Inlet Stream-2

Temperature 120.0 F
Pressure 7.500 psig
Molar Flow 0.00000091 MMSCFD
101 109
LP
Comp Temperature 130.0 F
Clr Pressure 390.0 psig
105 Std Gas Flow 30.88 MMSCFD
H2O-2 106 151
Water Content 6.906 lb/MMSCF Temp
Q-107 HC Dew Point 117.6 F Above
LP LP Q-108 Hydrate
Inlet Sat SuctScrub Comp
Stream-2 Feed-2 T R
SAT-101 101 G/G 103 107 108 108R Temp Above Hydrate
LP G/L MRU RCY-1
HEX Gas/Gas HEX 50.87 F
Liqs HEX
Pump 108
G/G HEX Gas/Liq HEX 48.66 F
G/L HEX 35.00 F Cold
104 152 153 Cold Sep Ovhd Gas 12.27 F
VLV-100 Duty 2320750 Btu/hr Duty 76950.231 Btu/hr Sep
Q-109 Min App 30.00 F Min App 15.00 F
UA Calc 69695 Btu/F-hr UA Calc 3163 Btu/F-hr
129 110
Inlet Stream-1
122 TEG After
Temperature 130.0 F Scrubber
Vapour Fraction 0.9442 110
Pressure 425.0 psig
Temperature 120.0 F 617.2 barrel/day
Vapour Fraction 0.6198
Pressure 400.0 psig StabOvhd
Mass Flow 4376 lb/hr 125 Clr
Std Gas Flow 30.00 MMSCFD
126 113
Mole Frac (CO2) 0.004900 129 128 114
Mole Frac (N2) 0.003200 H2O-1 113 121.5 F Stabilized Condensate
SuctScrub PCV-104
Mole Frac (C1) 0.809400 80.00 psig
120 Q-102 Temperature 120.4 F
Mole Frac (C2) 0.052400 Q-101 1.029 MMSCFD 118
TEG StabOvhd Pressure 0.5000 psig
Mole Frac (C3) 0.047600 Inlet Sat Q-100 Unit Comp 0.0000 lb/hr
Stream-1 Feed-1 127
Mole Frac (i-C4) 0.014200 SAT-100 111 LCV-105
112 Actual Liquid Flow 64.85 USGPM
StabOvhd Comp 111
Mole Frac (n-C4) 0.014200 R 118
Actual Volume Flow 2223 barrel/day
Inlet 123 Adia Eff 60 59.10 F 119 119R
Mole Frac (i-C5) 0.007300 MIX-104 RCY-2 Reid VP at 37.8 C -4.895 psig
Sep Delta P 360.0 psi 370.0 psig
Mole Frac (n-C5) 0.006500 Q-StabReb Product
Power 135.9 hp 629.3 barrel/day Cooler
Mole Frac (C6) 0.007200
Mole Frac (C7) 0.002700 133 116 117
121 132 115 LCV-101
LCV-100 Stabilizer
Mole Frac (C8) 0.002000 Condensate Stabilized
133 121 Q-Cooler Tank Condensate
Mole Frac (C9) 0.001600 Stabilizer 115
Mole Frac (n-C10) 0.0031 0.0288 USGPM 117.7 F 289.0 F
Reboiler Duty 2970538 Btu/hr
0.9868 barrel/day 400.0 psig Metering
Mole Frac (n-C11) 0.0027 83.00 psig Residue Gas
Mole Frac (n-C12) 0.0020 64.02 USGPM 146 Residue Temperature 119.3 F
2195 barrel/day Gas
Mole Frac (n-C13) 0.0016
Pressure 1150 psig
Mole Frac (n-C14) 0.0013 140 144
136 1stStg 2ndStg ResGas Std Gas Flow 30.03 MMSCFD
Mole Frac (n-C15) 0.0010 Clr Clr FiltClscr
Mole Frac (n-C16) 0.0007 2ndStg Disch Molecular Weight 19.74
1stStg 138 139 Scrub 142 143 Scrub
Mole Frac (n-C17) 0.0005 134 134
PCV-103
135 Scrub 147 HC Dew Point 34.06 F
Mole Frac (n-C18) 0.0004 Temperature 100.0 F 1stStg 2ndStg Water Content 7.006 lb/MMSCF
Mole Frac (n-C19) 0.0003 Comp Q-104 Comp Q-105 Q-106
Pressure 370.0 psig Q-103 145 Water Dew Point 38.32 F
Mole Frac (n-C20) 0.0010 Std Gas Flow 30.03 MMSCFD 137 141
Higher Heating Value 1181 Btu/SCF
Higher Heating Value 1461 Btu/SCF Molecular Weight 19.74
2ndStg Comp Lower Heating Value 1078 Btu/SCF
Lower Heating Value 1340 Btu/SCF HC Dew Point 34.71 F 1stStg Comp
Adia Eff 70
Water Dew Point 18.73 F Adia Eff 70
Press Ratio 1.735
Higher Heating Value 1181 Btu/SCF Press Ratio 1.820
Power 1109 hp
Lower Heating Value 1078 Btu/SCF Power 1214 hp
Delta P 503.0 psi
Delta P 313.0 psi

Fri Jun 19 04:28:58 2020 Case: GTR - Duport Energy 30MM MRU Plant Rev A.hsc Flowsheet: Case (Main)
PROPANE REFRIGERATION UNIT
403 402

413 PCV-403
402
Temperature 34.28 F 5418 lb/hr
Pressure 51.24 psig
Mass Flow 13543 lb/hr Condenser
Mass Density (Vap Ph) 0.6061 lb/ft3 Duty 2899139 Btu/hr 409
Viscosity (Vap Ph) 0.0077 cP 411 125.0 F
410 Condenser
Z Factor 0.9006 407 408 409 257.3 psig
MIX-100
412
413
Suction
Scrubber Q-Condenser 401
Q-1 Q-2
1st Stg Comp 2nd Stg Comp Accumulator 65.93 F
Q-heater Comp Comp 108.0 psig
E-101
414
1st Stg Comp 2nd Stg Comp 400 401 Economizer

Adiabatic Efficiency 52.5 Adiabatic Efficiency 52.5 LCV-400


Delta P 54.76 psi Delta P 161.3 psi
Power 125.1 hp Power 258.9 hp 400
406 Mole Frac (Ethane) 0.0250
Mole Frac (Propane) 0.9750

406
To Chiller
29.28 F Chiller
Duty 1894288 Btu/hr
51.74 psig
Cold Chiller Min Appr 7.000 F
Process
Data Stream UA 99553.8 Btu/F-hr
Total Refrig Compression 384.0 hp
405 404
Data Mass Flow of Refrigerant 18961.0 lb/hr
LCV-402

Fri Jun 19 04:26:41 2020 Case: GTR - Duport Energy 30MM MRU Plant Rev A.hsc Flowsheet: MRU (TPL1)