You are on page 1of 1

Page 1 of 1

1 MEXICHEM RESINAS COLOMBIA S.A.S 6 SPECIFICATION IDENTIFICATIONS


2 TAG: SPFM 001 Specification for 7 Document No IP-DMA-001
3 PID: DMA1 Flow Meters 8 Latest revision B Date 10/07/2020
4 9 Issue status Approved for Quotation
5 10
11 FLOWMETER BODY AND HOUSING 58 TOTALIZER INDICATOR
12 Body/Housing type In-line (std by vendor) 59 Totalizer type N/A
13 End conn nominal size BY VENDOR 150# 60 Enclosure type no/class N/A
14 End conn termn type Flanged Rating R.F. 61 Signal Power source N/A
15 Body wetted material 304 SS 62 Contacts arrangement N/A Quantity N/A
16 Housing material 304 SS 63 Totalizer reset style N/A
17 End termination material 304 SS 64 Integral indicator style N/A
18 65 Cert/Approval type N/A
19 66 Mounting location/type N/A
20 FLOWTUBE ASSEMBLY 67 Enclosure material N/A
21 Flowtube type Parallel curved tubes 68
22 Flowtube diameter BY VENDOR 69 PERFORMANCE CHARACTERISTICS
23 Flowtube material 304 SS 70 Max press at design temp Note 1 At Note 1
24 Permitted flowtube diameter < or = to line nominal size 71 Min working temperature Note 1 Max Note 1
25 72 Mass flow rate accuracy ´+/- 0.1% for liquid and 0.5% for gas
26 73 Density accuracy rating 0.001 g/cm3 for liquid
27 74 Min flow URL Note 1 Max Note 1
28 CONNECTION HEAD 75 Density LRL Note 1 URL Note 1
29 Housing type explosion proof enclosure 76 Sec enclosure press rating Note 1
30 Enclosure type no/class NEMA 4X&7, Class 1,Div 2,Gr. CyD 77 Pressure drop at flow URL Note 1
31 Signal termination type Terminal Block 78 Min ambient working temp Note 1 Max Note 1
32 Cert/Approval type FM explosion proof 79 Contacts ac rating N/A At max N/A
33 Housing material 304 SS 80 Contacts dc rating N/A At max N/A
34 81 Max sensor to receiver Ig Note 1
35 82
36 83 ACCESSORIES
37 REMOTE TRANSMITTER OR COMPUTER 84 Connecting cables length 6 meters
38 Housing type explosion proof enclosure 85 Heating Kit style N/A
39 Measurement compensation Density 86 Calibrator/configurator N/A
40 Output signal type Foundation Fieldbus 87
41 Enclosure type no/class NEMA 4X&7, Class 1,Div 2,Gr. C,D 88
42 Span-zero adjustment Local Keypad, Hand Held & PRM softw 89 SPECIAL REQUIREMENTS
43 Characteristic curve Linear mass flow 90 Custom tag SPFM 001
44 Digital communication std Foundation Fieldbus 91 Reference specification N/A
45 Signal power source 120 VAC, 60 Hz 92 Special preparation N/A
46 Failsafe style Failsafe selectable 93 Compliance standard N/A
47 Integral indicator style LCD Display 94 Calibration report Yes, 10 points mass flow calibration
48 Signal Termination type Terminal Block 95 Software configuration Custom configuration
49 Cert/Approval type FM explosion proof 96
50 Mounting location/type Remote/ 2 in pipe bracket 97 PHYSICAL DATA
51 Failure/Diagnostic action Drive output high 98 Estimated weight Note 2
52 Enclosure material Epoxy coated aluminum 99 Face-to-face dimension Accordance to ASME B 16.10
53 100 Overall height Note 2
54 101 Removal clearance Note 2
55 102 Signal conn nominal size 1/2 in Style NPT(F)
56 103 Mfr reference dwg N/A
57 104
110 CALIBRATIONS AND TEST INPUT OR TEST OUTPUT OR SCALE
111 TAG NO/FUNCTIONAL IDENT MEAS/SIGNAL/TEST LRV URV ACTION LRV URV
112 SPFM 001 Mass flow-Analog output
113 Meas-Analog output 2
114 Meas-Analog output 3
115 Meas-Freq output 1
116 Meas-Freq output 2
117 Measurement-Scale 0 kg/hr 2400 Kg/hr
118 Temp-Digital output
119 Meas-Digital output
120 Density-Digital output
121 Test pressure
122 COMPONENT IDENTIFICATIONS
123 COMPONENT TYPE MANUFACTURER MODEL NUMBER
124 Flowmeter MicroMotion
125 FlowTransmitter MicroMotion
126
127
Rev Date Revision Description By Appy1 Appy2 Appy3 REMARKS
Note: 1 Vendor must furnish performance caracterisct.

Note: 2 Vendor must furnish physical data.

B 10/07/2020 Approved for Quotation OG/JM OR

Form: 20F2521 Rev 0 © 2001 ISA