F3
With adapter/-50...250 °C 3
1001 to 1250 mm F4
With gas-tight leadthrough/-50...150 °C 4 1251 to 1500 mm F5
With gas-tight leadthrough/-50...250 °C 5
Housing/ Cable entry
Aluminium IP66/IP67/M20x1.5 A
Aluminium IP66/IP67/½" NPT B

March 2009 Siemens FI 01 · 2009 US Edition 5/77


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

Selection and Ordering data Order No.


SITRANS LVL200, Rigid extension 7ML 5 7 4 7 -
Compact vibrating level switch for use in liquid
7 7 7 77 - 77 7 7
applications such as overflow, high, low and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
Further designs Order code
Please add "-Z" to Order No. and specify Order
code(s).
Enter the total insertion length in plain text descrip- Y01
tion, max. 4000 mm (157.48”)
Cleaning including Certificate (oil, grease and sili- W01
cone free)
Identification Label (measurement loop) SS Y17
Identification Label (measurement loop) Foil Y18
SIL/IEC61508 Certificate of conformity (SIL-2 min. C20
and max. detection)
Additional instruction manual Order No.
LVL200 Extended (DPDT Relay), English 7ML1998-5KW01
LVL200 Extended (DPDT Relay), French 7ML1998-5KW11
LVL200 Extended (DPDT Relay), Spanish 7ML1998-5KW21
LVL200 Extended (DPDT Relay), German 7ML1998-5KW31
Electronics module LVL200 Relay, English 7ML1998-5LS01
5 Electronics module LVL200 Relay, French
Electronics module LVL200 Relay, Spanish
7ML1998-5LS11
7ML1998-5LS21
Electronics module LVL200 Relay, German 7ML1998-5LS31
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Spare Parts Order No.
Electronics module SITRANS LVL200 Relay 7ML1830-1NC
Lock fitting, unpressurized, G1A/316L 7ML19301DQ
Lock fitting, unpressurized, 1NPT/316L 7ML19301DR
Lock fitting, unpressurized, G1-1/2A/316L 7ML19301DS
Lock fitting, unpressurized, 1-1/2NPT/316L 7ML19301DT
Lock fitting, -1… 16 bar, G1A/316L 7ML19301DU
Lock fitting, -1… 16 bar, 1NPT/316L 7ML19301DV
Lock fitting, -1… 16 bar, G1-1/2A/316L 7ML19301DW
Lock fitting, -1… 16 bar, 1-1/2NPT/316L 7ML19301DX
Lock fitting, -1… 64 bar, G1A/316L 7ML19301EA
Lock fitting, -1… 64 bar, 1NPT/316L 7ML19301EB
Lock fitting, -1… 64 bar, G1-1/2A/316L 7ML19301EC
Lock fitting, -1… 64 bar, 1-1/2NPT/316L 7ML19301ED
1)
Available with Adapter/Process temperature options 1 and 4 only
2)
Available with Adapter/Process temperature options 1, 2, and 4 only
3) Available with enamelled Process connection and Extension options only

5/78 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

■ Characteristic curves

SITRANS LVL200 Process Pressure/Process Temperature/Ambient Temperature derating curves

March 2009 Siemens FI 01 · 2009 US Edition 5/79


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

■ Dimensional drawings

SITRANS LVL200 (Standard) dimensions

5/80 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

■ Dimensional drawings

SITRANS LVL200 (Extended) dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/81


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVL200

■ Schematics

5 SITRANS LVL200 connections

5/82 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Vibrating point level switch
Input
Measured variable High, low and demand
Measuring frequency
• Standard 125 Hz
• Liquid/solid interface version 350 Hz
Output
• PNP Open collector:
Permanent load max. 0.4 A, short-
circuit and overload protected
Turn-on voltage: max. 50 V
(reverse protection)
• 2-wire without contact Load current:
• min. 10 mA
SITRANS LVS200 is a vibrating point level switch for high or low • max. 500 mA permanent
levels of bulk solids. • max. 2A < 200 ms
• max. 5A < 50 ms
■ Benefits Voltage drop on the electronic
5
module: max. 7 V with closed
• High resistance to mechanical forces electric circuit
• Strong vibration resistance to high bulk material loads Cutoff current with open electric
• Rotatable enclosure circuit: max. 5 mA
• Suitable for low density material: standard version, 20 g/l • Relays
(1.3 lb/ft3); liquid/solid interface version, 50 g/l (3 lb/ft3), and - Version with 1 relay SPDT relay
low density option min. 5 g/l (0.3 lb/ft3)
- Version with 2 relays DPDT relay
• Customer desired extensions up to 20000 mm (787")
• Relay delay • From loss of vibration: approxi-
• Optional detection of solids within liquid mately 1 second
• Durable short fork option with 165 mm (6.5") insertion length • From resumption of vibration:
approximately 1 to 2 seconds
■ Application • Signal delay • Probe uncovered to covered:
approximately 1 second
The standard LVS200 detects high, low or demand levels of dry
• Probe covered to uncovered:
bulk solids in bins, silos or hoppers. The liquid/solid interface approximately 1 to 2 seconds
version can also detect settled solids within liquids or solids
within confined spaces such as feed pipes. It is designed to ig- • Relay fail-safe High or low, switch selectable
nore liquids in order to detect the interface between a solid and • Alarm output • Relay 8 A at 250 V AC, non-in-
a liquid. ductive
A pipe extension version is available with either the standard or • Relay 5 A at 30 V DC, non-induc-
liquid/solid interface electronics and fork, separated by a cus- tive
tomer supplied 1" pipe. • mA output 8/16 mA or 4 to 20 mA
SITRANS LVS200 has an optional 4 to 20 mA output for monitor- - Resolution 4 to 20 mA ± 0.1 mA
ing buildup on the fork to determine when preventative mainte- Sensitivity High or low, switch selectable
nance should be performed in sticky applications.
Rated operating conditions
The LVS200 has a compact design and can be top, side or angle
Installation conditions
mounted. The vibrating fork design ensures the tines are kept
clean. The unique design of the fork and crystal assembly elim- • Location Indoor/outdoor
inates false high level readings even if tines become damaged. Ambient conditions
A signal from the electronic circuit excites a crystal in the probe • Ambient temperature -40 to +60 °C (-40 to +140 °F)
causing the fork to vibrate. If the fork is covered by material, the
change in vibration is detected by the electronic circuitry which • Installation catagory III
causes the relay to change state after a one second delay. When • Pollution degree 2
the fork is free from material pressure, full vibration resumes and
the relay reverts to its normal condition.
• Key Applications: dry bulk solids in bins, silos, hoppers or set-
tled solids within liquids (interface version)

March 2009 Siemens FI 01 · 2009 US Edition 5/83


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200
Medium conditions
• Process temperature • All except CSA Class II, Group
G: -40 to +150 °C
(-40 to +302 °F)
• CSA Class II, Group G: -40 to
+140 °C (-40 to +284 °F), CSA
temperature code T3B
• Max. threaded bushing tempera- +80 °C (+176 °F)
ture
• Max. enclosure surface tempera- +90 °C (+194 °F)
ture (Category 2D)
• Max. extension surface tempera- +150 °C (+302 °F)
ture (Category 1D)
• Pressure (vessel) Max. 10 bar (145 psi) European
Pressure Directive 97/23/EC:
Category 1
• Minimum material density • Standard version: approx. 20 g/l
(1.2 lb/ft3)
• liquid/solid interface version: ap-
prox. 50 g/l (3 lb/ft3)
• optional low density version: ap-
prox. 5 g/l (0.3 lb/ft3)
Design
5 • Material
- Enclosure Epoxy coated aluminum
• Process connection • Thread 1½" NPT [(Taper), AN-
SI/ASME B1.20.1], R ½" [(BSPT),
EN 10226] and flange options
• Optional sliding bushing with
2" NPT [(Taper), ANSI/ASME
B1.20.1] or BSP thread
• Thread material: stainless steel
303 (1.4301)
• Tine material Stainless steel 316TI (1.4571),
PTFE-coated tines are available
upon special request
• Degree of protection IP65/Type 4/NEMA 4
• Conduit entry 2 x M20x1.5 or 2 x ½" NPT
• Weight • Standard version, no exten-
sions: approx 2.0 kg (4.4 lbs)
• Solids/liquids version, no exten-
sions: approx. 1.9 kg (4.2 lbs)
Power supply • 19 to 230 V AC, +10%,
50 to 60 Hz, 8 VA
• 19 to 55 V DC, +10%, 1.5 W
Certificates and approvals
• CSA/FM General Purpose
• CE
• CSA/FM Dust Ignition Proof
• C-TICK
• ATEX II 1/2 D
• CSA/FM IS Class I, II, III Div. 1,
Groups A, B, C, D, E, F, G, FM
Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, available only with
power supply option 5 and 6
• ATEX II 1G and 1/2 G Eex ia IIC;
ATEX II 1D and 1/2 D, available
only with power supply option 5

5/84 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVS200, standard 7ML 5 7 3 1 - SITRANS LVS200, standard 7ML 5 7 3 1 -
Vibrating point level switch for high or low levels of Vibrating point level switch for high or low levels of
7 7 7 7 7 - 77 A 0 7 7 7 7 7 - 77 A 0
bulk solids bulk solids
Power supply Stainless Steel 316TI (1.4571)
19 to 230 V AC, 19 to 55 V DC, one relay output 1 Standard length, 230 mm (9.06")7) 31
(SPDT)
Add order code Y01 and plain text: “Insertion
19 to 230 V AC, 19 to 55 V DC, two relay outputs 2 length ...mm"
(DPDT)
• 300 to 500 mm (11.81 to 19.69")7) 32
18 to 50 V DC PNP 3
• 501 to 750 mm (19.72 to 29.53")7) 33
19 to 230 V AC/DC without contact, 2-wire loop 4 751 to 1000 mm (29.57 to 39.37")7) 34
powered1)
7 to 9 V DC (requires NAMUR switch amplifier) 5 1001 to 1250 mm (39.41 to 49.21")7) 35
NAMUR IEC 60947-5-6, 2-wire2) • 1251 to 1500 mm (49.25 to 59.06")7) 36
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire 6 • 1501 to 1750 mm (59.09 to 68.90")7) 37
19 to 230 V AC, 19 to 55 V DC, one relay output } 7 • 1751 to 2000 mm (68.94 to 78.74")7) 38
(SPDT) basic version3) 4) • 2001 to 2250 mm (78.78 to 88.58")7) 41
Process temperature • 2251 to 2500 mm (88.62 to 98.43")7) 42
Without temperature isolator } A • 2501 to 2750 mm (98.46 to 108.27")7) 43
With temperature isolator B • 2751 to 3000 mm (108.31 to 118.11")7) 44
Separated enclosure - cable length 1.5 m (4.92 ft) C • 3001 to 3250 mm (118.15 to 127.95")7) 45
[max. temperature process +180 °C
(+356 °F)/max. temperature electronics +80 °C • 3251 to 3500 mm (127.99 to 137.80")7) 46
(+176 °F)] • 3501 to 3750 mm (137.83 to 147.64")7) 47
Separated enclosure - cable length 4.0 m (13.12 ft)
[max. temperature process +180 °C
D • 3751 to 4000 mm (147.68 to 157.48")7)
Material process connection/extension
48 5
(+356 °F)/max. temperature electronics +80 °C
(+176 °F)] Stainless steel 304 (1.4301) } 1
Stainless steel 316 TI (1.4571) 2
Process connection
Threaded Approvals
R 1½" [(BSPT), EN 10226] } A CSA/FM Dust Ignition Proof, C-TICK } A
1½" NPT [(Taper), ANSI/ASME B1.20.1] } B ATEX II 1/2 D, C-TICK } B
G 2" [(BSPP), EN ISO 228-1], sliding sleeve [min. C CSA/FM General Purpose, C-TICK C
length 500 mm (19.69")]5) CE, C-TICK D
2" NPT [(Taper), ANSI/ASME B1.20.1] , sliding D CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
sleeve [min. length 500 mm (19.69")]5) E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia
Flanged IIC, C-TICK8)
DN 100 PN 6, EN1092-1 (1.4541/321) E ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
DN 100 PN 16, EN1092-1 (1.4541/321) F 1/2D, C-TICK
2" ASME 150 lbs B16.5 (1.4541/321) G Further designs Order code
3" ASME 150 lbs B16.5 (1.4541/321) H Please add “-Z" to Order No. and specify Order
4" ASME 150 lbs B16.5 (1.4541/321) J code(s).
Extension length Total insertion length: Enter the total insertion length Y01
Stainless steel 304 (1.4301) in plain text description, max. 4000 mm (157.48")
Standard length, 230 mm (9.06")6) } 11 Enhanced sensitivity > 5 g/l via electronics and K05
increased fork length to 195 mm (7.68")
Add order code Y01 and plain text: “Insertion Enhanced sensitivity < 5 g/l via electronics, G01
length ... mm" increased fork length to 195 mm (7.68"), and
• 300 to 500 mm (11.81 to 19.69")6) 12 increased aluminum fork width (available only with
• 501 to 750 mm (19.72 to 29.53")6) 13 universal voltage, SPDT, CE/FM and CSA General
• 751 to 1000 mm (29.57 to 39.37")6) 14 Purpose approvals)
• 1001 to 1250 mm (39.41 to 49.21")6) 15 Signal bulb inserted in M20 cable gland9) A20
• 1251 to 1500 mm (49.25 to 59.06")6) 16 NAMUR 8/16 mA switch amplifiers A15
• 1501 to 1750 mm (59.09 to 68.90")6) 17
Instruction manual Order No.
• 1751 to 2000 mm (68.94 to 78.74")6) 18 Multi-language 7ML1998-5FT62
• 2001 to 2250 mm (78.78 to 88.58")6) 21
This device is shipped with the Siemens Milltronics
• 2251 to 2500 mm (88.62 to 98.43")6) 22 manual CD containing the complete ATEX Quick
• 2501 to 2750 mm (98.46 to 108.27")6) 23 Start and instruction manual library.
• 2751 to 3000 mm (108.31 to 118.11")6) 24 Spare parts
• 3001 to 3250 mm (118.15 to 127.95")6) 25 Replacement Electronics Module (125 Hz) 7ML1830-1KL
• 3251 to 3500 mm (127.99 to 137.80")6) 26 [19 to 230 V AC, 19 to 55 V DC, one relay output
(SPDT)]
• 3501 to 3750 mm (137.83 to 147.64")6) 27
Sliding sleeve, 2" BSP (ISO 228) 7ML1830-1JM
• 3751 to 4000 mm (147.68 to 157.48")6) 28
Sliding sleeve, 2" NPT [(Taper), ANSI/ASME 7ML1830-1JN
B1.20.1]

March 2009 Siemens FI 01 · 2009 US Edition 5/85


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200

Selection and Ordering data Order No.


SITRANS LVS200, standard 7ML 5 7 3 1 -
Vibrating point level switch for high or low levels of
7 7 7 7 7 - 77 A 0
bulk solids
Available ex stock
SITRANS LVS200, standard, power supply 7, pro- 7ML5731-
cess temperature A, process connection A, exten- 7AA11-1BA0
sion length 11, material process
connection/extension 1, and approval B
SITRANS LVS200, standard, power supply 7, pro- 7ML5731-
cess temperature A, process connection B, exten- 7AB11-1AA0
sion length 11, material process
connection/extension 1, and approval A
1)
Available with approval options A to D only
2)
Available with approval options E, F only
3)
Available only with process temperature option A (process connection A
with approval option B, or process connection B with approval option A),
extension length 11 and material process connection 1
4) Basic version is cost effective and offers fast delivery.
5) Not available with extension length options 11 and 12
6)
Available with Material process connection/extension option 1 only
7)
Available with Material process connection/extension option 2 only
8)
Available with power supply option 5 and 6 only
9)
Available with approval options C, D only
} Available ex stock.

5/86 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVS200, short fork for liquids/solids 7ML 5 7 3 2 - SITRANS LVS200, short fork for liquids/solids 7ML 5 7 3 2 -
interface interface
7 7 7 77 - 77 A 0 7 7 7 77 - 77 A 0
Vibrating point level switch for interface applica- Vibrating point level switch for interface applica-
tions, and high load applications with short inser- tions, and high load applications with short inser-
tion requirements tion requirements
Power supply 1001 to 1250 mm (39.41 to 49.21")3) 35
19 to 230 V AC, 19 to 55 V DC, one relay output 1 1251 to 1500 mm (49.25 to 59.06")4) 36
(SPDT)
1501 to 1750 mm (59.09 to 68.90")4) 37
19 to 230 V AC, 19 to 55 V DC, two relay outputs 2
(DPDT) 1751 to 2000 mm (68.94 to 78.74")4) 38
18 to 50 V DC PNP 3 2001 to 2250 mm (78.78 to 88.58")4) 41

19 to 230 V AC/DC without contact, 2-wire loop 4 2251 to 2500 mm (88.62 to 98.43")4) 42
powered1) 2501 to 2750 mm (98.46 to 108.27")3) 43
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire 5 2751 to 3000 mm (108.31 to 118.11")3) 44
Process temperature 3001 to 3250 mm (118.15 to 127.95")3) 45
Without temperature isolator A 3251 to 3500 mm (127.99 to 137.80")3) 46
With temperature isolator B 3501 to 3750 mm (137.83 to 147.64")3) 47
3751 to 4000 mm (147.68 to 157.48")3) 48
Separated enclosure - cable length 1.5 m (4.92 ft) C
[max. temperature process +180 °C Material process connection/extension
(+356 °F)/max. temperature electronics +80 °C Stainless steel 304 (1.4301) 1
(+176 °F)] Stainless steel 316 TI (1.4571) 2
Separated enclosure - cable length 4.0 m (13.12 ft) D
[max. temperature process +180 °C Approvals
(+356 °F)/max. temperature electronics +80 °C
(+176 °F)]
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
A
B
5
Process connection CSA/FM General Purpose, C-TICK C
Threaded CE, C-TICK D
R 1½" [(BSPT), EN 10226] A Further designs Order code
1½" NPT [(Taper), ANSI/ASME B1.20.1] B
Please add “-Z" to Order No. and specify Order
G 2" [(BSPP), EN ISO 228-1], sliding sleeve [min. C code(s).
length 500 mm (19.69")]
2" NPT [(Taper), ANSI/ASME B1.20.1], sliding D Total insertion length: Enter the total insertion length Y01
sleeve [min. length 500 mm (19.69")] in plain text description, max. 4000 mm (157.48")
Flanged Signal bulb inserted in M20 cable gland4) A20
DN 100 PN 6, EN1092-1 (1.4541/321) E
Instruction manual Order No.
DN 100 PN 16, EN1092-1 (1.4541/321) F
Multi-language 7ML1998-5FT62
2" ASME 150 lbs B16.5 (1.4541/321) G
This device is shipped with the Siemens Milltronics
3" ASME 150 lbs B16.5 (1.4541/321) H manual CD containing the complete ATEX Quick
4" ASME 150 lbs B16.5 (1.4541/321) J Start and instruction manual library.
Extension length Spare parts
Stainless steel 304 (1.4301)2) Replacement Electronics Module (350 Hz) 7ML1830-1KM
Standard length, 165 mm (6.50")2) 11 [19 to 230 V AC, 19 to 55 V DC, one relay output
(SPDT)]
Add order code Y01 and plain text: “Insertion
length ... mm" Sliding sleeve, 2" [(BSPP), EN ISO 228-1] 7ML1830-1JM
200 to 500 mm (7.87 to 19.69")2) 12 Sliding sleeve, 2" NPT [(Taper), ANSI/ASME B1.20.1] 7ML1830-1JN
501 to 750 mm (19.72 to 29.53")2) 13 1)
Available with approval options B, C, D only
751 to 1000 mm (29.57 to 39.37")2) 14 2)
Available with material process connection/extension option 1 only
3)
1001 to 1250 mm (39.41 to 49.21")2) 15 Available with material process connection/extension option 2 only
4)
Available with approval options C, D only
1251 to 1500 mm (49.25 to 59.06")2) 16
1501 to 1750 mm (59.09 to 68.90")2) 17
1751 to 2000 mm (68.94 to 78.74")2) 18
2001 to 2250 mm (78.78 to 88.58")2) 21
2251 to 2500 mm (88.62 to 98.43)"2) 22
2501 to 2750 mm (98.46 to 108.27")2) 23
2751 to 3000 mm (108.31 to 118.11")2) 24
3001 to 3250 mm (118.15 to 127.95")2) 25
3251 to 3500 mm (127.99 to 137.80")2) 26
3501 to 3750 mm (137.83 to 147.64")2) 27
3751 to 4000 mm (147.68 to 157.48")2) 28
Stainless Steel 316TI (1.4571)
Standard length, 165 mm (6.50")3) 31
Add order code Y01 and plain text: “Insertion
length ...mm"
200 to 500 mm (7.87 to 19.69") 3) 32
501 to 750 mm (19.72 to 29.53")3) 33
751 to 1000 mm (29.57 to 39.37")3) 34

March 2009 Siemens FI 01 · 2009 US Edition 5/87


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVS200, pipe extension 7ML 5 7 3 3 - SITRANS LVS200, pipe extension 7ML 5 7 3 3 -
Vibrating point level switch for high or low levels of Vibrating point level switch for high or low levels of
7 7 7 77 - 77 A 0 7 7 7 77 - 77 A 0
bulk solids bulk solids
Extended using 1" pipe extension (customer sup- Extended using 1" pipe extension (customer sup-
plied) plied)
Power supply Instruction manual
19 to 230 V AC, 19 to 55 V DC, one relay output 1 Multi-language 7ML1998-5FT62
(SPDT) Note: One instruction manual is shipped with this
19 to 230 V AC, 19 to 55 V DC, two relay outputs 2 product.
(DPDT) This device is shipped with the Siemens Milltronics
18 to 50 V DC PNP 3 manual CD containing the complete ATEX Quick
19 to 230 V AC/DC without contact, 2-wire loop 4 Start and instruction manual library.
powered1) Spare parts
7 to 9 V DC (requires NAMUR switch amplifier) 5 Replacement Electronics Module (125 Hz) 7ML1830-1KL
NAMUR IEC 60947-5-6, 2-wire2) [19 to 230 V AC, 19 to 55 V DC, one relay output
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire 6 (SPDT)]
Process temperature Replacement Electronics Module (350 Hz) 7ML1830-1KM
[19 to 230 V AC, 19 to 55 V DC, one relay output
Up to +150 °C (+302 °F) A (SPDT)]
Process connection 1)
Available with approval options A to D only
Threaded 2)
Available with application type 1 only
R 1½" [(BSPT), EN 10226] 3)
A Available with power supply option 5 only
4)
1½" NPT [(Taper), ANSI/ASME B1.20.1] B Available with approval options C, D only

5 Flanged
DN 100 PN 6, EN1092-1 (1.4541/321) C
DN 100 PN 16, EN1092-1 (1.4541/321) D
2" ASME 150 lbs B16.5 (1.4541/321) E
3" ASME 150 lbs B16.5 (1.4541/321) F
4" ASME 150 lbs B16.5 (1.4541/321) G
Process connection material
Stainless steel 304 (1.4301) 1
Stainless steel 316 TI (1.4571) 2
Extension length
Customer supplied 1" pipe extension 1
Length: 300 to 3800 mm (11.81 to 149.61")
Application type
Dry bulk solids (125 Hz) 1
Liquids/solids interface (350 Hz) 2
Approvals
CSA/FM Dust Ignition Proof, C-TICK A
ATEX II 1/2 D, C-TICK B
CSA/FM General Purpose, C-TICK C
CE, C-TICK D
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia
IIC, C-TICK3)
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
1/2D, C-TICK3)
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Enter the total insertion length in plain text descrip- Y01
tion, min. 300 mm (11.81") max. 3800 mm (149.61")
Enhanced sensitivity > 5 g/l via electronics and K05
increased fork length to 195 mm (7.68")
Signal bulb inserted in M20 cable gland4) A20

NAMUR 8 to 16 mA switch amplifiers A15

5/88 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LVS200, cable extended 7ML 5 7 3 4 - SITRANS LVS200, cable extended 7ML 5 7 3 4 -
Vibrating point level switch for high or low levels of Vibrating point level switch for high or low levels of
7 7 7 7 7 - 77 A 0 7 7 7 7 7 - 77 A 0
bulk solids bulk solids
Power supply Approvals
19 to 230 V AC, 19 to 55 V DC, one relay output 1 CSA/FM Dust Ignition Proof, C-TICK A
(SPDT) ATEX II 1/2 D, C-TICK B
19 to 230 V AC, 19 to 55 V DC, two relay outputs 2 CSA/FM General Purpose, C-TICK C
(DPDT)
18 to 50 V DC PNP 3 CE, C-TICK D
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E
19 to 230 V AC/DC without contact, 2-wire loop 4 E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia
powered1) IIC, C-TICK6)
7 to 9 V DC (requires NAMUR switch amplifier) 5 ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F
NAMUR IEC 60947-5-6, 2-wire2) 3) 1/2D, C-TICK6)
8/16 mA or 4 to 20 mA; 12.5 to 35 V DC, 2-wire4) 6
Further designs Order code
Process temperature
Please add “-Z" to Order No. and specify Order
Up to +80 °C (+176 °F) A code(s).
Process connection Enter the total insertion length in plain text descrip- Y01
Threaded tion, 4000 mm (157.48")
R 1½" [(BSPT), EN 10226] A K05
Enhanced sensitivity > 5 g/l via electronics and
1½" NPT [(Taper), ANSI/ASME B1.20.1] B increased fork length to 195 mm (7.68")
Flanged Signal bulb inserted in M20 cable gland4) A20
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
C
D
NAMUR 8 to 16 mA switch amplifiers
Instruction manual
A15

Order No.
5
2" ASME 150 lbs B16.5 (1.4541/321) E Multi-language 7ML1998-5FT62
3" ASME 150 lbs B16.5 (1.4541/321) F
This device is shipped with the Siemens Milltronics
4" ASME 150 lbs B16.5 (1.4541/321) G
manual CD containing the complete ATEX Quick
Extension length Start and instruction manual library.
700 to 1000 mm (19.7 to 39.4")[max. length 10 Spare parts
20000 mm (787.4"), not with Power supply option 5
Replacement Electronics Module (125 Hz) 7ML1830-1KL
(max. 10000 mm, 393.7")]
[19 to 230 V AC, 19 to 55 V DC, one relay output
Add order code Y01 and plain text: “Insertion (SPDT)]
length ... mm" Replacement Electronics Module (350 Hz) 7ML1830-1KM
1001 to 2000 mm (39.41 to 78.74") 11 [19 to 230 V AC, 19 to 55 V DC, one relay output
2001 to 3000 mm (78.78 to 118.11") 12 (SPDT)]
3001 to 4000 mm (118.15 to 157.48") 13 1)
Available with approval options A to D only
4001 to 5000 mm (157.52 to 196.85") 2)
14 Available with approval options C to F only
3)
5001 to 6000 mm (196.89 to 236.22") 15 Cable length is limited to 10000 mm (393.70")
4)
6001 to 7000 mm (236.26 to 275.59") 16 Available with approval options C, D only
5) Cable length is limited to 7000 mm (275.59")
7001 to 8000 mm (275.63 to 314.96") 17 6)
Available with power supply option 5 and application type 1 only
8001 to 9000 mm (315 to 354.33") 18
9001 to 10000 mm (354.37 to 393.70") 20
10001 to 11000 mm (393.74 to 433.07") 21
11001 to 12000 mm (433.11 to 472.44") 22
12001 to 13000 mm (472.48 to 511.81") 23
13001 to 14000 mm (511.85 to 551.18") 24
14001 to 15000 mm (551.22 to 590.55") 25
15001 to 16000 mm (590.59 to 629.92") 26
16001 to 17000 mm (629.96 to 669.29") 27
17001 to 18000 mm (669.33 to 708.66") 28
18001 to 19000 mm (708.70 to 748.03") 30
19001 to 20000 mm (748.07 to 787.40") 31
Application type
Dry bulk solids (125 Hz) 1
Liquid/solids interface (350 Hz)5) 2

March 2009 Siemens FI 01 · 2009 US Edition 5/89


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200

■ Dimensional drawings
120 mm
(4.72”) VIEW A-A
A A
thread length
BSP: 20.5 mm
(0.81”)
NPT: 24 mm
tine (0.94”)
orientation 150 mm 155 mm
marking (5.91”) 60 mm (6.1")
(2.36”) 75 mm 42 mm (1.67")
(2.95”)
threaded bushing
[max. temp. 80 °C
(176 °F)]
700 to 20 000 mm** (27.56 to 787")
optional
sliding 60 mm
bushing* (2.36”)
customer
supplied
process flange 165 mm (6.5”): compact solids/liquids interface model
230 mm (9.0”): compact standard version 195 mm
tine
300 to 4000 mm (11.81 to 157”): customer-specified rigid extension (7.68")

Notes: 42 mm (1.67")
100 mm (3.94”) *The clamping screws of the sliding tine
solids/liquids bushing must be tightened to 10 Nm.
interface model 170 mm (6.69”): 100 mm (3.94”)
standard model ** Cable version with Liquids/solids interface solids/liquids
model option length to 7000 mm (275.59") interface model
Cable version with NAMUR electronics length to 170 mm (6.69”):
10 000 mm (393.7") standard model

See drawing 23650563 for pipe extended

5 Note: Please consult instruction manual for cable extension diagram.


version details. (Pipe is customer supplied.)

SITRANS LVS200 dimensions

5/90 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Vibrating switches
SITRANS LVS200

■ Schematics

SITRANS LVS200 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/91


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Rotating point level switch
Input
Measured variable High and low and demand
Output
Output signal
• Alarm output Microswitch 5 A at 250 V AC, non
inductive
Microswitch SPDT contact 4 A at
30 V DC, non-inductive
• Pickup delay Standard (1 rpm model): approx
1.3 seconds
Optional process applications (5
rpm model): approx. 0.26 sec-
onds
Sensitivity Adjustable via reset force of
spring or geometry of measuring
SITRANS LPS200 is a rotary paddle switch for point level detec- vane
tion in bulk solids.
Rated operating conditions

5 ■ Benefits Installation conditions

• Proven paddle switch technology for bulk solids • Location Indoor/outdoor


• High integrity mechanical seal Ambient conditions
• Optional switch selectable power supply • Ambient temperature -20 to +60 °C (-4 to +140 °F)
• Unique friction clutch mechanism • Installation catagory III
• Rotatable enclosure • Pollution degree 2
• Optional paddle for use with low density materials Medium conditions Bulk solids
• Simple installation through existing process connection • Temperature
• High temperature model and optional extension kit available - Standard -20 to +80 °C (-4 to +176 °F)
• Optional fail-safe configuration - Optional -20 to +350 °C (-4 to +662 °F)
• Pressure (vessel)
■ Application - Standard Max. 0.5 bar (7.25 psi)
The paddle switch technology detects full, empty or demand - Optional Max. 10 bar (145 psi)
conditions on materials such as grain, feed, cement, plastic
granulate and wood chips. The paddle switch can handle bulk • Minimum material density
densities as low as 15 g/l (2.19 lb/ft3) with the optional hinged - Standard measuring vane • Can detect down to 100 g/l
vane or 100 g/l (6.25 lb/ft3) with the standard measuring vane. (6.25 lb/ft3)
A low revolution geared motor with slip clutch drives a rotating - Optional measuring vane • Can detect down to15 g/l
measuring vane which senses the presence of material at the (2.19 lb/ft3)
mounted level of the LPS200. As material comes into contact Design
with the rotating paddle, rotation stops, which changes the mi-
croswitch state. When the paddle is no longer covered by ma- • Material
terial, rotation resumes and the relay reverts to its normal condi- - Enclosure Epoxy coated aluminum
tion. - Process connection, measuring Stainless steel or aluminum
The LPS200 has a rugged design for use in harsh conditions in shaft and vane
the solids industry. The sensitivity of the paddle can be adjusted • Process connection Thread NPT, BSP and flange
for varying material properties like buildup on the vane. options
The LPS200 comes in a variety of configurations including com- • Degree of protection IP65/Type 4/NEMA 4
pact, extended and cable extension. It is equipped with a stan- • Conduit entry 2 x M20x1.5 or 2 x ½" NPT
dard vane which is effective in most applications, but can be
configured with a hinged or rectangular vane for increased sen- Power supply
sitivity for light materials. • Jumper selectable • 115 V AC, ± 15%, 50 to 60 Hz,
• Key Applications: bulk solids such as grain, feed, cement, 4 VA or 230 V AC, ± 15%, 50 Hz,
plastic granulate, wood chips 6 VA, or 48 V AC, or 24 V AC
• or 24 V DC, ± 15%, 2.5 W
Certificates and approvals • CSA/FM General Purpose
• CE
• CSA/FM Dust Ignition Proof
• ATEX II 1/2 D
• C-TICK

5/92 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, compact 7ML 5 7 2 5 - SITRANS LPS200, compact 7ML 5 7 2 5 -
Rotary paddle switch for level detection in bulk Rotary paddle switch for level detection in bulk
7 7 7 77 - 77 7 0 7 7 7 77 - 77 7 0
solids solids
• Compact design for side or top mounted applica- • Compact design for side or top mounted applica-
tions tions
Process temperature Measuring vane
Up to +80 °C (+176 °F) 1 Boot shaped, 35 x 106 mm (1.38 x 4.17")7) } A
Up to +150 °C (+302 °F) 2 Hinged vane, 65 x 210 mm (2.56 x 8.27")7)8) B
Up to +250 °C (+482 °F) 3 Boot shaped, 28 x 98 mm (1.10 x 3.86") C
Up to +350 °C (+662 °F)1) 4 Rectangular 50 x 150 mm (1.97 x 5.91")9) D
Up to +80 °C (+176 °F) basic version aluminum2) 3)} 5 Rectangular 50 x 250 mm (1.97 x 9.84")9) E
Up to +80 °C (+176 °F) basic version stainless } 6 Rectangular 98 x 150 mm (3.86 x 5.91")9) F
steel 2) 4) Rectangular 98 x 250 mm (3.86 x 9.84")9) G
Power supply Approvals
230 V AC, 1 rev/min. } A CSA/FM Dust Ignition Proof, C-TICK } A
230 V AC, 1 rev/min., fail-safe B ATEX II 1/2 D, C-TICK } B
230 V AC, 5 rev/min. C CSA/FM General Purpose , C-TICK } C
230 V AC, 5 rev/min., fail-safe D CE, C-TICK } D
115 V AC, 1 rev/min. } E Further designs Order code
115 V AC, 1 rev/min., fail-safe F
Please add "-Z" to Order No. and specify Order
115 V AC, 5 rev/min. G code(s).
115 V AC, 5 rev/min., fail-safe H
Heating of enclosure10) 11) A35
48 V AC
24 V AC
J
K
Signal bulb inserted in M20 cable gland10) A20 5
SITRANS LPS200 designed for food applications K01
24 V DC, 1 rev/min. L with shaft seal conforming to FDA standards
24 V DC, 1 rev/min., fail-safe M
Additional instruction manual Order No.
24 V DC, 5 rev/min. N Multi-language 7ML1998-5FS62
24 V DC, 5 rev/min., fail-safe P
This device is shipped with the Siemens Milltronics
Switch selectable 230 V AC/115 V AC/24 V DC } Q manual CD containing the complete ATEX Quick
multivoltage, 1 rev/min. Start and instruction manual library.
Switch selectable 230 V AC/115 V AC/24 V DC R
multivoltage, 5 rev/min. Spare parts
Motor gear /PLC, multi-voltage 7ML1830-1KG
Process connection Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
Threaded (1.38 x 4.17")
G 1¼" [(BSPP), EN ISO 228-1] A Hinged vane, 65 x 210 mm (2.56 x 8.27") 7ML1830-1KJ
G 1" [(BSPP), EN ISO 228-1] B
Rigid extension kit
G 1½" [(BSPP), EN ISO 228-1] } C (includes spring coupling, rigid tube extension and
1" NPT [(Taper), ANSI/ASME B1.20.1] D required pins)
1¼" NPT [(Taper), ANSI/ASME B1.20.1] } E Extension: 500 mm, 400 mm, 300 mm 7ML5711-0AA
1½" NPT [(Taper), ANSI/ASME B1.20.1] F (19.7", 15.8", 11.8")
Extension: 1000 mm, 900 mm, 800 mm, 700 mm, 7ML5711-1AA
Flanged 600 mm (39.4", 35.4", 31.5", 27.6", 23.6")
DN 32 PN 6, EN1092-1 (1.4541/321) G Extension: 1500 mm, 1400 mm, 1300 mm, 7ML5711-2AA
DN 100 PN 6, EN1092-1 (1.4541/321) H 1200 mm, 1100 mm (59.1", 55.1", 51.2", 47.2",
DN 100 PN 16, EN1092-1 (1.4541/321) J 43.3")
2" ASME 150 lbs B16.5 (1.4541/321) K Available ex stock
3" ASME 150 lbs B16.5 (1.4541/321) L SITRANS LPS200, compact for up to +80 °C 7ML5725-
(+176 °F), aluminum, with power supply A, process 5AC11-2AD0
4" ASME 150 lbs B16.5 (1.4541/321) M
connection C, process pressure 1, process con-
Process pressure nection material 1, extension length 2, measuring
Up to 0.5 bar (7.25 psi) } 1 vane A, and approval D
Up to 5 bar (72.5 psi) 2 SITRANS LPS200, compact for up to +80 °C 7ML5725-
Up to 10 bar (145 psi) 3 (+176 °F), aluminum, with power supply E, process 5EE11-2AC0
connection E, process pressure 1, process con-
Process connection material nection material 1, extension length 2, measuring
Aluminum5) } 1 vane A, and approval C
Stainless steel 303 (1.4305) } 2
Extension length
100 mm (3.94")6) 1
150 mm (5.91") } 2
200 mm (7.87") 3
250 mm (9.84") 4
300 mm (11.81") 5

March 2009 Siemens FI 01 · 2009 US Edition 5/93


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

Selection and Ordering data Order No.


SITRANS LPS200, compact 7ML 5 7 2 5 -
Rotary paddle switch for level detection in bulk
7 7 7 77 - 77 7 0
solids
• Compact design for side or top mounted applica-
tions
SITRANS LPS200, compact for up to +80 °C 7ML5725-
(+176 °F), stainless steel, with power supply Q, 6QC12-2AB0
process connection C, process pressure 1, pro-
cess connection material 2, extension length 2,
measuring vane A, and approval B
SITRANS LPS200, compact for up to +80 °C 7ML5725-
(+176 °F), stainless steel, with power supply Q, 6QE12-2AA0
process connection E, process pressure 1, process
connection material 2, extension length 2, measur-
ing vane A, and approval A
1)
Available with approval option C and D only, up to max. 0.8 bar
2)
Basic version is cost effective and offers fast delivery
3)
Available only with power supply option A and with process connection C,
and approval D, or power supply E with process connection E, and
approval C, and then process pressure 1, process connection material 1,
extension length 2, measuring vane A
4)
Available only with power supply option Q, process connection C with
approval B, or process connection E with approval A, and then process
pressure 1, process connection material 2, extension length 2 and measur-
ing vane A

5
5)
Available with process connections A to F, process pressure option 1, and
process temperature option 1 only
6)
Available with measuring vane options A, C to G, only
7)
Add 16 mm (0.63") to extension length
8) Available with extension length options 2 to 5 only
9)
Available with process connections G, H, J to M, only
10)
Available with approval options C, D only
11)
Available with power supply options A to H, J to N, P only
} Available ex stock.

5/94 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, Extended 7ML 5 7 2 6 - SITRANS LPS200, Extended 7ML 5 7 2 6 -
Rotary paddle switch for level detection in bulk Rotary paddle switch for level detection in bulk
7 7 7 77 - 77 7 7 7 7 7 77 - 77 7 7
solids solids
Shaft protected designed with added protection Shaft protected designed with added protection
tube for enhanced shaft protection tube for enhanced shaft protection
Process temperature Measuring vane
Up to +80 °C (+176 °F) 1 Boot shaped 35 x 106 mm (1.38 x 4.17")6) } A
Up to +150 °C (+302 °F) 2 Hinged vane 65 x 210 mm (2.56 x 8.27")6) B
Up to +250 °C (+482 °F) 3 Rectangular 50 x 150 mm (1.97 x 5.91")7) D
Up to +350 °C (+662 °F)1) 4 Rectangular 50 x 250 mm (1.97 x 9.84")7) E
Up to +80 °C (+176 °F) basic version2) } 5 Rectangular 98 x 150 mm (3.86 x 5.91")7) F
Power supply Rectangular 98 x 250 mm (3.86 x 9.84")7) G
230 V AC, 1 rev/min. A Approvals
230 V AC, 1 rev/min., fail-safe B CSA/FM Dust Ignition Proof, C-TICK } 1
230 V AC, 5 rev/min. C ATEX II 1/2 D, C-TICK } 2
230 V AC, 5 rev/min., fail-safe D CSA/FM General Purpose, C-TICK 3
115 V AC, 1 rev/min. E CE, C-TICK 4
115 V AC, 1 rev/min., fail-safe F Further designs Order code
115 V AC, 5 rev/min. G Please add "-Z" to Order No. and specify Order
115 V AC, 5 rev/min., fail-safe H code(s).
48 V AC J
Heating of enclosure8) 9) A35
24 V AC
24 V DC, 1 rev/min.
K
L
Signal bulb inserted in M20 cable gland8)
SITRANS LPS200 designed for food applications
A20
K01
5
24 V DC, 1 rev/min., fail-safe M with shaft seal conforming to FDA standards
24 V DC, 5 rev/min. N Additional instruction manual Order No.
24 V DC, 5 rev/min., fail-safe P Multi-language 7ML1998-5FS62
Switch selectable 230 V AC/115 V AC/24 V DC } Q This device is shipped with the Siemens Milltronics
multivoltage, 1 rev/min. manual CD containing the complete ATEX Quick
Switch selectable 230 V AC/115 V AC/24 V DC R Start and instruction manual library.
multivoltage, 5 rev/min.
Spare parts
Process connection Motor gear /PLC, multi-voltage 7ML1830-1KG
Threaded Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
G 1¼"[(BSPP), EN ISO 228-1] A (1.38 x 4.17")
G 1½" [(BSPP), EN ISO 228-1] } B Hinged vane, 65 x 210 mm (2.56 x 8.27") 7ML1830-1KJ
1¼" NPT [(Taper), ANSI/ASME B1.20.1] } C
Available ex stock
1½" NPT [(Taper), ANSI/ASME B1.20.1] D
SITRANS LPS200, extended for up to +80 °C 7ML5726-
Flanged (+176 °F), power supply Q, process connection B, 5QB12-2BA2
process pressure 1, process connection material 2,
DN 32 PN 6, EN1092-1 (1.4541/321) E extension length 2, extension material B, measur-
DN 100 PN 6, EN1092-1 (1.4541/321) F ing vane A, and approval 2
DN 100 PN 16, EN1092-1 (1.4541/321) G SITRANS LPS200, extended for up to +80 °C 7ML5726-
2" ASME 150 lbs B16.5 (1.4541/321) H (+176 °F), power supply Q, process connection C, 5QC12-2BA1
process pressure 1, process connection material 2,
3" ASME 150 lbs B16.5 (1.4541/321) J extension length 2, extension material B, measur-
4" ASME 150 lbs B16.5 (1.4541/321) K ing vane A, and approval 1
Process pressure 1)
Available with approval option 3 and 4 only, up to max. 0.8 bar
Up to 0.5 bar (7.25 psi) } 1 2)
Available with power supply option Q (process connection B with approval
Up to 5 bar (72.5 psi) 2 2 or process connection C with approval 1), process pressure 1, process
Up to 10 bar (145 psi) 3 connection material 2, extension length 2, protection tube B and measuring
vane A only
Process connection material 3)
Available with process connections A to D, and process temperature option
Aluminum3) 4) 1 1 only
4)
Stainless steel 303 (1.4305) } 2 Available with process pressure option 1 only
5)
Not available with measuring vane option B
Extension length 6) Add 16 mm (0.63") to extension length
150 mm (5.91")5) 1 7) Available with process connections E to H, J, K, only
200 mm (7.87") 8)
} 2 Available with approval options 3, 4 only
9)
Available with power supply options A to H, J to N, P only
250 mm (9.84") 3
300 mm (11.81") 4 } Available ex stock.
Extension material (protection tube)
Aluminum3) A
Stainless steel 303 (1.4305) } B

March 2009 Siemens FI 01 · 2009 US Edition 5/95


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, cable extension 7ML 5 7 2 7 - SITRANS LPS200, cable extension 7ML 5 7 2 7 -
Rotary paddle switch for level detection in bulk 7 7 7 77 - 77 7 0
Rotary paddle switch for level detection in bulk 7 7 7 77 - 77 7 0
solids solids
Cable extension for increased length in Cable extension for increased length in
top-mounted applications top-mounted applications
Process temperature Measuring vane
Up to +80 °C (+176 °F) 1 Boot shaped, 35 x 106 mm (1.38 x 4.17")4) A
Up to +150 °C (+302 °F) 2 Hinged vane, 65 x 210 mm (2.56 x 8.27")4) B
Up to +250 °C (+482 °F) 3 Boot shaped, 28 x 98 mm (1.10 x 3.86") C
Up to +350 °C (+662 °F)1) 4 Rectangular 50 x 150 mm (1.97 x 5.91")5) D
Up to +80 °C (+176 °F) basic version2) 5) 5 Rectangular 50 x 250 mm (1.97 x 9.84")5) E
Rectangular 98 x 150 mm (3.86 x 5.91")5) F
Power supply
230 V AC, 1 rev/min. A Approvals
230 V AC, 1 rev/min., fail-safe B CSA/FM Dust Ignition Proof, C-TICK A
230 V AC, 5 rev/min. C ATEX II 1/2 D, C-TICK B
CSA/FM General Purpose, C-TICK C
230 V AC, 5 rev/min., fail-safe D
115 V AC, 1 rev/min. E CE, C-TICK D
115 V AC, 1 rev/min., fail-safe F Further designs Order code
115 V AC, 5 rev/min. G Please add "-Z" to Order No. and specify Order
115 V AC, 5 rev/min., fail-safe H code(s).
48 V AC J Total insertion length: Y01
24 V AC K Enter the total insertion length in plain text descrip-

5 24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
L
M
tion, max. 10000 mm (393.70")
Reinforced cable (max. 28 kN pulling force) P01
24 V DC, 5 rev/min. N Heating of enclosure6) 7) A35
24 V DC, 5 rev/min., fail-safe P Signal bulb inserted in M20 cable gland6) A20
Switch selectable 230 V AC/115 V AC/24 V DC Q Additional instruction manual Order No.
multivoltage, 1 rev/min.
Multi-language 7ML1998-5FS62
Switch selectable 230 V AC/115 V AC/24 V DC R
multivoltage, 5 rev/min. This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Process connection Start and instruction manual library.
Threaded
G 1¼" [(BSPP), EN ISO 228-1] A Spare parts
G 1½" [(BSPP), EN ISO 228-1] B Motor gear /PLC, multi-voltage 7ML1830-1KG
1¼" NPT [(Taper), ANSI/ASME B1.20.1] C Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
(1.38 x 4.17")
1½" NPT [(Taper), ANSI/ASME B1.20.1] D
Hinged vane, 65 x 210 mm (2.56 x 8.27") 7ML1830-1KJ
Flanged Rope extension kit, 2 m (6.56 ft) 7ML1830-1KK
DN 32 PN 6, EN1092-1 (1.4541/321) E Available ex stock
DN 100 PN 6, EN1092-1 (1.4541/321) F SITRANS LPS200, cable extension for up to +80 °C 7ML5727-
DN 100 PN 16, EN1092-1 (1.4541/321) G (+176 °F), power supply Q, process connection B, 5QB12-0AB0
2" ASME 150 lbs B16.5 (1.4541/321) H process pressure 1, process connection material 2,
extension length 0, measuring vane A, and
3" ASME 150 lbs B16.5 (1.4541/321) J
approval B
4" ASME 150 lbs B16.5 (1.4541/321) K
SITRANS LPS200, cable extension for up to +80 °C 7ML5727-
Process pressure (+176 °F), power supply Q, process connection C, 5QC12-0AA0
Up to 0.5 bar (7.25 psi) 1 process pressure 1, process connection material 2,
Up to 5 bar (72.5 psi) 2 extension length 0, measuring vane A, and
Up to 10 bar (145 psi) 3 approval A
1) Available with approval option C and D only, up to max. 0.8 bar
Process connection material
2)
Aluminum3) 1 Available only with Power supply Q, (Process connection B with Approvals
Stainless steel 303 (1.4305) 2 B or Process connection C with Approvals A), Process pressure 1, Process
connection material 2, Cable Extension length 0 and Measuring Vane A
Cable extension length 3)
Available with process connections A to D, process pressure option 1, and
Standard cable length, 2000 mm (78.74") 0 process temperature option 1 only
4)
Add order code Y01 and plain text: “Insertion Add 16 mm (0.63") to extension length
5)
length ... mm" Available with process connections E to H, J, K, only
6)
500 to 1000 mm (19.69 to 39.37") 1 Available with approval options C, D only
7)
Cable length 1001 to 2000 mm (39.41 to 78.74") 2 Available with power supply options A to H, J to N, and P, only
Cable length 2001 to 3000 mm (78.78 to 118.11") 3
Cable length 3001 to 4000 mm (118.15 to 157.48") 4
Cable length 4001 to 5000 mm (157.52 to 196.85") 5
Cable length 5001 to 6000 mm (196.89 to 236.22") 6
Cable length 6001 to 7000 mm (236.26 to 275.59") 7
Cable length 7001 to 10000 mm 8
(275.63 to 393.70")

5/96 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, angled extension 7ML 5 7 2 8 - SITRANS LPS200, angled extension 7ML 5 7 2 8 -
Rotary paddle switch with robust design for level 7 7 7 77 - 77 7 0
Rotary paddle switch with robust design for level 7 7 7 77 - 77 7 0
detection in bulk solids detection in bulk solids
Angled extension designed to avoid falling material Angled extension designed to avoid falling material
in side mount applications in side mount applications
Process temperature Further designs Order code
Up to +80 °C (+176 °F) 1 Please add "-Z" to Order No. and specify Order
Up to +150 °C (+302 °F) 2 code(s).
Up to +250 °C (+482 °F) 3
Heating of enclosure1) 2) A35
Power supply
Signal bulb inserted in M20 cable gland1) A20
230 V AC, 1 rev/min. A
230 V AC, 1 rev/min., fail-safe B Additional instruction manual Order No.
230 V AC, 5 rev/min. C Multi-language 7ML1998-5FS62
230 V AC, 5 rev/min., fail-safe D This device is shipped with the Siemens Milltronics
115 V AC, 1 rev/min. E manual CD containing the complete ATEX Quick
115 V AC, 1 rev/min., fail-safe F Start and instruction manual library.
115 V AC, 5 rev/min. G Spare parts
115 V AC, 5 rev/min., fail-safe H Motor gear /PLC, multi-voltage 7ML1830-1KG
48 V AC J Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
(1.38 x 4.17")
24 V AC K Hinged vane, 65 x 210 mm (2.56 x 8.27") 7ML1830-1KJ
24 V DC, 1 rev/min. L
1)
24 V DC, 1 rev/min., fail-safe M Available with approval options C, D only
2)
Available with power supply options A to H, J to N, P only
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
N
P 5
Switch selectable 230 V AC/115 V AC/24 V DC Q
multivoltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC R
multivoltage, 5 rev/min.
Process connection
Flanged
DN 100 PN 6, EN1092-1 (1.4541/321) A
DN 100 PN 16, EN1092-1 (1.4541/321) B
4" ASME 150 lbs B16.5 (1.4541/321) C
Process pressure
Up to 0.5 bar (7.25 psi) 1
Up to 5 bar (72.5 psi) 2
Up to 10 bar (145 psi) 3
Process connection material
Stainless steel 303 (1.4305) 1
Extension length
125 mm (4.92") 1
150 mm (5.91") 2
200 mm (7.87") 3
250 mm (9.84") 4
300 mm (11.81") 5
Measuring vane
Rectangular vane, 50 x 98 mm (1.97 x 3.86") A
Rectangular vane, 50 x 150 mm (1.97 x 5.91") B
Rectangular vane, 50 x 250 mm (1.97 x 9.84") C
Rectangular vane 98 x 150 mm (3.86 x 5.91") D
Rectangular vane 98 x 250 mm (3.86 x 9.84") E
Hinged vane, 65 x 210 mm (2.56 x 8.27") F
Approvals
CSA/FM Dust Ignition Proof, C-TICK A
ATEX II 1/2 D, C-TICK B
CSA/FM General Purpose, C-TICK C
CE, C-TICK D

March 2009 Siemens FI 01 · 2009 US Edition 5/97


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LPS200, rigid extension 7ML 5 7 3 0 - SITRANS LPS200, rigid extension 7ML 5 7 3 0 -
Rotary paddle switch for level detection in bulk 7 7 7 77 - 77 7 7
Rotary paddle switch for level detection in bulk 7 7 7 77 - 77 7 7
solids solids
Process temperature Stainless steel 303 (1.4305)
Up to +80 °C (+176 °F) 1 250 to 500 mm (9.84 to 19.69") R
Up to +150 °C (+302 °F) 2 501 to 750 mm (19.72 to 29.53") S
Up to +250 °C (+482 °F) 3 751 to 1000 mm (29.57 to 39.37") T
Up to +350 °C (+662 °F)1) 4 1001 to 1500 mm (39.41 to 59.05") U
Power supply 1501 to 2000 mm (59.09 to 78.74") V
230 V AC, 1 rev/min. A 2001 to 2500 mm (78.78 to 98.42") W
230 V AC, 1 rev/min., fail-safe B 2501 to 3000 mm (98.46 to 118.11”) X
230 V AC, 5 rev/min. C 3001 to 4000 mm (118.14.78 to 157.48”) Y
230 V AC, 5 rev/min., fail-safe D Measuring vane
115 V AC, 1 rev/min. E Boot shaped, 35 x 106 mm (1.34 x 4.17")6) A
115 V AC, 1 rev/min., fail-safe F Hinged vane, 60 x 200 mm (2.36 x 7.87") B
115 V AC, 5 rev/min. G Rectangular 50 x 150 mm (1.97 x 5.91")7) C
115 V AC, 5 rev/min., fail-safe H Rectangular 50 x 250 mm (1.97 x 9.84")7) D
48 V AC J Rectangular 98 x 150 mm (3.86 x 5.91")7) E
24 V AC K Rectangular 98 x 250 mm (3.86 x 9.84")7) F
24 V DC, 1 rev/min. L Approvals
24 V DC, 1 rev/min., fail-safe M CSA/FM Dust Ignition Proof, C-TICK 1
24 V DC, 5 rev/min. ATEX II 1/2 D, C-TICK 2
5
N
24 V DC, 5 rev/min., fail-safe P CSA/FM General Purpose, C-TICK 3
Switch selectable 230 V AC/115 V AC/24 V DC Q CE, C-TICK 4
multivoltage, 1 rev/min. Further designs Order code
Switch selectable 230 V AC/115 V AC/24 V DC R
Please add "-Z" to Order No. and specify Order
multivoltage, 5 rev/min.
code(s).
Process connection
Total insertion length: Enter the total insertion length Y01
Threaded in plain text description, max. 4000 mm (157.48")
G 1¼" [(BSPP), EN ISO 228-1] A
G 1½" [(BSPP), EN ISO 228-1] B Heating of enclosure8) 9) A35
1¼" NPT [(Taper), ANSI/ASME B1.20.1] C Signal bulb inserted in M20 cable gland8) A20
1½" NPT [(Taper), ANSI/ASME B1.20.1] D SITRANS LPS200 designed for food applications K01
Flanged with shaft seal conforming to FDA standards
DN 32 PN 6, EN1092-1 (1.4541/321) E Seal at tube end for ingress protection and shaft
DN 100 PN 6, EN1092-1 (1.4541/321) F stability
DN 100 PN 16, EN1092-1 (1.4541/321) G - Max. temperature +80 °C (+176 °F) P06
2" ASME 150 lbs B16.5 (1.4541/321) H - Max. temperature +150 °C (+302 °F) P07
3" ASME 150 lbs B16.5 (1.4541/321) J
- Max. temperature +250 °C (+482 °F) P08
4" ASME 150 lbs B16.5 (1.4541/321) K
- Max. temperature +350 °C (+662 °F) P09
Process pressure
Up to 0.5 bar (7.25 psi) 1 Sliding sleeve (standard, max. pressure 0.8 bar) P12
Up to 5 bar (72.5 psi) 2 Sliding sleeve (pressure tight, for over-pressure P13
Up to 10 bar (145 psi) 3 application starting from 1 bar max., dependent on
pressure option ordered)
Process connection material
Aluminum2) 3) 1 Additional instruction manual Order No.
Stainless steel 303 (1.4305) 2 Multi-language 7ML1998-5FS62
Extension material (protection tube) This device is shipped with the Siemens Milltronics
Aluminum2) 4) 5) 0 manual CD containing the complete ATEX Quick
Stainless steel 303 (1.4305) 1 Start and instruction manual library.
Extension length Spare parts
Aluminum Motor gear /PLC, multi-voltage 7ML1830-1KG
250 to 500 mm (9.84 to 19.69") A Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH
(1.38 x 4.17")
501 to 750 mm (19.72 to 29.53") B
Hinged vane, 65 x 210 mm (2.56 x 8.27") 7ML1830-1KJ
751 to 1000 mm (29.57 to 39.37") C
1)
1001 to 1250 mm (39.41 to 42.21") D Available with approval option 3 and 4 only, up to max. 0.8 bar
2)
1251 to 1500 mm (49.25 to 59.06") E Available with process connections A to D only
3)
1501 to 1750 mm (59.09 to 68.90") F Available with process pressure option 1 only
4)
Available with process connection material option 1 only
1751 to 2000 mm (68.94 to 78.74") G 5)
Available with process temperature option 1 only
2001 to 2250 mm (78.78 to 88.58") H 6) Add 16 mm (0.63") to extension length
2251 to 2500 mm (88.62 to 98.43") J 7)
Available with process connections E to H, J, K, only
8)
2501 to 2750 mm (98.46 to 108.27") K Available with approval options 3, 4 only
9)
2751 to 3000 mm (108.31 to 118.11") L Available with power supply options A to H, J to N, P, only
3001 to 3250 mm (118.15 to 127.95") M
3251 to 3500 mm (127.99 to 137.80") N
3501 to 3750 mm (137.83 to 147.64") P
3751 to 4000 mm (147.67 to 157.48") Q

5/98 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

■ Dimensional drawings
Standard model: compact version
conduit connection M20 or ½“ NPT
L = Length
100 mm 3.94"
60 mm (2.36”) 150 mm 5.91"
200 mm 7.87"
60 mm (2.36”) 250 mm 9.84"
300 mm 11.81"
75 mm (2.95”)

120 mm
(4.72”)
ambient temperature extended option angle option rope option
-20 to +60 °C
(-4 to +140 °C)
123 mm (4.84”)
Zone 21
(Cat. 2)
Zone 20 thread length rope
(Cat. 1) BSP: 20.5 mm (0.81”) fixing
NPT: 24 mm (0.94”) optional
1)
process
L flange 1)
process temperature L 125 to 300 mm
-20 to +80 °C (4.92 to 8.46”)
(-4 to +176 °C)
2000 mm
(78.74”)
standard;
5
measuring vane can be
shortened by
the customer

High Temperature Model: compact version

extended option angle option rope option


thread length 340 mm (13.4”)
ambient temperature BSP: 20.5 mm
-20 to +60 °C (0.81”)
(-4 to +140 °C) NPT: 24 mm
(0.94”)
rope
fixing
Zone 21
(Cat. 2)
Zone 20 1)
125 to 300 mm 2000 mm
(Cat. 1) L (4.92 to 8.46”) (78.74”)
standard;
can be
process temperature2) L1) shortened by
-20 to +220 °C the customer;
(-4 to +428 °C) total length
available
10000 mm
(393.7")

Measuring Vanes

Standard Hinged
106 mm
(4.17”)
fold 65 mm
together (2.56”)
to lead min. 37 mm
into (1.46”)
mounting 210 mm
35 mm hole (8.27”)
(1.38”)

1. For 35 X 106 mm boot shaped and 65 X 210 mm hinged measuring vanes, add 16 mm to extension length.
2. For use with all approval options except CSA Class II. See manual for more details.

Notes
For heavy material, only top mounting of paddle switch is recommended.
Compact LPS200 is recommended for side mounting on bins for low or intermediate material levels.

SITRANS LPS200 dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/99


© Siemens AG 2009

Level instruments
Point level measurement - Rotary paddle switches
SITRANS LPS200

■ Schematics

SITRANS LPS200 connections

5/100 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Ultrasonic switch
Ultrasonic

■ Overview ■ Mode of operation


Introduction Common Terms
Ultrasonic measurement is based on the speed of sound. Sound Attenuation
can be used as a measurement tool because there is a measur-
able time lapse between sound generation and the "hearing" of Denotes a decrease in signal magnitude in transmission from
the sound. This time lapse is then converted into usable informa- one point to another. Attenuation may be expressed as a scalar
tion. Ultrasonic sensing equipment generates a sound above ratio of the input magnitude to the output magnitude or in deci-
20000 Hz and then interprets the time lapse of the returned bels.
echo. The transducer creates the sound and senses the echo Beam angle
and then a transceiver interprets the sound and converts it into
information. The diameter of a conical boundary centered around the axis of
transmission when the power (radiating perpendicular to the
Siemens ultrasonic units include Sonic Intelligence, a patented transducer face on the axis of transmission) is reduced by half
signal processing technology. Using unique algorithms, Sonic (-3 dB).
Intelligence differentiates between true echoes from the material
and false echoes from obstructions or electrical noise, providing Blanking distance
intelligent processing of echo profiles. Specified zone extending downward from the transducer face in
Typical System which received echoes are ignored by the transceiver. Blanking
distance ignores echoes from ringing.
Ultrasonic level measurement requires two components: one to
generate the sound and catch the echo (transducer) and one to Echo confidence
interpret the data and derive a measurement (transceiver). Even The recognition of the validity of the echo as material level. A
though some ultrasonic instruments combine the components in measure of echo reliability.
one unit, the individual functionality remains distinct. The mea-
surement output is communicated to the unit, PLCs or PCs for
process control.
Ringing
5
The inherent nature of the transducer to continue vibrating after
Principle of Operation the transmit pulse has ceased; the decay of the transmit pulse.

A piezoelectric crystal inside the transducer converts an electri- Transducer/Transceiver


cal signal into sound energy, firing a burst into the air which trav- A transducer provides the initial ultrasonic pulse and receives its
els to the target and then is reflected back to the transducer. The echo. An ultrasonic transducer amplifies the sound wave cre-
transducer then acts as a receiving device and converts the ated by the piezoelectric crystal and transmits that sound wave
sonic energy back into an electrical signal contained in the to the face of the transducer while at the same time dampening
transceiver. An electronic signal processor analyzes the return the sound wave from the other sides of the crystal.
echo and calculates the distance between the transducer and
the target. The time lapse between firing the sound burst and re- Transceivers analyze the echo from the transducer to determine
ceiving the return echo is directly proportional to the distance the required measurement.
between the transducer and the material in the vessel. This ba-
sic principle lies at the heart of the ultrasonic measurement tech-
nology and is illustrated in the equation: Distance = (Velocity of
Sound x Time)/2.

March 2009 Siemens FI 01 · 2009 US Edition 5/101


© Siemens AG 2009

Level instruments
Point level measurement - Ultrasonic switch
Ultrasonic

■ Technical specifications
Ultrasonics Transmitter/Controller Selection Guide
Criteria SITRANS HydroRanger MultiRanger SITRANS LUC500 SITRANS LU OCM III
Probe LU 200 100/200
Range 6 m (20 ft) or 15 m (50 ft) trans- 15 m (50 ft) trans- 15 m (50 ft) trans- 60 m (200 ft) trans- 3 m (10 ft)
12 m (40 ft) ducer and applica- ducer and applica- ducer and applica- ducer and applica-
tion dependent tion dependent tion dependent tion dependent
Typical applications Chemical storage Wet wells, Wet wells, Wet well/lift station Chemical storage, Open channel mea-
vessels, filter beds, flumes/weirs, bar flumes/weirs, bar control, liquid storage, bulk surement
liquid storage ves- screen control screen control, hop- weirs/flumes, open solids storage
sels pers, chemical stor- channels (sugar, flour bins,
age, liquid storage, grains, cereals),
crusher bins, dry plastic pellets
solids storage
Output HART model: 6 relays standard, 1 relay (option on 5 relays, 4 to 20 mA 4 relays (LU01, 3 relays, 4 to 20 mA
4 to 20 mA/HART two 4 to 20 mA out- MultiRanger 100) (option) LU02)
PROFIBUS PA puts (isolated) 3 relays standard Up to 40 relays
model: PROFIBUS 6 relays (option) (LU10)
Two 4 to 20 mA out- 4 to 20 mA isolated
puts (isolated)
Communications HART or PROFIBUS Built-in Modbus Built-in Modbus Telemetry capability Dolphin, RS- Via RS-232
PA RTU/ASCII via RS- RTU or ASCII via with Modbus 232/RS-485 (LU01, Options:
485 RS-485 RTU/ASCII via LU02)
5 Options:
• SIMATIC PDM for Options: Options: RS-232/RS-485
Options:
Dolphin via infrared
(LU10)
• Flow Reporter
software
remote configura- • SIMATIC PDM • SIMATIC PDM
tion and diagnos- • SmartLinx • Smartlinx • SIMATIC PDM Options:
tics (PROFIBUS DP, (PROFIBUS DP, • SmartLinx • SmartLinx
Allen-Bradley Re- Allen-Bradley Re- (PROFIBUS DP, (PROFIBUS DP,
mote I/O, mote I/O, Allen-Bradley Re- Allen-Bradley Re-
DeviceNet) DeviceNet) mote I/O, mote I/O,
DeviceNet) DeviceNet)
• ECT EnviroRanger
Tool software
Power specifica- HART: 4 to 20 mA, AC version: 100 to AC version: 100 to AC version: 100 to LU01, LU02: 100/115/200/230 V
tions 24 V DC nominal, 230 V AC ±15%, 230 V AC ±15%, 230 V AC ±15%, AC version: AC, ±15%,
max. 550 Ω, 50/60 Hz, 50/60 Hz, 50/60 Hz, 100/115/200/ 50/60 Hz, 15 VA
30 V DC max. 36 VA/17 W 36 VA/17 W 30 VA/17 W 230 V AC and/or
PROFIBUS PA: 12, DC version: 12 to DC version: 12 to DC version: 12 to DC version: 18 to 9 to 30 V DC, 8 W
13, 15, or 20 mA, 30 V DC, 20 W 30 V DC, 20 W 30 V DC, 20 W 30 V DC, 25 W
dependent on pro- LU10: 100/115/200/
gramming 230 V AC

Approvals CE, CSANRTL/C, FM, CE, CSANRTL/C, UL CE, CSANRTL/C, UL CE, CSANRTL/C, UL CE, CSANRTL/C, FM, CE, CSANRTL/C, FM
C-TICK, ATEX, Listed, FM, Listed, FM, Listed Lloyd’s Register
ANZEx, IECEx C-TICK C-TICK

Handheld programmer selection guide

5/102 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Ultrasonic switch
Ultrasonic

Ultrasonic Level Application Questionnaire


Customer information
Contact: Prepared By:
Company: Date:
Address: Notes on the Application:
City: Country:
Zip/Postal Code: Phone: ( )

E-mail: Fax: ( )

Tanks/Vessel information (Supply sketch where possible) Sketch attached

Type: Storage Dimensions: Critical Information

Process Height: m/ft Nozzle Length: cm/in 5


Pump station Width/Diameter: m/ft Nozzle Diameter: cm/in

Open channel

Tank top: Open Tank bottom: Sloped Internal equipment No


and/or obstructions:
Flat Flat (E.g. Agitator, Heating coils, Yes Please list
Supports, Other)

Conical Conical

Parabolic Parabolic

Measurement type: Point Level Continuous Level Volume Flow


Area safety classification: (specify code required)

Material
Material being measured: Slurry Liquid Solid

Material temperature: Norm: °C/°F Max: °C/°F


Atmosphere: Air Other Homogenous: Yes No

Dust: None Light Heavy

Installation (indicate all that apply)

Power available: Communications:


Inputs required: Outputs required: HART ® /4 to 20 mA AB Remote I/O
4 to 20 mA 4 to 20 mA PROFIBUS DP AB DeviceNet
Pump Interlocks (#): Relays (#): PROFIBUS PA None
Modbus RTU/ASCII

Products recommended:
© Siemens Milltronics Process Instruments Inc. www.siemens.com/processautomation Form# 2-769R3

March 2009 Siemens FI 01 · 2009 US Edition 5/103


© Siemens AG 2009

Level instruments
Point level measurement - Ultrasonic switch
Pointek ULS200

■ Overview Mounting and Interconnection


The Pointek ULS200 is available in three thread types: 2" NPT, R
2" (BSPT), EN 10226 or PF2 and can be fitted with the optional
75 mm (3") flange adapter for mating to 3" ASME, DN 65, PN 10
and JIS 10K 3B sized flanges.
Separate cables and conduit may be required to conform to
standard instrumentation wiring or electrical codes.

■ Configuration

The Pointek ULS200 is an ultrasonic non-contacting switch with


two switch points for level detection of bulk solids, liquids and
slurries in a wide variety of industries; ideal for sticky materials.

5 ■ Benefits
• 2 switch outputs for high-high, high, low and low-low level
alarms or pump up/pump down control
• Integral temperature compensation
• AC or DC power supply
• Electronics provided with fail-safe function
• Threaded and 3A approved sanitary fitting clamp process
connections
• Polycarbonate or aluminum enclosures, Type 6/NEMA 6/IP67
• Easy, two-button programming

■ Application
The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m
(16.4 ft) for liquids and slurries. Unlike invasive contacting de-
vices, there is no material buildup on the sensor.
The level switch has a rugged design, combining the transducer
and electronics in one durable device. It has no moving parts
and is virtually maintenance-free.
The transducer, available in ETFE or PVDF copolymer, is inert to
most chemicals. This means the device can be used in the
chemical, petrochemical, water and wastewater industries. A
sanitary version of the ULS200, with an industry standard flange
option, is easy to remove from the application for cleaning. It
thus satisfies the prerequisites for use in the food, beverage and
pharmaceutical industries. The Pointek ULS200 delivers supe-
rior performance while reducing maintenance, downtime and
equipment replacement costs.
• Key Applications: liquids, slurries, fluid materials, plugged
chute detection, chemical industry
Pointek ULS200 Mounting
■ Design
Installation
The Pointek ULS200 should be mounted in an area that is within
the temperature range specified and that is suitable to the enclo-
sure rating and materials of construction. The cover should be
accessible to allow programming, wiring and display viewing.
It is advisable to keep the Pointek ULS200 away from high volt-
age or current runs, contactors and SCR control drives.
Locate the Pointek ULS200 so that it has a clear sound path per-
pendicular to the material surface. The sound path should not in-
tersect the fill path, rough walls, seams, rungs etc.

5/104 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Ultrasonic switch
Pointek ULS200

■ Technical specifications Certificates and approvals • CE (EMC certificate available on


request), CSAUS/C, FM
Mode of operation • CSA/FM Class I, II, III, Div. 1, Gr
Measuring principle Ultrasonic level switch A, B, C, D, E, F, G T4
• ATEX II 2G EEx md IIC T5
Measuring range • 3A Approval
• C-TICK
Measuring range in liquids 0.25 to 5 m (0.8 to 16.4 ft) • INMETRO: Br-EEx md IIC T5
Measuring range in bulk solids 0.25 to 3 m (0.8 to 9.8 ft)
Output
AC Version (relay) 2 SPDT Form C contacts rated 5A
at 250 V AC, resistive load
DC Version (relay) 2 SPDT Form C contacts rated 5A
at 48 V DC
DC Version (transistor) 2 switches, rated max. 100 mA,
48 V DC
Accuracy
AC/DC version
• Resolution 3 mm (0.1“)
• Repeatibility 0.25% of measuring range
Rated operation conditions
Installation conditions
• Location Indoors/outdoors
• Beam angle 12° 5
Ambient conditions
• Ambient temperature -40 to +60 °C (-40 to +140 °F)
• If mounted in metal threads -20 to +60 °C (-5 to +140 °F)
Medium conditions
• Process pressure 0.5 bar (7.25 psi) max.
Design
Material Polycarbonate or epoxy-coated
aluminum with gasket
Weight Approx. 1.5 kg (3.3 lbs)
Transducer material PVDF copolymer
Threaded mounting 2“ NPT [(Taper), ANSI/ASME
B1.20.1]
R 2“ [(BSPT), EN 10226]
or G 2" [(BSPP), EN ISO 228-1]
• Optional flange adapter For 3“ ASME, DN 65, PN 10 and
JIS 10 K3B
Sanitary mounting 4" sanitary fitting clamp according
to 3A guidelines
Power supply
AC version 100 to 230 V AC, ± 15%,
50/60 Hz, max. 12 VA, 5 W
DC version 18 to 30 V DC, 3 W
Displays and controls
Display LCD, three digits, 9 mm (0.35“)
high, for display of distance
between sensor face and mate-
rial, multisegment graphic for
operating state
Memory EEPROM, non-volatile
Programming 2 keys
Electronics/enclosure Connection: terminal block, max.
2.5 mm2 (14 AWG) solid/1.5 mm2
(16 AWG) stranded
Degree of protection IP67/Type 6/NEMA 6
Cable inlet 2 x ½“ NPT or 2 x PG 13.5

March 2009 Siemens FI 01 · 2009 US Edition 5/105


© Siemens AG 2009

Level instruments
Point level measurement - Ultrasonic switch
Pointek ULS200

Selection and Ordering data Order No. ■ Options


Pointek ULS200 C) 7 M L 1 5 1 0 -
Ultrasonic non-contacting switch with two switch Flange adapter for mating 2” NPT or 2” BSP process connections
777 0 7
points for level detection of bulk solids, liquids and
slurries in a wide variety of industries; ideal for
to 3” ANSI, DN 65 PN10, and JIS 10K 3B flanges
sticky materials
Power supply
148.8 mm (5.86”)
24 V DC, relay output 1 bolt hole
24 V DC, transistor output 2 circle diameter
100 to 230 V AC, relay output 3
Approvals
CE, C-TICK, INMETRO, ATEX II 2G EEx md IIC T5, C
SAA1) 190.2 mm (7.49”)
CE, C-TICK, CSA Class I, II, III, Div. 12) F diameter
CE, C-TICK, FM Class I, II, III, Div. 12) G
Pointek ULS200 Optional Flange Adapter
CE, C-TICK, CSAus/c, FM, 3A H
CE, C-TICK, CSA Class I, II, Div. 23) J ■ Dimensional drawings
Transducer/Process connection
ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1] A
EFTE, R 2" [(BSPT), EN 10226] B
EFTE, G 2" [(BSPP), EN ISO 228-1] C
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME E
B1.20.1]
5 PVDF copolymer, R 2" [(BSPT), EN 10226]
PVDF copolymer, G [(BSPP), EN ISO 228-1]
F
G
PVDF copolymer, 4" sanitary mounting, H
3A approved4)
Enclosure/cable inlet
Polycarbonate
• Cable inlet PG 13.5 1
• Cable inlet ½" NPT 2
Aluminum
• Cable inlet PG 13.5 3
• Cable inlet ½" NPT 4
Instruction manual
Additional Multi-language Quick Start manual C) 7ML1998-1XB82

This device is shipped with the Siemens Milltronics


manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
text line, suitable for enclosures
Universal Box Bracket Mounting Kit 7ML1830-1BK
3" ASME, DN 65, PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT
adapter for 2" NPT
3" ASME, DN 65, PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU
adapter for 2" BSPT
2" BSPT Locknut, plastic 7ML1830-1DQ
2" NPT Locknut 7ML1830-1DT
4" sanitary mounting clamp 7ML1830-1BR
Spare Parts
Polycarbonate Lid 7ML1830-1LG
Aluminum Lid 7ML1830-1LH
1)
Available with enclosure/cable inlet option 4 only
2)
Available with enclosure/cable inlet option 4 only and process connection
options A and E only
3) Pointek ULS200 dimensions
Available with enclosure/cable inlet options 2 and 4 only
4) Available with approval option H only
C) Subject to export regulations AL: N, ECCN: EAR99

5/106 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Point level measurement - Ultrasonic switch
Pointek ULS200

■ Schematics

Pointek ULS200 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/107


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transmitters
The Probe

■ Overview ■ Configuration

The Probe is a short-range integrated ultrasonic level transmitter,


ideal for liquids and slurries in open or closed vessels.

5 ■ Benefits
• Easy to install, program and maintain
• Accurate and reliable
• Sanitary models available
• Patented Sonic Intelligence® echo processing
• Integral temperature compensation

■ Application
The transducer is available in PVDF copolymer, making the de-
vice suitable for use in a wide variety of applications. The Probe
is easy to install and maintain, and can be quickly removed for
cleaning as required by the food, beverage and pharmaceutical
industries.
The reliability of the level data is based on the Sonic Intelligence
echo processing algorithms. A filter discriminates between the
true echo and false echoes from acoustic or electrical noises
and agitator blades in motion. The ultrasonic pulse propagation
time to the material and back is temperature-compensated and
converted into distance for display, analog output and relay
actuation.
• Key Applications: chemical storage vessels, filter beds, mud
pits, liquid storage vessels, food applications
The Probe mounting

5/108 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transmitters
The Probe

■ Technical specifications Selection and Ordering data Order No.


The Probe C) 7 M L 1 2 0 1 -
Three-wire version Two-wire version
(standard) Short-range integrated ultrasonic level transmitter, 777 0 0
ideal for liquids and slurries in open or closed ves-
Mode of operation sels
Measuring principle Ultrasonic level mea- Ultrasonic level mea- Measuring range
surement surement 5 m (16.40 ft) 1
Input Transducer/Process connection
Measuring range 0.25 to 5 m 0.25 to 5 m PVDF copolymer, 2" NPT [(Taper), ANSI/ASME E
(0.8 to 16.4 ft) (0.8 to 16.4 ft) B1.20.1]
PVDF copolymer, R 2" [(BSPT), EN 10226] F
Output PVDF copolymer, G 2" [(BSPP), EN ISO 228-1] G
• mA 4 to 20 mA 4 to 20 mA PVDF copolymer, 4" Sanitary mounting, 3A H
- Span Proportional/ Proportional/ approved
inversely proportional inversely proportional Model/Approval
- Max. load 750 Ω at 24 V DC 600 Ω in the loop at 3 Wire, 24 V DC, CE, C-TICK, CSA, FM E
24 V DC 2 Wire, 24 V DC, CE, C-TICK, CSA F

• Relay For level alarm or fault No Additional instruction manual


3 Wire, 24 V model, Multi-language manual C) 7ML1998-5GD61
Power supply 2 Wire model, Multi-language manual C) 7ML1998-5GC62
• Supply voltage 18 to 30 V DC, max. 12 to 28 V DC, 0.1 A This device is shipped with the Siemens Milltronics
0.2 A surge manual CD containing ATEX Quick Starts and
instruction manuals.
• Max. power con- 5 W (200 mA at 0.75 W (25 mA at
sumption
Certificates and
24 V DC) 24 V DC)
CE, C-TICK, CSAUS/C, CE, C-TICK, CSAUS/C,
Accessories
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC 5
text line suitable for enclosures
approvals FM, 3A 3A Universal Box Bracket Mounting kit 7ML1830-1BK
Sanitary 4" mounting clamp 7ML1830-1BR
Power Supply, 24 V DC, 200 mA for 2 probes C) 7ML1930-1AA
Accuracy (105 to 125 V AC input)
• Error in measurement 0.25 % of measuring range (in air) Power Supply, 24 V DC, 100 mA for 1 probe C) 7ML1930-1AB
(105 to 125 V AC input)
• Resolution 3 mm (0.125") 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT
• Temperature compensation Built in adapter for 2" NPT
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU
• Echo processing Sonic Intelligence
adapter for 2" BSPT
Rated operation conditions 2" NPT locknut, plastic 7ML1830-1DT
2" BSPT locknut, plastic 7ML1830-1DQ
• Beam angle 12°
Plastic M20 cable gland with metal locknut 7ML1930-1DB
• Ambient temperature SITRANS RD100 Remote display - see RD100 on
page 5/292
- Standard -40 to +60 °C (-40 to +140 °F)
SITRANS RD200 Remote display - see RD200 on
- Metallic mounting -20 to +60 °C (-4 to +140 °F) page 5/294
• Max. static operating pressure Normal atmospheric pressure C) Subject to export regulations AL: N, ECCN: EAR99
• Degree of protection IP65
Design
• Weight
- Without flange adapter 1.5 kg (3.3 lbs)
- With flange adapter 1.7 kg (3.7 lbs)
• Material
- Electronics enclosure PVC
- Transducer PVDF copolymer
• Degree of protection IP65
• Process connection 2" NPT [(Taper), ANSI/ASME
B1.20.1]
R 2" [(BSPT), EN 10226] or
G 2" [(BSPP), EN ISO 228-1]
• Flange adapter 3“ Universal, (fits DN 65, PN 10
and 3“ ASME)
4" sanitary
• Cable inlet 2 inlets for PG 13.5 or ½“ NPT
cable glands

March 2009 Siemens FI 01 · 2009 US Edition 5/109


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transmitters
The Probe

■ Options ■ Dimensional drawings


Flange adapter for mating 2” NPT or 2” BSP process connections
to 3” ANSI, DN 65 PN10, and JIS 10K 3B flanges

148.8 mm (5.86”)
bolt hole circle diameter

THE
PROBE

190.2 mm (7.49”)
diameter

The Probe Optional Flange Adapter

The Probe with Optional Mounting Bracket

■ Schematics

The Probe dimensions

The Probe connections

5/110 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transmitters
SITRANS Probe LU

■ Overview ■ Configuration

SITRANS Probe LU is a 2-wire loop powered ultrasonic transmit-


ter for level, volume and flow monitoring of liquids in open chan-
nels, storage vessels and simple process vessels.

■ Benefits 5
• Continuous level measurement up to 12 m (40 ft) range
• Easy installation and simple start-up
• Programming using infrared Intrinsically Safe handheld pro-
grammer, SIMATIC PDM or HART® Communicator
• Communication using HART or PROFIBUS PA
• ETFE or PVDF transducers for chemical compatibility
• Patented Sonic Intelligence signal processing
• Extremely high signal-to-noise ratio
• Auto False-Echo Suppression for fixed obstruction avoidance
• Level to volume or level to flow conversion

■ Application
The SITRANS Probe LU is ideal for level monitoring in the water
and wastewater industry and chemical storage vessels.
The range of SITRANS Probe LU is 6 or 12 m (20 or 40 ft). Using
Auto False-Echo Suppression for fixed obstruction avoidance,
as well as an improved signal-to-noise ratio and improved accu-
racy of 0.15% of range or 6 mm (0.25"), the Probe LU provides
unmatched reliability.
SITRANS Probe LU includes Sonic Intelligence® signal process- SITRANS Probe LU mounting
ing from the field-proven Probe and incorporates new echo pro-
cessing features and the latest micro-processor and communi-
cations technology. The Probe LU offers two communications
options: HART or PROFIBUS PA (Profile version 3.0, Class B).
The transducer on the Probe LU is available as ETFE or PVDF to
suit the chemical conditions of your application. As well, for ap-
plications with varying material and process temperatures, the
Probe LU incorporates an internal temperature sensor to com-
pensate for temperature changes.
• Key Applications: chemical storage vessels, filter beds, liquid
storage vessels

March 2009 Siemens FI 01 · 2009 US Edition 5/111


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transmitters
SITRANS Probe LU

■ Technical specifications Displays and Controls


Interface Local: LCD display with bar graph
Mode of operation
Remote: Available via HART or
Measuring principle Ultrasonic level measurement PROFIBUS PA
Typical application Level measurement in storage
vessels and simple process ves- Configuration Using Siemens SIMATIC PDM
sels (PC) or HART handheld communi-
cator or Siemens infrared hand-
Input held programmer
Measuring range Memory Non-volatile EEPROM
• 6 m (20 ft) model 0.25 to 6 m (10" to 20 ft) Power supply
• 12 m (40 ft) model 0.25 to 12 m (10" to 40 ft) 4 to 20 mA/HART Nominal 24 V DC with 550 Ω maxi-
mum; maximum 30 V DC
Frequency 54 kHz 4 to 20 mA
Output PROFIBUS PA 12, 13, 15, or 20 mA depending
mA/HART® on programming (General Pur-
pose or Intrinsically Safe version)
• Range 4 to 20 mA
per IEC 61158-2
• Accuracy ± 0.02 mA
Certificates and Approvals
PROFIBUS PA Profile 3, Class B
General CSAUS/C, FM, CE, C-TICK
Performance
Marine (only applies to HART com- • Lloyd’s Register of Shipping
Resolution ≤ 3 mm (0.12") munication option) • ABS Type Approval
Accuracy ± the greater of 0.15 % of range
5 or 6 mm (0.24") Hazardous
• Intrinsically Safe (Europe) ATEX II 1G EEx ia IIC T4
Repeatability ≤ 3 mm (0.12")
Blanking distance 0.25 m (10") • Intrinsically Safe (USA/Canada) CSA/FM (barrier required) T4,
Class I, Div. 1, Groups A, B, C, D;
Update time ≤ 5 seconds Class II, Div. 1, Groups E, F, G;
Class III
• 4/20 mA/HART version ≤ 5 seconds at 4 mA
• Intrinsically Safe (Australia/New ANZEx Ex ia IIC T4, Tamb = -40 to
• PROFIBUS version ≤ 4 seconds at 15 mA current Zealand) +80 °C (-40 to +176 °F) IP67, IP68
loop
• Intrinsically Safe (International) IECEx TSA 04.0020X Ex ia IIC T4
Temperature compensation Built-in to compensate over tem-
perature range • Non-incendive (USA) FM (no barrier required) T5: Class
I, Div. 2, Groups A,B,C, D
Beam angle 10°
Handheld Programmer
Rated operating conditions
• Intrinsically Safe Siemens hand- Infrared receiver
• Ambient conditions held programmer
- Location Indoor/outdoor - Approvals for handheld pro- IS model with ATEX EEx ia IIC T4
- Ambient temperature -40 to +80 °C (-40 to +176 °F) grammer CSA/FM Class I, Div. 1, Groups A,
- Relative humidity/ingress protec- Suitable for outdoor B, C, D
tion • Ambient temperature -20 to +40 °C (-5 to +104 °F)
- Installation category I • Interface Proprietary infrared pulse signal
- Pollution degree 4 • Power 3 V lithium battery (non-replace-
• Medium conditions able)

- Temperature at flange or threads -40 to +85 °C (-40 to +185 °F)


- Pressure (vessel) 0.5 bar g (7.25 psi g)
Design
Material (enclosure) PBT (Polybutylene Terephthalate)
Degree of protection Type 4X/NEMA 4X, Type 6/ NEMA
6/IP67/IP68 enclosure
Weight 2.1 kg (4.6 lbs)
Cable inlet 2 x M20x1.5 cable gland or 2 x ½"
NPT thread
Material (transducer) ETFE (Ethylene Tetrafluoroethyl-
ene) or PVDF (Polyvinylidene
Fluoride)
Process connection
• Threaded connection 2" NPT [(Taper), ANSI/ASME
B1.20.1]
R 2" [(BSPT), EN 10226] or
G 2" [(BSPP), EN ISO 228-1]
• Flange connection 3" (80 mm) universal flange
• Other connection FMS 200 mounting bracket (see
page 5/166) or customer supplied
mount

5/112 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transmitters
SITRANS Probe LU

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS Probe LU C) 7 M L 5 2 2 1 - SITRANS Probe LU C) 7 M L 5 2 2 1 -
2-wire, loop powered ultrasonic transmitter for 7 7 7 77 2-wire, loop powered ultrasonic transmitter for 7 7 7 77
level, volume and flow monitoring of liquids in open level, volume and flow monitoring of liquids in open
channels, storage vessels and simple process ves- channels, storage vessels and simple process ves-
sels. sels.
Enclosure/Cable Inlet Instruction manual for PROFIBUS PA device
Plastic (PBT), 2 x M20x1.5 (check Approvals for 1 English C) 7ML1998-5JB02
cable gland details) German C) 7ML1998-5JB32
Plastic (PBT), 2 x ½" NPT (no cable glands sup- 2 Note: The instruction manual should be ordered as
plied) a separate item on the order.
Range/Transducer material Additional Multi-language Quick Start manual C) 7ML1998-5QV81
6 meter (20 ft), ETFE A
6 meter (20 ft), PVDF Copolymer B This device is shipped with the Siemens Milltronics
12 meter (40 ft), ETFE C manual CD containing the complete ATEX Quick
12 meter (40 ft), PVDF Copolymer D Start and instruction manual library.
Process connection Optional equipment
2" NPT [(Taper), ANSI/ASME B1.20.1] A Handheld programmer, Intrinsically Safe, EEx ia 7ML5830-2AH
R 2" [(BSPT), EN 10226] B Handheld programmer, General Purpose approvals 7ML1830-2AN
G 2" [(BSPP), EN ISO 228-1] C
Handheld programmer, Infrared, Intrinsically Safe, 7ML5830-2AJ
Communication/Output PROFIBUS PA
4 to 20 mA, HART® 1
HART modem/RS-232 (for use with PC and D) 7MF4997-1DA
PROFIBUS PA 2 SIMATIC PDM)
Approvals HART modem/USB (for use with a PC and D) 7MF4997-1DB
General Purpose, FM, CSA, CE, C-TICK
Intrinsically Safe, FM Class I, Div. 1, Groups A, B,
1
2
SIMATIC PDM)
2" NPT locknut, plastic 7ML1830-1DT
5
C, D (barrier required); Class II, Div. 1, Groups E, F, 2" BSPT locknut, plastic 7ML1830-1DQ
G; Class III; ATEX II 1G EEx ia IIC T4, ANZEx,
IECEx (HART model only) 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT
Intrinsically Safe, CSA Class I, Div. 1, Groups A, B, 3 adapter for 2" NPT
C, D (barrier required); Class II, Div. 1, Group G; 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU
Class III (HART model only) adapter for 2" BSPT
FM, Class l, Div. 2 (Enclosure option 2 only) 4 One General Purpose polymeric cable gland 7ML1930-1AM
Intrinsically Safe, CSA/FM Class I, Div. 1, Groups A, 5 M20x1.5, rated for -20 to +80 °C (-4 to +176 °F)
B, C, D (barrier required); Class II, Div. 1, Groups E, One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
F, G; Class III (PROFIBUS PA model only) +80 °C (-40 to +176 °F) for General Purpose or
Intrinsically Safe, ATEX II 1G EEx ia IIC T4 6 ATEX EEx e installations (available for HART only)
(PROFIBUS PA model only) One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
+80 °C (-40 to +176 °F) with integrated shield con-
Further designs Order code nection (available for PROFIBUS PA)
Please add “-Z" to Order No. and specify Order SITRANS RD100 Remote display - see RD100 on
code(s). page 5/292
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15 SITRANS RD200 Remote display - see RD200 on
Measuring-point number/identification (max. 16 page 5/294
characters) specify in plain text Spare Parts
Instruction manual for HART/mA device Plastic lid C) 7ML1830-1KB
English C) 7ML1998-5HT02
French C) 7ML1998-5HT11 C) Subject to export regulations AL: N, ECCN: EAR99
German C) 7ML1998-5HT32 D) Subject to export regulations AL: N, ECCN: EAR99H
Note: The instruction manual should be ordered as
a separate item on the order.
Additional Multi-language Quick Start manual C) 7ML1998-5QR81

This device is shipped with the Siemens Milltronics


manual CD containing the complete ATEX Quick
Start and instruction manual library.

■ Options
Flange adapter for mating 2” NPT or 2” BSP process connections
to 3” ANSI, DN 65 PN10, and JIS 10K 3B flanges

148.8 mm (5.86”)
bolt hole
circle diameter

190.2 mm (7.49”)
diameter

SITRANS Probe LU optional flange adapter


SITRANS Probe LU with optional mounting bracket

March 2009 Siemens FI 01 · 2009 US Edition 5/113


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transmitters
SITRANS Probe LU

■ Dimensional drawings

SITRANS Probe LU dimensions

■ Schematics

SITRANS Probe LU connections

5/114 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger 200

■ Overview ■ Application
For water authorities, municipal water and wastewater plants,
HydroRanger 200 is an economical, low-maintenance solution
delivering control efficiency and productivity needed to meet to-
day’s exacting standards. It offers single point monitoring with all
models, and optional dual-point monitoring with 6 relay model.
As well, it has digital communications with built-in Modbus RTU
via RS-485.
The standard 6 relay HydroRanger 200 will monitor open chan-
nel flow and features more advanced relay alarming and pump
control functions as well as volume conversion. It is compatible
with SIMATIC PDM, allowing for PC configuration and setup.
Sonic Intelligence® advanced echo-processing software pro-
vides increased reading reliability. The optional 1 or 3 relay mod-
els provide accurate level measurement functions only; these
two models do not provide open channel flow, differential level
measurement or volume conversion functions.
HydroRanger 200 uses proven continuous ultrasonic echo rang-
ing technology to monitor water and wastewater of any consis-
tency up to 15 m (50 ft) in depth. Achievable resolution is 0.1%
with accuracy to 0.25% of range. Unlike contacting devices,
HydroRanger 200 is immune to problems caused by suspended
solids, harsh corrosives, grease or silt in the effluent, reducing
downtime.
• Key Applications: wet wells, flumes/weirs, bar screen control
5
HydroRanger 200 is an ultrasonic level controller for up to six
pumps and provides control, differential control and open chan-
nel flow monitoring.

■ Benefits
• Monitors wet wells, weirs and flumes
• Digital communications with built-in Modbus RTU via RS-485
• Compatible with SmartLinx system and SIMATIC PDM config-
uration software
• Single or dual point level monitoring
• 6 relay (standard), 1 or 3 relay (optional)
• Auto False-Echo Suppression for fixed obstruction avoidance
• Anti-grease ring/tide mark buildup
• Differential amplifier transceiver for common mode noise re-
jection and improved signal-to-noise ratio
• Wall and panel mounting options

March 2009 Siemens FI 01 · 2009 US Edition 5/115


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger 200

■ Technical specifications Design


Weight
Mode of Operation
• Wall mount 1.37 kg (3.02 lbs)
Measuring principle Ultrasonic level measurement
• Panel mount 1.50 kg (3.31 lbs)
Measuring range 0.3 to 15 m (1 to 50 ft), transducer
dependent Material (enclosure) Polycarbonate
Measuring points 1 or 2 Degree of protection (enclosure)
Input • Wall mount IP65/Type 4X/NEMA 4X
Analog 0 to 20 mA or 4 to 20 mA, from • Panel mount IP54/Type 3/NEMA 3
alternate device, scaleable (6
relay model) Cable

Discrete 10 to 50 V DC switching level Transducer and mA output signal 2-core copper conductor, twisted,
Logical 0 = < 0.5 V DC shielded, 300 Vrms, 0.82 mm²
Logical 1 = 10 to 50 V DC (18 AWG), Belden® 8760 or
Max. 3 mA equivalent is acceptable

Output Max. separation between trans- 365 m (1200 ft)


ducer and transceiver
Echomax® transducer 44 kHz
Displays and controls 100 x 40 mm (4 x 1.5") multi-block
Ultrasonic transducer Compatible transducers: ST-H LCD with backlighting
and Echomax series XPS-10/10F,
XPS 15/15F, XCT-8, XCT-12 and Programming Programming using handheld
XRS-5 programmer or via PC with
SIMATIC PDM software
Relays1) Rating 5 A at 250 V AC, non-
Power supply4)
5 - Model with 1 relay2)
inductive
1 SPST Form A AC version 100 to 230 V AC ± 15%, 50/60 Hz,
36 VA (17 W)
- Model with 3 relays2) 2 SPST Form A/1 SPDT Form C
DC version 12 to 30 V DC (20 W)
- Model with 6 relays 4 SPST Form A/2 SPDT Form C
Certificates and approvals • CE, C-TICK5)
mA output 0 to 20 mA or 4 to 20 mA • Lloyd’s Register of Shipping
• Max. load 750 Ω, isolated • ABS Type Approval
• Resolution 0.1 % of range • FM, CSANRTL/C, UL listed
Accuracy • CSA Class I, Div. 2, Groups A, B,
C and D, Class II, Div. 2, Groups
Error in measurement 0.25% of range or 6 mm (0.24"), F and G, Class III (wall mount
whichever is greater only)
Resolution 0.1% of measuring range or 2 mm • MCERTS Class 1 approved for
(0.08"), whichever is greater3) Open Channel Flow
Temperature compensation • -50 to +150 °C (-58 to +302 °F) Communication • RS-232 with Modbus RTU or
• Integral temperature sensor in ASCII via RJ-11 connector
transducer • RS-485 with Modbus RTU or
• External TS-3 temperature sen- ASCII via terminal blocks
sor (optional) • Optional: SmartLinx® cards for
• Programmable fixed tempera- - PROFIBUS DP
ture values - DeviceNetTM
Rated operating conditions - Allen-Bradley® Remote I/O
Installation conditions 1)
All relays certified for use with equipment that fails in a state at or under the
Location indoor / outdoor rated maximums of the relays
2) This model is level control only; no open channel flow, differential level or
Installation category II volume conversion functions
3)
Program range is defined as the empty distance to the face of the trans-
Pollution degree 4
ducer plus any range extension
4)
Ambient conditions Maximum power consumption is listed
5)
EMC performance available upon request
Ambient temperature (enclosure) -20 to +50 °C (-4 to +122 °F)

5/116 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger 200

Selection and Ordering data Order No. Selection and Ordering data Order No.
Siemens HydroRanger 200 C) 7 M L 5 0 3 4 - Siemens HydroRanger 200 C) 7 M L 5 0 3 4 -
Ultrasonic level controller for up to six pumps that Ultrasonic level controller for up to six pumps that
77 7 77 77 7 77
provides control, differential control and open provides control, differential control and open
channel flow monitoring. The HydroRanger 200 is channel flow monitoring. The HydroRanger 200 is
also available as a level measurement controller also available as a level measurement controller
only. Select option from model code below. only. Select option from model code below.
Mounting Accessories
Wall mount, standard enclosure 1 Handheld programmer 7ML1830-2AK
Wall mount, 4 entries, 4 M20 cable glands included 2 Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
Panel mount1) 3 text line, suitable for enclosure
Power supply TS-3 Temperature Sensor - see TS-3 on page 5/167
100 to 230 V AC A SITRANS RD100 Remote display - see RD100 on
12 to 30 V DC B page 5/292
SITRANS RD200 Remote display - see RD200 on
Number of measurement points page 5/294
Single point model, 6 relays A
Spare parts
Dual point model, 6 relays B
Power Supply Board (100 to 230 V AC) C) 7ML1830-1MD
Single point model, level only, 1 relay2) C
Power Supply Board (12 to 30 V DC) C) 7ML1830-1ME
Single point model, level only, 3 relays2) D
Display Board C) 7ML1830-1MF
Communication (SmartLinx)
See SmartLinx product page 5/289 for more infor-
Without module 0 mation.
SmartLinx® Allen-Bradley® Remote I/O module 1
1)
SmartLinx PROFIBUS DP module 2 Available with approval option 1 only
SmartLinx DeviceNetTM module
See SmartLinx product page 5/289 for more infor-
3
2)
This model is level control only; no open channel flow, differential level, or
volume conversion functions 5
C) Subject to export regulations AL: N, ECCN: EAR99
mation.
Approvals
General Purpose CE, FM, CSAUS/C, UL listed, 1
C-TICK
CSA Class I, Div. 2, Groups A, B, C and D; Class II, 2
Div 2, Groups F and G; Class III (for wall mount
applications only)
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
English C) 7ML1998-5FC02
French C) 7ML1998-5FC11
German C) 7ML1998-5FC32
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Other instruction manuals
SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33

SmartLinx PROFIBUS DP, French C) 7ML1998-1AQ12


SmartLinx DeviceNet, English C) 7ML1998-1BH02
Note: The appropriate SmartLinx instruction manual
should be ordered as a separate line on the order.

March 2009 Siemens FI 01 · 2009 US Edition 5/117


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger 200

Selection and Ordering data Order No. Selection and Ordering data Order No.
Milltronics HydroRanger 200 C) 7 M L 1 0 3 4 - Milltronics HydroRanger 200 C) 7 M L 1 0 3 4 -
Ultrasonic level controller for up to six pumps that Ultrasonic level controller for up to six pumps that
77 7 77 77 7 77
provides control, differential control and open provides control, differential control and open
channel flow monitoring. The HydroRanger 200 is channel flow monitoring. The HydroRanger 200 is
also available as a level measurement controller also available as a level measurement controller
only. Select option from model code below. only. Select option from model code below.
Mounting Accessories
Wall mount, standard enclosure 1 Handheld programmer 7ML1830-2AK
Wall mount, 4 entries, 4 M20 cable glands included 2 Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
Panel mount1) 3 text line, suitable for enclosure
Power supply TS-3 Temperature Sensor - see TS-3 on page 5/167
100 to 230 V AC A SITRANS RD100 Remote display - see RD100 on
12 to 30 V DC B page 5/292
Communication (SmartLinx) SITRANS RD200 Remote display - see RD200 on
page 5/294
Without module A
SmartLinx® Allen-Bradley® Remote I/O module B Spare parts
SmartLinx PROFIBUS DP module C Power Supply Board (100 to 230 V AC) C) 7ML1830-1MD
TM Power Supply Board (12 to 30 V DC) C) 7ML1830-1ME
SmartLinx DeviceNet module D
See SmartLinx product page 5/289 for more infor- Display Board C) 7ML1830-1MF
mation. See SmartLinx product page 5/289 for more infor-
Approvals mation.
General Purpose CE, FM, CSAUS/C, UL listed, 1 1)
Available with approval option 1 only
5 C-TICK
CSA Class I, Div. 2, Groups A, B, C and D; Class II, 2
2)
This model is level control only; no open channel flow, differential level, or
volume conversion functions
Div 2, Groups F and G; Class III (for wall mount C) Subject to export regulations AL: N, ECCN: EAR99
applications only)
®
Number of measurement points Modbus is a registered trademark of Schneider Electric.
®Belden is a registered trademark of Belden Wire and Cable Company.
Single point model, 6 relays 1 ®Allen-Bradley is a registered trademark of Rockwell Automation.
Dual point model, 6 relays 2 TMDeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA)
Single point model, level only, 1 relay2) 3
Single point model, level only, 3 relays2) 4
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification
(max. 16 characters) specify in plain text
Instruction manual Order No.
English C) 7ML1998-1FC05
French C) 7ML1998-1FC14
German C) 7ML1998-1FC34
Note: The instruction manual should be ordered as
a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Other instruction manuals
SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33

SmartLinx PROFIBUS DP, French C) 7ML1998-1AQ12


SmartLinx DeviceNet, English C) 7ML1998-1BH02
Note: The appropriate SmartLinx instruction manual
should be ordered as a separate line on the order.

5/118 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger 200

■ Dimensional drawings ■ Schematics

See note 1

DC version

DISCRETE
INPUTS

Relays shown in released state

Notes 5
1. Use 2-core copper wire, twisted, with shield, for expansion up to 365 m (1200 ft.).
Route cable in grounded metal conduit, separate from other cables.
2. Verify that all system components are installed in accordance with instructions.
3. Connect all cable shields to the HydroRanger 200 Shield Connections. Avoid differential
ground potentials by not connecting cable shields to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible to reduce noise
on the line caused by stray transmissions and noise pickup.

HydroRanger 200 connections

HydroRanger 200 dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/119


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
MultiRanger 100/200

■ Overview

MultiRanger is a versatile short to medium-range ultrasonic sin-


gle and multi-vessel level monitor/controller for virtually any ap-
plication in a wide range of industries.

5 ■ Benefits
• Digital input for back-up level overide from point level device
• Communication using built-in Modbus RTU via RS-485
• Compatible with SmartLinx system and SIMATIC PDM config-
uration software
• Single or dual point level monitoring
• Auto False-Echo Suppression for fixed obstruction avoidance
• Differential amplifier transceiver for common mode noise re-
duction and improved signal-to-noise ratio
• MultiRanger 100: level measurements, simple pump control
and level alarm functions
• MultiRanger 200: level, volume and flow measurements in
open channels, differential control, extended pump control
and alarm functions
• Wall and panel mounting options

■ Application
MultiRanger can be used on different materials, including fuel
oil, municipal waste, acids, woodchips or on materials with high
angles of repose. MultiRanger offers true dual point monitoring,
digital communications with built-in Modbus® RTU via RS-485,
as well as compatibility with SIMATIC PDM, allowing PC config-
uration and setup. MultiRanger features Sonic Intelligence® ad-
vanced echo-processing software for increased reading reliabil-
ity.
MultiRanger 100 offers cost-effective level alarming, as well as
on/off and alternating pump control. MultiRanger 200 will monitor
open channel flow and features more advanced relay alarming
and pump control functions as well as volume conversion.
It is compatible with chemical-resistant Echomax® transducers
that can be used in hostile environments at temperatures as high
as +145 °C (+293 °F).
• Key Applications: wet wells, flumes/weirs, bar screen control,
hoppers, chemical storage, liquid storage, crusher bins, dry
solids storage

■ Design
The MultiRanger is available in wall or panel mounting options.

5/120 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
MultiRanger 100/200

■ Technical specifications Design


• Weight
Mode of Operation
- Wall mount 1.37 kg (3.02 lbs)
Measuring principle Ultrasonic level measurement
- Panel mount 1.50 kg (3.31 lbs)
Measuring range 0.3 to 15 m (1 to 50 ft)
• Material (enclosure) Polycarbonate
Measuring points 1 or 2
• Degree of protection (enclosure)
Input
- Wall mount IP65/Type 4X/NEMA 4X
• Analog (MultiRanger 200 only) 0 to 20 mA or 4 to 20 mA, from
alternate device, scaleable - Panel m IP54/Type 3/NEMA 3
• Discrete 10 to 50 V DC switching level - ount
Logical 0 =< 0.5 V DC Electrical connection
Logical 1 = 10 to 50 V DC
Max. 3 mA • Transducer and mA output signal 2-core copper conductor, twisted,
shielded, 0.5 to 0.75 mm² (22 to
Output 18 AWG), Belden® 8760 or equiv-
• Echomax® transducer 44 kHz alent is acceptable
• Ultrasonic transducer Compatible transducers: ST-H • Max. separation between trans- 365 m (1200 ft)
and Echomax series XPS-10/10F, ducer and transceiver
XPS 15/15F, XCT-8, XCT-12 and Displays and controls 100 x 40 mm (4 x 1.5") multi-block
XRS-5 LCD with backlighting
• Relays Rating 5 A at 250 V AC, non- • Programming Programming using hand-held
inductive programmer, SIMATIC PDM or via
- Version with 1 relay (MultiRanger 1 SPST Form A PC with Dolphin Plus software
100 only) Power supply 5
- Version with 3 relays 2 SPST Form A/1 SPDT Form C • AC version 100 to 230 V AC ± 15 %,
- Version with 6 relays 4 SPST Form A/2 SPDT Form C 50/60 Hz, 36 VA (17 W)
• mA output 0 to 20 mA or 4 to 20 mA • DC version 12 to 30 V DC (20 W)
- Max. load 750 Ω, isolated Certificates and approvals • CE2)
- Resolution 0.1% of range • Lloyd’s Register of Shipping
• ABS Type Approval
Accuracy
• FM, CSANRTL/C, UL listed
• Error in measurement 0.25% of range or 6 mm (0.24"),
• CSA Class I, Div. 2, Groups A, B,
whichever is greater
C and D, Class II, Div.2, Groups
• Resolution 0.1 % of measuring range1) F and G, Class III (wall mount
or 2 mm (0.08"), whichever is only), ATEX II 3D
greater Communication • RS-232 with Modbus RTU or
• Temperature compensation • -50 to +150 °C (-58 to +302 °F) ASCII via RJ-11 connector
• Integral temperature sensor • RS-485 with Modbus RTU or
ASCII via terminal strips
• External TS-3 temperature sen-
sor (optional) • Optional: SmartLinx® cards for
• Programmable fixed tempera- - PROFIBUS DP
ture values - DeviceNetTM
Rated operating conditions - Allen-Bradley® Remote I/O
1)
Installation conditions Program range is defined as the empty distance to the face of the trans-
ducer plus any range extension
• Location Indoor/outdoor 2) EMC performance available on request
• Installation category II
• Pollution degree 4
Ambient conditions
• Ambient temperature (housing) -20 to +50 °C (-4 to +122 °F)

March 2009 Siemens FI 01 · 2009 US Edition 5/121


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
MultiRanger 100/200

Selection and Ordering data Order No. Selection and Ordering data Order No.
MultiRanger 100/200 L) 7 M L 5 0 3 3 - MultiRanger 100/200 L) 7 M L 5 0 3 3 -
Versatile short to medium-range ultrasonic single Versatile short to medium-range ultrasonic single
7 7 7 77 - 77 7 7 7 77 - 77
and multi-vessel level monitor/controller for virtually and multi-vessel level monitor/controller for virtually
any application in a wide range of industries any application in a wide range of industries
Versions Instruction manual
MultiRanger 100, level measurement only 1 English C) 7ML1998-5FB06
MultiRanger 200, level, volume, flow and differential 2 French C) 7ML1998-5FB13
measurements Spanish C) 7ML1998-5FB23
Mounting, enclosure design German C) 7ML1998-5FB34
Wall mount, standard enclosure A
Quick Start guide, multi-language C) 7ML1998-5QD83
Wall mount, 4 entries, 4 M20 cable glands included B Note: The instruction manual should be ordered as
Panel mount (CE, CSAUS/C, FM, UL) C a separate line on the order.
Power supply This device is shipped with the Siemens Milltronics
100 to 230 V AC A manual CD containing the complete ATEX Quick
12 to 30 V DC B Start and instruction manual library.
Number of measurement points Other instruction manuals
Single point version 0 SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
Dual point version 1 SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33
Communication (SmartLinx)
Without module 0 SmartLinx PROFIBUS DP, French C) 7ML1998-1AQ12
SmartLinx® Allen-Bradley® Remote I/O 1 SmartLinx DeviceNet, English C) 7ML1998-1BH02
module Note: The appropriate SmartLinx instruction manual

5 SmartLinx PROFIBUS DP module 2 should be ordered as a separate line on the order.


SmartLinx DeviceNetTM module 3 Accessories
See SmartLinx product page 5/289 for more infor- Handheld programmer 7ML1830-2AK
mation. Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
Output relays text line, suitable for enclosure
3 relays (2 Form A, 1 Form C), 250 V AC 1 TS-3 Temperature Sensor - see TS-3 on page 5/167
6 relays (4 Form A, 2 Form C), 250 V AC 2 SITRANS RD100 Remote display - see RD100 on
1 relay (1 Form A), 250 V AC (available on 3 page 5/292
MultiRanger 100 model only) SITRANS RD200 Remote display - see RD200 on
page 5/294
Approvals
General Purpose CE, FM, CSAUS/C, UL listed, A Spare parts
C-TICK Power Supply Board (100 to 230 V AC) C) 7ML1830-1MD
CSA Class I, Div. 2, Groups A, B, C and D; Class II, B Power Supply Board (12 to 30 V DC) C) 7ML1830-1ME
Div 2, Groups F and G; Class III1) Display Board C) 7ML1830-1MF
ATEX II 3D2) C See SmartLinx product page 5/289 for more infor-
Further designs Order code mation.
Please add “-Z" to Order No. and specify Order 1)
For wall mount applications only
code(s). 2)
For standard enclosure wall mount, option A only
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15 L) Subject to export regulations AL: N, ECCN: 3A991X
Measuring-point number/identification (max. 16 ®
Modbus is a registered trademark of Schneider Electric.
characters) specify in plain text ®
Belden is a registered trademark of Belden Wire and Cable Company.
®Allen-Bradley is a registered trademark of Rockwell Automation.

TM
DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA)

5/122 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
MultiRanger 100/200

■ Dimensional drawings ■ Schematics

See note 1

DC version

DISCRETE
INPUTS

Relays shown in released state

Notes 5
1. Use 2-core copper wire, twisted, with shield, for expansion up to 365 m (1200 ft.).
Route cable in grounded metal conduit, separate from other cables.
2. Verify that all system components are installed in accordance with instructions.
3. Connect all cable shields to the MultiRanger Shield Connections. Avoid differential
ground potentials by not connecting cable shields to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible to reduce noise
on the line caused by stray transmissions and noise pickup.

MultiRanger connections

MultiRanger dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/123


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger Plus

■ Overview Output
• Ultrasonic transducer 44 kHz
• Relays 5 alarm/control relays, 1 SPDT
Form C per relay, rated 5 A at
250 V AC, resistive load
• mA output 0/4 to 20 mA, optically isolated
- Max. load 1 kΩ
- Resolution 0.1 % of 20 mA
Accuracy
• Error in measurement 0.25% of range or 6 mm (0.24“),
whichever is greater
• Resolution 0.1% of measuring range or 2 mm
(0.08"), whichever is greater1)
• Temperature compensation -50 to +150 °C (-58 to +302 °F)
• Integral temperature sensor
• External TS-3 temperature sen-
sor (optional)
• Programmable fixed tempera-
HydroRanger Plus is an ultrasonic level controller for control of ture
wet wells and reservoir pump operations, differential control and
Rated operating conditions
open channel flow monitoring, using energy-saving algorithms.
Ambient conditions
5 ■ Benefits • Ambient temperature for enclosure -20 to +50 °C (-4 to +122 °F)
• Outputs for alarms, chart recorders, controllers and integra- Design
tion of existing systems • Rack mount DIN 3 HU/14 pitch, 4 rail plug-in
• Monitors wet wells, weirs and flumes unit suitable for standard 84 pitch
(19") rack
• Energy-saving function with built-in real-time clock
• Panel mount Suitable for standard panel cutout
• Special control mode to reduce grease rings and other depos- DIN 43700, 72 x 144 mm, 100 mm
its center height
• Integral temperature compensation • Degree of protection (wall mount) IP65/NEMA 4X/Type 4X
• Pump performance monitoring • Weight (rack and panel mount) 0.87 kg (1.9 lbs)
• System monitoring and network analysis • Weight (wall mount) 1.5 kg (3.3 lbs)

■ Application • Material (enclosure) Polyester/polycarbonate alloy


Electrical connection Commercially available copper
The system is effective in wet wells, weirs, and flumes where conductor according to local
foam and turbulence are typical operating conditions. It can be requirements, rated 250 V/5 A
customized to meet your specific application needs – from mea- • Ultrasonic transducer cable exten- RG 62-A/U coaxial cable with low
suring flow rate in a narrow flume to volume in a ferric chloride sion capacitance
storage bank.
• mA output signal 2-core copper conductor, twisted,
The system consists of the electronics housed in a wall-mounted shielded, 0.5 to 0.75 mm² (22 to
enclosure and a hermetically sealed, corrosion-resistant 18 AWG), Belden® 8760 or equiv-
Echomax® transducer. These components can be separated by alent is acceptable
up to 365 m (1200 ft). Power supply 100/115/200/230 V AC, ± 15%,
50/60 Hz, 15 VA and/or
Optional submergence shields ensure consistent operation in
wet wells where the transducer may be submerged during flood- 9 to 30 V DC, 8 W
ing from rainfall or a power outage. Siemens patented detection • Ultrasonic transducer Compatible transducers: ST-H
software can differentiate between a submerged condition and and Echomax series XPS-10/10F,
a high level. XPS 15/15F, XCT-8, XCT-12 and
XRS-5
• Key Applications: wet wells, weirs, flumes
Displays and controls
Rack and panel mount 75 x 20 mm (3 x 0.8") LCD (select-
able backlighting)
■ Technical specifications Wall mount 100 x 40 mm (4 x 1.5") multifield
Mode of operation LCD, backlit
Measuring principle Ultrasonic level measurement Programming Removable programmer or
optional Dolphin Plus
Measuring range 0.3 to 15 m (1 to 50 ft)
Memory EEPROM (non-volatile), no
Measuring points 1 or 2 backup battery required
Certificates and approvals CE2), FM, CSANRTL/C, C-TICK
1) The measuring range corresponds to the distance from the zero point to the
sensor face, plus any range extension.
2)
EMC certificate available on request
®
Belden is a registered trademark of Belden Wire and Cable Company.

5/124 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger Plus

Selection and Ordering data Order No. Selection and Ordering data Order No.
HydroRanger Plus, rack and panel mount C) 7 M L 1 0 2 5 - HydroRanger Plus, wall mount C) 7 M L 1 0 2 8 -
Non-contacting ultrasonic echo ranging technology 777 0 1 Non-contacting ultrasonic echo ranging technology 7A77 0
monitor that comes standard with a backlit display monitor that comes standard with a backlit display
Measuring range: 0.3 m to 15 m (1 to 50 ft) Measuring range: 0.3 m to 15 m (1 to 50 ft)
Mounting/device version Input voltage
Version for 19" rack (requires terminal block; see 1 100 V AC, 9 to 30 V DC 1
accessories) 115 V AC, 9 to 30 V DC 2
Version for panel 2
200 V AC, 9 to 30 V DC 3
Approvals 230 V AC, 9 to 30 V DC 4
CE (EN 61326), CSANRTL/C, FM, C-TICK C
Approvals
Input voltage CE; FM General Purpose; CSA Class I, Div. 2, C
100 V AC, 9 to 30 V DC A C-TICK
115 V AC, 9 to 30 V DC B Mounting/enclosure version
200 V AC, 9 to 30 V DC C Standard enclosure (NEMA 4X) 1
230 V AC, 9 to 30 V DC D Standard enclosure prepared for five M20 cable 3
glands
Further designs Order code
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s). Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16 Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
characters) specify in plain text
Instruction manual Order No.
Measuring-point number/identification (max. 16
characters) specify in plain text 5
English C) 7ML1998-1AC02 Instruction manual Order No.
French C) 7ML1998-1AC12 English C) 7ML1998-1AC02
German C) 7ML1998-1AC32 French C) 7ML1998-1AC12
Note: The instruction manual should be ordered as German C) 7ML1998-1AC32
a separate line item on the order. Note: The instruction manual should be ordered as
a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick This device is shipped with the Siemens Milltronics
Start and instruction manual library. manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Handheld programmer 7ML1830-2AC Accessories
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC Handheld programmer 7ML1830-2AC
text line suitable for enclosures Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one 7ML1930-1AC
Terminal block for rack mount 7ML1830-1JL text line suitable for enclosures
TS-3 Temperature Sensor - see TS-3 on page 5/167 M20 cable gland kit (6 M20 cable glands, 6 M20 7ML1830-1GM
SITRANS RD100 Remote display - see RD100 on nuts, 3 stop plugs)
page 5/292 TS-3 Temperature Sensor - see TS-3 on page 5/167
SITRANS RD200 Remote display - see RD200 on SITRANS RD100 Remote display - see RD100 on
page 5/294 page 5/292
Spare parts SITRANS RD200 Remote display - see RD200 on
Card, Analog HydroRanger Plus Rack/Panel C) 7ML1830-1LR page 5/294
Card, daughter C) 7ML1830-1LS Spare parts
Card, display, backlit C) 7ML1830-1LX Card, mother main C) 7ML1830-1LV
Card, daughter C) 7ML1830-1LW
C) Subject to export regulations AL: N, ECCN: EAR99
Card, display C) 7ML1830-1LU

C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/125


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger Plus

■ Dimensional drawings ■ Schematics

HydroRanger Plus dimensions HydroRanger Plus connections, rack and panel mount

5/126 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
HydroRanger Plus

HydroRanger Plus connections, wall mount


5

March 2009 Siemens FI 01 · 2009 US Edition 5/127


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LUC500

■ Overview Application of accessories


SITRANS LUC500 can be expanded to meet the requirements of
a variety of applications.
Auxiliary I/O cards, RAM and data logging, dual-channel func-
tion and SmartLinx communications.
• Input/output cards
A single auxiliary I/O card can be installed in the SITRANS
LUC500. The following I/O cards are available:
- 2 analog inputs/2 analog outputs
- 4 analog inputs
- 4 analog outputs
- 8 digital inputs
- 8 digital inputs/2 analog inputs/2 analog outputs (wall mount
only)
• Expanded memory card
The available RAM can be increased using this card. The data
logging function is then available.
• Two-channel function
A second measuring point is provided on the SITRANS
LUC500 to permit dual-channel measurements. This function
SITRANS LUC500 is a complete ultrasonic level controller for is made available by ordering a software access code. Please
monitoring and control of water distribution and wastewater col- contact your Siemens representative for details.
lection systems, with energy-saving algorithms.
• Communications
5 ■ Benefits
The SITRANS LUC500 is offered with MODBUS RTU/ASCII as
a standard feature. Further industrial communications proto-
• Monitoring and control in one device cols are available with the addition of an optional SmartLinx
card. The following protocols are currently available:
• Integral telemetry interface (Modbus RTU/ASCII) - PROFIBUS DP
• Patented algorithm for calculation of pumped volume within - Allen Bradley® Remote I/O
5% accuracy - DeviceNet™
• Logging of pump runtime and number of pump starts ®
Modbus is a registered trademark of Schneider Electric.
®
• Expandable with I/Os, RAM for data logging, dual point, Allen-Bradley is a registered trademark of Rockwell Automation.
TM
SmartLinx communications and RS-485 interface DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA)
®
Windows is a registered trademark of Microsoft Corp.
• Simple system configuration and diagnostics with Siemens
Dolphin Plus Windows®-based software
• AC or DC power supply
• SITRANS LUC500 is available for rack mount, panel mount or
wall mount

■ Application
It combines non-contacting ultrasonic technology, patented
echo-processing techniques and proven application software to
provide accurate level monitoring in liquids up to 15 m (50 ft). It
also effectively monitors flow in flumes, weirs and open chan-
nels. Five relays control any combination of pumps, gate valves
and alarms. Further advantages include fault signalling and data
logging for trend analysis. It can log the time, date and volume
of up to 20 occurrences of combined sewer overflows (CSO).
The basic device has 8 digital inputs, 5 digital outputs, 1 analog
input, 1 ultrasonic level point, differential/average capability and
one RS-232 interface with Modbus® RTU/ASCII protocol. The
device can be expanded by additional I/Os, more RAM, two
channels, RS-485 or SmartLinx communications models as your
needs grow.
It integrates seamlessly with SCADA or DCS systems or a PLC
system to provide remote access to all system parameters
(pumped volume, pump runtime, pump status). The integral te-
lemetry interface (Modbus RTU/ASCII) allows remote control in
real time.
• Key Applications: wet well/lift station control, weirs/flumes,
open channels

5/128 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LUC500

■ Technical specifications Selection and Ordering data Order No.


SITRANS LUC500 L) 7 M L 5 0 0 1 -
Mode of operation A complete ultrasonic level controller for monitoring
and control of water distribution and wastewater 7 7 7 77 - 77 A 7
Measuring principle Ultrasonic level measurement
Measuring range 0.3 to 15 m (1 to 50 ft) collection systems, with energy-saving algorithms.
Measuring points 1 or 2 Mounting
Output Panel mount version 1
Rack mount version for 19" rack 2
Ultrasonic transducer 44 kHz Wall mount, standard enclosure 3
Relays 5 relays, rated 5 A at 250 V AC, Wall, 4 entry, M20 (valid with approval option 3 only) 5
non-inductive
• Wall Mount version: 4 SPST Input voltage
Form A relays, 1 SPDT Form C 100 to 230 V AC A
relay 12 to 30 V DC B
• Rack and Panel Mount version:
4 SPST Form A relays, 1 SPST Number of measurement points
Form B relay Single point version A
Accuracy Dual point version B
Error in measurement 0.25% of range or 6 mm (0.24"), Data communications
whichever is greater SmartLinx ready, no module 0
Resolution 0.1% of measuring range or 2 mm SmartLinx PROFIBUS DP module 1
(0.08"), whichever is greater1) SmartLinx Allen-Bradley Remote I/0 module 2
Temperature compensation -50 to +150 °C (-58 to +302 °F) SmartLinx DeviceNet module 3
• Integral temperature sensor
5
Protocol
• External TS-3 temperature sen-
sor (optional) Modbus RTU/ASCII 1
• Programmable fixed tempera- Auxilliary memory
ture None 0
Rated operating conditions 1 Mbyte static RAM, including data logging module 1
Ambient conditions Auxilliary I/O
Ambient temperature for enclosure -20 to +50°C (-4 to +122 °F) None A
2 analog inputs and 2 analog outputs B
Design
4 analog inputs C
• Rack mount DIN 3 HU/21 pitch, 4-rail plug-in
4 analog outputs D
unit suitable for standard 3 HU/84
pitch (19") rack 8 digital inputs E
8 digital inputs, 2 analog inputs and 2 analog out- F
• Panel mount Suitable for standard panel cutout puts (only for wall mount)
DIN 43700 72 x 144 mm, 110 mm
(4.33") center height Approvals
CSA, CE, UL (not available with mounting option 5) 2
Weight (rack and panel mount) 1.5 kg (3.3 lbs)
CE 3
Weight (wall mount) 2.5 kg (5.5 lbs)
Further designs Order code
Communications
Please add “-Z" to Order No. and specify Order
• RS-232 Siemens Dolphin protocol, MOD- code(s).
BUS RTU and ASCII
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
• Option SmartLinx compatible, RS-485 Measuring-point number/identification (max. 16
characters) specify in plain text
Power supply 100 to 230 V AC ± 15%, 50/60 Hz,
36 VA (17 W) or 12 to 30 V DC, Instruction manual Order No.
20 W English C) 7ML1998-5GL01
Ultrasonic transducer Compatible transducers: ST-H German C) 7ML1998-5GL31
and Echomax® series Note: The instruction manual should be ordered as
XPS-10/10F, XPS 15/15F, XCT-8, a separate line on the order
XCT-12 and XRS-5 This device is shipped with the Siemens Milltronics
mA output signal 2-core copper conductor, twisted, manual CD containing the complete ATEX Quick
shielded, 0.5 to 0.75 mm² (22 to Start and instruction manual library.
18 AWG), Belden® 8760 or equiv- Other Instruction manual
alent is acceptable
Smartlinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
Displays and controls Smartlinx PROFIBUS DP, English C) 7ML1998-1AQ03
• Rack and panel mount 75 x 20 mm (3 x 0.8") LCD (select- Smartlinx PROFIBUS DP, German C) 7ML1998-1AQ33
able backlighting) Smartlinx PROFIBUS DP, French C) 7ML1998-1AQ12
• Wall mount 100 x 40 mm (4 x 1.5") multfield Smartlinx Devicenet, English C) 7ML1998-1BH02
LCD, backlit Note: The appropriate Smartlinx instruction manual
should be ordered as a separate line on the order
Programming Using removable handheld pro-
grammer (ordered separately) or
Dolphin Plus software (option) L) Subject to export regulations AL: N, ECCN: 3A991X

Memory 1 Mbyte RAM (static) with


battery, 1 Mbyte flash EPROM
Certificates and approvals CE, FM, CSA
1)
The measuring range corresponds to the distance from the zero point to the
sensor face, plus any range extension (P801)

March 2009 Siemens FI 01 · 2009 US Edition 5/129


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LUC500

Selection and Ordering data Order No. ■ Dimensional drawings


SITRANS LUC500 L) 7 M L 5 0 0 1 -
A complete ultrasonic level controller for monitoring
and control of water distribution and wastewater 7 7 7 77 - 77 A 7
collection systems, with energy-saving algorithms.
Optional Equipment
Handheld programmer 7ML1830-2AG
ERS500 Configuration Tool software, CD, cable kit, B) 7ML1930-1AE
and License
ERS500 Configuration Tool software, License only B) 7ML1930-1AF
ERS500 Configuration Tool software, B) 7ML1930-1AG
demo CD only
See SmartLinx product page 5/289 for more infor-
mation.
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), 7ML1930-1AC
one text line, suitable for enclosures
SITRANS RD100 Remote display - see RD100 on
page 5/292
SITRANS RD200 Remote display - see RD200 on
page 5/294
Auxiliary Cards. Access code required 1)
1 MB static RAM extended memory C) PBD-51034040
2 analog input / 2 analog output for rack and C) PBD-51034039
panel mount version
5 2 analog input / 2 analog output for wall mount
version
C) PBD-51034044

C)
8 digital input for rack and panel mount version PBD-51034042
8 digital input for wall mount version C) PBD-51034043
4 analog input for rack and panel mount version C) PBD-51034045
C)
4 analog input for wall mount version PBD-51034046
4 analog output for rack and panel mount version C) PBD-51034047
4 analog output for wall mount version C) PBD-51034048
8 digital inputs, 2 analog inputs, 2 analog outputs, C) PBD-51034272
wall mount
Access code, dual point capability C) 7ML1830-1KA

Auxiliary Cards2)
1 MB static RAM extended memory C) 7ML1830-1KR
2 analog input / 2 analog output for rack and C) 7ML1830-1KS
panel mount version
2 analog input / 2 analog output for wall mount C) 7ML1830-1KT
version
8 digital input for rack and panel mount version C) 7ML1830-1KU
8 digital input for wall mount version C) 7ML1830-1LA
4 analog input for rack and panel mount version C) 7ML1830-1LB
4 analog input for wall mount version C) 7ML1830-1LC
4 analog output for rack and panel mount version C) 7ML1830-1LD
4 analog output for wall mount version C) 7ML1830-1LE
8 digital inputs, 2 analog inputs, 2 analog outputs, C) 7ML1830-1LF
wall mount
1)
Values of parameters P345 and P346 must be obtained from the customer
in order to generate the order for the access code.
2)
For replacement of auxiliary card or spare auxiliary card. Access code not
required. Must be used only as replacement cards.
B) Subject to export regulations AL: N, ECCN: EAR99S SITRANS LUC500 dimensions
C) Subject to export regulations AL: N, ECCN: EAR99

5/130 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LUC500

■ Schematics

Rack and Panel Mount

Notes
See Note 2 1. Transducer uses 2 wire twisted pair
AC Version with shield only.
2. Terminals 49-64 are for use with
optional expansion I/O cards.

DC Version

See Note 1 5

Wall Mount

Optional mA Input card shown. Other


expansion cards I/O available - see
SITRANS LUC 500 options list.

27 43 -

!
1
28 44 +
AC Version 29 45 -
2 !
SL1 1 14 30 46 +
10 7
SL2 2 15 31 47
11 SL3 3 16 32 48 -
8
L2/N 12 SL4 4 17 33 49 +
SMARTLINX
SL5 5 18 DCD 34 50
L1 13
SL6 6 19 RXD 35 51 +
TS-3
SL7 7 20 TXD 36 52 -
SL8 8 21 DTR 37 53
10 RS232
SL9 9 22 SG 38 54
1
11 SYNC 10 23 DSR 39 55
6 2
11 24 RTS 40 56
12 5 3
12 25 CTS 41 57
4
13 13 26 24V 24V 42 58

TB3 TB4 TB1 TB2


DC Version

SITRANS LUC500 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/131


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02

■ Overview ■ Overview

The SITRANS LU01 is an ultrasonic long-range level controller The SITRANS LU02 is a dual point ultrasonic long-range level
for liquids and solids in a single vessel up to 60 m (200 ft). controller for liquids and solids in one or two vessels up to 60 m
(200 ft).
Handheld programmer shown is an accessory and must be ordered sep-
5 arately. Handheld programmer shown is an accessory and must be ordered sep-
arately.
■ Benefits
• Single point, long-range level monitoring ■ Benefits
• Easy to install and easy to program using removable infrared • Dual point, long-range level monitoring
keypad (optional) • Easy to install; easy to program using removable infrared key-
• Compatible with all Echomax® transducers pad (optional)
• Backlit LCD display with reading in standard engineering units • Compatible with all Echomax® transducers
• Automatic level-to-volume conversion for standard or custom • Backlit LCD display with reading in standard engineering units
tank shapes • Automatic level-to-volume conversion for standard or custom
• Dolphin Plus and SmartLinx compatible tank shapes
• High/low alarms • Dolphin Plus and SmartLinx compatible
• High/low alarms
■ Application
The system consists of a SITRANS LU01 monitor linked to a non-
■ Application
contacting ultrasonic transducer that can be mounted up to SITRANS LU02 will measure liquids, solids or a combination of
365 m (1200 ft) away. The SITRANS LU01 will measure distance, both in one or two vessels of different sizes, shapes and config-
level or volume, and it features patented Sonic Intelligence® urations up to 60 m (200 ft).
echo processing software for superior reliability.
The system uses ultrasonic technology to measure level, space,
Readings are displayed in user-selectable linear engineering distance, volume or average/differential. It features patented
units on the backlit LCD. Sonic Intelligence® echo processing software for superior reli-
ability. Transducers can be mounted up to 365 m (1200 ft) from
An on-board communications port automatically configures for the monitor.
RS-232, RS-485 or bi-polar current loop. The SITRANS LU01 will
connect to a DCS or PLC using Siemens SmartLinx® interface Readings are displayed in user-selectable linear engineering
modules, giving you remote 2-way communication and full pa- units on the backlit LCD.
rameter access. Modules for popular industrial buses can be
factory installed or added later to meet changing needs. No ex- It features an onboard communications port that automatically
ternal gateway is required, reducing hardware and cabling configures for RS-232, RS-485 or bi-polar current loop. It will
costs. connect to a DCS or PLC using Siemens SmartLinx® interface
modules, giving you remote 2-way communication and full pa-
• Key Applications: chemical storage, liquid storage, bulk sol- rameter access. Modules for popular industrial buses can be
ids storage (gravel, flour bins, grains, cereals), plastic pellets factory installed or added later to meet changing needs. No ex-
ternal gateway is required, reducing hardware and cabling
costs.
• Key Applications: chemical storage, liquid storage, bulk sol-
ids storage (gravel, flour bins, grains, cereals), plastic pellets,
tripper car

5/132 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02

■ Technical specifications Certificates and approvals CE, CSANRTL/C, FM, ATEX II 3D


Options
Mode of operation
• External temperature sensor TS-3
• Measuring principle Ultrasonic level measurement
• Communications • SmartLinx: protocol-specific
• Measuring range 0.3 to 60 m (1 to 200 ft) modules as interface for popular
• Measuring points industrial fieldbus systems
- SITRANS LU01 Max. one point • Dolphin Plus: Siemens
Windows®-compatible interface
- SITRANS LU02 Max. two points and ComVerter link (infrared)
Output
• Ultrasonic transducer Echomax series, ST-H transduc-
ers
• Relays 4 SPDT Form C relays, rated at 5
A at 250 V AC, resistive load
• mA output 0/4 to 20 mA, optically isolated
- Max. load 750 Ω, isolated, 30 V
- Resolution 0.1 % of range
- Output LU01 Max. one mA output
- Outputs LU02 Max. two mA outputs
Accuracy
• Error in measurement 0.25% of range or 6 mm (0.24"),
whichever is greater 5
• Resolution 0.1% of measuring range or 2 mm
(0.08"), whichever is greater
• Temperature compensation -50 to +150 ºC (-58 to +302 ºF)
• Integral temperature sensor
• External TS-3 temperature sen-
sor (optional)
• Programmable fixed tempera-
ture
Rated operating conditions
Ambient conditions
Ambient temperature for enclosure -20 to +50 ºC (-4 to +122 ºF)
Design
Weight 2.7 kg (6 lbs)
Material (enclosure) Polycarbonate
Degree of protection (wall mount) IP65
Electrical connection
• Ultrasonic transducer cable exten- RG62-A/U coaxial cable with low
sion capacitance
• mA output signal 2-core copper conductor, twisted,
shielded, 0.5 to 0.75 mm² (22 to
18 AWG), Belden® 8760 or equiv-
alent is acceptable
• Electrical connection and relay Copper conductor according to
connection local requirements, rated 250 V
5A
• Synchronization Up to 16 LU01/LU02 units can be
synchronized together
Power supply
AC model 100/115/200/230 V AC ± 15%,
50/60 Hz, 31 VA
DC model 18 to 30 V DC, 25 W
Displays and controls 51 x 127 mm (2 x 5") graphics
LCD with backlighting
• Memory EEPROM (non-volatile), no
backup battery required
• Programming Using removable programmer
(ordered separately) or Dolphin
Plus (option)

March 2009 Siemens FI 01 · 2009 US Edition 5/133


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LU01/LU02 C) 7 M L 5 0 0 4 - SITRANS LU01/LU02 C) 7 M L 5 0 0 4 -
Single or dual point ultrasonic long-range level 7 7 7 77 - 77 Single or dual point ultrasonic long-range level 7 7 7 77 - 77
monitoring system for liquids and solids, and monitoring system for liquids and solids, and
ranges up to 60 m (200 ft). ranges up to 60 m (200 ft).
Number of measuring points Instruction manual
LU01 version, 1 point 1 SITRANS LU02, English C) 7ML1998-5BD02
LU02 version, 2 points 2 SITRANS LU02, French C) 7ML1998-5BD12

Input voltage SITRANS LU02, German C) 7ML1998-5BD32

100/115/200/230 V AC, voltage selector switch A SITRANS LU01, English C) 7ML1998-5BE02


18 to 30 V DC B SITRANS LU01, French C) 7ML1998-5BE12

Feature software SITRANS LU01, German C) 7ML1998-5BE32


Note: The instruction manual should be ordered as
Standard A a separate line item.
Application software This device is shipped with the Siemens Milltronics
Standard 1 manual CD containing the complete ATEX Quick
Data communications Start and instruction manual library.
No module (SmartLinx ready) 0 Other Instruction manuals
SmartLinx Allen-Bradley® Remote 1 SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
I/O module SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP module 2 SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33
®
SmartLinx Modbus RTU module 3 SmartLinx PROFIBUS DP, French C) 7ML1998-1AQ12
SmartLinx Modbus, English C) 7ML1998-1BF01

5
Enclosure
Wall mount 1 SmartLinx Modbus, German C) 7ML1998-1BF31
Wall mount, drilled, 6 x M20x1.5 3 Note: The appropriate SmartLinx instruction manual
Approvals should be ordered as a seperate line on the order.
CE, CSANRTL/C, FM1) A Accessories
CE2) B Handheld programmer 7ML1830-2AN
ATEX II 3D1) C Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), 7ML1930-1AC
one text line, suitable for enclosures
Further designs Order code
M20 cable gland kit (6 M20 cable glands, 7ML1830-1GM
Please add “-Z" to Order No. and specify Order 6 M20 nuts, 3 stop plugs)
code(s). TS-3 Temperature Sensor - see TS-3 on
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15 page 5/167
Measuring-point number/identification (max. 16 Spare parts
characters) specify in plain text
Card, LU01 mother main, comm ready C) 7ML1830-1KX
Card, LU02 mother main, comm ready C) 7ML1830-1MA
Card, LU02 daughter, comm ready C) 7ML1830-1LP

Card, LU01 daughter, comm ready C) 7ML1830-1LN


Card, display 7ML1830-1LQ
See SmartLinx product page 5/289 for more infor-
mation.
1)
Available with enclosure option 1 only
2) Available with enclosure option 3 only
C) Subject to export regulations AL: N, ECCN: EAR99
®
Modbus is a registered trademark of Schneider Electric.
®
Allen-Bradley is a registered trademark of Rockwell Automation.
TMDeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA).

5/134 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02

■ Dimensional drawings

285 mm 106 mm 285 mm 106 mm


(11.2”) (4.2”) (11.2”) (4.2”)
267 mm 92 mm 267 mm 92 mm
(10.5”) (3.6”) (10.5”) (3.6”)

100 100
% %

209 mm 1 2 3 4
209 mm 1 2 3 4

(8.2”)
0 0

(8.2”)
11 22 33 44 11 22 33 44

55 66 77 88 55 66 77 88
mA
mA mA
mA

172 mm 99 00
PP PPX X X
172 mm 99 00
PP PPX X X

(6.8”) C
C %%
(6.8”) C
C %%

SITRANS LU 01 SITRANS LU 02

Mounting hole 4.3 mm Mounting hole 4.3 mm


Suitable location for conduit entrances. (0.17”) diameter Suitable location for conduit entrances. (0.17”) diameter
Use water tight conduit hubs to maintain access under lid Use water tight conduit hubs to maintain access under lid
enclosure rating. (4 places) enclosure rating. (4 places)

Dimensional drawings for SITRANS LU01 (left) and SITRANS LU02 (right)
5

March 2009 Siemens FI 01 · 2009 US Edition 5/135


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU01 and LU02

■ Schematics

5
SITRANS LU01 connections

SITRANS LU02 connections

5/136 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU10

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Ultrasonic level measurement
Measuring range Max. 0.3 to 60 m (1 to 200 ft)
Measuring points Max. 10
Output
• Ultrasonic transducer Echomax® series, ST-H transduc-
ers
• Relays • SITRANS LU SAM module (op-
tion): 20 alarm/control relays
• SPDT Form C relays, rated 5 A at
250 V AC, resistive load
• mA output SITRANS LU A0 module (option):
0/4 to 20 mA, optically isolated
- Max. load 750 Ω, isolated
- Resolution 0.1 % of range
Accuracy
SITRANS LU10 is an ultrasonic long-range level monitor for liq-
uids and solids, offering 10-point monitoring in a single unit. • Error in measurement 0.25 % of range or 6 mm (0.24"),
whichever is greater
Handheld programmer shown is an accessory and must be ordered sep-
• Resolution 0.1% of measuring range or 2 mm
arately.
(0.08"), whichever is greater 5
■ Benefits • Temperature compensation -50 to +150 °C (-58 to +302 °F)

• Ten point, long-range level monitoring • Integral temperature sensor


• Automatic level-to-volume conversion for standard or custom • External TS-3 temperature sen-
tank shapes sor (expandable to 10 inputs
with optional TIB-9 card)
• Dolphin Plus and SmartLinx® compatible
• Programmable fixed tempera-
• Backlit LCD display with reading in standard engineering units ture
• Easy to install, easy to program using removable infrared key- Rated operating conditions
pad (optional)
Ambient conditions
■ Application • Ambient temperature for enclosure -20 to +50 °C (-4 to +122 °F)
Design
It can be used in a wide range of applications to scan liquids,
solids or a combination of both contained in vessels of differing • Weight 2.7 kg (6 lbs)
size, shape and configuration up to 60 m (200 ft). • Material (enclosure) Polycarbonate
SITRANS LU10 uses ultrasonic technology to measure level, • Degree of protection (wall mount) IP65/Type 4X/NEMA 4X
space, distance, volume or average/differential. Transducers
Electrical connection
can be mounted up to 365 m (1200 ft) from the monitor. The
SITRANS LU10 features patented Sonic Intelligence® echo pro- • Ultrasonic transducer RG62-A/U coaxial cable with low
cessing software for superior reliability. Readings are displayed capacitance
in user-selectable linear engineering units on the LCD. • Signal transmission 2-core copper conductor, twisted,
shielded, 0.5 to 0.75 mm² (22 to
SITRANS LU10 will connect to a DCS or PLC using Siemens 18 AWG), Belden® 8760 or equiv-
SmartLinx® interface modules, giving you remote 2-way commu- alent is acceptable
nication and full parameter access. Modules for popular indus-
trial buses can be factory installed or added later to meet chang- • Electrical connection and relay Copper conductor according to
ing needs. No external gateway is required, reducing hardware connection local requirements, rated 250 V
5A
and cabling costs.
• Key Applications: chemical storage, liquid storage, bulk sol- • Synchronization Up to 16 LU10 units can be syn-
chronized together
ids storage (sugar, flour bins, grains, cereals), plastic pellets,
tank farms Power supply 100/115/200/230 V AC ± 15%,
50/60 Hz, 15 VA
Displays and controls 51 x 127 mm (2 x 5") graphics
LCD with backlighting
• Memory EEPROM (non-volatile), no
backup battery required
• Programming Using removable programmer
(ordered separately) or Dolphin
Plus (option)
Certificates and approvals • CE, FM, CSANRTL/C , ATEX II 3D
• Lloyds Register of Shipping
(Categories ENV1, ENV2, ENV3
and ENV5)

March 2009 Siemens FI 01 · 2009 US Edition 5/137


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU10
Options Selection and Ordering data Order No.
• Expansion card TIB-9, increases the number of SITRANS LU10 C) 7 M L 5 0 0 7 -
TS-3 inputs from 1 to 10 Ten point ultrasonic long-range level monitoring 7 7 7 7 7 - 77
• External temperature sensor TS-3 system for liquids and solids applications, and
ranges up to 60 m (200 ft).
• Communications • SmartLinx: protocol-specific
Input voltage
modules as interface for popular
industrial fieldbus systems 100/115, 200/230 V AC, selectable 1
• Dolphin Plus: Siemens Win- Feature software
dows®-compatible interface Standard A
and Application software
ComVerter link (infrared) Standard A
• I/O devices • Max. 3 I/O devices per Data communications
• SITRANS LU10 No module (SmartLinx ready) 0
SmartLInx Allen-Bradley® Remote I/O module 1
• SITRANS LU AO analog output SmartLinx PROFIBUS DP module 2
module (max. 1)
SmartLinx Modbus® RTU module 3
• SITRANS LU SAM, satellite
alarm module (max. 2) TIB-9 temperature card
®
None 0
Windows is a registered trademark of Microsoft Corporation. With TIB-9 card 1
Enclosure
Wall mount 1
Wall mount, drilled (12 x M20x1.5 for cable glands) 2
Approvals

5 CE, CSANRTL/C, FM
ATEX II 3D1)
A
B
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
English C) 7ML1998-5AN02
French C) 7ML1998-5AN12
German C) 7ML1998-5AN32
Note: The instruction manual should be ordered as
a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Other Instruction manuals
SmartLinx Allen-Bradley Remote I/O, English C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German C) 7ML1998-1AQ33
SmartLinx PROFIBUS DP, French C) 7ML1998-1AQ12
SmartLinx Modbus, English C) 7ML1998-1BF01
SmartLinx Modbus, German C) 7ML1998-1BF31
Note: The appropriate SmartLinx instruction manual
should be ordered as a seperate line on the order.
Accessories
Handheld programmer 7ML1830-2AN
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), 7ML1930-1AC
one text line, suitable for enclosures
Temperature Card (TIB-9) C) 7ML1830-1CN
M20 cable gland kit (6 M20 cable glands, 6 M20 7ML1830-1GM
nuts, 3 stop plugs)
TS-3 Temperature Sensor - see TS-3 on page 5/167
Spare parts
Card, mother main, comm ready C) 7ML1830-1ML
Card, daughter, comm ready C) 7ML1830-1LY
Card, display 7ML1830-1LQ
See SmartLinx product page 5/289 for more infor-
mation.
1)
Available with enclosure option 1 only
C) Subject to export regulations AL: N, ECCN: EAR99
®
Modbus is a registered trademark of Schneider Electric.
®Allen-Bradley is a registered trademark of Rockwell Automation.
TM
DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA).

5/138 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU10

■ Dimensional drawings
106 mm
285 mm (4.2”)
267 mm (11.2") 92 mm
(10.5") (3.6”)

100
%

209 mm 1 2 3 4 5 6 7 8 9 10
0

(8.2") 11
0 0 0
2 3 4

172 mm 55
mA
mA
66 7 8

(6.8") 99 00
P PX X X

C %

SITRANS LU 10

Suitable location for conduit entrances. Use Mounting hole


water-tight conduit hubs to maintain enclosure rating. 4.3 mm (0.17") diameter
access under lid
(4 places)

SITRANS LU10 dimensions

■ Schematics
5

SITRANS LU10 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/139


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU SAM

■ Overview ■ Technical specifications


Mode of operation Satellite alarm module
Input
Communications Data from SITRANS LU10
• Transmission rate 4800 bits/s
• Voltage ± 20 mA bipolar current loop
Output
• Relays 20 multi-purpose relays, program-
mable from SITRANS LU10
SPDT Form C relays, rated 5 A at
250 V AC, resistive load
• ± 20 mA bipolar current loop Input and transmission
- Max. load 1 receiving unit
Rated operation conditions
Ambient conditions
• Ambient temperature -20 to +50 °C (-5 to +122 °F)
SITRANS LU SAM Satellite Alarm Module provides up to 20 relay • Location Indoor/outdoor
outputs for the measurement points of the SITRANS LU10 level
monitor. • Installation category II

5
• Pollution degree 4
■ Benefits Design
• The SITRANS LU SAM can be located up to 1500 m (5000 ft) • Weight 3 kg (6.6 lbs)
from the SITRANS LU10 • Material (enclosure) Polycarbonate
• Relay outputs can be assigned to any point on the SITRANS
• Degree of protection Type 4X/NEMA 4X/IP65
LU10
• Cable connection 2 copper conductors, twisted,
■ Application with foil shield/drain wire, 300 V
0.5 to 0.75 mm² (22 to 18 AWG)
The operation of the SITRANS LU SAM is programmed via the SI- • Electrical connection and relay Copper conductor according to
TRANS LU10. The only on-board settings are for bank selection connection local requirements, rated 250 V
and output testing. 5A

Using a SITRANS LU SAM, you can have two relay outputs for all Power supply 100/115/200/230 V AC ± 15%,
50/60 Hz, 20 VA
ten measurement points, all 20 for a single measurement point
or any combination between the two. Displays and controls 1 LED for display of voltage/com-
munications state, 20 LEDs for
All relays are Form C to allow NO or NC wiring. display of relay states
Certificates and approvals CE, FM, CSANRTL/C, C-TICK

Selection and Ordering data Order No.


SITRANS LU SAM C) 7ML5811-1A
Satellite alarm module provides up to 20 relay
outputs for the measurement points of the
SITRANS LU10 level monitor.
Approvals: CSANRTL/C, FM, CE, C-TICK
Instruction manual
English C) 7ML1998-5CF02
German C) 7ML1998-5CF32
Note: Instruction manuals should be ordered as a
separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.

C) Subject to export regulations AL: N, ECCN: EAR99

5/140 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU SAM

■ Dimensional drawings ■ Schematics


16 mm 209 mm
(0.6”) (8.2”)
172 mm lid screws 91 mm
(6.8”) (6 places) (3.6”)
1 11
2 12
3 13
4 14
5 15
6 16
7 17
8 18
9 19
10 20

285 mm
(11.2”)

267 mm
SITRANS LU SAM (10.5”)

suitable location for lid


mounting holes conduit entrances enclosure
(accessed under lid)
4.3 mm (0.17”) diameter mounting screw (by customer)
4 places

SITRANS LU SAM dimensions 5

SITRANS LU SAM connections

March 2009 Siemens FI 01 · 2009 US Edition 5/141


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU AO

■ Overview ■ Technical specifications


Mode of operation Output module
Input
Communications Data from SITRANS LU10
• Transmission rate 4800 bits/s
• Voltage ± 20 mA bipolar current loop
• Polarization Non-polarized
• Max. load 1 receiving unit
Output
• Analog outputs 10 analog outputs, programmable
from SITRANS LU10
0 or 4 to 20 mA, isolated
• ± 20 mA bipolar current loop Input and transmission
- Max. load 750 Ω
- Resolution 0.1%
Rated operating conditions
The SITRANS LU AO Analog Output Module provides remote an-
alog output for the measurement points of the SITRANS LU10 Ambient conditions
level monitor. • Ambient temperature for enclosure -20 to +50 °C (-5 to +122 °F)

5 ■ Benefits
• Location
• Installation category
Indoor/outdoor
II
• Analog outputs can be up to 1500 m (5000 ft) from the
• Pollution degree 4
SITRANS LU10
• Analog outputs can be per transducer and/or average of 2 or Design
more Weight 2 kg (4.4 lbs)
Material (enclosure) Polycarbonate
Degree of protection Type 4X/NEMA 4X/IP65
■ Application • Cable connection 2 copper conductors, twisted,
with foil shield/drain wire, 300 V
The operation of the SITRANS LU AO is programmed via the 0.5 to 0.75 mm² (22 to 18 AWG)
SITRANS LU10. The only on-board settings are for bank selec-
tion and output testing. • Electrical connection and relay Copper conductor according to
connection local requirements, rated 250 V
The SITRANS LU AO can provide up to 10 analog outputs (each 5A
sharing a common negative bus which is electrically isolated Power supply 100/115/200/230 V AC ± 15%,
from ground). 50/60 Hz, 15 VA
Displays and controls 1 LED for display of voltage/com-
munications state
Certificates and approvals CE, FM, CSANRTL/C , C-TICK

Selection and Ordering data Order No.


SITRANS LU AO C) 7ML5810-1A
Provides remote analog output for the measure-
ment points of the SITRANS LU10 level monitor.
Approvals: CSANRTL/C, FM, CE, C-TICK
Instruction manual
English C) 7ML1998-5CE01
German C) 7ML1998-5CE31
Note: Instruction manuals should be ordered as a
separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
C) Subject to export regulations AL: N, ECCN: EAR99

5/142 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic controllers
SITRANS LU AO

■ Dimensional drawings
16 mm 209 mm
(0.6”) (8.2”)
172 mm lid screws 91 mm
(6.8”) (6 places) (3.6”)

285 mm
(11.2”)

267 mm
SITRANS LU AO (10.5”)

suitable location for lid


mounting holes conduit entrances enclosure
(accessed under lid)
4.3 mm (0.17”) diameter mounting screw (by customer)
4 places
SITRANS LU AO dimensions 5
■ Schematics

SITRANS LU AO connections

March 2009 Siemens FI 01 · 2009 US Edition 5/143


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Ultrasonic transducers

■ Overview
Ultrasonic Transducers
Ultrasonic measuring systems are the cost-effective choice for
monitoring and control in short- to long-range applications for
liquids, slurries, and solids in a wide range of industries. Trans-
ducers are impervious to dust, moisture, corrosion, vibration,
flooding and extreme temperature. They are easy to install and
virtually maintenance free. Choose from a wide selection of mod-
els designed for short or long range applications on liquids or
solids.

■ Technical specifications
Echomax Transducers
Liquids Liquids and Solids Solids

Standard High Temperature High Temperature


XRS-5 ST-H XPS-10 XPS-15 XPS-30 XPS-40 XCT-8 XCT-12 XLT-30 XLT-60

5 Max. range 8m
(26 ft)
10 m
(33 ft)
10 m
(33 ft)
15 m
(50 ft)
30 m
(100 ft)
40 m
(130 ft)
8m
(26 ft)
12 m
(40 ft)
30 m
(100 ft)
60 m
(200 ft)
Min. range 0.3 m 0.3 m 0.3 m 0.3 m 0.6 m 0.9 m 0.6 m 0.6 m 0.9 m 1.8 m
(1 ft) (1 ft) (1 ft) (1 ft) (2 ft) (3 ft) (2 ft) (2 ft) (3 ft) (6 ft)
Max. tempera- +65 °C +73 °C +95 °C +95 °C +95 °C +95 °C +145 °C +145 °C +150 °C +150 °C
ture (+149 °F) (+164 °F) (+203 °F) (+203 °F) (+203 °F) (+203 °F) (+293 °F) (+293 °F) (+300 °F) (+300 °F)
Min. tempera- -20 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C
ture (-4 °F) (-40 °F) (-40 °F) (-40 °F) (-40 °F) (-40 °F) (-40 °F) (-40 °F) (-40 °F) (-40 °F)
Typical appli- Wet wells Chemical Dusty sol- Deep wet Powders, Powders, Hot acids Hot acids Clinker and Clinker and
cations and open storage ids and wells and pellets and pellets and and slur- and slurries coal bun- coal bun-
channels and liquid slurries solids solids solids ries, food kers kers
tanks
Frequency 44 kHz 44 kHz 44 kHz 44 kHz 30 kHz 22 kHz 44 kHz 44 kHz 22 kHz 13 kHz
Beam angle 10° 12° 12° 6° 6° 6° 12° 6° 5° 5°
(-3dB)

Thread size R 1" 1" and R 1" R 1" R 1.5" R 1.5" R 1" R 1" 1" NPT 1" NPT
[(BSPT), EN 2" NPT [(BSPT), EN [(BSPT), EN [(BSPT), EN [(BSPT), EN [(BSPT), EN [(BSPT), EN
10226] R 2“ 10226] 10226] 10226] 10226] 10226] 10226]
1" NPT [(BSPT), EN 1" NPT 1" NPT Universal Universal 1" NPT 1" NPT
10226], thread thread
2“ [(BSPP), 1.5" NPT 1.5" NPT
EN ISO
228-1]
Enclosure • PVDF • ETFE • PVDF • PVDF • PVDF • PVDF • PVDF • PVDF • Aluminum • Aluminum
Copoly- • Option: • Option: • Option: • Option: • Option: • Option: • Option: • 304 Stain- • 304 Stain-
mer PVDF Foam fac- Foam Foam fac- Foam fac- Flange Flange less steel less steel
• CSM ing facing ing ing with PTFE with PTFE • Polyester • Polyester
• Option: • Flange • Flange • Flange facing facing
• Silicone • Silicone
Flange with PTFE with PTFE with PTFE • Sanitary
with PTFE facing facing facing version
facing
Compatible with:
SITRANS LU • • • • • • • • • •

SITRANS • • • • • •
LUC500
HydroRanger • • • • • •
200
MultiRanger • • • • • •
100/200
OCM III •

5/144 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
ST-H

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Ultrasonic transducer
Input
Measuring range 0.3 to 10 m (1 to 33 ft)
Output
Frequency 44 kHz
Beam angle 12°
Accuracy
Temperature compensation Compensated by integral temper-
ature sensor
Rated operating conditions
Pressure Normal atmospheric pressure
Ambient conditions
• Ambient temperature -20 to +60 °C (-5 to +140 °F)
(ATEX approved model)
-40 to +73 °C (-40 to +163 °F)
ST-H transducers use ultrasonic technology to measure level in (CSA/FM approved model)
chemical storage and liquid tanks.
Design

■ Benefits Weight 1) 1.4 kg (3 lbs) 5


Material (enclosure) Base and lid made of ETFE or
• Can be mounted on a 2" (50.8 mm) standpipe PVDF (epoxy fitted joint)2)
• Immune to corrosive and harsh environments Process connection 2" NPT [(Taper), ANSI/ASME
• Integral temperature sensor B1.20.1], R 2" [(BSPT), EN 10226]
or G 2" [(BSPP), EN ISO 228-1]
■ Application Degree of protection IP68

The narrow design of the ST-H allows the transducer to be Cable connection 2-core shielded/twisted,
0.519 mm² (20 AWG), PVC sheath
mounted on a 2" (50.8 mm) standpipe. When mounted correctly,
it is completely protected from the process and can even be Cable (max. length) 365 m (1200 ft) with RG 62 A/U
used in harsh, corrosive environments. coaxial cable

During operation, the ultrasonic transducer emits acoustic Options


pulses in a narrow beam perpendicular to the transducer face. • Flange adapter 3" Universal (fits DN 65, PN 10
The level transceiver measures the propagation time between and 3" ASME)
pulse emission and reception of the echo to calculate the dis- • Submergence coupling For maintaining high level read-
tance from the transducer to the material. Variations in sound ve- ings while the transducer is sub-
locity due to changes in temperature within the permissible merged
range are automatically compensated by the integral tempera-
Certificates and approvals CE3), CSA Class I, II, III, Div. 1, Gr.
ture sensor. A, B, C, D, E, F, G T3 (ETFE only),
• Key Applications: chemical storage, liquid tanks FM Class I, II, Div. 1, Gr. C, D, E,
F, G T4A, ATEX II 2G EEx m IIC
T5, C-TICK, INMETRO: Br-Ex m II
T5
1) Approximate shipping weight of transducer with standard cable length
2) When measuring chemicals, check compatibility of ETFE or PVDF and
epoxy, or mount joint external to process.
3)
EMC certificate available on request

March 2009 Siemens FI 01 · 2009 US Edition 5/145


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
ST-H

Selection and Ordering data Order No.


Echomax® ST-H ultrasonic transducer C) 7 M L 1 1 0 0 -
Level measurement in chemical storage and liquid 77A 7 0
tanks
The narrow design of the ST-H allows the trans-
ducer to be mounted on a 2" standpipe.
Measuring range: min. 0.3 m (1 ft), max. 10 m
(33 ft)
Process connection
ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1] 0
ETFE, R 2" [(BSPT), EN 10226] 1
ETFE, G 2" [(BSPP), EN ISO 228-1] 2
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME 3
B1.20.1]
PVDF copolymer, R 2" [(BSPT), EN 10226] 4
PVDF copolymer, G 2" [(BSPP), EN ISO 228-1] 5
Cable length
5 m (16.40 ft) A
10 m (32.81 ft) B
30 m (98.43 ft) C
50 m (164.04 ft) D
100 m (328.08 ft) E
5 Approvals
FM Class I, II, Div. 1, C-TICK1) 2
ATEX II 2G, CSA, C-TICK, INMETRO2) 3
ATEX II 2G, C-TICK, INMETRO3) 4
Instruction manual
Quick Start Manual, multi-language C) 7ML1998-5QK82
Applications Guidelines, multi-language C) 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
ST-H universal submergence shield 7ML1830-1CF
Universal box bracket, mounting kit 7ML1830-1BK
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange 7ML1830-1BT
adapter for 2" NPT
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange 7ML1830-1BU
adapter for 2" BSPT
Easy Aimer 2, NPT with ¾" x 1" PVC coupling 7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
1)
Available with Process connection option 0 only
2) Available with Process connection options 0 to 2 only
3)
Available with Process connection options 3 to 5 only
C) Subject to export regulations AL: N, ECCN: EAR99

5/146 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
ST-H

■ Dimensional drawings

ST-H ultrasonic transducer dimensions

■ Schematics 5

ST-H ultrasonic transducer connections

March 2009 Siemens FI 01 · 2009 US Edition 5/147


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XRS-5

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Ultrasonic transducer
Input
Measuring range 0.3 to 8 m (1 to 26 ft), dependent
on application
Output
Frequency 44 kHz
Beam angle 10°
Accuracy
Temperature error Compensated by integral temper-
ature sensor
Rated operating conditions
Vessel pressure Normal atmospheric pressure
Ambient conditions
• Ambient temperature -20 to +65 °C (-4 to +149° F)
Echomax® XRS-5 ultrasonic transducer provides reliable, con- Design
tinuous level monitoring of liquids and slurries in narrow lift sta-
tions/wet wells, flumes, weirs and filter beds using a beam angle Weight (approximate shipping 1.2 kg (2.6 lbs)
of just 10° and a CSM rubber face. weight of sensor with standard
5 cable length)

■ Benefits Material (enclosure) PVDF copolymer enclosure and


CSM face
• Narrow beam angle of only 10°
Process connection 1" NPT [(Taper),
• Chemically resistant PVDF copolymer enclosure and CSM ANSI/ASME B1.20.1] or R 1"
rubber face [(BSPT), EN 10226]
• Measuring range: 8 m (26 ft) for measurement of liquids and Degree of protection IP65/IP68
slurries Cable connection 2-core shielded/twisted, 0.5 mm2
• Fully submersible: IP68 degree of protection (20 AWG), PVC sheath
• Easy installation with 1" NPT or R 1" BSPT connection Cable (max. length) • 365 m (1200 ft) with RG 62 A/U
coaxial cable
• 365 m (1200 ft) with 2-core twist-
ed pair, foil shield, 0.5 mm2 (20
■ Application AWG), PVC sheath, only for
SITRANS LUC500, MultiRanger
The XRS-5 is non-contacting with a measuring range from 0.3 to 100/200
8 m (1 to 26 ft). Advanced echo processing ensures reliable data
Options
even in conditions with obstructions, turbulence and foam.
Flange version Factory flange with PTFE face for
The hermetically sealed CSM rubber face and the PVDF copol- ASME, EN or JIS configuration
ymer enclosure are designed for maximum resistance to meth-
ane, salt water, caustics and harsh chemicals common to waste- Submergence shield For applications with flooding
possible
water installations. With an IP68 degree of protection, this
rugged sensor is fully submersible in the event of flood condi- Certificates and approvals CE (EMC certificate available on
tions. Use a submergence shield if full submergence is possible request), CSA Class I Div. 2, FM
in the application. A submergence shield will maintain a high Class I, ATEX II 2G, SAA Ex s
Class I
level reading output during submerged conditions.
The low-cost XRS-5 transducer is compatible with a full range of
Siemens controllers, from a basic system for high/low alarm or
simple pump control, up to advanced control systems with com-
munications, telemetry and SCADA integration capabilities.
• Key Applications: wet wells, flumes, weirs, filter beds

5/148 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XRS-5

Selection and Ordering data Order No.


Echomax® XRS-5 transducer C) 7 M L 1 1 0 6 -
With a beam angle of 10°, the XRS-5 provides reli- 7777 0 - 0 7
able, continuous level monitoring of liquids and
slurries in narrow lift stations/wet wells, flumes,
weirs and filter beds.
Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft)
Process connection
1" NPT [(Taper), ANSI/ASME B1.20.1] 1
R 1" [(BSPT), EN 10226] 2
Cable length
5 m (16.40 ft) A
10 m (32.81 ft) B
30 m (98.43 ft) C
Facing
Standard (CSM rubber) A
PTFE (flange versions) B
Approvals
CE, FM Class I, ATEX II 2G, CSA Class I Div. 2, SAA 2
Class I
General Purpose, CE 3
Mounting flange (flush mount)
None A
3" ASME, 150 lbs, flat faced B
4" ASME, 150 lbs, flat faced
6" ASME, 150 lbs, flat faced
C
D
5
DN 80, PN 10/16, Type A, flat faced J
DN 100, PN 10/16, Type A, flat faced K
DN 150, PN 10/16, Type A, flat faced L
JIS10K 3B style Q
JIS10K 4B style R
JIS10K 6B style S
Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5
or EN 1092-1, or JIS B 2238 standard.
Instruction manual
Quick Start Manual, multi-language C) 7ML1998-5QT81
C) 7ML1998-5HV61
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
(0.47 x 1.77"), one text line for fastening on sensors
Submergence shield kit 7ML1830-1BH
Easy Aimer 2, NPT with ¾" x 1" PVC coupling 7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
FMS-200 universal box bracket, mounting kit 7ML1830-1BK
FMS-210 channel bracket, wall mount 7ML1830-1BL
FMS-220 extended channel bracket, wall mount 7ML1830-1BM
FMS-310 channel bracket, floor mount 7ML1830-1BN
FMS-320 extended channel bracket, floor mount 7ML1830-1BP
FMS-350 bridge channel bracket, floor mount 7ML1830-1BQ
(see Mounting Brackets on page 5/166 for more
information)
1" NPT locknut, plastic 7ML1830-1DS
1" BSPT locknut, plastic 7ML1830-1DR
C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/149


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XRS-5

■ Dimensional drawings ■ Schematics


Standard Flange (optional)
25 mm (0.98”)

127 mm 127 mm
(5.0”) (5.0”)

89 mm ANSI, DIN, or JIS


(3.5”)
Submergence Shield
(optional)

155 mm

5 (6.1”)

124 mm
(4.9”)

Mounting: Bracket
Suspended Conduit
flexible
conduit
rigid metal
conduit
steel channel XRS-5 ultrasonic transducer connections

non-metallic
coupling
non-metallic
coupling

transducer

Flexible conduit transducer should not be


subjected to wind, vibration or jarring.

Plywood Submersible

rigid metal
non-metallic conduit
coupling
non-metallic
coupling

submergence
shield
Plywood mounting provides excellent
isolation (must be rigid).
Transducer with submergence shield, used in
applications where flooding is possible.

XRS-5 ultrasonic transducer dimensions

5/150 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

■ Overview

Echomax® XPS/XCT transducers use ultrasonic technology to


measure level in a wide range of liquids and solids.

■ Benefits 5
• Integral temperature compensation
• Low ringing effect reduces blanking distance
• Optional foam facing for dusty applications
• Self-cleaning and low-maintenance
• Chemically resistant
• Hermetically sealed

■ Application
The transducers can be fully immersed, are resistant to steam
and corrosive chemicals and can be installed without flanges.
The XPS series offers versions for various measuring ranges up
to 40 m (130 ft) and up to a max. temperature of +95 °C
(+203 °F).
The XCT series can be used in applications at higher tempera-
tures to measure level up to a distance of 12 m (40 ft) and at a
max. temperature of +145 °C (+293 °F).
During operation, the Echomax transducers emit acoustic
pulses in a narrow beam. The level monitor measures the prop-
agation time between pulse emission and its reflection (echo) to
calculate the distance.

March 2009 Siemens FI 01 · 2009 US Edition 5/151


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

■ Technical specifications
Input XPS-10 (standard XPS-15 (standard XPS-30 XPS-40 XCT-8 (standard XCT-12
and F models) and F models) and sanitary mod-
els)
Measuring range 0.3 to 10 m Standard: 0.6 to 30 m 0.9 to 40 m 0.6 to 8 m 0.6 to 12 m
(1 to 33 ft) 0.3 to 15 m (2 to 100 ft) (3 to 130 ft) (2 to 26 ft) (2 to 40 ft)
(1 to 50 ft)
Flanged:
0.45 to 15 m
(1.5 to 50 ft)

Output
Frequency 44 kHz 44 kHz 30 kHz 22 kHz 44 kHz 44 kHz
Beam angle 12° 6° 6° 6° 12° 6°
Environmental
Location Indoors/outdoors
Ambient tempera- -40 to +95 °C (-40 to +203 °F) Standard: -40 to +145 °C
ture -40 to +145 °C (-40 to +293 °F)
(-40 to +293 °F)
Sanitary:

5 -40 to +125 °C
(-40 to +260 °F)
Pollution degree 4
Pressure 8 bar g (120 psi g) 8 bar g (120 psi g) 0.5 bar g 0.5 bar g Standard: 4 bar g (60 psi g):
Flanged: Flanged: 0.5 bar g (7.25 psi g) (7.25 psi g) -40 to +138 °C (-40 to +280 °F)
0.5 bar g (7.25 psi g) Flanged: 0.5 bar g Standard: 8 bar g (120 psi g):
(7.25 psi g) (7.25 psi g) -40 to +95 °C (-40 to +203 °F)
Flanged: 0.5 bar g (7.25 psi g)
Sanitary: XCT-8: 0.5 bar g (7.25 psi g)
Design
Weight 0.8 kg 1.3 kg (2.8 lbs) 4.3 kg 8 kg 0.8 kg 1.3 kg
(1.8 lbs) Flanged: 2 kg (9.5 lbs) (18 lbs) (1.7 lbs) (2.8 lbs)
(4.4 lbs)
Power supply Operation of transducer only with approved Siemens Milltronics controllers
Material Standard: PVDF Standard: PVDF Standard: PVDF PVDF Standard: PVDF
Flanged: PVDF with Flanged: PVDF with Flanged: PVDF with Options: DERAKANE® flange; PTFE face
CPVC flange CPVC flange CPVC flange with universal PVDF flange
Option: PTFE face Option: PTFE face Option: PTFE face
with CPVC flange with CPVC flange with CPVC flange
Color Standard: blue Standard: blue blue blue white
F: gray F: gray
Process Standard: 1" NPT or Standard: 1" NPT or 1.5" universal thread (NPT or BSPT) 1" NPT or R 1" (BSPT), EN 10226
connection 1" BSPT 1" BSPT
F: 1" NPT F: 1" NPT
Degree of IP65/IP67 IP65/IP67 IP65/IP67 IP65/IP67 IP65/IP67 IP65/IP67
protection
Cable 2 wire twisted pair/braided and foil shielded 0.5 mm² (20 AWG) PVC jacket 2 wire twisted pair/braided and foil
shielded 0.5 mm² (20 AWG) silicone
jacket
Separation Max. 365 m (1200 ft)
Certificates and Standard: Standard: CE1), CSA, FM, CE1), CSA, FM, Standard: CE1), CSA, FM,
approvals CE1), CSA, FM, CE1), CSA, FM, ATEX II 2G 1D ATEX II 2G 1D CE1), CSA, FM, ATEX II 2G
ATEX II 2GD ATEX II 2GD ATEX II 2G
F: FM Class I, Div 1, F: FM Class I, Div 1, Sanitary: CSA, 3A
Groups A, B, C and Groups A, B, C and
D, Class II Div 1, D, Class II Div 1,
Groups E, F and G, Groups E, F and G,
Class III Class III
1)
EMC certificate available on request.
® DERAKANE is a registered trademark of Ashland Inc.

5/152 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XPS-10 ultrasonic transducer C) 7 M L 1 1 1 5 - Echomax® XPS-10 ultrasonic transducer C) 7 M L 1 1 1 5 -
High-frequency ultrasonic transducer designed for 7777 0 High-frequency ultrasonic transducer designed for 7777 0
a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Measuring range: min. 0.3 m, max.10 m Measuring range: min. 0.3 m, max.10 m
Mounting thread and facing Instruction Manual
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 Quick Start guide, multi-language C) 7ML1998-5QM82
1" NPT [(Taper), ANSI/ASME B1.20.1] with foam 1 Applications Guidelines, multi-language C) 7ML1998-5HV61
facing1) Note: The Applications Guidelines should be
1" NPT [(Taper), ANSI/ASME B1.20.1] with PTFE 2 ordered as a separate line item on the order.
facing2) This device is shipped with the Siemens Milltronics
R 1" [(BSPT), EN 10226] 3 manual CD containing the complete ATEX Quick
R 1" [(BSPT), EN 10226] with foam facing1) 4 Start and instruction manual library.
R 1" [(BSPT), EN 10226] with PTFE facing2) 5 Accessories
Cable length Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
(0.47 x 1.77"), one text line for fastening on sensors
5 m (16.40 ft) B
Submergence shield kit 7ML1830-1BH
10 m (32.81 ft) C
Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ
30 m (98.43 ft) E
50 m (164.04 ft) F Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
100 m (328.08 ft) K and 1½" BSPT aluminum couplings
Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
5
Mounting flange
None A Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
3" ASME, 150 lb, flat faced C
4" ASME, 150 lb, flat faced D Universal box bracket, mounting kit 7ML1830-1BK
Channel bracket, wall mount 7ML1830-1BL
6" ASME, 150 lb, flat faced E Extended channel bracket, wall mount 7ML1830-1BM
8" ASME, 150 lb, flat faced F
Channel bracket, floor mount 7ML1830-1BN
DN 80, PN 10/16, Type A, flat faced G Extended channel bracket, floor mount 7ML1830-1BP
DN 100, PN 10/16, Type A, flat faced J Bridge channel bracket, floor mount 7ML1830-1BQ
DN 150, PN 10/16, Type A, flat faced L (see Mounting Brackets on page 5/166 for more
JIS10K3B Style M information)
JIS10K4B Style P 1" NPT locknut, plastic 7ML1830-1DS
JIS10K6B Style R 1" BSPT locknut, plastic 7ML1830-1DR
(Note: Flange bolting patterns and facings dimen-
1)
sionally correspond to the applicable ASME B16.5 Not available with flanged versions
2)
or EN 1092-1, or JIS B 2238 standard.) Available with flanged versions only
3)
Valid with mounting thread and facing options 0 to 2 only
Approvals
ATEX II 2 GD, FM Class I Div. 2, SAA Class I 3 C) Subject to export regulations AL: N, ECCN: EAR99
CSA Class I Div. 13) 4
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text

March 2009 Siemens FI 01 · 2009 US Edition 5/153


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

Selection and Ordering data Order No.


Echomax® XPS-10F ultrasonic transducer C) 7 M L 1 1 7 0 -
High-frequency ultrasonic transducer designed for 7777 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.3 m, max.10 m
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1] 1
Cable length
5 m (16.40 ft) B
10 m (32.81 ft) C
30 m (98.43 ft) D
50 m (164.04 ft) E
100 m (328.08 ft) F
Mounting flange, flush mount
None A
3" ASME, 150 lb, flat faced B
4" ASME, 150 lb, flat faced C
6" ASME, 150 lb, flat faced D
8" ASME , 150 lb, flat faced E
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5,
5 or EN 1092-1, or JIS B 2238 standard.)
Approvals
FM Class I Div. 1 1
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
Instruction manual Order No.
English C) 7ML1998-1DU01
Note: The Instruction manual should be ordered as
a separate line item on the order.
Applications Guidelines, multi-language C) 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
(0.47 x 1.77"), one text line for fastening on sensors
Submergence shield kit 7ML1830-1BH
Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ
Easy Aimer 304, with stainless steel coupling 7ML1830-1AU
Universal box bracket, mounting kit 7ML1830-1BK
Channel bracket, wall mount 7ML1830-1BL
Extended channel bracket, wall mount 7ML1830-1BM
Channel bracket, floor mount 7ML1830-1BN
Extended channel bracket, floor mount 7ML1830-1BP
Bridge channel bracket, floor mount 7ML1830-1BQ
(see Mounting Brackets on page 5/166 for more
information)
1" NPT locknut, plastic 7ML1830-1DS
C) Subject to export regulations AL: N, ECCN: EAR99

5/154 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XPS-15 ultrasonic transducer C) 7 M L 1 1 1 8 - Instruction manual
High-frequency ultrasonic transducer designed for 7777 0 Quick Start Manual, multi-language C) 7ML1998-5QM82
a wide variety of liquid and solid applications, for Applications Guidelines, multi-language C) 7ML1998-5HV61
use with approved controllers. Includes integral Note: The Applications Guidelines should be
temperature sensor. ordered as a separate line item on the order.
Measuring range: min. 0.3 m, max. 15 m
This device is shipped with the Siemens Milltronics
Mounting thread and facing manual CD containing the complete ATEX Quick
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 Start and instruction manual library.
1" NPT [(Taper), ANSI/ASME B1.20.1] with foam 1 Accessories
facing1)
Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
1" NPT [(Taper), ANSI/ASME B1.20.1] with PTFE 2 (0.47 x 1.77"), one text line for fastening on sensors
facing2)
Submergence shield kit 7ML1830-1BJ
R 1" [(BSPT), EN 10226] 3
Universal box bracket, mounting kit 7ML1830-1BK
R 1" [(BSPT), EN 10226] with foam facing1) 4
Channel bracket, wall mount 7ML1830-1BL
R 1" [(BSPT), EN 10226] with PTFE facing2) 5
Extended channel bracket, wall mount 7ML1830-1BM
Cable length
Channel bracket, floor mount 7ML1830-1BN
5 m (16.40 ft) B
Extended channel bracket, floor mount 7ML1830-1BP
10 m (32.81 ft) C
30 m (98.43 ft) E Bridge channel bracket, floor mount 7ML1830-1BQ
(see Mounting Brackets on page 5/166 for more
50 m (164.04 ft) F information)
100 m (328.08 ft) K 1" NPT locknut, plastic 7ML1830-1DS
Mounting flange 1" BSPT locknut, plastic 7ML1830-1DR
None A Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
D
E
Easy Aimer 2, aluminum with M20 adapter and 1"
and 1½" BSPT aluminum couplings
7ML1830-1AX
5
DN 150, PN 10/16, Type A, flat faced J Easy Aimer 304 with stainless steel coupling 7ML1830-1AU
DN 200, PN 10/16, Type A, flat faced K Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
JIS10K 6B N
1)
JIS10K 8B P Not available with flanged versions
2)
(Note: Flange bolting patterns and facings dimen- Available with flanged versions only
3)
sionally correspond to the applicable ASME B16.5 Available with mounting options 0 to 2 only
or EN 1092-1, or JIS B 2238 standard.)
C) Subject to export regulations AL: N, ECCN: EAR99
Approvals
ATEX II 2GD, FM Class I Div. 2, SAA Class I 3
CSA Class I Div. 13) 4
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text

March 2009 Siemens FI 01 · 2009 US Edition 5/155


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XPS-15F ultrasonic transducer C) 7 M L 1 1 7 1 - Echomax® XPS-30 ultrasonic transducer C) 7 M L 1 1 2 3 -
High-frequency ultrasonic transducer designed for 7777 0 High-frequency ultrasonic transducer designed for 7777 0
a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Measuring range: min. 0.3 m, max. 15m 1½" universal thread compatible with 1½" NPT and
Mounting thread and facing R 1½" [(BSPT), EN 10226]
1" NPT [(Taper), ANSI/ASME B1.20.1] 1 Measuring range: min. 0.6 m (1.97 ft), max. 30 m
(98.43 ft)
Cable length
Mounting thread and facing
5 m (16.40 ft) B
1½" universal thread 0
10 m (32.81 ft) C
1½" universal thread, foam facing1) 1
30 m (98.43 ft) D
1½" universal thread, PTFE facing2) 2
50 m (164.04 ft) E
Cable length
100 m (328.08 ft) F
5 m (16.40 ft) B
Mounting flange, flush mount 10 m (32.81 ft) C
None A 30 m (98.43 ft) E
6" ASME, 150 lb, flat faced B
50 m (164.04 ft) F
8" ASME, 150 lb, flat faced C
(Note: Flange bolting patterns and facings dimen- 100 m (328.08 ft) K
sionally correspond to the applicable ASME B16.5, Mounting flange
or EN 1092-1, or JIS B 2238 standard.) None A

5
Approvals 6" ASME, 150 lb, flat faced D
FM Class I Div. 1 1 8" ASME, 150 lb, flat faced E
Further designs Order code DN 150, PN 10/16, Type A, flat faced J
Please add “-Z" to Order No. and specify Order DN 200, PN 10/16, Type A, flat faced K
code(s).
JIS10K 6B N
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15 JIS10K 8B P
Measuring-point number/identification (max. 16 (Note: Flange bolting patterns and facings dimen-
characters); specify in plain text sionally correspond to the applicable ASME B16.5
Instruction manual Order No. or EN 1092-1, or JIS B 2238 standard.)
English C) 7ML1998-1DU01 Approvals
Note: The Instruction manual should be ordered as ATEX II 2G 1D, FM Class I Div 2, SAA 5
a separate line item on the order.
Applications Guidelines, multi-language C) 7ML1998-5HV61 Further designs Order code
Note: The Applications Guidelines should be Please add “-Z" to Order No. and specify Order
ordered as a separate line item on the order. code(s).
This device is shipped with the Siemens Milltronics Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
manual CD containing the complete ATEX Quick Measuring-point number/identification (max. 16
Start and instruction manual library. characters) specify in plain text
Accessories Instruction manual Order No.
Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
(0.47 x 1.77"), one text line for fastening on sensors Quick Start Manual, multi-language C) 7ML1998-5QM82

Submergence shield kit 7ML1830-1BJ Applications Guidelines, multi-language C) 7ML1998-5HV61


Note: The Applications Guidelines should be
Universal box bracket, mounting kit 7ML1830-1BK ordered as a separate line item on the order.
Channel bracket, wall mount 7ML1830-1BL
This device is shipped with the Siemens Milltronics
Extended channel bracket, wall mount 7ML1830-1BM manual CD containing the complete ATEX Quick
Channel bracket, floor mount 7ML1830-1BN Start and instruction manual library.
Extended channel bracket, floor mount 7ML1830-1BP Accessories
Bridge channel bracket, floor mount 7ML1830-1BQ Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
(see Mounting Brackets on page 5/166 for more (0.47 x 1.77"), one text line for fastening on sensors
information) 1½" BSPT locknut, plastic 7ML1830-1DP
1" NPT locknut, plastic 7ML1830-1DS Easy Aimer 2, 1½" NPT galvanized coupling 7ML1830-1AN
Easy Aimer 2, with ¾" x 1" NPT PVC coupling 7ML1830-1AQ Easy Aimer 2, 1½" NPT with stainless steel coupling 7ML1830-1AT
Easy Aimer 304 with stainless steel coupling 7ML1830-1AU Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
1)
Not available with flanged versions
2)
Available with flanged versions only
C) Subject to export regulations AL: N, ECCN: EAR99

5/156 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

Selection and Ordering data Order No.


Echomax® XPS-40 ultrasonic transducer C) 7 M L 1 1 2 7 -
High-frequency ultrasonic transducer designed for 7777 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
1½" universal thread compatible with 1½" NPT and
R 1½" [(BSPT), EN 10226]
Measuring range: min. 0.9 m (2.95 ft), max. 40 m
(131.23 ft)
Mounting thread and facing
1½" universal thread 0
1½" universal thread, foam facing 1
Cable length
5 m (16.40 ft) B
10 m (32.81 ft) C
30 m (98.43 ft) E
50 m (164.04 ft) F
100 m (328.08 ft) K
Mounting flange
None A
Approvals
ATEX II 2G 1D, FM Class I Div 2, SAA 5
Further designs
Please add “-Z" to Order No. and specify Order
Order code 5
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
Quick Start Manual, multi-language C) 7ML1998-5QM82
Applications Guidelines, multi-language C) 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
(0.47 x 1.77"), one text line for fastening on sensors
1½" BSPT locknut, plastic 7ML1830-1DP
Easy Aimer 2, 1½" NPT galvanized coupling 7ML1830-1AN
Easy Aimer 2, 1½" NPT with stainless steel coupling 7ML1830-1AT
Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/157


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XCT-8 ultrasonic transducer C) 7 M L 1 1 3 2 - Echomax® XCT-8 ultrasonic transducer C) 7 M L 1 1 3 2 -
High-frequency ultrasonic transducer designed for 7777 0 High-frequency ultrasonic transducer designed for 7777 0
a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Ambient temperatures up to +145 °C (+293 °F) Ambient temperatures up to +145 °C (+293 °F)
Measuring range: min. 0.6 m (2 ft), max. 8 m (26 ft) Measuring range: min. 0.6 m (2 ft), max. 8 m (26 ft)
Mounting thread and facing Instruction manual
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 Quick start manual, multi-language C) 7ML1998-5QM82
1" NPT [(Taper), ANSI/ASME B1.20.1], PTFE fac- 1 XCT-8 with Sanitary Flange, multi-language C) 7ML1998-5HX61
ing1) Note: This manual should be ordered as a separate
R 1" [(BSPT), EN 10226] 2 line item with Mounting Option V.
Applications Guidelines, multi-language C) 7ML1998-5HV61
R 1" [(BSPT), EN 10226], PTFE facing1) 3 Note: The Applications Guidelines should be
Cable length ordered as a separate line item on the order.
1 m (3.28 ft) A This device is shipped with the Siemens Milltronics
5 m (16.40 ft) B manual CD containing the complete ATEX Quick
10 m (32.81 ft) C Start and instruction manual library.
30 m (98.43 ft) E Accessories
50 m (164.04 ft) F Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
100 m (328.08 ft) K (0.47 x 1.77"), one text line for fastening on sensors
Submersible hood 7ML1830-1BH
Mounting flange Universal box bracket, mounting kit 7ML1830-1BK
None
5
A Channel bracket, wall mount 7ML1830-1BL
3" ASME, 150 lb, flat faced C Extended channel bracket, wall mount 7ML1830-1BM
4" ASME, 150 lb, flat faced D Channel bracket, floor mount 7ML1830-1BN
6" ASME, 150 lb, flat faced E Extended channel bracket, floor mount 7ML1830-1BP
DN 80, PN 10/16, Type A, flat faced G Bridge channel bracket, floor mount 7ML1830-1BQ
DN 100, PN 10/16, Type A, flat faced J (see Mounting Brackets on page 5/166 for more
DN 150, PN 10/16, Type A, flat faced L information)
JIS10K 3B M 1" NPT locknut, plastic 7ML1830-1DS
JIS10K 4B P 1" BSPT locknut, plastic 7ML1830-1DR
JIS10K 6B R Easy Aimer 304 with stainless steel coupling 7ML1830-1AU
(Note: Flange bolting patterns and facings dimen- Easy Aimer, aluminum, with M20 adapter and ¾ to 7ML1830-1AX
sionally correspond to the applicable ASME B16.5 1" and 1½" BSPT couplings
or EN 1092-1 or JIS B 2238 standard.) Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
3" universal2) S 1½" BSPT 304 SS couplings
4" universal3) T Sanitary, 4" mounting clamp 7ML1830-1BR
6" universal4) U Sanitary, isolating gasket C) 7ML1830-1KC
4" sanitary flange, available with approval option 6 V 1)
Available with flange versions S to V only
and PTFE facing only 2) Universal fits 3" ASME, DN 80, JIS 10K3B style
3)
Approvals Universal fits 4" ASME, DN 100, JIS 10K4B style
4)
ATEX II 2G, FM Class I, Div. 2, SAA 4 Universal fits 6" ASME, DN 150, JIS 10K6B style
CSA Class I Div. 1, available with mounting thread 5 C) Subject to export regulations AL: N, ECCN: EAR99
and facing option 0
3A Sanitary (only with 4" sanitary flange, option V) 6
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text

5/158 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

Selection and Ordering data Order No. Selection and Ordering data Order No.
Echomax® XCT-12 ultrasonic transducer C) 7 M L 1 1 3 6 - Echomax® XCT-12 ultrasonic transducer C) 7 M L 1 1 3 6 -
High-frequency ultrasonic transducer designed for High-frequency ultrasonic transducer designed for
7777 0 7777 0
a wide variety of liquid and solid applications, for a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral use with approved controllers. Includes integral
temperature sensor. temperature sensor.
Ambient temperatures up to +145 °C (+293 °F) Ambient temperatures up to +145 °C (+293 °F)
Measuring range: min. 0.6 m (2 ft), max.12 m (40 ft) Measuring range: min. 0.6 m (2 ft), max.12 m (40 ft)
Mounting thread and facing Accessories
1" NPT [(Taper), ANSI/ASME B1.20.1] 0 Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
1" NPT [(Taper), ANSI/ASME B1.20.1], PTFE facing, 1 (0.47 x 1.77"), one text line for fastening on sensors
available for flange options U only1) Submergence shield kit 7ML1830-1BJ
R 1" [(BSPT), EN 10226] 2 Universal box bracket, mounting kit 7ML1830-1BK
R 1" [(BSPT), EN 10226], PTFE facing, available for 3 Channel bracket, wall mount 7ML1830-1BL
flange options U only1) Extended channel bracket, wall mount 7ML1830-1BM
Cable length Channel bracket, floor mount 7ML1830-1BN
1 m (3.28 ft) A Extended channel bracket, floor mount 7ML1830-1BP
5 m (16.40 ft) B Bridge channel bracket, floor mount 7ML1830-1BQ
10 m (32.81 ft) C (see Mounting Brackets on page 5/166 for more
information)
30 m (98.43 ft) E
1" NPT locknut, plastic 7ML1830-1DS
50 m (164.04 ft) F
1" BSPT locknut, plastic 7ML1830-1DR
100 m (328.08 ft) K
Easy Aimer 304 with stainless steel coupling 7ML1830-1AU
Mounting flange
Easy Aimer 2, aluminum with M20 adapter and 1"
5
7ML1830-1AX
None A and 1½" BSPT aluminum couplings
6" ASME, 150 lb, flat faced D Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
8" ASME, 150 lb, flat faced E 1½" BSPT 304 SS couplings
DN 150, PN 10/16, Type A, flat faced J 1)
Available with universal flanges only
DN 200, PN 10/16, Type A, flat faced K
C) Subject to export regulations AL: N, ECCN: EAR99
JIS10K 6B N
JIS10K 8B P
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5
or EN 1092-1 or JIS B 2238 standard.)
6" universal for 6" ASME, DN 150 or JIS 10K6B style U
Approvals
ATEX II 2G, FM Class I, Div. 2, SAA 3
CSA Class I, Div. 1, available with mounting thread 4
and facing option 0 only
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
Quick Start Manual, multi-language C) 7ML1998-5QM82
Applications Guidelines, multi-language C) 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.

March 2009 Siemens FI 01 · 2009 US Edition 5/159


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XPS and XCT

■ Dimensional drawings ■ Schematics

XPS and XCT ultrasonic transducer dimensions

Version
Dimension XPS-10 XPS-15 XPS-30 XPS-40
A 88 mm 121 mm 175 mm 206 mm
(3.464") (4.764") (6.890“) (8.110")
B 122 mm 132 mm 198 mm 229 mm
(4.803") (5.197") (7.795") (9.016")
C According to ASME, DN and JIS n/a
E 124 mm 158 mm n/a n/a
(4.882") (6.220")
F 152 mm 198 mm n/a n/a
(5.984") (7.795")
XPS and XCT ultrasonic transducer connections
J 28 mm (1.1") 28 mm (1.1") 28 mm (1.1") 28 mm (1.1")

Version
Dimension XCT-8 XCT-12
A 88 mm(3.464") 121 mm (4.764")
B 122 mm (4.803") 132 mm (5.197")
C According to ASME, DIN and JIS
E n/a n/a
F n/a n/a
G Sanitary version: n/a
119 mm (4.68")
H Sanitary version: n/a
122 mm (4.8")
J 28 mm (1.1") 28 mm (1.1")

5/160 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XLT

■ Overview ■ Technical specifications


Mode of operation
Measuring principle Ultrasonic transducer
Input
Measuring range
• XLT-30 0.9 to 30 m (3.0 to 100 ft)
• XLT-60 1.8 to 60 m (6.0 to 200 ft)
Output
• Frequency
- XLT-30 22 kHz
- XLT-60 13 kHz
• Beam angle1) 5°
Accuracy
Temperature error Compensated by transducers
internal temperature sensor

Echomax® XLT transducers use ultrasonic technology to mea- Rated operating conditions
sure level in a wide range of bulk solids. Ambient conditions
• Ambient temperature
■ Benefits - XLT-30 and XLT-60 -40 to +150 °C (-40 to +300 °F) 5
• Sealed aluminum face Design
• Integral temperature sensor • Weight
• Self-cleaning and low maintenance
- XLT-30 4.3 kg (9.5 lbs)
• Connect using only two wires
- XLT-60 6.6 kg (14.5 lbs)
• Easy to install
• Material (enclosure) Aluminium, 304 stainless steel,
polyester and silicone
■ Application • Degree of protection IP68
XLT transducers operate with Siemens SITRANS LU transceivers • Color
in measuring ranges from 0.9 to 60 m (1.8 to 200 ft) and temper-
atures up to +150 °C (+300 °F). A beam angle of just 5° provides - XLT-30 and XLT-60 Red
accurate readings in deep, narrow tanks. Mounting 1" NPT [(Taper), ANSI/ASME
B1.20.1]
With increased signal sensitivity, the XLT transducers from Sie-
mens can operate in difficult applications such as limestone, ce- • Cable connection 2-core shielded/twisted, 0.5 mm2
ment clinker and hot stone. All models have a sealed aluminum (20 AWG), silicone sheath
face to withstand very harsh environments. • Cable (max. length) 365 m (1200 ft) with RG 62 AU
coaxial cable
During operation, Echomax transducers emit acoustic pulses in
a narrow beam. The level transceiver measures the propagation • Certificates and approvals CE (EMC certificate available on
time between pulse emission and reception of the echo to calcu- request), CSANRTL/C, FM, ATEX II
late the distance from the transducer to the material. Tempera- 2G 1D T5
ture variations are automatically compensated by the integral 1)
Definition of beam width: twice the angle at which the off-axis transmission
temperature sensor. is 3 dB less than the acoustic pressure level of the transmission axis (as
measured equidistant from the sensor face).
• Key Applications: bulk solids including limestone, cement
clinker, hot stone and coal bunkers

March 2009 Siemens FI 01 · 2009 US Edition 5/161


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XLT

Selection and Ordering data Order No. ■ Dimensional drawings


Echomax® XLT-30, XLT-60, ultrasonic transducer
High-frequency ultrasonic transducer designed for
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.9 m, max. 30 m
Process connection:
1" NPT [(Taper), ANSI/ASME B1.20.1]
XLT-30: C) 7 M L 1 1 4 1 -
XLT-60: C) 7 M L 1 1 4 5 -
77 E7 0
Facing
XLT-30 0
XLT-60 1
XLT-30, nylon (standard model) 2
XLT-60, nylon (standard model) 3
Cable length
1 m (3.28 ft) A
5 m (16.40 ft) B
10 m (32.81 ft) C
20 m (65.62 ft) D
5 30 m (98.43 ft)
50 m (164.04 ft)
E
F
70 m (229.66 ft) G
80 m (262.47 ft) H
90 m (295.28 ft) J
100 m (328.08 ft) K
Approvals
ATEX II 2G 1D, CSA Class I Div. 1, FM Class I 3
Div. 2, CE
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Instruction manual Order No.
Quick Start manual, multi-language C) 7ML1998-5QS81
Applications Guidelines, multi-language C) 7ML1998-5HV61
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ XLT ultrasonic transducer dimensions
(0.47 x 1.77"), one text line for fastening on sensors
Easy Aimer 2, 1" NPT galvanized 7ML1830-1AP XLT-30 XLT-60
Easy Aimer 304 with stainless steel coupling 7ML1830-1AU d 249 mm (9.8") 324 mm (12.75")
Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX h 264 mm (10.4") 335 mm (13.2")
and 1½" BSPT aluminum couplings
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
C) Subject to export regulations AL: N, ECCN: EAR99

5/162 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Ultrasonic transducers
Echomax XLT

■ Schematics

XLT ultrasonic transducer connections

March 2009 Siemens FI 01 · 2009 US Edition 5/163


© Siemens AG 2009

Level instruments
Continuous level measurement - Accessories for ultrasonic
EA aiming devices

■ Application ■ Application
EA 304 aiming device EA 2 aiming device
The Easy Aimer 304 flange is a stainless steel aiming device for The Easy Aimer 2 flange is a cast aluminum aiming device for
alignment of Siemens ultrasonic transducers used for level mea- alignment of Siemens ultrasonic transducers.
surement of bulk solids.
The flange has graduated adjustments and an adjustable inser-
The sensor must be mounted aimed towards the low level draw tion length. When used for applications with bulk solids, the sen-
point in the silo. The sensor can be rotated through 360° and an- sor is mounted so that it is aimed towards the lower level draw
gled at 0 to 27° off vertical. It must be mounted using an access point in the silo. The sensor can be rotated through 360° and an-
plate with welded studs or a flange in order to isolate the mount- gled at 0 to 20° off vertical. It must be mounted using an access
ing holes from the pressurized environment. When installed plate with welded studs or a flange in order to isolate the mount-
properly, the EA 304 aiming device is capable of withstanding ing holes from the pressurized environment. When installed
pressures up to 0.5 bar (Europe) or 15 psi (North America). It properly, the EA 2 aiming device is capable of withstanding
can even be used in corrosive and aggressive environments. pressures up to 0.5 bar (Europe) or 15 psi (North America). It
can even be used in corrosive and aggressive environments.

■ Dimensional drawings ■ Dimensional drawings

1” NPT or BSP

3/4” NPT or BSP conduit x

5
300 mm (12”) long
170 mm clamping plate locknut
(6.7”) (upper socket)
mounting block angle block
(lower socket) conduit gland
10 mm
(0.38”)
customer gasket
(as required) sighting block
76 mm (3”)
nominal
127 mm 16 mm
(5”) Ø customer mounting (0.63”) mounting block
135 mm plate (as required)
(5.3”) typical
nominal customer gasket
(as required)
coupling/adapter

customer mounting
127 mm (5”) plate (as required)
Siemens Milltronics Ø typical
transducer (typical)

coupling /
adapter

Siemens Milltronics
transducer (typical)
max. 27°
max 20°

mounting hole - 3 places


11 mm (7/16”) on 157 mm mounting hole - 3 places
(6.2” ) bolt center diameter to suit M8 or 3/8”,
clamping screw (3 places) 120° apart on 157 mm
(6.2”) bolt center diameter

ground screw angle block binding


screw and clamp
sighting block binding
screw and clamp

178 mm
(7”)
ground screw
178 mm
(7.0”)

EA 304 aiming device dimensions EA 2 aiming device dimensions

5/164 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Accessories for ultrasonic
EA aiming devices

Selection and Ordering data Order No.


Easy aimer
Used on solids applications to aim transducers for
optimal performance. Available in a 304 stainless
steel model, or a cast aluminum model.
Easy Aimer 2, aluminum with M20 adapter and 1" 7ML1830-1AX
and 1½" BSPT aluminum couplings
Easy Aimer 304, with M20 adapter and 1" and 7ML1830-1GN
1½" BSPT 304 SS couplings
Easy Aimer 2, aluminum, BSPT conduit 7ML1830-1AL
Easy Aimer 2, aluminum, NPT with 1½" galvanized 7ML1830-1AN
coupling1)
Easy Aimer 2, aluminum, NPT with 1" galvanized 7ML1830-1AP
coupling
Easy Aimer 2, aluminum, NPT with ¾" x 1" PVC cou- 7ML1830-1AQ
pling
Easy Aimer 304, BSPT conduit 7ML1830-1AS
Easy Aimer 304, NPT with 1½" coupling1) 7ML1830-1AT
Easy Aimer 304, NPT with 1" coupling 7ML1830-1AU
Instruction manual
Easy Aimer 2 and 304 Instruction manual, 7ML1998-5HG62
Multi-language
Note: The instruction manual should be ordered as
a separate line item on the order.
This device is shipped with the Siemens Milltronics
5
manual CD containing the complete ATEX Quick
Start and instruction manual library.
1) For use with XPS-30 or XPS-40 transducers only

March 2009 Siemens FI 01 · 2009 US Edition 5/165


© Siemens AG 2009

Level instruments
Continuous level measurement - Accessories for ultrasonic
FMS mounting brackets

■ Application ■ Integration
Siemens mounting brackets permit simple, fast installation of ul-
trasonic transducers. These rugged, high quality mounting
brackets are constructed of 304 (1.4301) stainless steel and are FMS-200
suitable for use indoors and outdoors. They adjust to fit almost Universal Box Bracket
any application, saving you the time and expense of building
custom brackets. Each kit includes all mounting parts.
FMS-200
universal box bracket system
Mounting of units with 1" or 2" threaded connection.
Distance from sensor to wall or beam: 20 to 31 cm (8 to 12").
The unique box design also acts as a sun shield for transducers
with 1" threaded connections.
FMS-210
wall mounting set FMS-210
Channel Bracket,
Mounting of transducers with 1" threaded connection. Wall Mount

Distance from transducer to wall or beam: 12 to 48 cm (5 to 19").


FMS-220
extended wall mounting set
5 Mounting of transducers with 1" threaded connection.
Distance from transducer to wall or beam: 32 to 98 cm (13 to
39"). FMS-220
FMS-310 Extended Channel Bracket,
Wall Mount
floor mounting set
Mounting of transducers with 1" threaded connection.
Distance from transducer to floor: 20 to 48 cm (8 to 19").
Distance from mounting support: 5 to 57 cm (2 to 22").
FMS-320
extended floor mounting set
Mounting of transducers with 1" threaded connection. FMS-310
Channel Bracket,
Distance from transducer to floor: 20 to 48 cm (8 to 19").
Floor Mount
Distance from mounting support: 41 to 108 cm (16 to 43").
FMS-350
floor mounting set, bridge
Mounting of transducers with 1" threaded connection.
Distance from transducer to floor: 20 to 48 cm (8 to 19"), any-
where along the complete width of the bridge [166 cm (65")].
This kit is particularly suitable for measurements on open chan-
nels (OCM) by providing a very stable mount for the transducer FMS-320
above a flume or weir. Extended Channel Bracket,
Floor Mount
Selection and Ordering data Order No.
Mounting brackets for XPS-10/XCT-8 sensors
FMS-200 universal box bracket set 7ML1830-5BK
FMS-210 wall mounting set 7ML1830-1BL
FMS-220 extended wall mounting set 7ML1830-1BM
FMS-310 floor mounting set 7ML1830-1BN
FMS-320 extended floor mounting set 7ML1830-1BP
FMS-350 floor mounting set, bridge 7ML1830-1BQ
Additional instruction manual
FMS-200 7ML1998-5BK61
FMS-210 7ML1998-1BL61 FMS-350
Bridge Channel Bracket,
FMS-220 7ML1998-1BM61 Floor Mount
FMS-310 7ML1998-1BN61
FMS-320 7ML1998-1BP61
FMS-350 7ML1998-1BQ61
Note: The instruction manual should be ordered as
a separate line item on the order.
FMS mounting brackets

5/166 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Accessories for ultrasonic
TS-3 temperature sensor

■ Overview ■ Design

Clearance

conduit (supplied by others)

coupling (supplied by others)

TS-3
The TS-3 temperature sensor provides an input signal for tem-
perature compensation of specific Siemens ultrasonic level con-
trollers. plate or wall

■ Benefits
• Chemically resistant ETFE enclosure
• Fast response time locknut (supplied by others)
• Approved for use in potentially explosive atmospheres Note: Clearance Hole /

■ Application
Locknut Installation
method is not suitable 5
for pressure applications.
Temperature compensation is essential in applications where
temperature variations of the sound medium are expected.
By installing the temperature sensor close to the sound path of
the associated ultrasonic transducer, a signal representative of Tapped
the sound medium’s ambient temperature is obtained. The tem-
perature sensor should not be mounted in direct sunlight.
The TS-3 is used in conjunction with ultrasonic transducers that
do not have an integral temperature sensor. It is also recom-
mended in cases where the integral temperature sensor of the
transducer cannot be used.
The following conditions are typical for use of the TS-3 sensor:
where a fast reaction to temperature variations is required, where
a flanged ultrasonic transducer is used, or where high tempera-
tures are encountered.
The TS-3 is not compatible with devices using the TS-2 or LTS-1 flange or wall
temperature sensors. Refer to the associated transceiver man-
ual for more details.
• Key Applications: For use in applications where temperature
sensor measurement from transducer does not accurately
represent vessel temperature. Used for applications requiring
quick temperature response (open channel monitoring).

TS-3 temperature sensor

March 2009 Siemens FI 01 · 2009 US Edition 5/167


© Siemens AG 2009

Level instruments
Continuous measurement - Accessories for ultrasonic
TS-3 temperature sensor

■ Technical specifications ■ Dimensional drawings


Mode of operation
Measuring principle Temperature sensor
Input
Measuring range -40 to +150 °C (-40 to + 302 °F)
Output
Response time
• Forced circulation (temperature 55 seconds
variation: 63 %)
• Flange, forced circulation 90 seconds
• Natural convection 150 seconds
Rated operating conditions
• Installation instructions Mounted indoors/outdoors, but
not exposed to direct sunlight
• Pressure Max. 4 bar (60 psi/400 kPa)
Design
Material (enclosure) ETFE1)
Cable connection 2-core, 0.5 mm² (20 AWG),
shielded, silicone sheath
5 Process connection ¾“ NPT [(Taper), ANSI/ASME
B1.20.1]
R ¾“ [(BSPT), EN 10226], totally TS-3 temperature sensor dimensions
encapsulated
Certificates and approvals SAA, FM, CSA, ATEX
1)
ETFE is a fluoropolymer inert to most chemicals. For exposure to specific
environments, check the chemical compatibility charts before installing the
TS-3 in your application.

Selection and Ordering data Order No.


TS-3 temperature sensor C) 7 M L 1 8 1 3 -
TS-3 provides an input signal for temperature com- 77B7
pensation of specific Siemens ultrasonic level con-
trollers.
Compensation is essential in applications where
variation in temperature of the sound medium is
expected.
Cable length
1 m (3.28 ft) 1
5 m (16.40 ft) 2
10 m (32.81 ft) 3
30 m (98.43 ft) 4
50 m (164.04 ft) 5
70 m (229.66 ft) 6
90 m (295.28 ft) 7
Process connection
¾" NPT [(Taper), ANSI/ASME B1.20.1] A
R ¾" [(BSPT), EN 10226] B
Approvals
CSA, FM 3
ATEX, SAA 4
Instruction manual
English C) 7ML1998-5EM01
German C) 7ML1998-1EM31
Note: The instruction manual should be ordered as
a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing ATEX Quick Starts and
instruction manuals.
Optional equipment
¾" NPT locknut, aluminum C) 7ML1930-1BE
Tag, stainless steel with hole, 12 x 45 mm 7ML1930-1BJ
(0.47 x 1.77") for fastening on sensors
C) Subject to export regulations AL: N, ECCN: EAR99

5/168 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
Radar transmitters

■ Overview ■ Mode of operation


Radar measurement technology is non-contacting and low Principle of Operation
maintenance. Because microwaves require no carrier medium,
they are virtually unaffected by the process atmosphere (vapour, Radar measurement technology measures the time of flight from
pressure, dust, or temperature extremes). Siemens offers a the transmitted signal to the return signal. From this time, dis-
choice of models to meet the specific needs of your application. tance measurement and level are determined.
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmit- Unlike ultrasonic measurement, radar technology does not re-
ter for continuous monitoring of liquids and slurries in storage quire a carrier medium and travels at the speed of light
vessels with nominal pressure and temperature, to a range of (300 000 000 m/s). Most industrial radar devices operate from 6
20 m (66 ft). to 26 GHz.
SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter Siemens offers pulse radar transmitters (SITRANS Probe LR,
for continuous monitoring of liquids and slurries in storage and SITRANS LR200, SITRANS LR250, SITRANS LR260, SITRANS
process vessels including high temperature and pressure, to a LR300) and FMCW (Frequency Modulated Continuous Wave)
range of 20 m (66 ft). radar transmitters (SITRANS LR400, SITRANS LR460).
SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and Pulse radar emits a microwave pulse from the antenna at a fixed
process vessels including high temperature and pressure, to a repetition rate that reflects off the interface between the two ma-
range of 20 m (66 ft). Ideal for small vessels and low dielectric terials with different dielectric constants (the atmosphere and the
media. material being monitored). The echo is detected by a receiver
and the transmit time is used to calculate level.
SITRANS LR260 is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of solids in silos to a range of 30 m Reflected echoes are digitally converted to an echo profile. The
(98.4 ft). Ideal for applications with extreme dust and high tem- profile is analyzed to determine the distance from the material
peratures to +200 °C (+392 °F). surface to the reference point on the instrument.
SITRANS LR300 is a 4-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
FMCW (Frequency Modulated Continuous Wave) radar devices
send microwaves to the surface of the material. The wave freq-
5
process vessels including high temperature and pressure, to a uency is modulated continuously. At the same time, the receiver
range of 20 m (66 ft). is also receiving continuously and the difference in frequency
SITRANS LR400 is a 4-wire, 24 GHz FMCW radar level transmit- between the transmitter and the receiver is directly proportional
ter for continuous monitoring of liquids and slurries in storage to the distance to the material.
and process vessels including high temperature and high pres-
sure, to a range of 50 m (164 ft). It is ideal for low dielectric me-
dia.
SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level transmit-
ter with extremely high signal to noise ratio and advanced signal
processing for continuous monitoring of solids up to 100 m
(328 ft). It is ideal for measurement in extreme dust.
Auto False-Echo Suppression
SITRANS LR instruments offer the unique advantage of patented
Process Intelligence signal processing technology. This in-
depth knowledge and experience is built into the software’s ad-
vanced algorithms to provide intelligent processing of echo pro-
files. The result is repeatable, fast and reliable measurement.
A special feature of SITRANS radar devices is Auto False-Echo
Suppression, an echo processing technique that automatically
detects and suppresses false echoes from vessel obstructions.
You can implement this feature using two parameters on the lo-
cal interface or SIMATIC PDM communicating over HART® or
PROFIBUS PA.

Local display interface –graphically displays echo


profiles and diagnostic information (available with LR200,
LR250, LR260)

Quick to
configure
Quick Start Radar operation
Wizard via
SIMATIC
PDM guides
you during
setup
(available
with LR200,
LR250,
LR260,
LR460)

March 2009 Siemens FI 01 · 2009 US Edition 5/169


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
Radar transmitters

■ Technical specifications
Radar Selection Guide
Criteria SITRANS SITRANS LR200 SITRANS LR250 SITRANS LR260 SITRANS LR300 SITRANS LR400 SITRANS LR460
Probe LR
Typical industries Chemicals Chemicals, pet- Chemicals, Cement, power Chemicals, pet- Cement, petro- Cement, power
rochemicals petrochemicals generation, food rochemicals chemicals generation, food
processing, min- processing, min-
eral processing, eral processing,
mining mining
Typical applica- Liquids, storage Liquids, storage Liquids, storage Cement, plas- Liquids, process Liquids storage Cement, flyash,
tions vessels and process ves- and process ves- tics, grain, flour, vessels vessels, liquid grain, coal, flour,
sels sels with agita- coal petroleum gas plastics
tors, vaporous (LPG)
liquids, high tem-
peratures, low
dielectric media
Range 0.3 to 20 m 0.3 to 20 m 50 mm (2") from 30 m (98.4 ft) 0.4 to 20 m 0.35 to 50 m 100 m (328 ft)
(1 to 65 ft) (1 to 65 ft) end of horn to (1.3 to 65 ft) (1.14 to 164 ft)
20 m (65 ft), horn
dependent
Frequency 5.8 GHz 5.8 GHz K-band K-band 5.8 GHz 24 to 25 GHz 24 to 25 GHz
(North America (North America (25.0 GHz) (25.0 GHz) (North America FMCW FMCW
6.3 GHz) 6.3 GHz) 6.3 GHz)

5 Performance
accuracy
0.1% of range or 0.1% of range or 5 mm (0.02")
10 mm (0.4") 10 mm (0.4")
25 mm (1") from
minimum detect-
±15 mm (0.6")
from 0.4 to 10 m
≤ 5 mm (0.2")
from 2 to 10 m
0.25 %

able distance to (1.3 to 32.8 ft) (6.6 to 32.8 ft)


300 mm (11.8") ±0.15% from ≤ 15 mm (0.6")
Remainder of 10 to 20 m from 10 to 50 m
range = 10 mm (1.3 to 65 ft) (32.8 to 164 ft)
(0.39") or 0.1% of
span (whichever
is greater)
Temperature Ambient: Ambient: Ambient: Ambient: Ambient: Ambient: Ambient: max.
-40 to +80 °C -40 to +80 °C -40 to +80 °C -40 to +80 °C -40 to +60 °C -40 to +65 °C +65 °C (+149 °F)
(-40 to +176 °F) (-40 to +176 °F) (-40 to +176 °F) (-40 to +176 °F) (-40 to +140 °F) (-40 to +149 °F) Process: max.
Process: Process: Process: Process: Process: Process: +200 °C
-40 to +80 °C -40 to +200 °C -40 to +200 °C -40 to +200 °C -40 to +200 °C -40 to +250 °C (+392 °F)
(-40 to +176 °F (-40 to +392 °F), (-40 to +392 °F) (-40 to +392 °F) (-40 to +392 °F), (-40 to +482 °F),
dependent on dependent on dependent on dependent on dependent on
antenna type antenna type antenna type antenna type antenna type
Output/Commu- • 4 to 20 • 4 to 20 • 4 to 20 • 4 to 20 • 4 to 20 • 4 to 20 • 4 to 20
nications mA/HART® mA/HART mA/HART mA/HART mA/HART mA/HART mA/HART
• SIMATIC PDM • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA • PROFIBUS PA
for remote con- • SIMATIC PDM • SIMATIC PDM • SIMATIC PDM • Modbus • SIMATIC PDM • SIMATIC PDM
figuration and for remote con- for remote con- for remote con- ASCII/RTU for remote con- for remote con-
diagnostics figuration and figuration and figuration and figuration and figuration and
• SIMATIC PDM
diagnostics diagnostics diagnostics for remote con- diagnostics diagnostics
figuration and
diagnostics
Power • 4 to 20 mA, • 4 to 20 mA • 4 to 20 mA • 4 to 20 mA • Universal • 120 to 230 V • 100 to 230 V
24 V DC nomi- loop, 24 V DC loop, 24 V DC (±0.02 mA ac- AC/DC AC, ±15%, AC, ±15%,
nal, nominal, nominal, curacy) • 24 to 230 V AC, 50/60 Hz 50/60 Hz, 6 W
30 V DC max. 30 V DC max. 30 V DC max. 24 V DC nomi- ±15%, • 24 V DC, • 24 V DC,
• Minimum volt- • Minimum volt- • Minimum volt- nal, 40 to 70 Hz, +25/-20%, 6 W +25/-20%, 6 W
age depends age depends age depends 30 V DC max. 28 VA/11W (optional )
on total loop re- on total loop re- on total loop re- • Minimum volt- • 24 to 230 V DC,
sistance sistance sistance age depends ±15%, 9W
on total loop re-
sistance

Approvals CE, CSAUS/C, CE, CSAUS/C, CSAUS/C, CE, FM CSAUS/C, CE, FM CE, CSANRTL/C, CE, CSAUS/C, CSAUS/C, CE, FM
FM, Lloyds Reg- FM, Lloyds Reg- FCC, Industry R&TTE, Industry FM, Lloyds Reg- FM, Lloyds Reg- R&TTE, Industry
ister of Ship- ister of Ship- Canada, R&TTE, Canada, FCC, ister of Ship- ister of Ship- Canada, FCC,
ping, ABS, FCC, ping, ABS, FCC, ATEX, PED, ATEX, C-TICK ping, ABS, FCC, ping, ABS, FCC, ATEX, C-TICK
Industry Canada, Industry Canada, C-TICK Industry Canada, Industry Canada,
R&TTE, ATEX, R&TTE, ATEX, R&TTE, ATEX, R&TTE, ATEX,
PED, C-TICK PED, C-TICK 3A, PED, C-TICK PED, C-TICK

5/170 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
Radar transmitters

7ML5830-2AH 7ML5830-2AJ 7ML1930-1BK

1 2 3 4

5 6 7 8
mA

9 0
P PX X X

C % C C

SITRANS Probe LR SITRANS LR400 SITRANS LR200


SITRANS LR300 SITRANS LR460 SITRANS LR250
SITRANS LR260
Handheld Programmer Selection Guide

March 2009 Siemens FI 01 · 2009 US Edition 5/171


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
Radar transmitters

5/172 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS Probe LR

■ Overview ■ Configuration

5
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmit-
ter for continuous monitoring of liquids and slurries in storage
vessels with nominal pressure and temperature, to a range of
20 m (66 ft).

■ Benefits
• Uni-Construction polypropylene rod antenna standard
• Easy installation and simple startup
• Programming using infrared Intrinsically Safe handheld pro-
grammer, SIMATIC PDM or HART® handheld communicator
• Communication using HART®
• Patented Process Intelligence® signal processing
• Extremely high signal-to-noise ratio
• Auto False-Echo Suppression of false echoes

■ Application
The Probe LR is ideal for applications with chemical vapours,
temperature gradients, vacuum or pressure, such as tank farms,
chemical storage, digesters and long-range applications.
SITRANS Probe LR has a range of 0.3 to 20 m (1 to 65 ft).
Probe LR is designed for safe and simple programming using
the Intrinsically Safe handheld programmer without having to
open the instrument’s lid. It has a standard Uni-Construction
polypropylene rod antenna that offers excellent chemical resis-
tance and is hermetically sealed. The Uni-Construction antenna
includes an internal, integrated shield that eliminates vessel noz-
zle interference. SITRANS Probe LR incorporates Process Intel-
ligence® signal processing. The Probe LR also has a high sig- SITRANS Probe LR installation
nal-to-noise ratio leading to improved reliability.
Start-up is easy with as few as two parameters for basic opera-
tion. Programming is simple using SIMATIC PDM, HART® hand-
held communicator or the Intrinsically Safe handheld
programmer.
• Key Applications: tank farms, chemical storage, wastewater
wet well

March 2009 Siemens FI 01 · 2009 US Edition 5/173


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS Probe LR

■ Technical specifications Certificates and approvals


General CSAUS/C, CE, FM, C-TICK
Mode of operation
Marine • Lloyd’s Register of Shipping
Measuring principle Pulse radar level measurement
• ABS Type Approval
Frequency 5.8 GHz (North America 6.3 GHz)
Radio FCC, Industry Canada and Euro-
Measuring range 0.3 to 20 m (1.0 to 65 ft) pean (R&TTE), C-TICK
Output Hazardous
Analog output 4 to 20 mA • Europe ATEX II 1G EEx ia IIC T4
Accuracy ± 0.02 mA • USA Intrinsically Safe barrier required
Span Proportional or inversely propor- FM Class I, Div.1,
tional Groups A,B,C,D; Class II, Div. 1,
Groups E,F, G; Class III
Communications HART®
• Canada Intrinsically Safe barrier required
Performance (reference conditions) CSA Class I, Div.1,
Groups A,B,C,D; Class II, Div. 1,
Accuracy ± the greater of 0.1% of range or Group G; Class III
10 mm (0.4")
• Brazil - INMETRO BR-Ex ia IIC T4
Influence of ambient temperature 0.003%/K
Programming
Repeatability ± 5 mm (2")
Handheld programmer HART communicator 375
Fail-safe mA signal programmable as high,
low or hold (LOE) PC SIMATIC PDM
Rated operating conditions Intrinsically safe Siemens handheld Infrared receiver
5 • Installation conditions
programmer (optional)
• Approvals (handheld program- ATEX II 1G EEx ia IIC T4
- Location Indoor/outdoor mer) CSA and FM Class I, Div.1,
• Ambient conditions (enclosure) Groups A,B,C,D, T6 @ max. ambi-
- Ambient temperature -40 to +80 °C (-40 to +176 °F) ent

- Installation category I Display (local) Multi-segment alphanumeric liq-


uid crystal with bar graph (repre-
- Pollution degree 4 senting level) available in four
languages
Medium conditions
Dielectric constant εr εr > 1.6 (for εr < 3, use stillpipe) HART® is a registered trademark of the Hart Communications Foundation.
Vessel temperature -40 to +80 °C (-40 to +176 °F)
Vessel pressure 3 bar g (43.5 psi g)
Design
• Enclosure
- Body construction PBT (Polybutylene Terephthalate)
- Lid construction PEI (Polyether Imide)
- Cable inlet 2 x M20x1.5 or 2 x ½" NPT with
adapter
• Degree of protection Type 4X/NEMA 4X, Type 6/NEMA
6, IP67, IP68
• Weight 1.97 kg (4.35 lb)
• Antenna
- Material Polypropylene rod, hermetically
sealed construction
- Dimensions Standard 100 mm (4") shield for
maximum 100 mm (4") nozzle or
optional 250 mm (10") long shield
• Process connections 1½" NPT [(Taper), ANSI/ASME
B1.20.1]
R 1½" [(BSPT), EN 10226]
G 1½" [(BSPP), EN ISO 228-1]
Power supply • Nominal 24 V DC with max.
550 Ω, maximum 30 V DC
• 4 to 20 mA

5/174 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS Probe LR

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS Probe LR C) 7ML 5 4 3 0 - SITRANS Probe LR C) 7ML 5 4 3 0 -
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage 7777 0 tinuous monitoring of liquids and slurries in storage 7777 0
vessels with nominal pressure and temperature, to vessels with nominal pressure and temperature, to
a range of 20 m (66 ft). a range of 20 m (66 ft).
Max. 3 bar g (43.5 psi g) pressure and +80 °C Max. 3 bar g (43.5 psi g) pressure and +80 °C
(+176 °F) (+176 °F)
Enclosure Optional equipment
Plastic, (PBT), 2 x ½" NPT 1 Handheld programmer, Intrinsically Safe, 7ML5830-2AH
Plastic, (PBT), 2 x M20x1.5 2 ATEX II 1G, EEx ia
Antenna type/Material - (max. 3 bar and +80 °C) HART® modem/RS-232 (for use with a PC and D) 7MF4997-1DA
SIMATIC PDM)
Polyproylene Antenna HART modem/USB (for use with a PC and D) 7MF4997-1DB
1½" NPT [(Taper), ANSI/ASME B1.20.1], c/w inte- A SIMATIC PDM)
gral 100 mm shield One metallic cable gland M20x1.5, 7ML1930-1AP
R 1½" [(BSPT), EN 10226], c/w integral 100 mm B rated -40 to +80 °C (-40 to +176 °F)
shield SITRANS RD100 Remote display - see RD100 on
G 1½" [(BSPP), EN ISO 228-1], c/w integral C page 5/292
100 mm shield SITRANS RD200 Remote display - see RD200 on
1½" NPT [(Taper), ANSI/ASME B1.20.1], c/w inte- D page 5/294
gral 250 mm shield Spare parts
R 1½" [(BSPT), EN 10226], c/w integral 250 mm E Plastic lid C) 7ML1830-1KB
shield
1)
G 1½" [(BSPP), EN ISO 228-1], c/w integral F Includes European Radio approvals (R&TTE), 5.8 GHz, C-TICK
250 mm shield 2)
Includes FCC Radio approvals, 6.3 GHz for North America only
Approvals
General Purpose, CE1) A C) Subject to export regulations AL: N, ECCN: EAR99 5
General Purpose, FM, CSAUS/C2) B D) Subject to export regulations AL: N, ECCN: EAR99H
CSA Class I, Div 1, Groups A, B, C, D, Class II, Div. C
1 Group G, Class III, Intrinsically Safe with suitable
barrier2)
FM, Class I, II and III, Div 1, Groups A, B, C, D, E, F, D
G, Intrinsically Safe with suitable barrier2)
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with suit- E
able barrier1)
Communication/Output
4 to 20 mA, HART® 1
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters) specify in plain text
Test certificate: Manufacturer's test certificate M to C11
DIN 55350, Part 18 and to ISO 9000
Instruction manual Order No.
English C) 7ML1998-5HR02
French C) 7ML1998-5HR11
Spanish C) 7ML1998-5HR21
German C) 7ML1998-5HR31
Note: The instruction manual should be ordered as
a separate item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Additional quick start manual
Multi-language Quick Start manual C) 7ML1998-5QP81

March 2009 Siemens FI 01 · 2009 US Edition 5/175


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS Probe LR

■ Dimensional drawings

SITRANS Probe LR dimensions

■ Schematics

SITRANS Probe LR connections

5/176 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

■ Overview

SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter


for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, to a
range of 20 m (66 ft).
5
■ Benefits
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• Communication using HART® or PROFIBUS PA
• Process Intelligence signal processing for improved measure-
ment reliability and Auto False-Echo Suppression of fixed ob-
structions
• Programming using infrared Intrinsically Safe handheld pro-
grammer or SIMATIC PDM

■ Application
SITRANS LR200’s unique design allows safe and simple pro-
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid. It also features a
built-in alphanumeric display in four languages.
The SITRANS LR200 has a standard Uni-Construction polypro-
pylene rod antenna that offers excellent chemical resistance and
is hermetically sealed. The Uni-Construction antenna features
an internal, integrated shield that eliminates vessel nozzle inter-
ference.
Start-up is easy with as few as two parameters for basic opera-
tion. Installation is simplified as the electronics are mounted on
a rotating head that swivels, allowing the instrument to line up
with conduit or wiring connections or simply to adjust the posi-
tion for easy viewing. SITRANS LR200 features patented Pro-
cess Intelligence signal-processing technology for superior reli-
ability.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, high temperatures, asphalt,
digesters

March 2009 Siemens FI 01 · 2009 US Edition 5/177


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

■ Configuration
Installation Mounting unit on bypass Mounting unit on stilling well
min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall. Orient front or
back of device
toward vent.
optimum Orient front or
diameter back of device
80 mm (3”) toward stillpipe
slots.

beam
angle
20°

5 Mounting unit on vessel


Fl at
Mounting on a manhole cover Mounting on a nozzle

Coni

Flat
Conical
Parabolic
minimum 10 mm (0.4”)
minimum
100 mm (4”)

SITRANS LR200 installation

5/178 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

■ Technical specifications Process connections


• Process connection 1½" NPT [(Taper), ANSI/ASME
Mode of operation B1.20.1]
Measuring principle Radar level measurement R 1½" [(BSPT), EN 10226], or
Frequency 5.8 GHz (North America 6.3 GHz) G 1½" [(BSPP), EN ISO 228-1]
(polypropylene rod antenna)
Measuring range 0.3 to 20 m (1.0 to 65 ft)
• Flange connection Refer to SITRANS LR200/LR300
Output Antennas for more connections
• Analog output 4 to 20 mA Power supply
• Accuracy ± 0.02 mA 4 to 20 mA/HART
• Span Proportional or inversely propor- - General Purpose, Non-incen- Nominal 24 V DC (max. 30 V DC)
tional dive, Intrinsically Safe with max. 550 Ω
• Communications HART® - Flame proof, Increased safety, Nominal 24 V DC (max. 30 V DC)
Optional: PROFIBUS PA (Profile Explosion proof with max. 250 Ω
3.0, Class B)
PROFIBUS PA • 10.5 mA
• Fail-safe Programmable as high, low or • per IEC 61158-2
hold (Loss of Echo)
Certificates and approvals
Performance (according to reference conditions IEC60770-1)
• General CSAUS/C, CE, FM, C-TICK
• From end of antenna to 600 mm: 40 mm (1.57")
• Marine • Lloyd’s Register of Shipping
• Remainder of range: 10 mm (0.4") or 0.1% of span
(whichever is greater) • ABS Type Approval
Rated operating conditions
Installation conditions
• Radio FCC, Industry Canada and Euro-
pean (R&TTE), C-TICK 5
• Hazardous
• Location Indoor/outdoor
- Flame proof (Europe) ATEX II 1/2 G EEx dm ia IIC T4
Ambient conditions (enclosure)
- Increased safety (Europe) ATEX II 1/2 G EEx em ia IIC T4
• Ambient temperature -40 to +80 °C (-40 to +176 °F)
- Explosion proof (USA/Canada) CSA/FM (barrier not required) T4,
• Installation category I Class I, Div. 1, Groups A, B, C, D;
• Pollution degree 4 Class II, Div. 1, Groups E, F, G;
Class III
Medium conditions
- Non-incendive (USA) FM (barrier not required) T5,
• Dielectric constant εr εr > 1.6 (for εr < 3, use Class I, Div. 2, Groups A, B, C, D
waveguide antenna or stillpipe)
- Intrinsically Safe (Europe) ATEX II 1G EEx ia IIC T4
• Vessel temperature and pressure Varies with connection type; see
Pressure/Temperature curves for - Intrinsically Safe (USA/Canada) CSA/FM (barrier required) T4,
more information Class I, Div. 1, Groups A, B, C, D;
Class II, Div. 1, Groups E, F, G;
Design Class III
• Enclosure - Intrinsically Safe (Australia) ANZEX Ex ia IIC T4 [Tamb = -40 to
+80 °C (-40 to +176 °F)] IP67
- Material Aluminium, polyester powder
coated - Intrinsically Safe (International) IECEX TSA 04.0020X T4
- Cable inlet 2 x M20x1.5 or 2 x ½" NPT with • Brazil - INMETRO BR-Ex ia IIC T4
adapter
Programming
• Degree of protection Type 4X/NEMA 4X, Type 6/ NEMA
6, IP67, IP68 • Intrinsically Safe Siemens hand- Infrared receiver
held programmer
• Weight < 2 kg (4.4 lbs) (polypropylene
rod antenna) - Approvals for handheld pro- IS model with ATEX EEx ia IIC T4,
grammer CSA/FM Class I, Div. 1, Groups A,
• Display (local) Multi-segment alphanumeric liq- B, C, D
uid crystal with bar graph (repre-
senting level) available in four • Handheld communicator HART communicator 375
languages • PC SIMATIC PDM
• Antenna • Display (local) Multi-segment alphanumeric liq-
- Material Polypropylene rod, hermetically uid crystal with bar graph (repre-
sealed construction, optional senting level) available in four
PTFE languages

- Dimensions Standard 100 mm (4") shield for HART® is a registered trademark of the Hart Communications Foundation.
maximum 100 mm (4") nozzle, or
optional 250 mm (10") long shield
- Optional rods, horn and Refer to SITRANS LR200/LR300
waveguides Antennas for optional rods, horns
and waveguides

March 2009 Siemens FI 01 · 2009 US Edition 5/179


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR200, Uni-Construction C) 7ML 5 4 2 2 - SITRANS LR200, Uni-Construction C) 7ML 5 4 2 2 -
polypropylene rod antenna version 7777 0 polypropylene rod antenna version 7777 0
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Max. 3 bar g (43.5 psi g) pressure and +80 °C Max. 3 bar g (43.5 psi g) pressure and +80 °C
(+176 °F) (+176 °F)
Enclosure/Cable inlet Instruction manual for PROFIBUS PA device
Aluminum, Epoxy painted English C) 7ML1998-5JR01
2 x ½" NPT, Siemens LUI interface 2 German C) 7ML1998-5JR31
2 x M20x1.5, Siemens LUI interface 3 Note: The instruction manual should be ordered
Polypropylene antenna type - (Max. 3 Bar pres- as a separate line item on the order.
sure and +80 °C) Multi-language Quick Start manual C) 7ML1998-5XD81
1½" NPT [(Taper), ANSI/ASME B1.20.1], A This device is shipped with the Siemens Milltronics
c/w integral 100 mm shield manual CD containing the complete ATEX Quick
R 1½" [(BSPT), EN 10226], B Start and instruction manual library.
c/w integral 100 mm shield
G 1½" [(BSPP), EN ISO 228-1], C Accessories
c/w integral 100 mm shield Handheld programmer, Intrinsically safe, EEx ia C) 7ML1930-1BK
1½" NPT [(Taper), ANSI/ASME B1.20.1], D HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
c/w integral 250 mm shield SIMATIC PDM)
R 1½" [(BSPT), EN 10226], E HART modem/USB (for use with a PC and D) 7MF4997-1DB
c/w integral 250 mm shield SIMATIC PDM)
One metallic cable gland M20x1.5, 7ML1930-1AP
5
G 1½" [(BSPP), EN ISO 228-1], F
c/w integral 250 mm shield rated -40 °C to +80 °C (-40 to +176 °F) for General
Purpose or ATEX EEx e installations (available for
Approvals HART only)
General Purpose, CE1) A One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
General Purpose, CSAUS/C, FM, for North America B +80 °C (-40 °F to +176 °F) with integrated shield
only2) connection (available for PROFIBUS PA)
CSA Class I and II, Div. I, Groups A, B, C, D, G, C One General Purpose polymeric cable gland 7ML1930-1AM
6.3 GHz, for North America only, Intrinsically Safe M20x1.5, rating for -20 to +80 °C (-4 to +176 °F)
with suitable barrier 2) SITRANS RD100 Remote display - see RD100 on
FM, Class I and II, Div. I, Groups A, B, C, D, E, F, G, D page 5/292
for North America only, Intrinsically Safe with suit- SITRANS RD200 Remote display - see RD200 on
able barrier2) page 5/294
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with E 1)
suitable barrier1) Includes European Radio approval (R&TTE), 5.8 GHz, C-TICK
2)
FM, Class I, Div. 2, Groups A, B, C, D, for North F Includes Radio approval FCC, 6.3 GHz
3) Available with enclosure option 2 only
America only (no barrier required)2) 3) 4) Available with enclosure option 3 only
ATEX II 1/2 G EEx em ia IIC T4 (no barrier G 5)
Available with communication option 1 only
required)1) 4) 5)
ATEX II 1/2 G EEx dm ia IIC T4 (no barrier H C) Subject to export regulations AL: N, ECCN: EAR99
required)1) 5) D) Subject to export regulations AL: N, ECCN: EAR99H
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, J
E, F, G (no barrier required)2) 3) 5)
Communication/Output
4 to 20 mA, HART® 1
PROFIBUS PA 2
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
Test certificate: Manufacturer's test certificate M to C11
DIN 55350, Part 18 and to ISO 9000
Instruction manual for HART/mA device
English C) 7ML1998-5JP01
German C) 7ML1998-5JP31
Note: The instruction manual should be ordered
as a separate line item on the order.
Multi-language Quick Start manual C) 7ML1998-5XC81
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.

5/180 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR200, Flange Adapter, Sanitary C) 7ML 5 4 2 4 - SITRANS LR200, Flange Adapter, Sanitary C) 7ML 5 4 2 4 -
Version 7 7 7 77 - 77 7 7 Version 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna material (uses antenna adapter) Instruction manual for HART/mA device
PTFE, one piece rod antenna 0 English C) 7ML1998-5JP01
UHMW-PE, one piece rod antenna 1 German C) 7ML1998-5JP31
Process connection Note: The instruction manual should be ordered
Sanitary fitting clamp A as a separate line item on the order.
Configuration/Connection size Multi-language Quick Start manual C) 7ML1998-5XC81
2" connection, rod antenna only A This device is shipped with the Siemens Milltronics
3" connection, rod antenna only B manual CD containing the complete ATEX Quick
4" connection, rod antenna only C Start and instruction manual library.
Antenna extension Instruction manual for PROFIBUS PA device
No extension 0 English C) 7ML1998-5JR01
German C) 7ML1998-5JR31
Mounting Clamp
Note: The instruction manual should be ordered
No mounting clamp 0
as a separate line item on the order.
Mounting clamp included, not available with 1
Pressure rating option 0 Multi-language Quick Start manual C) 7ML1998-5XD81

Enclosure/Cable inlet This device is shipped with the Siemens Milltronics


Aluminum, Epoxy painted manual CD containing the complete ATEX Quick
2 x ½" NPT, Siemens LUI interface Start and instruction manual library.
5
2
2 x M20x1.5, Siemens LUI interface 3 Accessories
Communication/Output Handheld programmer, Intrinsically safe, EEx ia C) 7ML1930-1BK
4 to 20 mA, HART® A HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
PROFIBUS PA B SIMATIC PDM)
Approvals HART modem/USB (for use with a PC and D) 7MF4997-1DB
General Purpose, CE1) A SIMATIC PDM)
General Purpose, CSAUS/C, FM, for North America D) B One metallic cable gland M20x1.5, 7ML1930-1AP
only2) rated -40 °C to +80 °C (-40 to +176 °F) for General
CSA Class I and II, Div. I, Groups A, B, C, D, G, for D) C Purpose or ATEX EEx e installations (available for
North America only, Intrinsically Safe with suitable HART only)
barrier2) One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
+80 °C (-40 °F to +176 °F) with integrated shield
FM, Class I and II, Div. I, Groups A, B, C, D, E, F, G, D) D connection (available for PROFIBUS PA)
for North America only, Intrinsically Safe with suit- One General Purpose polymeric cable gland 7ML1930-1AM
able barrier2) M20x1.5, rating for -20 to +80 °C (-4 to +176 °F)
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with E SITRANS RD100 Remote display - see RD100 on
suitable barrier1) page 5/292
FM, Class I, Div. 2, Groups A, B, C, D, FCC D) F SITRANS RD200 Remote display - see RD200 on
6.3 GHz, for North America only (no barrier page 5/294
required) 3)
Sanitary fitting clamps
ATEX II 1/2 G EEx em ia IIC T4 (no barrier G 2", 304 stainless steel 7ML1830-1HD
required)1) 4) 5) 3", 304 stainless steel 7ML1830-1HE
ATEX II 1/2 G EEx dm ia IIC T4 (no barrier H 4", 304 stainless steel 7ML1830-1HF
required)1) 5)
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, D) 1)
J Includes European Radio approval (R&TTE), 5.8 GHz, C-TICK
E, F, G (no barrier required)2) 3) 5) 2)
Includes Radio approval FCC, 6.3 GHz
3)
Pressure rating Available with enclosure option 2 only
4)
Rating per Pressure/Temperature curves in Manual 0 Available with enclosure option 3 only
5)
0.5 bar g (7.25 psi g) maximum 1 Available with communication option A only
Further designs Order code C) Subject to export regulations AL: N, ECCN: EAR99
Please add “-Z" to Order No. and specify Order D) Subject to export regulations AL: N, ECCN: EAR99H
code(s).
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text

March 2009 Siemens FI 01 · 2009 US Edition 5/181


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR200, Flange Adapter/PTFE Rod C) 7 M L 5 4 2 3 - SITRANS LR200, Flange Adapter/PTFE Rod C) 7ML 5 4 2 3 -
Antenna Version 7 7 7 77 - 77 7 7 Antenna Version 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna material (uses antenna adapter) Approvals
PTFE, uses antenna adapter and additional pro- 1 General Purpose, CE2) A
cess connection below General Purpose, CSAUS/C, FM, for North America D) B
Process connection (refer to Pressure/Tempera- only3)
ture curves in Instruction manual) CSA Class I and II, Div. I, Groups A, B, C, D, G, for D) C
Flanges (316L stainless steel) North America only, Intrinsically Safe with suitable
DN 50 PN 16, Type A, flat faced AA barrier3)
DN 80 PN 16, Type A, flat faced BA FM, Class I and II, Div. I, Groups A, B, C, D, E, F, G, D) D
DN 100 PN 16, Type A, flat faced CA for North America only, Intrinsically Safe with suit-
DN 150 PN 16, Type A, flat faced DA able barrier3)
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with E
2" ASME 150 lb, flat faced FB suitable barrier2)
3" ASME 150 lb, flat faced GB FM, Class I, Div. 2, Groups A, B, C, D, FCC D) F
4" ASME 150 lb, flat faced HB 6.3 GHz, for North America only (no barrier
required) 3) 4)
6" ASME 150 lb, flat faced JB
DN 50 PN 40, flat faced AC ATEX II 1/2 G EEx em ia IIC T4 (no barrier G
DN 80 PN 40, flat faced BC required)2) 5) 6)
ATEX II 1/2 G EEx dm ia IIC T4 (no barrier H
DN 100 PN 40, flat faced CC
required)2) 6)
DN 150 PN 40, flat faced
5
DC
CSA/FM Class I, II and III, Div. 1, Groups A,B, C, D, D) J
2" ASME 300 lb, flat faced, available with FD E, F, G (no barrier required)2) 4) 6)
Pressure rating option 1 only
Pressure rating
3" ASME 300 lb, flat faced GD
Rating per Pressure/Temperature curves in Manual 0
4" ASME 300 lb, flat faced HD 0.5 bar g (7.25 psi g) maximum 1
6" ASME 300 lb, flat faced JD
Further designs Order code
JIS DN 50 10K AE
Please add “-Z" to Order No. and specify Order
JIS DN 80 10K BE
code(s).
JIS DN 100 10K CE
Acceptance test certificate: Manufacturer's test C11
JIS DN 150 10K DE
certificate M to DIN 55350, Part 18 and to ISO 9000
(Note: Flange bolting patterns and facings dimen-
Inspection Certificate Type 3.1 per EN 10204 C12
sionally correspond to the applicable ASME B16.5,
or EN 1092-1, or JIS B 2238 standard.) Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
Threaded connection (316L stainless steel)
characters); specify in plain text
1½" NPT [(Taper), ANSI/ASME B1.20.1] LA
Inactive custom shield lengths: Enter the total Y01
2" NPT [(Taper), ANSI/ASME B1.20.1] MA
length of the inactive shield in plain text description
R 1½" [(BSPT), EN 10226] LC
(in 1 mm increments).
R 2" [(BSPT), EN 10226] MC
Instruction manual for HART/mA device
G 1½" [(BSPP), EN ISO 228-1] LE
English C) 7ML1998-5JP01
G 2" [(BSPP), EN ISO 228-1] ME
German C) 7ML1998-5JP31
Antenna extensions or Inactive shield length Note: The instruction manual should be ordered
No antenna extension 0 as a separate line item on the order.
50 mm (2") extension, PTFE 1
Multi-language Quick Start manual C) 7ML1998-5XC81
100 mm (4") extension, PTFE 2
This device is shipped with the Siemens Milltronics
100 mm (4") extension, 316L stainless steel shield1) 3
manual CD containing the complete ATEX Quick
150 mm (6") extension, 316L stainless steel shield1) 4
1) Start and instruction manual library.
200 mm (8") extension, 316L stainless steel shield 5
250 mm (10") extension, 316L stainless steel 6
shield1)
Custom inactive shield length 101 mm to 1000 mm 7
(in 1 mm increments) Add order code Y01 and
1)
plain text: “Inactive shield length...mm"
Process seal/gasket
Integral Gasket, for flat faced flange process con- 0
nections only, not for Antenna extension options 3
to 6
FKM O-ring, not available for combination of flat 1
faced flanges with Antenna extension options 0, 1
or 2
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT, Siemens LUI interface 2
2 x M20x1.5, Siemens LUI interface 3
Communication/Output
4 to 20 mA, HART® A
PROFIBUS PA B

5/182 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

Selection and Ordering data Order No.


SITRANS LR200, Flange Adapter/PTFE Rod C) 7ML 5 4 2 3 -
Antenna Version 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Instruction manual for PROFIBUS PA device
English C) 7ML1998-5JR01
German C) 7ML1998-5JR31
Note: The instruction manual should be ordered
as a separate line item on the order.
Multi-language Quick Start manual C) 7ML1998-5XD81
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Handheld programmer, Intrinsically safe, EEx ia C) 7ML1930-1BK
HART modem/RS-232 (for use with a PC and D)
7MF4997-1DA
SIMATIC PDM)
HART modem/USB (for use with a PC and D) 7MF4997-1DB
SIMATIC PDM)
One metallic cable gland M20x1.5, 7ML1930-1AP
rated -40 °C to +80 °C (-40 to +176 °F) for General
Purpose or ATEX EEx e installations (available for
HART only)
Antenna, rod, PTFE
Antenna extension, 50 mm (2") PTFE
7ML1830-1HC
7ML1830-1CG
5
Antenna extension, 100 mm (4") PTFE 7ML1830-1CH
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
+80 °C (-40 to +176 °F) with integrated shield con-
nection (available for PROFIBUS PA)
One General Purpose polymeric cable gland 7ML1930-1AM
M20x1.5, rating for -20 to +80 °C (-4 to +176 °F)
SITRANS RD100 Remote display - see RD100 on
page 5/292
SITRANS RD200 Remote display - see RD200 on
page 5/294
1)
Available with process connection options BA, CA, DA, GB, HB, JB, BC,
CC, DC, GD, HD, JD, BE, CE, DE, MA, MC, ME only
2)
Includes European Radio approval (R&TTE), 5.8 GHz, C-TICK
3)
Includes Radio approval FCC, 6.3 GHz
4)
Available with enclosure option 2 only
5)
Available with enclosure option 3 only
6) Available with communication option A only
C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H

March 2009 Siemens FI 01 · 2009 US Edition 5/183


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR200, Flange Adapter/Horn Antenna C) 7ML 5 4 2 5 - SITRANS LR200, Flange Adapter/Horn Antenna C) 7 M L 5 4 2 5 -
Version 7 7 7 77 - 77 7 7 Version 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for con- 2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna Material (uses antenna adapter) 150 mm (6") horn with 250 mm (10") waveguide N
316L stainless steel with PTFE cone emitter 0 extension
316L stainless steel with PTFE cone emitter and 1 200 mm (8") horn with 100 mm (4") waveguide P
purge connection with 1/8" NPT inlet1) extension
Sliding waveguide system with 1000 mm (40") 2 200 mm (8") horn with 150 mm (6") waveguide Q
waveguide1) extension
Process connection (refer to Pressure/Tempera- 200 mm (8") horn with 200 mm (8") waveguide R
ture curves on specification sheets) extension
Flanges (316L stainless steel) 200 mm (8") horn with 250 mm (10") waveguide S
DN 50 PN 16, Type A, flat faced1) AA extension
DN 80 PN 16, Type A, flat faced BA Waveguide only - Waveguide length 500 mm to T
DN 100 PN 16, Type A, flat faced CA 3000 mm (in 1 mm increments) (Add order code
DN 150 PN 16, Type A, flat faced DA Y01 and plain text: “waveguide length ...mm")
DN 200 PN 16, Type A, flat faced EA Horn with custom waveguide lengths 101 to U
2000 mm (Add order codes Y01 and Y03 and plain
2" ASME 150 lb, flat faced1) FB
text: “waveguide length...mm",
3" ASME 150 lb, flat faced GB and “horn size ...mm")3)
4" ASME 150 lb, flat faced HB Approvals
6" ASME 150 lb , flat faced JB General Purpose, CE4)
5
A
8" ASME 150 lb, flat faced KB General Purpose, CSAUS/C, FM, for North America B
DN 50 PN 40, flat faced1) AC only5)
DN 80 PN 40, flat faced BC CSA Class I and II, Div. I, Groups A, B, C, D, G, for C
DN 100 PN 40, flat faced CC North America only, Intrinsically Safe with suitable
DN 150 PN 40, flat faced DC barrier5)
DN 200 PN 40, flat faced EC FM, Class I and II, Div. I, Groups A, B, C, D, E, F, G, D
2" ASME 300 lb, flat faced1) FD for North America only, Intrinsically Safe with suit-
3" ASME 300 lb, flat faced GD able barrier5)
ATEX II 1G EEx ia IIC T4, Intrinsically Safe with E
4" ASME 300 lb, flat faced HD suitable barrier4)
6" ASME 300 lb, flat faced JD FM, Class I, Div. 2, Groups A, B, C, D, for North F
8" ASME 300 lb, flat faced KD America only (no barrier required)5) 6)
JIS DN 50 10K1) AE ATEX II 1/2 G EEx em ia IIC T4 (no barrier G
JIS DN 80 10K BE required)4) 7) 8)
JIS DN 100 10K CE ATEX II 1/2 G EEx dm ia IIC T4 (no barrier H
JIS DN 150 10K DE required)4) 8)
JIS DN 200 10K EE CSA/FM Class I, II and III, Div. 1, Groups A B, C, D, J
(Note: Flange bolting patterns and facings dimen- E, F, G (no barrier required)5) 6) 8)
sionally correspond to the applicable ASME B16.5, Pressure rating
or EN 1092-1, or JIS B 2238 standard.) Rating per Pressure/Temperature curves in Manual 0
Communication/Output 0.5 bar g (7.25 psi g) maximum 1
4 to 20 mA, HART® 0 Further designs Order code
PROFIBUS PA 1
Please add “-Z" to Order No. and specify Order
Process seal/gasket code(s).
FKM (-40 to +200 °C) 0 Acceptance test certificate: Manufacturer's test C11
Nitrile (-40 to +100 °C), sliding waveguide sytems 1 certificate M to DIN 55350, Part 18 and to ISO 9000
only C12
FFKM (-35 to +200 °C) 2 Inspection Certificate Type 3.1 per EN 10204
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Enclosure/Cable inlet
Aluminum, Epoxy painted Measuring-point number/identification (max. 16
2 x ½" NPT, Siemens LUI interface 2 characters) specify in plain text
2 x M20x1.5, Siemens LUI interface 3 Waveguide custom lengths: Enter the total length of Y01
Horn size/Waveguide options the waveguide in plain text description (1 mm
80 mm (3") horn2) D) B increments)
100 mm (4") horn2) D) C Enter the waveguide length (100 mm to 1000 mm) Y03
150 (6") mm horn D)
D and enter the horn size (100 mm, 150 mm, and
200 (8") mm horn E 200 mm only) in plain text description
100 mm (4") horn with 100 mm (4") waveguide D) F Instruction manual for HART/mA device
extension2) English C) 7ML1998-5JP01
100 mm (4") horn with 150 mm (6") waveguide G German C) 7ML1998-5JP31
extension2) Note: The instruction manual should be ordered
100 mm (4") horn with 200 mm (8") waveguide H as a separate line item on the order.
extension2) Multi-language Quick Start manual C) 7ML1998-5XC81
100 mm (4") horn with 250 mm (10") waveguide D) J This device is shipped with the Siemens Milltronics
extension2) manual CD containing the complete ATEX Quick
150 mm (6") horn with 100 mm (4") waveguide K Start and instruction manual library.
extension
150 mm (6") horn with 150 mm (6") waveguide L
extension
150 mm (6") horn with 200 mm (8") waveguide M
extension

5/184 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

Selection and Ordering data Order No.


SITRANS LR200, Flange Adapter/Horn Antenna C) 7ML 5 4 2 5 -
Version 7 7 7 77 - 77 7 7
2-wire, 6 GHz pulse radar level transmitter for con-
tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Instruction manual for PROFIBUS PA device
English C) 7ML1998-5JR01
German C) 7ML1998-5JR31
Note: The instruction manual should be ordered
as a separate line item on the order.
C)
Multi-language Quick Start manual 7ML1998-5XD81
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Handheld programmer, Intrinsically safe, EEx ia C) 7ML1930-1BK
HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
SIMATIC PDM)
HART modem/USB (for use with a PC and D) 7MF4997-1DB
SIMATIC PDM®)
One metallic cable gland M20x1.5, rated -40 °C to 7ML1930-1AP
+80 °C (-40 to +176 °F) (available for HART only)
One metallic cable gland M20x1.5, rated -40 °C to 7ML1930-1AQ
+80 °C (-40 to +176 °F) with integrated shield con-
nection (available for PROFIBUS PA) 5
One General Purpose polymeric cable gland 7ML1930-1AM
M20x1.5, rating for -20 to +80 °C (-4 to +176 °F)
SITRANS RD100 Remote display - see RD100 on
page 5/292
SITRANS RD200 Remote display - see RD200 on
page 5/294
1)
Available with pressure rating option 1 only
2)
For stillpipe applications only
3)
Order standard waveguide lengths 100, 150, 200, 250 mm (3.93, 5.91,
7.87, 9.84") by choosing options from Horn size/Waveguide options
4)
Includes European Radio approval (R&TTE), 5.8 GHz, C-TICK
5)
Includes Radio approval FCC, 6.3 GHz
6)
Available with enclosure option 2 only
7)
Available with enclosure option 3 only
8) Available with communication option 0 only
C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H

■ Characteristic curves

Maximum Flange and Process Temperatures versus Allowable Ambient

90
Ambient temperature (°C)

80

70

60

50

40

30

20

10

0
0 50 100 150 200 250

Process Flange Surface Temperature (°C)

SITRANS LR200 Ambient/Process Flange Surface Temperature Curve

March 2009 Siemens FI 01 · 2009 US Edition 5/185


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

■ Dimensional drawings

SITRANS LR200 dimensions

5/186 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200

■ Schematics

Connect the wires


to the terminals as
shown: the polarity
is identified on the
terminal block.

Shield for HART and PROFIBUS PA Instrinsically


gland Safe versions only.
Notes:
1. DC terminal shall be supplied from an SELV source in accordance with IEC-1010-1 Annex H.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 to 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.

Hand Programmer 5
Part number:
7ML1930-1BK

SITRANS LR200 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/187


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR250

■ Overview ■ Configuration
Installation

beam width:
1.5” horn = 19°
2” horn = 15°
3” horn = 10°
19° 4” horn = 8°

SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter Mounting unit on bypass
for continuous monitoring of liquids and slurries in storage and Orient
process vessels including high temperature and pressure, to a front or
range of 20 m (66 ft).
5 back of
device
■ Benefits toward
vent.
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support Use largest
• 25 GHz high frequency allows for small horn antennas for easy horn size
mounting in nozzles possible
in pipe.
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference Mounting unit on stilling well
• Short blanking distance for improved minimum measuring
range to 50 mm (2") from the end of the horn Orient front or
back of device
• Communication using HART® or PROFIBUS PA toward stillpipe
• Process Intelligence signal processing for improved measure- slots.
ment reliability and Auto False-Echo Suppression of fixed ob-
structions Use
• Programming using infrared Intrinsically Safe handheld pro- largest
grammer or SIMATIC PDM horn size
possible
Mounting unit on vessel
in pipe.
■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic sup-
port. Startup is easy using the Quick Start wizard with a few pa-
rameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller horn options and decreasing sensitivity to obstruc-
tions.
SITRANS LR250’s unique design allows safe and simple pro-
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid. Mounting on a nozzle
SITRANS LR250 measures superbly on low dielectric media,
and in small vessels, as well as tall and narrow vessels.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, high temperatures, low di-
electric media

minimum 10 mm (0.4”)

SITRANS LR250 installation

5/188 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR250

■ Technical specifications Process connections


• Process connection 1½" or 2" NPT [(Taper),
Mode of operation ANSI/ASME B1.20.1]
Measuring principle Radar level measurement R 1½" or 2" [(BSPT), EN 10226]
Frequency K-band (25.0 GHz) G 1½" or 2" [(BSPP), EN ISO
228-1]
Minimum measuring range 50 mm (2") from end of horn
• Flange connection 2", 3", 4" (ANSI 150, 300 lbs),
Maximum measuring range 20 m (65 ft), horn dependent
50, 80, 100 mm (PN 16, 40, JIS
Output 10K)
• Analog output 4 to 20 mA Power supply
• Accuracy ± 0.02 mA 4 to 20 mA/HART Nominal 24 V DC (max. 30 V DC)
• Communications HART® with max. 550 Ω
Optional: PROFIBUS PA (Profile PROFIBUS PA • 15.0 mA
3.0, Class B) • per IEC 61158-2
Certificates and approvals
• Fail-safe • Programmable as high, low or
hold (Loss of Echo) • General CSAUS/C, CE, FM, NE 21, C-TICK
• NE 43 programmable • Radio FCC, Industry Canada and
Europe ETSI EN 302-372, C-TICK
Performance (according to reference conditions IEC60770-1) • Hazardous
• Maximum measured error 5 mm (0.2")

5
• Influence of ambient temperature <0.003 %/K - Intrinsically Safe (Europe) ATEX II 1G EEx ia IIC T4
ATEX II 1D EEx tD A20 IP67
Rated operating conditions T90 °C
Installation conditions - Intrinsically Safe (USA/Canada) CSA/FM (barrier required) Class I,
• Location Indoor/outdoor Div. 1, Groups A, B, C, D; Class II,
Div. 1, Groups E, F, G; Class III T4
Ambient conditions (enclosure)
- Intrinsically Safe (International) IECEX SIR 05.0031X, Ex ia IIC T4,
• Ambient temperature -40 to +80 °C (-40 to +176 °F) EX tD A20 IP67 T90 °C
• Installation category I - Non-incendive (USA/Canada) CSA/FM Class I, Div. 2, Groups A,
B, C, D T5
• Pollution degree 4
Programming
Medium conditions
• Intrinsically Safe Siemens hand- Infrared receiver
• Dielectric constant εr εr > 1.6, horn and application held programmer
dependent
- Approvals for handheld pro- IS model with ATEX II 1G EEx ia
• Process temperature -40 to +200 °C (-40 to +392 °F) (at grammer IIC T4, CSA/FM Class I, Div. 1,
process connection with FKM o- Groups A, B, C, D
ring)
• Handheld communicator HART communicator 375
• Process pressure Up to 40 bar g (580 psi g), pro-
cess connection and tempera- • PC SIMATIC PDM
ture dependent.
• Display (local) Graphic local user interface
See Pressure/Temperature curves including quick start wizard and
for more information echo profile displays
Design ®
HART is a registered trademark of the Hart Communications Foundation.
• Enclosure ®Hastelloy and ®C-22 are registered trademarks of Haynes International Inc.

- Material Aluminium, polyester powder-


coated
- Cable inlet 2 x M20x1.5 or 2 x ½" NPT
• Degree of protection Type 4X/NEMA 4X, Type 6/NEMA
6, IP67, IP68
• Weight < 3 kg (6.6 lbs) 3.75 mm (1½")
threaded connection with 1½"
horn antenna
• Display (local) Graphic local user interface
including quick start wizard and
echo profile display
• Antenna
- Material 316L stainless steel [optional
alloy N06022/2.4602 (Hastelloy®
C-22® or equivalent)]
- Dimensions (nominal horn sizes) Standard 1.5" (40 mm), 2"
(48 mm), 3" (75 mm), 4" (95 mm)
horn and optional 100 mm (4")
horn extension

March 2009 Siemens FI 01 · 2009 US Edition 5/189


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR250

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR250 C) 7ML 5 4 3 1 - SITRANS LR250 C) 7ML 5 4 3 1 -
2-wire, 25 GHz pulse radar level transmitter for con- 7 7 7 7 0 - 77 7 7 2-wire, 25 GHz pulse radar level transmitter for con- 7 7 7 7 0 - 77 7 7
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). Ideal for and pressure, to a range of 20 m (66 ft). Ideal for
small vessels and low dielectric media. small vessels and low dielectric media.
Process Connection and Antenna Material Further designs Order code
316L (1.4435 or 1.4404) stainless steel, PTFE emit- 0 Please add “-Z" to Order No. and specify Order
ter, FKM seal code(s).
316L (1.4435 or 1.4404) stainless steel, PTFE emit- 1
ter, FFKM seal Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and to ISO 9000
Hastelloy C-22/2.4602, PTFE emitter, FKM seal1) 2 C12
Hastelloy C-22/2.4602, PTFE emitter, FFKM seal1) 3 Inspection Certificate Type 3.1 per EN 10204
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Process Connection Type
1½" NPT [(Taper), ANSI/ASME B1.20.1]2) AA Measuring-point number/identification (max. 27
R 1½" [(BSPT), EN 10226]2) AB characters) specify in plain text
G 1½" [(BSPP), EN ISO 228-1] (parallel thread)2) AC Instruction manual for HART/mA device Order No.
2" NPT [(Taper), ANSI/ASME B1.20.1] AD English C) 7ML1998-5JE01
R 2" [(BSPT), EN 10226] AE German C) 7ML1998-5JE31
G 2" [(BSPP), EN ISO 228-1] (parallel thread) AF Note: The instruction manual should be ordered
as a separate line item on the order.
2" ASME, 150 lb BA
3" ASME, 150 lb BB Multi-language Quick Start manual C) 7ML1998-5QX81
4" ASME, 150 lb BC This device is shipped with the Siemens Milltronics
2" ASME, 300 lb manual CD containing the complete ATEX Quick
5
CA
3" ASME, 300 lb CB Start and instruction manual library.
4" ASME, 300 lb CC Instruction manual for PROFIBUS PA device
English C) 7ML1998-5JF02
DN 50 PN 16 DA
DN 80 PN 16 DB German C) 7ML1998-5JF32
Note: The instruction manual should be ordered
DN 100 PN 16 DC
as a separate line item on the order.
DN 50 PN 40 EA
Multi-language Quick Start manual C) 7ML1998-5XE81
DN 80 PN 40 EB
DN 100 PN 40 EC This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
JIS 50A 10K FA Start and instruction manual library.
JIS 80A 10K FB
JIS 100A 10K FC Accessories
(Note: Stainless steel flanges provided as flat Handheld programmer, Intrinsically Safe, EEx ia C) 7ML1930-1BK
faced; Hastelloy flanges provided as raised face. (LUI enabled)
Flange bolting patterns and facings dimensionally HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
correspond to the applicable ASME B16.5, or SIMATIC PDM)
EN 1092-1, or JIS B 2238 standard.) One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
Communication/Output +80 °C (-40 to +176 °F)
4 to 20 mA, HART® 0 One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
PROFIBUS PA 1 +80 °C (-40 to +176 °F), PROFIBUS PA
SITRANS RD100 Remote display - see RD100 on
Enclosure/Cable inlet page 5/292
Aluminum, Epoxy painted SITRANS RD200 Remote display - see RD200 on
2 x ½" NPT 0 page 5/294
2 x M20x1.5 1
1)
Antenna Not available with process connection options AA to AF
2)
For 1½" horn antennas only, max. range 10 m (32.8 ft), dk > 3
1½" horn3) A 3)
For 1½" threaded connection only, max. range 10 m (32.8 ft), dk > 3
2" horn (fits 2" ASME or DN 50 nozzles) B 4)
Applicable to HART version only
3" horn (fits 3" ASME or DN 80 nozzles) C
4" horn (fits 4" ASME or DN 100 nozzles) D C) Subject to export regulations AL: N, ECCN: EAR99
1½" horn with 100 mm extension2) E D) Subject to export regulations AL: N, ECCN: EAR99H
2" horn with 100 mm extension F
3" horn with 100 mm extension G
4" horn with 100 mm extension H
(Note: Please use largest horn size possible.)
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE, A
C-TICK
CSA/FM Class I and II, Div. I, Groups A, B, C, D, E, B
F, G Intrinsically Safe, barrier required, FCC,
C-TICK
ATEX II 1 GD EEx ia IIC T4, Intrinsically Safe, barrier C
required, R&TTE, C-TICK, INMETRO
CSA/FM Class I, Div. 2, Non-Incendive, no barrier D
required, FCC, C-TICK
ATEX II 3G Ex nA II T4, Non- Sparking, no barrier E
required, CE, R&TTE, C-TICK4)
Pressure rating
Rating per Pressure/Temperature curves in Manual 0
0.5 bar g (7.25 psi g) maximum 1

5/190 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR250

■ Selection and Ordering Data


SITRANS LR250 Spare parts
SITRANS LR250 Enclosures SITRANS LR250 enclosure with board stack, C) A5E01156839
NPT cable inlet, approval option B, with
PROFIBUS PA communication, no process
connection
SITRANS LR250 enclosure with board stack, C) A5E01156841
M20 cable inlet, approval option B, with
PROFIBUS PA communication, no process
connection
SITRANS LR250 enclosure with board stack, C) A5E01156819 SITRANS LR250 enclosure with board stack, C) A5E01156843
NPT cable inlet, approval option A, with HART NPT cable inlet, approval option C, with
communication, no process connection PROFIBUS PA communication, no process
connection
SITRANS LR250 enclosure with board stack, C) A5E01156820
M20 cable inlet, approval option A, with HART SITRANS LR250 enclosure with board stack, C) A5E01156844
communication, no process connection M20 cable inlet, approval option C, with
PROFIBUS PA communication, no process
SITRANS LR250 enclosure with board stack, C) A5E01156823 connection
NPT cable inlet, approval option B, with HART
communication, no process connection SITRANS LR250 enclosure with board stack, C) A5E01156846
NPT cable inlet, approval option D, with
SITRANS LR250 enclosure with board stack, C) A5E01156824 PROFIBUS PA communication, no process
M20 cable inlet, approval option B, with HART connection
communication, no process connection
SITRANS LR250 enclosure with board stack, C) A5E01156848
SITRANS LR250 enclosure with board stack, C) A5E01156827
NPT cable inlet, approval option C, with HART
communication, no process connection
M20 cable inlet, approval option D, with
PROFIBUS PA communication, no process
connection
5
SITRANS LR250 enclosure with board stack, C) A5E01156832 SITRANS LR250 enclosure with board stack, C) A5E02448270
M20 cable inlet, approval option C, with HART M20 cable inlet, approval option F, with Hart
communication, no process connection communication, no process connection
SITRANS LR250 enclosure with board stack, C) A5E01156834 SITRANS LR250 enclosure with board stack, C) A5E02448274
NPT cable inlet, approval option D, with HART M20 cable inlet, approval option G, with Hart
communication, no process connection communication, no process connection
SITRANS LR250 enclosure with board stack, C) A5E01156835 SITRANS LR250 enclosure with board stack, C) A5E02448278
M20 cable inlet, approval option D, with HART NPT cable inlet, approval option H, with Hart
communication, no process connection communication, no process connection
SITRANS LR250 enclosure with board stack, C) A5E01156836 SITRANS LR250 horn antenna and exten-
NPT cable inlet, approval option A, with PROFI- sion kits
BUS PA communication, no process connec-
tion
SITRANS LR250 enclosure with board stack, C) A5E01156838
M20 cable inlet, approval option A, with PROFI-
BUS PA communication, no process connec-
tion
38 mm (1.5") horn antenna kit C) A5E01151539

100 mm (4") horn antenna extension kit, Pro- A5E01151553


cess Connection
50 mm (2") stainless steel horn antenna kit C) A5E01151569

75 mm (3") stainless steel horn antenna kit C) A5E01151571

100 mm (4") stainless steel horn antenna kit C) A5E01151573

100 mm (4") horn antenna extension kit, 50 mm C) A5E01151577


(2"), 75 mm (3") and 100 mm (4") process con-
nection
50 mm (2") horn antenna kit, Hastelloy C-22 J) A5E01151584

75 mm (3") horn antenna kit, Hastelloy C-22 J) A5E01151585

100 mm (4") horn antenna kit, Hastelloy C-22 J) A5E01151587

5 Dupont 1Gr Polyback, PTFE grease kit C) A5E01151626

C) Subject to export regulations AL: N, ECCN: EAR99


J) Subject to export regulations AL: 9I999, ECCN: EAR99
Please contact nacc.smpi@siemens.com for special requests.

March 2009 Siemens FI 01 · 2009 US Edition 5/191


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR250

■ Characteristic curves

Maximum Flange and Process Temperatures versus Allowable Ambient

90
Ambient temperature (°C)

80

70

60

50

40

30

20

10

0
0 50 100 150 200 250

Process Flange Surface Temperature (°C)


5
SITRANS LR250 Ambient/Process Flange Surface Temperature Curve

5/192 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR250

■ Dimensional drawings

SITRANS LR250 dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/193


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR250

■ Schematics

Connect theder
Anschluss wires
Drähte
wiethe
to abgebildet:
terminals Die
as
Polaritätthe
shown: ist polarity
auf den
Klemmen
is identifiedgekenn-
on the
zeichnet.block.
terminal

Shield for
Schirm nurHART
für eigensichere
and PROFIBUS
HARTPAund
Instrinsically
Kabelverschraubung
gland PROFIBUS
Safe versionsPAonly.
Ausführungen.

Hinweise:
Notes:
1. Um die Sicherheitsanforderungen der IEC 61010-1 zu erfüllen, sind Gleichstromklemmen von einer Quelle zu versorgen, die eine galvanische Trennung zwischen Ein- und Ausgang bewirkt.
2. DC
1. Alleterminal
Feldanschlüsse
shall be müssen
suppliedentsprechend
from a sourceder angelegten
providing Eingangsspannung
electrical isoliert
isolation between sein.and output, to meet the applicable safety requirements of IEC 61010-1.
the input

5
3. All
2. Verwenden Siemust
field wiring geschirmtes Kabel mit
have insulation verdrilltem
suitable Aderpaar
for rated (14 ... 22 AWG) für die HART Ausführung.
input voltages.
4. Use
3. Eineshielded
getrenntetwisted
Leitungsverlegung
pair cable (14kann
to 22erforderlich sein, um
AWG) for HART Standardanforderungen an den Anschluss oder elektrische Richtlinien zu erfüllen.
version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
Handprogrammiergerät
Hand Programmer
SITRANS LR250
HART
Part number:
7ML1930-1BK
Artikelnummer:
7ML1930-1BK

SITRANS LR250 connections

5/194 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR260

■ Overview ■ Configuration

Mounting on a nozzle

Min. clearance:
10 mm (0.4")

Installation

5
min. 1 m (39")

SITRANS LR260 is a 2-wire 25 GHz pulse radar level transmitter


for continuous monitoring of solids in storage vessels including emission
extreme levels of dust and high temperatures, to a range of 30 cone
m (98.4 ft).

■ Benefits
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency allows for small horn antennas
mounted easily in nozzles
• Communication using HART® or PROFIBUS PA beam angle:
2" horn = 15°
• Process Intelligence signal processing for improved measure- 3" horn = 10°
ment reliability and Auto False-Echo Suppression of fixed ob- 4" horn = 8°
structions
• Programming using infrared Intrinsically Safe handheld pro-
grammer or SIMATIC PDM

■ Application Positioning with Easy Aimer


SITRANS LR260 includes a graphical local user interface (LUI)
that improves setup and operation using an intuitive Quick Start
Wizard, and echo profile displays for diagnostic support. Startup
is easy using the Quick Start wizard with a few parameters re-
quired for basic operation.
SITRANS LR260’s unique design allows safe and simple pro-
gramming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
SITRANS LR260 measures virtually any solids material to a
range of 30 m (98.4 ft).
• Key Applications: cement powder, plastic powder/pellets,
grain, flour, coal, solids bulk storage vessels, and other appli-
cations.

SITRANS LR260 installation

March 2009 Siemens FI 01 · 2009 US Edition 5/195


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR260

■ Technical specifications Process connections


• Universal flanges2) 2"/50 mm, 3"/80 mm, 4"/100 mm,
Mode of operation 6"/150 mm
Measuring principle Pulse radar level measurement Certificates and approvals
Frequency K-band (25.0 GHz) • General CSAUS/C, CE, FM
Minimum detectable distance 0.05 m (2") from end of horn • Radio Europe (R&TTE), FCC, Industry
Maximum measuring range1) • 2" horn: 10 m (32.8 ft) Canada, C-TICK
• 3" horn: 20 m (65.6 ft) • Hazardous CSA/FM Class II, Div. 1, Groups
• 4" horn: 30 m (98.4 ft) E, F, G, Class III

Output - HART ® ATEX II 1D, 1/2D, 2D Ex tD A20


IP67, IP68 T100 ºC
• Power • 4 to 20 mA (±0.02 mA accuracy)
Programming
• Nominal 24 V DC (max. 30 V DC)
• Intrinsically Safe Siemens hand- Infrared receiver
• Fail signal 3.6 mA to 23 mA; or last value held programmer
• Load 230 to 600 Ω, 230 to 500 Ω when - Approvals for handheld pro- Intrinsically safe, ATEX II 1G EEx
connecting a coupling module grammer ia IIC T4, CSA/FM Class I, Div. 1,
• Max. line length Multi-wire: ≤1500 m (4921 ft) Pro- Groups A, B, C, D
tocol HART, Version 5.1 • Handheld communicator HART communicator 375
Output - PROFIBUS PA • Per IEC 61158-2 • PC SIMATIC PDM
• 15.0 mA • Display (local) Graphic local user interface
• Profile version 3.01, Class B including quick start wizard and
5 Performance (according to refer-
ence conditions IEC60770-1) 1)
From sensor reference point
echo profile displays

2)
• Maximum measured error (includ- • 25 mm (1") from minimum de- Universal flange mates with EN 1092-1 (PN 16)/ASME B16.5 (150 lb)/JIS
ing hysteresis and non-repeatabil- tectable distance to 300 mm 2220 (10K) bolt hole pattern
®
ity) (11.8") HART is a registered trademark of the Hart Communications Foundation.
• Remainder of range = 10 mm
(0.39") or 0.1% of span (which-
ever is greater)
Rated operating conditions
Installation conditions
• Location Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature -40 to +80 °C (-40 to +176 °F)
• Installation category I
• Pollution degree 4
Medium conditions
• Dielectric constant εr εr > 1.6, antenna and application
dependent

• Process temperature -40 to +200 °C (-40 to +392 °F)


• Process pressure • 0.5 bar g (7.25 psi g) maximum
• 3 bar g (43.5 psi g) optional with
+80 °C (+176 °F) temperature
max.
Design
• Enclosure
- Construction Aluminium, polyester powder-
coated
- Conduit entry 2 x M20x1.5 or 2 x ½" NPT
• Degree of protection Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
• Weight < 8.14 kg (17.9 lb) including 4"
flange and standard Easy Aimer
with 4" horn antenna
• Display (local) Graphic LCD, with bar graph rep-
resenting level
• Flange and horn
- Material 304 stainless steel
- Dimensions (nominal horn sizes) 2" horn: 1.93" (49.0 mm) diameter
3" horn: 2.93" (74.5 mm) diameter
4" horn: 3.84" (97.5 mm) diameter

5/196 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR260

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR260 C) 7 M L 5 4 2 7 - 0 Instruction manual for PROFIBUS PA device
2-wire, 25 GHz pulse radar level transmitter for con- 7 7 7 0 - 77 7 7 English C) 7ML1998-5KF01
tinuous monitoring of solids to a range of 30 m German C) 7ML1998-5KF31
(98.4 ft). Note: The instruction manual should be ordered
as a separate line item on the order.
Order handheld programmer separately! C) 7ML1998-5XJ81
Multi-language Quick Start manual
Process connection
Universal flat faced flange fits ANSI/DIN/JIS This device is shipped with the Siemens Milltronics
flanges, Easy Aimer with integral (Easy Aimer ball) manual CD containing the complete ATEX Quick
2" / 50 mm A Start and instruction manual library.
3" / 80 mm B Accessories
4" / 100 mm C Metallic cable gland M20x1.5, rated -40 °C to C) 7ML1930-1AP
6" / 150 mm D +80 °C (-40 to +176 °F), HART
Antenna Metallic cable gland M20x1.5, rated -40 °C to D) 7MF4997-1AQ
2" Horn antenna, fits 50 mm or 2" nozzles1) A +80 °C (-40 to +176 °F), integrated shield for
2" Horn antenna with 100 mm extension1) B PROFIBUS PA
2" Horn antenna with 200 mm extension1) C Handheld programmer, Infrared, Intrinsically Safe 7ML1930-1BK
2" Horn antenna with 500 mm extension1) 2) D Dust cap, PTFE, for 2"/50 mm horn 7ML1930-1DE
2" Horn antenna with 1000 mm extension1) 2) E Dust cap, PTFE, for 3" /75 mm horn 7ML1930-1BL
Dust cap, PTFE, for 4"/100 mm horn 7ML1930-1BM
3" Horn antenna, fits 80 mm or 3" nozzles3) F HART modem/RS-232 (for use with a PC and 7MF4997-1DA
3" Horn antenna with 100 mm extension3) G SIMATIC PDM)
3" Horn antenna with 200 mm extension3) H HART modem/USB (for use with a PC and 7MF4997-1DB
3" Horn antenna with 500 mm extension2) 3) J SIMATIC PDM)
3" Horn antenna with 1000 mm extension2) 3) K SITRANS RD100 Remote display - see RD100 on
page 5/292
4" Horn antenna, fits 100 mm or 4" nozzles
4" Horn antenna with 100 mm extension
L
M
SITRANS RD200 Remote display - see RD200 on
page 5/294
5
4" Horn antenna with 200 mm extension N
4" Horn antenna with 500 mm extension2) P 1)
Maximum measurement range 10 m (32.8 ft)
4" Horn antenna with 1000 mm extension2) Q 2)
Available with Purge connection option 0 only
3)
Purge (Self Cleaning) Connection Maximum measurement range 20 m (65.6 ft)
4) Available with Pressure rating option 0 only
No purge connection 0
Purge connection 1 ®
HART is a registered trademark of HART Communication Foundation
Output / Communication C) Subject to export regulations AL: N, ECCN: EAR99
4 to 20 mA, HART® 0
PROFIBUS PA 1 D) Subject to export regulations AL: N, ECCN: EAR99H

Cable inlet
2 x M20x1.5 A Note 1: available with no pressure rating, 0.5 bar g maximum.
2 x ½" NPT B Please contact nacc.smpi@siemens.com for special requests.
Note: Polymeric cable glands will be provided with
M20 devices.
Approvals
General purpose, CSAUS/C, FM, Industry Canada, A
FCC, CE, R&TTE, C-TICK
CSA/FM Class II, Div. I, Groups E, F, G, Class III, B
Industry Canada, FCC, C-TICK
ATEX II 1D, 1/2D, 2D T100 ºC, CE, R&TTE, C-TICK C
Pressure rating
3 bar g (43.5 psi g) pressure maximum and +80 °C 0
(+176 °F)
0.5 bar g (7.25 psi g) maximum 1
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 102044) C12
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 27
characters) specify in plain text
Instruction manual for HART/mA device Order No.
English C) 7ML1998-5KE01
French C) 7ML1998-5KE11
German C) 7ML1998-5KE31
Note: The instruction manual should be ordered
as a separate line item on the order.
Multi-language Quick Start manual C) 7ML1998-5XH81
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.

March 2009 Siemens FI 01 · 2009 US Edition 5/197


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR260

■ Dimensional drawings

enclosure/electronics

nameplate

268 mm
(10.6")
optional purge connection with
factory-installed 1/8” NPT plug

universal slotted flange process device


tag
sensor
reference
optional point
extension
2" horn: 163 mm (6.4")
3" horn: 228 mm (9.0")
100/200/500/1000 mm 4" horn: 285 mm (11.2")
(3.93/7.87/19.68/39.37”)
horn

5
optional PTFE dust cap

49 mm
(1.9")
74.5 mm
clamp screw (2.9")
97.5 mm
(3.8")

SITRANS LR260 dimensions

■ Characteristic curves

Maximum Flange and Process Temperatures versus Allowable Ambient

90
Ambient temperature (°C)

80

70

60

50

40

30

20

10

0
0 50 100 150 200 250

Process Flange Surface Temperature (°C)

SITRANS LR250 Ambient/Process Flange Surface Temperature Curve

5/198 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR260

■ Schematics

Connect theder
Anschluss wires
Drähte
wiethe
to abgebildet:
terminals Die
as
Polaritätthe
shown: ist polarity
auf den
Klemmen
is identifiedgekenn-
on the
zeichnet.block.
terminal

Shield for
Schirm nurHART
für eigensichere
and PROFIBUS
HARTPAund
Instrinsically
Kabelverschraubung
gland PROFIBUS
Safe versionsPAonly.
Ausführungen.

Hinweise:
Notes:
1. Um die Sicherheitsanforderungen der IEC 61010-1 zu erfüllen, sind Gleichstromklemmen von einer Quelle zu versorgen, die eine galvanische Trennung zwischen Ein- und Ausgang bewirkt.
2. DC
1. Alleterminal
Feldanschlüsse
shall be müssen
suppliedentsprechend
from a sourceder angelegten
providing Eingangsspannung
electrical isoliert
isolation between sein.and output, to meet the applicable safety requirements of IEC 61010-1.
the input

5
3. All
2. Verwenden Siemust
field wiring geschirmtes Kabel mit
have insulation verdrilltem
suitable Aderpaar
for rated (14 ... 22 AWG) für die HART Ausführung.
input voltages.
4. Use
3. Eineshielded
getrenntetwisted
Leitungsverlegung
pair cable (14kann
to 22erforderlich sein, um
AWG) for HART Standardanforderungen an den Anschluss oder elektrische Richtlinien zu erfüllen.
version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
Handprogrammiergerät
Hand Programmer
SITRANS
Part number:LR250
HART
7ML1930-1BK

Artikelnummer:
7ML1930-1BK

SITRANS LR260 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/199


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

■ Overview

5
SITRANS LR300 is a 4-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, to a
range of 20 m (66 ft).

■ Benefits
• Auto False-Echo Suppression
• Infrared Intrinsically Safe handheld or remote programming
• 5.8 GHz (U.S.A. 6.3 GHz)
• Built-in diagnostics
• Various flanges, horn and waveguide antenna options avail-
able
• Extremely high signal-to-noise ratio

■ Application
The SITRANS LR300 is available both for standard applications
and for applications that require explosion proof protection.
The SITRANS LR300 features a compact design and robust con-
struction and is available with an epoxy-coated aluminum or
stainless steel enclosure. Operating at low frequency and high
signal transmission speed, it is virtually unaffected by atmo-
spheric or temperature conditions. It provides reliable measure-
ment in environments with harsh chemicals, steam, dust, en-
crustation, turbulence and agitation.
The high resistance PTFE rod antenna is chemically immune and
resistant to material buildup. The SITRANS LR300 can commu-
nicate using Modbus® or HART® protocols.
When using the flange or threaded antenna options, the SI-
TRANS LR300 is easily installed by positioning the unit on a
standpipe, bolting or threading it in place and connecting it to
the power supply. There’s no need to fill or empty the vessel for
calibration or commissioning.
• Key Applications: liquid bulk storage tanks, agitated process
vessels

5/200 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

■ Configuration

SITRANS LR300 installation

March 2009 Siemens FI 01 · 2009 US Edition 5/201


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

■ Technical specifications Process connections


• Flanged Flat faced flanges: 316L stainless
Mode of operation steel, 50, 80, 100, 150, 200 mm
Measuring principle Radar level measurement (2, 3, 4, 6, 8"), bolt hole pattern to
ASME, DIN and JIS sizes
Frequency 5.8 GHz (U.S.A. 6.3 GHz)
• Other connections Available (please see order infor-
Input mation)
Measuring range 0.4 to 20 m (1.3 to 65 ft) Power supply
Output • Universal power supply unit 48 to 230 V AC ± 15%,
Output signal 40 to 70 Hz, 28 VA (11 W)
24 to 230 V DC ± 15%, 9 W
• Analog output Optically isolated, 4 to 20 mA
Certificates and approvals
- Load Max. 450 Ω
• Safety CSANRTL/C, CE, FM, C-TICK
- Accuracy 0.02 mA
• Marine • Lloyd’s Register of Shipping
• Communications Modbus/RS-485 connection or
HART® • ABS Type Approval
Performance (reference condi- • Radio Europe, Industry Canada, FCC,
tions) C-TICK
• Error in measurement at +20 °C ±15 mm from 0.4 to 10 m • Explosion Proof • ATEX II 1/2 G EEx de IIC T6
(+68 °F) ±0.15% from 10 to 20 m • ATEX II 1/2 G EEx de [ia] IIC T6
- Temperature drift < ±0.25% of range, • CSA Class I, Div 1, Groups A, B,
-40 to +60 °C (-40 to +140 °F) C, D, E, F, G

5 - Repeatability ±2 mm, up to 3 m
• FM Class I, Div.1, Groups A, B,
C, D, E, F and G
±3 mm, from 3 m to 5 m
• Sanitary 3A Sanitary (Sanitary rod antenna
±5 mm, from 5 m to 10 m only)
±10 mm, from 10 m to 20 m Communication
- Fail-safe mA signal programmable as high, • Intrinsically Safe Siemens hand- Infrared receiver
low or hold (Loss of Echo) held programmer
Rated operating conditions - Approvals for handheld pro- IS model with ATEX EEx ia IIC T4,
Installation conditions grammer CSA/FM Class I, Div. 1, Groups A,
B, C, D
• Location Indoor/outdoor
• Programmer (remote keypad) Modbus or HART;
Ambient conditions (enclosure) upgradable Flash via RS-485
• Ambient temperature -40 to +60 °C (-40 to +140 °F) • PC SIMATIC PDM
• Installation category II • Display (local) Alphanumeric and multi-graphic
• Pollution degree 4 liquid crystal for readout and
entry
Medium conditions
• Dielectric constant εr εr > 1.6 (For εr < 3, use
waveguide antenna or stillpipe)
• Temperature -40 to +200 °C (-40 to +392 °F)
• Pressure (vessel) Dependent on process connec-
tion and temperature (refer to
Pressure/Temperature curves)
Design
• Enclosure
- Material Aluminium, epoxy coated or
optional stainless steel
- Cable inlet 2 x ½" NPT or M20x1.5
• Degree of protection Type 4X/NEMA 4X, Type 6/NEMA
6, IP67, IP68
• Weight 6.5 kg (14.3 lbs) with 2"/150 psi
flange; weight varies depending
on flange size and pressure rating
• Dielectric rod antennas
- Material PTFE
- Dimensions 41 cm (16.3") long including inte-
gral gasket (other antenna types
available)

5/202 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR300, horn antenna version C) 7 M L 5 4 1 1 - SITRANS LR300, horn antenna version C) 7 M L 5 4 1 1 -
4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7 4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna version 150 mm (6") horn with 100 mm (4") waveguide K
Stainless steel 316L with PTFE emitter 0 extension
Stainless steel 316L with PTFE emitter and purging 1 150 mm (6") horn with 150 mm (6") waveguide L
kit1) extension
Sliding waveguide system 1000 mm (40") long1) 2) 2 150 mm (6") horn with 200 mm (8") waveguide M
extension
Flange design (316L Stainless Steel)
DN 50 PN 16, Type A, flat faced1) AA 150 mm (6") horn with 250 mm (10") waveguide N
extension
DN 80 PN 16, Type A, flat faced BA
200 mm horn with 100 mm (4") waveguide exten- P
DN 100 PN 16, Type A, flat faced CA sion
DN 150 PN 16, Type A, flat faced DA 200 mm horn with 150 mm (6") waveguide exten- Q
DN 200 PN 16, Type A, flat faced EA sion
2" ASME, 150 lb1) FB 200 mm (8") horn with 200 mm (8") waveguide R
3" ASME, 150 lb, flat faced GB extension
4" ASME, 150 lb, flat faced HB 200 mm (8") horn with 250 mm (10") waveguide S
extension
6" ASME, 150 lb, flat faced JB
Waveguide only - Waveguide length 500 mm to T
8" ASME, 150 lb, flat faced1) KB 3000 mm (in 1 mm increments) (Add order code
DN 50 PN 40, flat faced1)
DN 80 PN 40, flat faced
AC
BC
Y01 and plain text: “waveguide length ...mm")
Horn with custom waveguide lengths 101 to U 5
2000 mm (Add order code Y01 and plain text:
DN 100 PN 40, flat faced CC “waveguide length...mm", and Add order code Y03
DN 150 PN 40, flat faced DC and plain text: “horn size ...mm")4)
DN 200 PN 40, flat faced EC Approvals
2" ASME, 300 lb, flat faced1) FD General Purpose, CE, CSAUS/C5) A
3" ASME, 300 lb, flat faced GD CSA Class I, Div 1, Groups A, B, C, D, E, F, G, CE5) D
4" ASME, 300 lb, flat faced HD ATEX II 1/2 G EEx de IIC T6, CE 5) E
6" ASME, 300 lb, flat faced JD FM Class I, Div 1, Groups A, B, C, D, E, F, G, FCC, F
8" ASME, 300 lb, flat faced KD 6.3 GHz, for U.S.A. only
JIS DN 50 10K1) AE General Purpose, FM, FCC, 6.3 GHz, for U.S.A. G
only
JIS DN 80 10K BE ATEX II 1/2 G EEx de [ia] IIC T6 J
JIS DN 100 10K CE
JIS DN 150 10K DE Pressure rating
Rating per Pressure/Temperature curves in manual 0
JIS DN 200 10K EE 0.5 bar g (7.25 psi g maximum) 1
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5, Further designs Order code
or EN 1092-1, or JIS B 2238 standard.)
Please add “-Z" to Order No. and specify Order
Communication/output code(s).
4 to 20 mA, HART®, Modbus 0 Acceptance test certificate: Manufacturer's test C11
Process seal/Gasket certificate M to DIN 55350, Part 18 and to ISO 9000
FKM 0 Inspection Certificate Type 3.1 per EN 10204 C12
Nitrile, only for sliding waveguide systems 1 Y15
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]:
FFKM [-35 to +200 °C (-31 to +392 °F)] 2 Measuring-point number/identification (max. 16
Enclosure/Cable inlet characters) specify in plain text
Aluminum, Epoxy painted Horn with waveguide extension custom lengths: Y01
2 x ½" NPT 0 Enter the total length of the waveguide in plain text
2 x M20x1.5 1 description (1 mm increments)
Enter the Horn size in plain text description Y03
Stainless steel 316L
2 x ½" NPT 2 [100 mm (3.94"), 150 mm (5.91"), and 200 mm
(7.87") only]
2 x M20x1.5 3
Horn size/Waveguide options
80 mm (3") horn3) B
100 mm (4") horn3) C
150 mm (6") horn D) D
200 mm (8") horn E
100 mm (4") horn with 100 mm (4") waveguide D) F
extension3)
100 mm (4") horn with 150 mm (6") waveguide D) G
extension3)
100 mm (4") horn with 200 mm (8") waveguide H
extension3)
100 mm (4") horn with 250 mm (10") waveguide J
extension3)

March 2009 Siemens FI 01 · 2009 US Edition 5/203


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

Selection and Ordering data Order No.


SITRANS LR300, horn antenna version C) 7 M L 5 4 1 1 -
4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7
tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Instruction manual
English C) 7ML1998-5CL05
French C) 7ML1998-5CL14
German C) 7ML1998-5CL34
Note: Instruction manual should be ordered as a
separate line item on the order.
Multi-language Quick Start manual C) 7ML1998-5QA85

This device is shipped with the Siemens Milltronics


manual CD containing the complete ATEX Quick
Start and instruction manual library.
Accessories
Handheld programmer for SITRANS LR300, C) 7ML5830-2AH
Intrinsically Safe, EEx ia
Enclosure wrench 7ML1830-1HB
Tag, stainless steel with hole, 7ML1930-1BJ
12 x 45 mm (0.47 x 1.77"), for fastening on
mounting-eye, one text line, (e.g. for Sensors)

5 HART® modem/RS-232 (for use with a PC and


SIMATIC PDM)
D) 7MF4997-1DA

HART modem/USB (for use with a PC and D) 7MF4997-1DB


SIMATIC PDM)
RS 485 to RS 232 converter, not isolated, C) 7ML1830-1HA
port powered
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
+80 °C (-40 to +176 °F) for General Purpose or
ATEX EEx e installations (available for HART only)
SITRANS RD100 Remote display - see RD100 on
page 5/292
SITRANS RD200 Remote display - see RD200 on
page 5/294
1) Available with pressure rating option 1 only
2)
Available with horn size option C to E only
3)
For stilling well applications only
4)
Order standard waveguide lengths 100, 150, 200, 250 mm (3.93, 5.91,
7.87, 9.84") by choosing options from Horn size/Waveguide options
5)
Includes European Radio and Industry Canada approvals, 5.8 GHz,
C-TICK
C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H

5/204 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR300, sanitary version C) 7 M L 5 4 1 2 - SITRANS LR300, sanitary version C) 7 M L 5 4 1 2 -
4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7 4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna version Instruction manual
PTFE, one piece rod antenna 0 English C) 7ML1998-5CL05
UHMW-PE, one piece rod antenna 1 French C) 7ML1998-5CL14

Process connection German C) 7ML1998-5CL34


Note: The instruction manual should be ordered
Sanitary fitting clamp A as a separate line item on the order.
Configuration/connection size Multi-language Quick Start manual C) 7ML1998-5QA85
Only for rod antenna
• 2" (50.8 mm) connection A This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
• 3" (76.2 mm) connection B Start and instruction manual library.
• 4" (101.6 mm) connection C
Accessories
Antenna extension Handheld programmer for SITRANS LR300, Intrin- C) 7ML5830-2AH
Without antenna extension 0 sically Safe, EEx ia
Mounting Clamp Tag, stainless steel with hole, 12 x 45 mm (0.47 x 7ML1930-1BJ
No mounting clamp 0 1.77"), for fastening on mounting-eye, one text line,
(e.g. for sensors)
Mounting clamp included1) 1
Sanitary fitting clamp, stainless steel:
Enclosure/cable inlet 2" (50.8 mm)
5
7ML1830-1HD
Aluminum, epoxy coated 3" (76.2 mm) 7ML1830-1HE
• 2 x ½" NPT 0 4" (101.6 mm) 7ML1830-1HF
• 2 x M20x1.5 1
Enclosure wrench 7ML1830-1HB
Stainless steel 316L HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
• 2 x ½" NPT 2 SIMATIC PDM)
• 2 x M20x1.5 3 HART modem/USB (for use with a PC and D) 7MF4997-1DB
SIMATIC PDM)
Communication/output
4 to 20 mA, HART®, Modbus A RS 485 to RS 232 converter, not isolated, port C) 7ML1830-1HA
powered
Approvals One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
General Purpose, CE, CSAUS/C2) A +80 °C (-40 to +176 °F) for General Purpose or
CSA Class I, Div I, Groups A, B, C, D, E, F, G, CE2) D) D ATEX EEx e installations (available for HART only)
ATEX II 1/2 G EEx de IIC T6, CE2) E SITRANS RD100 Remote display - see RD100 on
page 5/292
FM Class I, Div I, Groups A, B, C, D, E, F, G, FCC, D) F
6.3 GHz, for U.S.A. only SITRANS RD200 Remote display - see RD200 on
page 5/294
General Purpose, FM, FCC, 6.3 GHz, for U.S.A. D) G
only 1)
Available with pressure rating option 1 only
ATEX II 1/2 G EEx de [ia] IIC T6 J 2)
Includes European Radio and Industry Canada approvals, 5.8 GHz,
Pressure rating C-TICK
Rating per Pressure/Temperature curves in manual 0 C) Subject to export regulations AL: N, ECCN: EAR99
0.5 bar g (7.25 psi g maximum) 1 D) Subject to export regulations AL: N, ECCN: EAR99H
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12

Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15


Measuring-point number/identification (max. 16
characters) specify in plain text

March 2009 Siemens FI 01 · 2009 US Edition 5/205


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR300, rod antenna version C) 7 M L 5 4 1 3 - SITRANS LR300, rod antenna version C) 7 M L 5 4 1 3 -
4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7 4-wire, 6 GHz pulse radar level transmitter for con- 7 7 7 77 - 77 7 7
tinuous monitoring of liquids and slurries in storage tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). and pressure, to a range of 20 m (66 ft).
Antenna version Approvals
PTFE 0 General Purpose, CE, CSAUS/C6) A
Process connection CSA Class I, Div I, Groups A, B, C, D, E, F, G, CE6) D) D
Flange version (316L Stainless Steel) ATEX II 1/2 G EEx de IIC T6, CE E
DN 50 PN 16, Type A, flat faced AA
DN 80 PN 16, Type A, flat faced BA FM Class I, Div I, Groups A, B, C, D, E, F, G, FCC, D) F
6.3 GHz, for U.S.A. only
DN 100 PN 16, Type A, flat faced CA
DN 150 PN 16, Type A, flat faced DA General Purpose, FM, FCC, 6.3 GHz, for U.S.A. D) G
only
2" ASME, 150 lb, flat faced FB ATEX II 1/2 G EEx de [ia] IIC T6 J
3" ASME, 150 lb, flat faced GB
Pressure rating
4" ASME, 150 lb, flat faced HB Rating per Pressure/Temperature curves in manual 0
6" ASME, 150 lb, flat faced JB 0.5 bar g (7.25 psi g maximum) 1
DN 50 PN 40, flat faced AC Further designs Order code
DN 80 PN 40, flat faced BC
Please add “-Z" to Order No. and specify Order
DN 100 PN 40, flat faced CC code(s).
DN 150 PN 40, flat faced DC Acceptance test certificate: Manufacturer's test C11
2" ASME 300 lb, flat faced1) FD certificate M to DIN 55350, Part 18 and to ISO 9000

5 3" ASME, 300 lb, flat faced GD Inspection Certificate Type 3.1 per EN 10204 C12
4" ASME, 300 lb,flat faced HD Inactive custom shield lengths: Enter the total Y01
6" ASME, 300 lb, flat faced JD length of the inactive shield in plain text description
(in 1 mm increments).
JIS DN 50 10K AE Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
JIS DN 80 10K BE Measuring-point number/identification (max. 16
JIS DN 100 10K CE characters) specify in plain text
JIS DN 150 10K DE Instruction manual Order No.
(Note: Flange bolting patterns and facings dimen- English C) 7ML1998-5CL05
sionally correspond to the applicable ASME B16.5, French C) 7ML1998-5CL14
or EN 1092-1, or JIS B 2238 standard.) German C) 7ML1998-5CL34
Threaded version (316L Stainless Steel) Note: Instruction manual should be ordered as a
1½" NPT [(Taper), ANSI/ASME B1.20.1] LA separate line item on the order.
2" NPT [(Taper), ANSI/ASME B1.20.1] MA Multi-language Quick Start manual C) 7ML1998-5QA85
R 1½" [(BSPT), EN 10226] LC This device is shipped with the Siemens Milltronics
R 2" [(BSPT), EN 10226] MC manual CD containing the complete ATEX Quick
G 1½" [(BSPP), EN ISO 228-1] LE Start and instruction manual library.
G 2" [(BSPP), EN ISO 228-1] ME Accessories
Antenna extension, or inactive shield length Handheld programmer for SITRANS LR300, Intrin- C) 7ML5830-2AH
Without antenna extension 0 sically Safe, EEx ia
PTFE extension Antenna rod, PTFE 7ML1830-1HC
50 mm (1.97") 1 Antenna extension, 50 mm (2"), PTFE 7ML1830-1CH
100 mm (3.94") 2 Antenna extension, 100 mm (4"), PTFE 7ML1830-1CG
Stainless steel 316L extension Tag, stainless steel with hole, 7ML1930-1BJ
100 mm (3.94")2) 3 12 x 45 mm (0.47 x 1.77"), for fastening on mount-
150 mm (5.91")2) 4 ing-eye, one text line, (e.g. for sensors)
Enclosure wrench 7ML1830-1HB
200 mm (7.87")2) 5
250 mm (9.84")2) 6 HART® modem/RS-232 (for use with a PC and D) 7MF4997-1DA
SIMATIC PDM)
Custom inactive shield length 101 mm to 1000 mm 7
HART modem/USB (for use with a PC and D) 7MF4997-1DB
(in 1 mm increments) Add order code Y01 and
SIMATIC PDM)
plain text: “Inactive shield length...mm"2)
RS 485 to RS 232 converter, not isolated, port C) 7ML1830-1HA
Process Seal/Gasket powered
Integral Gasket3) 4) 0
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
FKM O-ring5) 1 +80 °C (-40 to +176 °F) for General Purpose or
Enclosure/Cable inlet ATEX EEx e installations (available for HART only)
Aluminum, Epoxy painted SITRANS RD100 Remote display - see RD100 on
2 x ½" NPT 0 page 5/292
2 x M20x1.5 1 SITRANS RD200 Remote display - see RD200 on
page 5/294
316L Stainless steel
2 x ½" NPT 2 1)
For use with pressure rating option 1 only
2 x M20x1.5 3 2)
For use with all process connection options except AA, FB, AC, FD, AE, LA,
Communication/output LC and LE
3)
4 to 20 mA, HART®, Modbus A Available with flat faced flange process connections only
4)
Available with antenna extension options 0 to 2 only
5)
Not available for combination of flat faced flanges with antenna extension
options 0 to 2
6)
Includes European Radio and Industry Canada approvals, 5.8 GHz,
C-TICK
C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H

5/206 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

■ Characteristic curves

5
SITRANS LR300 Process Pressure/Temperature derating curves

■ Schematics

SITRANS LR300 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/207


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR300

■ Dimensional drawings

SITRANS LR300 dimensions

5/208 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200 and SITRANS LR300 Antennas

■ Integration

Antenna configurations for SITRANS LR200 and LR300

■ Technical specifications
Antenna Types Flat Faced Flange Shielded Rod Sanitary Rod Horn (4", 6", 8" sizes Waveguide
with Rod (1 piece construction) available)
Connection type Flat faced flange Threaded 2" NPT, R 2" Sanitary fitting clamp Flat faced flange Flat faced flange
nominal pipe sizes 50, (BSPT), G 2" (BSPP) or 50, 80, 100 mm (2, 3, nominal pipe sizes 50, nominal pipe sizes 50,
80, 100, 150 mm (2, 3, flat faced flange 4") sizes 80, 100, 150 mm (2, 3, 80, 100, 150 mm (2, 3,
4, 6") nominal pipe sizes 80, 4, 6") 4, 6")
100 mm (3, 4")
Wetted parts PTFE PTFE, 316L stainless UHME-PE or PTFE 316L stainless steel 316L stainless steel
steel, FKM o-ring PTFE, FKM o-ring PTFE, FKM o-ring
Extensions 50 or 100 mm (2 or 4") 100, 150, 200 or N/A use waveguide for two sections (max.)
PTFE or UHMW-PE 250 mm (4, 6, 8 or 10") extensions to 6 m can be connected
standard shield length (20 ft) long together
Max. overall length:
3 m (9.8 ft)
Dielectric constant >3 >3 >3 >3 > 1.6
Insertion length 41 cm (16.3") variable 41 cm (16.3") variable with extension variable
(max.)
Purging option (liq- No No No Yes Yes
uid or gas)
Sliding waveguide Yes No No Yes N/A
option for digesters1)
Weight2) 6.5 kg (14.3 lbs) 5.0 kg (11 lbs) 5.0 kg (11 lbs) 7.5 kg (16.5 lbs) 8.0 kg (17.6 lbs)
1 m (39") length
Approvals 3) 3) 3A 3) 3)

1)
Maximum pressure 0.5 bar g at +60 °C (7.25 psi g at +140 °F)
2)
Not including extensions, includes SITRANS LR200 or SITRANS LR300 and
smallest process connection
3)
Please see a Siemens representative for a list of safety and radio approvals.

March 2009 Siemens FI 01 · 2009 US Edition 5/209


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200 and SITRANS LR300 Antennas

■ Selection and Ordering Data


SITRANS LR200 and SITRANS LR300 Specials
SITRANS LR300 Aluminum Enclosure Kit with SITRANS LR2 00 aluminum enclosure with board C) PBD-51036538
Electronics and Covers (7ML5411, 7ML5412, stack, 6.3 GHz, NPT cable inlet, approval option
7ML5413), calibrated for use with standard C, with PROFIBUS PA communication, no pro-
rod antenna cess connection. See note 7.
SITRANS LR200 aluminum enclosure with board C) PBD-51036539
stack, 5.8 GHz, NPT cable inlet, approval option
E, with PROFIBUS PA communication, no pro-
cess connection. See note 7.
SITRANS LR300 aluminum enclosure with board C) PBD-51035860
stack, M20 cable inlet, approval option A, with SITRANS LR200/LR300 Horn Antenna Kits
HART® communication, no process connection. with mounting screws (no emitter supplied)
See note 7.
SITRANS LR300 aluminum enclosure with board PBD-51035377
stack, M20 cable inlet, approval option E, with
HART communication, no process connection.
See note 7.
SITRANS LR300 aluminum enclosure with board C) PBD-51035336 80 mm (3") horn antenna kit PBD-25500K02A
stack, M20 cable inlet, approval option G, with 100 mm (4") horn antenna kit PBD-25500K03A
HART communication, no process connection.
See note 7. 150 mm (6") horn antenna kit PBD-25500K05A
SITRANS LR300 aluminum enclosure with board C) PBD-51035566 200 mm (8") horn antenna kit PBD-25500K07A
stack, M20 cable inlet, approval option J, with
SITRANS LR300 Horn Antenna Extension Kits
5 HART communication, no process connection.
See note 7.
with mounting screws

SITRANS LR200 Aluminum Enclosure Kit with


Electronics and Covers (7ML5422, 7ML5423, 100 mm (4") horn antenna extension kit PBD-
7ML5424, 7ML5425), calibrated for use with 25501K0100A
standard rod antenna 150 mm (6") horn antenna extension kit PBD-
25501K0150A
200 mm (8") horn antenna extension kit PBD-
25501K0200A
SITRANS LR200 aluminum enclosure with board C) PBD-51036169
stack, 5.8 GHz, M20 cable inlet, approval option 250 mm (10") horn antenna extension kit PBD-
A, with HART communication, no process con- 25501K0250A
nection. See note 7. 500 mm (20") horn antenna extension kit PBD-
SITRANS LR200 aluminum enclosure with board C) PBD-51036236 25501K0500A
stack, 5.8 GHz, M20 cable inlet, approval option 1000 mm (40") horn antenna extension kit PBD-
E, with HART communication, no process con- 25501K1000A
nection. See note 7.
SITRANS LR200/LR300 Flanged Rod Antenna
SITRANS LR200 aluminum enclosure with board C) PBD-51036530 Kit with 316L SS flat faced flanges
stack, 6.3 GHz, M20 cable inlet, approval option
C, with HART communication, no process con-
nection. See note 7.
SITRANS LR200 aluminum enclosure with board C) PBD-51036531
stack, 5.8 GHz, M20 cable inlet, approval option
E, with PROFIBUS PA communication, no pro-
cess connection. See note 7. Flanged PTFE rod antenna kit, 2" ASME, 150 lb. PBD-
See drawing 51003 on 51003K020AAAA
SITRANS LR200 aluminum enclosure with board C) PBD-51036532 http://www.siemens.com/radar.
stack, 5.8 GHz, M20 cable inlet, approval option See notes 1 and 6.
A, with PROFIBUS PA communication, no pro-
cess connection. See note 7. Flanged PTFE rod antenna kit, 2" ASME, 150 lb. PBD-
See drawing 51003 on 51003K050AJAA
SITRANS LR200 aluminum enclosure with board C) PBD-51036533 http://www.siemens.com/radar.
stack, 6.3 GHz, M20 cable inlet, approval option See notes 1 and 6.
C, with PROFIBUS PA communication, no pro-
cess connection. See note 7. Flanged PTFE rod antenna kit, JIS 10K DN 50. PBD-
See drawing 51003 on 51003K050AOAA
SITRANS LR200 aluminum enclosure with board C) PBD-51036534 http://www.siemens.com/radar.
stack, 5.8 GHz, NPT cable inlet, approval option See notes 1 and 6.
A, with HART communication, no process con-
nection. See note 7.
SITRANS LR200 aluminum enclosure with board C) PBD-51036535
stack, 6.3 GHz, NPT cable inlet, approval option
C, with HART communication, no process con-
nection. See note 7.
SITRANS LR200 aluminum enclosure with board C) PBD-51036536
stack, 5.8 GHz, NPT cable inlet, approval option
E, with HART communication, no process con-
nection. See note 7.
SITRANS LR200 aluminum enclosure with board C) PBD-51036537
stack, 5.8 GHz, NPT cable inlet, approval option
E, with HART communication, no process con-
nection. See note 7.

5/210 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200 and SITRANS LR300 Antennas
SITRANS LR200/LR300 PTFE Rod Antenna Kit SITRANS LR200/LR300 Horn Antenna Kit with
with 316L SS 1½" pipe thread process con- 316L SS flat faced flange, with PTFE emitter
nection (without waveguide)

PTFE rod antenna kit, 1½" NPT 316L SS Process PBD- Horn antenna kit, 2" ASME 316L SS flange 3" PBD-
Connection, FKM O-ring; See drawing 51004 51004K1AAA horn, PTFE emitter; See notes 1 and 6. 51006K020AAAA
on
http://www.siemens.com/radar. See note 6. Horn antenna kit, 2" ASME 316L SS flange 4" PBD-
horn, PTFE emitter; See notes 1 and 2. 51006K020AABA
PTFE rod antenna kit, R 1½" (BSPT), EN 10226 PBD-
316L SS Process Connection, FKM O-ring; See 51004K2AAA Horn antenna kit, 2" ASME 316L SS flange 6" PBD-
drawing 51004 on horn, PTFE emitter; See notes 1 and 2. 51006K020AACA
http://www.siemens.com/radar. See note 6. Horn antenna kit, 2" ASME 316L SS flange 8" PBD-
PTFE rod antenna kit, 1½" G 316L SS Process PBD- horn, PTFE emitter; See notes 1 and 2. 51006K020AADA
Connection, FKM O-ring; See drawing 51004 on 51004K3AAA Horn antenna kit, DN 50 PN 16 316L SS flange PBD-
http://www.siemens.com/radar. See note 6. 80 mm horn, PTFE emitter; See notes 1 and 2. 51006K050AJAA
SITRANS LR200/LR300 PTFE Rod Antenna Kit Horn antenna kit, DN 50 PN 16 316L SS flange PBD-
with 316L SS 2" pipe thread process connec- 100 mm horn, PTFE emitter; See notes 1 and 2. 51006K050AJBA
tion
Horn antenna kit, DN 50 PN 16 316L SS flange PBD-
150 mm horn, PTFE emitter; See notes 1 and 2. 51006K050AJCA
Horn antenna kit, DN 50 PN 16 316L SS flange PBD-
200 mm horn, PTFE emitter; See notes 1 and 2. 51006K050AJDA
PTFE rod antenna kit, 2" NPT 316L SS Process
Connection, FKM O-ring; See drawing 51005 on
PBD-
51005K1AAA
SITRANS LR200/LR300 Sanitary Rod Antenna
with Sanitary Fitting Clamp Flange mounting
5
http://www.siemens.com/radar. See note 6. and bushing.
PTFE rod antenna kit, R 2" (BSPT), EN 10226 PBD- See drawing 51010 on
316L SS Process Connection, FKM O-ring; See 51005K2AAA http://www.siemens.com/radar
drawing 51005 on (Sanitary Fitting Clamps not included)
http://www.siemens.com/radar. See note 6.
PTFE rod antenna kit, 2" G 316L SS Process Con- PBD- PTFE sanitary rod antenna kit, 2" mounting con- PBD-51010K1AA
nection, FKM O-ring; See drawing 51005 on 51005K3AAA nection. See note 6.
http://www.siemens.com/radar. See note 6.
PTFE sanitary rod antenna kit, 3" mounting con- PBD-51010K2AA
SITRANS LR200/LR300 PTFE Rod Antenna Kit nection. See note 6.
(100 mm shield) with 316L SS 2" pipe thread
process connection PTFE sanitary rod antenna kit, 4" mounting con- PBD-51010K3AA
nection. See note 6.
UHMW-PE sanitary rod antenna kit, 2" mounting PBD-51010K1AB
connection. See note 6.
UHMW-PE sanitary rod antenna kit, 3" mounting PBD-51010K2AB
PTFE rod antenna shielded kit, 2" NPT 316L SS PBD- connection. See note 6.
Process Connection, FKM O-ring, 100 mm 316L 51002K0100AAA UHMW-PE sanitary rod antenna kit, 4" mounting PBD-51010K3AB
SS shield. See drawing 51002 on connection). See note 6.
http://www.siemens.com/radar.
See notes 3 and 6. SITRANS LR200/LR300 PTFE Flanged Rod
Antenna Kit with 316L SS shield and 316L SS
PTFE rod antenna shielded kit, R 2" (BSPT), EN PBD- flat faced flange
10226 316L SS Process Connection, FKM O- 51002K0100BAA
ring, 100 mm
316L SS shield. See drawing 51002 on
http://www.siemens.com/radar.
See notes 3 and 6.
PTFE rod antenna shielded kit, 2" G 316L SS PBD- PTFE shielded rod antenna kit, flanged, 3" ASME PBD-
Process Connection, FKM O-ring, 51002K0100CAA 150 lb 316L SS flange, 100 mm 316L SS shield. 51014K0100AAA
100 mm 316L SS shield. See drawing 51002 on See notes 1 and 6.
http://www.siemens.com/radar. PTFE shielded rod antenna kit, flanged, DN 80 PBD-
See notes 3 and 6. PN 16 316L SS flange, 100 mm 316L SS shield. 51014K0100EJA
See notes 1 and 6.
PTFE shielded rod antenna kit, flanged, 3" ASME PBD-
150 lb 316L SS flange, 150 mm 316L SS shield. 51014K0150AAA
See notes 1 and 6.
PTFE shielded rod antenna kit, flanged, DN 80 PBD-
PN 16 316L SS flange, 150 mm 316L SS shield. 51014K0150EJA
See notes 1 and 6.
PTFE shielded rod antenna kit, flanged, 3" ASME PBD-
150 lb 316L SS flange, 200 mm 316L SS shield. 51014K0200AAA
See notes 1 and 6.
PTFE shielded rod antenna kit, flanged, DN 80 PBD-
PN 16 316L SS flange, 200 mm 316L SS shield. 51014K0200EJA
See notes 1 and 6.

March 2009 Siemens FI 01 · 2009 US Edition 5/211


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200 and SITRANS LR300 Antennas
PTFE shielded rod antenna kit, flanged, 3" ASME PBD-
150 lb 316L SS flange, 250 mm 316L SS shield. 51014K0250AAA
See notes 1 and 6.
PTFE shielded rod antenna kit, flanged, DN 80 PBD-
PN 16 316L SS flange, 250 mm 316L SS shield. 51014K0250EJA
See notes 1 and 6.
PTFE paste
Kit, PTFE paste, Tube, 250 mL. See note 7. C) PBD-51036065

Cable gland
One polymeric cable gland M20x1.5, rated 7ML1930-1AN
-20 to +80 °C (-4 to +176 °F) for General Pur-
pose and ATEX EEx e
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
+80 °C (-40 to +176 °F) for General Purpose or
ATEX EEx e installations (available for HART
only)
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
+80 °C (-40 to +176 °F) with integrated shield
connection (available for PROFIBUS PA)
C) Subject to export regulations AL: N, ECCN: EAR99
Note 1: Available in flange sizes including ASME, DIN and JIS:
please contact nacc.smpi@siemens.com.

5 Note 2: Available with no pressure rating


Note 3: Available in other shield lengths: please contact
nacc.smpi@siemens.com.
Note 4: Available with no pressure rating and with General Pur-
pose Approvals only
Note 5: Please contact nacc.smpi@siemens.com for pricing and
part number. Submit completed Application Questionnaire
found on page 5/172
Note 6: Available with Pressure rating; serial number of original
unit required with completed Application Questionnaire found on
page 5/172
Note 7: Subject to export regulations AL: N, ECCN: EAR99

5/212 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR200 and SITRANS LR300 Antennas

■ Characteristic curves

SITRANS LR200/LR300 Process Pressure/Temperature derating curves

March 2009 Siemens FI 01 · 2009 US Edition 5/213


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR400

■ Overview ■ Application
It provides excellent results on low dielectric media.
SITRANS LR400 is available for standard applications and for
applications that require explosion proof protection.
SITRANS LR400 features robust enclosure, flange and horn
components. It is virtually unaffected by atmospheric or temper-
ature conditions within the vessel.
Safe on-site local programming is simple using the Intrinsically
Safe handheld programmer. SIMATIC PDM can be used for easy
remote programming.
The characteristics of 24 GHz and high signal-to-noise ratio con-
tribute to exceptional signal reflection, regardless of the dielec-
tric value of the medium.
• Key applications: long-range liquid or slurry applications, high
temperature or high pressure, low dielectric media, such as
LPG (liquid, petroleum, gas)

The SITRANS LR400 is a 4-wire, 24 GHz FMCW radar level trans-


mitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature and high pres-
sure, to a range of 50 m (164 ft); ideal for low dielectric media.
5
■ Benefits
• Easy installation and commissioning, low maintenance
• Self-calibration with internal reference
• Built-in diagnostics
• Auto False-Echo Suppression and advanced echo processing
• 24 GHz and high signal-to-noise ratio
• Communication using HART® or PROFIBUS PA
• Programming using infrared Intrinsically Safe handheld pro-
grammer or with SIMATIC PDM or HART handheld device

■ Configuration

SITRANS LR400 installation

5/214 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR400

■ Technical specifications Programming


Intrinsically Safe Siemens handheld Infrared receiver
Mode of operation programmer
Measuring principle FMCW radar level measurement (ordered separately)
Frequency 24 to 25 GHz FMCW • Approvals for handheld program- IS model with ATEX EEx ia IIC T4,
mer CSA/FM Class I, Div. 1, Groups A,
Measuring range 0.35 to 50 m (1.15 to 164 ft) B, C, D T6 @ max. ambient tem-
Output perature of +40 °C (+104 °F)

Analog output (HART®) Handheld communicator HART communicator 375

• Signal range Optically isolated 4 to 20 mA PC SIMATIC PDM

• Load Max. 600 Ω Display (local) Alphanumeric LCD for readout


(330 Ω for [ia] versions, Area and entry
classification options G, L, P, S) Power supply 100 to 230 V AC ± 15%
• Relay NC or NO function, max. DC 50 V, (50/60 Hz), 6 W (12 VA)
max. 200 mA, rating 5 W or
Communication HART, optional PROFIBUS PA 24 V DC +25/-20%, 6 W (optional)
PROFIBUS PA protocol Layer 1 and 2, Class A, Profile 3.0 Certificates and approvals
Performance (Reference conditions) • Safety CSAUS/C, CE, FM, C-TICK
• Dead band 0 to 350 mm from bottom edge of • Shipping • Lloyd’s Register of Shipping
flange • ABS
• Error in measurement at +25 °C ≤ 5 mm from 2 to 10 m • Radio Europe (R&TTE, CETECOM),
(+77 °F)

- Repeatability
≤ 15 mm from 10 to 50 m
≤ 1 mm • Hazardous areas
Industry Canada, FCC, C-TICK
ATEX II 1/2 G EEx dem [ia] IIC T6
5
ATEX II 1/2 G EEx dem IIC T6
- Fail-safe mA signal programmable as high, CSA/FM Class I, Div. 1, Groups B,
low or hold (LOE) C, D; Class II, Div. 1, Groups E, F,
Rated operating conditions G; Class III T6, INMETRO

• Amb. temperature for enclosure -40 to +65 °C (-40 to +149 °F) Optional equipment Purging (self-cleaning) system
PTFE dust cover
• Location Indoor/outdoor
• Installation category II
• Pollution degree 4
Medium conditions
Dielectric constant εr>1.4
Process temperature range
• Standard -40 to +200 °C (-40 to +392 °F)
-20 to +200 °C (-4 to +392 °F) for
SITRANS LR400 with ATEX rating
• With optional temperature exten- -40 to +250 °C (-40 to +482 °F)
sion
Vessel Pressure Up to 40 bar g (process connec-
tion dependent)
Design
Weight Approx. 12.2 kg (26.8 lbs) with 3"
150 psi flange
Materials
• Enclosure Die-cast aluminum, painted
• Degree of protection IP67/Type 4X/NEMA 4X, Type
6/NEMA 6
• Cable inlet 2x M20x1.5 or ½" NPT
Process connections
• Flat-faced flanges 316L stainless steel, 80, 100,
150 mm, bolt holes matching
EN 1092-1 and JIS B 2238
• Raised face flanges 316L stainless steel, 3", 4", 6", bolt
holes matching ASME B 16.5

March 2009 Siemens FI 01 · 2009 US Edition 5/215


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR400

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR400 C) 7 M L 5 4 2 1 - SITRANS LR400 C) 7 M L 5 4 2 1 -
4-wire, 24 GHz FMCW radar level transmitter for 7 7 7 77 - 77 7 7 4-wire, 24 GHz FMCW radar level transmitter for 7 7 7 77 - 77 7 7
continuous monitoring of liquids and slurries in stor- continuous monitoring of liquids and slurries in stor-
age and process vessels including high tempera- age and process vessels including high tempera-
ture and high pressure, to a range of 50 m (164 ft); ture and high pressure, to a range of 50 m (164 ft);
ideal for low dielectric media. ideal for low dielectric media.
Order handheld programmer separately! Order handheld programmer separately!
Process temperature range ATEX II 1/2 GD EEx dem [ia] IIC T6; CE, R&TTE 3) 4) L
-40 °C to +200 °C (-40 to +392 °F), standard 0 ATEX II 2G EEx d IIC T6; CE, CETECOM3) M
-40 °C to +250 °C (-40 to +482 °F), high tempera- 1 ATEX II 2G EEx dem IIC T6; CE, CETECOM3) N
ture extension
ATEX II 2G EEx dem [ia] IIC T6; CE, P
Process connection CETECOM3) 4)
Universal flange 3"/80 mm1) A ATEX II 1/2 GD EEx d IIC T6; CE, CETECOM2) 3) Q
Universal flange 4"/100 mm1) B ATEX II 1/2 GD EEx dem IIC T6; CE, R
Universal flange 6"/150 mm1) D CETECOM2) 3)
DN 80, PN 16, Type A, flat faced S ATEX II 1/2 GD EEx dem [ia] IIC T6; CE, S
DN 80, PN 40, Type B1, raised face C CETECOM2) 3) 4)
DN 100, PN 16, Type A, flat faced T FM Class I, Div. 1, Groups B, C, D; Class II/III, D) T
Div. 1, Groups E, F, G; FCC2)
DN 100, PN 40, Type B1, raised face G CSA Class I, Div. 1, Groups B, C, D; Class II/III, U
D)
DN 150, PN 16, Type A, flat faced U Div. 1, Groups E, F, G; FCC2)
3" ASME, 150 lb, raised face E
Local operation

5
3" ASME, 300 lb, raised face F Local Display Only. Handheld programmer not 2
4" ASME, 150 lb, raised face J included (Order programmer separately.)
4" ASME, 300 lb, raised face K Further designs Order code
6" ASME, 150 lb, raised face N Please add “-Z" to Order No. and specify Order code(s).
JIS, DN 80 10K Q Manufacturer’s test certificate M to DIN 55350, C11
JIS, DN 100 10K R Part 18 and to ISO 9000
JIS, DN 150 10K V Inspection Certificate Type 3.1 per EN 10204 C12
(Note: Flange bolting patterns and facings dimen- Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
sionally correspond to the applicable ASME B16.5, Measuring-point number/identification (max. 16
or EN 1092-1, or JIS B 2238 standard.) characters); specify in plain text
Antenna Instruction manual Order No.
Horn antenna, long 93 mm (3.66") diam. for D English C) 7ML1998-5FH06
100 mm (4") nozzles German C) 7ML1998-5FH36
Horn antenna, short 74 mm (2.91") diam. for 80 mm K French C) 7ML1998-5FH15
(3") nozzles Multi-language Quick start manual C) 7ML1998-5QN83
Antenna purging system This device is shipped with the Siemens Milltronics
None 0 manual CD containing the complete ATEX Quick
Purging system 1 Start and instruction manual library.
Note: Available with process connections A, B or D, Accessories
only, and available for Area Classifications A or B Handheld programmer Intrinsically Safe, EEx ia C) 7ML5830-2AJ
only
Long horn dust cover, PTFE 7ML1930-1AH
Process seal/gasket Short horn dust cover, PTFE 7ML1930-1AJ
PTFE for -40 to +250 °C (-40 to +482 °F) flange 1 D) 7MF4997-1DA
HART modem/RS-232 (for use with a PC and
temperatures
SIMATIC PDM)
FKM for -20 to +200 °C (-4 to +392 °F) flange tem- 3
HART modem/USB (for use with a PC and D) 7MF4997-1DB
peratures2)
SIMATIC PDM)
Output/communication One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP
4 to 20 mA, HART 0 +80 °C (-40 to +176 °F) for General Purpose or
PROFIBUS PA 1 ATEX EEx e installations (available for HART only)
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
Power supply/cable inlet +80 °C (-40 to +176 °F) with integrated shield con-
100 to 230 V AC nection (available for PROFIBUS PA)
• 2 x M20x1.5 B SITRANS RD100 Remote display - see RD100 on
• 2 x ½“ NPT C page 5/292
24 V DC SITRANS RD200 Remote display - see RD200 on
page 5/294
• 2 x M20x1.5 E
• 2 x ½“ NPT F 1) Available with antenna purging system option 1 only, universal, 0.5 bar g
(7.25 psi g) maximum
Area classification 2) Available with process temperature range option 0 only
General Purpose, CE, CETECOM3) A 3)
Germany and Belgium end customers only
General Purpose, CSAUS/C, Industry Canada, FCC, B 4)
Available only with power supply option E or F
CE and R&TTE
ATEX II 2G EEx d IIC T6; CE, R&TTE E C) Subject to export regulations AL: N, ECCN: EAR99
D) Subject to export regulations AL: N, ECCN: EAR99H
ATEX II 2G EEx dem IIC T6; CE, R&TTE F
ATEX II 2G EEx dem [ia] IIC T6; CE, R&TTE4) G
ATEX II 1/2 GD EEx d IIC T6; CE, R&TTE3) J
ATEX II 1/2 GD EEx dem IIC T6; CE, R&TTE2) K

5/216 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR400

■ Selection and Ordering Data


SITRANS LR400 Spare parts
3"/80 mm Universal Flange, PBD- SITRANS LR400 Aluminum C) PBD-
without horn or hub. 51035813 enclosure with AC power, M20 51035872
See note 1. cable inlet, HART® communi-
cation and ATEX II 1/2 GD EEx
4"/100 mm Universal Flange, PBD- d IIC T6, CE and R&TTE
without horn or hub. 51035814 approvals. See note 2.
See note 1.
SITRANS LR400 Aluminum C) PBD-
6"/150 mm Universal Flange, PBD- enclosure with AC power, M20 51035873
without horn or hub. 51035815 cable inlet, PROFIBUS PA
See note 1. communication and ATEX II
8"/200 mm Universal Flange, PBD- 1/2 GD EEx d IIC T6, CE and
without horn or hub. 51035816 R&TTE approvals. See note 2.
See note 1. SITRANS LR400 Aluminum C) PBD-
Purging kit with Easy Aimer PBD- enclosure with DC power, M20 51036481
ball, no flange, no horn. 51036110 cable inlet, HART communica-
See note 1. tion and and GP, CE and CET-
ECOM approvals.
Purging kit with Easy Aimer PBD- See note 2.
ball with 4"/100 mm flange, no 51035810
horn. See note 1. SITRANS LR400 Aluminum C) PBD-
enclosure with DC power, M20 51036482
Purging kit with Easy Aimer PBD- cable inlet, PROFIBUS PA
ball with 6"/150 mm flange, no 51035811 communication and GP, CE
horn. See note 1. and CETECOM approvals.
Purging Kit with Easy Aimer PBD-
See note 2. 5
ball with 8"/200 mm flange, no 51035812 SITRANS LR400 Aluminum C) PBD-
horn. See note 1. enclosure with DC power, M20 51036483
cable inlet, HART communica-
Short horn antenna, no emitter PBD- tion and GP, CE, CSA, Industry
supplied 22475K1A Canada, FCC and R&TTE.
Long horn antenna, no emitter PBD- See note 2.
supplied 22475K2A SITRANS LR400 Aluminum C) PBD-
Short horn antenna, purged, PBD- enclosure with DC power, M20 51036484
no emitter supplied 22475K3A cable inlet, PROFIBUS PA
communication and GP, CE,
Long horn antenna, purged, PBD- CSA, Industry Canada, FCC
no emitter supplied 22475K4A and R&TTE. See note 2.
Replacement display module, PBD- SITRANS LR400 Aluminum C) PBD-
SITRANS LR400 Liquids and 51035410 enclosure with DC power, M20 51036485
Solids versions cable inlet, HART communica-
4" Horn antenna extension kit PBD- tion and ATEX II 1/2 GD EEx d
with General Purpose approv- 51035474 IIC T6, CE and R&TTE approv-
als als. See note 2.

8" Horn antenna extension kit PBD- SITRANS LR400 Aluminum C) PBD-
with General Purpose approv- 51035473 enclosure with DC power, M20 51036486
als cable inlet, PROFIBUS PA
communication and ATEX II
8" Horn antenna extension kit PBD- 1/2 GD EEx d IIC T6, CE and
for hazardous units 51036180 R&TTE approvals. See note 2.
SITRANS LR400 Aluminum C) PBD-
Note 1: Available with no pressure rating and with General Pur-
enclosure with AC power, M20 51036479
cable inlet, HART® communi- pose approvals only
cation, and GP, CE, and CETE- Note 2: Subject to export regulations AL: N, ECCN: EAR99
COM approvals.
See note 2. Please contact nacc.smpi@siemens.com for special requests.
SITRANS LR400 Aluminum C) PBD- C) Subject to export regulations AL: N, ECCN: EAR99
enclosure with AC power, M20 51036480
cable inlet, PROFIBUS PA
communication and GP, CE,
and CETECOM approvals.
See note 2.
SITRANS LR400 Aluminum C) PBD-
enclosure with AC power, M20 51035867
cable inlet, HART communica-
tion and GP, CE, CSA, Industry
Canada, FCC and R&TTE.
See note 2.
SITRANS LR400 Aluminum C) PBD-
enclosure with AC power, M20 51035871
cable inlet, PROFIBUS PA
communication and GP, CE,
CSA, Industry Canada, FCC
and R&TTE. See note 2.

March 2009 Siemens FI 01 · 2009 US Edition 5/217


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR400

■ Characteristic curves

SITRANS LR400 Process Pressure/Temperature derating curves

5/218 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR400

■ Dimensional drawings

SITRANS LR400 dimensions

March 2009 Siemens FI 01 · 2009 US Edition 5/219


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR400

■ Schematics

SITRANS LR400 connections

5/220 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR460

■ Overview ■ Application
SITRANS LR460 provides excellent results even during condi-
tions of extreme dust. The integral Easy Aimer included on the
SITRANS LR460 allows for easy positioning for optimum mea-
surement on solids.
Process Intelligence onboard SITRANS LR460 means advanced
signal processing is harnessed for reliable operation on both
simple and difficult solids application.
SITRANS LR460 features a robust enclosure, flange and horn
components. It is virtually unaffected by atmospheric or temper-
ature conditions within the vessel.
An optional dust cap is available for sticky solids. Optional air
purging is also available for extremely sticky applications.
Safe on-site local programming is simple using the Intrinsically
Safe handheld programmer. SIMATIC PDM can be used for easy
remote programming using HART or PROFIBUS PA.
The characteristics of 24 GHz and high signal-to-noise ratio con-
tribute to exceptional signal reflection, regardless of the dielec-
The SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level trans- tric value of the medium.
mitter with extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of solids up to • Key applications: long-range dusty applications, cement pow-
100 m (328 ft). It is ideal for measurement in extreme dust. der, fly-ash, coal, flour, grain, plastics
5
■ Benefits
• Process Intelligence for advanced signal processing and
quick and easy adjustment
• Self-guided quick start wizard for plug and play start-up
• 24 GHz provides superior reflective properties on solids sur-
faces
• 100 m (328 ft) range for long-range and difficult applications
• Easy Aimer optimizes signal quality on sloped surfaces
• Programming using infrared Intrinsically Safe handheld pro-
grammer or with SIMATIC PDM or HART® handheld device

■ Configuration

SITRANS LR460 installation

March 2009 Siemens FI 01 · 2009 US Edition 5/221


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR460

■ Technical specifications Power supply 100 to 230 V AC ± 15%


(50/60 Hz), 6 W (12 VA)
Mode of operation or
Measuring principle FMCW radar level measurement 24 V DC +25/-20%, 6 W (optional)

Frequency 24.2 to 25.2 GHz FMCW Certificates and approvals

Measuring range 0.35 to 100 m (1.15 to 328.08 ft) • General CSAUS/C, CE, FM, C-TICK

Output • Radio European Radio (R&TTE), Indus-


try Canada, FCC, C-TICK
®
Analog output (HART )
• Hazardous Areas CSA/FM Class II, Div. 1, Groups
• Signal range Optically isolated 4 to 20 mA E, F and G, Class III
• Load Max. 600 Ω ATEX II 1D, 1/2 D, 2D T85 °C
• Fail-safe mA signal programmable as high, Optional equipment
low or hold (LOE) Dust cap PTFE
Communication HART, optional PROFIBUS PA Air purge connection 1/8" NPT
Digital output Relay, NC or NO function, max.
50 V DC, max. 200 mA, rating 5 W
PROFIBUS PA protocol Layer 1 and 2, Class A, Profile
3.01
Performance (Reference conditions according to IEC 60770-1)
• Non-linearity Greater of 25 mm (1") or 0.25% of
span (including hysteresis and

5 non-repeatability), over the full


ambient temperature range
• Non-repeatability ≤10 mm (0.4")
Rated operating conditions
• Amb. temperature for enclosure -40 to +65 °C (-40 to +149 °F)
• Location Indoor/outdoor
• Installation category II
• Pollution degree 4
Medium conditions
Dielectric constant εr > 1.4
Process temperature range -40 to +200 °C (-40 to +392 °F)
Vessel Pressure 0.5 bar g (7.25 psi g) maximum
Design
Weight Approx. 6.1 kg (13.4 lbs) with 3"
universal flange
Materials
• Enclosure Die-cast aluminum, painted
• Degree of protection IP67/Type 4X/NEMA 4X/
Type 6/NEMA 6
• Cable inlet 2x M20x1.5 or ½" NPT
Process connections
• Universal flanges, 316L stainless 3"/80 mm, 4"/100 mm, 6"/150 mm
steel, flat faced, with integral Easy (mates with flange EN 1092-1,
Aimer ASME B16.5, or JIS B2238 bolt
pattern), 0.5 bar g (7.25 psi g)
max. pressure
Programming
Intrinsically Safe Siemens handheld Infrared receiver
programmer
(ordered separately)
- Approvals for handheld pro- IS model with ATEX II 1G EEx ia
grammer IIC T4, CSA/FM Class I, Div. 1,
Groups A, B, C, D T6 @ max.
ambient temperature of +40 °C
(+104 °F)
Handheld communicator HART Communicator 375
PC SIMATIC PDM
Display (local) Alphanumeric LCD for readout
and entry

5/222 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR460

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LR460 C) 7 M L 5 4 2 6 - SITRANS LR460 C) 7 M L 5 4 2 6 -
4-wire, 24 GHz FMCW radar level transmitter with 0 7 7 7 0 - 77 7 0 4-wire, 24 GHz FMCW radar level transmitter with 0 7 7 7 0 - 77 7 0
extremely high signal-to-noise ratio and advanced extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of sol- signal processing for continuous monitoring of sol-
ids up to 100 m (328 ft). It is ideal for measurement ids up to 100 m (328 ft). It is ideal for measurement
in extreme dust. in extreme dust.
Order handheld programmer separately! Order handheld programmer separately!
Process connection Instruction manual
Universal, flat faced, 0.5 bar g (7.25 psi g) maxi- English C) 7ML1998-5JM02
mum with integral Easy Aimer ball German C) 7ML1998-5JM32
3" (80 mm) A Multi-language Quick Start manual C) 7ML1998-5QW82
4" (100 mm) B This device is shipped with the Siemens Milltronics
6" (150 mm) C manual CD containing the complete ATEX Quick
Start and instruction manual library.
Antenna
3" horn antenna, fits 80 mm (3") nozzles A Accessories
3" horn antenna, fits 80 mm (3") nozzles with B Handheld programmer, Infra-red, Intrinsically Safe, 7ML5830-2AJ
100 mm extension EEx ia
3" horn antenna, fits 80 mm (3") nozzles with C Dust cap, PTFE, for 3"/80 mm horn 7ML1930-1BL
200 mm extension Dust cap, PTFE, for 4"/100 mm horn 7ML1930-1BM
3" horn antenna, fits 80 mm (3") nozzles with D HART modem/RS-232 (for use with a PC and D) 7MF4997-1DA
500 mm extension1) SIMATIC PDM)
3" horn antenna, fits 80 mm (3") nozzles with E HART modem/USB (for use with a PC and D) 7MF4997-1DB
1000 mm extension1)
4" horn antenna, fits 100 mm (4") nozzles F
SIMATIC PDM)
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AP 5
+80 °C (-40 to +176 °F) (available for HART only -
4" horn antenna, fits 100 mm (4") nozzles with G two cable glands required)
100 mm extension
One metallic cable gland M20x1.5, rated -40 to 7ML1930-1AQ
4" horn antenna, fits 100 mm (4") nozzles with H +80 °C (-40 to +176 °F) with integrated shield con-
200 mm extension nection (available for PROFIBUS PA)
4" horn antenna, fits 100 mm (4") nozzles with J SITRANS RD100 Remote display - see RD100 on
500 mm extension1) page 5/292
4" horn antenna, fits 100 mm (4") nozzles with K SITRANS RD200 Remote display - see RD200 on
1000 mm extension1) page 5/294
Purge (self-cleaning) connection 1) Available with Purge option 0 only
No purge connection 0
C) Subject to export regulations AL: N, ECCN: EAR99
Purge connection 1
D) Subject to export regulations AL: N, ECCN: EAR99H
Output/Communication
4 to 20 mA, HART® 0 Note 1: available with no pressure rating, 0.5 bar g maximum.
PROFIBUS PA 1 Please contact nacc.smpi@siemens.com for special requests.
Power supply/cable inlet
100 to 230 V AC
• 2 x M20x1.5 A
• 2 x ½“ NPT B
24 V DC
• 2 x M20x1.5 C
• 2 x ½“ NPT D
Approvals
General Purpose, CSAUS/C, Industry Canada, FM, A
FCC, CE and R&TTE, C-TICK
CSA/FM Class II, Div. 1, Groups E, F, and G, B
Class III
ATEX II 1/2 D T6, CE, R&TTE C
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Manufacturer’s test certificate M to DIN 55350, C11
Part 18 and to ISO 9000
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text

March 2009 Siemens FI 01 · 2009 US Edition 5/223


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR460

■ Dimensional drawings

SITRANS LR460 dimensions

5/224 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR460

■ Schematics

SITRANS LR460 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/225


© Siemens AG 2009

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR260 and SITRANS LR460 Specials

■ Selection and Ordering Data


SITRANS LR260 and SITRANS LR460 Specials LR460 enclosure with board stack, PROFIBUS PA A5E02212424
Process connection part kits - non-pressure-rated communication, AC power, NPT cable inlet,
approval option A, no process connection
LR260/LR460,100 mm horn extension, no purge, A5E01087872
see Note 1 LR460 enclosure with board stack, HART commu- A5E02212425
nication, DC power, M20 cable inlet, approval
LR260/LR460, 200 mm horn extension, no A5E01091262 option A, no process connection
purge, see Note 1
LR460 enclosure with board stack, PROFIBUS PA A5E02212426
LR260/LR460,100 mm extension with purge, A5E01261979 communication, DC power, M20 cable inlet,
see Note 1 approval option A, no process connection
LR260/LR460, 200 mm extension with purge, A5E01261981 LR460 enclosure with board stack, HART commu- A5E02212428
see Note 1 nication, DC power, NPT cable inlet, approval
option A, no process connection
LR260/LR460, horn 2", no purge, no emitter, A5E02083905
see Note 1 LR460 enclosure with board stack, PROFIBUS PA A5E02212429
communication, DC power, NPT cable inlet,
LR260/LR460, horn 3", no purge, no emitter, A5E01623511 approval option A, no process connection
see Note 1
LR260/LR460, horn 4", no purge, no emitter, A5E01623512 Note 1: available with no pressure rating, 0.5 bar g maximum.
see Note 1 Please contact nacc.smpi@siemens.com for special requests.
LR260/LR460, horn 2", with purge, no emitter, A5E02083906
see Note 1
LR260/LR460, horn 3", with purge, no emitter, A5E01623513
see Note 1
5 LR260/LR460, horn 4", with purge, no emitter,
see Note 1
A5E01623514

LR260/LR460, 4" universal flat faced flange, A5E01259467


see Note 1
LR260/LR460, 6" universal flat faced flange, A5E01261834
see Note 1
LR260/LR460 O-Rings for Easy Aimer, see A5E01261836
Note 1
Purge conversion kit - non-pressure-rated (no
flange or extension included)
LR260/LR460 purge conversion, 2" horn, A5E02083914
see Note 1
LR260/LR460 purge conversion, 3" horn, A5E02083915
see Note 1
LR260/LR460 purge conversion, 4" horn, A5E02083916
see Note 1
Enclosure with electronics

LR260 enclosure with board stack, HART com- A5E02203605


munication, M20 cable inlet, approval option A,
no process connection
LR260 enclosure with board stack, PROFIBUS A5E02213423
PA communication, M20 cable inlet, approval
option A, no process connection
LR260 enclosure with board stack, HART com- A5E02165924
munication, NPT cable inlet, approval option A,
no process connection
LR260 enclosure with board stack, PROFIBUS A5E02213428
PA communication, NPT cable inlet, approval
option A, no process connection
LR460 enclosure with board stack, HART com- A5E02182085
munication, AC power, M20 cable inlet, approval
option A, no process connection
LR460 enclosure with board stack, PROFIBUS A5E02212422
PA communication, AC power, M20 cable inlet,
approval option A, no process connection
LR460 enclosure with board stack, HART com- A5E02212423
munication, AC power, NPT cable inlet, approval
option A, no process connection

5/226 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

■ Overview Interface Detection


The SITRANS LG200, when used with the Model 7ML1301-6 co-
Introduction axial probe, is a transmitter capable of measuring both an upper
Guided Wave Radar transmitters combine TDR (time domain re- level and an interface level. The upper liquid must have a dielec-
flectometry), ETS (equivalent time sampling) and modern low tric constant between 1.4 and 5 and the two liquids have a dif-
power circuitry. ference in dielectric constants greater than 10. A typical appli-
cation would be oil over water, with the upper layer of oil being
Time Domain Reflectometry (TDR) non-conductive with a dielectric constant of approximately 2 and
the lower layer of water being very conductive with a dielectric
TDR uses pulses of electromagnetic (EM) energy to measure constant of approximately 80. This interface measurement can
distances or levels. When a pulse reaches a dielectric disconti- only be accomplished when the dielectric constant of the upper
nuity (created by media surface), part of the energy is reflected. medium is lower than the dielectric constant of the lower me-
The greater the dielectric difference, the greater the amplitude dium.
(strength) of the reflection.
In the SITRANS LG200 transmitter, a waveguide with a charac-
teristic impedance in air is used as a probe. When part of the
probe is immersed in a material other than air, there is lower im-
pedance due to the increase in the dielectric. When an EM pulse
is sent down the probe and meets the dielectric discontinuity, a
reflection is generated.
Equivalent Time Sampling (ETS)
ETS (Equivalent Time Sampling) is used to measure the high
speed, low power EM energy. ETS is critical in the application of
TDR to vessel level measurement technology. The high speed
EM energy (1000 ft/µs) is difficult to measure over short dis- 5
tances and at the resolution required in the process industry.
ETS captures the EM signals in real time (nanoseconds) and re-
constructs them in equivalent time (milliseconds), which is much
easier to measure with today’s technology.
ETS is accomplished by scanning the waveguide to collect thou-
sands of samples. Approximately 8 scans are taken per second;
each scan gathers more than 30,000 samples.

March 2009 Siemens FI 01 · 2009 US Edition 5/227


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

5/228 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Guided Wave Radar (Interface) Application Questionnaire


Customer information
Contact: Prepared By:
Company: Date:
Address: Notes on the Application:
City: Country:
Zip/Postal Code: Phone: ( )
E-mail: Fax: ( )

Tank/Vessel Information (supply sketch where possible) Sketch Tank dimensions:


attached Height: m/ft
Tank top: Tank bottom: Mounting location: Diameter: m/ft

Open Sloped Top mount Nozzle Length: cm/in 5


Flat Flat Thread mount Nozzle Diameter: cm/in
Conical Conical Flange mount Process connection type:
Parabolic Parabolic Bypass/Sidepipe Mount Process connection size:
Pipe mount Distance to sidewall: cm/in
Pressure:
Displacer replacement
Normal: (please supply drawings)

Maximum (relief):

Interface Data
Upper material: Lower material: Emulsion layer: Yes
Upper material thickness: cm/in Lower material thickness: cm/in No (preferred)
Upper material dielectric: Lower material dielectric: Emulsion thickness: cm/in

Material
Material being measured: Liquid Slurry
Material temperature: Norm: °C/°F Max: °C/°F
Coating buildup: Yes No Turbulence: Yes No
3
Maximum Viscosity: Density: kg/m
Kinematic Viscosity (cSt) = Dynamic Viscosity (cP) / Density (kg/m3) upper
emulsion material
1 to 5 cSt (like water) 50 to 100 cSt (like honey) layer
lower
5 to 20 cSt (like machine oil) 100 to 500 cSt (like syrup/molasses) material
20 to 50 cSt (like cooking oil) >500 cSt (like tar)

Installation
Power available: Outputs required: 4 to 20 mA
Communications: HART ® /4 to 20 mA Other (please specify)

Products recommended:
© Siemens Milltronics Process Instruments Inc. www.siemens.com/processautomation Form# 2-938R0

March 2009 Siemens FI 01 · 2009 US Edition 5/229


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

■ Overview

SITRANS LG200 is a guided wave radar transmitter for short and


medium range level, level/interface and volume measurement of

5 liquids and solids. It is unaffected by changes in process condi-


tions, high temperatures and pressures, and steam.

■ Benefits
• Coaxial, rigid, and flexible single or twin rods for many appli-
cations
• Measures accurately on materials with dielectric (dK) as low
as 1.4
• Guided wave radar measurement for up to 2.5 mm (0.12”) ac-
curacy
• Measures level and interface on challenging applications in-
cluding foam
• 3 button programming for quick setup
• Reliable level measurement on harsh applications with pres-
sure up to 430 bar g (6250 psi g) and temperatures as high as
+427 °C (+800 °F).

■ Application
SITRANS LG200 provides accurate measurement in level, vol-
ume, and interface applications. For short and extended appli-
cations, LG200 offers coaxial, single or twin rod probes, and sin-
gle or twin cable probes up to 22.5 m (75 ft).
SITRANS LG200 measures accurately in liquid or slurry applica-
tions of corrosive vapors, foam, saturated steam, high viscosity,
quick fill/empty rates, low levels and varying dielectrics and
product densities.
Ideal for retrofitting torque tube applications, SITRANS LG200
chamber replacement probe can be mounted in existing cham-
bers or cages for optimal measurement.
• Key applications: hydrocarbon processing, interface/level
measurement, low dielectric liquids, high temperature/pres-
sure applications, powdered solids with high angle of repose.

5/230 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

■ Configuration

SITRANS LG200 installation

March 2009 Siemens FI 01 · 2009 US Edition 5/231


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

■ Technical specifications Programming


Local Three button, menu-driven data
Mode of operation entry with security passwords
Measuring principle Guided wave radar measurement Remote SIMATIC PDM via HART
Measuring range 0.15 to 22.5 m (0.5 to 75 ft) Power 11 to 36 V DC
Output Certificates and approvals
mA analog output with HART digital Optically isolated 4 to 20 mA, • General Purpose CSAUS/C, CE, C-TICK
signal 620 Ω max.
• Intrinsically Safe FM Class I, Div. 1, Groups A, B, C
Output range and D, Class II, Div. 1, Groups E,
• Analog 3.8 to 20.5 mA usable F, and G T4, Class III, Type 4 IP65
• Start-up current 4.0 mA CSA Class I, Div. 1, Groups A, B,
C, and D, Class II, Div. 1, Groups
Diagnostic alarm Adjustable 3.6 mA, 22 mA, HOLD E, F, and G T 4, Class III, Type 4
Digital communication HART® Version 5.x and Multidrop ATEX II 1G EEx ia IIC T4
compatible • Explosion Proof/Flame Proof FM Class I, Div 1, Groups B, C,
Performance and D, Class II, Div. 1, Groups E,
F, and G T4, Class III, Type 4 IP65
Non-linearity
CSA Class I, Div. 1, Groups B to
• Coaxial/twin rod probes < 0.1% of probe length or 2.5 mm D, Class II, Div. 1, Group E, F, and
(0.1”), whichever is greater G T4, Class III, Type 4
• Single rod probes < 0.3% or 8 mm (0.3”), whichever ATEX II 1/2 GD EEx d [ia] IIC T6
is greater • Non-Incendive FM Class I, Div. 2, Groups A, B,
5 • Interface models Upper layer: ± 25.4 mm (1”)
Interface layer: ± 25.4 mm (1”)
C, and D, Class II, Div. 2, Groups
F, G T4, Class III, Type 4 IP65
(distinct interface surface CSA Class I, Div. 2, Groups A, B,
required) C, and D, Class II, Div. 2, Groups
E, F, and G T4, Class III, Type 4
Resolution and repeatability ≤ 2.5 mm (0.1”)
• Non-Sparking ATEX II 3G EEx nA (nL) IIC
Electromagnetic compatibility Meets CE requirements (EN T4 to T6
61000-6-2/2001,
EN 6100-6-4/2001) ATEX II 3G EEx nA II T4 to T6
(Single and Twin Rod probes • Others Functional Safety to SIL-1 in
must be used in metallic vessel or accordance with IEC 61508 -Safe
stilling well to maintain CE compli- Failure Fraction (SFF) of 85.5 %
ance.) Functional Safety to SIL-2 in
Rated operating conditions1) accordance with IEC 61508 -Safe
Failure Fraction (SFF) of 91 %
• Ambient temperature for enclosure -40 to +80 °C (-40 to +176 °F) (Third party FMEDA Analysis -
• LCD readable temperature range -20 to +70 °C (-5 to +160 °F) hardware only)
• Location Indoor/outdoor 1)
If installation is in areas classified as hazardous, please observe relevant
certificates
• Installation category II 2)
Temperature rating is pressure dependent
• Pollution degree 2 3)
Pressure rating is temperature dependent
Medium conditions1)
Dielectric constant dK ≥ 1.4
Process temperature range2) -196 to +427 °C (-321 to +800 °F)
Vessel pressure3) Full vacuum to 431 bar g
(6250 psi g), probe dependent
Design
Weight of transmitter with solid lid 1.28 kg (2.83 lbs)
Weight of transmitter with glass win-
dow lid 1.60 kg (3.52 lbs)
Materials
• Enclosure Aluminum, epoxy-coated
• Degree of protection Type 4/NEMA 4, IP65
• Cable inlet 2x M20x1.5 or 2 x ½” NPT
Process connections
• Threaded G ¾” [(BSPP), EN ISO 228-1], 1”,
1½”, 2” NPT [(Taper), ANSI/ASME
B1.20.1] and G 2” [(BSPP),
EN ISO 228-1]
• Flanged 3/4” to 4”, ASME, DIN flanges

5/232 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200 - probe types

Coaxial Probe Coaxial HT/HP Probe Coaxial HP Probe Coaxial Overfill/Flooded Cage
(7ML1301-1) (7ML1301-2) (7ML1301-3) Probe (7ML1301-4)
Model reference 7xA-x 7xD-x 7xP-x 7xR-x
number
Recommended General purpose: clean, Clean, high temperature/high Clean, high pressure liquids Overfill, temperatures to
applications: low viscosity liquids pressure liquids > +200 °C < +200 °C (+400 °F) +200 °C (+400 °F), clean, low
< +150 °C (+300 °F) (+400 °F), ammonia, chlorine viscosity liquids, dis-
placer/torque-tube replacement
Not recommended Coating and buildup, foam Coating and buildup, foam, Coating and buildup, foam, Coating and buildup, foam
for: steam steam
Materials/wetted parts 316 L SS, TFE spacers, 316L SS, Alumina spacers 316L SS, TFE spacers, 316L SS, TFE spacers, O-ring1)
O-ring1) (option PEEK or TFE), Borosilicate
Borosilicate
Process seal O-ring1) Borosilicate (no O-ring) Borosilicate (no O-ring) O-ring1)
Rod/tube diameter:
Standard ø 8 mm (0.3125”) rod ø 8 mm (0.3125”) rod ø 8 mm (0.3125”) rod ø 8 mm (0.3125”) rod
ø 22 mm (0.875”) tube ø 22 mm (0.875”) tube ø 22 mm (0.875”) tube ø 22 mm (0.875”) tube
Enlarged ø 15 mm (0.63”) rod ø 15 mm (0.63”) rod ø 15 mm (0.63”) rod ø 15 mm (0.63”) rod
ø 45 mm (1.75”) tube ø 45 mm (1.75”) tube ø 45 mm (1.75”) tube ø 45 mm (1.75”) tube
Process connection
thread:
¾” NPT [(Taper), ¾” NPT [(Taper), ANSI/ASME ¾” NPT [(Taper), ANSI/ASME ¾” NPT [(Taper), ANSI/ASME
5
Standard
ANSI/ASME B1.20.1], B1.20.1], G 1” [(BSPP), B1.20.1], G 1” [(BSPP), B1.20.1], G 1” [(BSPP),
G 1” [(BSPP), EN ISO 228-1] EN ISO 228-1] EN ISO 228-1]
EN ISO 228-1]
Enlarged 2” NPT [(Taper), 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME
ANSI/ASME B1.20.1] B1.20.1] B1.20.1] B1.20.1]
Flange ASME
(EN/DIN):
Standard 1 to 4” (DN 25 to 100) 1 to 4” (DN 25 to 100) 1 to 4” (DN 25 to 100) 1 to 4” (DN 25 to 100)
Enlarged 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100)
Length 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”)
Transition zone: 25 mm (1”) @ dk = 1.4 none 25 mm (1”) @ dk = 1.4 none
Top 150 mm (6”) @ dk = 80 150 mm (6”) @ dk = 80
Transition zone: 150 mm (6”) @ dk = 1.4 150 mm (6”) @ dk = 1.4 150 mm (6”) @ dk = 1.4 150 mm (6”) @ dk = 1.4
Bottom 25 mm (1”) @ dk = 80 25 mm (1”) @ dk = 80 25 mm (1”) @ dk = 80 25 mm (1”) @ dk = 80
Process temperature +150 °C @ 27 bar g +427 °C @ 133 bar g +200 °C @ 379 bar g +200 °C @ 18 bar g
maximum (+300 °F @ 400 psi g) (+800 °F @ 2000 psi g) (+400 °F @ 5500 psi g) (+400 °F @ 270 psi g)
Process temperature -40 °C @ 70 bar g -196 °C @ 430 bar g -196 °C @ 430 bar g -40 °C @ 70 bar g
minimum (-40 °F @ 1000 psi g) (-321 °F @ 6250 psi g) (-321 °F @ 6250 psi g) (-40 °F @ 1000 psi g)
Process pressure 70 bar g @ +20 °C 431 bar g@ +20 °C 431 bar g@ +20 °C 70 bar g @ +20 °C
maximum (1000 psi g @ +70 °F) (6250 psi g @ +70 °F) (6250 psi g @ +70 °F) (1000 psi g @ +70 °F)
Process pressure Yes, not hermetic2) Yes, hermetic Yes, hermetic Yes, not hermetic
minimum/vacuum (<10-8 cc/sec @ 1 atmo- (<10-8 cc/sec @ 1 atmo-
service sphere) sphere)
Dielectric range 1.4 to 100 1.4 to 100 1.4 to 100 1.4 to 100
Maximum viscosity
(cP)
Standard 500 500 500 500
Enlarged 1500 1500 1500 1500
Coating/buildup No No No No
Foam No No No No
Corrosives Yes Yes Yes Yes
Sanitary No No No No
Overfill No Yes No Yes
1)
See O-Ring Selection Guide for guidance
2)
Not hermetic: sealing by means of O-ring. Hermetic: sealing by means of borosilicate glass window
®Viton is a registered trademark of DuPont Dow Elastomers
®Hastelloy is a registered trademark of Haynes International
®Kalrez is a registered trademark of DuPont Dow Elastomers
®Monel is a registered trademark of Special Metals Corporation

March 2009 Siemens FI 01 · 2009 US Edition 5/233


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200 - probe types

Coaxial Steam Probe Coaxial Interface Probe Single Rigid Rod Probe Single Rigid Rod Single Rigid Rod Probe,
(7ML1301-5) (7ML1301-6) (7ML1303-1) HT/HP Probe PFA rod insulation
(7ML1303-2) (7ML1303-1J)
Model reference 7xS-x 7xT-x 7xF-x 7xJ-x 7xF-4
number
Recommended Hot water (steam) Liquid/liquid-interface, Coating and buildup, Coating and buildup, Excessive coating and
applications: >+200 °C (+400 °F) temperatures to +200 °C foam foam buildup, foam
(external chamber is (+400 °F); clean, low-vis-
required for use in boil- cosity liquids
ers)
Not recommended General purpose, coat- Coating and buildup, Low dielectric media Low dielectric media Low dielectric media
for: ing and buildup, foam foam (dK < 10)1) (dK < 10)1) (dK < 10)1)
2)
Materials/wetted 316L SS, 316L SS, TFE spacers, 316L SS, PTFE, O-ring 316L SS, TFE, O-ring 316L SS, PFA, PTFE,
parts PEEK spacers, Aegis O-ring 2) 2)
O-ring2)
2)
PF128 O-ring
Process seal Aegis PF128 O-ring2), O-ring2) O-ring2) Aegis PF128 O-ring O-ring2)
PEEK only only2)
Rod/Tube diameter:
Standard ø 8 mm (0.3125”) rod ø 8 mm (0.3125”) rod ø 12 mm (0.5”) rod ø 12 mm (0.5”) rod ø 12 mm (0.5”) rod
ø 22 mm (0.875”) tube ø 22 mm (0.875”) tube ø 16 mm (0.625”) insulation
Enlarged N/A ø 15 mm (0.63”) rod N/A N/A N/A
ø 45 mm (1.75”) tube
Process connection
thread:

5 Standard ¾” NPT [(Taper), ¾” NPT [(Taper),


ANSI/ASME B1.20.1], ANSI/ASME B1.20.1],
¾” NPT [(Taper),
ANSI/ASME B1.20.1],
¾” NPT [(Taper),
ANSI/ASME B1.20.1],
2” NPT [(Taper),
ANSI/ASME B1.20.1],
G 1” [(BSPP), G 1” [(BSPP), G 1” [(BSPP), G 1” [(BSPP), G 2” [(BSPP),
EN ISO 228-1] EN ISO 228-1] EN ISO 228-1] EN ISO 228-1] EN ISO 228-1]
Enlarged N/A 2” NPT [(Taper), 2” NPT [(Taper), 2” NPT [(Taper), N/A
ANSI/ASME B1.20.1] ANSI/ASME B1.20.1] ANSI/ASME B1.20.1]
Flange ASME
(EN/DIN): 1 to 4” (DN 25 to 100) 1 to 4” (DN 25 to 100) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100)
Standard N/A 2 to 4” (DN 50 to 100) N/A N/A N/A
Enlarged
Length 60 to 455 cm 60 to 610 cm 60 to 610 cm 60 to 610 cm 60 to 610 cm
(24 to 180”) (24 to 240”) (24 to 240”) (24 to 240”) (24 to 240”)
Transition zone: 25 mm (1”) @ dk ≥ 10 none Blocking distance: 12 to Blocking distance: 12 to Blocking distance: 12 to
Top 91 cm (4.8 to 36”), 91 cm (4.8 to 36”), 91 cm (4.8 to 36”), probe
probe length depen- probe length depen- length dependent
dent dent
Transition zone: 25 mm (1”) @ dk ≥ 10 150 mm (6”) @ dk = 1.4 25 mm (1”) @ dk >10 25 mm (1”) @ dk >10 25 mm (1”) @ dk >10
Bottom 25 mm (1”) @ dk = 80
Process +343 °C @ 165 bar g +200 °C @ 18 bar g +150 °C @ 27 bar g +316 °C @ 165 bar g +150 °C @ 27 bar g
temperature (+650 °F @ 2400 psi g) (+400 °F @ 270 psi g) (+300 °F @ 400 psi g) (+605 °F @ 2400 psi g) (+300 °F @ 400 psi g)
maximum (saturated steam)
Process -40 °C @ 207 bar g -40 °C @ 70 bar g -40 °C @ 70 bar g -40 °C @ 70 bar g -40 °C @ 50 bar g
temperature (-40 °F @ 3000 psi g) (-40 °F @ 1000 psi g) (-40 °F @ 1000 psi g) (-40 °F @ 1000 psi g) (-40 °F @ 750 psi g)
minimum
Process pressure 165 bar g @ +343 °C 70 bar g @ +20 °C 70 bar g @ +20 °C 207 bar g @ +20 °C 70 bar g @ +20 °C
maximum (2400 psi g @ +650 °F) (1000 psi g @ +70°F) (1000 psi g @ +70 °F) (3000 psi g @ +70 °F) (1000 psi g @ +70 °F)
Process pressure Yes, not hermetic Yes, not hermetic Not suitable Not suitable Not suitable
minimum/vacuum
service
Dielectric range 10 to 100 Upper liquid layer 1.4 to 5 1.9 to 1001) 1.9 to 1001) 1.9 to 1001)
Interface liquid layer 15 to
100
Maximum viscosity
Standard 500 cP 500 cP
Enlarged N/A 1500 cP 10000 cP (consult factory if severe agitation/turbulence)
Coating/buildup No No Yes, maximum error 10% of coated length;% error related to dielectric of
media, thickness of coating and coated probe length above media
Foam No No Yes Yes Yes
Corrosives Yes Yes Yes Yes Yes
Sanitary No No No No No
Overfill Yes Yes No No No
1)
With dK of 1.9 to 10, the device must be mounted between 50 and 150 mm (2 to 6”) of metal tank wall or in chamber/bridle
2)
See O-ring Selection Guide for guidance

5/234 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200 - probe types

Single Rigid Rod Probe, Single Rigid Rod Probe, PFA Single Flexible Rod Probe Single Flexible Rod Probe for
Sanitary (7ML1303-1D) faced flange(7ML1303-1E) (7ML1304-1) Bulk Solids (7ML1304-2)
Model reference 7xF-E 7xF-F 7x1-x 7x2-x
number
Recommended Applications demanding Extreme corrosives, coat- Coating and buildup, foam; Granular bulk solids applica-
applications: sanitary specifications ing/buildup, foam lengths > 6 m (20 ft) headroom tions (powders, grain, dust)
3000 lb pull down force
Not recommended Low dielectric media Low dielectric media Low dielectric media (dK < 4) Solids with dK < 4
for: (dK < 10)1) (dK < 10)1)
Materials/wetted parts 316L SS, TFE, 15 Ra finish All PFA - wetted surfaces 316L SS, TFE, O-ring2) 316L SS, TFE, O-ring2)
Optional AL6XN SS N/A N/A N/A
Process seal 316L SS, TFE, no O-ring2) PFA, no O-ring O-ring2) Sealant
Rod/tube diameter ø 12 mm (0.5”) rod ø 12 mm (0.5”) rod ø 5 mm (0.188”) cable ø 6 mm (0.25”) cable
ø 16 mm (0.625”) insulation
Process connection N/A N/A 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME
thread B1.20.1], G 2” [(BSPP), B1.20.1], G 2” [(BSPP),
EN ISO 228-1] EN ISO 228-1]
Flange ASME 19 to 100 mm (¾ to 4”) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100)
(EN/DIN) Triclover-style 16 amp fitting
Length 60 to 610 cm (24 to 240”) 60 to 610 cm (24 to 240”) 1 to 22.5 meters (3 to 75 ft) 1 to 22.5 meters (3 to 75 ft)
Blocking distance: 0 to Blocking distance: 12 to 91 cm Blocking distance: 12 to 91 cm Blocking distance: 12 to 91 cm
5
Transition zone:
Top 91 cm (0 to 36”), probe (4.8 to 36”), probe length (4.8 to 36”), probe length (4.8 to 36”), probe length
length dependent dependent dependent dependent
Transition zone: 25 mm (1”) @ dk >10 25 mm (1”) @ dk >10 305 mm (12”) 305 mm (12”)
Bottom
Process temperature +150 °C @ 5.1 bar g +150 °C @ 27 bar g +150 °C @ 27 bar g +66 °C @ 3.4 bar g
maximum (+300 °F @ 75 psi g) (+300 °F @ 400 psi g) (+300 °F @ 400 psi g) (+150 °F @ 50 psi g)
Process temperature 0 °C at 5.1 bar g -40 °C @ 13.7 bar g -40 °C @ 70 bar g -40 °C @ 3.4 bar g
minimum (+32 °F at 75 psi g) (-40 °F @ 200 psi g) (-40 °F @ 1000 psi g) (-40 °F @ 50 psi g)
Process pressure 5.1 bar g @ +150 °C 70 bar g @ +20 °C 70 bar g @ +20 °C 3.4 bar g +66 °C
maximum (75 psi g @ +300 °F) (1000 psi g @ +70°F) (1000 psi g @ +70 °F) (50 psi g @ +150 °F)
Process pressure Not suitable for vacuum applications
minimum/vacuum
service
Dielectric range 1.9 to 1001) 1.9 to 1001) 4 to 1001) 4 to 100
Maximum viscosity 10000 (consult factory if severe agitation/turbulence) N/A
(cP)
Coating/buildup Yes, maximum error 10% of coated length;% error related to dielectric of media, thickness of coating and coated probe
length above media
Foam Yes Yes Yes Yes
Corrosives No Yes No No
Sanitary Yes No No No
Overfill No No No No
1)
With dK of 1.9 to 10, the device must be mounted between 50 and 150 mm (2 to 6”) of metal tank wall or in chamber/bridle
2)
See O-ring Selection Guide for guidance

March 2009 Siemens FI 01 · 2009 US Edition 5/235


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200 - probe types

Twin Rod Probe Flexible Twin Rod Probe Flexible Twin Rod Bulk Solids Probe
(7ML1302-1) (7ML1302-3) (7ML1302-2)
Model reference 7xB-x 7x7-x 7x5-x
number
Recommended applications: General purpose, foam, minor Low dielectric media (1.9 to 10) with Granular light bulk solids applications
film coating lengths > 6 m (20 ft) (powders, grains, dust), 3000 lbs pull-
down force
Not recommended for: Media bridging between rods Dielectric > 10: media bridging on flexible Media bridging flexible elements
or building up on spacers elements
Materials/wetted parts 316L SS, TFE spacers, O- 316L SS, FEP webbing, O-ring1) 316L SS, FEP webbing, O-ring1)
ring1)
Process seal O-ring1) O-ring1) Sealant
Rod/tube diameter Two, ø 12 mm (0.5”) rod; Two, ø 6 mm (0.25”) cables; 22 mm Two, ø 6 mm (0.25”) cables; 22 mm
22 mm (0.875”) CL to CL (0.875”) CL to CL (0.875”) CL to CL
Process connection thread 2” NPT [(Taper), ANSI/ASME 2” NPT [(Taper), ANSI/ASME B1.20.1], 2” NPT [(Taper), ANSI/ASME B1.20.1],
B1.20.1], G 2” [(BSPP), G 2” [(BSPP), EN ISO 228-1] G 2” [(BSPP), EN ISO 228-1]
EN ISO 228-1]
Flange ASME (EN/DIN) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100) 2 to 4” (DN 50 to 100)
Length 60 to 610 cm (24 to 240”) 1 to 22.5 m (3 to 75 ft) 1 to 22.5 m (3 to 75 ft)
Transition zone2):
Top 150 mm (6”) @ dK > 1.9 150 mm (6”) @ dK > 1.9 150 mm (6”) @ dK > 1.9
Blocking distance: none Blocking distance: 12 to 50 cm (4.8 to 20”) Blocking distance: 12 to 50 cm (4.8 to 20”)
150 mm (6”) @ dK = 1.9 305 mm (12”) 305 mm (12”)
5
Transition zone:
Bottom 25 mm (1”) @ dK = 80
Process temperature max.3) +200 °C @ 19 bar g (+400 °F @ 275 psi g) +66 °C @ 3.4 bar g
(+ 150 °F @ 50 psi g)
Process temperature min. -40 °C @ 70 bar g (-40 °F @ 1000 psi g) -40 °C @ 3.4 bar g (-40 °F @ 50 psi g)
Process pressure max. 70 bar g @ +20 °C (1000 psi g @ +70 °F) 3.4 bar g @ +66 °C (50 psi g @ + 150 °F)
Process pressure Yes, not hermetic Not suitable
min./vacuum service
Dielectric range 1.9 to 100 1.9 to 100 1.9 to 100
Maximum viscosity (cP) 1500 1500 Not suitable
Coating/buildup Yes, maximum error 3% of coated length with conductive media
Bridging not recommended.4)
Foam Yes Yes Yes
Corrosives Yes No Yes
Sanitary No No No
Overfill No No No
1)
See O-ring Selection Guide for guidance
2)
Transition zone is dielectric dependent: dK = dielectric permittivity. Unit will function but accuracy will decrease in Transition Zone
3) Refer to Ambient Temperature vs Process Temperature graphs or instruction manual
4) Bridging is defined as continuous accumulation of material between the probe elements

O-ring and Seal Selection Guide (maximum temperature of O-ring is not maximum process temperature)
Material Maximum Minimum Recommended for Use in: Not Recommended for Use In:
Temperature Temperature
Viton GFLT +200 °C @ 16 bar g -40 °C (-40 °F) General purpose, steam, ethylene Ketones (MEK, acetone), skydrol fluids,
(+400 °F @ 232 psi g) amines, anhydrous ammonia, low
molecular weight esters and ethers, hot
hydrofluoric or chlorosulfuric acids, sour
HCs
EPDM +125 °C @ 14 bar g -50 °C (-60 °F) Acetone, MEK, skydrol fluids Petroleum oils, di-ester base lubricants,
(+250 °F @ 200 psi g) propane, steam, anhydrous ammonia
Kalrez (4079) +200 °C @ 16 bar g -40 °C (-40 °F) Inorganic and organic acids (including HF Black liquor, hot water/steam, hot aliphatic
(+400 °F @ 232 psi g) and nitric) aldehydes, ethylene, glycols, amines, ethylene oxide, propylene oxide,
organic oils, silicone oils, vinegar, sour HCs molten sodium, molten potassium,
anhydrous ammonia
Aegis PF128 +200 °C @ 16 bar g -20 °C (-4 °F) Inorganic and organic acids (including HF Black liquor, Freon 43, Freon 75, Galden,
(+400 °F @ 232 psi g) and nitric) aldehydes, ethylene, glycols, KEL-F liquid, molten sodium, molten
organic oils, silicone oils, vinegar, sour potassium, anhydrous ammonia
HCs, steam, amines, ethylene oxide,
propylene oxide
Borosilicate +427 °C @ 135 bar g -196 °C (-321 °F) General high temperature/high pressure Hot alkaline solutions, HF acid, media with
(HT/HP probes (+800 °F @ 2000 psi g) applications, hydrocarbons, full vacuum pH>12
only) (hermetic), anhydrous ammonia

5/236 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Transmitter C) 7 M L 1 3 0 0 - SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 -
A guided wave radar transmitter for short and 7 7 7 1 7 - 77 A 0 SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 77 7 0
medium range level, level/interface, and volume standard applications. Coaxial probes yield robust
measurement of liquids and solids, including high signal strength even in extremely low dielectric
temperature and pressure applications, and steam. applications (dK 1.4 to 100).

Note: Note:
In addition to the transmitter, please select a For orders of 10 or more, please consult factory
probe configuration to complete the Model
SITRANS LG200 (ordered separately).
Coaxial1) 2) 1
For orders of 10 or more, please consult factory Coaxial, High Temperature/High Pressure2) 3) 2
Power Coaxial, High Pressure2) 3) 3
24 V DC, 2-wire 1 Coaxial, Overfill/Flooded Cage1) 2) 4
Signal Output Coaxial Steam4) 5) 5
4 to 20 mA HART A Coaxial, Interface1) 2) 6
Options Material of Construction
SIL-1 Approved (FMEDA analysis) SFF = 85.5 % A 316/316L (1.4401/1.4404) stainless steel probe and A
SIL-2 Approved (FMEDA analysis) SFF = 91 % B process connection
Enclosure/lid 316/316L (1.4401/1.4404) SS probe ASME B31.1 D
specifications6)
Aluminum 1
Enlarged Coaxial, 316/316L (1.4401/1.4404) stain- E
Aluminum with glass window 2
less steel probe and process connection7)

5
Cable inlet 316/316L (1.4401/1.4404) stainless steel probe and H
2 x ½” NPT, IP65 0 process connection with PEEK HT spacers8)
2 x M20x1.5, IP65 1 316/316L (1.4401/1.4404) stainless steel probe and J
process connection with Teflon® spacers8)
Approvals (Please select for your region)
Probe Insertion Length
North America
Add order code Y01 and plain text: “Insertion
General Purpose and Intrinsically Safe (CSA/FM A length ... cm”
Class I, Div. 1, Groups A, B, C, and D; Class II,
Div. 1, Groups E, F, and G T4, Class III); Non-incen- Model option 1, 4 and Material of Construction A1
dive (CSA Class I, Div. 2, Groups A, B, C, D, Class option A, E: 60 to 100 cm (23.6 to 39.4")
II, Div. 2, Groups E, F, G; FM Class I, Div. 2, Groups Model option 1, 4 and Material of Construction A2
A, B, C, D, Class II, Div. 2, Groups F, G) option A, E: 101 to 200 cm (39.8 to 78.7")
Model option 1, 4 and Material of Construction A3
Explosion Proof (CSA/FM Class I, Div. 1, Groups B, B option A, E: 201 to 300 cm (79.1 to 118.1")
C, and D; Class II, Div. 1, Groups E, F, and G, T4;
Class III); Non-incendive (CSA Class I, Div. 2, Model option 1, 4 and Material of Construction A4
Groups A, B, C, D, Class II, Div. 2, Groups E, F, G; option A, E: 301 to 400 cm (118.5 to 157.5")
FM Class I, Div. 2, Groups A, B, C, D, Class II, Div. Model option 1, 4 and Material of Construction A5
2, Groups F, G) option A, E: 401 to 500 cm (157.9 to 196.9")
Europe Model option 1, 4 and Material of Construction A6
General Purpose and Intrinsically Safe (ATEX II 1G C option A,E: 501 to 610 cm (197.2 to 240.2")
EEx ia IIC T4) Add order code Y01 and plain text: “Insertion
Explosion Proof (ATEX II 1/2 GD EEx d [ia] IIC T6) D length ... cm”
Non-sparking [ATEX II 3G EEx nA II/EEx nA (nL) IIC E Model options 3, 6 with Material of Construction B1
T4 to T6] option A: 60 to 100 cm (23.6 to 39.4")
Model options 3, 6 with Material of Construction B2
Further designs Order code option A: 101 to 200 cm (39.8 to 78.7")
Please add “-Z” to Order No. and specify Order Model options 3, 6 with Material of Construction B3
code(s). option A: 201 to 300 cm (79.1 to 118.1")
Model options 3, 6 with Material of Construction
For tagging information see probe configurations B4
option A: 301 to 400 cm (118.5 to 157.5")
(additional option Y15)
Model options 3, 6 with Material of Construction B5
Acceptance test certificate: Manufacturer's test C11 option A: 401 to 500 cm (157.9 to 196.9")
certificate M to DIN 55350, Part 18 and ISO 9000 Model options 3, 6 with Material of Construction B6
Instruction manual option A: 501 to 610 cm (197.2 to 240.2")
English C) 7ML1998-5KA01 Add order code Y01 and plain text: “Insertion
length ... cm”
German C) 7ML1998-5KA31
Model options 3, 6 with Material of Construction C1
Multi-language Quick Start manual C) 7ML1998-5XG81
option E: 60 to 100 cm (23.6 to 39.4")
This device is shipped with the Siemens Milltronics Model options 3, 6 with Material of Construction C2
manual CD containing the complete instruction option E: 101 to 200 cm (39.8 to 78.7")
manual library. Model options 3, 6 with Material of Construction C3
C) Subject to export regulations AL: N, ECCN: EAR99
option E: 201 to 300 cm (79.1 to 118.1")

March 2009 Siemens FI 01 · 2009 US Edition 5/237


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 - SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 -
SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 77 7 0 SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 77 7 0
standard applications. Coaxial probes yield robust standard applications. Coaxial probes yield robust
signal strength even in extremely low dielectric signal strength even in extremely low dielectric
applications (dK 1.4 to 100). applications (dK 1.4 to 100).
Note: Note:
For orders of 10 or more, please consult factory For orders of 10 or more, please consult factory
Model options 3, 6 with Material of Construction C4 1½” 600 lb ASME raised face flange CC
option E: 301 to 400 cm (118.5 to 157.5") 1½” 900/1500 lb ASME raised face flange9) CD
Model options 3, 6 with Material of Construction C5 1½” 2500 lb ASME raised face flange9) CE
option E: 401 to 500 cm (157.9 to 196.9") 1½” 600 lb ASME ring joint flange CF
Model options 3, 6 with Material of Construction C6 1½” 900/1500 lb ASME ring joint flange9) CG
option E: 501 to 610 cm (197.2 to 240.2")
1½” 2500 lb ASME ring joint flange9) CH
Add order code Y01 and plain text: “Insertion
length ... cm” 2" 150 lb ASME raised face flange DA
Model option 2 with Material of Construction E1 2" 300 lb ASME raised face flange DB
options A, E, H, J: 60 to 100 cm (23.6 to 39.4") 2" 600 lb ASME raised face flange DC
Model option 2 with Material of Construction E2
options A, E, H, J: 101 to 200 cm (39.8 to 78.7") 2" 900/1500 lb ASME raised face flange9) DD
Model option 2 with Material of Construction E3 2" 2500 lb ASME raised face flange9) DE
options A, E, H, J: 201 to 300 cm (79.1 to 118.1") 2" 600 lb ASME ring joint flange DF
Model option 2 with Material of Construction E4 2" 900/1500 lb ASME ring joint flange9) DG
options A, E, H, J: 301 to 400 cm (118.5 to 157.5") 2" 2500 lb ASME ring joint flange9)
5
DH
Model option 2 with Material of Construction E5
options A, E, H, J: 401 to 500 cm (157.9 to 196.9") 3" 150 lb ASME raised face flange EA
Model option 2 with Material of Construction E6 3" 300 lb ASME raised face flange EB
options A, E, H, J: 501 to 610 cm (197.2 to 240.2") 3" 600 lb ASME raised face flange EC
Add order code Y01 and plain text: “Insertion 3" 900 lb ASME raised face flange9) ED
length ... cm”
3" 1500 lb ASME raised face flange9) EE
Model option 5 with Material of Construction F1
3" 2500 lb ASME raised face flange9) EF
options A, D: 60 to 100 cm (23.6 to 39.4")
Model option 5 with Material of Construction F2 3" 600 lb ASME ring joint flange EG
options A, D: 101 to 200 cm (39.8 to 78.7") 3" 900 lb ASME ring joint flange9) EH
Model option 5 with Material of Construction F3 3" 1500 lb ASME ring joint flange9) EJ
options A, D: 201 to 300 cm (79.1 to 118.1")
3" 2500 lb ASME ring joint flange9) EK
Model option 5 with Material of Construction F4
options A, D: 301 to 400 cm (118.5 to 157.5") 4" 150 lb ASME raised face flange FA
Model option 5 with Material of Construction F5 4" 300 lb ASME raised face flange FB
options A, D: 401 to 455 cm (157.9 to 180") 4" 600 lb ASME raised face flange FC
O-Rings 4" 900 lb ASME raised face flange9) FD
Viton 1 1 4" 1500 lb ASME raised face flange9) FE
EPDM (Ethylene Propylene Rubber) 1 2 4" 2500 lb ASME raised face flange9) FF
Kalrez 4079 1 3 4" 600 lb ASME ring joint flange FG
HSN (Nitrile) 1 4 4" 900 lb ASME ring joint flange9) FH
Buna-N 1 5 4" 1500 lb ASME ring joint flange9) FJ
Neoprene 1 6 4" 2500 lb ASME ring joint flange9) FK
Chemraz 1 7 EN/DIN flanges
Polyurethane 1 8 DN 25 PN 16 EN 1092-1 Type A flat-faced flange GA
Aegis PF 128 2 1 DN 25 PN 25/40 EN 1092-1 Type A flat-faced GB
Kalrez 2035 2 2 flange
DN 25 PN 64/100 EN 1092-1 Type B1 raised-faced GC
None9) 2 3 flange
Process Connection (Size/Type) DN 25 PN 160 EN 1092-1 Type B1 raised-faced GD
Threaded flange9)
¾” NPT [(Taper), ANSI/ASME B1.20.1] AA DN 25 PN 250 EN 1092-1 Type B1 raised-faced GE
G 1" [(BSPP), EN ISO 228-1] AB flange9)
G 2" [(BSPP), EN ISO 228-1]10) AC DN 25 PN 320 EN 1092-1 Type B1 raised-faced GF
flange9)
2” NPT [(Taper), ANSI/ASME B1.20.1]10) AD
DN 25 PN 400 EN 1092-1 Type B1 raised-faced GG
ASME flanges flange9)
1" 150 lb ASME raised face flange BA
DN 40 PN 16 EN 1092-1 Type A flat-faced flange HA
1" 300 lb ASME raised face flange BB
DN 40 PN 25/40 EN 1092-1 Type A flat-faced HB
1" 600 lb ASME raised face flange BC
flange
1" 900/1500 lb ASME raised face flange9) BD DN 40 PN 64/100 EN 1092-1 Type B1 raised-faced HC
1" 2500 lb ASME raised face flange9) BE flange
1" 900/1500 lb ASME ring joint flange9) BF DN 40 PN 160 EN 1092-1 Type B1 raised-faced HD
1" 2500 lb ASME ring joint flange9) BG flange9)
1½” 150 lb ASME raised face flange CA DN 40 PN 250 EN 1092-1 Type B1 raised-faced HE
flange9)
1½” 300 lb ASME raised face flange CB

5/238 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 - SITRANS LG200 Coaxial Probes C) 7 M L 1 3 0 1 -
SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 77 7 0 SITRANS LG200 coaxial probes are used in most 77 7 7 7 - 77 7 0
standard applications. Coaxial probes yield robust standard applications. Coaxial probes yield robust
signal strength even in extremely low dielectric signal strength even in extremely low dielectric
applications (dK 1.4 to 100). applications (dK 1.4 to 100).
Note: Note:
For orders of 10 or more, please consult factory For orders of 10 or more, please consult factory
DN 40 PN 320 EN 1092-1 Type B1 raised-faced HF Further designs Order code
flange9)
Please add “-Z” to Order No. and specify Order
DN 40 PN 400 EN 1092-1 Type B1 raised-faced HG code(s).
flange9)
Enter the total insertion length in plain text descrip- Y01
DN 50 PN 16 EN 1092-1 Type A flat-faced flange JA tion, max. 610 cm (240.2”)
DN 50 PN 25/40 EN 1092-1 Type A flat-faced JB
flange Stainless steel tag. Measuring-point number/identi- Y15
fication (max. 16 characters); specify in plain text
DN 50 PN 64 EN 1092-1 Type B1 raised-faced JC Inspection Certificate Type 3.1 per EN 10204 C12
flange
Manufacturer’s test report (Hydrostatic Test) C18
DN 50 PN 100 EN 1092-1 Type B1 raised-faced JD
flange9) NACE MR-0175 materials traceability D07
DN 50 PN 160 EN 1092-1 Type B1 raised-faced JE Instruction manual
flange9)
English C) 7ML1998-5KA01
DN 50 PN 250 EN 1092-1 Type B1 raised-faced JF
flange9) German C) 7ML1998-5KA31

5
Multi-language Quick Start manual C) 7ML1998-5XG81
DN 50 PN 320 EN 1092-1 Type B1 raised-faced JG
flange9) This device is shipped with the Siemens Milltronics
DN 50 PN 400 EN 1092-1 Type B1 raised-faced JH manual CD containing the complete instruction
flange9) manual library.

DN 80 PN 16 EN 1092-1 Type A flat-faced flange KA Accessories


DN 80 PN 25/40 EN 1092-1 Type A flat-faced KB Coaxial probe shortening kit [for process tempera- C) A5E02455728
flange tures < +200 °C (+400 °F)]
DN 80 PN 64 EN 1092-1 Type B1 raised-faced KC Coaxial probe TFE spacers: pack of 10 [for process C) A5E02479058
flange tempertures < +200 °C (+400 °F)]
1)
DN 80 PN 100 EN 1092-1 Type B1 raised-faced KD Not available with O-ring option 21 (type Aegis PF128)
flange9) 2)
Consult factory for these options in Hastelloy C or Monel
3)
Available with O-ring option 23 only (none)
DN 80 PN 160 EN 1092-1 Type B1 raised-faced KE 4)
Coaxial steam probe must be used with O-ring option 21 only ( type
flange9) Aegis PF128)
DN 80 PN 250 EN 1092-1 Type B1 raised-faced KF 5)
Available with Material of Construction option A and D only [316/316L
flange9) (1.4401/1.4404) stainless steel]
6) Available with Model option 5 only (coaxial steam probe)
DN 80 PN 320 EN 1092-1 Type B1 raised-faced KG 7) 2" or DN 50 minimum Process Connection
flange9) 8)
DN 80 PN 400 EN 1092-1 Type B1 raised-faced KH Used with Model option 2 only (coaxial High Temperature/High Pressure
probe)
flange9) 9)
Available with model options 2 and 3 only (High Temperature/High Pres-
DN 100 PN 16 EN 1092-1 Type A flat-faced flange LA sure and High Pressure probes)
10)
DN 100 PN 25/40 EN 1092-1 Type A flat-faced LB Available with Material of Construction option E only (enlarged coaxial
flange probe)
DN 100 PN 64 EN 1092-1 Type B1 raised-faced LC
flange
DN 100 PN 100 EN 1092-1 Type B1 raised-faced LD
flange9)
DN 100 PN 160 EN 1092-1 Type B1 raised-faced LE
flange9)
DN 100 PN 250 EN 1092-1 Type B1 raised-faced LF
flange9)
DN 100 PN 320 EN 1092-1 Type B1 raised-faced LG
flange9)
DN 100 PN 400 EN 1092-1 Type B1 raised-faced LH
flange9)
Fisher torque tube flange, carbon steel (249B) MA
Fisher torque tube flange, 316 stainless steel MB
(249C)
Masoneilan torque tube flange, carbon steel MC
Masoneilan torque tube flange, 316 stainless steel MD

March 2009 Siemens FI 01 · 2009 US Edition 5/239


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Twin Rod Probes C) 7 M L 1 3 0 2 - SITRANS LG200 Twin Rod Probes C) 7 M L 1 3 0 2 -
SITRANS LG200 twin rod probes are used in appli- 7 7 7 7 7 - 77 7 0 SITRANS LG200 twin rod probes are used in appli- 7 7 7 7 7 - 77 7 0
cations where coating and buildup are possible. cations where coating and buildup are possible.
Used in application with dielectric constant ≥1.9. Used in application with dielectric constant ≥1.9.
Note: Note:
For orders of 10 or more, please consult factory For orders of 10 or more, please consult factory
Model Model option 1 and Material of Construction AD
Twin rod 1 option A: 301 to 400 cm (118.5 to 157.5")
Flexible twin rod bulk solids probe 2 Model option 1 and Material of Construction AE
Flexible twin rod probe 3 option A: 401 to 500 cm (157.9 to 196.9")
Model option 1 and Material of Construction AF
Material of Construction option A: 501 to 610 cm (197.2 to 240.2")
316/316L (1.4401/1.4404) stainless steel probe and A
process connection Standard lengths1)
Model option 2,3 and Material of Construction EA
Process Connection (size/type) option A: 1 meter (39.4")1)
2" NPT [(Taper), ANSI/ASME B1.20.1] A1 Model option 2,3 and Material of Construction EB
G 2" [(BSPP), EN ISO 228-1] A2 option A: 2 meters (78.7")1)
2" 150 lb ASME raised face flange A3 Model option 2,3 and Material of Construction EC
option A: 3 meters (118.1")1)
2" 300 lb ASME raised face flange B1
3" 150 lb ASME raised face flange B2 Model option 2,3 and Material of Construction ED
2” 600 lb ASME raised face flange B3 option A: 4 meters (157.5")1)
Model option 2,3 and Material of Construction EE
3" 300 lb ASME raised face flange option A: 5 meters (196.9")1)
5
C1
4" 150 lb ASME raised face flange C2 Model option 2,3 and Material of Construction EF
3" 600 lb ASME raised face flange C3 option A: 6 meters (236.2")1)
4" 300 lb ASME raised face flange D1 Model option 2,3 and Material of Construction EG
DN 50 PN 16 EN 1092-1 Type A flat-faced flange D2 option A: 7 meters (275.6")1)
4" 600 lb ASME raised face flange D3 Model option 2,3 and Material of Construction EH
option A: 8 meters (315.0")1)
DN 50 PN 25/40 EN 1092-1 Type A flat-faced E1 Model option 2,3 and Material of Construction EJ
flange option A: 9 meters (354.3")1)
DN 80 PN 16 EN 1092-1 Type A flat-faced flange E2
DN 80 PN 25/40 EN 1092-1 Type A flat-faced E3 Model option 2,3 and Material of Construction EK
flange option A: 10 meters (393.7")1)
Model option 2,3 and Material of Construction EL
DN 100 PN 16 EN 1092-1 Type A flat-faced flange E4 option A: 11 meters (433.1")1)
DN 100 PN 25/40 EN 1092-1 Type A flat-faced E5 Model option 2,3 and Material of Construction EM
flange option A: 12 meters (472.4")1)
Fisher Torque Tube flange, 316SS (249C) F1
Model option 2,3 and Material of Construction EN
Masoneilan Torque Tube flange, 316SS G1 option A: 13 meters (511.8")1)
Carbon Steel Model option 2,3 and Material of Construction EP
option A: 14 meters (551.2")1)
Fisher Torque Tube flange, Carbon Steel (249B) K1
Model option 2,3 and Material of Construction EQ
Masoneilan Torque Tube flange, Carbon Steel L1 option A: 15 meters (590.6")1)
O-Ring Model option 2,3 and Material of Construction ER
Viton 1 1 option A: 16 meters (629.9")1)
EPDM (Ethylene Propylene Rubber) 1 2 Model option 2,3 and Material of Construction ES
Kalrez 4079 1 3 option A: 17 meters (669.3")1)
HSN (Nitrile) 1 4 Model option 2,3 and Material of Construction ET
option A: 18 meters (708.7")1)
Buna-N 1 5
Neoprene 1 6 Model option 2,3 and Material of Construction EU
option A: 19 meters (748.0")1)
Chemraz 1 7
Polyurethane 1 8 Model option 2,3 and Material of Construction EV
option A: 20 meters (787.4")1)
Aegis PF 128 2 1
Model option 2,3 and Material of Construction EW
Kalrez 2035 2 2 option A: 21 meters (826.8")1)
Probe Insertion Length Model option 2,3 and Material of Construction EX
option A: 22.5 meters (885.8")1)
Add order code Y01 and plain text: “Insertion
length ... cm”
Model option 1 and Material of Construction AA
option A: 60 to 100 cm (23.6 to 39.4")
Model option 1 and Material of Construction AB
option A: 101 to 200 cm (39.8 to 78.7")
Model option 1 and Material of Construction AC
option A: 201 to 300 cm (79.1 to 118.1")

5/240 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No.


SITRANS LG200 Twin Rod Probes C) 7 M L 1 3 0 2 -
SITRANS LG200 twin rod probes are used in appli- 7 7 7 7 7 - 77 7 0
cations where coating and buildup are possible.
Used in application with dielectric constant ≥1.9.
Note:
For orders of 10 or more, please consult factory
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Enter the total insertion length in plain text descrip- Y01
tion, max. 610 cm (240.2”) (Not needed for stan-
dard lengths, insertion length options EA to EX)
Stainless steel tag. Measuring-point number/identi- Y15
fication (max. 16 characters); specify in plain text
Inspection Certificate Type 3.1 per EN 10204 C12
2)
Manufacturer’s test report (Hydrostatic Test) C18

NACE MR-0175 materials traceability2) D07


Instruction manual
English C) 7ML1998-5KA01
German C) 7ML1998-5KA31
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
C) 7ML1998-5XG81
5
manual CD containing the complete instruction
manual library.
1)
No Y01 needed in order code
2)
Available with Model option 1 only
C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/241


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Single Rod Rigid Probes C) 7 M L 1 3 0 3 - SITRANS LG200 Single Rod Rigid Probes C) 7 M L 1 3 0 3 -
SITRANS LG200 single rod rigid probes are used in 7 7 7 7 7 - 77 7 0 SITRANS LG200 single rod rigid probes are used in 7 7 7 7 7 - 77 7 0
applications where coating and buildup are likely. applications where coating and buildup are likely.
Used in applications with dielectric constant ≥10, or Used in applications with dielectric constant ≥10, or
dk >1.9 when installed within 2 to 6" of a metal tank dk >1.9 when installed within 2 to 6" of a metal tank
wall or in cage or bridle. wall or in cage or bridle.
Note: Note:
For orders of 10 or more, please consult factory For orders of 10 or more, please consult factory
Model DN 80, PN 16, EN 1092-1 Type A flat-faced L3
Single rod rigid probe1) 1 flange11)
High Temperature/High Pressure Single rod2) 3) 2 DN 80, PN 25/40, EN 1092-1 Type A flat-faced L4
flange11)
Material of Construction
316/316L (1.4401/1.4404) stainless steel probe and A DN 100, PN 16, EN 1092-1 Type A flat-faced L5
process connection flange11)
316/316L (1.4401/1.4404) stainless steel sanitary D DN 100, PN 25/40, EN 1092-1 Type A flat-faced L6
probe and process connection1) 4) flange11)
PFA faced-flange and rod insulation, all PFA wetted E Higher Pressure rated flanges
parts (316 SS rod)1) 5) ANSI/ASME
316 AL6XN stainless steel sanitary probe and pro- F
cess connection1) 6) 2" 600 lb ASME raised face flange8) M0
PFA rod insulation (316 SS rod and process con- J 2" 900/1500 lb ASME raised face flange12) M1
nection) 2" 2500 lb ASME raised face flange12) M2

5 Process Connection (size/type)


1 or 1½" Tri-Clover 16 amp sanitary fitting7) A1
3" 600 lb ASME raised face flange8)
3" 900 lb ASME raised face flange12)
N0
N3
2" NPT [(Taper), ANSI/ASME B1.20.1]8) A2 3" 1500 lb ASME raised face flange12) N4
G 2" [(BSPP), EN ISO 228-1]8) A3 3" 2500 lb ASME raised face flange12) N5
2" 150 lb ASME raised face flange8) A4 4" 600 lb ASME raised face flange8) P 0
2" 300 lb ASME raised face flange8) A5 4" 900 lb ASME raised face flange12) P 3
4" 1500 lb ASME raised face flange12) P 4
2" Tri-Clover 16 amp sanitary fitting7) A6
4" 2500 lb ASME raised face flange12) P 5
¾" Tri-Clover 16 amp sanitary fitting7) 9) A7
2½" Tri-Clover 16 amp sanitary fitting7) B0 2" 600 lb ASME ring type joint flange8) Q0
2" 900/1500 lb ASME ring type joint flange12) Q1
3" 150 lb ASME raised face flange8) B1
2" 2500 lb ASME ring type joint flange12) Q2
3" 300 lb ASME raised face flange8) B2
3" 600 lb ASME ring type joint flange8) R0
3" Tri-Clover 16 amp sanitary fitting7) B3
3" 900 lb ASME ring type joint flange12) R3
4" 150 lb ASME raised face flange8) C1
3" 1500 lb ASME ring type joint flange12) R4
4" 300 lb ASME raised face flange8) C2 3" 2500 lb ASME ring type joint flange12) R5
4" Tri-Clover 16 amp sanitary fitting7) C3
4" 600 lb ASME ring type joint flange8) S 0
DN 50, PN 16, EN 1092-1 Type A flat-faced flange8) D1
4" 900 lb ASME ring type joint flange12) S 3
DN 50, PN 25/40, EN 1092-1 Type A flat-faced D2 4" 1500 lb ASME ring type joint flange12) S 4
flange8) 4" 2500 lb ASME ring type joint flange12) S 5
DN 80, PN 16, EN 1092-1 Type A flat-faced flange8) D3
EN/DIN
DN 80, PN 25/40, EN 1092-1 Type A flat-faced D4
flange8) DN 50, PN 64, EN 1092-1 Type A flat-faced flange8) T0
DN 100, PN 16, EN 1092-1 Type A flat-faced D5 DN 50, PN 100, EN 1092-1 Type A flat-faced flange8) T1
flange8) DN 50, PN 160, EN 1092-1 Type A flat-faced flange12) T2
DN 100, PN 25/40, EN 1092-1 Type A flat-faced D6 DN 50, PN 250, EN 1092-1 Type A flat-faced flange12) T3
flange8)
DN 80, PN 64, EN 1092-1 Type A flat-faced flange8) U0
AL6XN10) DN 80, PN 100, EN 1092-1 Type A flat-faced flange8) U1
¾” Tri-Clover 16 amp sanitary fitting9) 10) E0
DN 80, PN 160, EN 1092-1 Type A flat-faced flange12) U2
1½” Tri-Clover 16 amp sanitary fitting10) E1
DN 80, PN 250, EN 1092-1 Type A flat-faced flange12) U3
2" Tri-Clover 16 amp sanitary fitting10) E2
DN 100, PN 64, EN 1092-1 Type A flat-faced flange8) V0
2½” Tri-Clover 16 amp sanitary fitting10) E3
DN 100, PN 100, EN 1092-1 Type A flat-faced lange8) V1
3" Tri-Clover 16 amp sanitary fitting10) F1
DN 100, PN 160, EN 1092-1 Type A flat-faced V2
4" Tri-Clover 16 amp sanitary fitting10) G1 flange12)
PFA Coated 316 stainless steel flange11) DN 100, PN 250, EN 1092-1 Type A flat-faced V3
2" 150 lb ASME raised face flange11) H1 flange12)
2" 300 lb ASME raised face flange11) H2 O-Ring
3" 150 lb ASME raised face flange11) J1 Viton 1 1
3" 300 lb ASME raised face flange11) J2 EPDM (Ethylene Propylene Rubber) 1 2
Kalrez 4079 1 3
4" 150 lb ASME raised face flange11) K1
4" 300 lb ASME raised face flange11) K2 HSN (Nitrile) 1 4
Buna-N 1 5
DN 50, PN 16, EN 1092-1 Type A flat-faced L1
flange11) Neoprene 1 6
DN 50, PN 25/40, EN 1092-1 Type A flat-faced L2 Chemraz 1 7
flange11) Polyurethane 1 8

5/242 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Single Rod Rigid Probes C) 7 M L 1 3 0 3 - SITRANS LG200 Single Rod Rigid Probes C) 7 M L 1 3 0 3 -
SITRANS LG200 single rod rigid probes are used in 7 7 7 7 7 - 77 7 0 SITRANS LG200 single rod rigid probes are used in 7 7 7 7 7 - 77 7 0
applications where coating and buildup are likely. applications where coating and buildup are likely.
Used in applications with dielectric constant ≥10, or Used in applications with dielectric constant ≥10, or
dk >1.9 when installed within 2 to 6" of a metal tank dk >1.9 when installed within 2 to 6" of a metal tank
wall or in cage or bridle. wall or in cage or bridle.
Note: Note:
For orders of 10 or more, please consult factory For orders of 10 or more, please consult factory
Aegis PF 128 2 1 Add order code Y01 and plain text: “Insertion
Kalrez 2035 2 2 length ... cm”
None3) 2 3 Model option 1 and Material of Construction EA
option J: 60 to 100 cm (23.6 to 39.4")
Probe Insertion Length Model option 1 and Material of Construction EB
Add order code Y01 and plain text: “Insertion option J: 101 to 200 cm (39.8 to 78.7")
length ... cm” Model option 1 and Material of Construction EC
Model option 1, 2 and Material of Construction AA option J: 201 to 300 cm (79.1 to 118.1")
option A: 60 to 100 cm (23.6 to 39.4")
Model option 1, 2 and Material of Construction AB Model option 1 and Material of Construction ED
option A: 101 to 200 cm (39.8 to 78.7") option J: 301 to 400 cm (118.5 to 157.5")
Model option 1, 2 and Material of Construction AC Model option 1 and Material of Construction EE
option A: 201 to 300 cm (79.1 to 118.1") option J: 401 to 500 cm (157.9 to 196.9")
Model option 1 and Material of Construction EF
Model option 1, 2 and Material of Construction AD option J: 501 to 610 cm (197.2 to 240.2")
option A: 301 to 400 cm (118.5 to 157.5")
Add order code Y01 and plain text: “Insertion
Model option 1, 2 and Material of Construction
option A: 401 to 500 cm (157.9 to 196.9")
AE
length ... cm” (¾” Process Connection only)
Model option 1 and Material of Construction FA
5
Model option 1, 2 and Material of Construction AF
option A: 501 to 610 cm (197.2 to 240.2") option D and F: 60 to 100 cm (23.6 to 39.4")13)
Add order code Y01 and plain text: “Insertion Model option 1 and Material of Construction FB
length ... cm” option D and F: 101 to 180 cm (39.8 to 72")13)
Model option 1 and Material of Construction BA Further designs Order code
option D: 60 to 100 cm (23.6 to 39.4")
Please add “-Z” to Order No. and specify Order
Model option 1 and Material of Construction BB code(s).
option D: 101 to 200 cm (39.8 to 78.7")
Model option 1 and Material of Construction BC Enter the total insertion length in plain text descrip- Y01
option D: 201 to 300 cm (79.1 to 118.1") tion, max. 610 cm (240.2”)
Model option 1 and Material of Construction BD Stainless steel tag. Measuring-point number/identi- Y15
option D: 301 to 400 cm (118.5 to 157.5") fication (max. 16 characters); specify in plain text
Model option 1 and Material of Construction BE Inspection Certificate Type 3.1 per EN 10204 C12
option D: 401 to 500 cm (157.9 to 196.9") Manufacturer’s test report (Hydrostatic Test) C18
Model option 1 and Material of Construction BF
option D: 501 to 610 cm (197.2 to 240.2") NACE MR-0175 materials traceability D07
Add order code Y01 and plain text: “Insertion Instruction manual
length ... cm”
English C) 7ML1998-5KA01
Model option 1 and Material of Construction CA
option F: 60 to 100 cm (23.6 to 39.4") German C) 7ML1998-5KA31

Model option 1 and Material of Construction CB Multi-language Quick Start manual C) 7ML1998-5XG81
option F: 101 to 200 cm (39.8 to 78.7") This device is shipped with the Siemens Milltronics
Model option 1 and Material of Construction CC manual CD containing the complete instruction
option F: 201 to 300 cm (79.1 to 118.1") manual library.
Model option 1 and Material of Construction CD Accessories
option F: 301 to 400 cm (118.5 to 157.5") TFE bottom spacer/endplate C) 7ML1930-1DJ
Model option 1 and Material of Construction CE
1)
option F: 401 to 500 cm (157.9 to 196.9") Model option 1 with Material of Construction options D, E, F, available with
Model option 1 and Material of Construction CF O-ring option 2 3 only
2)
option F: 501 to 610 cm (197.2 to 240.2") Available with O-ring option 2 1 only
3)
Add order code Y01 and plain text: “Insertion Available with Material of Construction option A only
4)
length ... cm” Available with Process Connection options A1, A6, A7, B0, B3, C3 only
5)
Available with Process Connection options H1, H2, J1, J2, K1, K2, L1, L2,
Model option 1 and Material of Construction DA L3, L4, L5, L6 only.
option E: 60 to 100 cm (23.6 to 39.4") 6)
Available with Process Connection options E0, E1, E2, E3, F1, G1 only
Model option 1 and Material of Construction DB 7)
Available with Material of Construction option D only
option E: 101 to 200 cm (39.8 to 78.7") 8) Available with Material of Construction options A and J only
Model option 1 and Material of Construction DC 9) Available with Probe Insertion Length options FA and FB only
option E: 201 to 300 cm (79.1 to 118.1") 10)
Available with Material of Construction option F only
11)
Model option 1 and Material of Construction DD Available with Material of Construction option E only
12)
option E: 301 to 400 cm (118.5 to 157.5") Available with Model option 2 only
13)
Model option 1 and Material of Construction DE Available with Process Connection options A7 and E0 only (¾”)
option E: 401 to 500 cm (157.9 to 196.9") C) Subject to export regulations AL: N, ECCN: EAR99
Model option 1 and Material of Construction DF
option E: 501 to 610 cm (197.2 to 240.2")

March 2009 Siemens FI 01 · 2009 US Edition 5/243


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LG200 Single Rod Flexible Probes C) 7 M L 1 3 0 4 - SITRANS LG200 Single Rod Flexible Probes C) 7 M L 1 3 0 4 -
SITRANS LG200 single rod flexible probes are 7 7 7 7 7 - 77 7 0 SITRANS LG200 single rod flexible probes are 7 7 7 7 7 - 77 7 0
used in applications where coating and buildup are used in applications where coating and buildup are
possible. Used in applications with dielectric con- possible. Used in applications with dielectric con-
stant ≥10 or dk >1.9 when installed within 2 to 6” of stant ≥10 or dk >1.9 when installed within 2 to 6” of
a metal tank wall or in cage or bridle. For solids ver- a metal tank wall or in cage or bridle. For solids ver-
sion only, dk>4. sion only, dk>4.
Note: Note:
For orders of 10 or more, please consult factory For orders of 10 or more, please consult factory
Model 19 meters (748.0") AU
Single rod flexible probe 1 20 meters (787.4") AV
Single rod bulk solids flexible probe1) 2 21 meters (826.8") AW
Material of Construction 22.5 meters (885.8") AX
316/316L (1.4401/1.4404) stainless steel probe and A Further designs Order code
process connection
Please add “-Z” to Order No. and specify Order
Process Connection (size/type) code(s).
316/316L (1.4401/1.4404)
2" NPT [(Taper), ANSI/ASME B1.20.1] A0 Stainless steel tag. Measuring-point number/identi- Y15
fication (max. 16 characters); specify in plain text
G 2" [(BSPP), EN ISO 228-1] A1
2" 150 lb ASME raised face flange A2 Instruction manual
2" 300 lb ASME raised face flange A3 English C) 7ML1998-5KA01
German C) 7ML1998-5KA31
3" 150 lb ASME raised face flange B1
Multi-language Quick Start manual C) 7ML1998-5XG81

5 3" 300 lb ASME raised face flange


4" 150 lb ASME raised face flange
B2
C1
This device is shipped with the Siemens Milltronics
manual CD containing the complete instruction
4" 300 lb ASME raised face flange C2 manual library.
DN 50 PN 16 EN 1092-1 Type A flat-faced flange D1 1)
DN 50 PN 25/40 EN 1092-1 Type A flat-faced D2 Available with O-ring option 1 1 only (others on request)
flange C) Subject to export regulations AL: N, ECCN: EAR99
DN 80 PN 16 EN 1092-1 Type A flat-faced flange E1
DN 80 PN 25/40 EN 1092-1 Type A flat-faced E2
flange
DN 100 PN 16 EN 1092-1 Type A flat-faced flange F1
DN 100 PN 25/40 EN 1092-1 Type A flat-faced F2
flange
O-Ring
Viton 1 1
EPDM (Ethylene Propylene Rubber) 1 2
Kalrez 4079 1 3
HSN (Nitrile) 1 4
Buna-N 1 5
Neoprene 1 6
Chemraz 1 7
Polyurethane 1 8
Aegis PF 128 2 1
Kalrez 2035 2 2
Flexible Rod Length (To be shortened by
customer as required)
1 meter (39.4") AA
2 meters (78.7") AB
3 meters (118.1") AC
4 meters (157.5") AD
5 meters (196.9") AE
6 meters (236.2") AF
7 meters (275.6") AG
8 meters (315.0) AH
9 meters (354.3") AJ
10 meters (393.7") AK
11 meters (433.1") AL
12 meters (472.4") AM
13 meters (511.8") AN
14 meters (551.2") AP
15 meters (590.6") AQ
16 meters (629.9") AR
17 meters (669.3") AS
18 meters (708.7") AT

5/244 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

Selection and Ordering data Order No.


SITRANS LG200 Chamber Replacement Probe C) 7 M L 1 3 0 5 -
SITRANS LG200 Chamber Replacement Probe 7 7 7 7 7 - 77 7 0
replaces existing aging torque tube transmitters.
Proprietary flanges can be used with existing
chambers and cages.
Note:
For this option, please consult factory
Model
Chamber Replacement Probe1) 1
Chamber/Process Connection Material of
Construction
316/316L stainless steel (B31.1 construction) A
Carbon Steel (106 Grade B)2) B
Carbon Steel (B31.1 construction) C
Process Connection (size/type)
1½” NPT [(Taper), ANSI/ASME B1.20.1] thread A0
1½”, 150 lb ASME raised face flange A1
1½”, 300 lb ASME raised face flange A2
1½”, 600 lb ASME raised face flange A3
1½” Socket weld B1
2" NPT [(Taper), ANSI/ASME B1.20.1] thread B2
2", 150 lb ASME raised face flange
2", 300 lb ASME raised face flange
C1
C2
5
2", 600 lb ASME raised face flange D1
2" Socket weld D2
Other flange sizes available. Please consult factory.
Level Range
14" (0.356 meters) 1
Other level ranges available. Please consult
factory.
Process Connection Configuration
Top In, Bottom Out 1
Top In, Bottom Out, with Sight Glass Connections 2
Other configurations available. Please consult
factory.
Temperature Range
+316 °C (+600 °F) (Dielectric constant ≥10) A
+260 °C (+500 °F) (Dielectric constant ≥1.4) B
Chamber Type
Fisher 249B A
Fisher 259B B
Fisher 249 C
Further designs Order code
Please add “-Z” to Order No. and specify Order
code(s).
Stainless steel tag. Measuring-point number/identi- Y15
fication (max. 16 characters); specify in plain text
Inspection Certificate Type 3.1 per EN 10204 C12

NACE MR-0175 materials traceability D07


Instruction manual
English C) 7ML1998-5KA01
German C) 7ML1998-5KA31
Multi-language Quick Start manual C) 7ML1998-5XG81

This device is shipped with the Siemens Milltronics


manual CD containing the complete instruction
manual library.
1)
Probe is always 316/316L (1.4401/1.4404) Stainless Steel construction
regardless of chamber and process connection materials.
2)
Available Process Connection Configuration option 1 only
C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/245


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

■ Characteristic curves (examples for threaded process connections only)

SITRANS LG200 Process Pressure/Temperature derating curves

5/246 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

■ Characteristic curves (examples for threaded process connections only)

SITRANS LG200 Process Pressure/Temperature derating curves

March 2009 Siemens FI 01 · 2009 US Edition 5/247


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

■ Dimensional drawings

SITRANS LG200 dimensions (threaded process connection dimensions shown are NPT connections unless stated otherwise)

5/248 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

SITRANS LG200 dimensions (threaded process connection dimensions shown are NPT connections unless stated otherwise)

March 2009 Siemens FI 01 · 2009 US Edition 5/249


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

SITRANS LG200 dimensions (threaded process connection dimensions shown are NPT connections unless stated otherwise)

5/250 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

SITRANS LG200 - Model 7ML1305-1 Chamber Replacement Probe

March 2009 Siemens FI 01 · 2009 US Edition 5/251


© Siemens AG 2009

Level instruments
Continuous level measurement - Guided wave radar transmitters
SITRANS LG200

■ Schematics

SITRANS LG200 connections

5/252 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

■ Overview ■ Configuration

SITRANS LC300 is an inverse frequency shift capacitance con-


tinuous level transmitter for liquids and solids applications. It is
ideal for standard industrial applications in chemical, hydrocar-
bon processing, food and beverage and mining, aggregate and
cement industries. 5
■ Benefits
• Patented Active-Shield technology so measurement is unaf-
fected by material buildup in active shield section
• Highly accurate and reliable PFA-lined probes
• Integrated local LCD display
• 2-wire (4 to 20 mA) current loop design
• Current signalling according to NAMUR NE 43
• Push-button calibration and programming SITRANS LC300 installation

■ Application
SITRANS LC300 is a 2-wire level measurement instrument com-
bining a sophisticated, yet easy-to-adjust microprocessor with
field-proven probes. It is available in two versions: rod and ca-
ble.
SITRANS LC300 has a stainless steel process connection with
PFA-lined probe. Materials with low or high dielectric properties
are accurately measured and patented Active-Shield technol-
ogy helps in ignoring the effects of buildup near vessel nozzle.
• Key Applications: Conductive and non-conductive media in-
cluding liquids and solids in standard industrial processes
and bulk solids applications involving dust or chemical pro-
cesses involving vapour

March 2009 Siemens FI 01 · 2009 US Edition 5/253


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

■ Technical specifications Power supply 12 to 30 V DC any polarity, 2-wire


current loop circuit
Input User Interface
Measuring range 1.66 to 3300 pF Display Local LCD, 4 digit, each 0 to 9
Span Min. 3.3 pF and limited alpha characters
Output Safety
Loop current Continuous signal 4 to 20 mA/20 Measurement current signalling According to NAMUR NE 43, sig-
to 4 mA according to NAMUR 43 nal 3.8 to 20.5 mA, fault ≤ 3.6 or
≥ 21 mA (22 mA)
Accuracy (transmitter)
Certificates and approvals
Temperature stability 0.25% of actual capacitance
value • General CE, CSA, FM
Non-linearity and repeatability < 0.4% of full scale and actual • Dust Ignition Proof • CSA/FM Class II, III, Div 1,
measurement value (Intrinsically Safe probe circuit) Groups E, F, G T4
Accuracy Deviation < 0.5% of actual mea- • ATEX II 1/2 D T100 °C
surement value • Explosion Proof • CSA/FM Class I, Div 1, Groups
Rated operating conditions1) (Intrinsically Safe probe circuit) A, B, C, D T4
• ATEX II 1/2 G EEx d [ia] IIC T6 to
Ambient conditions T1
• Ambient temperature (transmitter) -40 to +85 °C (-40 to +185 °F) • Marine Lloyds Register of Shipping, cate-
• Installation category II gories ENV1, ENV2, ENV3 and
ENV5, American Bureau of Ship-
• Pollution degree 4 ping (ABS)
5 • Ingress protection Type 4/NEMA 4/IP65 (optional
IP68)
• Pressure PED 97/23/EC, CSA B51
• Other C-TICK (Australia)
Installation conditions
1)
When operation is in areas classified as hazardous, observe restrictions
• Location Indoor/outdoor according to relevant certificate. See also Pressure/Temperature curves on
Pressure range -1 to 35 bar g (-14.6 to 511 psi g) page 5/257.

Process temperature (probe) -40 to +200 ºC (-40 to +392 ºF) Consider diameter of cable weight (34.5 mm/1.36") when choosing Pro-
cess Connection.
Min. dielectric constant εr 1.5
Design: Probe
Design
Standard version Cable version
Material
Length Min. 300 mm (12"), Min. 1000 mm (40"),
• Enclosure Aluminum, epoxy-coated
max. 5000 mm (197") max. 25000 mm (984")
Probe diameter
Sensor wetted parts PFA, 316L stainless 316 stainless steel,
• Rod version 19 mm (0.75") with PFA jacket steel optional PFA
• Cable version 9 mm (0.35") with PFA jacket, 6 O-ring seal material1) FKM FKM
mm (0.24") without PFA jacket
Thermal isolator Optional Optional
Active shield length 1)
FFKM available as special option. Contact nacc.smpi@siemens.com for
• Rod version 100 mm (3.94") details.
• Cable version 105 mm (4.13")
Process connection of probe
• Threaded rod mounting ¾",1",1¼", 1½" NPT [(Taper),
ANSI/ASME B1.20.1]
R ¾",1",1¼", 1½" [(BSPT), EN
10226/PT (JIS-T), JIS B 0203]
G ¾",1", 1½" [(BSPP), EN ISO
228-1/PF (JIS-P), JIS B 0202]
• Threaded cable mounting 1½" NPT [(Taper), ANSI/ASME
B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-
T), JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202]
• Flange mounting 1 to 4" ASME, DIN DN 25 to 100
Enclosure cable inlet 2 x ½" NPT or 2 x M20x1.5

5/254 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC300, threaded 7ML 5 6 2 5 - SITRANS LC300, threaded 7ML 5 6 2 5 -
An inverse frequency shift capacitance continuous 7 7 7 77 - 77 A 7 An inverse frequency shift capacitance continuous 7 7 7 77 - 77 A 7
level transmitter for liquids and solids applications. level transmitter for liquids and solids applications.
Version Enclosure
(threaded lengths include process thread) Aluminum, epoxy-coated
Rod, 19 mm (0.75") diameter, PFA insulated Cable entry 2 x ½" NPT, IP65 0
Add order code Y01 and plain text: “Insertion Cable entry 2 x M20x1.5, IP65 1
length ... mm"
- 300 to 1000 mm (11.81 to 39.37") 0A Cable entry 2 x ½" NPT, IP68 2
- 1001 to 2000 mm (39.41 to 78.74") 1A Cable entry 2 x M20x1.5, IP68 3
- 2001 to 3000 mm (78.78 to 118.11")1) 2A Thermal isolator/remote version
- 3001 to 4000 mm (118.15 to 157.48")1) 3A None A
With thermal isolator B
- 4001 to 5000 mm (157.52 to 196.85")1) 4A
Rod, 19 mm (0.75") diameter, PFA insulated with With mounting eye4) C
35 mm (1.38") diameter stilling well With thermal isolator and mounting eye4) D
Add order code Y01 and plain text: “Insertion
length ... mm" Electronic transmitter
- 300 to 1000 mm (11.81 to 39.37")2) 0B 3300 pF range 1
- 1001 to 2000 mm (39.41 to 78.74")2) 1B Further designs Order code
- 2001 to 3000 mm (78.78 to 118.11")1) 2) 2B Please add “-Z" to Order No. and specify Order
code(s).
- 3001 to 4000 mm (118.15 to 157.48")1) 2) 3B
- 4001 to 5000 mm (157.52 to 196.85")1) 2) 4B Insertion length, specify in plain text: Y01
Cable, 9 mm (0.75") diameter, PFA insulated,
weighted
Y01: ... mm
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15 5
Add order code Y01 and plain text: “Insertion Measuring-point number/identification (max. 16
length ... mm" characters); specify in plain text
- 1000 to 2000 mm (39.37 to 78.74")2) 0E Acceptance test certificate: Manufacturer's test C11
- 2001 to 4000 mm (78.78 to 157.48")2) 1E certificate M to DIN 55350, Part 18 and ISO 9000
- 4001 to 6000 mm (157.52 to 236.22")2) 2E Inspection Certificate Type 3.1 per EN 10204 C12
- 6001 to 8000 mm (236.26 to 314.96")2) 3E Instruction manual Order No.
- 8001 to 10000 mm (315 to 393.70")2) 4E English 7ML1998-5HE01
Cable, 6 mm (0.24") diameter, non-insulated, French 7ML1998-5HE11
weighted
German 7ML1998-5HE31
Add order code Y01 and plain text: “Insertion
length ... mm" Spanish 7ML1998-5HE21
Note: The instruction manual should be ordered as
- 1000 to 2000 mm (39.37 to 78.74")2) 0F
a separate line item on the order.
- 2001 to 4000 mm (78.78 to 157.48")2) 1F
- 4001 to 6000 mm (157.52 to 236.22")2) 2F This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
- 6001 to 8000 mm (236.26 to 314.96")2) 3F Start and instruction manual library.
- 8001 to 10000 mm (315 to 393.70")2) 4F Accessories
- Cable lengths up to 25000 mm (984.25") are
possible for non-conductive media. Cable ½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA
lengths up to 15000 mm (590.55") are possible diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 °C
for conductive media. Contact nacc.smpi@sie- (-40 to +212 °F), IP68 (General Purpose)
mens.com for details. ½" NPT cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JB
and EEx e II, fits cable diameter 6.5 to 14 mm (0.26
Process connection to 0.55"), -60 to +130 °C (-76 to +266 °F), IP68
¾" NPT [(Taper), ANSI/ASME B1.20.1]3) A0 (Explosion Proof)
1" NPT [(Taper), ANSI/ASME B1.20.1]3) B0 M20x1.5 cable gland, PA polyamide, ATEX II 2G 7ML1830-1JC
1½" NPT [(Taper), ANSI/ASME B1.20.1] C0 EEx e II, fits cable diameter 7 to 12 mm (0.28 to
0.47"), -20 to +70 °C (-4 to +158 °F), IP68
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]3) D0 (General Purpose)
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]3) E0
M20x1.5 cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JD
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F0 and EEx e II, fits cable diameter 10.5 to 15.9 mm
1¼" NPT [(Taper), ANSI/ASME B1.20.1] K0 (0.41 to 0.63"), under armour cable diameter 6.1 to
11.5 mm (0.24 to 0.45"), -60 to +130 °C (-76 to
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B L0 +266 °F), IP68 (Explosion Proof)
0202]3)
Electronic transmitter kit (includes transmitter and C) 7ML1830-1KN
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B M0 driver)
0202]3)
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B N0 Spare parts
0202] Amplifier/Power Supply C) 7ML1830-1DJ
Approvals 1)
Custom shipping methods required. Contact factory for more details
General purpose 1 2)
For process connections 1½" and larger
CSA and FM Class II and III, Div. 1, Groups E, F, G 2 3) Available for rod versions only
T4; ATEX II 1/2 D T100 °C 4)
Available for PFA insulated cable versions 0E to 4E only
ATEX II 1/2 G EEx d [ia] IIC T6 to T1 3
C) Subject to export regulations AL: N, ECCN: EAR99
CSA/FM Class I, Div. 1, Groups A, B, C, D T4 4 F) Subject to export regulations AL: 9I999, ECCN: N

March 2009 Siemens FI 01 · 2009 US Edition 5/255


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC300, welded flange 7ML 5 6 2 6 - SITRANS LC300, welded flange 7ML 5 6 2 6 -
An inverse frequency shift capacitance continuous 7 7 7 77 - 77 A 7 An inverse frequency shift capacitance continuous 7 7 7 77 - 77 A 7
level transmitter for liquids and solids applications. level transmitter for liquids and solids applications.
Version Approvals
(lengths from flange face) General purpose 1
Rod, PFA insulated CSA/FM Class II and III, Div. 1, Groups E, F, G T4; 2
Add order code Y01 and plain text: “Insertion ATEX II 1/2 D T100 °C
length ... mm" ATEX II 1/2 G EEx d [ia] IIC T6 to T1 3
- 300 to 1000 mm (11.81 to 39.37") 0A
- 1001 to 2000 mm (39.41 to 78.74") 1A CSA/FM Class I, Div. 1, Groups A, B, C, D T4 4
- 2001 to 3000 mm (78.78 to 118.11")1) 2A Enclosure
- 3001 to 4000 mm 118.15 to 157.48")1) 3A Aluminum, epoxy-coated
- 4001 to 5000 mm (157.52 to 196.85")1) 4A • Cable entry 2 x ½" NPT, IP65 0
Rod, PFA insulated with stilling well • Cable entry 2 x M20x1.5, IP65 1
Add order code Y01 and plain text: “Insertion • Cable entry 2 x ½" NPT, IP68 2
length ... mm" • Cable entry 2 x M20x1.5, IP68 3
- 300 to 1000 mm (11.81 to 39.37")2) 0B
Thermal isolator/remote version
- 1001 to 2000 mm (39.41 to 78.74")2) 1B
None A
- 2001 to 3000 mm (78.78 to 118.11")1) 2) 2B
With thermal isolator B
- 3001 to 4000 mm (118.15 to 157.48")1) 2) 3B
With mounting eye4) C
- 4001 to 5000 mm (157.52 to 196.85")1) 2) 4B
With thermal isolator and mounting eye4) D
Cable, PFA insulated, weighted
Add order code Y01 and plain text: “Insertion Electronic transmitter
length ... mm" 3300 pF range 1
- 1000 to 2000 mm (39.37 to 78.74")2) 0E
5 - 2001 to 4000 mm (78.78 to 157.48")2)
- 4001 to 6000 mm (157.52 to 236.22")2)
1E
2E
Further designs
Please add “-Z" to Order No. and specify Order
Order code

code(s).
- 6001 to 8000 mm (236.26 to 314.96")2) 3E
- 8001 to 10000 mm (315 to 393.70")2) 4E Insertion length, specify in plain text: Y01
Cable, non-insulated, weighted Y01: ... mm
Add order code Y01 and plain text: “Insertion Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
length ... mm" Measuring-point number/identification (max. 16
- 1000 to 2000 mm (39.37 to 78.74")2) 0F characters); specify in plain text
- 2001 to 4000 mm (78.78 to 157.48")2) 1F Acceptance test certificate: Manufacturer's test C11
- 4001 to 6000 mm (157.52 to 236.22")2) 2F certificate M to DIN 55350, Part 18 and ISO 9000
- 6001 to 8000 mm (236.26 to 314.96")2) 3F Inspection Certificate Type 3.1 per EN 10204 C12
- 8001 to 10000 mm (315 to 393.70")2) 4F
- Cable lengths up to 25000 mm (984.25") are Instruction manual Order No.
possible for non-conductive media. Cable English 7ML1998-5HE01
lengths up to 15000 mm (590.55") are possible French 7ML1998-5HE11
for conductive media. Contact nacc.smpi@sie- German 7ML1998-5HE31
mens.com for details. Spanish 7ML1998-5HE21
Process connection Note: The instruction manual should be ordered as
a separate line item on the order.
Welded flange, 316L stainless steel, raised face
1" ASME 150 lb3) A1 This device is shipped with the Siemens Milltronics
1" ASME 300 lb3) A2 manual CD containing the complete ATEX Quick
1" ASME 600 lb3) A3 Start and instruction manual library.
1½" ASME 150 lb B1 Accessories
1½" ASME 300 lb B2 ½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA
diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 °C
1½" ASME 600 lb B3 (-40 to +212 °F), IP68 (General Purpose)
2" ASME 150 lb C1 ½" NPT cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JB
2" ASME 300 lb C2 and EEx e II, fits cable diameter 6.5 to 14 mm (0.26
2" ASME 600 lb C3 to 0.55"), -60 to +130 °C (-76 to +266 °F), IP68
(Explosion Proof)
3" ASME 150 lb D1 M20x1.5 cable gland, PA polyamide, ATEX II 2G 7ML1830-1JC
3" ASME 300 lb1) D2 EEx e II, fits cable diameter 7 to 12 mm (0.28 to
3" ASME 600 lb1) D3 0.47"), -20 to +70 °C (-4 to +158 °F), IP68
4" ASME 150 lb1) E1 (General Purpose)
4" ASME 300 lb1) E2 M20x1.5 cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JD
4" ASME 600 lb1) E3 and EEx e II, fits cable diameter 10.5 to 15.9 mm
Welded flange, 316L stainless steel, Type A flat (0.41 to 0.63"), under armour cable diameter 6.1 to
faced 11.5 mm (0.24 to 0.45"), -60 to +130 °C (-76 to
+266 °F), IP68 (Explosion Proof)
DN 25, PN 163) J4
DN 25, PN 403) J6 Electronic transmitter kit (includes transmitter and C) 7ML1830-1KN
driver)
DN 40, PN 16 K4
Spare parts
DN 40, PN 40 K6
Amplifier/Power Supply C) 7ML1830-1DJ
DN 50, PN 16 L4
DN 50, PN 40 L6 1)
Custom shipping methods required. Contact factory for more details
2)
DN 80, PN 16 M4 For process connections 1½" and larger
3)
DN 80, PN 401) M6 Only for use with Versions 0A to 4A
4) Available for PFA insulated cable versions 0E to 4E only
DN 100, PN 161) N4
DN 100, PN 401) N6 C) Subject to export regulations AL: N, ECCN: EAR99
(Note: Flange bolting patterns and facings dimen- F) Subject to export regulations AL: 9I999, ECCN: N
sionally correspond to the applicable ASME B16.5,
or EN 1092-1 standard.)

5/256 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

■ Characteristic curves

SITRANS LC300 Process Pressure/Temperature derating curves (7ML5625)

March 2009 Siemens FI 01 · 2009 US Edition 5/257


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626)

SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626)

5/258 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

■ Dimensional drawings

SITRANS LC300 dimensions - Threaded Process Connections

March 2009 Siemens FI 01 · 2009 US Edition 5/259


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

SITRANS LC300 dimensions - Flanged Process Connections

5/260 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300

■ Schematics

SITRANS LC300 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/261


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

■ Overview ■ Configuration

5
SITRANS LC500 is an inverse frequency shift capacitance level
or interface transmitter for extreme and critical process condi-
tions, such as oil and liquified natural gas (LNG) as well as toxic
and aggressive chemicals and vapours.

■ Benefits
• Patented Active-Shield technology so measurement is unaf-
fected by material buildup in active shield section
SITRANS LC500 installation
• Simple push-button calibration and integrated local display
• Inverse frequency approach provides high resolution
• 2-wire loop powered 4 to 20/20 to 4 mA measurement signal
• Pre-detection alarm and full function diagnostics
■ Technical specifications
• High temperature and pressure resistant (optional) Input
• Full-function diagnostics comply with NAMUR NE 43 Measuring range 1 to 3300 pF
• Easy calibration locally or via HART (using SIMATIC PDM soft- Span Min. 3.3 pF
ware) Output
Solid-state switch
■ Application - Output Galvanically isolated
SITRANS LC500’s advanced electronics provide one-step, - Protection Bipolar
push-button calibration and local display for easy on-site instal-
lation and setup. - Max. switching voltage • 30 V (DC)
• 30 V peak (AC)
The unique mechanical probe design coupled with a high per-
- Max. load current 82 mA
formance transmitter gives superior performance in toxic and
aggressive chemicals, acids, caustics, adhesives and in vis- - Voltage drop < 1 V, typical at 50 mA
cous conductive and non-conductive materials.
- Time delay (pre or post switch- 1 to 60 s
The SMART 2-wire transmitter has HART® communications for ing)
remote commissioning and inspection. Loop current 3.6 to 22 mA/22 to 3.6 mA (2-wire
• Key Applications: Oil/water or foam/liquid interface measure- current loop)
ment in separators or coalescers, cryogenic applications in- Accuracy (transmitter)
cluding C02 and liquified natural gas (LNG), distillation/regen-
eration tanks with high temperatures Temperature stability 0.15 pF (0 pF) or < 0.25% (typi-
cally < 0.1%) of actual measured
value, whichever is greater over
the full temperature range
Non-linearity and repeatability < 0.1% of range and actual mea-
sured value respectively
Accuracy Deviation < 0.1% of measured
value

5/262 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500
Rated operating conditions1) Enclosure
Installation conditions • Material Aluminium, epoxy-coated
• Location Indoor/outdoor • Cable inlet 2 x ½" NPT (2 x M20x1.5, IP68
adapter, optional)
Ambient conditions
• Degree of protection Type 4X/NEMA4X/IP65, IP68
• Ambient temperature (transmitter) -40 to +85 °C (-40 to +185 °F)
Power supply 12 to 33 V DC
• Installation category II
User Interface
• Pollution degree 4
Display Local LCD, 4 digit, each 0 to 9
Medium conditions and limited alpha characters
• Relative dielectric constant εr Min. 1.5 Rotary function switch For selecting programmable
• Process temperature (probe) Temperature rating of process menu items
seal is pressure dependent. Push buttons Red +, blue -, used in conjunction
See Pressure/Temperature curves with rotary switch for program-
on page 5/270. ming
- Standard (PFA) -50 to +200 °C (-58 to +392 °F) Features
- High temperature version with -60 to +400 °C (-76 to +752 °F) Measurement current signalling According to NAMUR NE 43, sig-
thermal isolator and enamel in- nal 3.8 to 20.5 mA, fault ≤ 3.6 or ≥
sulation 21 mA (22 mA)
- Cryogenic version -200 to +200 °C (-328 to +392 °F) Safety • Inputs/outputs fully galvanically
Contact isolated
nacc.smpi@siemens.com • Polarity-insensitive current loop
for details.
• Pressure range Pressure rating of process seal is
temperature dependent.
• Fully potted
• Integrated safety barrier
5
See Pressure/Temperature curves • Diagnostics with fault alarm when: Primary variable (PV) out of limits,
on page 5/270. system failure in measurement
• Standard (PFA) -1 to 150 bar g (2175 psi g) circuit, deviation between A/D
and D/A converter, check sum,
• High temperature version -1 to 345 bar g (5004 psi g) watch dog and self-checking
(Enamel) facility
Design • Function rotary switch Positions 0 to 9, A to F
Material • SMART communication Conforming to HART Communi-
cation Foundation (HCF)
• Wetted parts material
Certificates and approvals
- Standard rod 316L stainless steel
• General Purpose CE (complies with E.C.C. require-
• Probe insulation (rod) PFA, enamel ments of EN 55011 and
• Cable 316 stainless steel/316 stainless EN 61326)
steel PFA • Non-incendive/Non-sparking • CSA/FM Class 1, Div. 2, Groups
Probe diameter A, B, C, D T4
• Rod version 16 mm (0.63") or 24 mm (0.95") • ATEX II 3G 2D EEx nA [ib] IIC T6
to T4 T100 °C
• Cable version 9 mm (0.35") with PFA jacket,
6 mm (0.24") without PFA jacket • Dust Ignition Proof • CSA/FM Class II and III, Div. 1,
Groups E, F, G
Active shield length • ATEX II 1/2 GD EEx d [ia] T6 to
• Minimum (rod version) 50 mm (1.97"), customer select- T1 T100 °C
able (order number Y02) • Explosion Proof • FM Class 1, Div. 1, Groups A, B,
Probe length C, D T4
• Rod version Max. 3.5 m (138") with 16 mm rod, • ATEX II 1/2 GD EEx d [ia] IIC T6
PFA to T1
Max. 1.5 m (59") with 16 mm rod, • Marine Lloyds Register of Shipping, Cat-
enamel egories ENV1, ENV2, ENV3 and
Max. 5.5 m (216") with 24 mm rod, ENV5
PFA
• Pressure PED 97/23/EC, CSA B51
• Cable version Max. 35 m (1378“)
• Other C-TICK (Australia)
Process connection of probe
1)
When operation is in areas classified as hazardous, observe restrictions
• Threaded mounting NPT [(Taper), ANSI/ASME according to relevant certificate. See also Pressure/Temperature curves on
B1.20.1] page 5/270.
R [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G [(BSPP), EN ISO 228-1/PF (JIS-
P), JIS B 0202]
• Flange mounting ASME, EN 1092-1

March 2009 Siemens FI 01 · 2009 US Edition 5/263


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC500, Threaded or Welded Flange C) 7ML 5 5 1 3 - SITRANS LC500, Threaded or Welded Flange C) 7 M L 5 5 1 3 -
with Cable Sensor with Cable Sensor
Inverse frequency shift capacitance level and inter- 7 7 7 77 - 77 7 7 Inverse frequency shift capacitance level and inter- 7 7 7 7 7 - 7 7 7 7
face transmitter for extreme and critical process face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours. aggressive chemicals and vapours.
Version1) Approvals
Cable, 9 mm (0.35") diameter, 316 stainless steel General Purpose 1
with PFA insulation, weighted CSA/FM Class 1, Div. 2, Groups A, B, C, D T4; 2
Add order code Y01 and plain text: “Insertion ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
length ... mm" CSA/FM Class II and III, Div. 1, Groups E, F, G T4
- 1000 to 2000 mm (39.37 to 78.74") 0E
- 2001 to 4000 mm (78.78 to 157.48") 1E ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
- 4001 to 6000 mm (157.52 to 236.22") 2E FM Class I, Div.1, Groups A, B, C, D, T4 6
- 6001 to 8000 mm (236.26 to 314.96") 3E Enclosure/Cable inlet
- 8001 to 10000 mm (315 to 393.70") 4E Aluminum epoxy coated
Longer lengths possible to a max. of 35000 mm 2 x ½" NPT, IP68 1
(114.83 ft). Contact nacc.smpi@siemens.com 2 x M20x1.5 (IP68, adapter) 2
for details.
Options
Cable, 6 mm (0.24") diameter, 316L stainless steel,
No additional options A
non-insulated, weighted
With mounting eye4) B
Add order code Y01 and plain text: “Insertion
length ... mm" Thermal isolator/remote version
- 1000 to 2000 mm (39.37 to 78.74")2) 0F Without thermal isolator or remote electronics A
- 2001 to 4000 mm (78.78 to 157.48")2) 3) 1F Isolator, only for use when temperature range is B
- 4001 to 6000 mm (157.52 to 236.22")2) 3) outside of -40 to +85 °C (-40 to +185 °F), explosion
5
2F
proof approval -40 to +70 °C (-40 to +158 °F)
- 6001 to 8000 mm (236.26 to 314.96")2) 3) 3F
- 8001 to 10000 mm (315 to 393.70")2) 3) 4F Electronic output
- Cable lengths up to 25000 mm (984.25") are No transmitter supplied 0
possible for non-conductive media. Cable 2-wire loop current 4 to 20 mA 1
lengths up to 15000 mm (590.55") are possible (transmitter MSP 2002-2 _3300 pF)
for conductive media. Contact Further designs Order code
nacc.smpi@siemens.com for details.
Please add “-Z" to Order No. and specify Order
Process connection (316L Stainless steel) code(s).
Threaded connection
1½" NPT [(Taper), ANSI/ASME B1.20.1] C0 Insertion length, specify in plain text: Y01
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F0 Y01: ... mm
1¼" NPT [(Taper), ANSI/ASME B1.20.1] K0 Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B L0 Measuring-point number/identification (max. 16
0202] characters); specify in plain text
Welded flange, raised face Acceptance test certificate: Manufacturer's test C11
1½", ASME, 150 Ib B1 certificate M to DIN 55350, Part 18 and ISO 9000
1½", ASME, 300 Ib B2 Inspection Certificate Type 3.1 per EN 10204 C12
1½", ASME, 600 Ib B3
Instruction manual See page 5/269
2", ASME, 150 Ib C1
2", ASME, 300 Ib C2 Accessories See page 5/269
2", ASME, 600 Ib C3 1)
A minimum span of 3 pF must be maintained
3", ASME, 150 Ib3) D1 2)
Available with non-conductive media only
3", ASME, 300 Ib3) D2 3) Custom shipping methods required. Contact factory for more details.
3", ASME, 600 Ib3) D3 4) Available in PFA insulated version only
4", ASME, 150 Ib3) E1 C) Subject to export regulations AL: N, ECCN: EAR99
4", ASME, 300 Ib3) E2
4", ASME, 600 Ib3) E3
6", ASME, 150 Ib3) F1
6", ASME, 300 Ib3) F2
6", ASME, 600 Ib3) F3
Welded flange, Type A flat faced
DN 40, PN 16 K4
DN 40, PN 40 K5
DN 50, PN 16 L4
DN 50, PN 40 L5
DN 80, PN 16 M4
DN 80, PN 403) M5
DN 100, PN 163) N4
DN 100, PN 403) N5
DN 125, PN 163) P4
DN 125, PN 403) P5
(Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5,
or EN 1092-1 standard.)

5/264 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC500, Threaded or Welded Flange, C) 7ML 5 5 1 5 - SITRANS LC500, Threaded or Welded Flange, C) 7 M L 5 5 1 5 -
with Rod Sensor with Rod Sensor
Inverse frequency shift capacitance level and inter- 7 7 7 77 - 77 7 7 Inverse frequency shift capacitance level and inter- 7 7 7 7 7 - 7 7 7 7
face transmitter for extreme and critical process face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours. aggressive chemicals and vapours.
Version Welded flange, raised face
Rod, 16 mm (0.63"), PFA insulated 1½", ASME, 150 Ib B1
Add order code Y01 and Y02 and plain text: “Inser- 1½", ASME, 300 Ib B2
tion length ... mm and active shield length ... mm" 1½", ASME, 600 Ib B3
- 200 to 1000 mm (7.87 to 39.37")1) 0A 2", ASME, 150 Ib C1
- 1001 to 2000 mm (39.41 to 78.74") 1A 2", ASME, 300 Ib C2
2", ASME, 600 Ib C3
- 2001 to 3000 mm (78.78 to 118.11")2) 2A
- 3001 to 3500 mm (118.15 to 137.80")2) 3A 3", ASME, 150 Ib2) D1
3", ASME, 300 Ib2) D2
Rod, 16 mm (0.63"), PFA insulated with 35 mm 3", ASME, 600 Ib2) D3
(1.38") stilling well in 316L stainless steel 2)
Add order code Y01 and Y02 and plain text: “Inser- 4", ASME, 150 Ib E1
tion length ... mm and active shield length ... mm" 4", ASME, 300 Ib2) E2
4", ASME, 600 Ib 2) E3
- 200 to 1000 mm (7.87 to 39.37")1) 3) 0B
- 1001 to 2000 mm (39.41 to 78.74")3) 1B 6", ASME, 150 Ib2) F1
6", ASME, 300 Ib2) F2
- 2001 to 3000 mm (78.78 to 118.11")2) 3) 2B 6", ASME, 600 Ib 2)
F3
- 3001 to 3500 mm (118.15 to 137.80")2) 3) 3B
Welded flange, Type A flat faced
Rod, 24 mm (0.94"), PFA insulated
Add order code Y01 and Y02 and plain text: “Inser- DN 40, PN 16 K4
DN 40, PN 40 K5
5
tion length ... mm and active shield length ... mm"
- 200 to 1000 mm (7.87 to 39.37")4) 0C DN 50, PN 16 L4
- 1001 to 2000 mm (39.41 to 78.74")4) 1C DN 50, PN 40 L5
- 2001 to 3000 mm (78.78 to 118.11")2) 4) 2C DN 80, PN 16 M4
- 3001 to 4000 mm (118.15 to 157.48")2) 4) 3C DN 80, PN 402) M5
- 4001 to 5000 mm (173.26 to 196.88")2) 4) 4C DN 100, PN 162) N4
- 5001 to 5500 mm (196.89 to 216.54")2) 4) 5C DN 100, PN 402) N5
Rod, 24 mm (0.94"), PFA insulated with 48 mm DN 125, PN 162) P4
(1.89") stilling well in 316L stainless steel DN 125, PN 402) P5
Add order code Y01 and Y02 and plain text: “Inser- (Note: Flange bolting patterns and facings dimen-
tion length ... mm and active shield length ... mm" sionally correspond to the applicable ASME B16.5,
- 200 to 1000 mm (7.87 to 39.37")5) 0D or EN 1092-1 standard.)
- 1001 to 2000 mm (39.41 to 78.74")4) 1D Approvals
- 2001 to 3000 mm (78.78 to 118.11")2) 5) 2D General Purpose 1
- 3001 to 4000 mm (118.15 to 157.48")2) 5) 3D CSA/FM Class 1, Div. 2, Groups A, B, C, D T4; 2
- 4001 to 5000 mm (173.26 to 196.88")2) 5) 4D ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
- 5001 to 5500 mm (196.89 to 216.54")2) 5) 5D CSA/FM Class II and III, Div. 1, Groups E, F, G T4
Rod, 16 mm (0.63"), Glassteel Enamel insulated ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
Add order code Y01 and Y02 and plain text: “Inser- FM Class I, Div.1, Groups A, B, C, D, T4 6
tion length ... mm and active shield length ... mm" Enclosure/Cable inlet
- 250 to 1500 mm (9.84 to 59.06")2) 5) 0E Aluminum epoxy coated
2 x ½" NPT, IP68 1
Rod, 16 mm (0.63"), Glassteel Enamel insulated, 2 x M20x1.5 (IP68, adapter) 2
with 40 mm (1.57") stilling well in 316L stainless Options
steel No additional options A
Add order code Y01 and Y02 and plain text: “Inser- Slotted holes instead of standard vent holes in still- B
tion length ... mm and active shield length ... mm" ing well (refer to instruction manual for dimen-
- 250 to 1500 mm (9.84 to 59.06")2) 5) 0F sions.) 6)

Process connection (316L Stainless steel) Thermal isolator/remote version


Threaded connection Without thermal isolator or remote electronics A
¾" NPT [(Taper), ANSI/ASME B1.20.1] A0 Thermal isolator, only for use when temperature B
1" NPT [(Taper), ANSI/ASME B1.20.1] B0 range is outside of -40 to +85 °C (-40 to +185 °F),
1½" NPT [(Taper), ANSI/ASME B1.20.1] C0 explosion proof approval -40 to +70 °C (-40 to
2" NPT [(Taper), ANSI/ASME B1.20.1] D0 +158 °F)
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E0 Remote electronics with mounting bracket and
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F0 cable7)
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] J0
R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] K0 • Length: 2 m (79") C
• Length: 3 m (118") D
1¼" NPT [(Taper), ANSI/ASME B1.20.1] N0
• Length: 4 m (158") E
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] P0 • Length: 5 m (197") F
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] R0
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B S0
0202]
G 2" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] T0

March 2009 Siemens FI 01 · 2009 US Edition 5/265


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

Selection and Ordering data Order No.


SITRANS LC500, Threaded or Welded Flange, C) 7ML 5 5 1 5 -
with Rod Sensor
Inverse frequency shift capacitance level and inter- 7 7 7 77 - 77 7 7
face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Electronic output
No transmitter supplied 0
2-wire loop current 4 to 20 mA 1
(transmitter MSP 2002-2 _3300 pF)
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01
Y01: ... mm [minimum 200 mm (7.87")]
Active shield length, specify in plain text [min. Y02
length is 50 mm (2")]: Y02: ... mm
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
Acceptance test certificate: Manufacturer's test C11
certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204 C12
Manufacturing Test Report (Electrode Test) C18

5 Instruction manual
Accessories
See page 5/269
See page 5/269
1)
A minimum span of 3 pF must be maintained
2)
Custom shipping methods required. Contact factory for more details.
3)
Available with process connection 1½" or larger
4)
Available with process connection 1" or larger
5) Available with process connection 2" or larger
6) Available with version 0B to 3B, 0D to 5D and 0F only
7)
Available with approval option 1 only
C) Subject to export regulations AL: N, ECCN: EAR99

5/266 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC500, Single Piece Flanged with Rod C) 7ML 5 5 1 7 - SITRANS LC500, Single Piece Flanged with Rod C) 7 M L 5 5 1 7 -
Sensor 77 7 77 - 7777 Sensor 77 7 77 - 7777
Inverse frequency shift capacitance level and inter- Inverse frequency shift capacitance level and inter-
face transmitter for extreme and critical process face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours. aggressive chemicals and vapours.
Version DN 100, PN 162) N4
Rod, 16 mm (0.63"), PFA insulated DN 100, PN 402) N5
Add order code Y01 and Y02 and plain text: “Inser-
tion length ... mm and active shield length ... mm" DN 125, PN 162) P4
- 250 to 1000 mm (9.84 to 39.37")1) 0A DN 125, PN 402) P5
- 1001 to 2000 mm (39.41 to 78.74") 1A Single piece flange with PTFE flange facing (appli-
- 2001 to 3000 mm (78.78 to 118.11")2) 2A cable with versions 0A to 3A and 0C to 5C)6)
- 3001 to 3500 mm (118.15 to 137.80")2) 3A 1½", ASME, 150 Ib B4
1½", ASME, 300 Ib B5
Rod, 16 mm (0.63"), PFA insulated with 35 mm 1½", ASME, 600 Ib B6
(1.34") stilling well in 316L stainless steel
Add order code Y01 and Y02 and plain text: “Inser- 2", ASME, 150 Ib C4
tion length ... mm and active shield length ... mm" 2", ASME, 300 Ib C5
- 250 to 1000 mm (9.84 to 39.37")3) 0B 2", ASME, 600 Ib C6
- 1001 to 2000 mm (39.41 to 78.74")3) 1B 3", ASME, 150 Ib2) D4
- 2001 to 3000 mm (78.78 to 118.11")2) 3) 2B 3", ASME, 300 Ib2) D5
- 3001 to 3500 mm (118.15 to 137.80")2) 3) 3B 3", ASME, 600 Ib2) D6
Rod, 24 mm (0.94"), PFA insulated 4", ASME, 150 Ib2) E4
Add order code Y01 and Y02 and plain text: “Inser- 4", ASME, 300 Ib2) E5
4", ASME, 600 Ib2)
5
tion length ... mm and active shield length ... mm" E6
- 250 to 1000 mm (9.84 to 39.37")4) 0C 6", ASME, 150 Ib2) F4
- 1001 to 2000 mm (39.41 to 78.74")4) 1C 6", ASME, 300 Ib2) F5
- 2001 to 3000 mm (78.78 to 118.11")2) 4) 2C 6", ASME, 600 Ib2) F6
- 3001 to 4000 mm (118.15 to 157.48")2) 4) 3C Single piece flange with PTFE flange facing (appli-
- 4001 to 5000 mm (173.26 to 196.88")2) 4) 4C cable with versions 0A to 3A, 0C to 5C)6)
- 5001 to 5500 mm (196.89 to 216.54")2) 4) 5C
DN 40, PN 16 K6
Rod, 24 mm (0.94"), PFA insulated with 48 mm DN 40, PN 40 K7
(1.89") stilling well in 316L stainless steel
DN 50, PN 16 L6
Add order code Y01 and Y02 and plain text: “Inser-
DN 50, PN 40 L7
tion length ... mm and active shield length ... mm"
- 250 to 1000 mm (9.84 to 39.37") 0D DN 80, PN 16 M6
- 1001 to 2000 mm (39.41 to 78.74")2) 5) 1D DN 80, PN 402) M7
- 2001 to 3000 mm (78.78 to 118.11")2) 5) 2D DN 100, PN 162) N6
- 3001 to 4000 mm (118.15 to 157.48")2) 5) 3D DN 100, PN 402) N7
- 4001 to 5000 mm (173.26 to 196.88")2) 5) 4D DN 125, PN 162) P6
- 5001 to 5500 mm (196.89 to 216.54")2) 5) 5D DN 125, PN 402) P7
Rod, 16 mm (0.63"), Glassteel Enamel insulated (Note: Flange bolting patterns and facings dimen-
Add order code Y01 and Y02 and plain text: “Inser- sionally correspond to the applicable ASME B16.5,
tion length ... mm and active shield length ... mm" or EN 1092-1 standard.)
- 300 to 1500 mm (11.81 to 59.01")2) 5) 0E Approvals
Rod, 16 mm (0.63"), Glassteel Enamel insulated, General Purpose 1
with 40 mm (1.57") stilling well in 316L stainless CSA/FM Class 1, Div. 2, Groups A, B, C, D T4; 2
steel ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
Add order code Y01 and Y02 and plain text: “Inser- CSA/FM Class II and III, Div. 1, Groups E, F, G T4;
tion length ... mm and active shield length ... mm" ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
- 300 to 1500 mm (11.81 to 59.01")2) 5) 0F FM Class I, Div.1, Groups A, B, C, D, T4 6
Process connection (316L Stainless steel) Enclosure/Cable inlet
Single piece flange, raised face Aluminum epoxy coated
1½", ASME, 150 Ib B1 2 x ½" NPT, IP68 1
1½", ASME, 300 Ib B2 2 x M20x1.5 (IP68, adapter) 2
1½", ASME, 600 Ib B3
Options
2", ASME, 150 Ib C1 None A
2", ASME, 300 Ib C2 Slotted holes instead of standard vent holes in still- B
2", ASME, 600 Ib C3 ing well (Refer to manual for dimensions)7)
3", ASME, 150 Ib2) D1 Thermal isolator/remote version
3", ASME, 300 Ib2) D2 Without thermal isolator or remote electronics A
3", ASME, 600 Ib2) D3 Isolator, only for use when temperature range is B
4", ASME, 150 Ib2) E1 outside of -40 to +85 °C (-40 to +185 °F), explosion
4", ASME, 300 Ib2) E2 proof approval -40 to +70 °C (-40 to +158 °F)
4", ASME, 600 Ib2) E3 Remote electronics with mounting bracket and
6", ASME, 150 Ib2) F1 cable8)
6", ASME, 300 Ib2) F2 • Length: 2 m (79") C
6", ASME, 600 Ib2) F3 • Length: 3 m (118") D
Single piece flange, Type B1 raised face • Length: 4 m (158") E
DN 40, PN 16 K4 • Length: 5 m (197") F
DN 40, PN 40 K5
DN 50, PN 16 L4
DN 50, PN 40 L5
DN 80, PN 16 M4
DN 80, PN 402) M5

March 2009 Siemens FI 01 · 2009 US Edition 5/267


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

Selection and Ordering data Order No.


SITRANS LC500, Single Piece Flanged with Rod C) 7ML 5 5 1 7 -
Sensor 77 7 77 - 7777
Inverse frequency shift capacitance level and inter-
face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Electronic output
No transmitter supplied 0
2-wire loop current 4 to 20 mA 1
(transmitter MSP 2002-2 _3300 pF)
Further designs Order code
Please add “-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01
Y01: ... mm
Y01 for version 0A to 5D: min. = 200 mm (7.87")
Y01 for version 0E and 0F: min. = 250 mm (9.84")
Active shield length, specify in plain text [min. Y02
length is 50 mm (2")]: Y02: ... mm
Y02 for version 0A to 5D: min. = 50 mm (1.97")
Y02 for version 0E and 0F: min. = 100 mm (3.94")
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
Measuring-point number/identification (max. 16
characters); specify in plain text
5 Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11

Inspection Certificate Type 3.1 per EN 10204 C12


Manufacturing Test Report (Electrode Test) C18
Instruction manual See page 5/269
Accessories See page 5/269
1)
A minimum span of 3 pF must be maintained
2)
Custom shipping methods required. Contact factory for more details.
3)
Available with process connection 1½" or larger
4)
Available with process connection 1" or larger
5)
Available with process connection 2" or larger, and only available with pro-
cess connection options C1 to C3, D1 to D3, E1 to E3, F1 to F3, L4 and L5,
M4 and M5, N4 and N5, P4 and P5
6) Not available with versions 0E and 0F
7) Available with version 0B to 3B, 0D to 5D and 0F only
8)
Available with approval option 1 only
C) Subject to export regulations AL: N, ECCN: EAR99

5/268 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS LC500, Extended Cable version with 7ML 5 5 2 3 - SITRANS LC500, Extended Cable version with 7ML 5 5 2 3 -
Rod Sensor, threaded connection or welded 7 7 7 77 - 77 7 7 Rod Sensor, threaded connection or welded 7 7 7 77 - 77 7 7
flange1) flange1)
Inverse frequency shift capacitance level and inter- Inverse frequency shift capacitance level and inter-
face transmitter for short range continuous mea- face transmitter for short range continuous mea-
surement in large storage vessels. surement in large storage vessels.
Version2) Thermal isolator
Rod, 16 mm (0.63"), PFA insulated and 316L stain- Without thermal isolator A
less steel flexible extension tube Isolator, only for use when temperature range is B
Total insertion length: outside of -40 to +85 °C (-40 to +185 °F), explosion
Add order code Y01 and plain text: “Total insertion proof approval -40 to +70 °C (-40 to +158 °F)
length ... mm and Y02 and plain text: Active shield Electronic output
length ... mm"3) 4) No transmitter supplied 0
- 5000 to 10000 mm (196.85 to 393.70")1) 0A 2-wire loop current 4 to 20 mA 1
- 10001 to 15000 mm (393.74 to 590.55")1) 1A (transmitter MSP 2002-2 _3300 pF)
- 15001 to 20000 mm (590.59 to 787.40")1) 2A
Further designs Order code
- 20001 to 25000 mm (787.44 to 984.25")1) 3A Please add “-Z" to Order No. and specify Order
- 25001 to 30000 mm (984.29 to 1181.10")1) 4A code(s).
- 30001 to 35000 mm (1181.14 to 1377.95")1) 5A
Rod, 24 mm (0.94"), PFA insulated and 316L stain- Total Insertion length, specify in plain text: Y01
less steel flexible extension tube Y01: ... mm [min. PFA rod length 200 mm
Total insertion length: (7.87")]3)
Add order code Y01 and plain text: “Total insertion Active shield length, specify in plain text: Y02: ... Y02
length ... mm and Y02 and plain text: Active shield mm [min. length 50 mm (2")]4)
length ... mm"3) 4)
Stainless steel tag [69 mm x 50 mm (2.71 x 1.97")]: Y15
- 5000 to 10000 mm (196.85 to 393.70")1) 0B
Measuring-point number/identification (max. 16
- 10001 to 15000 mm (393.74 to 590.55")1)
- 15001 to 20000 mm (590.59 to 787.40")1)
1B
2B
characters); specify in plain text
Acceptance test certificate: Manufacturer's test C11
5
- 20001 to 25000 mm (787.44 to 984.25")1) 3B
certificate M to DIN 55350, Part 18 and ISO 9000
- 25001 to 30000 mm (984.29 to 1181.10")1) 4B
- 30001 to 35000 mm (1181.14 to 1377.95")1) 5B Inspection Certificate Type 3.1 per EN 10204 C12
Process connection (316L stainless steel) Instruction manual See page 5/269
Threaded connection Accessories See page 5/269
2" NPT [(Taper), ANSI/ASME B1.20.1] A0
1)
R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] B0 Custom shipping methods required. Contact factory for more details.
G 2" [(BSPP), EN ISO 228-1/PF (JIS-P) JIS B 0202] 2)
D0 A minimum span of 3 pF must be maintained.
3) See dimension drawings on page 5/59 for further explanation of Y01.
Welded flange, raised face 4)
Inactive length is equal to the flexible extension plus transition. See dimen-
2", ASME, 150 Ib C1 sion drawings on page 5/59 for further explanation of Y02.
2", ASME, 300 Ib C2
3", ASME, 150 Ib1) D1 Selection and Ordering data Order No.
3", ASME, 300 Ib1) D2
Instruction manual for SITRANS LC500
4", ASME, 150 Ib1) E1 English 7ML1998-5GE01
4", ASME, 300 Ib1) E2
French 7ML1998-5GE11
6", ASME, 150 Ib1) F1
6", ASME, 300 Ib1) F2 Spanish 7ML1998-5GE21
Welded flange, Type A flat faced German 7ML1998-5GE31
Note: The instruction manual should be ordered as
DN 50, PN 16 L4 a separate line item on the order.
DN 50, PN 40 L5
This device is shipped with the Siemens Milltronics
DN 80, PN 16 M4
manual CD containing the complete ATEX Quick
DN 80, PN 401) M5
Start and instruction manual library.
DN 100, PN 161) N4
DN 100, PN 401) N5 Accessories
DN 125, PN 161) P4 Transmitter, MSP 2002-1, 330 PF1) L) 7ML1830-1JP
DN 125, PN 401) P5 Transmitter, MSP 2002-2, 3300 PF1) L) 7ML1830-1JQ
(Note: Flange bolting patterns and facings dimen- Transmitter, MSP 2002-3, 6600 PF (used with con- L) 7ML1830-1JR
sionally correspond to the applicable ASME B16.5, ductive fluids and probe lengths >10000 mm)1)
or EN 1092-1 standard.)
1)
Transmitters not suitable for Intrinsically Safe application (ATEX II 1G EEx
Approvals ia IIC T4 or CSA/FM Class 1 Div 1 Grp A,B,C and D)
General Purpose 1
CSA/FM Class 1, Div. 2, Groups A, B, C, D T4; 2 L) Subject to export regulations AL: N, ECCN: 3A991X
ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III, Div. 1, Groups E, F, G T4; Please contact nacc.smpi@siemens.com for special requests.
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C 4
FM Class I, Div.1, Groups A, B, C, D, T4 6
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68 1
2 x M20x1.5 (IP68, adapter) 2
Options
No additional options A
With mounting eye B

March 2009 Siemens FI 01 · 2009 US Edition 5/269


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

■ Characteristic curves

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)

5/270 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515)

March 2009 Siemens FI 01 · 2009 US Edition 5/271


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)

5/272 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)

March 2009 Siemens FI 01 · 2009 US Edition 5/273


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)

5/274 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)

March 2009 Siemens FI 01 · 2009 US Edition 5/275


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)

5/276 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)

March 2009 Siemens FI 01 · 2009 US Edition 5/277


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517)

5/278 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517)

March 2009 Siemens FI 01 · 2009 US Edition 5/279


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

■ Dimensional drawings

SITRANS LC500 dimensions - Cable Versions

5/280 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 dimensions - Cable Versions

March 2009 Siemens FI 01 · 2009 US Edition 5/281


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 dimensions - Rod Versions

5/282 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 dimensions - Rod Versions

March 2009 Siemens FI 01 · 2009 US Edition 5/283


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC500

SITRANS LC500 probe version Standard Extended Cable version with Rod
Sensor
Process connection types Threaded or welded flange Single piece flanged Threaded or welded flange
Threaded Available as standard – Available as standard
Flange Available as standard Available as standard Available as standard
Sanitary fitting clamp – – –

Process connection materials


Stainless steel 316L Available as standard Available as standard Available as standard
Probe insulation
PFA Available as standard Available as standard Available as standard
Enamel Available as standard Available as standard –
Length and Process parameters1)
Rod length for PFA 16 mm version Min. 200 mm (7.87") Min. 200 mm (7.87") Min. 200 mm (7.87")
Max. 3500 mm (137.80") Max. 3500 mm (137.80") Max. 3500 mm (137.80")
Rod length for PFA 24 mm version Min. 200 mm (7.87") Min. 200 mm (7.87") Min. 200 mm (7.87")
Max. 5500 mm (216.54") Max. 5500 mm (216.54") Max. 5500 mm (216.54")
Rod length for enamel 16 mm ver- Min. 250 mm (9.84") Min. 250 mm (9.84") –
sion Max. 1500 mm (59.06") Max. 1500 mm (59.06")

5 Cable length Min. 1000 mm (39.37")


Max. 35000 mm (1377.95")
Min. 1000 mm (39.37")
Max. 35000 mm (1377.95")
Min. 5000 mm (196.85")2)
Max. 35000 mm (1377.95")2)

Maximum pressure 150 bar g (2175 psi g) 150 bar g (2175 psi g) 5 bar g (73 psi g)
Maximum temperature +200 °C (+392 °F) +200 °C (+392 °F) +100 °C (+212 °F)
1)
Pressure rating of process seal is temperature dependent. See Pres-
sure/Temperature curves of respective configuration
2)
Refers to total insertion length. See dimension drawing on page 5/280 for
further explanation
- Not available as standard

■ Schematics

SITRANS LC500 connections

5/284 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous level measurement - Capacitance transmitters
SITRANS LC300 and LC500 Specials

■ Selection and Ordering Data


LC300 and LC500 Specials. See note 1. LC500 Blind Lid
LC300 Cable Extensions, 316L stainless steel

Spare LC500 aluminum blind lid A5E01163729


Kit, Stainless steel cable extension, 1 m, adjust- A5E01163688 LC500 Mounting Eye
able by customer
Kit, Stainless steel cable extension, f3 m, adjust- A5E01163689
able by customer
Kit, Stainless steel cable extension, 5 m, adjust- A5E01163690
able by customer
Kit, Stainless steel cable extension, 10 m, adjust- A5E01163691 Spare mounting eye (PFA cable version only) A5E01163717
able by customer
LC500 Mounting Bracket
Kit, Stainless steel cable extension, 15 m, adjust- A5E01163693
able by customer
Kit, Stainless steel cable extension, 20 m, adjust- A5E01163695
able by customer

5
LC300 Cable Extensions,
316 stainless steel with PFA coating
Spare mounting bracket A5E01163730
LC500 Sanitary Versions See note 2.

Note 1: Special flange sizes and facings are available. Please


contact nacc.smpi@siemens.com for part number and pricing.
Kit, PFA cable extension, 1 m A5E01163709 Submit Application Questionnaire found on page 5/8.
Kit, PFA cable extension, 3 m A5E01163710 Note 2: Please contact nacc.smpi@siemens.com for part num-
Kit, PFA cable extension, 5 m A5E01163711 ber and pricing. Submit Application Questionnaire found on
page 5/8.
Kit, PFA cable extension, 10 m A5E01163712
Please contact nacc.smpi@siemens.com for special requests.
Kit, PFA cable extension, 15 m A5E01163713
C) Subject to export regulations AL: N, ECCN: EAR99
Kit, PFA cable extension, 20 m A5E01163714
LC300 Mounting Eye

Spare mounting eye (LC300 PFA versions only) A5E01163717


LC300 Weight Kit, 316L stainless steel

Kit, Spare stainless steel weight. To be used in A5E01163727


any cable version of CLS300, or stainless steel
cable version of LC300
LC500 Gasket (IP65), Silicone

Spare gasket, LC500 enclosure version, IP65 A5E01163728 C)

March 2009 Siemens FI 01 · 2009 US Edition 5/285


© Siemens AG 2009

Level instruments
Continuous measurement - Open channel flow - Ultrasonic controllers
OCM III

■ Overview mA output 0/4 to 20 mA, isolated


• Max. load 1 KΩ max. load
• Resolution 5 uA
• Isolation 300 V AC continuous
• DC output +24 V DC, 20 mA average to
200 mA at 1/10 duty cycle
max. 0 to 20
Accuracy
Error in measurement ±1 mm/m, calculated error less
than 0.02%
Resolution 0.2 mm (0.007")
Rated operating conditions
Installation conditions
Location Indoor/outdoor
Installation category II
Pollution degree 4
Ambient conditions
The OCM III is a high accuracy ultrasonic flow monitor for open
channels. Ambient temperature (enclosure) -20 to +50 °C (-5 to +122 °F)
Design

5 ■ Benefits Weight 2.3 kg (5.1 lbs)


• Influent and effluent monitor Material (enclosure) Polycarbonate
• BS 3680 calculations provide exceptional accuracy in mea- Degree of protection (enclosure) IP65/Type 4X/NEMA 4X
suring flow
• 1 to 24 months data log, subject to logging rate Cable
• RS-232 serial communication Transducer and mA output signal • Transducer: co-axial to be
RG62-A/U low capacity
• High accuracy on unique or non-standard weirs and flumes
• mA output signal to be 2 copper
• AC and DC operation. Automatically switches to battery oper- conductors, twisted, with foil
ation for uninterrupted power shield/drain wire, 300 V 0.5 to
• Dual power input 0.75 mm² (22 to 18 AWG)
• Low power remote monitoring • Relay/power to be copper con-
ductors per local requirements
• Flow Reporter software available for remote monitoring, con-
to meet 250 V 5 A contact rating
figuration and data retrieval
Max. separation between trans- 183 m (600 ft)
■ Application ducer and transceiver
Displays and controls LCD 5 x 7 dot matrix display with
In addition to monitoring flowrate in sewage works, OCM III can 2 lines of 40 characters each
monitor industrial discharge, rainfall/storm water studies, in- Programming Via removable programmer and
flow/infiltration studies and sewer system evaluations. As well as communication link
being compatible with many standard weirs and flumes, the pro-
grammable head versus flow curve (up to 16 points) accurately Memory 3 V battery (NEDA 5003LC or
equivalent), operating life 1 year,
defines flow rate on unique or non-standard weirs and flumes. SuperCap capacitor for back-up
The OCM III has data logging and is adjustable from once per during battery replacement
minute to once a day. It records the average flow rate for that Power supply
time period. Daily, it records minimum/maximum of temperature
and flow rates, and the time they occurred, as well as the daily AC version 100/115/200/230 V AC ± 15%,
50/60 Hz, 20 VA max.
total. Advanced functions include variable rate logging. It can be
pre-programmed to log at a higher rate when needed. Under DC version 9 to 30 V DC, 8 W max.
steady conditions, the OCM III automatically logs less frequently Certificates and approvals CE, FM, CSANRTL/C, MCERTS,
to conserve data log space. C-TICK2)
The OCM III has two-way communication via RS-232 with a mo- Communication RS-232 or ± 20 mA bipolar current
dem or a bi-polar current loop with a current-to-voltage commu- loop, 300, 600, 1200, 2400, 4800,
nication converter. Data logs can be downloaded to a file that 9600, 19200 baud
can be manipulated into a spreadsheet or ASCII format. Options
Temperature sensor TS-2
■ Technical specifications Remote monitoring Flow Reporter, a Windows®-
Mode of Operation based configuration software and
data extractor
Measuring range1) 0.3 to 1.2 m (1 to 4 ft) or 0.6 to
3 m (2 to 10 ft) Velocity sensor Consult with factory
1)
Output Program range is defined as the empty distance to the face of the trans-
ducer plus any range extension
Transducer Echomax® XRS-5, 44 kHz 2)
EMC performance available upon request
Relays 3 alarm/control relays, 1 SPDT Form Windows® is a registered trademark of Microsoft Corporation
C contact per relay, rated 5 A at
250 V AC non-inductive or 30 V DC

5/286 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Continuous measurement - Open channel flow - Ultrasonic controllers
OCM III

Selection and Ordering data Order No.


OCM III C) 7 M L 1 0 0 2 -
High accuracy ultrasonic flow monitor for open
7A7 0 7
channels.
Input voltage
AC, voltage selector switch 0
Enclosure
Wall mount, standard enclosure A
Wall mount, 6 entries, M20 holes1) B
Approvals
CSANRTL/C, FM, CE (EN61326), C-TICK 5
CE2) 6
Instruction manual
English C) 7ML1998-5AB01
French C) 7ML1998-1AB11
Spanish C) 7ML1998-1AB21

German C) 7ML1998-1AB31
Note: The instruction manual should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Required equipment
TS-2 Temperature Sensor
5
TS-2, 1 m cable C) 7ML1812-1AA1
TS-2, 5 m cable C) 7ML1812-2AA1
TS-2, 10 m cable C) 7ML1812-3AA1

TS-2, 30 m cable C) 7ML1812-4AA1


TS-2, 50 m cable C) 7ML1812-5AA1
TS-2, 70 m cable C) 7ML1812-6AA1

TS-2, 90 m cable C) 7ML1812-7AA1


TS-2 Instruction manual C) 7ML1998-5EW01
Note: The TS-2 instruction manual should be
ordered as a separate line item on the order.
Accessories
Handheld programmer 7ML1830-2AA
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), 7ML1930-1AC
one text line, suitable for enclosure
M20 cable gland kit (6 M20 cable glands, 7ML1830-1GM
6 M20 nuts, 3 stop plugs)
Flow Reporter software license B) 7ML1930-1AK
Flow Reporter Kit (includes disk, authorization B) 7ML1930-1AL
code and cable)
Spare parts
Card, Mother, main C) 7ML1830-1MG
Card, daughter/display C) 7ML1830-1LT
Card, LCD 7ML1830-1KY
Eprom C) 7ML1830-1KW
Battery C) 7ML1830-1JV
OCM III Lid overlay 7ML1830-1KV
1) Available with approval option 6 only
2)
Available with enclosure option B only
B) Subject to export regulations AL: N, ECCN: EAR99S
C) Subject to export regulations AL: N, ECCN: EAR99

March 2009 Siemens FI 01 · 2009 US Edition 5/287


© Siemens AG 2009

Level instruments
Continuous measurement - Open channel flow - Ultrasonic controllers
OCM III

■ Dimensional drawings

16 mm 209 mm
(0.6”) (8.2”) 106 mm
lid screws (4.2”)
172 mm (6 places) 91 mm
(6.8”) (3.6”)

programmer
285 mm
(11.2”)

267 mm
(10.5”)
1 2 3 4

5 6 7 8

9 A
0

5 D

U
F

P C

lid
Suitable location for conduit entrances. mounting holes
Siemens Milltronics recommends using a punch (accessed under enclosure
for making holes in enclosure. lid) 4.3 mm (0.17”)
dia. / 4 places
customer
mounting screw

OCM III dimensions

■ Schematics
SHLD
SHLD

SHLD

SHLD
COM

COM
WHT
BLK
Hot

Vel Aux
Input Input
Position SW1
Transducer Current O/P Bipolar I/O RS-232 I/O Temp Sensor P 24 V Output Input Power for 100/115/
max. load 200/230 V AC
average 20 mA operation
Pulse 200 mA (50/60 Hz,
1/10 duty 20 VA)
Notes:
1. Use RG62-A/U Coaxial (or equivalent) for extensions up to 183 m (600 ft). Run in grounded metal conduit, separate from other wiring.
2. Each relay has 1 set of form ‘C’ (SPDT) contacts, relay rated at 5A, 250 V AC, non-inductive, when equal or lower rated limiting fuses are installed.
Relay de-energized when in alarm conditions and energized for pump control.

OCM III connections

5/288 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Communications and Displays
SmartLinx module

■ Overview ■ Technical specifications


Module type Allen Bradley Remote I/O
• Interface RIO
• Transmission rate 57.6, 115.2 or 230.4 Kbaud
• Rack address 1 to 73, ¼ to full rack
• Connection RIO slave
• SmartLinx module compatibility • SITRANS LU01
• SITRANS LU02
• SITRANS LU10
• SITRANS LUC500
• MultiRanger 100/200
• HydroRanger 200

Module type PROFIBUS DP


• Interface RS-485 (PROFIBUS standard)
® • Transmission rate All valid PROFIBUS DP rates from
SmartLinx modules provide direct digital connection to popular 9600 Kbps to 12 Mbps
industrial communications buses with true plug-and-play com-
patibility with products manufactured by Siemens. • Rack address 0 to 99

■ Benefits
• Connection
• SmartLinx module compatibility
Slave
• SITRANS LU01
5
• Fast, easy installation • SITRANS LU02
• Direct connection: no additional installation required • SITRANS LU10
• Scaleable application layer allows for optimized network • SITRANS LUC500
bandwidth and memory requirements • MultiRanger 100/200
• Modules available for PROFIBUS DP, Allen-Bradley® Remote • HydroRanger 200
I/O and DeviceNetTM, Modbus® RTU
®
Modbus is a registered trademark of Schneider Electric.
® Module type MODBUS RTU
Allen-Bradley is a registered trademark of Rockwell Automation
TM
DeviceNet is a trademark of Open DeviceNet Vendor Association • Interface RS-232 or RS-485
• Transmission rate in bps 1200, 2400, 4800, 9600, 19200,
■ Application 38400
Many Siemens products include HART®, PROFIBUS PA and • Rack address 1 to 247
Modbus communications. For additional communication mod- • Connection Slave
ules, SmartLinx cards are the answer.
• SmartLinx module compatibility • SITRANS LU01
They’re fast and easy to install, and can be added at any time. • SITRANS LU02
The module simply plugs into the socket on any SmartLinx-en-
abled product. They require no secondary private buses or gate- • SITRANS LU10
ways and no separate wiring. There are no extra boxes to con- Included with product:
nect to your network so there’s a minimum load on engineering • SITRANS LUC500
and maintenance staff.
• MultiRanger 100/200
SmartLinx provides all data from the instrument, including mea- • HydroRanger 200
surement and status, and allows changes to operation parame-
ters to be done over the bus or telemetry link. The user can se-
lect which data in the application layer to transfer over the bus. Module type DeviceNet
This selection saves bandwidth and memory and optimizes data
throughput and speeds up the network, enabling you to connect • Interface DeviceNet physical layer
more instruments to your network. • Transmission rate in kbps 125, 250, 500
• Rack address 0 to 63
• Connection Slave (group 2)
• SmartLinx module compatibility • SITRANS LUC500
• MultiRanger 100/200
• HydroRanger 200

March 2009 Siemens FI 01 · 2009 US Edition 5/289


© Siemens AG 2009

Level instruments
Communications and Displays
SmartLinx modules

Selection and Ordering data Order No.


SmartLinx® module for SITRANS LU01, LU02,
LU10
Allen-Bradley Remote I/O module C) 7ML1830-1CP
PROFIBUS DP module 7ML1830-1CQ
Modbus RTU module 7ML1830-1CR
SmartLinx module for SITRANS LUC500 Rack
and Panel Mount models
Allen-Bradley Remote I/O module C) 7ML1830-1HP
PROFIBUS DP module C) 7ML1830-1CS
DeviceNet module 7ML1830-1HQ
SmartLinx module for SITRANS LUC500 Wall
Mount model, MultiRanger 100/200,
HydroRanger 200
Allen-Bradley Remote I/O module C) 7ML1830-1HS
PROFIBUS DP module C) 7ML1830-1HR
DeviceNet module 7ML1830-1HT
Instruction manuals
Allen-Bradley Remote I/O communications C) 7ML1998-1AP03
module, English
PROFIBUS communications module
• English C) 7ML1998-1AQ03
• French C) 7ML1998-1AQ12
5 • German C) 7ML1998-1AQ32

Modbus RTU communications module, English C) 7ML1998-1BF01


Modbus RTU communications module, German C) 7ML1998-1BF31
SmartLinx modem, English C) 7ML1998-1BG01
DeviceNet, English C) 7ML1998-1BH02
This device is shipped with the Siemens Milltronics
manual CD containing ATEX Quick Starts and
instruction manuals.
Spare SmartLinx software
Allen-Bradley data diskette C) 7ML1830-1CK
PROFIBUS DP data diskette C) 7ML1830-1CL
DeviceNet data diskette C) 7ML1830-1CM

C) Subject to export regulations AL: N, ECCN: EAR99

5/290 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Communications and Displays
Dolphin Plus Software

■ Overview Selection and Ordering data Order No.


Dolphin Plus C) 7 M L 1 8 4 1 -
Instrument configuration software to quickly and 7AA 0 7
easily configure, monitor, tune and diagnose most
Siemens devices remotely, from your desktop PC or
connected directly in the field using a laptop.
Dolphin Plus Software includes a software CD, and
a nine pin adapter with a 2.1 m (82.7") cable for
connection to a PC serial port.
RS-485 to RS-232 converter
No 0
Yes 1
ComVerter
No 0
Yes 1
Instruction manual
• Connection manual, English:
Included on Dolphin Plus CD and available at
www.siemens.com/processautomation
This device is shipped with the Siemens Milltronics
Dolphin Plus is instrument configuration software that allows you manual CD containing ATEX Quick Starts and
to quickly and easily configure, monitor, tune and diagnose sev- instruction manuals.
eral Siemens level devices remotely (see list below). Remote ac-
cess is available using your desktop PC or connected directly in
the field using a laptop.
Spare parts
Converter, RS 485 to RS 232 (D-Sub) C) 7ML1830-1HA 5
Kit containing one 9-pin D-Sub to RJ11 Adapter 7ML1830-1MC
and one 2.1 meter telephone cable with two male
■ Benefits jacks
• Real-time monitoring and adjustment of parameters ComVerter, Infrared link C) 7ML1830-1MM

• On-screen visualization of process values C) Subject to export regulations AL: N, ECCN: EAR99
• Saving and visualization of echo profiles for a wide range of
Siemens level meters
• Copying of data for programming several devices
• Quick setup and commissioning of device
• Generation of configuration reports within seconds
Note:
The Dolphin Plus software is only available in English.

■ Application
Dolphin Plus is easy to install and use. Just load the software
from the CD. In minutes, you’re ready to set up or modify com-
plete parameter configurations for one or more devices.
Following configuration, you can alter parameters, upload and
download parameter sets to and from disk, and use parameter
sets saved from other instruments. Reading of echo profiles per-
mits fine tuning without the need for special instruments. Built-in
quick start wizards and help functions guide you through the en-
tire process.
Compatibility
Dolphin Plus is compatible with Microsoft Windows
95/98/NT4/Me/2000/XP and works with a wide range of Siemens
products, including:
• SITRANS LUC500
• HydroRanger Plus
• SITRANS LU10
• SITRANS LU02
• SITRANS LU01
Connection to a Siemens instrument may be a direct RS-232 se-
rial connection or via an RS-485 converter or Siemens infrared
ComVerter, depending on the instrument being configured.
Meets VDE 2187 user interface requirements.
(Most other Siemens level devices use Simatic PDM configura-
tion software.)

March 2009 Siemens FI 01 · 2009 US Edition 5/291


© Siemens AG 2009

Level instruments
Communications and Displays
SITRANS RD100

■ Overview ■ Technical specifications


Mode of operation
• Measuring principle Analog to digital conversion
• Measuring range 4 to 20 mA
• Measuring points 1 instrument only
Accuracy ±0.1 % of span ±1 count
Rated operating conditions
Ambient conditions
Operating temperature range -40 to +85 ºC (-40 to +185 ºF)
Design
Weight 340 g (12 oz)
Material (enclosure) Impact-resistant glass filled poly-
carbonate body and clear poly-
carbonate cover
Degree of protection NEMA 4X, IP67
Power supply
The SITRANS RD100 is a 2-wire loop powered, NEMA 4X en-
External loop power supply 30 V DC max.
closed remote digital display for process instrumentation.
Display • 1.0" (2.54 cm) high LCD
■ Benefits
5 • Easy setup
• Numeric range from -1000 to
+1999
Certificates and approvals
• Approved for hazardous locations
Hazardous
• NEMA 4X, IP67 impact-resistant enclosure
• Simple two-step calibration • Intrinsically Safe • CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G T4
• Two modes of input allow for easy servicing, with no interrup-
tion of loop required • CSA/FM Class I, Zone 0, Group
IIC

■ Application • Non-incendive • CSA/FM Class I, Div. 2, Groups


A, B, C, D
The RD100 is very versatile. It can be installed indoors or out- • CSA/FM Class II and III, Div. 2,
doors, in hot or cold environments, and in safe or hazardous ar- Groups F and G
eas. Options
It has been approved by FM and CSA as Intrinsically Safe and • Mounting • 2" (5.08 cm) pipe mounting kit
non-incendive, and operates from -40 to +85 ºC (-40 to +185 ºF), (zinc plated or stainless steel)
adding only 1 V to the loop.
• Panel mounting kit
The RD100 has a large 1" (2.54 cm) high display making it easy
to read.
Calibration consists of a quick two-step process involving the Selection and Ordering data Order No.
adjustment of only two non-interacting potentiometers. SITRANS RD100 C) 7 M L 5 7 4 1 -

• Key Applications: Remotely displays process variables in A 2-wire loop powered, NEMA 4X enclosed remote 7AA 0 0 - 0
level, flow, pressure, temperature and weighing applications, digital display for process instrumentation.
in a 4 to 20 mA loop. Conduit hole location (½")
None } 1
Bottom 2
Rear 3
Top 4
Instruction manual
English C) 7ML1998-5JU01
French C) 7ML1998-5JU11
German C) 7ML1998-5JU31
Note: The instruction manual should be ordered as
a separate line item.
This device is shipped with the Siemens Milltronics
manual CD containing ATEX Quick Starts and
instruction manuals.
Accessories
Panel mount kit C) 7ML1930-1BN
2" (5.08 cm) pipe mounting kit (zinc plated seal) C) 7ML1930-1BP
2" (5.08 cm) pipe mounting kit (stainless steel, C) 7ML1930-1BQ
Type 304, EN 1.4301)
C) Subject to export regulations AL: N, ECCN: EAR99
} Available ex stock.

5/292 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Communications and Displays
SITRANS RD100

■ Dimensional drawings

SITRANS RD100 dimensions


5
■ Schematics

SITRANS RD100 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/293


© Siemens AG 2009

Level instruments
Communications and Displays
SITRANS RD200

■ Overview

The SITRANS RD200 is a universal input, panel mount remote


digital display for process instrumentation.

5 ■ Benefits
• Easy setup and programming via front panel buttons or re-
motely using RD software
• Display readable in sunlight
• Universal input: accepts current, voltage, thermocouple and
RTD signals
• Single or dual 24 V DC transmitter power supply
• Serial communication using built in protocol or optional Mod-
bus® RTU
• Two optional relays for alarm indication or process control ap-
plications
• Linear or square root function supported
• Meter Copy feature to reduce setup time, cost or errors
• RD software supporting remote configuration, monitoring and
logging for up to 100 displays

■ Application
The RD200 is a universal remote display for level, flow, pressure,
temperature, weighing, and other process instruments.
Data can be remotely collected, logged and presented from as
many as 100 displays on your local computer using the free
downloadable RD Software.
The display accepts a single input of current, voltage, thermo-
couple, and RTD. This makes the RD200 an ideal fit for use with
most field instruments.
The RD200 can be set up as a standard panel mount, or com-
bined with optional enclosures to allow it to house up to 6 dis-
plays.
• Key Applications: Tank farms, pump alternation control, local
or remote display of level, temperature, flow, pressure and
weighing instrument values, PC monitoring and data logging
with RD Software.

5/294 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Communications and Displays
SITRANS RD200

■ Technical specifications Electrical connection


• mA output signal 2-core copper conductor, twisted,
Mode of operation shielded, 0.82 to 3.30 mm² (18 to
• Measuring principle Analog to digital conversion 12 AWG), Belden® 8760 or equiv-
alent is acceptable
• Measuring points • 1 instrument
• Electrical connection and relay Copper conductor according to
• Remote monitoring of 100 instru- connection local requirements, rated 3A @
ments with PC and RD Software 250 V AC
Input Power supply
Measuring range Input voltage option 1 85 to 265 V AC, 50/60 Hz; 90 to
• Current • 4 to 20 mA, 0 to 20 mA 265 V DC, 20 W max.
• Voltage • 0 V DC to +10 V DC, 1 to 5 V, 0 Input voltage option 2 12 to 36 V DC; 12 to 24 V AC, 6 W
to 5 V max.
• Thermocouple temperature • Type J: -50 to +750 °C Transmitter power supply One or two isolated transmitter
(-58 to +1382 °F) power supplies (optional)
• Type K: -50 to +1260 °C - Single power supply: • One 24 V DC ±10% @ 200 mA
(-58 to +2300 °F) max.
• Type E: -50 to +870 °C - Dual power supplies: • One 24 V DC ±10% @ 200 mA
(-58 to +1578 °F) maximum, and one 24 V DC
• Type T: -180 to +371 °C ±10% @ 40 mA maximum
(-292 to +700 °F) External loop power supply 35 V DC max.
• Type T, 0.1° Resolution: -180.0
to +371 °C (-199.9 to +700 °F) Output loop resistance • 24 V DC, 10 to 700 Ω max.

• RTD temperature • 100 Ω RTD: -200 to +750 ºC


(-328 to +1382 ºF)
• 35 V DC (external), 100 to
1200 Ω max. 5
Displays and controls
Output signal
• Display • 14 mm (0.56") high LED
• Output • PDC output
• Numeric range from -1999 to
• 4 to 20 mA (optional) +9999
• Modbus (optional) • Four digits, automatic lead zero
• Relays 2 SPDT Form C relays, rated 3 A blanking
@ 30 V DC or 3 A @ 250 V AC, • Eight intensity levels
non-inductive, auto-initializing
(optional) • Memory • Non-volatile
• Communications • RS-232 with PDC or Modbus • Stores settings for minimum of
RTU 10 years if power is lost
• RS-422/485 with PDC or Mod- • Programming • Primary: front panel
bus RTU • Secondary: Meter Copy or PC
Accuracy with SITRANS RD Software

• 4 to 20 mA optional output ±0.1% FS ±0.004 mA Certificates and approvals CE, UL, CUL

• Process input ±0.05% of span ±1 count, square Options


root: 10 to 100% FS • Enclosures Plastic, steel and stainless steel
• Thermocouple temperature input • Type J: ±1 °C (±2 °F) (Type 304, EN 1.4301) NEMA 4
and 4X enclosures
• Type K: ±1 °C (±2 °F)
• Communications Modbus RTU
• Type E: ±1 °C (±2 °F)
®
• Type T: ±1 °C (±2 °F) Modbus is a registered trademark of Schneider Electric.
®
Belden is a registered trademark of Belden Wire and Cable Company.
• Type T, 0.1° Resolution: ±1 °C
(±1.8 °F)
• RTD temperature input • 100 Ω RTD: ±1 °C (±1 °F)
Rated operating conditions
Ambient conditions
Operating temperature range 0 to +65 ºC (+32 to +149 ºF)
Design
Weight 269 g (9.5 oz) (including options)
Material (enclosure) • 1/8 DIN, high impact plastic,
UL94V-0, color: gray
• Optional plastic, steel and stain-
less steel (Type 304, EN 1.4301)
NEMA 4 enclosures
Degree of protection Type 4X, NEMA 4X, IP65 (front
cover); panel gasket provided

March 2009 Siemens FI 01 · 2009 US Edition 5/295


© Siemens AG 2009

Level instruments
Communications and Displays
SITRANS RD200

Selection and Ordering data Order No. Selection and Ordering data Order No.
SITRANS RD200 C) 7 M L 5 7 4 0 - SITRANS RD200 C) 7 M L 5 7 4 0 -
A universal input, panel mount remote digital dis- 77 7 77 - 0 A A universal input, panel mount remote digital dis- 77 7 77 - 0 A
play for process instrumentation. play for process instrumentation.
Input voltage Accessories
85 to 265 V AC, 50/60 Hz; 90 to 265 V DC, } 1 SITRANS RD200 copy cable 2.1 m (7 ft) C) 7ML1930-1BR
20 W max. SITRANS RD200 RS-232 serial adapter (copy C) 7ML1930-1BS
12 to 36 V DC; 12 to 24 V AC, 6 W max. 2 cable included)
Transmitter supply SITRANS RD200 RS-422/485 serial adapter (copy C) 7ML1930-1BT
cable included)
None A
RS-232 to RS-422/485 isolated converter C) 7ML1930-1BU
Single 24 V DC transmitter supply1) } B
RS-232 to RS-422/485 non-isolated converter C) 7ML1930-1BV
Dual 24 V DC transmitter supply1) 2) C
SITRANS RD200 RS-232 and RS-485 isolated C) 7ML1930-1BW
Output multi-input adapter board
None } A USB to RS-422/485 isolated converter C) 7ML1930-1BX
2 relays B USB to RS-422/485 non-isolated converter C) 7ML1930-1BY
4 to 20 mA output C USB to RS-232 converter C) 7ML1930-1DC
Communication RD Software CD for 1 to 100 displays C) 7ML1930-1CC
Modbus disabled } 0 Modbus option enabled 7ML1930-1CD
Modbus enabled 1 Low cost polycarbonate plastic enclosure for C) 7ML1930-1CF
1 display
Approvals Thermoplastic enclosure
CE, UL, CUL 1 For use with 1 display C) 7ML1930-1CG
Instruction manual For use with 2 displays C) 7ML1930-1CH
5 English
German
C) 7ML1998-5JS01
C) 7ML1998-5JS31
For use with 3 displays
For use with 4 displays
C)
C)
7ML1930-1CJ
7ML1930-1CK
Note: The instruction manual should be ordered as For use with 5 displays C) 7ML1930-1CL
a separate line item. For use with 6 displays C) 7ML1930-1CM
This device is shipped with the Siemens Milltronics Stainless steel enclosure (Type 304, EN 1.4301)
manual CD containing ATEX Quick Starts and For use with 1 display C) 7ML1930-1CN
instruction manuals.. For use with 2 displays C) 7ML1930-1CP
Other Instruction manuals For use with 3 displays C) 7ML1930-1CQ
SITRANS RD Enclosures, English C) 7ML1998-5JX01 For use with 4 displays C) 7ML1930-1CR
SITRANS RD Enclosures, German C) 7ML1998-5JX31 For use with 5 displays C) 7ML1930-1CS
SITRANS RD Serial Adapters, English C) 7ML1998-5JV01 For use with 6 displays C) 7ML1930-1CT
SITRANS RD Serial Adapters, German C) 7ML1998-5JV31 Steel enclosure
SITRANS RD Software, English C) 7ML1998-5JW01 For use with 1 display C) 7ML1930-1CU
SITRANS RD Software, German C) 7ML1998-5JW31 For use with 2 displays C) 7ML1930-1CV
For use with 3 displays C) 7ML1930-1CW
For use with 4 displays C) 7ML1930-1CX
For use with 5 displays C) 7ML1930-1CY
For use with 6 displays C) 7ML1930-1DA
1)
Available with input voltage option 1 only
2) Available with output option C only
C) Subject to export regulations AL: N, ECCN: EAR99
} Available ex stock when configured with the following options only: Input
voltage: 1, Transmitter supply: B, Output : A, Communication: 0.

5/296 Siemens FI 01 · 2009 US Edition March 2009


© Siemens AG 2009

Level instruments
Communications and Displays
SITRANS RD200

■ Dimensional drawings

5
SITRANS RD200 dimensions

■ Schematics

SITRANS RD200 connections

March 2009 Siemens FI 01 · 2009 US Edition 5/297


© Siemens AG 2009

Level instruments

5/298 Siemens FI 01 · 2009 US Edition March 2009

You might also like