IMAX 350.

713
Pumpe/pump
FC CATALOG NO: 20AC8P7C3AYNANC0
FC SERIAL NO: 13041270

File Group Parameter Name No. Default Value User


MOTOR Motor Data Motor NP Volts 41 Drive Rating Based 400 V
CONTROL Motor NP FLA 42 Drive Rating Based 8.4 A
(File B) Motor NP Hertz 43 Drive Rating Based 50 Hz
Motor NP RPM 44 Drive Rating Based 2900 RPM
Motor NP Power 45 Drive Rating Based 4,0 KW
Mtr NP Pwr Units 46 0 (Horsepower) 1 (kiloWatts) 3. step
Motor Poles 49 4 2
Momentattribute Torque Perf Mode] 53 0 (Sensrls Vect) 3 (Fan/Pmp V/Hz)
Maximum Voltage 54 Drive Rated Volts 400 V

V/Hz StAcc Boost 69 Drive Rating Based


Run Boost 70 Drive Rating Based
Break Voltage 71 [Motor NP Volts] × 0.25
Break Frequency 72 [Motor NP Hertz] × 0.25

SPEED Spd Mode Minimum Speed 81 0.0 Hz 19 Hz


COMMAND & Limits Maximum Speed 82 50.0 or 60.0 Hz 60 Hz
(File C) Speed Speed Ref A Sel 90 2 (Analog In 2)
References Speed Ref A Hi 91 Maximum Speed 60 Hz
Speed Ref A Lo 92 0.0 Hz 19 Hz
Speed Ref B Hi 94 Maximum Speed
TB Man Ref Hi 97 Maximum Speed
Discrete Preset Speed 3 103 20.0 Hz
Speeds Preset Speed 7 107 60.0 Hz
Speed Trim Trim Hi 119 50.0 Hz

DYNAMIC Ramp Rates Accel Time 1 140 10.0 Secs 1.0 Secs
CONTROL Decel Time 1 142 10.0 Secs 1.0 Secs
(File D) Load Limits Current Lmt Val 148 [Rated Amps] × 1.5
Stop/Brake Stop Mode B 156 0 (Coast)
Modes DB Resistor Type 163 2 (None) 0 (Internal Res)
Power loss Power Loss Mode 184 0 (Coast)

UTILITY Direction Config Direction Mode 190 0 (Unipolar)


(File E) HIM Ref Config Save MOP Ref 194 xxxx xxxx xxxx xx00
MOP Rate 195 1.0 Hz/s
Param Access Lvl 196 0 (Basic) 1 (Advanced) 1. step
Reset To Defalts 197 0 (Ready) 3 (High Voltage) 2. step

INPUTS Analog Inputs Analog In 2 Lo 326 0.000 Volt


& OUTPUTS Digital Inputs Digital In1 Sel 361 4 (Stop – CF) 0 (Not Used)
(File J) Digital In2 Sel 362 5 (Start) 7 (Run)
Digital In3 Sel 363 18 (Auto/ Manual) 2 (Clear Faults)
Digital In4 Sel 364 15 (Speed Sel 1)
Digital In5 Sel 365 16 (Speed Sel 2)
Digital In6 Sel 366 17 (Speed Sel 3) 1 (Enable)
Digital Outputs Digital Out1 Sel 380 1 (Fault) 3 (Ready)
Digital Out2 Sel 384 4 (RUN)
Dig Out2 Level 385 0.0