VISTA-128BPT SERIES

PARTITIONED COMMERCIAL BURGLARY


ALARM CONTROL PANELS

The VISTA-128BPT is a powerful member of the Honeywell The VISTA-128BPT and VISTA-128BPTSIA are listed for
family of commercial alarm panels, integrating burglary, CCTV residential burglary, residential fire and commercial burglary
and access control functions. Many features are available that applications (see agency listings in this document for
extend the applications of the VISTA-128BPT while simplifying more details). They are compatible with a wide range of
end-user operation. AlarmNet communications products for alarm reporting,
uploading /downloading and remote services.

FEATURES
Standard features • Zone 7 may be used for keyswitch • Group bypass
(VISTA-128BPT and VISTA-128BPTSIA): arming/disarming • Arm faulted
• Provides nine style-B hardwired zones • Integrates with WIN-PAK access • Event arming
• Supports up to 119 additional zones control systems to provide increased
users, event log and scheduling • Carbon monoxide (CO) zone
using a built-in polling (V-Plex®,
type support
multiplex) loop interface • Supports V-Plex addressable
VistaKey access control (up to eight • Expanded high-speed RS-232
• Supports up to 127 wireless zones
doors and 250 cards) capability for third party interface
using up to two 5800 series wireless
and automation
receivers (fewer if using hardwire • Easily programmed and maintained
and/or polling loop zones) by Compass Windows-based • Internet upload/download
downloader over AlarmNet GSM and/or
• Provides one power-limited bell circuit
IP communicators over the panel's
delivering 1.7Amp (max) at 12VDC • Supports up to 96 programmable keypad (ECP) bus
• Provides the ability to control eight outputs
• Ringback support for AlarmNet
separate partitions independently, • Programmable to meet SIA false communicators (confirmation of
each functioning as if it had its own alarm prevention specifications. closing report)
separate control To meet UL approval for ANSI/SIA
CP-01-2010, order part number • 24-hour dialer test support for
• Accommodates 150 user codes with
V128BPTSIA AlarmNet devices
seven authority levels
• Supports up to six touchscreen • Supports V-Plex Smart Contact
• Accommodates 32 keypad macro
Advanced User Interface (AUI) feature for improved responsiveness
commands per system
devices (6272 or later) on systems with many V-Plex zones
• Keeps a log of up to 512 events
• Smoke detector reset at keypad • Telco line cut detection
• Supports up to 16 compatible
two-wire smoke detectors on zone 1 • Quick exit
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS
ADDITIONAL FEATURES
Basic Hardwired Zones Wireless Expansion Eight Partitions
Provides nine style-B hardwired zones Supports up to 127 wireless zones Provides the ability to control eight
with the following characteristics: using up to two 5800 Series wireless separate areas independently, each
• EOLR supervision (optional for zones receivers (fewer if using hardwire functioning as if it had its own separate
2-8) supporting N.O. or N.C. sensors and/or polling loop zones). control. Partitioning features include:
(EOLR supervision required for fire Wireless zones have the following • A Common Lobby partition (1-8),
and UL burglary installations) characteristics: which can be programmed to arm
• Individually assignable to one of • Supervised by control panel for automatically when the last partition
eight partitions check-in signals (except certain that shares the common lobby is
non-supervised transmitters) armed, and to disarm when the first
• Up to 16 two-wire smoke detectors
partition that shares the common
on zone 1 • Tamper protection for supervised
lobby is disarmed
• Four-wire smoke or heat detectors transmitters
• A Master partition (9), used strictly to
on zones 1-8 (power to four-wire • Individually assignable to one of
assign keypads for the purpose of
smoke detectors must be supervised eight partitions
viewing the status of all eight partitions
with an EOL device). Listed for Scheduling at the same time (master keypads)
residential fire only.
Provides the following scheduling • All zones assignable to one of
Polling Loop Expansion capabilities: eight partitions
Supports up to 119 additional zones • Open/close schedules (for control of • Keypads assignable to one of eight
using a built-in polling (V-Plex, multiplex) arming/disarming and reporting) partitions or to Master partition 9 to
loop interface. Current draw can total
• Holiday schedules (allows different view system status
up to 128mA. Polling loop zones have
time windows for open/close • Ability to assign relays to one or all
the following characteristics:
schedules) eight partitions
• Must use V-Plex devices
• Timed events (for activation of relays, • Ability to display fire and/or burglary
• Supervised by control panel auto-bypassing and unbypassing, and panic and/or trouble conditions
• Individually assignable to one of auto-arming and disarming, etc.) at all other partitions’ keypads
eight partitions • Access schedules (for limiting system (selectable option)
• Supports VSI Module access to users by time) • Individually programmable account
• Supports 4297 Expander Module • End user output programming mode number, entry delay and exit delay
• Maximum wiring distance = (provides 20 timers for output control) by partition
12,000 feet

V-Plex Loop

5193
4101SN DT7500SN FG1625SN Glassbreak 4208EX Eight-zone 4293SN Adapters Series Smoke Detectors
Relay Module V-Plex DUAL TEC V-Plex Expander and
Motion Sensor 4208SN Serialized Eight-zone
Remote Point Module 5881
ECP Bus Wireless
Receiver

6160
Console
710
Strobe
Light VISTA-128BPT
4204
Notification Relay
Appliances Keyswitch Module
Option
4146

Serial Printer PC Connection Phone Line to Central Station


748
Horn
RS-232
or or
7847i GSMV iGSMV

NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information.
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS

ACCESSORIES
Auxiliary Devices Passive Infrared Detectors • 5819 - Shock Sensor
• 4204 - Relay Module, four form • IS2500SN • 5827BD - Bidirectional Keypad
C contacts
• DT7500SN • 5853 - Glassbreak Detector
• 5881 Series - RF Receiver supporting
V-Plex (Addressable) Contacts • 5898 - Wireless DUAL TEC
5800 wireless detectors
Motion Sensor
• 4939SN-WH
• 6160 - Alpha Keypad/Annunciator
• 5800PIR-OD - Outdoor Motion Sensor
• 4944SN-WH
• 6220S - System Printer
• 5870API - Asset Protection Device
• 4959SN
Manual Pull Stations
• 5800PIR/5800PIR-RES/5800PIR-COM
V-Plex Glassbreak Detectors
• 5140MPS-1 - Wireless Motion Detectors
• FG1625SN
• 5140MPS-2 • 5800CO (5800COA - Canada) -
VISTA Interactive Phone Module Wireless Carbon Monoxide Detector
V-Plex (addressable) Devices
• 4286 VIP Module • 5800RP - Wireless Repeater
• 4101SN Single Relay/Zone Module
Optional Communicators • 5808W3 (5808W3A - Canada) -
• 4190SN Remote Point Module -
Wireless Smoke Detector
two zones • AlarmNet Internet/Intranet
communicators and digital cellular • 5809 - Wireless Heat Detector
• 4193SN Two-zone Serial Interface
communicators
Module Commercial Listed
Access Control Wireless Devices
• 4208EX - Eight-zone expander for
ULC commercial installations • VISTAKey V-Plex (addressable) • 5817CB - Commercial UL Burglary,
Access Control Universal Contact Monitoring
• 4208SN Loop Expansion Module -
Transmitter*
eight zones • VISTAKey-SK Starter Kit
• 5869 - Commercial UL Wireless
• 4209U Group Zoning Module - • VISTAKey-EX Expansion Kit
Hold-up Button*
two/four zones
Wireless Devices
• 5881ENHC and 5883H Receivers
• 4293SN One-zone Serial
• 5804 - Wireless Key
Interface Module *When used with 5881ENHC and/or
• 5804BD - Bidirectional Key 5883H receiver.
• 4297 Isolation/Extender Module
• 5804BDV - Bidirectional Key
• VSI Short/Overload Isolation Module
with voice
• 5193SD
• 5816 - Door/Window Transmitter
• 5193SDT

4190SN 4959SN 4944SN


4193SN Remote Point Module Overhead Door Contact Contact
IS2500SN 4208U Two-zone Serial Interface Module
V-Plex PIR Eight-zone
Motion Sensor Expansion Module VISTAKey V-Plex
5808W3
5881ENHC (5808W3A - Canada) Glassbreak Detectors Access Control
Commercial Wireless Receiver Wireless Module
ECP Bus (Max Two) Smoke Detector 5800
Series
Wireless 5800PIR Series
6160 5816 Devices Wireless PIRs
Console Door/Window
Transmitter 4209U
Group Zoning
Module
5869
Commercial UL Supports Up To
Wireless Hold-up 5817CB Universal 16 Conventional
4204 Two-Wire
Relay Button Contact Monitoring Smoke Detectors
Module Transmitter
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS

SPECIFICATIONS
Agency Listed to the Electrical • Standby Time: Four hours min. with
Following Standards: • Voltage Input: From Honeywell No. 750mA aux. load using 7AH battery
• UL609 Grade A Local Mercantile 1361 Plug-In Transformer or • Circuit Protectors: PTC circuit
Premises and Mercantile Safe 1361X10 transformer (for X-10 breakers are used on battery input to
and Vault installations) rated 16.5VAC, 40 VA protect against reverse battery
• UL1610 Grades A, AA • Use 1361CN plug-in transformer connections and on alarm sounder
Central Station for Canada output to protect against wiring faults
(shorts). A solid state circuit breaker
• UL365 Grades A, AA Police Connect • Alarm Sounder Output:
is used on auxiliary power output to
• UL985 Household Fire 10VDC-13.8VDC, 1.7 amps max.,
protect against wiring faults (shorts).
(UL1023, UL609 installations);
• UL1023 Household Burglar Alarm Main Dialer
750mA less aux. current draw
California State Fire Marshall (CSFM)
(UL985 installations) • Formats Supported: ADEMCO
• UL1635 - Digital Alarm Contact ID with support for four-digit
• Auxiliary Power Output: 9.6VDC-
Communicator System Units and ten-digit accounts and
13.8VDC, 750mA max. For UL
• CAN/ULC - S303 installations, the accessories ADEMCO 4 + 2 Express
• CAN/ULC - S304 connected to the output must be UL • Line Seize: Double Pole
• CAN/ULC - S545 Listed, and rated to operate in the • Ringer Equivalence: 0.7B
above voltage range
• CAN/ULC - S1023 Cabinet Dimensions
• Backup Battery: 12VDC, 4AH or 7AH
• For commercial burglary attack 12-1/2" W X 14 1/2" H X 3" D
sealed-lead acid. YUASA NP4-12
proof requirements, use N5873V4BE (12V, 4AH) or NP7-12 (12V, 7AH)
attack proof enclosure provided in recommended
VISTA-ULKT kit

ORDERING
VISTA-128BPT Commercial Burglary Alarm Control Panel (UL Listed)
V128BPTSIA SIA Approved Enhanced Commercial Burglary Alarm Control Panel (UL Listed)
V128BPTCNKT VISTA-128BPT Commercial Burglary Alarm Control Panel with 1361CN Transformer (Canada only)

For more information:


www.honeywell.com/security/hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
L/VSTA128BPTD/D
1.800.467.5875 April 2011
www.honeywell.com © 2011 Honeywell International Inc.