Assignment one : Applying Experiments Full-wave Rectifier using Proteus, DEADLINE

Wednesday ,22/07/2020
__________________________________________________________________________
Q: _ Full wave rectifier with R & RL-load using Diode (Experiment 2)

APPARATUS:
1. Low-voltage AC power supply
2. One 1N4001 diode
3. Resistance 27.5Ω
4. Oscilloscope

Note: _
The diode need not be an exact model 1N4001. Any of the "1N400X" series of rectifying diodes
are suitable for the task

PROCEDURE:
1. Connect CH1 of oscilloscope to Input and CH2 to Output/Load R and RL of a circuit.

2. Switch on the oscilloscope and the sinusoidal supply.

3. Sketch the input waveform

4. Measure and record time T , peak voltage Vp and peak to peak voltage Vpp of Input supply

5. T= _____2mS__________ Vp: _________110v____ Vpp ________220v_______


6.Sketch the waveform and label it to show the periods when the diode is conducting and those
when it is not. Time T depends upon the frequency of your power supply.

Output wave with R LOAD

Measure and record time T and peak voltage Vp of output

T= __________2mS_____ Vp: _______107V________


Output wave with R LOAD

T= __________2mS_____ Vp: _______109V

DESGIN OF Circuit
Confirm this Vp should be very nearly equal to the peak voltage of the alternating supply.