OPERATOR'S MANUAL

SHIP SECURITY
ALERT SYSTEM (SSAS)

Model IC-307
(For FELCOM 15/16/18/19)

www.furuno.com
The paper used in this manual
is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN

All rights reserved. Printed in Japan A : MAY 2004


G : JAN . 23, 2015
Pub. No. OME-56351-G
( GREG ) IC-307(SSAS)

0 0 0 1 5 0 3 5 9 1 6
TABLE OF CONTENTS

SYSTEM CONFIGURATION ..................................................................................... ii

1. OVERVIEW OF SSAS .......................................................................................... 1

2. INSTALLATION .................................................................................................... 3
2.1 Mounting ........................................................................................................................... 3
2.1.1 Junction box (for FELCOM 16/FELCOM 19) ........................................................... 3
2.1.2 SSAS alert unit ......................................................................................................... 4
2.2 Wiring................................................................................................................................ 6
2.2.1 Junction box (for FELCOM 16/19) ........................................................................... 6
2.2.2 SSAS alert unit ......................................................................................................... 7
2.3 Initial Settings ................................................................................................................... 8

3. OPERATION ......................................................................................................... 9
3.1 Operation Mode ................................................................................................................ 9
3.1.1 Changing the password............................................................................................ 9
3.1.2 SSAS manager mode ............................................................................................ 10
3.2 Setting SSAS Report Destination and Message Contents .............................................. 11
3.3 Transmitting SSAS Report .............................................................................................. 14
3.4 Testing the Button ........................................................................................................... 16
3.5 SSAS Report Test ........................................................................................................... 21

4. WATERPROOFING KIT (OPTION) .................................................................... 22

OUTLINE DRAWINGS........................................................................................... D-1


INTERCONNECTION DIAGRAMS .........................................................................S-1

i
SYSTEM CONFIGURATION
Regulations require at least two SSAS alert units.

FELCOM 15

ANTENNA
UNIT
IC-115

DGPS

EGC Printer 24 VDC


100-115/200-230 VAC PP-50
TERMINAL UNIT
1, 50/60 Hz IC-215
AC-DC Power Supply Personal
Computer Printer
24 VDC PR-240-CE*1
(PC/AT compatible)
GPS receiver
12/24 VDC OP16-24 Shipboard LAN (Ethernet)

Printer
24 VDC
PP-510

Mini Keyboard Distress Alert/


Received Call Unit
IC-305
SSAS Alert Unit SSAS Alert Unit
IC-307 IC-307 JUNCTION
(Max. 3 units) BOX Alarm Unit
IC-315 IC-306
SSAS Alert Unit
IC-307
Navigator
: Standard Supply
*1 Any AC-DC power supply
: Option
fulfilling requirements of
: Local Supply IEC 60945 may be used.

FELCOM 16

ANTENNA
UNIT
IC-116

100-115/200-230 VAC AC-DC PRINTER


1, 50/60 Hz Power Supply
PR-240-CE COMMUNICATION UNIT IC-216
24 VDC (with internal GPS receiver)
FURUNO INMARSAT MINI-C MOBILE EARTH STATION
PERSONAL
ER

R
IN

RO
W

COMPUTER
PO

LO

ER
TX

12/24 VDC O POWER I

(PC/AT compatible)

SSAS Alert Unit SSAS Alert Unit SSAS Alert Unit JUNCTION BOX : Standard
IC-307 IC-307 IC-307 IC-315 : Option
: Local Supply
(Max. 3 units)

ii
FELCOM 18

FELCOM 19

ANTENNA
UNIT
IC-119
AC-DC
Power Supply
PR-240
SHIP'S MAINS
12-24 VDC PERSONAL
COMPUTER
(Windows OS)
COMMUNICATION UNIT IC-219
(with internal GPS receiver)
* At least two SSAS Alert Units
JUNCTION BOX are required.
IC-318
NAVIGATOR
(GLONASS
SSAS ALERT UNIT compliant)
IC-307*

SSAS ALERT UNIT


IC-307*

iii
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15/FELCOM 18 or the Inmarsat Mini-C FELCOM 16/FELCOM 19 for the purpose
of alerting specified addresses (for example, your ship’s company) that your ship is under
attack by intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more
constructed before 01 July 2004 to install an SSAS.

When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.

The SSAS is protected with a password to prevent unauthorized setting or testing of it by


other than the ship’s captain or authorized personnel.
Inmarsat System

Ship Name, MMSI No.,


Ship Position, etc.

Headquarters

Ship

Ship's Company,
Management Company

1
SSAS operation flow

1. Open the cover of the button and then press the button.
(This is a latch-type button; hit and release to activate the button.)

2. If addresses have been preset, the SSAS report is sent to one


address 30 seconds after the button is activated.
(Max. 5 addresses)

(You may cancel transmission of the SSAS report by pressing the


button again within 30 seconds of the initial press.)

3. An LES sends acknowledgement to your ship.
4. Steps 2-3 and are repeated in case of multiple addressees.

5. Continuous transmission of the SSAS report begins.
(The interval at which to transmit the SSAS report to each address
can be specified. The SSAS report is continuously transmitted
while the button is ON, at the interval selected.)

6. To stop transmission, press the button again to deactivate it.
(This is only possible in the SSAS manager mode. See
paragraph 3.1.)

2
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16/FELCOM 19)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16/FELCOM
19; it is already installed on the FELCOM 15/FELCOM 18.

Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.

IC-315 IC-318
Standard compass: 1.0 m Standard compass: 0.90 m
Steering compass: 0.7 m Steering compass: 0.60 m

1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.

120 0.5

70 0.5

Junction box IC-315/318


The junction box is connected to the communication unit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.

3
2.1.2 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.

Standard compass: 0.70 m


Steering compass: 0.45 m

Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.

Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.

Clamp

Turn

Fasten three screws.

4. Run the cable thru one of the cable entrances and connect it to terminal board.

4
5. Attach the switch cover as shown below. Note that the cover may also be rotated 180
degrees.
Press here and hold down for five seconds.

Switch cover

Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-7201-1 100-317-931 1
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-802-080 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws
(supplied).
4. Attach switch cover as shown above.

5
2.2 Wiring
2.2.1 Junction box (for FELCOM 16/19)
Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16, or the
junction box IC-318 to connect the SSAS alert unit to the FELCOM 19. Unfasten four
screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.

For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equivalent, see
next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the
CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with the junction box. For connecting the communication unit
IC-216, use cable 16S0344.

IC-315 IC-318
1 Vcc 1 Vcc

IC-305/306

IC-305/306
2 GND 2 GND
3 TD/RD-A 3 TD/RD-A
4 TD/RD-B 4 TD/RD-B
Cover 5 NC 5 NC
6 TD-A(NAV) 6 ALM-H
7 TD-B(NAV) 7 ALM-C
8 RD-A(NAV) 8 RD-A(NAV)
9 RD-B(NAV) 9 RD-B(NAV)
10 GND 10 GND
11 DMC OUT-H 11 SSAS OUT-H
Cable clamp 12 DMC OUT-C 12 SSAS OUT-C
(top) 13 DMC IN-H 13 SSAS IN-H
14 DMC IN-C 14 SSAS IN-C
15 DMC CTR 15 SSAS CTR
Terminal
board
Communication 1
Unit 2
Cable clamp Cable clamp
(bottom)

3 Core 7 mm
Fold back braided shield onto
sheath and fix by cable clamp.
Procedure
16S0344
1. Insert driver from direction 1 .
15mm 90mm 7mm 2. Tilt slightly toward 2 .

Connect the drain wire of the TTYCSLA cables 3. Insert cable core to 3 .
with the screw and crimp-on lugs provided.
Note 1: Do not insert the cable too
Screw, crimp-on lug deeply, to prevent pinching the sheath.
(pre-fitted at factory)
Note 2: Pull each cable slightly to con-
firm that they are in their holes securely.

IC-318 (inside)

6
2.2.2 SSAS alert unit
Three SSAS alert units can be connected. For wiring, see the illustrations below and the
interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15/18)
and the communication unit (FELCOM 16/19), the wiring of the SSAS is monitored and if in
error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the ERROR
lamp (FELCOM 16/19) flashes.

Junction
Box
IC-307 IC-307 IC-307
(No.1) (No. 2) (No. 3)

Connect wiring to the terminal board 16P0229 inside the SSAS unit. To differentiate
between units in case of multiple unit installation, change jumper block settings as shown
below, in accordance with how many units are installed.
Jumper settings for two IC-307 Jumper settings for three IC-307
Unit No.1 unit*
Jumper No. 2 unit *: Default Jumper Unit No.1 unit* No. 2 unit* No. 3 unit
JP1 No Yes setting JP1 No No Yes
JP2 Yes No JP2 Yes Yes No
No. 1 unit: Unit with two cables connnected to it. No. 1 and No. 2 units: Units with two cables connnected to them.
No. 2 unit: Unit with one cable connnected to it. No. 3 unit: Unit with one cable connnected to it.

Two IC-307: No. 2 Two IC-307: No. 1


Three IC-307: No. 3 Three IC-307: No. 1 and No. 2

16P0229 16P0229
JP1 JP2 JP1 JP2

1 2 3 4 5 6 1 2 3 4 5 6

IC-307 IC-307
Cable Fabrication

Twist shield.
Clamp for cable
CO-SPEVV-SB-C CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
0.2x5P
Cut and tape
unused wires 15 mm 40 mm 10 mm
to prevent short.
 = 16.3 mm
Clamp for cable Armor
TTYCS-4
or equivalent Sheath
Shield
Conductor
S = 0.75 mm2
 = 1.11 mm
Sectional view of cable TTYCS-4

7Wiring inside the SSAS alert unit

7
2.3 Initial Settings
Set up the SSAS as follows:

1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU *** [Main menu]
[ Main Menu ] 1. Remote Box Setup
1. Remote Box Setup 2. External Alarm Setup
2. Internal GPS Setup 3. AMS Setup
Enter JOB No. : 4. Management Profile Setup
Enter JOB No.:

FELCOM 15/16
FELCOM 18/19
3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press
the [Enter] key. The prompt PASSWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then,
the item Main Menu is displayed in reverse video.
5. Press [1], [Enter], [1], [Enter]. One of the following windows appears.

6. Press [1], [Enter]. This enables the SSAS functions.


7. Press the [Esc] key several times to close the menu.

Note: Test the SSAS button and SSAS report for proper operation, referring to paragraphs
3.4 and 3.5, respectively.

8
3. OPERATION
3.1 Operation Mode
There are two menu operating modes:

Normal mode: Menus other than SSAS-related menus are displayed.


SSAS manager mode: The mode is activated by the password entered by the ship’s
captain or authorized personnel. The indication “SSAS Manager
Mode” is shown at the top of the screen when this mode is
activated. All SSAS-related menus are available. Transmission of
the SSAS report may be cancelled in this mode. The equipment
starts up in the normal mode, regardless of the mode in use when
the power is turned off.

3.1.1 Changing the password


The default password is “ship security alert”. Ship’s captain or authorized personnel may
change the password as follows:

1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU *** [Main menu]
[ Main Menu ] 1. Remote Box Setup
1. Remote Box Setup 2. External Alarm Setup
2. Internal GPS Setup 3. AMS Setup
Enter JOB No. : 4. Management Profile Setup
Enter JOB No.:

FELCOM 15/16
FELCOM 18/19
3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then
press the [Enter] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW
PASSWORD appears.
5. Enter new password, using at least six characters, and then press the [Enter] key. The
prompt RETYPE NEW PASSWORD appears.
Note: If less than six characters are entered for the password, the message “Please
use a longer password.” appears. Enter a longer password.
6. Enter new password again and then press the [Enter] key. The message “Password
changed” appears.
7. Press the [Esc] key several times to close the menu.

Note: The SSAS manager mode cannot be unlocked without the proper password.

9
3.1.2 SSAS manager mode
All SSAS-related settings are set in the SSAS manager mode. Do the following to access
this mode.

1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU *** [Main menu]
[ Main Menu ] 1. Remote Box Setup
1. Remote Box Setup 2. External Alarm Setup
2. Internal GPS Setup 3. AMS Setup
Enter JOB No. : 4. Management Profile Setup
Enter JOB No.:

FELCOM 15/16
FELCOM 18/19
3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
Note: If there is no SSAS equipment connected, the message "Command Ignored: No
SSAS button is installed." appears.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode
is activated, and it is flashing.
CAUTION
04-04-20 05:37 (UTC)
SSAS Manager Mode enabled.

<Press ESC key to continue>

5. Press the [Esc] key several times to close the menu. This enables the SSAS manager
mode, which allows you to execute the procedure in paragraph 3.2.

Note: Turn the power off and on again whenever changing SSAS-related settings.

10
3.2 Setting SSAS Report Destination and
Message Contents
When the SSAS is activated, the SSAS report is sent according to the addresses (max. 10)
and message content set with SSAS Report 1 – SSAS Report 10 on the SSAS Report
menu.
Note 1: The destination and message content of an SSAS report varies according to
Administration. Therefore, set them as requested by ship’s authorities. For
information other than ship’s name, MMSI no. and IMN no., set it manually with
“Other Inf.”
Note 2: The equipment must be in the SSAS manager mode to execute this procedure.
See paragraph 3.1.2.
1. Press the [F5] to open the Reports menu.
Reports Reports
1. Data Report 1. Data Report
2. Message Report 2. Message Report
3. Data Network ID 3. Enhanced Pre-Assigned Data Report (EPADR)
4. SSAS Report 4. Data Network ID
5. SSAS Report
FELCOM 15/16
FELCOM 18/19

2. For FELCOM15/19, press the [4] key to show the SSAS Report menu.
For FELCOM 18/19, press the [5] key.
SSAS Report SSAS Report
1. SSAS Report 1 1. SSAS Report Destination
2. SSAS Report 2 2. Message Contents
3. SSAS Report 3
4. SSAS Report 4 FELCOM 18/19
5. SSAS Report 5
6. Message Contents

FELCOM 15/16

3. For FELCOM 15/16, press the appropriate report number ([1] through [5]) to show the
SSAS Report Destination menu.
For FELCOM 18/19, press the [1] key.
SSAS Report Desitnation
Enter: Report Entry ESC: Quit
No Mode Destination Interval

01 Test Only test@test 00:10 Interval is displayed in the


02 hh:mm format.
03 Real+Test 123456789 02:00 Setting range: 00:10 to 99:59
04
05
06 Destination ID or mail address
07
08
09
10 Selected mode (Real+Test,
Real Only, Test Only) is
displayed here

The SSAS Report Destination menu displays any current reports.

11
4. Press the [↑] or [↓] key to choose the report number desired and then press the [Enter]
key to display the selected SSAS report’s details.
SSAS Report SSAS Report
Status ON Status ON
Mode Real+Test Mode Real+Test
Station Name Station Name
Destination Type TELEX Destination Type TELEX/MES
Prefix Code Prefix Code
Country/Ocean Code Country/Ocean Code
Station ID Destination
Modem Type Modem Type
Address Address
Subject Subject
LES ID LES ID
Report Interval 02:00 (hh: mm) Report Interval 02:00

FELCOM 15/16 FELCOM 18/19


5. Press the [↓] key to choose Mode and then press the [Enter] key.

Real+Test
Real Only
Test Only

6. Press the [↑] or [↓] key to choose mode desired and then press the [Enter] key.
“Mode” defines what SSAS report(s) a station is to receive:
Real+Test: Actual SSAS report and test SSAS report.
Real Only: Actual SSAS report only.
Test Only: Test SSAS report only.
7. Press the [↓] key to choose Station Name and then press the [Enter] key.
8. Press the [↑] or [↓] key to choose appropriate station and then press the [Enter] key.
You may sort the list by group name, station name or communication type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or
descending order.
Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or
descending order.
Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in
ascending or descending order.
9. Press the [↓] key to choose LES ID and then press the [Enter] key.
10. Press the [↑] or [↓] key to choose LES and then press the [Enter] key.
Note: Change the LES whenever sea area has changed. However, the equipment
automatically searches for an LES with which you can communicate and the SSAS
report is transmitted to that LES.
11. Press the [↓] key to choose Report Interval and then press the [Enter] key.
12. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]
key.
13. Press the [Esc] key to show the Update window.

Update

Yes No

14. Yes is selected; press the [Enter] key to close the SSAS report window.

12
15. Press the [2] key to display the SSAS Message Contents menu.
SSAS Message Contents
Vessel Name : ______________________________
MMSI : _________
IMN : _________
Other Inf. : _______________________________________________________
_______________________________________________________
_______________________________________________________
LAT: 34: 44. 46N
LON: 135: 21. 26E
Time: 02/04/2012 04:31:48 (UTC)
COURSE: 071 deg
SPEED: 00 kt
Time: 02/04/2012 04:31:48 (UTC)

FELCOM 15/16
SSAS Message Contents
Vessel Name : _ _ _ _ _ _ _ _ _ _____________________
Call Sign : _________
MMSI : _________
IMN : _________
IMO : _________
Other Inf. : ___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
LAT: 34: 44. 46N
LON: 135: 21. 26E
Time: 02/04/2012 04:31:48 (UTC)
COURSE: 071 deg
SPEED: 00 kt
Time: 02/04/2012 04:31:48 (UTC)

FELCOM 18/19

16. Press the [Enter] key to open the Vessel Name window.
17. Enter vessel’s name and then press the [Enter] key.
18. Press the [↓] key to choose MMSI and then press the [Enter] key.
19. Enter MMSI number and then press the [Enter] key.
20. Press the [↓] key to choose IMN and then press the [Enter] key.
21. Enter IMN and then press the [Enter] key.
22. Press the [↓] key to choose Other Inf. and then press the [Enter] key
23. Enter appropriate message (for FELCOM15/16: three lines, for FELCOM18/19: six lines)
and then press the [Enter] key.
Note: To shift between lines, use the [↑] or [↓] key.
24. Press the [Esc] key to show the Update window.
25. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
26. Press the [Esc] key twice to return to the standby display.

Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.”


Note 2: SSAS report settings may be saved to a floppy disk for backup.
FELCOM 15: [F8], [9], [6] to show the Save/Load window.
FELCOM 16: [F8], [8], [6] to show the Save/Load window.
FELCOM 18/19: [F8], [8], [6] to show the Export/Import window.

13
Save to FD Load from FD
1. ALL 1. ALL
2. Station List 2. Station List *: Availlable only in SSAS manager mode
3. LES List 3. LES List
("5.SSAS Report" is added in the SSAS
4. E-Mail Service List 4. E-Mail Service List
5. SSAS Report* 5. SSAS Report* manager mode and item numbers are shifted.)
6. Other 6. Other

FELCOM15/16
Export Import
1. Sent Message 1. Station List
2. Received Message 2. LES List
3. EGC Message 3. E-Mail/SMS Service List
4. Station List 4. Settings
5. LES List
6. E-Mail/SMS Service List
7. Test
8. Maintenance
9. Settings

FELCOM 18/19
Note 3: To confirm the settings, follow paragraph 3.5.

3.3 Transmitting SSAS Report


In the normal mode, the SSAS report is sent 30 seconds after the button on the SSAS is
pressed. The SSAS repeatedly transmits the report even if the button is pushed off ( ).
Repeated transmission can only be stopped from the SSAS manager mode.

1. Open the cover of the SSAS alert button.


2. Push the button. The button is a latch-type button;
hit and release the button to activate ( ) the
SSAS unit.
3. The SSAS report is transmitted 30 seconds after
Cover
the button is pushed in ( ). Below are the
contents of the SSAS report.

- - - SSAS ALERT MESSAGE - - -


Vessel Name: Queen Elizabeth 2 Ship's Name
MMSI: 111660000 MMSI No.
IMN: 443100000 IMN No.
Help me! Desired message
LAT: 34:44.46N Own ship postion in latitude
LON: 135:21.26E Own ship position in longitude
Time: 02/04/2004 04:31:48 (UTC) Time of position data
COURSE: 071 deg Course
SPEED: 00 kt Speed
Time: 02/04/2004 04:31:48 (UTC) Time of course and speed data

FELCOM 15/16

14
- - - SSAS ALERT MESSAGE - - -
Vessel Name: Queen Elizabeth 2 Ship's Name
MMSI: 111660000 MMSI No.
IMN: 443100000 IMN No.
IMO: 123456789 IMO No.
Help me! Desired message
LAT: 34:44.46N Own ship postion in latitude
LON: 135:21.26E Own ship position in longitude
Time: 02/04/2004 04:31:48 (UTC) Time of position data
COURSE: 071 deg Course
SPEED: 00 kt Speed
Time: 02/04/2004 04:31:48 (UTC) Time of course and speed data

FELCOM 18/19

4.An LES sends acknowledgement to your ship.


5.For multiple destinations, steps 3 and 4 are repeated.
6. The SSAS report is transmitted repeatedly while the button remains pushed in ( ).
7. To stop transmission, push the button again to pop it out ( ). (SSAS manager mode
only.)
Note: If transmission is not canceled with the button and the power is turned off, the
equipment resumes repeated transmission when powered again.

How to cancel the transmission when the transmission is erroneously


made (FELCOM15/16/18/19)
Note 1: The SSAS report is sent 30 seconds after the button on the SSAS is pressed.
Note 2: The message shown below appears when the cancellation is made.
CAUTION
14-04-10 05:40 (UTC)
INF: SSAS UNIT activation has been canceled.

Pop-up message

<Within 30 seconds after the button is pressed>


Press the button on the SSAS again to turn it off.

<More than 30 seconds after the button is pressed>


[Method 1]
Note : Do the following procedure on the terminal unit of FELCOM15/18 or PC of
FELCOM16/19.
1. Switch to the SSAS manager mode, referring to paragraph 3.1.2.
2. In case of FELCOM16/18/19, press [F8], [1] to show the [System Setup] menu.
In case of FELCOM15, press [F8], [2] to show the [System Setup] menu.
3. Press [↓] to choose Command Window and then press the [Enter] key.
4. Type “terminate ssas alert” (without quotation marks) in the Enter JOB No. field and then
press the [Enter] key.
[Method 2]
1. Turn the button of all SSAS IC-307s off.
2. Press the button ON→OFF→ON→OFF on one of the above-mentioned SSAS IC-307s

15
3.4 Testing the Button
Note 1: An actual SSAS report cannot be transmitted during the testing.
Note 2: The equipment must be in the SSAS manager mode to conduct the test.

FELCOM 15/18
<In case of not sending the test report>
1. Press the [F7] key to display the Options menu.
2. Press one of the following keys to display the Test menu:
Operating mode is Inmarsat-C: [7] key
FELCOM 18: [8] key
Operating mode is EGC receiver: [6] key

Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test

3. Press the [4] key.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select NCS
Self Test Start
5.4.Ocean Region
Distress Alarm Button Test
6. Test Yes No

4. Press the [Enter] key to start the test.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select
Self NCS
Distress/SSAS
Test buttons are under test mode.
5.4.Ocean Region
Distress Press
Alarm any key
Button CAUTION
Testto escape.
INF: SSAS6.Buttons
Test entered into TEST MODE.

<Press ESC key to continue>

The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent.” appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
Turn the button of the No. 1 SSAS off ( ) within 30 seconds.
Note: Any message does not appear when turning the button off.
7. Close the button cover on the No.1 SSAS.
Note: To test the No. 2 and No. 3 SSAS repeat steps 5 to 9.

16
8. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

If the button remains pushed in ( ), the message “Please return the SSAS button into
OFF-STATE.” appears. Push the button to pop it out.
9. Press the [Esc] key three times to return to the standby display.
Note:If the button is left pushed in ( ) when the terminal unit is turned on, the
equipment displays “Please return the SSAS button into OFF-STATE.” Push the button
again to turn off ( ) the button.

<In case of sending the test report>


1. Press the [F7] key to display the Options menu.
2. Press one of the following keys to display the Test menu:
Operating mode is Inmarsat-C: [7] key
FELCOM 18: [8] key
Operating mode is EGC receiver: [6] key

Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test

3. Press the [4] key.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select NCS
Self Test Start
5.4.Ocean Region
Distress Alarm Button Test
6. Test Yes No

4. Press the [Enter] key to start the test.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select
Self NCS
Distress/SSAS
Test buttons are under test mode.
5.4.Ocean Region
Distress Press
Alarm any key
Button CAUTION
Testto escape.
INF: SSAS6.Buttons
Test entered into TEST MODE.

<Press ESC key to continue>

The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent.” appears.

17
5. Open the button cover on the No.1 SSAS.
6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to
the station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”.
When starting the transmission, [Current State] indicates [SENDING] at the left bottom
on the screen.

Current State : SENDING Returning 94-08-11 10:11(UTC)


NCS:POR LOGIN LAT: 10:00.00N
DCE F18 Ver.01 REC. MESSAGE EXIST LON: 000:00.00E

Note: The SSAS test report is not sent to the station(s) whose Mode set on the SSAS
Report window is “Real Only”..
8. Turn the button of the No. 1 SSAS off ( )
9. Close the button cover on the No.1 SSAS.
Note: To test the No. 2 and No. 3 SSAS repeat steps 5 to 9.
10. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

If the button remains pushed in ( ), the message “Please return the SSAS button into
OFF-STATE.” appears. Push the button to pop it out.
11. Press the [Esc] key three times to return to the standby display.
Note:If the button is left pushed in ( ) when the terminal unit is turned on, the
equipment displays “Please return the SSAS button into OFF-STATE.” Push the button
again to turn off ( ) the button.
12. When the SSAS test report is successfully sent, “Successful Sending message” and
“DELIVERY CONFIRMED:A specified email address” messages are shown below.
CAUTION
94-08-11 00:38(UTC)
Successful Sending message.
94-08-11 00:41(UTC)
DELIVERY CONFIRMED: xxxxxx@xx.xx.jp
<Press ESC key to continue>

13. Confirm that the SSAS test report is sent to the station(s).

18
FELCOM 16/19 (no PC)

Turn off communication unit.

Turn on button of No. 1 SSAS.

Turn on communication unit.

30 s

POWER, LOGIN and TX lamps flash


in that order.

Send SSAS No (within 30 s)


test report?

Yes (after 30 s)
SSAS report is sent to station(s)
whose mode is "Real+Test" or "Test
Only". (See paragraph 3.2.)
Lamps flash rapidly during TX. It takes Test TX
2 to 5 minutes to send one message.

Test No ERROR lamp flashes rapidly.


successful?

Yes

POWER, LOGIN and TX lamps flash in


that order. ERROR lamp also flashes.

Turn off button of No. 1 SSAS.

The POWER, LOGIN and TX lamps flash


in that order.

Turn on button of No.2 SSAS.

Test TX

Turn off button of No.2 SSAS.

Note: If a 3rd SSAS unit is installed


test it by procedure used to test
Turn communication unit off and No.2 unit.
on again.

19
FELCOM 16/19 (by PC)
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu. For FELCOM 19, press the [8] key.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test

3. Press the [4] key.


Options
1. Login Test
2.1.Logout
PV Test SSAS Button Test
3.2.Abort
PV Test Result
4.3.Select NCS
Self Test Start
5.4.Ocean Region
Distress Alarm Button Test
6. Test Yes No

4. Press the [Enter] key to start the test.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select
Self NCS
Distress/SSAS
Test buttons are under test mode.
5.4.Ocean Region
Distress Press
Alarm any key
Button CAUTION
Testto escape.
INF: SSAS6.Buttons
Test entered into TEST MODE.

<Press ESC key to continue>

Test mode
The display shows the message (in red) “SSAS buttons are under test. Cancel the test
mode if a real SSAS alert needs to sent.” appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button in (ON). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the
station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”.
8. Turn the button of the No. 1 SSAS off ( ).
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.

20
9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

Further, because the button remains pushed in ( ), the message “Please return the
SSAS button into OFF-STATE.” appears.
10. Push the button again to pop it out ( ).
11. Close the button cover.
12. Press the [Esc] key three times to return to the standby display.

Note: If the button is left pushed in ( ) when the communication unit is turned on, the
equipment will go into the test mode if the SSAS is not transmitting repeatedly. To
return to the standby display, push the button again to pop it out ( ) and then turn
the communication unit off and on again.

3.5 SSAS Report Test


You can test for successful transmission of the SSAS report to the address you specify,
without using the button. The test report message states “!!! Test Call !!!” to alert the
receiver of the message that it is a test call.

Note: This function is only available in the SSAS manager mode. Switch to this mode (see
paragraph 3.1.2) and then follow this procedure.

1. Access the Report Destination Menu, referring to section 3.2.


2. Set destination where to transmit the test.
3. Press the [↑] key to choose Status and then press the [Enter] key.
4. Press the [↓] key to choose TEST and then press the [Enter] key.
5. Press the [Esc] key to open the Update window.
6. Yes is selected; press the [Enter] key. The test report is transmitted. After it is
transmitted, “Status” is automatically set to ON.
7. Press the [Esc] key twice to return to the standby display.

21
4. WATERPROOFING KIT (OPTION)
To mount the IC-305 and IC-307 on a bulkhead, use the optional waterproofing kit to keep
water splash out of the units.

Note: This kit cannot be used if the IC-305 or IC-307 is mounted face upward.
OP-xx (For IC-305)
Name Type Code No. Qty
Fixing Tape 24-009-1225 100-366-200-10 2

OP-xx (For IC-307)


Name Type Code No. Qty
Waterproofing Cover 16-023-5501 100-374-950-10 1
Fixing Tape 24-009-1225 100-366-200-10 2

1. Unfasten four screws to remove cover of IC-305/IC-307.


2. Attach supplied fixing to the underside of the cover as shown in the illustration below.
Fixing tape

3. Attach the cover.


4. For IC-307, remove the seal from the waterproofing cover and attach the cover as
shown in the illustration below.

22
D-1

Mar.03'05
D-2

17/May/2012 Y.NISHIYAMA
D-3

6/Oct/2010 Y. NISHIYAMA
16/Jun/2014 H.MAKI
D-4
S-1
1 2 3 4 5 6

アンテナユニット
ANTENNA UNIT
IC-115
アラームユニットIC-306
ケーブル/コネクタは選択 ALARM UNIT
RW-4747 SELECT CABLE & CONNECTOR 16P0213D

TNCP-NJ
0.3m
TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA ターミナルユニット 1 VCC
FBA-5DFB,0.4m 8D-FB-CV,50m,φ14.3: N-P-8DFB TERMINAL UNIT P
2 GND
5D-FB-CV,30m,φ10.7: N-P-5DFB IC-215 3 TD/RD-A
A P
4 TD/RD-B
*7 ANT DGPS *1 5 FG
TP5FBAW-5DFBB,30m,φ7.7 BNC PLUG COAX. CABLE(50Ω) DGPSデコーダー
DGPS DECODER
遭難警報器 IC-305 IC-350を接続するとき(IC-305との共用不可)
2B02 16P0208A DISTRESS ALERT/
*3 接続箱 RECEIVED CALL UNIT CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
Dsub15P JUNCTION BOX
KEYBOARD JUNCTION IC-315 *1 16P0213C
キーボード 1.6m 2m TTYCS-4 IC-315 *1
1 KDAT Vcc(ALM) 1 1 1 VCC 選択 INMARSAT No.1/2
KEYBOARD P
SELECT TTYCS-1
2 NC GND 2 2 2 GND 3 1 TR-A
2 TR-B アラームユニット
P
3 GND TD/RD-A 3 3 3 TD/RD-A 4
4 +5V TD/RD-B 4 4
P
4 TD/RD-B 3 FG ALARM UNIT
5 KCLK NC 5 5 5 FG IC-350 *2
6 NC TD-A 6 6
TD-B 7 7 TTYCS-1(*1) OR
CO-0.2x2P(*2) 航法装置 保安警報発呼器 保安警報発呼器 保安警報発呼器
船内LAN (HUB) RJ-45 LAN RD-A 8 8 NAV EQUIPMENT
STP CABLE(CAT5) *1 1 9 9 SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
パソコンなど PC: CROSS CABLE P
E_TD_P RD-B IC-307 (No.1) *2 *6 IC-307 (No.2) IC-307 (No.3)
2 10 10 TTYCS-4(*1) OR
LAN(HUB) OR PC, ETC. HUB: STRAIGHT CABLE E_TD-N GND
CO-0.2x5P(*2) *2 *6 *2 *6
3 E_RD_P DMC_OUT-H 11 11 1 SSAS_OUT-H 1 1
4 DMC_OUT-C 12 12 2 2 2
B P
5
NC
NC DMC_CHECK 13 13
P
3
NC
SSAS_CHECK
P
3
P
3
P P P
6 E_RD_N DMC_IN-C 14 14 4 SSAS_IN-C 4 4
7 NC DMC_CTRL 15 15 5 SSAS_CTRL 5 5
8 NC 6 GND 6 6

17JE-23090 *2 17JE-13090 最大3台まで接続可能。


*3 DTE -02(D8C) 17JE-573-10,5m,φ8 -02(D8C) MAX.3 SETS AVAILABLE.
*3 17JE-23250 パソコン
プリンタ 57-3036 PRINTER CO-0.2x5P,MAX.15m TTYCS-4(*1) OR 合計 :最大200m
RH12BPG-3S 24VDC -02(D8C) 1 1 NC PC
VCTF-0.75x3C,5m,φ7 アカ RED 1 +24V PRINTER 1 1 2 2 CO-0.2x5P(*2) TOTAL: UP TO 200m
24 VDC RXD RXD
(16S0084) クロ BLK 2 0V PP-510 3 3
TXD TXD
16S0184,3m,φ8

シロ WHT 3 GND *2 4 4 DTR


36 25 GND 5 5 GND
6 6 DSR
*4 *4
7 7 RTS
8 8 CTS
9 9 NC
2B03 16P0209
FUSE *4 *4
15A(12V) *3
7A(24V) MJ-A3SPF 12-24VDC
12-24 VDC MJ-A3SPF0018-050ZC,5m,φ11 1 DC(+)
C シロ WHT
クロ BLK 2 DC(-) DTE 17JE-23090
-02(D8C)
3 GND 1 *2 FM14-7P
2 CO-0.2x2P,MAX.15m 1 EGCプリンタ
100-115/ 2B10 16P0214 RXD RXD
*1 TXD 3 2 TXD EGC PRINTER
200-230 VAC DPYC-2.5 08S0157,3m
1φ,50/60Hz AC AC/DC 24VDC + 4 3 0V PP-505 (+) 1 24VDC
*1 IN 銅板 *2
電源ユニット OUT - COPPER STRAP GND 5 (-) 2
24 VDC DPYC-4 + DC AC/DC POWER W=30,1.2m 6 7 NC
- IN GND
SUPPLY UNIT 7 *4 08S0087
E PR-240 *2 8
PE *1 9 FM14-7P *2 FM14-7P
IV-2sq. FM14-5P
CO-0.2x5P,MAX.100m
保護アース *4
1 RXD 1 1 RXD-H EGCプリンタ
2 TXD 2
P
2 TXD-H EGC PRINTER
3 NC 3
P
3 FG PP-505 *2 *5
4 NC 4 4 TXD-C
5 5 5 1 08S0157,3m
0V *2 RXD-C (+) 24VDC
*4 I/F BOX 6 6 +9V (-) 2
OP16-14 7 7 NC
注記 GND
*4 *4 08S0087
*1)造船所手配。
*2)オプション。
D *3)工場にて取付済み。
*4)コネクタクランプでアースに落とす。
*5)TB基板(16P0116)が必要。
*6)終端のIC-307はジャンパー設定を変更する。
*7)アンテナケーブルは切断して使用しないこと。

NOTE DRAWN TITLE


*1. SHIPYARD SUPPLY. 20/Nov/2012 T.YAMASAKI FELCOM 15
CHECKED
*2. OPTION.
20/Nov/2012 T.TAKAHASHI
名称 インマルサットC船舶地球局
*3. FITTED AT FACTORY. APPROVED
*4. GROUND THRU CONNECTOR CLAMP. 20/Nov/2012 Y.NISHIYAMA 相互結線図
*5. TB BOARD (16P0116) REQUIRED. SCALE MASS NAME
*6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 kg INMARSAT-C MES
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No.
*7. DO NOT SHORTEN ANTENNA CABLE. C5635-C01- T INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
1 2 3 4

アンテナユニット
ANTENNA UNIT
IC-116 通信制御ユニット *3 *3
COMMUNICATION UNIT 17JE-13090 17JE-23090 パソコン
ケーブル/コネクタは選択 IC-216 DTE -02(D8C) *2 -02(D8C) PC
RW-4747 SELECT CABLE & CONNECTOR 1 17JE-573-10,5m,φ8 1 NC
0.3m TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA 2 2
FBA-5DFB,0.4m RXD RXD
A 8D-FB-CV,50m,φ14.3: N-P-8DFB TXD 3 3 TXD

TNCP-NJ
5D-FB-CV,30m,φ10.7: N-P-5DFB 4 4 DTR
*6 GND 5 5 GND
TP5FBAW-5DFBB,30m,φ7.7 ANT 6 6 DSR
TP58A15W-RG58,15m,φ5 7 7 RTS
8 8 CTS
9 9 NC
2B02 16P0208B

FUSE *3 接続箱 IC-315


SSAS D-sub15P JUNCTION BOX
10A:12VDC *3 *4
FM-C3FP 12-24VDC 1 2m
5A:24VDC Vcc(6.5V) 1 Vcc
12-24 VDC FM-C3FPS-002,3.5m,φ7.5 アカ RED 1 DC(+) GND 2 2 GND
クロ BLK 2 DC(-) TX/RX-A 3 3 TD/RD-A
3 GND TX/RX-B 4 4 TD/RD-B
NC 5 5 NC
2B10 16P0227
NC 6 6 TD-A
100-115/ *1 7
200-230 VAC DPYC-2.5 NC 7 TD-B
NC 8 8 RD-A 保安警報発呼器 保安警報発呼器 保安警報発呼器
1φ,50/60Hz ACAC/DC 24VDC + SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
B IN電源ユニット OUT - NC 9 9 RD-B
IC-307 (No.1) IC-307 (No.2) IC-307 (No.3)
*1 NC 10 10 GND *4
DPYC-4 AC/DC POWER *4 *5 *2 *5
24 VDC + DC SUPPLY UNIT SSAS_OUT-H 11 11 DMC_OUT-H 1 SSAS_OUT-H 1 1
- IN PR-240 *2 NC 12 12 DMC_OUT-C 2 NC 2 2
P P P
SSAS_CHECK 13 13 DMC_IN-H 3 SSAS_CHECK 3 3
PE *1 P P P
SSAS_IN-C 14 14 DMC_IN-C 4 SSAS_IN-C 4 4
IV-2sq. 15 5 5
保護アース SSAS_CTRL 15 DMC_CTR 5 SSAS_CTRL
6 GND 6 6
銅板 COPPER STRAP
W=30,1.2m 最大3台まで接続可能
MAX. 3 UNITS AVAILABLE
TTYCS-4(*1) OR CO-0.2x5P(*2)
合計:最大200m
TOTAL: UP TO 200m
注記
*1)造船所手配。
*2)オプション。
*3)工場にて取付済み。
*4)SSAS仕様時標準支給。 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
C *5)終端のIC-307はジャンパー設定を変更する。
*6)アンテナケーブルは切断して使用しないこと。
DRAWN TITLE
30/Mar/2010 T.YAMASAKI FELCOM 16
NOTE
CHECKED 名称
*1. SHIPYARD SUPPLY. 30/Mar/2010 T.TAKAHASHI インマルサットMINI-C携帯移動地球局
*2. OPTION.
APPROVED
*3. FITTED AT FACTORY. 1/Apr/2010 Y.NISHIYAMA 相互結線図
*4. STANDARD SUPPLY FOR SSAS SPEC.
SCALE MASS NAME
*5. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. kg INMARSAT MINI-C MES
*6. DO NOT SHORTEN ANTENNA CABLE.
S-2

DWG No.
C5638-C01- L INTERCONNECTION DIAGRAM
S-3
1 2 3 4 5 6

アラームユニット
1 VCC ALARM UNIT
P
2 GND IC-306
3 TD/RD-A *2
P
4 TD/RD-B
アンテナユニット GND
ANTENNA UNIT 5
IC-118
ターミナルユニット IC-350を接続するとき(IC-305との共用不可)
TERMINAL UNIT 接続箱 遭難警報器
A

TNCP-NJ
TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA IC-218 JUNCTION BOX DISTRESS ALERT/ *2 CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
FBA-5DFB,0.4m 8D-FB-CV,40/50m,φ14.3: N-P-8DFB JUNCTION 17JE-23150 RECEIVED CALL UNIT
IC-318
5D-FB-CV,30m,φ10.7: N-P-5DFB -02(D8C) 2m TTYCSLA-4(*1) OR CO-0.2x5P(*2) IC-305 IC-318
Vcc(ALM) 1 1 1 VCC 選択 TTYCSLA-1(*1) OR INMARSAT No.1/2
ANT P CO-0.2x2P(*2)
GND 2 2 2 GND SELECT 3 1 TR-A
TP5FBAW-5DFBB,30m,φ7.7 TD/RD-A 3 3 3 TD/RD-A 4 2 TR-B アラームユニット
TD/RD-B 4 4
P
4 TD/RD-B 3 FG ALARM UNIT
NC 5 5 TTYCSLA-1(*1) OR 5 GND IC-350
DGPS CO-0.2x2P(*2) アラームシステム
BNC ALM-H 6 6
DGPSデコーダー COAX. CABLE(50Ω) ALM-C 7 7 TTYCSLA-1(*1) OR ALARM SYSTEM
DGPS DECODER RD-A 8 8 CO-0.2x2P(*2) 航法装置 保安警報発呼器
USB RD-B 9 9 NAV EQUIPMENT SSAS ALERT UNIT
A TYPE IC-307 *2 *3 *4 IC-307(No.2) IC-307(No.3)
GND 10 10
キーボード 1.5m 4
TTYCSLA-4(*1) OR CO-0.2x5P(*2)
KEYBOARD SSAS_OUT-H 11 11 1 SSAS_OUT-H 1 *2 *3 *4 1 *2 *3
SSAS_OUT-C 12 12 2 NC 2 2
P P P
SSAS_CHECK 13 13 3 SSAS_CHECK 3 3
SSAS_IN-C 14 14 4 SSAS_IN-C 4 4
17JE-23250 P P P
PRINTER SSAS_CTRL 15 15 5 SSAS_CTRL 5 5
RH12BPG-3S 57-3036 -02(D8C)
プリンタ 36 6 GND 6 6
VCTF-0.75x3C,5m,φ7 3
16S0184 25
24 VDC (+) アカ RED PRINTER
(-) クロ BLK (16S0084) PP-510 *2 3m,φ8 *1
B GND シロ WHT または OR IV-2sq. 最大3台まで接続可能
H230817-1(*2) LAN RJ45 MAX. 3 UNITS AVAILABLE.
*1 *1 TTYCSLA-4(*1) OR
防水仕様ケーブル 8
STP(CAT5) パソコン/HUB CO-0.2x5P(*2)
WATERPROOF CABLE
12 VDC DC/DCコンバータ PC OR HUB 合計 :最大200m
DC/DC CONVERTER TOTAL: UP TO 200m
15A(12V) DC IN
7A(24V) MJ-A3SPF
MJ-A3SPF0018-050Z
12-24VDC シロ WHT 1 DC+
5m,φ11
クロ BLK 2 DC-
3 GND
100-115/ *1
200-230 VAC DPYC-2.5
1φ,50/60Hz AC AC/DC 24VDC + 防水仕様ケーブル
*1 IN 銅板 接続箱
電源ユニット OUT - COPPER STRAP IC-218 WATERPROOF CABLE
24 VDC DPYC-4 + DC AC/DC POWER JUNCTION BOX
W=30,1.2m *2
- IN SUPPLY UNIT JUNCTION XM-FD-361,2m IC-318
E PR-240 *2 1 アオ BLU 1
PE *1 2 チャ BRN 2
IV-2sq. 3 ムラサキ PPL 3
保護アース ハイ GRY
4 4
5 5
C 6 ミドリ GRN 6
7 キ YEL 7
8 ダイ ORG 8
9 モモ PNK 9
10 ウスミドリ L-GRN 10
11 シロ/クロ WHT/BLK 11
12 シロ/アカ WHT/RED 12
13 クロ BLK 13
14 アカ RED 14
15 ミズ L-BLU 15

D
注記
*1)造船所手配。
*2)オプション。
*3)終端のIC-307はジャンパー設定を変更する。 DRAWN TITLE
*4)SSAS仕様のとき標準構成。 12/Dec/2012 T.YAMASAKI FELCOM 18
CHECKED 名称
NOTE 12/Dec/2012 H.MAKI インマルサット-C 船舶地球局
*1: SHIPYARD SUPPLY. APPROVED
18/Dec/2012 Y.NISHIYAMA 相互結線図
*2: OPTION.
SCALE MASS NAME
*3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 kg INMARSAT-C MES
*4: STANDARD CONFIGURATION FOR SSAS. CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No. REF.No.
C5674-C01- D 16-023-3001-1 INTERCONNECTION DIAGRAM
1 2 3 4

アンテナユニット
ANTENNA UNIT
IC-119 通信制御ユニット
TPA5FB0.4NJ5 COMMUNICATION UNIT 接続箱
FBA-5DFB,0.4m IC-219 JUNCTION BOX
JUNCTION 17JE-23150
12D-SFA-CV,100m,φ20: N-P-12DSFA IC-318 *2 *4
8D-FB-CV,50m,φ14.3: N-P-8DFB -02(D8C) 2m
Vcc(ALM) 1 1

TNCP-NJ
5D-FB-CV,30m,φ10.7: N-P-5DFB TTYCSLA-1(*1) OR
A ANT GND 2 2 航法装置
TD/RD-A 3 3 CO-0.2x2P(*2)
TP5FBAW-5DFBB,30m,φ7.7 NAV EQUIPMENT
TD/RD-B 4 4
NC 5 5 TTYCSLA-1(*1) OR
CO-0.2x2P(*2) アラームシステム
ALM-H 6 6 ALARM SYSTEM
ALM-C 7 7
RD-A 8 8 保安警報発呼器
RD-B 9 9 SSAS ALERT UNIT
GND 10 10 TTYCSLA-4(*1) OR IC-307 *2 *3 *4 IC-307(No.2) IC-307(No.3)
11 CO-0.2x5P(*2) *2 *3
SSAS_OUT-H 11 1 SSAS_OUT-H 1 *2 *3 *4 1
SSAS_OUT-C 12 12 2 NC 2 2
P P P
SSAS_CHECK 13 13 3 SSAS_CHECK 3 3
SSAS_IN-C 14 14 4 SSAS_IN-C 4 4
P P P
SSAS_CTRL 15 15 5 SSAS_CTRL 5 5
6 GND 6 6
*1
10A(12V) DC IN IV-2sq. 最大3台まで接続可能
5A(24V) MJ-A3SPF LAN MAX. 3 UNITS AVAILABLE.
MJ-A3SPF0016-035 RJ45 *1 TTYCSLA-4(*1) OR
12-24VDC シロ WHT 1 DC+ 8
3.5m STP(CAT5) パソコン/HUB CO-0.2x5P(*2)
クロ BLK 2 DC-
PC OR HUB 合計 :最大200m
B 3 GND
TOTAL: UP TO 200m
防水仕様ケーブル 接続箱
100-115/ 銅板 IC-219 WATERPROOF CABLE
*1 JUNCTION BOX
200-230 VAC DPYC-2.5 COPPER STRAP JUNCTION *2
AC AC/DC 24VDC + XM-FD-361,2m IC-318
1φ,50/60Hz W=30,1.2m
*1 IN 電源ユニット OUT - 1 アオ BLU 1
24 VDC DPYC-4 + DC AC/DC POWER 2 チャ BRN 2
- IN SUPPLY UNIT 3 ムラサキ PPL 3
E PR-240 *2 4 ハイ GRY 4
PE *1 5 5
IV-2sq. 6 ミドリ GRN 6
保護アース 7 キ YEL 7
8 ダイ ORG 8
9 モモ PNK 9
10 ウスミドリ L-GRN 10
11 シロ/クロ WHT/BLK 11
12 シロ/アカ WHT/RED 12
注記 13 クロ BLK 13
*1)造船所手配。 14 アカ RED 14
*2)オプション。 15 ミズ L-BLU 15
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
C *3)終端のIC-307はジャンパー設定を変更する。 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
*4)SSAS仕様のとき標準構成。
DRAWN TITLE
NOTE 31/May/2012 T.YAMASAKI FELCOM 19
CHECKED 名 称
*1: SHIPYARD SUPPLY. 31/May/2012 H.MAKI インマルサットMINI-C携帯移動地球局
*2: OPTION. APPROVED
31/May/2012 Y.NISHIYAMA 相互結線図
*3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. SCALE MASS NAME
S-4

kg INMARSAT MINI-C MES


*4: STANDARD CONFIGURATION FOR SSAS. DWG.No. REF.No.
C5675-C01- D 16-023-4001-1 INTERCONNECTION DIAGRAM