You are on page 1of 41

IP-20N/G Overview

May 2015
Version 5
Agenda
• IP-20N Product Family
• IP-20G Overview
• IP-20N Overview
• 1U and 2U chassis

• TCC – Traffic Control Card

• RMC – Radio Modem Card

• ELIC – Ethernet Line Interface Card

• TDM Line cards

• IVM – Inventory Module

• PDC – Power Distribution Card

• Fan Module and Air Filter

2 Proprietary and Confidential


FibeAir IP-20 Product Family
Ethernet + TDM Ethernet
IP-20S IP-20E
Single Direction
Single Carrier

IP-10G IP-20G

Compact Compact
High End Edge Node All-Outdoor E-Band
Node Node

IP-20C
Two Directions

IP-20G
Two Carriers

Multi-Technology Edge Node Compact All-Outdoor


Multi-Core Node

IP-20G IP-20N IP-20LH IP-20C HP


Multi Direction
Multi Carrier

Multi-Technology Compact High Power


Cascaded Edge Node Multi-Technology Aggregation Node Multi-Carrier Trunk Node Multi-Carrier Trunk

Integrated Carrier Ethernet Node

3 Proprietary and Confidential


IP-20G Overview

4
IP-20G: Font panel

• 1RU for up to 2 Radios


• Support all radio RFU-C, 1500HP/RFU-HP
• Configuration: 1+0, 1+1HSB/SD, 2+0, E-W

1RU

External Power
16 x E1s 1 or 2 RFU
Alarms 2 x FE -48V DC
(optional) 2 x GE interfaces
(DB9) Management (Single-feed &
Optical (TNC) Dual-feed options)
(RJ45) 2 x Dual-Mode: (SFP)
Sync in/out GE Electrical or
(RJ45) ‘Cascading’
Terminal (RJ45) 2 x GE
(RJ45) Electrical
(RJ45)

5 Proprietary and Confidential


IP-20G: dual FE Management port in single RJ45 interface

6 Proprietary and Confidential


7 Proprietary and Confidential
IP-20N Overview

8
FibeAir IP-20N Product Overview
Purpose built for Nodal deployments
Unified architecture with common cards
• Traffic/Control cards (TCC)
• Radio interface cards (RMC)
o Non-XPIC
o XPIC
o 2048 QAM
1RU chassis, Up to 5 RFUs • Line cards (LIC)
o Eth – 4 x 1GE
o TDM – 16 x E1/DS1 LIC
– 1 x STM-1/OC3 LIC
- 1 x ch STM-1
o LIC-X-E4-Elec./Opt
• Radio interface cards (RMC)
o Non-XPIC
o XPIC
o 2048 QAM
2RU chassis, Up to 10 RFUs
Full redundancy option (No SPoF) Configuration: N+0/N+1 (N up to 10), 1+1/2+2, combination
of XPIC/non-XPIC, SD/non-SD

Ultra-high flexibility/modularity
Optimized foot-print, density, scalability & availability

9 Proprietary and Confidential


IP-20N – 2RU Chassis
Filter tray 2 x Slots for Fans tray
(optional) power distribution
cards (PDC)

11 12
7 8 9 10
3 4 5 6
1 2

2 x Slots for 10 x Universal slots for:


Main traffic and - Radio interface cards (RMC)
control cards (TCC) - Ethernet line cards (4 x GE)
- TDM line cards

10 Proprietary and Confidential


Slots Numbering

3 4 5 6
1 2 51

Slots Numbering starts from bottom left

11 12 50
7 8 9 10
3 4 5 6
1 2 51
11 Proprietary and Confidential
Recommendations
It is recommended to place the same type of cards in adjacent pairs, as follows:

• Slots 3 and 4
• Slots 5 and 6
• Slots 7 and 8 (2RU only)
• Slots 9 and 10 (2RU only)

The reason for this is that for certain features, connectivity is supported in the backplane
between these slot pairs

For example 2+2 HSB SD configuration with XPIC:

• 1+1 or 2+2 are supported in release 7.9


• When combining HSB SD and XPIC, the HSB SD protection group and the
XPIC group cannot be identical. A valid combination would be:

XPIC Group #1: Slot 3 and 4


XPIC Group #2: Slot 5 and 6
Radio Protection Group #1: Slot 3 and 5
Radio Protection Group #2: Slot 4 and 6

12 Proprietary and Confidential


Traffic – Ethernet Matrix
TCC Slot 11 Slot 12

Slot 7 Slot 8 Slot 9 Slot 10

Slot 3 Slot 4 Slot 5 Slot 6

SGMII to TCC primary


TCC Slot 1 Slot 2 SGMII to TCC backup

13 Proprietary and Confidential


TCC – Traffic control card

14
11
Traffic Control Card (TCC)
1

• Main functions:
• TCC-B and TCC-B2 – doesn’t support Multi-Carrier ABC
• TCC-B-MC – required for Multi-Carrier ABC configurations, HSB BBS SD support
• 1x Up to 8+0 MC-ABC (Up to 2.5 Gbps)
• 1+1/2+2 MC-ABC/HSB (Up to 1Gbps)
• Mixed Nx1+0/1+1 & 1x ABC (4+0)
• Network processor with 16 ports
• 10 Gbps switching capacity
• 6,25 Mpps (Mega packet per second) switching capacity
• Shelf control and management
• Ethernet traffic management and switching
• Clock unit

Ceragon SD cards with Cera OS:

Industrial SD card 1GB class 6

15 Proprietary and Confidential


12
7 8 9 10
3 4 5 6
2

MNG port 1

MNG port 2
CPU
1Gb SGMII / (2.5Gb) Radio Card

Ethernet Switch
16 ports – 10Gbps

Line Interface 1Gb SGMII / (2.5Gb)

1Gb SGMII / (2.5Gb)


Line Interface 1Gb SGMII / (2.5Gb)

1Gb SGMII / (2.5Gb)


Ethernet Card
1Gb SGMII / (2.5Gb)

1Gb SGMII / (2.5Gb)

16 Proprietary and Confidential


11
TCC Indicators & Connectors
1
1

Activity
LED
SYNC Serial Gigabit
Port Port Electrical Ports

Handle External Management Gigabit Optical Handle


Alarms Ports Ports
Port

17 Proprietary and Confidential


RMC – Radio Modem Card

18
12
Radio Modem Cards (RMC-B) 7
3
8
4
9
5
10
6
2

• Based on Ceragon’s new SoC modem


• Supports up to 2048 QAM
• Supports XPIC and non XPIC (same Hardware)
• Supports Header De-Duplication

RMC B
XPIC Yes
Multi-Carrier ABC Yes
Modem type Mars modem
Modulation 2048 QAM with Premium RFU + ACM
FD and SD Yes
IP20N communication with
Yes
IP20G across a link

19 Proprietary and Confidential


12
RMC Indicators & Connectors 7
3
8
4
9
5
10
6
2

IF Connector

Handle Handle

ACT LINK RFU


LED LED LED

Color ACT LINK RFU


off No power No power No power

green OK, active mode Link OK no alarms RFU is OK


Minor or warning Minor or warning
yellow OK, standby mode
alarm alarm
Critical or major Critical or major
red failure
alarm alarm

20 Proprietary and Confidential


ELIC – Ethernet Line Interface Cards

21
Ethernet Line Interface Card 12

Electrical LIC-XE4-Elec 2

• LIC-XE4-Elec
• Supports 4 GBE ports (one combo)
• Works only on slots 2 and 12
• MDI/MDIX support
• Cascading ports (port 3 & 4)

22 Proprietary and Confidential


LIC-XE4-Elec 12

Indicators & Connectors 2

Gigabit Electrical Ports

Handle Handle

ACT SFP SFP


LED Slot LED

Color ACT Left LED for port Right LED for port SFP LED
Interface is disabled
Cable not connected,
or the interface
off No power Interface is disabled link not ok, interface
operates at
is disabled
100BaseT mode
Interface operates at
the interface is Interface is enabled
1000BaseT mode,
enabled and link is and link is OK,
green OK, no alarms Blinking means
OK (Blinking = traffic blinking means traffic
operates at 10BaseT
activity) activity
mode
Card failure or
red --------------------------- --------------------------- ----------------------------
hardware failure

23 Proprietary and Confidential


Ethernet Line Interface Card 12

Optical LIC-XE4-Opt 2

• LIC-XE4-Opt
• Supports 4 GBE ports (firs port is combo)
• Total 4x SFP
• Works only on slots 2 and 12
• Cascading ports (port 3 & 4)

24 Proprietary and Confidential


LIC-XE4-Opt 12

Indicators & Connectors 2

Gigabit Optical Ports

Handle Handle

ACT Gigabit SFP


LED Electrical port LED

Color ACT Left LED for port Right LED for port SFP LED
Interface is disabled
Cable not connected,
or the interface
off No power Interface is disabled link not ok, interface
operates at
is disabled
100BaseT mode
Interface operates at
the interface is Interface is enabled
1000BaseT mode,
enabled and link is and link is OK,
green OK, no alarms Blinking means
OK (Blinking = traffic blinking means traffic
operates at 10BaseT
activity) activity
mode
Card failure or
red --------------------------- --------------------------- ----------------------------
hardware failure

25 Proprietary and Confidential


TDM Line cards

26
LIC-T16 (16xE1/DS1) 12
7 8 9 10
Line Interface Card 3 4 5
2
6

• TDM-LIC
• 16 E1/T1s
• 1588 client clock and boundary clock as a future option

27 Proprietary and Confidential


LIC-T16 (16xE1)- Indicators & Connectors 7 8 9
12
10
3 4 5 6
2

16 x E1/ DS1 Connector

Handle Handle

SYNC Connector ACT LED E1/DS1LED


Color ACT Sync Left LED for Sync Right LED for E1/DS1 LED
port port
The interface is
The interface is The interface is
off No power disabled or no signal is
disabled disabled
being received
Indicates whether a valid Indicates whether the
green OK, no alarms signal is being received interface is configured to No alarms
when enabled export a clock

Card failure or
red --------------------------- --------------------------- Any alarms
hardware failure

Optionally is available LIC-T16 without SYNC port

28 Proprietary and Confidential


TDM LIC-T155 (1x ch-STM-1) 7
3
8
4
9
5
12
10
6
2

• TDM-LIC
• 1 STM-1/OC3
• 1588 client clock and boundary clock as a future option
• The 1 x ch-STM-1 interface uses an optical SFP connector.

29 Proprietary and Confidential


TDM LIC-T155 (1x ch-STM-1) 12
7 8 9 10
Indicators & Connectors 3 4 5
2
6

STM-1/OC3 SFP

Handle Handle

ACT SYNC STM-1/OC3


LED Connector LED

Color ACT Sync Left LED for Sync Right LED for STM1/OC3
port port
The interface is
The interface is The interface is
off No power disabled or no signal is
disabled disabled
being received
Indicates whether a valid Indicates whether the
green OK, no alarms signal is being received interface is configured to No alarms
when enabled export a clock

Card failure or
red --------------------------- --------------------------- Any alarms
hardware failure

30 Proprietary and Confidential


TDM LIC-STM-1/OC3-RST 7
3
8
4
9
5
12
10
6
2

31 Proprietary and Confidential


Inventory Module (IVM)

32
Mandatory Cards - IVM
• Single card for 1RU and 2RU chassis.
• 2 x E2PROM on single board (function as 2 separated cards).
• Installed at the back of the chassis
• Holds the chassis:
• License.
• Node MAC address (48 MACs per unit).
• Serial number.

33 Proprietary and Confidential


PDC – Power Distribution Card

34
Mandatory Cards – PDC
Power Distribution Card
• Monitors the inputs signal
• Drives the -48V signal
• Converts the -48V signal to other power levels
• Different card for 1RU chassis and 2RU chassis
• 2U chassis uses two PDC card for redundancy
• 1U chassis uses dual input for redundancy

35 Proprietary and Confidential


Power Distribution Card
• A 2RU IP-20N can use two PDC cards for redundancy. Each PDC provides 48V
power to all modules in the chassis via the backplane, on different lines.
• A diode bridge in the modules prevents power spikes and unstable power from the
two power sources.
• Voltage range: -40,5 VDC to -60 VDC
• The maximum rating of the overcurrent protection shall be 3 Amp per link, while the
maximum current rating is 9A for 1RU and 17Amp for 2RU
• The power source must be grounded
• If the voltage goes below -38V, the LED displays Red. When the voltage returns to -
40V or higher, the Red indication goes off and the Green indication reappears.

Standard PDC Interface Dual - Input PDC Interfaces

36 Proprietary and Confidential


Power consumption specification

37 Proprietary and Confidential


Fans Module & Air Filter

38
Mandatory Cards – Fans
• Four fans inside the fans module
• Powered up from -48VDC from the backplane
• Different module for 1RU and 2RU chassis

39 Proprietary and Confidential


Filter Tray - optional

• IP-20N offers a filter as optional


equipment. If a filter tray is not
ordered, the IP-20N chassis is
delivered with a blank filter slot
cover.

40 Proprietary and Confidential


Thank You

You might also like