Our promise to the planet is absolute. Our products are at the forefront
of low energy consumption and we continuously innovate to reduce the
environmental impact of HVACR solutions further.
We lead where others follow. We will continue our global leadership in HVACR
solutions as our specialist expertise in all market sectors combined with 90
years’ experience enable us to deliver added value in long-lasting relationships
based on trust, respect and credibility.
Table of contents
Benefits
NEW ies
W-s
er Outdoor units
UNIQ UE
autoo clea
filter fo ing
n
Indoor units conce r
a
ceiling led
units
4QFDJGJDBUJPOT
03
Over 30 years of
VRV History
›
systems
2003
Introduce VRVII-- the first R-410A
VRF system 2005
1991 Available in cooling, heat pump and Extends VRVII inverter
range with water cooled
Introduce VRV heat heat recovery
recovery › VRV-WIII
› Simultaneous cooling and 1994 refrigerant circuit › Available in heat pump and
heat recovery
heating Awarded ISO9001 certification
2009 2011 2015
Extends VRVIII range Launch total solution concept Launch of VRV IV S-series
with water cooled VRV-WIII › Integrate hot water production and › Most compact unit in the market
› Geothermal version available Biddle air curtains into VRV system › Widest range in the market
› › Connectable to Daikin Emura and
Nexura
›
›
2006-2007
Launch the extensively
re-engineered VRVIII 2010 2012-2014 2015
› Available in cooling, heat Launch of replacement VRV Setting new standards with the Launch of VRV IV i-series
pump and heat recovery (VRVIII-Q) launch of VRV IV › The invisible VRV
› Automatic charging and › Upgrade to replace older VRV units › › Unique product concept
testing › Continuous heating on heat pumps VRV IV High Ambient
› › Available in heat pump, heat
recovery, water-cooled and
replacement series
VRV IV standard &
technologies
Our new VRV IV systems set pioneering
standards in all-round climate comfort
performance. Total design simplicity, offering
rapid installation, full flexibility as well as
absolute efficiency and comfort. Find out
about all these revolutionary changes at
www.daikinmea.com
VRV IV =
3 revolutionar y standards
Variable Refrigerant Temperature
Refrigerant-cooled PCB
VRV configurator
Variable refrigerant
temperature
Customise your VRV for The colder it gets, the lower the load on the building and the lower the capacity need
in cooling mode
Capacity & Load
Thanks to its revolutionary variable refrigerant Adjust capacity by
Te control to meet
temperatue technology (VRT), VRV IV continuously the load (avoid over
capacity
System
capacity and ON/OFF
adjusts both the inverter compressor speed and the operation)
refrigerant temperature, providing the necessary
capacity to meet the building load with the highest 25 30 38 46 Outdoor temperature
seasonal efficiency at all times!
draughts)
Refrigerant temperature in
Variable Te
VRF standard
Capacity is controlled only with the variance of the 25 30 38 46 Outdoor temperature
inverter compressor
Daikin VRV IV
Variable Refrigerant Temperature control for energy
saving in partial load condition. A higher refrigerant temperature results in a higher
The capacity is controlled by the inverter compressor seasonal e ciency and higher comfort
AND variation of the evaporating (Te) and condens-
ing (Tc) temperature of the refrigerant in order to
achieve the highest seasonal efficiency.
Efficiency
E ciency up
25 30 38 46 Outdoor temperature
Variable Temp.
Fixed Temp.
How to set
the different modes?
p ate n
Set up the main operation mode
of the system
Define how the system reacts
to changing loads
ts
St St
Quick Same as above but slower response than the powerful mode.
The perfect balance: This mode would be suitable for most o ce applications
Achieves top efficiency throughout the year, Mild * and it is the factory set mode.
reacts quickly on the hottest days The perfect balance: Slower reaction speed with top e ciency
High sensible Gives customer choice for fixing coil temperature which avoids cold draughts.
(User selection) Powerful A quick reaction speed to changing load has priority, with temporarily colder
outblow as a result.
This is how most other VRF systems work and can be used for all general type of
Basic No submodes applications. Suitable for computer rooms.
Current VRF standard
Suitable for low ceiling rooms.
* Factory setting
-digit egment
display
Connect directly
to your laptop
Pre configured
settings from office
User-friendly interface
instead of push buttons
Refrigerant-cooled PCB
› Reliable cooling because it is not influenced by
ambient air temperature
› Smaller switchbox for smoother air flow
through the heat exchanger increasing
heat exchange efficiency by 5%
patents
patents
UNIQUE Target
compressor
operation
Predictive Control
Function (PCF) General VRF:
Double time against VRV IV
The large number of Daikin systems already in operation › result: quick convergence to the target temperature
Half time
and which are monitored by our Intelligent Network and reduction of waste operation of the compressor
against
software put us in the unique position of being able to general
analyse this data and develop the predictive compressor General VRF: Pi control VRF
Compressor works with feedback only for the control
control function.
› result: waste operation and longer time before reaching
target set point
DC fan motor
UNIQUE
Outer rotor DC motor for higher e ciency Conventional motor with inner rotor Daikin outer rotor
°C °C
› Avoid sandy location, i.e. near the shore and windy areas
› Clear all unwanted debris/drilling metal particles on the › In situation where the unit is installed close to coastal area
bottom tray and base leg after installation work to and exposed to strong breeze, it is important to install a
prevent any scratches or cracks onto the anti-corrosion windbreaker or retaining wall to prolong the life span of
protection coating that will cause rust formation the equipment protection coating.
Sandy Location Rooftop with Strong Sea Breeze Enclosed Area and Sea Water Splashing
Coastal sand stuck in between Strong sea breeze blowing directly to Condition
the fins causes damage to the coil can shorten the life of the coil. Sea water splashing directly to the coil causes
protection coating. solid salt forming on the fins coating.
Anti Corrosion Treatment An anti-corrosion heat exchanger cutaway view
Hydrophilic film
Special anti corrosion treatment of the heat exchanger Aluminium
provides 5 to 6 times greater resistance against acid Corrosion-resistant
rain and salt corrosion. Acrylic resin
Heat exchanger
The provision of rust proof steel sheet on the underside
of the unit gives additional protection.
Degree
of corrosion
Performed tests: 8
7
6
› VDA Wechseltest 5
4
› 3
2
› 1
› 0 Bare aluminium
1 2 3 4 5
Cycle DAIKIN P.E.
›
Degree of
corrosion
10
9
Kesternich test (SO2) 8
7
› 6
5
4
› 3
2
1
0 1 2 3 4 5 6 10 20 30 40 50 60 70
Cycle
The totalsolution
Typically, many buildings today rely on several
separate systems for heating, cooling & air curtain
As a result energy is wasted. To provide a much
more e cient alternative, VRV technology has been
developed into a total solution managing up to
of a buildings energy consumption giving large
potential to cost saving.
› Ventilation
Heating for high quality environments
Cooling › Controls
for maximum operating efficiency
Controls
Ventilation
Fresh Air
Ventilation
› Widest range in DX ventilation – AHU units
Consultants
Daikin's VRV IV technology maximises flexibility and Technical design support
leads the way in customisation to match individual Ecological design meets and
building requirements in comfort and energy, with exceeds legal requirements
reduced running costs. Maximum flexibility to meet customer requirements
Advanced software tools assist with system design
Complies with ESMA UAE regulations
Complies with MEW-Kuwait regulations
Complies with SASO Saudi regulations
Building owners
VRV IV is the ultimate in customised comfort and Up to 40% energy consumption saving over conventional AC System
intelligent control tailored to your individual needs Single point of contact for the design and
and to maximise energy efficiency. Annual cost maintenance of your climate system
savings up to % (compared to VRV III). Integrated system, combining air conditioning,
ventilation, etc. allows maximum energy efficiency
Multiple systems can be managed in exactly
the same way for the key accounts
Dedicated after-sales service to
ensure fast on-site support
Installers
Daikin VRV IV sets the standard with state-of-the-art
technology and time-saving commissioning and Simplified and time-saving commissioning
servicing. with VRV configurator
Wide range of outdoor units (up to 48HP)
One supplier = one point of contact
Maximum flexibility to meet customer requirements
Customised training to maximise expertise
Out door units can be single units or combined in multiple units as a module
for larger capacity applications
Outdoor units
39:525
›
›
VRVIV-S
Covers all thermal needs of a building via a single point of contact: accurate 39:425:
series
38&:25
+
39:525
+]
39:425:
+]
38&:25
+
+]
+]
Indoor units
varying lengths
ESP ›
FXSQ-A
Wall FXAQ-PVER1
› Flat, stylish front panel is more easy to clean
mounted › Small capacity unit developted for small of well-insulated rooms
unit › Reduced energy consumption thanks to DC fan motor
› FXAQ-PVE
discharge angles
Ceiling
› ect
suspended ›
Ceiling suspended
/hr )
Ventilation
VAM-FC Heat recovery
Ventilation
VKM-GB Heat recovery
(50Hz only) Air processing
Heat reclaim
ventilation
Ventilation
VKM-GBM Heat recovery
(50Hz only) Air processing
FXMQ-MFV1 Ventilation
(50Hz only) Air processing
Ventilation
Heat recovery
Air handling DX total fresh
Air processing
units air package
Filtration
Air handling unit applications
VRV IV
condensing unit
(single or multi)
gas
liquid
Capacity:
Up to 269 kW (Nominal Capacity) - by 4x24 HP OU. Expansion Value Sizes: 50 - 63 - 80 - 100 - 125 - 140 - 200 - 250 - 400 -500
Control w: Off the shelf control of air temperature (discharge Control y: Control of refrigerant (Te/Tc) temperature via Daikin
temperature, suction temperature, room temperature) via any control (no DDC controller needed) with 3rd party thermostat
DDC controller using a proportional 0~10V algorithm for capacity (Daikin control for field settings and error indication)
control Control z: Control of air temperature (suction temperature, room
Control x: Precize control of air temperature (discharge temperature) via Daikin control (no DDC controller needed)
temperature, suction temperature, room temperature) requiring a
preprogrammed DDC controller (for special applications) using a
proportional 0~10V algorithm for capacity control
Ts Ts
Te Td Te Td
Daikin AHU Daikin AHU
control box: control box:
DDC EKEQFCBA DDC
Tr Room EKEQFCBA Tr Room
ON / OFF
KRP4A51
Daikin Ts AHU
Ts Te Td
control box: Te Td
EKEQFCBA Daikin AHU
Tr Room control box:
EKEQDCB Room
Tr
BRC1D52 EKEQMCB
BRC1E53A BRC1D52
BRC1E53A
24
INTELLIGENT
TOUCH MANAGER
DCM601A51
INFRARED REMOTE
CONTROLLER
25
BRC4*/BRC7*
Infrared remote control
Operation buttons: ON / OFF, timer mode start / stop, timer
mode on
BRC1D52
NEW BRC1E53A
Italian, Portugese
Romanian, Slovenian,
Bulgarian
Slovak, Albanian
26
BRC2E52A / BRC3E52A
Window contact
(field supply)
Without operation mode selector
DCS302C51
›
units) can be controlled
›
separate locations
› zone control
› group control
› malfunction code display
›
› air flow direction and air flow rate of HRV can be controlled
› expanded timer function
DST301B51
Schedule timer
Enabling 64 groups to be programmed.
›
›
›
›
DCS301B51
›
›
› operating status indication (normal operation, alarm)
› centralised control indication
›
DTA113B51
› Rotation function
› Backup operation function.
DCS601C51
Detailed & easy monitoring and operation of VRV systems (max. 64 indoor units groups).
Network
third party controller (domotics, BMS, etc.) via http interface Fire alarm
Ethernet
Forced OFF contact input
DIII-NET
Control Systems
› VRV
System layout › Flexible grouping in zones Cost performance › HRV
› › Yearly schedule › Free cooling function › Sky Air
controlled › Fire emergency stop control › Labour saving › Split (via interface adapter)
› Touch panel (full colour LCD › Interlocking control › Easy installation
via icon display) › Increased HRV monitoring › Compact design: limited
and control function installation space
› Automatic cooling / heating › Overall energy saving
change-over
› Heating optimization
› Temperature limit
›
(general, administration
& service)
› Quick selection and full
control
› Simple navigation
Centralised control systems NEW
Flexible
›
equipment such as kWh meters, emergency
input, window contact, … Easy follow up of energy consumption
› Modular concept allows your cloud to grow
with your business
›
Pulse input
Digital input
Functions overview
Indoor uit
Local solution Cloud solution
Languages EN, DE, FR, NL, ES, IT, EL, PT,
Depends on local device RU, TR, DA, SV, NO, FI, CS,
HR, HU, PL, RO, SL, BG, SK
Control Systems
For available Daikin Cloud Service options refer to the option list
NEW Mini Building Management System Check on
https://www.youtube.com/
DaikinEurope
DCM601A51
Mini BMS
Price competitive mini BMS
Cross-pillar integration of Daikin products
Integration of third party equipment
Web Access
Internet
Extranet
LAN
3G
Max. 7
DCM601A51 ITM plus adaptor line adapters
Di/Pi port
kWh meter
Direct plug & play connection!
Split
BACnet WAGO
Chillers and AHU
Fan coil units
Lighting Fan
I/O module
Pump Sensor
Mini Building Management System NEW
User friendliness
Flexibility
Plug & play
NEW › Cross-pillar integration (heating, air conditioning,
applied systems, refrigeration, air handling units)
NEW ›
› I/O for integration of equipment such as lights,
pumps… on WAGO modules
› Modular concept for small to large applications
Split Fan coils Chillers and AHU Refrigeration
›
and combine multiple ITM via the web interface
Functions overview
CLOUD
Intelligent Network
performance monitoring 24/7
and analysis
Data server
Performance supervision
Internet
and analysis
24/7
Prediction analysis
Data trend logging
Information to:
› customers
› service company
CLOUD Controller
Performance monitoring
Analysis
Daikin’s unique Intelligent Network Service
aims to prevent the equipment coming to an Be connected with Daikin’s experts, this gives you
unexpected stop or needing emergency repair. a clear overview of operability and use of the air
conditioning system.
› Daikin continuously monitors energy, operation
Fast response, better prepared and comfort data. Thanks to periodic analysis of
the data, Daikin can suggest ways of improving
› If an alarm does occur, the service provider is performance.
immediately alerted and receives all crucial › if there is a problem, Daikin specialists will analyse
information. the operation data history to provide remote
› Early fault indication (predictions) : operation data support.
are 24/7 checked by Intelligent Network prediction
algorithms to act as early as possible, averting
unscheduled breakdowns.
RXYTQ-T7YF
(1) indoor temperature: 26,7°CD B, 19,4°CWB, outdoor temperature: 35°CDB, AHRI 1230:2010, power input indoor units (duct type) included. As per AHRI/ SASO
(2) Outdoor energy efficiency rating and power input based on Eurovent testing and listing of the 50Hz models only. As per Estidama
(3) indoor temperature: 29,0°CDB, 19,0°CWB, outdoor temperature: 46°CDB, ISO15042:2011, power input indoor units (duct type) included. As per ESMA
(4) indoor temperature: 26,6°CDB, 19,4°CWB, outdoor temperature: 48°CDB, AHRI 1230:2010, power input indoor units (duct type) included. As per MEW
(5) Heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, Eurovent 2015, equivalent
refrigerant piping: 5m, level difference: 0m.
(6) Independently tested by 3rd party laboratory (Intertek- USA)
RXYSQ-TMY1B
RXYSQ_TMY1
Capacity Ton 8 10 12
(1) Indoor temperature: 26.7 ºCDB, 19.4 ºCWB, Outdoor temperature: 35 ºCDB, AHRI (4) Indoor temperature: 26.6 ºCDB, 19.4 ºCWB, outdoor temperature: 48 °CDB,
1230:2010, power input indoor units (duct type) included. As per AHRI/ SASO AHRI 1230:2010, power input indoor units (duct type) included. As per MEW
(2)
(5) Heating capacities are based on indoor temperature: 20 ºCDB, outdoor
and listing of the 50Hz models only. As per Estidama. temperature: 7 ºCDB, 6 ºCWB, Eurovent 2015, equivalent
(3) Indoor temperature: 29 ºCDB, 19 ºCWB, outdoor temperature: 46°CDB,
ISO15042:2011, power input indoor units (duct type) included. As per ESMA.
37
RWEYQ-T9
Covers all thermal needs of a building via a single point of contact: Level difference between the VRV-W and indoor units:
50m if the VRV-W is above
accurate temperature control, ventilation, air handling units, 40m if the VRV-W is below
Biddle air curtains and hot water Level difference between indoor units: 30m NEW
VRV-W
Outdoor system RWEYQ 16T9 18T9 20T9 22T9 24T9 26T9 28T9
System Outdoor unit module 1 RWEYQ8T9 RWEYQ8T9 RWEYQ8T9 RWEYQ10T9 RWEYQ12T9 RWEYQ12T9 RWEYQ14T9
Outdoor unit module 2 RWEYQ8T9 RWEYQ10T9 RWEYQ12T9 RWEYQ12T9 RWEYQ12T9 RWEYQ14T9 RWEYQ14T9
Capacity range HP 16 18 20 22 24 26 28
Cooling capacity 35°CDB kW 44.8 50.4 55.9 61.5 67 73.5 80
EER at nom. Capacity 35°CDB kW 6.4 6.08 5.98 5.65 5.55 5.30 5.04
Heating capacity 6°CWB kW 50 56.5 62.5 69 75 82.5 90
COP at nom. Capacity 6°CWB kW 6.5 6.45 6.3 6.25 6.1 5.735 5.37
Outdoor system RWEYQ 30T9 32T9 34T9 36T9 38T9 40T9 42T9
System Outdoor unit module 1 RWEYQ8T9 RWEYQ8T9 RWEYQ8T9 RWEYQ12T9 RWEYQ12T9 RWEYQ12T9 RWEYQ14T9
Outdoor unit module 2 RWEYQ10T9 RWEYQ12T9 RWEYQ12T9 RWEYQ12T9 RWEYQ12T9 RWEYQ14T9 RWEYQ14T9
Outdoor unit module 3 RWEYQ12T9 RWEYQ12T9 RWEYQ14T9 RWEYQ12T9 RWEYQ14T9 RWEYQ14T9 RWEYQ14T9
Capacity range HP 30 32 34 36 38 40 42
Cooling capacity 35°CDB kW 83.9 89.4 95.9 100.5 107 113.5 120
EER at nom. Capacity 35°CDB kW 5.9 5.83 5.66 5.55 5.38 5.21 5.04
Heating capacity 6°CWB kW 94 100 107.5 112.5 120 127.5 135
COP at nom. Capacity 6°CWB kW 6.33 6.23 5.99 6.1 5.85 5.61 5.37
RWEYQ-PYL
Standard operation
OUTSIDE UNITS
Heat Pump/Heat Recovery
Notes: 1. 6SHFLÀFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV 2. 1. In the case of heat pump system, suction gas pipe is not used.
&RROLQJ
,QGRRUWHPS$CDB, 19.5$&:%LQOHWZDWHUWHPS$C 2. In the case of heat recovery system.
,QGRRUWHPS$CDB, 19.0$&:%LQOHWZDWHUWHPS$C 3. In the case of heat pump system.
+HDWLQJ,QGRRUWHPS$&'%LQOHWZDWHUWHPS$C 3. 7KLVXQLWFDQQRWEHLQVWDOOHGLQWKHRXWGRRUV,QVWDOOLQGRRUV0DFKLQHURRPHWF
(TXLYDOHQWSLSLQJOHQJWKP 4. $PELHQWWHPSHUDWXUHDW²$&+HDWUHMHFWLRQIURPWKHFDVLQJN:+3
/HYHOGLIIHUHQFHP 5. &RQQHFWDEOHWRFORVHGW\SHFRROLQJWRZHURQO\
3OHDVHEHVXUHWRUHIHUWRWKH(QJLQHHULQJ'DWDIRUIDFLOLW\Gesign.
39