Performance curve
Dimensions (mm) and Weight
600 Curve Speed % W-max m3/h max
550
A (min) 23 10 94
500
B 32 24 170
 155
450
E C 46 68 289
 148
D 60 150 403

62
Static pressure - Pa

350 144 490 144


F G
E 75 286 472
300
D Model aircycyle 5.1 L

5.1
F 90 311 513

123
250
G (max) 100 333 550 B C Weight kg 44
200 C
A Intake air from outiside

180
IX

861
799
150
VIII A D B Exhaust air to outside
100 B Working point W m3/h SPI (W/m3/h) ηt %*
C Supply air to inside

247
I V VII
50
II III VI I 8,6 54 0.1585 93 D Extract air from inside
A I IV
0 II 10,7 76 0.1413 93 E Winter condensation drainage
0 50 100 150 200 250 300 350 400 450 500 550 600 279 220 279
III 13,9 97 0.1431 93 F Summer condensation drainage
19,3 92
E 778 F
Air-flow - m3/h IV 119 0.1621 549
V 25,5 140 0.1818 91
VI 32,2 162 0.1990 91
VII 46,1 191 0.2414 90
VIII 63,4 220 0.2885 89
IX 84,5 248 0.3402 89
Product fiche - ErP Directive, Regulations 1253/2014 - 1254/2014
* Unit thermal efficiency
Mark BROOKVENT
Model Aircycle 5.1
CENTRALISED
HEAT RECOVERY UNIT
SEC class A

SEC warm climates kWh/m2. a Cold -77,4 Average -39,4 Warm -15,0
Sound level Lw dB - SOUND POWER OCTAVE BAND Lp dB(A) Unit typology - Residential - bidirectional
Type of drive - Variable speed drive
Speed 100% 63 125 250 500 1K 2K 4K 8K Tot @3m
Type of Heat Recovery System - Heat recovery
Intake 83 65 70 73 62 58 53 47 84 51
Thermal efficiency of heat recovery % 82%
Supply 81 65 65 66 57 51 42 33 81 45
Extract 80 63 66 68 60 54 45 34 78 47 Maximum flow rate @ 100 Pa m3/h 520
Exhaust 78 65 70 71 62 59 53 45 80 50
Electric power input (alla Maximum flow rate) W 333
Breakout 81 69 67 69 62 56 48 36 82 48
Sound power level (LWA) dBA 58
Lw dB - SOUND POWER OCTAVE BAND 364
JReference flow rate m3/h
Speed 80% 63 125 250 500 1K 2K 4K 8K Tot @3m
Reference pressure difference Pa 50
Intake 73 61 67 69 59 56 50 43 75 47
Specific power input(SPI) W/m3/h 0,412
Supply 72 61 63 65 56 50 41 31 74 48
Control factor - 0,65
Extract 73 60 63 65 57 51 42 31 74 44
Control typology - Local demand control
Exhaust 73 61 66 67 58 55 49 41 75 46
Maximum internal leakage rate % 0,8%
Breakout 71 64 62 67 59 53 45 33 74 45 % 0,5%
Maximum external leakage rate
Lw dB - SOUND POWER OCTAVE BAND Internal mixing rate % ND
Speed 60% 63 125 250 500 1K 2K 4K 8K Tot @3m
External mixing rate % N/D
Intake 65 61 68 67 58 56 49 41 72 46 -
Visual filter warning Visual filter warning on display
Supply 63 59 63 64 55 49 40 29 69 42
Instructions to install regulated grilles - N/D
Extract 64 59 63 63 56 51 41 30 69 42 - www.brookvent.pl
Internet address for preassembly/disassembly instructions
Exhaust 64 60 66 67 57 54 48 41 71 45 %
Airflow sensitivity to pressure variations N/D
Breakout 59 64 63 65 57 51 43 31 70 44
Indoor/outdoor air tightness m3/h N/D
Lw dB - SOUND POWER OCTAVE BAND
Speed 40% 63 125 250 500 1K 2K 4K 48K Tot @3m AEC - Annual electricity consumption Cold 8,0 Average 2,6 Warm 2,2
kWh
Intake 55 55 67 55 49 47 40 31 68 39
Supply kWh Cold 88,7 Average 45,3 Warm 20,5
53 53 62 52 47 41 32 22 63 35
Extract 58 52 60 51 47 42 32 22 63 34 Ambient temperature max C 40
Exhaust 55 54 66 55 49 47 40 31 67 39 Degree of protection IP - X4

Breakout 54 53 59 52 48 43 33 23 62 34

Lp dB(A) @3m for comparative purposes only (preliminary data)

Kontakt:
Suitable for
large houses
Biuro Handlowe:
Polska Sp. z o.o.
tel: +48 71 310 52 82 e-mail: informacja@brookvent.pl
Kościuszki 14-16 | Oborniki Śląskie 55-120 fax: +48 71 750 36 22 www.brookvent.pl
Aircycle 5.1 Whole-house heat recovery unit, suitable for vertical installation. Example of a complete
Cechy & zalety
Specification
ventilation system.
5.1
Outer fan casing manufactured from powder coated galvanised sheet steel providing long lasting and robust
construction. The unit is finished in white RAL 9010.

EC external rotor motors fitted as standard for energy saving. Provided with integral thermal protection,
mounted on sealed for life ball bearings.

Backward curved centrifugal impeller dynamically balanced and directly driven by the motor to
provide a smooth airflow through the unit.

Highly efficient counterflow heat exchanger to maximise thermal recovery.

Semi-rigid circular
ducting
BOREA
Air extract

features & benefits


Distribution
plenum
BOREA
Air inlet

of ventilation system Insulated


ducting

Ease of installation: fixing bracket supplied Tested to the latest standards: units are
to hang the unit easily on the wall. tested in the TÜV Rheinland recognised aircycle 5.1 L
laboratory at Aerauliqa, meaning accurate, The unit is supplied with a multi-functionLCD display (CTRL-DSP) for automatic control and
Removable front panel for quick access up to date information on electrical safety, convenience, providing:
to filters and heat exchanger. performance and noise level that can be relied
upon. 5.1

G4 filters easy removable for cleaning.


The unit is also provided with the F7 filter Unit Therma efficiency air leakage Application: recommended in case of new build.
accessory at the intake side. and energy efficiency measured at • 3 speeds setting (adjustable). • Setting saving and loading
indipendent laboratory BRE (UK). • Boost option. • Volt-free contacts for remote ambient sensors How it works: a continuous running heat recovery unit (QR550) transfers heat from humid air
Integral physical bypass for free cooling • Holiday mode. (SEN-HY, SEN-PIR, SEN-CO2). extracted from wet rooms to warm incoming fresh air which is ducted to habitable rooms. Thanks
during the summer season: automatic Designed and manufactured in accordance • Night mode: during night time the automatic • Analogic input 1-10V for “slave” function if connected to the easy-to-fit air distribution system each single ambient can be properly ventilate: the boost
operation in the ABP version, manual with EN60335-2-80 (Low Voltage Directive) operation via sensors is deactivated to prevent to BMS (home automation) system. function enables rapid extract of increased moisture or pollutant levels. It also provides discrete
in the MBP version. and the EMC Directive (Electromagnetic installation and very quite operation.
undesired speed rise and consequent noise • Integral S/L terminal for boost from remote switch,
Compatibility). increase. i.e. light or dedicated switch.
Automatic anti-frost protection to prevent Energy saving: the preheated/precooled fresh air and continuous air changes reduce the demand
frost building up on the intake side of the heat • Automatic Bypass. • Connection to remote pre/post heating element.
for additional heating/air-conditioning. The EC brushless motors significantly reduce the electricity
exchanger. • Airflow balancing. • Connection to remote dehumidifying element. consumption.
• Filter replacement and fan failure indicator. • Possible change of orientation of the atmosphere
Two drainage holes to meet climate • Woking hour counter. spigots. Indoor Air Quality: a correctly specified mechanical ventilation system can ensure the quality of the
requirement. indoor air is constantly maintained for the health and well-being of the occupants as well as of the
building. Duly maintained filters ensure that incoming air is suitably filtered of dust and pollen before if
enters the home.