Professional Documents
Culture Documents
OUTPUT MODULES
PDU 40 01 1-port PoE Injector with surge
protection
PDU 40 02 1-port PoE Injector with lightning
protection on PoE port
PDU 40 03 2-port 55 VDC module with lightning
protection
OUTPUT POWER
POWER 6393 total output ≤200 W
power
PDU 40 01 IEEE 802.3at: ≤31 W or
ERICSSON proprietary: ≤100 W
PDU 40 02 IEEE 802.3at: ≤31 W or
ERICSSON proprietary: ≤100 W
PDU 40 03 Power ≤200 W
(each port can handle all available
power)
OUTPUT VOLTAGE
PDU 40 02 All modules 55 V
PROTECTION
Over Voltage Protection Yes
Short Circuit Protection Yes (per module)
Surge Protection Yes (all ports)
Lightning Protection Yes (PDU 40 02 and PDU 40 03)
EMC
Conducted Emission CLASS B, EN 55022
Radiated Emission CLASS B, EN 55022
SUPERVISION
PDU 40 03 LED indicators Power, fault, warning
ETHERNET SUPPORT
Up to 10 m + 90 m cables Channel Link Class D according to
ISO 11801
MECHANICAL
Dimensions 200 x 200 x 100 mm
Weight 3 kg
Placement Indoor, Outdoor
Mounting Wall, Pole
Water/dust protection IP66 (IEC 60529), Type 3 (UL 50E)
Ericsson AB
SE-417 56 Göteborg, Sweden
Telephone +46 10 719 00 00 28701-FGC 101 3416 Uen, Rev B
www.ericsson.com © Ericsson AB 2017