Design warning Solutions Max. element permeate flow exceeded 3, 5, 7, 11 The concentrate flow less than minimum 1, 5, 4 together with 6 2 unless the feed flow is The feed flow greater than maximum fixed, 3 Maximum feed pressure exceeded 1, 3, 8 Temperature is above acceptable value 10 Max. element recovery exceeded: • If the problem is encountered in front elements 1, 5, 6, 11 • If the problem is encountered in rear elements 1, 5, 6 Solutions Guide Decrease system recovery 1 Increase the number of Reduce Temp (recommend 6 elements per PV (keeping the 10 customer to reduce temp during Increase system recovery 2 same APF*) pretreatment).
Reduce average system flux (add
Decrease the number of 3 membranes, PV) 7 Combine two element types: elements per PV (keeping the same APF*) 11 lower energy elements in rear positions (ISD configuration) Reduce number of PV 4 (increasing average system flux) Install lower energy Enable a recirculation loop 8 membranes or ISD with lower *APF – Average Permeate Flux 5 Pass 1 Conc to Pass 1 Feed energy membranes (normally not used for SW appl.) Warnings and typical solutions – For multistage systems Design warning Solutions Max. element permeate flow exceeded 3, (5), 6, 10, 13 1, 4, (5), 6, 7, (10 and The concentrate flow less than minimum 11 only for the 1st stage) The feed flow greater than maximum in any of the stages 2, 3 Maximum feed pressure exceeded 1, 3, 9 Temperature is above acceptable value 12
Max. element recovery exceeded:
• If the problem is encountered in front elements (front stage/s) 1, (5), 6, 7, 10, 13 • If the problem is encountered in rear elements (rear stage/s) 1, (5), 7 Solutions Guide Decrease system recovery 1 Add backpressure in first and/or 10 Add booster pump in first or second stage 6 second stages permeate streams concentrate 2 Increase system recovery Use a lower active area membrane Increase number of PV 7 Increase the number of elements 11 element (keeping the same APF) 3 (reducing average system flux) per PV (keeping the same APF) Reduce Temp (recommend customer Reduce number of PV 8 Decrease the number of elements 12 4 (increasing average system flux) per PV (keeping the same APF) to reduce temp during pretreatment).
Combine two element types: lower
Install lower energy membranes or Enable a recirculation loop: Pass 1 Conc to Pass 1 Feed 9 ISD with lower energy membranes 13 energy elements in second or third 5 (normally not used for SW appl.) stages *APF – Average Permeate Flux