LUBE OIL AND H.P.

SEAL OIL DIAGRAM FOR RECIPROCATING COMPRESSOR (TYPICAL)

PDP

TI PI PS

Pressure
control

L.O. filters RV

Driver Gear
M

L.O. pumps

L.O. coolers Direct from


crankcase oil bath

or use oil tank

L.O. tank HP seal pumps

Seal oil tank


COOLING WATER DIAGRAM FOR RECIPROCATING COMPRESSOR (TYPICAL)

Water jaclet
Gas out

Gas in

1'st stage-A
3'rd stage

L.O. coolers
Intercooler-II

1'st stage-B 2'nd stage

C.W. return

Water jaclet

Intercooler-I
C.W. supply
RECIPROCATING COMPRESSOR CONTROL (TYPICAL)

Trip signal from L.O. IA


Vent or bypass
Trip signal from system Compressor control
system
Capacity requirement signal

Permissive start
Instrument air PS

PS

RV, vent
or to
suction

Gas

Suction valve unloader

Permissive start
Clearance pocket

M Starting device

Trip
M
Intercooler
Motor driver

RV, vent
or to
suction