Motor structure
Nameplate 3
3.6.4 Type designation
DRN132M4/BE11/HR/FI/TF
DR Series
N Type designation
132 Size
M Length
4 Number of poles
/BE11 Brake
/HR Manual brake release
FI Output option
TF Thermal motor protection
Designation
DRS.. Standard motor, Standard efficiency IE1
DRE.. Energy-efficient motor, High Efficiency IE2
DRP.. Energy-efficient motor, Premium Efficiency IE3
DRN.. Energy-efficient motor, Premium Efficiency IE3
DRL.. Asynchronous servomotor
DRK.. Single-phase operation with running capacitor
DRM.. Torque motor: AC motor for operation at speed n = 0
DR..J Line start permanent magnet motor
71 – 315 Sizes:
71 / 80 / 90 / 100 / 112 / 132 / 160 / 180 / 200 / 225 / 315
K, S, M, L, Lengths
MC, LC,
ME, H, LS
2, 4, 6, 8/2, 8/4, 4/2, 12 Number of poles
21927189/EN – 07/2015
Designation Option
/FI IEC foot-mounted motor
/F.A, /F.B Universal foot-mounted motor
/FG 7-series integral motor, as stand-alone motor
/FF IEC flange-mounted motor with bore holes
/FT IEC flange-mounted motor with threads
/FL General flange-mounted motor (other than IEC)
/FM 7-series integral motor with IEC feet
/FE IEC flange-mounted motor with bore and IEC feet
/FY IEC flange-mounted motor with threads and IEC feet
/FK General flange-mounted motor (deviating from IEC) with feet
/FC C-face flange-mounted motor, dimensions in inch
Designation Option
/BE.. Spring-loaded brake with specification of size
/HR Manual brake release of the brake, automatic re-engaging
function
/HF Manual brake release, lockable
/RS Backstop
/MSW MOVI‑SWITCH®
/MM03 – MM40 MOVIMOT®
/MO MOVIMOT® option(s)
/MI Motor identification module for MOVIMOT®
Designation Option
/TF Temperature sensor (PTC thermistor or PTC resistor)
/TH Thermostat (bimetallic switch)
/KY 1 KTY84 – 130 sensor
/PT 1 / 3 PT100 sensor(s)
21927189/EN – 07/2015
Designation Option
/ES7S /EG7S Add-on speed sensor with Sin/Cos interface
/EH7S /EV7S
/ES7R /EG7R Add-on speed sensor with TTL (RS-422) interface,
/EH7R V = 9 – 26 V
/EI7C /EI76 /EI72 Built-in incremental encoder with HTL interface and
/EI71 6 / 2 / 1 period(s)
/EI7C FS.. Safety-rated incremental encoder (marked with FS logo on the
motor nameplate)
For information, refer to the addendum to the operating instruc-
tions "Safety-Rated Encoders – DR..71 – 315, DRN80 315 AC
Motors – Functional Safety"
/AS7W /AG7W Add-on absolute encoder, RS-485 interface (multi-turn)
/AS7Y /AG7Y / Add-on absolute encoder, SSI interface (multi-turn)
AH7Y
/ES7A /EG7A Mounting adapter for speed sensors
/EV2T /EV2R Add-on incremental encoder with solid shaft
/EV2S /EV2C
/XV.A Mounting adapter for non-SEW speed sensors
/XV.. Mounted non-SEW speed sensor
/XH.. Mounting adapter for non-SEW hollow-shaft encoders
Designation Option
/IS Integrated plug connector
/ASE. HAN 10ES plug connector on terminal box with single locking
latch (cage clamp contacts on the motor side)
/ASB. HAN 10ES plug connector on terminal box with double locking
latch (cage clamp contacts on the motor side)
/ACE. HAN 10E plug connector on terminal box with single locking
latch (crimp contacts on the motor side)
/ACB. HAN 10E plug connector on terminal box with double locking
latch (crimp contacts on the motor side)
/AME. /ABE. HAN Modular 10B plug connector on terminal box with single
/ADE. /AKE. locking latch (crimp contacts on the motor side)
/AMB. /ABB. HAN Modular 10B plug connector on terminal box with double
/ADB. /AKB. locking latch (crimp contacts on the motor side)
21927189/EN – 07/2015
3.7.6 Ventilation
Designation Option
/V Forced cooling fan
/VH Radial fan on fan guard
/Z Additional inertia (flywheel fan)
/AL Metal fan
/U Non-ventilated (without fan)
/OL Non-ventilated (closed B-side)
/C Protection canopy for fan guard
/LF Air filter
/LN Low noise fan guard
3.7.7 Bearing
Designation Option
/NS Lubrication device
/ERF Reinforced bearings on A-side with roller bearing
/NIB Insulated bearing B-side
Designation Option
/DUB Diagnostic unit brake = brake monitoring
/DUE Diagnostic Unit Eddy Current = Function and wear monitoring
of the brake
Designation Option
/DH Condensation drain hole
/RI Reinforced winding insulation
/RI2 Reinforced winding insulation with increased resistance
against partial discharge
/2W Second shaft end on the motor/brakemotor
21927189/EN – 07/2015
INFORMATION
You find more information in the "AC Motors" catalog.
PN Rated power
MN Rated torque
nN Rated speed
IN Rated current
cosφ Power factor
η50% Efficiency at 50% of the rated power
η75% Efficiency at 75% of the rated power
η100% Efficiency at 100% of the rated power
IA/IN Starting current ratio
MA/MN Starting torque ratio
MH/MN Ramp-up torque ratio
MK/MN Breakdown torque ratio
mMot Mass of the motor
JMot Mass moment of inertia of the motor
BE.. Brake used
Z0 BG Switching frequency for operation with BG brake controller
Z0 BGE Switching frequency for operation with BGE brake controller
MB Braking torque
mBMot Mass of the brakemotor
JBMot Mass moment of inertia of the brakemotor 24832936/EN – 09/2018
DRN315S4 110 710 1488 870 23400 BE122 1600 1000 24400
53
-
DRN315M4 132 850 1487 890 24800 BE122 2000 1020 25800
46
-
DRN315L4 160 1030 1486 1020 28600 BE122 2000 1150 29600
34
-
DRN315H4 200 1280 1489 1130 35200 BE122 2000 1270 36200
23
( ) 90S(R) 90L
LS 425 457
LBS (B5/B14) 375 407
LBS (B3) 373 405