Professional Documents
Culture Documents
Hotel Study PDF
Hotel Study PDF
HOTELS
ARCHITECTURAL DESIGN
SUBMITTED BY :
GROUP 3
B.ARCH , VI SEMESTER
S.NO PUBLIC AREAS PRIVATE PRIVATE SEMI PRIVATE
AREAS(STAFF) AREAS(GUEST)
1 LOBBY + RECEPTION ADMINISTRATION OFFICE SINGLE BEDROOM BANQUET
10 PANTRY
GRADE B CITIES:
1. ONE MULTI-CUISINE RESTAURANT OPEN FROM 7 A.M. TO 11 P.M..
2. ONE 24 HR. ROOM SERVICE.
6 PARKING
4 BEDROOMS 0.9 90
9 LOCKERS + 0.2 20
WASHROOMS
10 PANTRY 0.4 40
7 READING
THE FIRST FOUR FACTORS LISTED ABOVE ARE OF COURSE ALL INTERRELATED AND MUST
BE ORGANIZED AS A COMPATIBLE GROUP .
PROVISION OF BASEMENT
• Basement in case of plotted development if constructed shall not be included in FAR.
• Basement area shall not exceed the ground floor coverage.
HOTEL (4 STAR)
• It must have a minimum plot size of 5000 sq. mt.
• F.A.R is allowed upto 3 ( 20-25% of this FAR can be used for commercial purposes)
• Ground coverage upto 40%
• Parking -1 ECS per 100 sq. mt. of covered area
SERVICE AREA
PUBLIC
SEMI-PRIVATE
PRIVATE
ADMINISTRATIVE AREA
VERTICAL-CIRCULATION
GUEST AREA SERVICES
GUEST CIRCULATION
SERVICE
CIRCULATION
ADAPTABILITY ORIENTATION
POTENTIAL FOR FUTURE FOR SUNLIGHT AND
DEVELOPMENT VENTILATION
CIRCULATION
THE MOVEMENT OF GUESTS,
NONRESIDENT VISITORS, STAFF
ACCESS ROUTES AND SUPPLIERS IN A HOTEL CAR PARKING
SEPARATE GUEST TEND TO FLOW DISTINCT SPACE DEPENDS ON
ENTRY FROM SERVICE CIRCULATORY PATTERNS. THE LOCATION,
ENTRY WHERE PRACTICAL GUEST, PATTERNS OF USE ,
SUPPLY AND STAFF TRANSPORT MODE .
CIRCULATION BE KEPT
SEPARATE.
35
LOBBY + 30
RECEPTION
25 OPEN AREA
20 BASEMENTS
15 STILTS
VEHICLES COVERED
COVERED
DRIVEWAY 10 PODIUM
DRIVEWAY ROOF TOP
5
0
DIVISION OF ECS
I) OPEN AREA : 23 SQ.M PER E.C.S
PROPERTY
ENTRANCE
II) BASEMENTS : 32 SQ.M PER E.C.S
III) STILTS: 28 SQ.M PER E.C.S
IV) PODIUM: 28 SQ.M PER E.C.S
V) ROOF TOP: 28 SQ.M PER E.C.S
13%
Banquets,Meeting and Conference Rooms (4-12%)
TOPIC NEUFERT’S
WAITING RECEPTION 10
AREA
FRONT DESK 15
OFFICES : 102
MANAGER 14
ENTRANCE DIRECTOR 14
RECEPTION CORE
SECRETARIAL 9.2
SALES AND 13
RESERVATION 14
ACCOUNTS
ADMINISTRATION
OFFICES STORAGE 9.2
WORKSTATION 23-45
BUILDING
SERVICES
ACTIVITIES AREAS(SQ.FT)
LAUNDRY 700
LIFTS SERVICE LIFT + CIRCULATION AREA = 160 IN A DUAL LINE ARRANGEMENT : LOBBY =1.5 TIMES
SQ.MT TO 2.5 TIMES THE DEPTH OF ONE CAR.
FOR IN-LINE ARRANGEMENTS : LOBBY =HALF OF
THE ABOVE RECOMMENDATIONS.
SHAFT
DOOR
LIFT CAR
PASSENGERS 5 8 13
NAME WIDTH
STANDARD LAYOUT
STAFF
CIRCULATION
SECTIONS
PLANS
BAR AREA
STAFF KITCHEN
BAKERY
GLASS
WASHING
AREA
FISH DAIRY
VEGETARIAN PRODUCTS
COLD
PREPARATION
STORE
KITCHEN
MAIN
RESTAURANT DISHWASHING
MEAT
MEAT COLD
PREPARATION STORE
PANTRY
DRINKS
DRINKS LEGEND :
COLD
SERVERY
STORE
CIRCULATION
SPECIALITY
RESTAURANT
CORRIDOR
TOILETS
VENTILATOR
REFERENCE : NEUFERTS STANDARDS
SHEET NO. ARCHITECTURAL DESIGN REMARKS SUBMITTED BY :
1) ANUBHA ARORA (006) 8) YAJAS GUJRAL (031)
2) TANISHA SACHDEVA (009) 9) SUNAYANA MIGLANI (033)
38 LITERATURE STUDY
3)
4)
SHUBHAM SARIN
NIMISHA BHAGAT
(011)
(015)
10)
11)
PRASHANT BATRA
SONALI SINGH
(036)
(039)
5) APRAJITA MALHOTRA (019) 12) SOORAJ ARORA (040)
6) SHREEYA SHARMA (025) 13) SANYAM CHANANA (042)
7) MOLLIEE SETH (030)
HOTELS OFFER DIFFERENT TYPES OF FACILITIES FOR HANDICAPPED AND DISABLED
ACCOMODATIONS , INCLUDING 1) ATLEAST 1-2% OF ROOMS (PREFFERED ON GROUND FLOOR)
1) BEDROOMS 2) RAMPS – 1:20
2) SELF CATERING UNITS 3) CORRIDORS - .915M
3) APARTMENTS 4) DOORS - .815M (CLEAR OPENING)
ALL OF WHICH USE HOTEL SERVICES 5) BATHROOMS :
a) CENTRAL TURNING SPACE -1.52M
ROOMS INCLUDE : b) WIDTH – 2.75M
1) SITTING AREA WITH CHAIRS c) VANITY TOPS - .860 M HIGH
2) A DESK d) KNEE SPACE- .685M
3) TV CUPBOARD e) TOILET SEAT HEIGHT - .430M
4) SELF SERVICE DRINLS REFRIGERATOR f) GRAB BARS –TO BE PROVIDED ON HEADWALL AND SIDES
5) SUITCASE STANDS 6) BEDROOMS:
a) WIDTH- 3.65 M
SOME POINTS TO BE CONSIDERED : b) SPACE BETWEEN BEDS AND FURNITURE - .910M
1) CORRIDOR SPACE : 6 SQ.M PER ROOM c) BEDS- .450-.500M HIGH (WITH TOE SPACE)
2) CORRIDOR WIDTH : 1.5M-1.8M d) EYE LEVEL FOR WHEELCHAIR – 1.07-1.37M
3) SEPARATE ROUTES FOR – GUESTS, 7) LOW WINDOW SILLS -PREFERRED
SERVICE AND GOODS.
DIMENSIONS : IN CMS
REFERENCE : NEUFERTS STANDARDS
SHEET NO. ARCHITECTURAL DESIGN REMARKS SUBMITTED BY :
1) ANUBHA ARORA (006) 8) YAJAS GUJRAL (031)
2) TANISHA SACHDEVA (009) 9) SUNAYANA MIGLANI (033)
40 LITERATURE STUDY
3)
4)
SHUBHAM SARIN
NIMISHA BHAGAT
(011)
(015)
10)
11)
PRASHANT BATRA
SONALI SINGH
(036)
(039)
5) APRAJITA MALHOTRA (019) 12) SOORAJ ARORA (040)
6) SHREEYA SHARMA (025) 13) SANYAM CHANANA (042)
7) MOLLIEE SETH (030)
S.NO. SANITARY FOR RESIDENTIAL FOR NON RESIDENTIAL STAFF
UNITS PUBLIC STAFF FOR MALE FOR FEMALE
1. WATER CLOSET ONE PER 8 PERSONS. OMITTING 1 FOR 1-15 PERSONS 1 FOR 1-12 PERSONS
(W.C.) OCCUPANTS OF THE ATTACHED WATER 2 FOR 16-53 PERSONS 2 FOR 13-25 PERSONS
CLOSET. MIN. 2 IF BOTH SEXES ARE 3 FOR 36-66 PERSONS 3 FOR 26-40 PERSONS
LODGED. 4 FOR 66-100 PERSONS 4 FOR 41-57 PERSONS
5 FOR 58-77 PERSONS
6 FOR 78-100 PERSONS
2. ABLUTION TAPS ONE IN EACH W.C. ONE IN EACH W.C. ONE IN EACH W.C.
7. KITCHEN SINK ONE IN EACH KITCHEN ONE IN EACH KITCHEN ONE IN EACH KITCHEN
2. ABLUTION TAPS ONE IN EACH W.C. ONE IN EACH W.C. ONE IN EACH W.C. ONE IN EACH W.C.
4. WASH BASINS ONE FOR EACH W.C. ONE FOR EACH W.C. ONE FOR EACH W.C. ONE FOR EACH W.C.
5. KITCHEN SINKS ONE IN EACH KITCHEN ONE IN EACH KITCHEN ONE IN EACH KITCHEN ONE IN EACH KITCHEN
AND DISH
WASHERS
NEARER
NEAR
FAR
81-90
91-100
OUTSTANDING PERFOR
SILVER 50 - 59 50 - 59
MANCE
CONSTRUCTION WASTE
CREDIT 2 MANAGEMENT, DIVERT 50% OR UP TO 2
75%
LEED ACCREDITED
CREDIT 2 1
PROFESSIONAL
PROJECT TOTALS 25 - 34