Derate table

2806A-E18 TAG1A,
2800
Series
TAG2, TAG3
Diesel Engines

2806A-E18 TAG1A @ 1500 rev/min


Derate for high intake temperature and/or elevated altitude from ISO 3046 standard conditions.

Derate Chart 2806-E18 660 kVA Low BSFC

35%

30%

25%

20%
Dearate (%)

15%

10%

5%

0%
0 500 1000 1500 2000 2500 3000 3500 4000 4500

Altitude (MASL)

Total Derate 25°C Total Derate 30°C Total Derate 37°C Total Derate 43°C Total Derate 50°C

Note: Ambient temperature at air cleaner inlet.

1 of 4
Publication No. TPD1706E, Issue 3, October 2019.
Copyright © 2019 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
2806A-E18 TAG2 @ 1500 rev/min
Derate for high intake temperature and/or elevated altitude from ISO 3046 standard conditions.

Derate Chart 2806-E18 700 kVA Low BSFC

40%

35%

30%

25%
Dearate (%)

20%

15%

10%

5%

0%
0 500 1000 1500 2000 2500 3000 3500 4000 4500

Altitude (MASL)
Total Derate 25°C Total Derate 30°C Total Derate 37°C Total Derate 43°C Total Derate 50°C

Note: Ambient temperature at air cleaner inlet.

2 of 4
Publication No. TPD1706E, Issue 3, October 2019.
Copyright © 2019 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
2806A-E18TAG1A & TAG2 @ 1800 rev/min
Derate for high intake temperature and/or elevated altitude from ISO 3046 standard conditions.

Derate Chart 2806-E18 550 ekW Low BSFC

45%

40%

35%

30%

25%
Dearate (%)

20%

15%

10%

5%

0%
0 500 1000 1500 2000 2500 3000 3500 4000 4500

Altitude (MASL)

Total Derate 25°C Total Derate 30°C Total Derate 37°C Total Derate 43°C Total Derate 50°C

Note: Ambient temperature at air cleaner inlet.

3 of 4
Publication No. TPD1706E, Issue 3, October 2019.
Copyright © 2019 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
2806A-E18 TAG3 @ 1800 rev/min
Derate for high intake temperature and/or elevated altitude from ISO 3046 standard conditions.

Derate Chart 2806-E18 600 ekW Low BSFC

35%

30%

25%

20%
Dearate (%)

15%

10%

5%

0%
0 500 1000 1500 2000 2500 3000 3500 4000 4500

Altitude (MASL)

Total Derate 25°C Total Derate 30°C Total Derate 37°C Total Derate 43°C Total Derate 50°C

Note: Ambient temperature at air cleaner inlet.

4 of 4
Publication No. TPD1706E, Issue 3, October 2019.
Copyright © 2019 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com