You are on page 1of 6

Palm Oil to be Pumped in the System

Q Flow Rate 100 m3/hr 0.028 m3/sec


Sp Density 920 kg/m3 920 kg/m3
μ Viscosity 22 cp 0.022 Ns/m2
v Velocity 1.5 m/sec 1.5 m/sec
L Pipe Length 100 m 100 m
Pipe Dia 100 mm
r Pipe Radius 50 mm 0.05 m

P2-P1 Pressure Diff N/m2

P2-P1 (8*μ*L*Q)/(Pi*r^4)

P P2-P1 24898.90665 N/m2 Approx 0.25 Bar

Second Equation

H P/γ+ V^2/2g+h

Pressure Head P/γ 2.758820486 m

Velcoity Head V^2/2g 0.114678899 m

Elevation Head 15 15 m

Total HeadLoss
Pipe OD 114.3 mm
Pipe thk 6.02 mm

Pipe ID 102.26 mm
Area 0.008212993 m2
<v> 3.382174736 m/s

Re=rhoVD/mu 14463.28606
flow is highly turbulent

Pipe OD 168.3 mm
Pipe thk 7.11 mm

Pipe ID 154.08 mm
Area 0.01864586 m2
<v> 1.489755777 m/s

Re=rhoVD/mu 9599.011116
flow is highly turbulent, and nowhere near the critical region

To find fd Karman Prandtl resistance equation https://en.wikipedia.org/w


let fd = 0.030880942
0.000692182 this is obtained by goal seek

DeltaP/L 204.6125487 Pascal/metre

For 100m pipe 100 m


Delta P 20461.25487 Pascal

Pressure required at source is calculated as per Example 1 of attached document


154818.34362 Pascal http://www.freestudy.co.uk/fluid%20mechanics/t220
154.81834362 kPa

The duty point of the Pump should intersect the H-Q curve at this pressure and flow
Please check that the thickness of the Pipe can sustain the pressure as per ANSI B31
e critical region

ps://en.wikipedia.org/wiki/Darcy%E2%80%93Weisbach_equation

y goal seek

attached document
uid%20mechanics/t2203.pdf

this pressure and flow, which should also match with Best Efficiency Point at selected speed
essure as per ANSI B31.3
Palm Oil to be Pumped in the System

Q Flow Rate 40 m3/hr 0.011 m3/sec


Sp Density 920 kg/m3 920 kg/m3
μ Viscosity 22 cp 0.022 Ns/m2
v Velocity 1.5 m/sec 1.5 m/sec
L Pipe Length 100 m 100 m
Pipe Dia 100 mm
r Pipe Radius 50 mm 0.05 m

P2-P1 Pressure Diff N/m2

P2-P1 (8*μ*L*Q)/(Pi*r^4)

P P2-P1 9959.562661 N/m2 Approx 0.25 Bar

Second Equation

H P/γ+ V^2/2g+h

Pressure Head P/γ 1.103528195 m

Velcoity Head V^2/2g 0.114678899 m

Elevation Head 15 15 m

Total HeadLoss
Pipe OD 114.3 mm
Pipe thk 6.02 mm

Pipe ID 102.26 mm
Area 0.008212993 m2
<v> 1.352869894 m/s

Re=rhoVD/mu 5785.314425
flow is highly turbulent

Pipe OD 114.3 mm
Pipe thk 6.02 mm

Pipe ID 102.26 mm
Area 0.008212993 m2
<v> 1.352869894 m/s

Re=rhoVD/mu 5785.314425
flow is turbulent, and just above the critical region

To find fd Karman Prandtl resistance equation https://en.wikipedia.org/w


let fd = 0.035293284
-0.00015542 this is obtained by goal seek

DeltaP/L 290.5736185 Pascal/metre

For 100m pipe 100 m


Delta P 29057.36185 Pascal

Pressure required at source is calculated as per Example 1 of attached document


163593.44365 Pascal http://www.freestudy.co.uk/fluid%20mechanics/t220
163.59344365 kPa

The duty point of the Pump should intersect the H-Q curve at this pressure and flow
Please check that the thickness of the Pipe can sustain the pressure as per ANSI B31
ps://en.wikipedia.org/wiki/Darcy%E2%80%93Weisbach_equation

y goal seek

attached document
uid%20mechanics/t2203.pdf

this pressure and flow, which should also match with Best Efficiency Point at selected speed
essure as per ANSI B31.3

You might also like