SHIP SECURITY ALERT SYSTEM (SSAS)

(For FELCOM12/15/16)
The paper used in this manual
is elemental chlorine free.

FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
Nishinomiya 662-8580, JAPAN

Telephone : 0798-65-2111
Fax : 0798-65-4200

All rights reserved. Printed in Japan FIRST EDITION : MAY. 2004


D : SEP. 09, 2005
Pub. No. OME-56351
*00015035913*
( DAMI ) IC-307(SSAS) *00015035913*
*00015035913*

*OME56351D00*
*OME56351D00*
*OME56351D00*
TABLE OF CONTENTS

SYSTEM CONFIGURATION .........................................................................................2

1. OVERVIEW OF SSAS ..............................................................................................4

2. INSTALLATION.........................................................................................................6
2.1 Mounting ......................................................................................................................... 6
2.1.1 Junction box (for FELCOM 16) ............................................................................... 6
2.1.2 I/F box IC-312 (for FELCOM 12)............................................................................. 7
2.1.3 SSAS alert unit ....................................................................................................... 8
2.2 Wiring............................................................................................................................ 10
2.2.1 Junction box (for FELCOM 16) ............................................................................. 10
2.2.2 I/F box IC-312 (for FELCOM 12)........................................................................... 11
2.2.3 SSAS alert unit ..................................................................................................... 12
2.3 Initial Settings................................................................................................................ 13

3. OPERATION............................................................................................................14
3.1 Operation Mode ............................................................................................................ 14
3.1.1 Changing the password ........................................................................................ 14
3.1.2 SSAS manager mode ........................................................................................... 15
3.2 Setting SSAS Report Destination and Message Contents............................................. 16
3.3 Transmitting SSAS Report ............................................................................................ 19
3.4 Testing the Button ......................................................................................................... 21
3.5 SSAS Report Test ......................................................................................................... 27

OUTLINE DRAWINGS...............................................................................................D-1
INTERCONNECTION DIAGRAMS ...........................................................................S-1

1
SYSTEM CONFIGURATION
Regulations require at least two SSAS alert units.

FELCOM 15

ANTENNA
UNIT
IC-115

DGPS

EGC Printer 24 VDC


100-115/200-230 VAC PP-50
TERMINAL UNIT
1φ, 50/60 Hz IC-215
AC-DC Power Supply Personal
Computer Printer
24 VDC PR-240-CE*1
(PC/AT compatible)
GPS receiver
12-24 VDC OP16-24 Shipboard LAN (Ethernet)

Printer
24 VDC
PP-510

Mini Keyboard Distress Alert/


Received Call Unit
IC-305
SSAS Alert Unit SSAS Alert Unit
IC-307 IC-307 JUNCTION
(Max. 3 units) BOX Alarm Unit
IC-315 IC-306
SSAS Alert Unit
IC-307
Navigator
: Standard Supply
*1 Any AC-DC power supply
: Option
fulfilling requirements of
: Local Supply IEC 60945 may be used.

FELCOM 16

ANTENNA
UNIT
IC-116

100-115/200-230 VAC AC-DC PRINTER


1φ, 50/60 Hz Power Supply
PR-240-CE COMMUNICATION UNIT IC-216
24 VDC (with internal GPS receiver)
FURUNO INMARSAT MINI-C MOBILE EARTH STATION
PERSONAL
ER

R
IN

RO
W

COMPUTER
PO

LO

ER
TX

12-24 VDC O POWER I

(PC/AT compatible)

SSAS Alert Unit SSAS Alert Unit SSAS Alert Unit JUNCTION BOX : Standard
IC-307 IC-307 IC-307 IC-315 : Option
: Local Supply
(Max. 3 units)

2
FELCOM 12
Antenna Unit
IC-112

Navigator

100/110/200/220V
1φ, 50/60 Hz Communication Distress Alert Unit
AC-DC Unit IC-302
Power Supply IC-212
PR-300 INMARSAT-C MOBILE EARTH STATION
24 VDC POWER
Received Call Unit
ON OFF
IC-303

Terminal Unit Distress Alert Unit


IB-581/IB-582 IC-302
OR
24 VDC
Distress Message Controller
24 VDC
DMC-5
24 VDC Priinter POWER BRIGHT CONTRAST

PP-510
SSAS Alert Unit
Mini Keyboard Interface 24 VDC
IC-312
PC
(PC/AT compatible) SSAS Alert Unit
IC-307
OR
Terminal Unit SSAS Alert Unit
IB-581/IB-582 (Max. 3 units)
IC-307
: Standard
: Option
SSAS Alert Unit
: User Supply IC-307

3
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15/FELCOM 12 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting
specified addresses (for example, your ship’s company) that your ship is under attack by
intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed
before 01 July 2004 to install an SSAS.

When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.

The SSAS is protected with a password to prevent unauthorized setting or testing of it by


other than the ship’s captain or authorized personnel.
Inmarsat System

Ship Name, MMSI No.,


Ship Position, etc.

Headquarters

Ship

Ship's Company,
Management Company

4
SSAS operation flow

1. Open the cover of the button and then press the button.
(This is a latch-type button; hit and release to activate the button.)

2. If addresses have been preset, the SSAS report is sent to one


address 30 seconds after the button is activated.
(Max. 5 addresses)

(You may cancel transmission of the SSAS report by pressing the


button again within 30 seconds of the initial press.)

3. An LES sends acknowledgement to your ship.
4. Steps 2-3 and are repeated in case of multiple addressees.

5. Continuous transmission of the SSAS report begins.
(The interval at which to transmit the SSAS report to each address
can be specified. The SSAS report is continuously transmitted
while the button is ON, at the interval selected.)

6. To stop transmission, press the button again to deactivate it.
(This is only possible in the SSAS manager mode. See
paragraph 3.1.)

5
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16; it is
already installed on the FELCOM 15.

Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.

Standard compass: 1.0 m


Steering compass: 0.7 m

1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.

120 ±0.5

70 ±0.5

Junction box IC-315


The junction box is connected to the communication unit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.

6
2.1.2 I/F box IC-312 (for FELCOM 12)
The I/F box is required to connect the SSAS alert unit to the FELCOM 12.

The I/F box is connected to the communication unit with a 5 m cable (17JE-573-10 harness).
Accordingly, locate the interface within 5 m of the communication unit.

Keep the following compass safe distances in mind when choosing the mounting location:
Standard compass: 0.65 m
Steering compass: 0.45 m

1. Unfasten four screws to remove the cover.


2. Use four self-tapping screws (3X10, supplied) to fix the unit to the mounting location.
3. If the cable is led in from the rear of the unit, change the clamp location as follows:
a) Unfasten two screws to remove the clamp.
b) Turn the clamp 90 degrees.
c) Fasten the clamp.
Unfasten two screws.
Fasten clamp with two screws.

Clamp

Turn

4. Pass the cable through the clamp and connect it to the terminal board, referring to the
interconnection diagram.

7
2.1.3 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.

Standard compass: 0.70 m


Steering compass: 0.45 m

Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.

Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.

Unfasten three screws.

Clamp

Rotate

Fasten three screws.

4. Run the cable thru one of the cable entrances and connect it to terminal board.

8
5. Attach the switch cover as shown below. Note that the cover may be turned 180° to
change cover opening direction.
Press here and hold down for five seconds.

Switch cover

Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-7201-1 100-317-931 1
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-802-080 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws
(supplied).
4. Attach switch cover as shown above.

9
2.2 Wiring
2.2.1 Junction box (for FELCOM 16)
Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten
four screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.

For connection, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view
of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P
cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the
junction box.

1 Vcc

IC-305/306
2 GND
3 TD/RD-A
4 TD/RD-B
Cover 5 NC
6 TD-A(NAV) 1
7 TD-B(NAV) 2
8 RD-A(NAV)
9 RD-B(NAV)
10 GND
11 DMC OUT-H
Cable clamp 12 DMC OUT-C
(top) 13 DMC IN-H
14 DMC IN-C 3 Core 7 mm
15 DMC CTR
Terminal
board
Communication
Unit
Cable clamp Cable clamp Procedure
(bottom)
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
Note 1: Do not insert the cable too
deeply, to prevent pinching the sheath.
Fold back braided shield onto
sheath and fix by cable clamp. Note 2: Pull each cable slightly to con-
16S0344
firm that they are in their holes securely.

15mm 90mm 7mm

Junction box IC-315

10
2.2.2 I/F box IC-312 (for FELCOM 12)
FELCOM 12 is connected to the SSAS Alert Unit via the I/F Box IC-312.

For detailed wiring refer to the interconnection diagram at the back of this manual.
Communication Unit
(rear view)

BUZZER DMC1 DMC2 ANT BREAKER 24VDC

NMEA

DTE 1 DTE 2 DATA

OR

24 VDC

MJ-A3SPF0016-035 (3.5 m) 17JE-573-10 Harness (5 m)

Twist shield.

CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
16P0231
Cut and tape
unused wires 15 mm 40 mm
to prevent short.
Clamp for cable 1 2 3 4 5 6
CO-SPEVV-SB-C 0.2X5P

Armor

Sheath
Clamp for cable
TTYCS-4 (or equivalent) Shield
Conductor
S = 0.75 mm 2
φ = 1.11 mm
Sectional view of cable TTYCS-4
Cable from
SSAS Alert Unit

Wiring I/F box IC-312

11
2.2.3 SSAS alert unit
Three SSAS alert units can be connected. For wiring, see the illustrations below and the
interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15) and
the communication unit (FELCOM 16/FELCOM 12), the wiring of the SSAS is monitored
and if in error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the
ERROR lamp (FELCOM 16) flashes.

Junction
Box
IC-307 IC-307 IC-307
(No.1) (No. 2) (No. 3)

Connect wiring to the terminal board 16P0229 inside the SSAS unit. To differentiate
between units in case of multiple unit installation, change jumper block settings as shown
below, in accordance with how many units are installed.
Jumper settings for two IC-307 Jumper settings for three IC-307
Unit No.1 unit* No. 2 unit Unit No.1 unit* No. 2 unit* No. 3 unit
Jumper *: Default Jumper
JP1 No Yes setting JP1 No No Yes
JP2 Yes No JP2 Yes Yes No
No. 1 unit: Unit with two cables connnected to it. No. 1 and No. 2 units: Units with two cables connnected to them.
No. 2 unit: Unit with one cable connnected to it. No. 3 unit: Unit with one cable connnected to it.

Two IC-307: No. 2 Two IC-307: No. 1


Three IC-307: No. 3 Three IC-307: No. 1 and No. 2

16P0229 16P0229
JP1 JP2 JP1 JP2

1 2 3 4 5 6 1 2 3 4 5 6

IC-307 IC-307
Cable Fabrication

Twist shield.
Clamp for cable
CO-SPEVV-SB-C CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
0.2x5P
Cut and tape
unused wires 15 mm 40 mm 10 mm
to prevent short.
f = 16.3 mm
Clamp for cable Armor
TTYCS-4
or equivalent Sheath
Shield
Conductor
S = 0.75 mm2
φ = 1.11 mm
Sectional view of cable TTYCS-4

Wiring inside the SSAS alert unit

12
2.3 Initial Settings
Set up the SSAS as follows:

1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU *** RFCONCPU ***
[ Main Menu ] [ Main Menu ]
1. Remote Box Setup 1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
Enter JOB No. :

FELCOM 15/FELCOM 16 FELCOM 12

3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press
the [Enter] key. The prompt PASSWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then,
the item Main Menu is displayed in reverse video.
5. Press [1], [Enter], [1], [Enter]. One of the following windows appears.
[ DMC ] [ SSAS ]
1. SSAS(IC-307) 1. ON(IC-307)
2. DMC 2. OFF
3. OFF 3: Momentary SW (for USCG)
4: SSAS(Momentary SW) E: Exit E: Exit
Enter No.: Enter No.:

FELCOM 15 FELCOM 16

[ SSAS I/F (IC-312) ]


1. DTE2 Port
2. DATA Port
3. OFF E: Exit
Enter No.:

FELCOM 12

6. FELCOM 15/FELCOM 16: Press [1], [Enter]. This enables the SSAS functions.
FELCOM 12: Choose the port where the SSAS unit is connected and then press the
[Enter] key.
7. Press the [Esc] key several times to close the menu.

Note: Test the SSAS button and SSAS report for proper operation, referring to paragraphs
3.4 and 3.5, respectively.

13
3. OPERATION
3.1 Operation Mode
There are two menu operating modes:

Normal mode: Menus other than SSAS-related menus are displayed.


SSAS manager mode: The mode is activated by the password entered by the ship’s
captain or authorized personnel. The indication “SSAS Manager
Mode” is shown at the top of the screen when this mode is
activated, and it is flashing on the FELCOM 15/FELCOM 16. All
SSAS-related menus are available. Transmission of the SSAS
report may be cancelled in this mode. The equipment starts up in
the normal mode, regardless of the mode in use when the power is
turned off.

3.1.1 Changing the password


The default password is “ship security alert”. Ship’s captain or authorized personnel may
change the password as follows:

1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU *** RFCONCPU ***
[ Main Menu ] [ Main Menu ]
1. Remote Box Setup 1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
Enter JOB No. :

FELCOM 15/FELCOM 16 FELCOM 12

3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then
press the [Enter] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW
PASSWORD appears.
5. Enter new password, using at least six characters, and then press the [Enter] key. The
prompt RETYPE NEW PASSWORD appears.
Note: If less than six characters are entered for the password, the message “Please
use a longer password.” appears. Enter a longer password.
6. Enter new password again and then press the [Enter] key. The message “Password
changed” appears.
7. Press the [Esc] key several times to close the menu.

Note: The SSAS manager mode cannot be unlocked without the proper password.

14
3.1.2 SSAS manager mode
All SSAS-related settings are set in the SSAS manager mode. Do the following to access
this mode.

1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU *** RFCONCPU ***
[ Main Menu ] [ Main Menu ]
1. Remote Box Setup 1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
Enter JOB No. :

FELCOM 15/FELCOM 16 FELCOM 12

3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode
is activated, and it is flashing on the FELCOM 15/FELCOM 16.
CAUTION
04-04-20 05:37 (UTC)
SSAS Manager Mode enabled.

<Press ESC key to continue>

5. Press the [Esc] key several times to close the menu. This enables the SSAS manager
mode, which allows you to execute the procedure in paragraph 3.2.

Note: Turn the power off and on again whenever changing SSAS-related settings.

15
3.2 Setting SSAS Report Destination and
Message Contents
When the SSAS is activated, the SSAS report is sent according to the addresses (max. 5)
and message content set with SSAS Report 1 – SSAS Report 5 on the SSAS Report menu.
Note 1: The destination and message content of an SSAS report varies according to
Administration. Therefore, set them as requested by ship’s authorities. For
information other than ship’s name, MMSI no. and IMN no., set it manually with
“Other Inf.”
Note 2: The equipment must be in the SSAS manager mode to execute this procedure.
See paragraph 3.1.2.
1. Press the [F5] to open the Reports menu.
Reports
1. Data Report
2. Message Report
3. Data Network ID
4. SSAS Report

2. Press the [4] key to shown the SSAS Report menu.


SSAS Report
1. SSAS Report 1
2. SSAS Report 2
3. SSAS Report 3
4. SSAS Report 4
5. SSAS Report 5
6. Message Contents

3. Press [1], [2], [3], [4] or [5] key as appropriate.


Note: When the button is tested on the FELCOM 12, the test report is sent to the
station having the youngest SSAS report number. Therefore set at SSAS Report
1 the station which is to receive the test report.
SSAS Report
Status ON
Mode Real+Test
Station Name
Destination Type TELEX
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Address
Subject
LES ID
Report Interval 02:00 (hh: mm)

SSAS report window (FELCOM 15/FELCOM 16)

16
4. FELCOM 15/16: Press the [↓] key to choose Mode and then press the [Enter] key.
FELCOM 12: Go to step 6.

Real+Test
Real Only
Test Only

5. Press the [↑] or [↓] key to choose mode desired and then press the [Enter] key.
“Mode” defines what SSAS report(s) a station is to receive:
Real+Test: Actual SSAS report and test SSAS report.
Real Only: Actual SSAS report only.
Test Only: Test SSAS report only.
6. Press the [↓] key to choose Station Name and then press the [Enter] key.
7. Press the [↑] or [↓] key to choose appropriate station and then press the [Enter] key.
You may sort the list by group name, station name or communication type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or
descending order.
Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or
descending order.
Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in
ascending or descending order.
8. Press the [↓] key to choose LES ID and then press the [Enter] key.
9. Press the [↑] or [↓] key to choose LES and then press the [Enter] key.
Note: Change the LES whenever sea area has changed. However, the equipment
automatically searches for an LES with which you can communicate and the
SSAS report is transmitted to that LES.
10. Press the [↓] key to choose Report Interval and then press the [Enter] key.
11. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]
key.
12. Press the [Esc] key to open the Update window .

SSAS Report
Status ON
Mode Real+Test
Station Name
Destination Type TELEX
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Update
Address
Subject
Yes No
LES ID
Report Interval 02:00 (hh: mm)

FELCOM 15/ FELCOM 16 SSAS report window w/update window


13. Yes is selected; press the [Enter] key to close the SSAS report window.

17
14. Press the [6] key to display the SSAS Message Contents menu.
SSAS Message Contents
Vessel Name : ______________________________
MMSI : _________
IMN : _________
Other Inf. : _______________________________________________________
_______________________________________________________
_______________________________________________________
LAT: 34: 44. 46N
LON: 135: 21. 26E
Time: 02/04/2004 04:31:48 (UTC)
COURSE: 071 deg
SPEED: 00 kt
Time: 02/04/2004 04:31:48 (UTC)

15. Press the [Enter] key to open the Vessel Name window.
16 Enter vessel’s name and then press the [Enter] key.
17. Press the [↓] key to choose MMSI and then press the [Enter] key.
18. Enter MMSI number and then press the [Enter] key.
19. Press the [↓] key to choose IMN and then press the [Enter] key.
20. Enter IMN and then press the [Enter] key.
21. Press the [↓] key to choose Other Inf. and then press the [Enter] key
22. Enter appropriate message (three lines) and then press the [Enter] key.
Note: To shift between lines, use the [↑] or [↓] key.
23. Press the [Esc] key to open the Update window.
24. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
25.Press the [Esc] key twice to return to the standby display.

Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.”


Note 2: SSAS report settings may be saved to a floppy disk for backup.
FELCOM 15: [F8], [9], [6] to show the Save/Load window.
FELCOM 16: [F8], [8], [6] to show the Save/Load window.
Save to FD Load from FD
1. ALL 1. ALL
2. Station List 2. Station List *: Availlable only in SSAS manager mode
3. LES List 3. LES List ("5.SSAS Report" is added in the SSAS
4. E-Mail Service List 4. E-Mail Service List
5. SSAS Report*
manager mode and item numbers are shifted.)
5. SSAS Report*
6. Other 6. Other

Note 3: To confirm the settings, follow paragraph 3.5.

18
3.3 Transmitting SSAS Report
In the normal mode, the SSAS report is sent 30 seconds after the button on the SSAS is
pressed. The SSAS repeatedly transmits the report even if the button is pushed off ( ).
Repeated transmission can only be stopped from the SSAS manager mode.

1. Open the cover of the SSAS alert button.

Cover

2. Push the button. The button is a latch-type button; hit and release the button to activate
( ) the SSAS unit.
3. The SSAS report is transmitted 30 seconds after the button is pushed in ( ). Below are
the contents of the SSAS report.
- - - SSAS ALERT MESSAGE - - -
Vessel Name: Queen Elizabeth 2 Ship's Name
MMSI: 111660000 MMSI No.
IMN: 443100000 IMN No.
Help me! Desired message
LAT: 34:44.46N Own ship postion in latitude
LON: 135:21.26E Own ship position in longitude
Time: 02/04/2004 04:31:48 (UTC) Time of position data
COURSE: 071 deg Course
SPEED: 00 kt Speed
Time: 02/04/2004 04:31:48 (UTC) Time of course and speed data

Note: If you accidentally push the button in, push it again within 30 seconds to cancel
the report. The button pops out ( ) and the report is not transmitted. When this
is done, the message “INF: SSAS UNIT activation has been canceled.” appears
on the display. Additionally, for the FELCOM 16, the POWER lamp on the
communication unit flashes 30 seconds.
4. An LES sends acknowledgement to your ship.
5. For multiple destinations, steps 3 and 4 are repeated.
6. The SSAS report is transmitted repeatedly while the button remains pushed in ( ).
7. To stop transmission, push the button again to pop it out ( ). (SSAS manager mode
only.)

19
Note 1: You may cancel repeated transmission from either operating mode by pushing the
button OFF→ON→OFF→ON→OFF. You must allow no more than three seconds
to elapse before pushing the button again. If more than three seconds elapses,
repeat the procedure. When transmission is stopped, the message “INF: SSAS
UNIT activation has been cancelled.” appears and, on the FELCOM 16 only, the
POWER lamp on the communication unit flashes approx. 30 seconds.
Note 2: If transmission is not canceled with the button and the power is turned off, the
equipment resumes repeated transmission when powered again.

20
3.4 Testing the Button
The SSAS button can be tested as below.

Note 1: An actual SSAS report cannot be transmitted during the testing.


Note 2: The equipment must be in the SSAS manager mode to conduct the test.

FELCOM 15
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test

3. Press the [4] key.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select NCS
Self Test Start
5.4.Ocean Region
Distress Alarm Button Test
6. Test Yes No

4. Press the [Enter] key to start the test.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select
Self NCS
Distress/SSAS
Test buttons are under test mode.
5.4.Ocean Region
Distress Press
Alarm any key
Button CAUTION
Testto escape.
INF: Distress/SSAS
6. Test Buttons entered into TEST MODE.

<Press ESC key to continue>

The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent.” appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the
station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”.
8. Turn the button of the No. 1 SSAS off ( ).
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.

21
9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

Further, because the button remains pushed in ( ), the message “Please return the
SSAS button into OFF-STATE.” appears.
10. Push the button again to pop it out ( ).
11. Close the button cover.
12. Press the [Esc] key three times to return to the standby display.

Note: If the button is left pushed in ( ) when the terminal unit is turned on, the equipment
displays “Please return the SSAS button into OFF-STATE.” Push the button again to
turn off ( ) the button.

22
FELCOM 16 (no PC)

Turn off communication unit.

Turn on button of No. 1 SSAS.

Turn on communication unit.

30 s

POWER, LOGIN and TX lamps flash


in that order.

Send SSAS No (within 30 s)


test report?

Yes (after 30 s)

SSAS report is sent to station(s)


whose mode is "Real+Test" or "Test
Only". (See paragraph 3.2.)
Lamps flash rapidly during TX. Test TX

Test No ERROR lamp flashes rapidly.


successful?

Yes

POWER, LOGIN and TX lamps flash in


that order. ERROR lamp also flashes.

Turn off button of No. 1 SSAS.

The POWER, LOGIN and TX lamps flash


in that order.

Turn on button of No.2 SSAS.

Test TX

Turn off button of No.2 SSAS.

Note: If a 3rd SSAS unit is installed


test it by procedure used to test
Turn communication unit off and No.2 unit.
on again.

23
FELCOM 16 (by PC)
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test

3. Press the [4] key.


Options
1. Login Test
2.1.Logout
PV Test SSAS Button Test
3.2.Abort
PV Test Result
4.3.Select NCS
Self Test Start
5.4.Ocean Region
Distress Alarm Button Test
6. Test Yes No

4. Press the [Enter] key to start the test.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select
Self NCS
Distress/SSAS
Test buttons are under test mode.
5.4.Ocean Region
Distress Press
Alarm any key
Button CAUTION
Testto escape.
INF: Distress/SSAS
6. Test Buttons entered into TEST MODE.

<Press ESC key to continue>

Test mode

The display shows the message (in red) “SSAS buttons are under test. Cancel the test
mode if a real SSAS alert needs to sent.” appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button in (ON). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the
station(s) whose Mode set on the SSAS Report window is “Real+Test” or Real Only”.
8. Turn the button of the No. 1 SSAS off ( ).
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.

24
9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

Further, because the button remains pushed in ( ), the message “Please return the
SSAS button into OFF-STATE.” appears.
10. Push the button again to pop it out ( ).
11. Close the button cover.
12. Press the [Esc] key three times to return to the standby display.

Note: If the button is left pushed in ( ) when the communication unit is turned on, the
equipment will go into the test mode if the SSAS is not transmitting repeatedly. To
return to the standby display, push the button again to pop it out ( ) and then turn
the communication unit off and on again.

FELCOM 12
1. Press the [F7] key to open the Options menu.
2. Press the [6] key if the FELCOM 12 operates as an Inmarsat C MES or the [5] key if it
operates as an EGC receiver.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test

Test menu
3. Press the [4] key.
Options
1. Login Test
2.1.Logout
PV Test Distress/SSAS Button Test
3.2.Abort
PV Test Result
4.3.Select NCS
Self Test Start
5.4.Ocean Region
Distress Alarm Button Test
6. Test Yes No

Start window
4. Press the [Enter] key to start the test mode.

25
Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select NCS
Distress/SSAS alert button test mode.
Self Test
5.4.Ocean Region
Distress Press
Alarm any key
Button CAUTION
to escape.
Test
INF: DMC/SSAS
6. Test switch TEST started.

<Press ESC key to continue>

Display during testing


5. Open the cover of the No. 1 SSAS unit.
6. Press the button of the No. 1 SSAS unit to turn on ( ) the unit.
The CAUTION window displays the message “SSAS UNIT works correctly.” if the unit is
functioning properly.
7. 30 seconds after the button is pushed in, the SSAS test report is automatically sent to
the station specified in the youngest SSAS report number.
8. Turn the button of the No. 1 SSAS off ( ).
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.
9. After the test is completed, press the [Esc] key on the keyboard twice to return to the
standby mode. The following message appears.
CAUTION
INF: DMC/SSAS switch TEST terminated.

<Press ESC key to continue>

Display at completion of test


Further, with the button left in the “ON” state ( ) the message “[Please return the SSAS
button into OFF-STATE.” appears.
10. Press the button again to turn it off ( ).
10. Close the button cover.
11. Press the [Esc] key three times to return to the standby display.

Note: If you turn off the communication unit with the button of an SSAS unit turned on ( )
the message “Please return the SSAS button into OFF-STATE.” appears. Press the
button to turn it off ( ).

26
3.5 SSAS Report Test
You can test for successful transmission of the SSAS report to the address you specify,
without using the button. The test report message states “!!! Test Call !!!” to alert the
receiver of the message that it is a test call.

Note: This function is only available in the SSAS manager mode. Switch to this mode (see
paragraph 3.1.2) and then follow this procedure.

1. Press the [F5] key to open the Reports menu.


2. Press the [4] key to choose the SSAS Report menu.
3. Press the [1], [2], [3], [4] or [5] key as appropriate, and the SSAS report setting menu
appears.
4. Set destination where to transmit the test.
5. Press the [↑] key to choose Status and then press the [Enter] key.
6. Press the [↓] key to choose TEST and then press the [Enter] key.
7. Press the [Esc] key to open the Update window on the FELCOM 15/FELCOM 16 or the
Entry window on the FELCOM 12.
8. Yes is selected; press the [Enter] key. The test report is transmitted. After it is
transmitted, “Status” is automatically set to ON.
9. Press the [Esc] key twice to return to the standby display.

27
D-1

Mar.03'05
D-2

Y. Hatai
D-3

Y. Hatai
Y. Hatai
D-4
1 2 3 4 5 6 S-1

アンテナユニット
ANTENNA UNIT
IC-115
アラームユニットIC-306
GND ALARM UNIT
RW-4747 ケーブル:コネクタ、選択
16P0213B

TNCP-NJ
0.3m CABLE: CONNECTOR, SELECTED ターミナルユニット
TPA5FB0.3NJ5 1 VCC
FBA-5DFB,0.3m TERMINAL UNIT P
12D-SFA-CV,100m,φ20: N-P-12DSFA 2 GND
8D-FB-CV,50m,φ14.3: N-P-8DFB IC-215
3 TD/RD-A
A P
4 TD/RD-B
ANT DGPS *1 5 FG
TP5FBAW-5DFBB,30m,φ10.7 BNC PLAG COAX. CABLE(50Ω) DGPSデコーダー
DGPS DECODER

2B02 16P0208A 遭難警報器 IC-305


接続箱 DISTRESS ALERT/
*3 JUNCTION BOX RECEIVED CALL UNIT
キーボード D-sub15P IC-315 *1
KEYBOARD JUNCTION 16P0213A
KEYBOARD 1 付属ケーブル,2m TTYCS-4 1 VCC
KDAT Vcc(ALM) 1 1
BTC-5100C PS/2 2 ATTACHED CABLE P
NC GND 2 2 2 GND
3 GND TD/RD-A 3 3 3 TD/RD-A
P
4 +5V TD/RD-B 4 4 4 TD/RD-B
5 KCLK NC 5 5 5 FG
6 NC TD-A 6 6
TD-B 7 7 TTYCS-1(*1) OR
船内LAN (HUB) RJ-45 CO-0.2x2P(*2) 航法装置 保安警報発呼器 保安警報発呼器 保安警報発呼器
LAN RD-A 8 8 NAV EQUIPMENT
パソコンなど Ethernet CABLE 1 SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
E_TD_P RD-B 9 9
PC: CROSS CABLE P TTYCS-4(*1) OR IC-307 (No.1) *2 *7 IC-307 (No.2) IC-307 (No.3)
LAN(HUB) OR PC, ETC. 2 E_TD-N GND 10 10 *2 *7 *2 *7
HUB: STRAIGHT CABLE CO-0.2x5P(*2)
3 E_RD_P DMC_OUT-H 11 11 DMC_OUT-H 1 SSAS_OUT-H 1 1
4 NC DMC_OUT-C 12 12 DMC_OUT-C 2 NC 2 2
B P
5 NC DMC_CHECK 13 13 DMC_IN-H
P
3 SSAS_CHECK 3 3
P
6 E_RD_N DMC_IN-C 14 14 DMC_IN-C 4 SSAS_IN-C 4 4
7 NC DMC_CTRL 15 15 DMC_CTR 5 SSAS_CTRL 5 5
8 NC 6 GND 6 6

最大3台まで接続可能。
*3 17JE-13090 17JE-23090 TTYCS-4(*1) OR 合計 :最大200m MAX.3 SETS AVAILABLE.
*3 17JE-23250 *2
DTE -02(D8C) 17JE-573-10,5m,φ8 -02(D8C) 遭難警報装置 DMC-5 CO-0.2x5P(*2) TOTAL: UP TO 200m
24VDC プリンタ 57-3036 -02(D8C) PRINTER パソコン DISTRESS MESSAGE
VCTF-0.75x3C PRINTER CO-0.2x5P,MAX.15m
RH12BPG-3S J1 1 1 1 1 NC PC CONTROLLER
5m,φ6.9 アカ RED 1 +24V PP-510 *5 *1
24 VDC RXD 2 2 RXD TB5
16S0184,3m,φ8

(16S0084) クロ BLK 2 0V *2 TTYCS-4


TXD 3 3 TXD
P
1 DIST_IN-H
シロ WHT 3 GND 36 25 4 4 DTR 2 DIST_IN-C
*4 *4 GND 5 5 GND
P
3 DIST_OUT-H
6 6 DSR 4 DIST_OUT-C
7 7 RTS 5 DIST_CTR
8 8 CTS 6 GND
9 9 NC
2B03 16P0209
FUSE *4 *4
15A(12V) *3
MJ-A3SPF 12-24VDC
C 12-24 VDC MJ-A3SPF0018-050Z,5m,φ11 7A(24V)
シロ WHT 1 DC(+) DTE 17JE-13090
-02(D8C)
クロ BLK 2 DC(-) 1 *2 FM14-7P
CO-0.2x2P,MAX.15m
3 GND RXD 2 1 RXD EGCプリンタ
TXD 3 2 TXD EGC PRINTER
100-115/ *1 2B10 16P0214 08S0157,3m
200-230 VAC
4 3 0V PP-505 (+) 1 24VDC
DPYC-2.5 *2
1φ,50/60Hz 24VDC + GND 5 (-) 2
AC_IN GND 銅板
AC/DC OUTPUT - W=30 COPPER STRAP 6 7 NC
*1 GND
電源ユニット 05-003-0031,1.2m 7
08S0087
24 VDC DPYC-4
+ 24VDC AC/DC POWER 8
- INPUT SUPPLY UNIT 9 FM14-5P FM14-7P *2 FM14-7P
CO-0.2x5P,MAX.100m
PR-240-CE *2 *4
1 RXD 1 1 RXD-H EGCプリンタ
2 TXD 2
P
2 TXD-H EGC PRINTER
PE,IV-1.5SQ. 3 NC 3 3 FG PP-505 *2 *6
保護アース P
4 NC 4 4 TXD-C
5 5 5 08S0157,3m
0V *2 RXD-C (+) 1 24VDC
I/F BOX 6 6 +9V (-) 2
注記 OP16-14 7 7 NC
GND
*1)造船所手配。 08S0087
*2)オプション。
D *3)工場にて取付済み。
*4)コネクタクランプでアースに落とす。
*5)ユーザー手配。
*6)TB基板(16P0116)が必要。
*7)終端のIC-307はジャンパー設定を変更する。

NOTE DRAWN TITLE


*1. SHIPYARD SUPPLY. Jul. 13 '05 E.MIYOSHI FELCOM 15
*2. OPTION. CHECKED 名称 インマルサットC船舶地球局
*3. FITTED AT FACTORY.
TAKAHASHI.T
APPROVED
*4. GROUND THRU CONNECTOR CLAMP. Y. Hatai 相互結線図
*5. USER SUPPLY. SCALE MASS NAME
*6. TB BOARD (16P0116) REQUIRED. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 kg INMARSAT-C MES
*7. CHANGE SETTING OF JUMPER IN IC-307 FOR TERMINATOR. CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No.
C5635-C01- J INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
1 2 3 4

アンテナユニット
ANTENNA UNIT 通信制御ユニット
IC-116 ケーブル:コネクタ、選択 COMMUNICATION UNIT *3 *3
CABLE: CONNECTOR, SELECTED IC-216 17JE-13090 17JE-23090 パソコン
DTE -02(D8C) *2 -02(D8C) PC *4
12D-SFA-CV,100m,φ20: N-P-12DSFA 17JE-573-10,5m,φ8
A GND 8D-FB-CV,50m,φ14.3: N-P-8DFB 1 1 NC
RW-4747 TPA5FB0.3NJ5 2 2
FBA-5DFB,0.3m RXD RXD
0.37m TXD 3 3 TXD

TNCP-NJ
4 4 DTR
GND 5 5 GND
TP5FBAW-5DFBB,30m,φ10.7 ANT 6 6 DSR
TP58A15W-RG58,15m,φ5 7 7 RTS
8 8 CTS
9 9 NC
2B02 16P0208B

FUSE *3 接続箱 IC-315


10A:12VDC SSAS D-sub15P JUNCTION BOX
*3 *5
FM-C3FP 12-24VDC 付属ケーブル,2m
5A:24VDC Vcc(6.5V) 1 1 Vcc
12-24 VDC FM-C3FPS-002,3.5m,φ7.5 ATTACHED CABLE
アカ RED 1 DC(+) GND 2 2 GND
クロ BLK 2 DC(-) TX/RX-A 3 3 TD/RD-A
3 GND TX/RX-B 4 4 TD/RD-B
5 5 NC
2B10 16P0227
6 6 TD-A
B 100-115/ *1
200-230 VAC DPYC-2.5 7 7 TD-B 保安警報発呼器 保安警報発呼器 保安警報発呼器
1φ,50/60Hz 24VDC + 8 8 RD-A SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
AC_IN
AC/DC OUTPUT - 9 9 RD-B IC-307 (No.1) *5 IC-307 (No.2) IC-307 (No.3)
*1 10 10 GND *5 *6
DPYC-4 電源ユニット *2 *5 *6
24 VDC + 24VDC AC/DC POWER SSAS_OUT-H 11 11 DMC_OUT-H 1 SSAS_OUT-H 1 1
- INPUT SUPPLY UNIT 12 12 DMC_OUT-C 2 NC 2 2
P
PR-240-CE *2 SSAS_CHECK 13 13 DMC_IN-H 3 SSAS_CHECK 3 3
P
*3 SSAS_IN-C 14 14 DMC_IN-C 4 SSAS_IN-C 4 4
PE,IV-2SQ. SSAS_CTRL 15 15 DMC_CTR 5 SSAS_CTRL 5 5
保護アース 6 6 6
GND
GND 銅板
W=30 COPPER STRAP 最大3台まで接続可能
05-003-0031,1.2m MAX. 3 UNITS AVAILABLE
TTYCS-4(*1) OR CO-0.2x5P(*2)
合計:最大200m
注記 TOTAL: UP TO 200m
*1)造船所手配。
*2)オプション。
*3)工場にて取付済み。
*4)ユーザー手配。 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
C *5)SSAS仕様時標準支給。
*6)終端のIC-307はジャンパー設定を変更する。
DRAWN TITLE
Jul. 13 '05 E..MIYOSHI FELCOM 16
NOTE
CHECKED 名称
*1. SHIPYARD SUPPLY. TAKAHASHI.T インマルサットMINI-C携帯移動地球局
*2. OPTION.
APPROVED Y. Hatai
*3. FITTED AT FACTORY. 相互結線図
*4. USER SUPPLY.
SCALE MASS NAME
*5. STANDARD SUPPLY FOR SSAS SPEC. kg INMARSAT MINI-C MES
*6. CHANGE SETTING OF JUMPER IN IC-307 FOR TERMINATOR.
S-2

DWG No.
C5638-C01- H INTERCONNECTION DIAGRAM
1 2 3 4 5 6 S-3

アンテナユニット インターフェイス *3
ANTENNA UNIT 通信制御ユニット I/F UNIT
COMMUNICATION UNIT PC/DATA *1 *7

NJ-8DFB-1
IC-112 ケーブル:コネクタ(選択) 17JE-23090-02(D8C) 17JE-23250-02(D8C) RS-232C KS-10PT RS-422
RW-4747
CABLE: CONNECTOR (SELECTED) IC-212 J5 17JE-573-10,5m,φ8 J3
12D-SFA-CV,100m: N-P-120DSFA ANT 1 1 FG DATA OUT(+)
0.37m 8D-FB-CV,50m: N-P-5DFB J1 TXD 2 2 RD DATA OUT(-)
N-H1054,0.3m 5D-FB-CV,30m: N-P-5DFB-1 3 3
RXD SD CONT OUT(+)
4 4 CS CONT OUT(-) *2
5 7 TTYC-1 RS-422 データ出力装置
A GND
6 6
SG
ER
DATA IN(+)
DATA IN(-)
RS-422 DATA
NMEA 7 5 RS CONT IN(+)
航法装置 TTYCS-4(*2) OR SRCN-6A16-10P J6 8 8 CONT IN(-)
CO-0.2x2P 1 9 20 *2
NAV EQUIPMENT TXD-H FG
P DPYC-1.5
(NMEA0183) 2 TXD-C 25 SG 100VAC,1φ,50/60Hz
*4
3 RXD-H *4
P
4 RXD-C
*1 *1
*4 10 PC/DATA 17JE-23090-02(D8C) 17JE-13090-02(D8C)
J1
保安警報発呼器インターフェイス
17JE-573-10,5m,φ8 SSAS ALERT UNIT I/F 保安警報発呼器 保安警報発呼器 保安警報発呼器
OR 1 IC-312 SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
2 TXD *3 IC-307 (No.1) IC-307 (No.2) IC-307 (No.3)
着信指示器 IC-303 DTE-2
RCV BZ 3 RXD TB TB *3 *6 TB *3 *6 TB *3 *6
RECEIVED CALL UNIT *2 SRCN-6A16-7P J7 4 SSAS_OUT-H 1 1 SSAS_OUT-H 1 SSAS_OUT-H 1 SSAS_OUT-H
16P0150 TTYCS-4
TB 1 1 RBOUT-H 5 GND NC 2 2 NC 2 NC 2 NC
P P
2 2 RBOUT-C 6 SSAS_CHECK 3 3 SSAS_CHECK 3 SSAS_CHECK 3 SSAS_CHECK
P
3 3 RBIN-H 7 SSAS_IN-C 4 4 SSAS_IN-C 4 SSAS_IN-C 4 SSAS_IN-C
P
4 4 RBIN-C 8 SSAS_CTRL 5 5 SSAS_CTRL 5 SSAS_CTRL 5 SSAS_CTRL
5 5 RBCTR 9 GND 6 6 GND 6 GND 6 GND
SHIELD 6 6
*4 7 *2
B FUSE
MJ-A3SPFD 24VDC TTYCS-4,φ16.3 OR CO-0.2x5P
MJ-A3SPF0016 0.5A シロ WHT 1 合計 :最大200m
24VDC +24V
遭難警報発呼器 IC-302 DMC1 3.5m,φ11 クロ BLK 2 TOTAL:MAX.200m
DISTRESS ALERT UNIT 0V
*2 SRCN-6A16-7P 3
TTYCS-4 J8 GND
16P0150 1 第2端末装置用
TB 1 P
DMCOUT-H
2 2 DMCOUT-C FOR SECOND DTE
3 3 DMCIN-H DTE-2 *1 *1
P 17JE-23090-02(D8C) 17JE-13090-02(D8C) *1
4 4 DMCIN-C COM1 ターミナル 17JE-23250-02(D8C)
J4 17JE-573-10,5m,φ8 *1
5 5 DMCCTR 1 1 DCD ユニット 57-3036
6 TERMINAL UNIT 16S0184,3m,φ8 プリンタ
SHIELD 6 TXD 2 2 RXD PRINTER
*4 7 RXD 3 3 TXD IB-581/582
4 4 DTR *3
GND 5 5 GND *1
DMC2 6 6 DSR FM14-2P
遭難警報発呼器 IC-302 *2 SRCN-6A16-7P 7 7 VCTF-0.75x2C,3m,φ7 24VDC
DISTRESS ALART UNIT TTYCS-4 J9 RTS
1 DMCOUT-H 8 8 CTS
同上 P
2 DMCOUT-C 9 9 R1
SAME AVOBE 3 FM14-7P
P DMCIN-H *4 *4 FM14-5P I/F BOX
4 GND CO-0.2x5P,MAX.100m
DMCIN-C 08S0087,2m OP16-14 *3
5 EGCプリンタ *2
C 6
DMCCTR
CO-0.2x2P,MAX.15m
FM14-7P
EGC PRINTER DPYC-1.5 24VDC
*4 7 PP-505 *3
メイン端末装置用
FOR MAIN DTE ターミナルユニット
DTE-1 *1 *1 TERMINAL UNIT IB-581/582
17JE-23090-02(D8C) 17JE-13090-02(D8C) COM1 KEYBOARD キーボード
J3 17JE-573-10,5m,φ8
1 1 DCD NC 1 KEYBOARD
TXD 2 2 RXD DATA 2 BTC-5100C PS/2
*1 RXD 3 3 TXD VCC 3
HS16P-4 J2 24VDC 4 4 DTR GND 4
シロ WHT 1 +24V GND 5 5 GND NC 5
シロ WHT 2 +24V 6 6 DSR CLOCK 6
クロ BLK 3 0 V 7 7 RTS *4 *1
VCTF-1.25x4C,3m,φ11.5

クロ BLK 4 0 V 8 8 CTS *1 プリンタ


PRINTER 17JE-23250-02(D8C)
9 9 R1 CN3 57-3036 PRINTER
16S0184,3m,φ8
100/110/ *2 AC/DC電源ユニット *4 *4
1 1 PP-510 *3
200/220 VAC DPYC-1.5

57FE-336-205W
AC/DC POWER 24VDC

16S0083,0.2m
*1

1 +24V
INPUT SUPPLY UNIT

Dsub36P *1

Dsub36P *1
1φ,50/60Hz

24VDC

3 GND
VCTF-0.75x2C,3m,φ7

FM14-2P J1

2 0V
*2 PR-300 *3 *5 1 25 36

プリンタ切替器
PRINTER SWITCH
シロ WHT (+)

KSA-CE412L *3

J1
24 VDC DPYC-4 + 24VDC 24VDC +
GND 銅板 2
D (-)
16S0042

W=30 COPPER STRAP クロ BLK *4 *4


- INPUT OUTPUT - 05-003-0031,1.2m

5m

RM12BPG-3S
GND

アカ RED
クロ BLK
シロ WHT
GND *2 08S0087,2m
05S0441

IV-8SQ.

24 VDC VCTF-0.75x3C,5m,φ7
16S0084
注記 NOTE
DRAWN TITLE
*1)工場にて取付済み。
*2)造船所手配。
*1. FITTED AT FACTORY.
*2. SHIPYARD SUPPLY. Jun. 3 '04 K.MIYAZAWA FELCOM 12
*3)オプション。 *3. OPTION. CHECKED
TAKAHASHI.T
名称 インマルサットC船舶地球局
*4)コネクタクランプでアースに落とす。 *4. GROUND THRU CONNECTOR CLAMP.
*5)船内電源に応じてタップを替える。 *5. CHANGE TAP CONNECTION IN ACCORDANCE WITH AC MAINS. APPROVED Y. Hatai 相互結線図
*6)2台または3台接続可能。 *6. 2 OR 3 SETS CAN BE CONNECTED.
SCALE MASS NAME
終端のIC-307はジャンパー設定の変更が必要。 CHANGE JUMPER SETTING IN LAST IC-307.
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 kg INMARSAT-C MES
*7)コネクタの取り替えが必要。 *7. REPLACE CONNECTOR.
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No.
C5613-C01- J INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.