You are on page 1of 12

See discussions, stats, and author profiles for this publication at: https://www.researchgate.

net/publication/235396177

Elastomeric chain force decay in artificial saliva: An in vitro study

Article  in  International orthodontics · January 2013


DOI: 10.1016/j.ortho.2012.12.007 · Source: PubMed

CITATIONS READS

5 423

5 authors, including:

Abdelali Halimi Khalil El Mabrouk


Mohammed V University of Rabat Euromed University of Fes
23 PUBLICATIONS   36 CITATIONS    40 PUBLICATIONS   391 CITATIONS   

SEE PROFILE SEE PROFILE

Fatima Zaoui
Université Mohammed V de Rabat (UM5R)
110 PUBLICATIONS   253 CITATIONS   

SEE PROFILE

Some of the authors of this publication are also working on these related projects:

Gouttières orthodontiques et résorption radiculaire : revue systématique View project

Orthodontics View project

All content following this page was uploaded by Khalil El Mabrouk on 12 October 2017.

The user has requested enhancement of the downloaded file.


Ó 2013 CEO
Published by / Édité par Elsevier Masson SAS

Original article All rights reserved / Tous droits réservés

Article original

Elastomeric chain force decay in artificial


saliva: An in vitro study
gradation de la chaı̂nette e
De lastome
rique dans la
tude in vitro
salive artificielle : e

Abdelali HALIMIa,*, Mohamed-Faouzi AZEROUALa, Anas DOUKKALIb,


Khalid EL MABROUKc, Fatima ZAOUIa
a
Oral biomechanics and biotechnology research unit, University Mohammed V, Souissi (UM5S),
College of dental medicine, Ibn Sina Hospital Center, Dentofacial orthopedics department,
BP 6212, Rabat, Morocco
b
Analytical chemistry laboratory, University Mohammed V, Souissi (UM5S), College of
medicine and pharmacy, BP 6212, Rabat, Morocco
c
MASCIR Foundation (Science Marocaine Avancee, Recherche et Innovation), INANOTECH
(Institut des nanomateriaux et des nanotechnologies), ENSET avenue Royale de l’Armee,
Madinat El Irfane, Rabat, Morocco

Available online: 31 January 2013 / Disponible en ligne : 31 janvier 2013

Summary sume
Re 
Introduction: The main objective of this study was to reexamine Introduction: L’objectif principal de cette etude  est de
the mechanical properties of elastomeric chains after stretching reetudier
 les propriet  es
 
mecaniques des chaıˆnettes
in various artificial saliva solutions and in air. 
elastom 
eriques  etirement
apres  
dans differentes solutions
de salive artificielle et dans l’air ambiant.
Materials and methods: Five brands of elastomeric chain man- 
Materiels 
et methode: Cinq marques de chaıˆnettes
ufactured by different companies were selected. For each brand, 
elastom 
eriques fabriquees par des societ  es
 differentes
 ont
four types were tested in different artificial media. A dismoun-  e selectionn
et   pour l’etude
ees  ; pour chaque marque quatre
table test kit was used to stretch the chains up to various initial types ont et  e testes
 dans differents
 milieux artificiels. Les
force levels. They were then immersed in pre-prepared solutions, chaıˆnettes ont et e etir
 ees à l’aide d’un kit demontable
 jusqu’à
with control samples exposed to air only. Residual force was 
atteindre differents niveaux de force initiale, puis immergees 
measured at multiple time points using a hand-held dans les solutions prepar  ees  tout en gardant un echantillon

dynamometer. 
temoin dans l’air. La force residuelle a et e mesuree 

à differentes reprises avec un dynamometre  manuel.
Results and discussion: The force delivered by the elastomeric 
Resultats et discussion: La force liber  ee
 par la chaıˆnette
chains decayed rapidly and differently over time. This decay 
elastom 
erique 
subit une degradation 
rapide et differente dans
varied depending on multiple factors, discussed here. le temps. Cette variabilite de la degradation
 est fonction de
plusieurs facteurs qui sont discutes. 
Ó 2013 CEO. Published by Elsevier Masson SAS. All rights Ó 2013 CEO. Édité par Elsevier Masson SAS. Tous droits
reserved réservés

* Correspondence and reprints / Correspondance et tires à part :


Abdelali HALIMI, Lotissement Wifak 1, immeuble 1422, appartement 20, Tamara,
Morocco.
e-mail address / Adresse e-mail : halimiali111@yahoo.fr

60 International Orthodontics 2013 ; 11 : 60-70


doi:10.1016/j.ortho.2012.12.007
Elastomeric chain force decay in artificial saliva: An in vitro study
gradation de la chaı̂nette e
De lastome
rique dans la salive artificielle : e
tude in vitro

Key-words s
Mots-cle
·· Elastomeric chains.
Biodegradation.
·· Chaı̂nette e
Biode
lastome
gradation.
rique.

·· Biomechanics.
Tooth movement.
·· Biome
De
canique.
placement dentaire.
·· Orthodontics.
In vitro study.
·· Orthodontie.

Etude in vitro.

Introduction Introduction

Elastomeric chains are indispensable tools. They generate a La chaı̂nette est un outil incontournable, elle ge nere en partie
part of the force needed to move teeth during leveling–align- la force du de placement dentaire des phases d’alignement/
ing–derotating, canine/incisor retraction, space closure, mid- nivellement, de la correction des rotations, des re  tractions
line correction, orthodontic retention, mesial displacement of canine et incisive, de la fermeture des espaces, de la correc-
the posterior quadrants, and traction of impacted teeth (fig. 1). tion des me dianes, du maintien des dents entre elles, de la
The way they behave inside the mouth, however, differs widely me sialisation des secteurs poste rieurs et de la traction des
depending on the circumstances. dents incluses (fig. 1). Cependant, en milieu buccal, son
comportement diffe re selon les situations.
Elastomeric chains come in different types: open (short/long) Les chaı̂nettes e lastomeriques existent sous diffe rentes for-
and closed. They can be transparent, gray, or other-colored. mes : chaı̂nettes à modules serre s, chaı̂nettes à modules
rapproche s et chaı̂nettes à modules espace s. Elles peuvent
^tre transparentes, grises, ou de diffe
e rentes couleurs.
Changes in the amount of force they deliver over time lead to L’instabilite de la force qu’elle libe re dans le temps engendre
therapeutic control problems that can affect their clinical des proble mes du contro ^ le therapeutique pour son efficacite 
efficacy and efficiency. It is also sometimes difficult to choose et son efficience clinique. La diversite  de l’offre commerciale
from among the many different products available. engendre un proble me de choix judicieux de cet outil.
Several studies (Table I) have reported chains losing 50–75% Plusieurs e tudes (Tableau I) rapportent que la chaı̂nette pour-
of their initial force on the first day of use, and then continuing rait perdre de 50 à 75 % de sa force initiale pendant le premier
to decay exponentially. This decay is due to intra-oral expo- jour d’application ; ensuite elle continue à se de grader d’une
sure, mastication, oral hygiene, salivary enzymes, and varia- façon exponentielle. Cette de gradation s’explique par l’expo-
tions in intra-oral temperature, which may accelerate the sition intra-orale, l’effet de la mastication, l’hygie ne orale, les
aging of the chain in vivo. enzymes salivaires et la variation de la tempe rature buccale
qui peut acce  le
rer son vieillissement in vivo.
The main goal of this study was to assess the decay in the force L’objectif principal de ce travail est d’e tudier la de
gradation de
delivered by elastomeric chains after stretching and exposure la force libe  re
e par des chaı̂nettes e lastome riques apre s
to various media, namely, artificial saliva of different pH tirement et exposition dans des milieux diffe
e rents : une salive
levels and air. artificielle avec des PH diffe rents et l’air ambiant.
We also had three secondary objectives: Ce travail a e galement trois objectifs secondaires :
— to compare force decay in open and closed chains; — comparer les de gradations de la chaı̂nette serre e et de la
chaı̂nette espace e ;
[(Fig._1)TD$IG]

Fig. 1: Some clinical applications of elastomeric chains in orthodontics: a: canine retraction; b: space closure; c: correction of incisor midlines.
 lastome
Fig. 1 : Applications cliniques de la chaı̂nette e  rique en orthodontie : a : re
 traction canine ; b : fermeture d’espaces ; c : correction des
lignes medianes incisives.

International Orthodontics 2013 ; 11 : 60-70 61


Abdelali HALIMI et al.

Table I Tableau I
List of studies relevant to force decay over time. Liste des etudes qui s’inte
ressent à la de
gradation de la force
 re
libe e dans le temps.


Force decay over time/Degradation  ee
de la force liber  dans le temps
Andreasen 1970 AO Unitek C-1 alastik modules and latex elastics/Unitek C-1 modules alastik et

elastiques en latex
Hershey 1975 AJO Unitek C-1 alastik modules, Ormco Power Chain, TP Elast-O-Chain/Unitek C-1
modules alastik, Ormco Power Chain, TP Elast-O-Chain
Wong 1976 AO Unitek C-1 alastik modules, Ormco power chain/Unitek C-1 modules alastik, Ormco
power chain
Kovatch 1976 JDR Unitek C-1 alastik modules/Unitek C-1 modules alastik
Ash 1978 JDR Unitek C-1 alastik modules/Unitek C-1 modules alastik
Brantley 1979 AO Unitek C-1 alastik modules, Ormco Power Chain II/Unitek C-1 modules alastik,
Ormco Power Chain II
De Genova 1985 AJO Ormco Power Chain II, Rocky mountain Energy chain, TP Elast-O-Chain
Rock 1985 BJO 
13 different types of chain/13 types de chaıˆnettes differentes
Killiany 1985 JCO Rocky Mountain Energy Chain/
Kuster 1986 EJO Unitek C-1 alastik modules, Ormco Power Chain II/Unitek C-1 modules alastik,
Ormco Power Chain II
Baty 1992 IP Unitek C-1 alastik modules, Ormco Power Chain II and Masel colored chains/
 Masel
Unitek C-1 modules alastik, Ormco Power Chain II et chaıˆnettes colorees
Eliades 2003 HOR 
Open and closed chain types (ORMCO)/Types de chaıˆnettes elastom 
eriques
 (ORMCO)
ouvertes et serrees
Chimenti 2001 PO 
6 different types of elastomeric chain, total of 312 chains/6 differents types de

chaıˆnettes elastom 
eriques 
sur un total de 312 chaıˆnettes elastom 
eriques
Eliades 2005 JOR 3 polyurethane elastomeric modules (Generation II, Dentaurum, Alastic)/3 modules

elastom 
eriques 
en polyurethane (Generation II, Dentaurum, Alastic)
Eliades 2004 EJO 2 types (open and closed, with and without link) from three brands of elastomeric

module/2 types (chaıˆnettes ouvertes et serrees, avec et sans liaisons) de 3 marques

de modules elastom 
eriques
Storie 1994 AO Fluor-I-Chain, standard gray elastomeric chain/Fluor-I-Chain, chaıˆnettes

elastom 
eriques grises standards
Stevenson 1993 AJO-DO 
Transparent and gray elastomeric chains/Chaıˆnettes elastom 
eriques transparentes
et grises
Renick 1994 AO 3 polyurethane-based elastomeric chains (Nihon, Pellethane, Texin)/3 chaıˆnettes

elastom 
eriques 
à base de polyurethane (Nihon, Pellethane, Texin)
Sang 2004 AJO-DO 3 different-colored chains (gray, red, and purple) from 3 manufacturers (RMO, Ormco

and G&H)/3 differentes  (grise, rouge et violet) de 3 fabricants
chaıˆnettes colorees
(RMO, Ormco et G&H)
Blahs 2008 SKQYX Chains of different filament types and numbers of loops, specific initial force/

Chaıˆnettes de differents types de filament et de nombres de boucles, et dont la force

initiale est definie
Chau Lu 2011 JO Closed (non-spaced), gray elastomeric chains from 4 companies/Serree  (sans

espaces), chaıˆnettes elastom 
eriques grises de 4 fournisseurs
AO: angle orthodontist; AJO: American journal of orthodontists; JCO: Journal of clinical orthodontics; EJO: European journal of orthodontics; BJO: British journal of orthodontics; JDR: Journal
dental research; AJO-DO: American journal of orthodontics and dentofacial orthopedics; HOR: Hellenic orthodontic review; PO: Progress in orthodontics; JOR: Journal of oral rehabilitation; JMS:
Journal of materials science: materials in medicine; BOR: Brazilian oral research; OCR: Orthodontics & craniofacial research; SKQYX: Shanghai Kou Qiang Yi Xue; JCDP: The journal of
contemporary dental practice; JCPD: The journal of clinical pediatric dentistry; PNSCRC: Proceedings of the national science council, Republic of China; JO: Journal of orthodontics; OW:
orthodontic waves; PC: personnel communication; IP: in press.

— to compare force decay in gray and transparent chains; — comparer les de gradations de la chaı̂nette grise et de la
chaı̂nette transparente ;
— to compare force decay in all five brands of chain. — comparer les de gradations de la force ge
ne
 re
e par les cinq
marques de chaı̂nettes.

62 International Orthodontics 2013 ; 11 : 60-70


Elastomeric chain force decay in artificial saliva: An in vitro study
gradation de la chaı̂nette e
De lastome
rique dans la salive artificielle : e
tude in vitro

Materials and methods riel et me


Mate thodes

We studied five brands of polyurethane chain marketed by Cinq marques de chaı̂nettes en polyure  thane
different companies (GAC, RMO, Ortho-Organizers Inc., commercialise es par des socie  te
s differentes (GAC, RMO,
G&H, Generation II). For each brand, two distinct colors Ortho-Organizers Inc, G&H, Ge  ne
ration II) ont e te
 choisies
(gray/clear) and two chain types (open/closed) (Table II, tude. Pour chaque marque, deux couleurs diffe
pour l’e rentes
fig. 2) were tested in various media: air and artificial saliva (grise/claire) et deux types diffe rents (serre /espace )
at different pH levels (pH 7, pH 4, and pH 2.5). The saliva  te
(Tableau II, fig. 2) ont e  testes dans diffe rents milieux : l’air
formula used for this study was Saliveze [1,2], a therapeutic rents niveaux de pH : pH7,
ambiant et la salive artificielle à diffe
artificial saliva whose properties are close to those of real pH4 et pH2,5. La formule de la salive utilise e dans notre e tude
human saliva (Table III). correspond à la saliveze [1,2] : une salive artificielle the rapeu-
tique qui se rapproche de la salive humaine (Tableau III).
Each chain segment was stretched to an initial force of roughly Chaque segment subit un e tirement jusqu’à atteindre une
200 g as measured using a hand-held dynamometer (fig. 3). force initiale d’environ 200 g dose e à l’aide d’un dynamome tre
The segments were then maintained in their stretched position manuel (fig. 3). Ensuite, chaque segment est garde e tire
 entre
between two sliding hooks 35 mm apart (standard distance for deux crochets coulissants se pare s de 35 mm (distance habi-
classic canine retraction) and immersed for 6 weeks airtight tuelle pendant un recul canin classique) et est immerge  pen-
containers filled with saliva. dant six semaines dans la salive dans des boı̂tes e tanches.

Table II Tableau II
Chains under study. rentes chaı̂nettes e
Diffe value
es dans l’e
tude.

Code (type) Company/Societ e Color/Couleur Type


I GAC
II  eration
Generation II/Gen  II
III Ormco Gray, transparent/Grise, transparente  serree
Open, closed/Espacee, 
IV Ortho-Organiser
V G&H

[(Fig._2)TD$IG]

Fig. 2: The different types of elastomeric chain under study (a: types I, II, III, IV, V, and b: long, closed, short in various colors).
rents types de chaı̂nettes e
Fig. 2 : Diffe lastome
 riques e
 tudie
 es dans l’e
 tude (a : types I, II, III, IV, V et b : modules espace
 , serre
, rapproche
 avec
couleurs varie es).

International Orthodontics 2013 ; 11 : 60-70 63


Abdelali HALIMI et al.

Table III Tableau III


Saliveze formula, borrowed from Preetha and Banerjee e à Preetha et
Formule de la saliveze : composition emprunte
2005 [2]. Banerjee, 2005 [2].

Component/Composantes Quantity en g/L/Quantite en g/L


Sodium carboxymethylcellulose 10
Potassium chloride 0.62
Sodium chloride 0.87
Magnesium chloride 0.06
Calcium chloride 0.17
Di-potassium hydrogen orthophosphate 0.80
Potassium di-hydrogen orthophosphate 0.30
Sodium fluoride 0.0044
Sorbitol 29.95
Methyl p-hydroxybenzoate 1.00
Spirit of lemon 5 mL

Chain force measurements were performed using a manual Les mesures de la force libe  re
e par les diffe
rentes chaı̂nettes
dynamometer at time point zero (initial force H0), 1 hour ont e  te
 re
alise
es dans un premier temps à l’aide d’un dyna-
(H1), 12 hours (H12), 24 hours (H24), 2 days, 2 days, 4 days, mome tre manuel, à diffe rentes reprises : au de part (force
6 days, 2 weeks, 3 weeks, 4 weeks, 5 weeks, and 6 weeks. initiale H0), apre s une heure (H1), apre s 12 heures (H12),
Measurements were retaken using an Instron 88215 device apre s 24 heures (H24), apre s deux jours, apre s trois jours,
so as to gauge the dynamometer’s validity. apre s quatre jours, apre s six jours, apres deux semaines,
apre s trois semaines, apre s quatre semaines, apre s cinq
semaines et apre s six semaines. Dans un deuxie me temps,
les mesures ont refaites à l’aide de l’appareil Instron
88215 pour juger de la validite  du premier outil.
Lastly, representative samples were analyzed under a scan- Finalement, une analyse au microscope e lectronique à balay-
ning electron microscope (SEM) to compare the chains’ micro- age (MEB) d’e chantillons representatifs a e te
 re
alise
e pour
scopic features before and after stretching. comparer l’e tat microscopique des diffe rentes chaı̂nettes
avant et apre s e
tirement.

Results sultats
Re

The results of this study showed that the force delivered by the Les re sultats de notre e tude montrent que la force libe  re
e par
various chains decayed rapidly and continuously over time, les differentes chaı̂nettes e tudie
es se de grade rapidement
both in air and in artificial saliva. This decay varied depend- avec le temps et d’une façon continue ; cela aussi bien dans
ing on the pH of the test medium: the more acidic the pH, the l’air ambiant que dans la salive artificielle. Cette de gradation
greater the force decay (fig. 4). varie en fonction du pH du milieu d’e tude : plus le pH est acide,
plus la de gradation est importante (fig. 4).
In artificial saliva with a pH of 7 and a temperature of 37 , the Dans la salive artificielle pH 7 à 37 , la chaı̂nette transparente
clear chain decayed more rapidly than the gray chain (fig. 5). se de grade plus rapidement que la chaı̂nette grise (fig. 5). La
The closed chain decayed less quickly than the open chain chaı̂nette serre e se de grade moins vite que la chaı̂nette
(fig. 6). The different chain types under study decayed differ- espace e (fig. 6). Les types de chaı̂nettes e tudie es se
ently in saliva, and can easily be ranked in ascending order degradent diffe remment dans la salive et on peut tre s vite
accordingly: type III, type I, type II, type IV, and lastly type V les classer dans l’ordre de de gradation croissant suivant : type
(fig. 7). III, type I, type II, type IV et enfin le type V (fig. 7).
Microscopic analysis of types V and I in their initial states L’analyse microscopique des type V et I, à l’e tat initial, montre
showed a rectilinear structure for type V and a more fibrous, une structure de fibres rectilignes pour le type V et une struc-
crisscross structure for type I (fig. 8). ture pluto^t fibreuse pour le type I dont les fibres sont oriente es
d’une manie re differente (fibres croisees) (fig. 8).

64 International Orthodontics 2013 ; 11 : 60-70


Elastomeric chain force decay in artificial saliva: An in vitro study
gradation de la chaı̂nette e
De lastome
rique dans la salive artificielle : e
tude in vitro

[(Fig._3)TD$IG]

Fig. 3: a–d: adjustable stretch kit with hooks 35 mm apart; initial and subsequent force measurements were made under the same conditions.
 tirement re
Fig. 3 : a–d : kit d’e glable, la distance entre crochets est fixe
e à 35 mm ; la force libe
re
e est mesure
 e initialement et à diffe
rents reprises
en respectant les me ^mes conditions de mesures.

After 6 weeks’ stretching in air for type V (the type with the Apres six semaines d’e tirement dans l’air pour le type V (le
most force decay), SEM revealed faint uniform surface distor- plus degrade), nous constatons au MEB une alte ration de
tions located on and between the modular rings. However, surface faible et homoge ne localisee aussi bien dans le
after 6 weeks’ stretching in artificial saliva at pH 7, we nœud que dans l’internœud ; mais apre s six semaines
detected major surface distortion in the form of a large crack tirement dans la salive artificielle à pH7, nous constatons
d’e
located in the inter-modular link area (fig. 9). Acid damage ration de la surface mate
une forte alte rialisee par une fissure
from the test medium and stretching effects were less visible in importante localisee au niveau de la zone de l’internœud (fig.
type I (less decay), microscopic analysis of which showed a few 9). L’attaque du milieu acide et l’effet d’etirement sont moins
torn fibers in the inter-modular link area (fig. 10). visibles sur le type I (moins degrade ) et son analyse micro-
scopique montre un de chirement de quelques fibres dans la
zone de l’internœud (fig. 10).

International Orthodontics 2013 ; 11 : 60-70 65


Abdelali HALIMI et al.

[(Fig._4)TD$IG]

Fig. 4: Compared effects of test medium on chain force decay.


 gradation de la
Fig. 4 : Comparaison des effets du milieu sur la de
chaı̂nette.

[(Fig._5)TD$IG]

Fig. 5: Compared force decay in gray and transparent chains in saliva


at 37 , pH 7.
Fig. 5 : Comparaison de la de gradation des chaı̂nettes grise et transpar-
ente dans la salive 37 , pH7.

[(Fig._6)TD$IG]

Fig. 6: Compared force decay in closed and open chains in saliva at


37 , pH 7.
Fig. 6 : Comparaison de la de gradation des chaı̂nettes serre
e et
espacee dans la salive 37 , pH 7.

66 International Orthodontics 2013 ; 11 : 60-70


Elastomeric chain force decay in artificial saliva: An in vitro study
gradation de la chaı̂nette e
De lastome
rique dans la salive artificielle : e
tude in vitro

[(Fig._7)TD$IG]

Fig. 7: Compared force decay in the five chain types in saliva at 37 ,
pH 7.
Fig. 7 : Comparaison de la de  gradation de la force des 5 types de
chaı̂nettes dans la Salive 37 , pH7.

[(Fig._8)TD$IG]

Fig. 8: Microscopic analysis of type V, and type I in initial state.


 tat initial.
Fig. 8 : Analyse microscopique du type V, et du type I à l’e

Discussion Discussion

The force delivered by the elastomeric chains decayed rapidly La force libe  re
e par la chaı̂nette e lastome rique subit une
and to a greater extent in artificial saliva versus air. degradation rapide, plus importante dans la salive artificielle
que dans l’air ambiant.
Nattrass et al. [3] have reported greater force decay in elasto- Nattrass et al. [3] ont constate une deperdition de la force des
meric chains in cola and curcuma than in water. Kuster et al. chaı̂nettes elastomeriques plus importante dans le cola et le
[4] have demonstrated that force decay is greater in vivo than curcuma que dans l’eau. Kuster et al. [4] ont montre  que cette
in air. Ash and Nicolai [5] have reported greater force decay in degradation de la force est plus importante in vivo que dans
vivo than in vitro. l’air ambiant. Ash et Nicolai [5] ont reconnu que ce phe nomene
de de gradation de la force est plus important in vivo qu’in vitro.
Conversely, Eliades et al. [6,7] found no significant difference À l’inverse, Eliades et al. [6,7] ont montre  qu’il n’y a pas de
in tensile strength between chains stretched in air and intra- difference significative en ce qui concerne la re sistance à la
orally. traction entre des chaı̂nettes e tire
es à l’air et en bouche.
Force decay differed depending on the chain, varying on La de gradation est diffe
rente en fonction de la chaı̂nette ; elle
average from 56% to 91% after 4 weeks. The open chains varie en moyenne de 56 à 91 % apre s quatre semaines. La

International Orthodontics 2013 ; 11 : 60-70 67


Abdelali HALIMI et al.

[(Fig._9)TD$IG]

Fig. 9: Microscopic analysis of type V in its initial state and after 6 weeks’ stretching in air and
artificial saliva.
tat initial et apre
Fig. 9 : Analyse microscopique du type V à l’e s 6 semaines d’e
tirement dans l’air
et dans la salive artificielle.

[(Fig._10)TD$IG]

Fig. 10: Microscopic analysis of type I in its initial state and after 6 weeks’ stretching in air and
artificial saliva.
tat initial et apre
Fig. 10 : Analyse microscopique du type I à l’e s 6 semaines d’e
tirement dans l’air
et dans la salive artificielle.

68 International Orthodontics 2013 ; 11 : 60-70


Elastomeric chain force decay in artificial saliva: An in vitro study
gradation de la chaı̂nette e
De lastome
rique dans la salive artificielle : e
tude in vitro

decayed more rapidly than closed ones, transparent chains chaı̂nette espace e se de grade plus rapidement que la
less rapidly than gray ones. chaı̂nette serree et la transparente moins vite que la grise.
Ash and Nicolai [5] have joined others [8–27] in reporting an Ash [5] s’accorde avec d’autres auteurs [8–27] pour dire que la
average loss of 50–85% of initial force after 4 weeks, depend- chaı̂nette perd en moyenne de 50 à 85 % de sa force initiale
ing on the chain and the study. au bout de quatre semaines en fonction des diffe rentes
chaı̂nettes et des differentes etudes.
Eliades et al. [6,23,25] found that open chains exhibited Eliades et al. [6,23,25] ont trouve que les chaı̂nettes à modules
greater residual extension than closed ones, allegedly because espaces presentent des e longations residuelles plus impor-
of major extension in the inter-modular link areas. tantes que celles avec modules serre s ; cela serait dû à une
longation importante au niveau des re
e gions intermodulaires.

Conclusion Conclusion

The force delivered by elastomeric chains decayed rapidly La force libe  re


e par la chaı̂nette e lastome rique subit une
over time. This decay was greater in saliva than in air, and degradation rapide dans le temps ; cette de gradation est plus
depended on the chain. importante dans la salive que dans l’air ambiant ; elle est
differente en fonction de la chaı̂nette.
The results presented in this paper reflect the first stage of our Les re sultats exposes dans cette pre sentation constituent une
study. The second stage will investigate a larger sample and premie re e
tape de l’e
tude. La deuxie me e tape sera consacre e
measure variables using an Instron 88512 device. tude d’un e
à l’e chantillon plus large et à la mesure des diffe
r-
ents variables par l’Instron 88512.

Disclosure of interest claration d’inte


De re
^ts

The authors declare that they have no conflicts of interest Les auteurs de clarent ne pas avoir de conflits d’inte
 re
^ ts en
concerning this article. relation avec cet article.

References/References

1. Humphrey SP, Williamson RT. A review of saliva: normal composition, flow, and function. J
Prosthet Dent 2001;85(2):162–9.
2. Preetha A, Banerjee R. Comparison of artificial saliva substitutes. Trends Biomater Artif
Organs 2005;8(2):178–86.
3. Nattrass C, Ireland AJ, Sherriff M. The effect of environmental factors on elastomeric chain
and nickel titanium coil springs. Eur J Orthod 1998;20(2):169–76.
4. Kuster R, Ingervall B, Burgin W. Laboratory and intra-oral test of the degradation of elastic
chains. Eur J Orthod 1986;8(3):202–8.
5. Ash JL, Nikolai RJ. Relaxation of orthodontic elastomeric chains and modules in vitro and
in vivo. J Dent Res 1978;57(5–6):685–90.
6. Eliades T, Gioka C, Zinelis S, Makou M. Study of stress relaxation of orthodontic elasto-
mers: pilot method report with continuous data collection in real time. Hell Orthodon Rev
2003;6(1):13-26.
7. Eliades T, Eliades G, Silikas N, Watts DC. Tensile properties of orthodontic elastomeric
chains. Eur J Orthod 2004;26(2):157–62.
8. Andreasen GF, Bishara SE. Comparison of alastik chains with elastics involved with intra-
arch molar to molar forces. Angle Orthod 1970;40(3):151–8.
9. Andreasen GF, Bishara SE. Relaxation of orthodontic elastic chains and midules in vitro
and in vivo. Angle Orthod 1970;40(3):151–8.
10. Hershey G, Reynolds W. The plastic module as an orthodontic tooth-moving mechanism.
Am J Orthod 1975;67(5):554–62.

International Orthodontics 2013 ; 11 : 60-70 69


Abdelali HALIMI et al.

11. Wong AK. Orthodontic elastic materials. Angle Orthod 1976;46(2):196-205.


12. Kovatch JS, Lautenschlager EP, Apfel DA, Keller JC. Load-extension-time behavior of
orthodontic alastiks. J Dent Res 1976;55(5):783–6.
13. Brantley W, Salander S, Myers L, Winders R. Effects of prestretching on force degradation
characteristics of plastic modules. Angle Orthod 1979;49(1):37-43.
14. De Genova DC, McInnes-Ledoux P, Weinberg R, Shaye R. Force degradation of orthodontic
elastomeric chains: a product comparison study. Am J Orthod 1985;87(5):377–84.
15. Rock W, Wilson H, Fisher S. A laboratory investigation of orthodontic elastomeric chains.
Br J Orthod 1985;12(4):202–7.
16. Killiany DM, Duplessis J. Relaxation of elastomeric chains. J Clin Orthod 1985;19(8):592–
3.
17. Baty DL, Storie DJ, von Fraunhofer JA. Synthetic elastomeric chains: a literature review.
Am J Orthod Dentofacial Orthop 1994;105(6):536–42.
18. Storie DJ, Regennitter F, von Fraunhofer JA. Characteristics of a fluoride releasing elas-
tomeric chain. Angle Orthod 1994;64(3):199-209 [discussion p. 210].
19. Lu TC, Wang WN, Tarng TH, Chen JW. Force decay of elastomeric chain: a serial study.
Part II. Am J Orthod Dentofacial Orthop 1993;104(4):373–7.
20. Stevenson JS, Kusy RP. Force application and decay characteristics of untreated and
treated polyurethane elastomeric chains. Angle Orthod 1994;64(6):455–64 [discussion
p. 465–7].
21. Renick MR, Brantley WA, Beck FM, Vig KW, Webb CS. Studies of orthodontic elastomeric
modules. Part 1: glass transition temperatures for representative pigmented products in the
as-received condition and after orthodontic use. Am J Orthod Dentofacial Orthop 2004;126
(3):337–43.
22. Sang T, Wu J. Factors on force degradation of elastomeric chains in vitro. Shanghai Kou
Qiang Yi Xue 2008;17(6):638–42.
23. Eliades T, Eliades G, Silikas N, Watts DC. In vitro degradation of polyurethane orthodontic
elastomeric modules. J Oral Rehabil 2005;32(1):72–7.
24. Balhoff DA, Shuldberg M, Hagan JL, Ballard RW, Armbruster PC. Force decay of elasto-
meric chains: a mechanical design and product comparison study. J Orthod 2011;38(1):40–
7.
25. Eliades T, Eliades G, Watts DC. Structural conformation of in vitro and in vivo aged
orthodontic elastomeric modules. Eur J Orthod 1999;21(6):649–58.
26. Rembowski Casaccia G, Gomes JC, Alviano DS, de Oliveira Ruellas AC, Sant’ Anna EF.
Microbiological evaluation of elastomeric chains. Angle Orthod 2007;77(5):890–3.
27. Teixeira L, Pereira Bdo R, Bortoly TG, Brancher JA, Tanaka OM, Guariza-Filho O. The
environmental influence of light coke, phosphoric acid, and citric acid on elastomeric
chains. J Contemp Dent Pract 2008;9(7):17-24.

70 International Orthodontics 2013 ; 11 : 60-70

View publication stats

You might also like