3AK6 Vacuum Circuit Breaker The Right Choice for varied tasks
Advantage of Vacuum over Salient features of 3AK6
other interrupting media: Vacuum Circuit Breaker • Highest dielectric strength • Conforms to IEC 62271- over a small contact gap 100/Latest IS standards • Constant low contact and is fully type tested resistance. • Simple and compact • Fastest recovery design strength. • Interrupters housed • Lowest arc energy inside a enclosed dissipation insulated pole • Lowest drive energy • Totally restrike free requirements • Suitable for rapid auto • Minimum contact erosion reclosing • No fire hazards or • Highly reliable operation explosion risks • Long maintenance free Construction • VCB has least number of life The 3AK6 compact and reliable moving parts and hence • High switching capability vacuum circuit breakers consist highest reliability • Fully established for all of three poles incorporating the applications vacuum interrupters housed in • Matching drive and insulated shell. These poles are interrupter characteristics then covered via a insulated • Best suited for all medium pole cover from behind to make voltage applications the design completely enclosed. The moving contacts of the vacuum interrupter are Switching application connected to the drive 3AK6 VCB is very well mechanism through insulated suitable for all medium connecting rods. Operating voltage applications e.g. mechanism is of stored energy switching of motors, type and suitable for auto transformers, capacitors, reclosing duty. The operation cables, overhead lines and can be manual/electrical as other industrial loads desired.
Maintenance free Environmental compatibility
The 3AK6 vacuum circuit 3AK6 vacuum circuit breakers breakers are truly are environment friendly with maintenance free with respect to material selection and new generation manufacturing methods and interrupters from have no effect on the Siemens. The heart of the environment during and after the drive mechanism i.e. the switching operations. It is easy gear box is also sealed to dispose off at the end of its and lubricated for life. service life. The drive mechanism is free of chain snapping problem of conventional VCBs Technical Data 3AK6 Vacuum Circuit Breaker Rated Voltage upto 12kV One minute power frequency withstand 28kV* voltage (rms) 1.2/50 micro second lightening impulse 75kVp* withstand voltage Rated current upto 3150A Short Time Withstand current (3 sec) 40/44kA Short Circuit Breaking current 40/44kA Rated making capacity 100/110kAp Rated Operating sequence O-3min-CO-3min-CO Single capacitor bank breaking current 400A Cable charging breaking current 50A Guaranteed number of operations at 10,000 (E2/M2 Class) rated current Capacitor current switching class C2 Is CB restrike free Yes Type of operating mechanism Motor Spring Reserve Drive ( M.S.R.D)