You are on page 1of 2

2400

Min Recirculation Flow : 105 m3/hr


2300
NOTE:
2200
1 -SUCTION FLOW=HP FLOW + IP FLOW.
2100
2 -IP FLOW SPECIFIED AT THE PARTICULAR CONDITION IS ASSUMED TO BE
A
HEAD (mwc)

2000 CONSTANT FOR ALL THE LOWER FLOWS AT THE PARTICULAR OPERATING
CONDITION.
1900
3 -NPSHR,POWER & EFFICIENCY CURVES ARE INDICATED FOR THE SEVERE
1800 OPERATING CONDITION ONLY i.e. FOR THE RATED PARAMETERS.
B
1700 C

1600

1500

1400
3000
A RATED 420 2012 4970 78.5 2690.0 149.5 0.917 17.5
POWER (kw)

2500 A
2000 B MAX HP 440 1688 4660 79.0 2350.0 149.5 0.917 18.0

1500
C MAX IP 420 1717 4650 78.5 2296.0 149.5 0.917 17.5
1000
Flow HEAD Speed EFFY. POWER TEMP SP. GR. NPSHR
90
REF (m3/ hr.)
(HP+IP)
ςςςς
(mlc) (rpm) (%) ( kw) ( C) (gr/cc) (mlc)

80 A

70
EFFICIENCY (%)

60

50 25
3% ΔH

40 20
PROJECT : GSPC, 2 x 350 MW GAS BASED CCPP PIPAVAV
A
NAME SIGN. DATE
30 15 PUMPS ENGINEERING
NPSHR (mlc)

PRPD P.R.CHARY 12.11.08


20 10 BHARAT HEAVY ELECTRICALS LTD. CHKD. B.PRAKASH 12.11.08
HYDERABAD.
10 5 APPD BRK 12.11.08

PUMP TYPE : FK6D30 TEST CODE


0 0 HIS
TITLE
DRG. NO. : Rev. :
0 100 200 300 400 500 ESTIMATED PERFORMANCE HY-DG-3-18000-65466 00
SUCTION FLOW(cub. m. / hr.)
CURVE OF BFP(HP+IP) SHEET NO. : 2 NO. OF SHEETS : 2

You might also like