You are on page 1of 3

Stage: 1st

No. of Strands: 19
Jacking Force: 3715 KN
Jack Ram Area: 1045.4 cm2
Theorotical Elongation : 176 mm (Including Grip length)
Theorotical Area of Strand: 140 cm2
Theorotical Modulous of Elasticity (Es): 1.95 X 105 N/mm2
Actual E: 2.04 X 105 N/mm2
Actual Area: 147.11 mm2
Efficiency of Jack: 98 %

Modified Guage pressure = 369.64 kg/cm2


Max. Guage pressure (+5%) = 388.12 kg/cm2
Min. Guage pressure (-5%) = 351.16 kg/cm2

Modified Elongation = 160.10 mm


Max. Elongation (+5%) = 168.11 mm
Min. Elongation (-5%) = 152.10 mm

Stressing Sheet e.g.


Pressure Piston Reading Elongation Slack Actual Elongation
50 57 26
100 83 26 31 52
150 109 26 78
200 135 26 104
250 161 26 130
300 187 26 156
350
Breaking load (Class 2) of Strand : 260.7 KN
UTS of Strand (Fy) = 1862.143 N/mm2
Length of Cable (L) : 24061 mm Jack Length: 660
Elongation = Fy * L * Friction Loss
Es

Avg. stress after FrictionCable-1 = 0.7305


Cable-2 = 0.733
Cable-3 = 0.736

Elongation in cable = 169.1102266 mm


Elongation in Jack= 6.302637363 mm
mm