FOR YOUR SAFETY - This product must be installed and serviced by authorized person-
nel, qualified in pool/spa heater installation. Improper installation and/or operation can
create carbon monoxide gas and flue gases which can cause serious injury, property
damage, or death. For indoor installations, as an additional measure of safety, Jandy Pool
Products, Inc. strongly recommends installation of suitable Carbon Monoxide detectors in
the vicinity of this appliance and in any adjacent occupied spaces. Improper installation
and/or operation will void the warranty.
Installation and
Operation Manual
XL-3®
Oil-Fired Pool
and Spa Heater
Model DP3000
No.2 Fuel Oil Only
WARNING
If these instructions are not followed exactly, a fire or explosion may result,
causing property damage, personal injury, or death.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
SECTION 10.
Replacement Parts
10.1 Ordering Information .................................... 26
10.2 Parts List .................................................... 26
10.3 Exploded View ............................................ 28
Warranty .................................................... Back Cover
Model DP Oil-Fired Heater Page 1
• Lack of awareness of impending hazard installation date, and name of the installer. Shipping
costs are not included in the warranty coverage.
• Failure to perceive heat The warranty does NOT cover damage caused
• Failure to recognize need to leave spa by improper assembly, installation, operation or field
modification. Also, damage to the heat exchanger by
• Physical inability to leave spa corrosive water is NOT covered by the warranty. See
• Fetal damage in pregnant women Section 8.1 for maintaining proper pool water
chemistry.
• Unconsciousness resulting in a danger of
drowning NOTE: Keep this manual in a safe place for future
reference when inspecting or servicing the heater.
1.3.2 Swimming Pool Energy Saving Tips
Jandy Pool Products, Inc. offers the following 1.5 Codes and Standards
recommendations to help conserve fuel and minimize The XL-3 pool and spa heater is certified by UL
the cost of operating your pool heater without (Underwriters Laboratory) as complying with the
sacrificing comfort. latest standard of UL726 "Oil-Fired Boiler Assemblies,
Oil-Fired Service Water Heaters and Swimming Pool
1. The American Red Cross recommends a maxi- Heaters", CAN/CSA-B140.12
mum water temperature of 78°F (25°C). Use an All Jandy heaters must be installed in accordance
accurate pool thermometer. A difference of 4F° with the local building and installation codes as per the
(2°C) , between 78°F and 82°F (26°C and 28°C), utility or authorities having jurisdiction. All local codes
will use as much as 40% more fuel. take precedence over national codes.
2. Carefully monitor the water temperature of your In the absence of local codes, refer to the latest
pool in the summertime. You can reduce heater edition of the following national codes for installation:
usage due to warmer air temperatures.
1. In the United States, "The Standard for the
3. Set the pump time clock to start the pump no Installation of Oil-Burning Equipment",
earlier than 6:00 AM during the pool heating NFPA-31.
season. This is the time when nightly heat loss
balances. 2. In Canada, "The Installation Code for Oil Burning
Equipment", CSA B139.
4. If the pool is only going to be used on weekends,
reduce the heater temperature control setting by Any changes to the heater, burner controls,
8 or 10 degrees during the week. Reset it to the burner orifices, wiring, draft diverter, or improper
78°F (25°C) level a day or so before you plan to installation may void the warranty. If change is
use the pool. required to any of the above, consult the factory.
5. During the winter or when on vacation for longer
than a week, shut down the heater by following 1.6 Technical Assistance
the shutdown instructions found on the inside of Consult Jandy Pool Products, Inc. or your local
the heater. Jandy distributor with any questions or problems
involving the specifications, installation, and operation
6. Where possible, shelter the pool from prevailing of your Jandy equipment. An experienced technical
winds with well-trimmed hedges or other land- support staff is ready to assist you in assuring the
scaping, cabanas, or fencing. proper performance and application of Jandy products.
For technical support call the Jandy Pool Products,
7. Always use a pool cover when practical. Besides Inc., Technical Service Department at (707) 776-8200
providing a valuable safety feature, a pool cover extension 260.
will reduce heat loss, conserve chemicals, and
reduce the load on filter systems. 1.7 Materials Installer Must Provide
1.7.1 Materials for All Applications
1.4 Warranty The following items are needed and are to be
The XL-3 heater is sold with a limited factory supplied by the installer for all XL-3 heater
warranty. Details are specified on the back cover of installations:
this manual and the home owner's guidelines. 1. The correct size and length of fuel line to supply
Make all warranty claims to an authorized Jandy fuel from the storage tank to the heater (see
representative or directly to the factory. Claims must Section 4.1 for correct fuel pipe size).
include the heater serial number and model (this
information can be found on the rating plate),
Model DP Oil-Fired Heater Page 3
2. A manually operated fuel valve to be installed in 11. Modification of Heater for High Altitude:
the fuel line near the storage tank. Adjustment of air shutter to obtain most efficient
combustion.
3. A 115V AC power supply and all wire and
conduit needed to supply electricity to the heater. 12. Shipping Weight:
A junction box is not needed at the heater, 315 lbs.
connections are made inside of the heater jacket.
1.8.2 Dimensions
1.7.2 Materials for Special Applications See Figure 1 for a diagram showing the heater's
In addition to the items listed above, the following exterior dimensions and dimensions to critical
items are needed for special applications. connections on the heater.
1. A factory authorized barometric draft control and
any vent pipe needed for indoor installations in
the USA and outdoor shelter installations in
Canada (see Section 3.2.2). Barometric draft
controls are available from any Jandy distributor.
1.8 Specifications
1.8.1 General Specifications
1. Installation Location:
Certified for use:
In the USA: Indoor and Outdoor
In Canada: Outdoor and Outdoor Shelter
2. Minimum Clearance From Combustible Material:
See Table 1 in Section 2.3.2
FRONT VIEW
3. Supply Fuel Type:
Certified for use with:
#2 Fuel Oil or # 2 Diesel Fuel.
4. Burner Rating:
315 BTU/Hr
5. Fuel Consumption:
2.25 GPH (US Gallons per Hour)
4. Water Pipe/Heater Connection:
1 1/2" Threaded Iron Pipe or
1 1/4" Unthreaded Iron Pipe or
1 1/2" Copper Tubing
7. Water Flow Rate:
Maximum: 60 gpm (228 lpm)
Minimum: 30 gpm (110 lpm)
8. Working Water Pressure:
Maximum: 75 psi
SECTION 2.
Installation Instructions
2.1 Introduction
WARNING
Improper installation or maintenance can cause
nausea or asphyxiation from carbon monoxide in flue
gases which could result in severe injury, or death.
For indoor installations, as an additional measure of
safety, Jandy Pool Products, Inc. strongly
recommends installation of suitable Carbon
Monoxide detectors in the vicinity of this appliance
and in any adjacent occupied spaces.
CAUTION
The XL-3 heaters are designed to operate at all Figure 2. Inner Stack.
altitudes. Adjustments to the air band and end
shutter of the burner can be made to compensate for before attaching the vent cap (outdoor installation) as
changes in altitude. Contact your Jandy shown in Figure 2. The XL-3 heater is also designed
Representative or Jandy Pool Products, Inc.'s for "Indoor" installations in the United States and
Customer Service Department for more information. "Outdoor Shelter" installations in Canada when
equipped with a barometric draft control and the
Install the XL-3 heater and vent systems in appropriately sized exhaust vent.
accordance with the procedures in this manual, local Check the Parts List (Section 10.2) of this
codes and ordinances, and in accordance with the manual for the correct Jandy vent cap part number.
latest edition of the appropriate national code (see For specific installation information see Section 2.3.5
Section 1.5 "Codes and Standards"). "Indoor and Outdoor Shelter Installations".
All oil-fired products require correct installation Water connections are provided on the right side
to assure safe operation. The requirements for pool of the heater but can be changed to the left side by
heaters include the following: reversal of the heat exchanger. It is best to handle
these preparations before the heater is installed in its
1. Field assembly (if required) final location. See Section 5.4 "Reversible Water
2. Appropriate site location (clearances) and Connections" of this manual for instructions.
flooring
3. Sufficient combustion and ventilation air
4. Properly sized fuel line.
2.3 Location Requirements
5. Proper electrical wiring
6. Adequate water flow 2.3.1 Introduction
This manual provides the information needed to CAUTION
meet these requirements. Review all application and When pool equipment is located below the pool
installation procedures completely before continuing surface, a leak from any component can cause large
the installation. scale water loss or flooding. Jandy Pool Products,
Inc. cannot be responsible for such water loss or
flooding or resulting damage.
2.2. Field Assembly
The XL-3 heater can be installed in a variety of The XL-3 heater may be installed indoors or
ways, some of them requiring preparation or assembly outdoors as outlined in later sections. Location of the
in the field. The XL-3 is shipped with the inner stack heater below or above the pool deck affects operation
packaged on top of the control panel door in the box of its water pressure switch. See Section 5.1 water
with the heater. The inner stack must be assembled piping for more information about this.
and installed before mounting the vent cap or vent Avoid placing the heater in locations where it can
pipe. To assemble the inner stack, remove the tape cause damage by water or condensate leakage. If this
and small envelope from the sheet metal coil. Expand is not possible, provide a suitable drain pan to catch
the coil until the holes on each end are aligned. Use and divert any leakage. The pan must not restrict the
the two screws supplied in the small envelope to air flow around the heater.
secure the ends together. Install the inner stack, 7" All criteria given in the following sections reflect
(18cm) diameter, on the collar of the flue collector
Model DP Oil-Fired Heater Page 5
TOP (CHIMNEY
CONNECTOR) 13 33.0 OPEN UNROOFED AREA
FRONT 24 61 24 61
2.3.4 Outdoor Installation The top surface of the heater must be at least
For outdoor configuration, the XL-3 heater must three (3) feet above any forced air inlet, or intake
be installed with a factory authorized vent cap installed ducts located within ten (10) feet horizontally.
over the inner stack. See Section 2.2, "Field Assembly" If the heater is installed under an overhang, there
must be a minimum clearance of 5 feet (1.5 m) above
for installation of the inner stack. See Section 10, the top of the heater and the structure should not
"Parts List" for instructions on ordering a factory overhang the heater more than 12 inches (0.30 m). The
authorized vent cap. area under the overhang must be open on three sides.
Locate the heater in an open, unroofed area. This prevents combustion gases from being diverted
Do not install the heater under a deck. Do not locate into living areas through doors, windows, or gravity
the heater below or adjacent to any doors, glass inlets.
openings, louvers, grills, etc., which connect in any If the heater is installed close to a structure,
way with an inhabited area of a building, even though protect it from rain water runoff with rain gutters on
the access might be through another structure (e.g., a the roof or other measures. Do not locate the heater
garage or utility room). In the United States there must near irrigation sprinkler systems that could spray water
be a minimum of four (4) feet (1.22 m) horizontally on it. Water from sprinklers may cause damage to
controls and electronic components.
and four (4) feet (1.22 m) vertically between the Avoid locations where wind deflection off nearby
heater exhaust point and any door, glass opening, or structures might cause downdraft conditions. Where
gravity inlet to a building. In Canada, the heater must downdraft conditions exist, locate the heater at least 3
be installed so that the exhaust point of the heater is at feet (0.91 m) from vertical surfaces (e.g., nearby
least ten (10) feet (3.0 m) from any building opening buildings and walls).
(see Figure 4).
2.3.5 Indoor and Outdoor Shelter
WARNING Installations
An outdoor shelter (Canada only) is an
United States
unoccupied enclosure which does not communicate
Do not install the heater with the top of the vent
directly with occupied areas. All indoor installations
assembly within 4 feet (1.22 m) horizontally and 4 and outdoor shelter installations require the addition of
feet (1.22 m) vertically of any opening into a building. a factory approved barometric draft control. The
barometric draft control must be installed without
Canada modification and in accordance with the instructions
Do not install the heater with the top of the vent provided by the manufacturer.
assembly within 10 feet (3.05 m) of any opening into These codes, standards and Jandy Pool Products,
a building. Inc. require that the heater be properly vented as
outlined in this manual. Proper ventilation of exhaust
and combustion air are essential for the safe and
efficient operation of the heater (See Section 3
"Venting").
Avoid locating the chimney termination in a ordinances take priority over national codes.
location susceptible to downdraft conditions, or near
ventilation inlets to the building. 2. Check the fuel supply to be sure that only #2 fuel
Jandy Pool Products, Inc. does not recommend oil or #2 diesel fuel will be used to supply the
"Common Venting" of fuel-fired products. However, heater. XL-3 heaters, as shipped from the
if no other alternative is available, when venting factory, are certified to operate at sea level but
multiple appliances through one common duct, each the burner air shutter can be adjusted to operate
appliance must have it's own barometric draft control the heater efficiently at high altitudes
(see Figure 6). Refer to "The Standard for the 3. Use the figures in Table 3 to size the fuel inlet
Installation of Oil-Burning Equipment", NFPA-31 or, in piping from the fuel storage tank to the heater.
Canada, "Installation Code for Oil Burning Equipment", Check all local codes for compliance before
CSA B139 for more information on multiple venting. installing the heater.
SECTION 4. 4. Always install the fuel filter provided with the
heater in the fuel inlet pipe just outside the heater
Fuel Connections jacket.
4.1 Fuel Supply and Piping 5. Install an approved shutoff valve at the fuel
Review the following general instructions before storage tank for service and safety.
continuing the installation. 6. Before operating the heater, test the complete
fuel supply system and all connections for leaks.
WARNING
The XL-3 pool and spa heater was designed for use All XL-3 heaters are equipped with two-stage
only with #2 fuel oil or #2 diesel. DO NOT ATTEMPT fuel units. This enables the heater to be connected
TO CONVERT THIS HEATER FOR USE WITH ANY with a either a single pipe or a two pipe fuel supply
OTHER TYPE OF FUEL. system. In locations where the fuel storage tank is
above the level of the heater inlet, a single pipe system
may be used. Jandy Pool Products, Inc. recommends a
1. Fuel piping installation must be in accordance two-pipe system, with a supply line and a return line
with all local or national codes that apply. Local between the heater and the tank (see Figure 7), for all
Page 10
Thermometer For
Testing Temperature
Rise
Figure 15. Inspection Hole Location. Figure 16. Heater's ON/OFF switch in OFF position.
Model DP Oil-Fired Heater Page 17
CAUTION
The water pressure switch should be adjusted to turn
the heater off when the pump is off. Setting the
switch to close at too low of a flow can damage the
appliance. Adjust the switch to turn the heater off,
not on.
The pressure switch is preset at the factory for
activation at 2 psi (14 kPa). However, it is adjustable
in the range of 0.5 psi to 15 psi. Adjust the pressure
switch only if any part of the filter system piping or
water level of the pool is 3 feet (0.91 m) or more
above or below the top of the heater jacket.
Do not adjust the pressure switch if the heater is
installed more than 15 feet (4.57 m) below or 6 feet
(1.83 m) above the pool surface. Consult your local
Figure 18. Initial Air Adjustment. Jandy representative for recommendations.
On some installations, the piping from the heater
6. Set the thermostat to the desired temperature. to the pool is very short. The back pressure could be
Until the pool water reaches a temperature of too low to trigger the pressure switch. If this happens,
approximately 70°F (21°C), there may be it may be necessary to install a directional fitting or
condensate on the heat exchanger. This will stop elbows where the return line enters the pool. This will
after the water reaches the right temperature. increase back pressure enough for the heater to
If the heater is installed in an enclosed area, keep operate properly.
all doors and windows open during the first two hours Make sure the pool filter is clean before making
of operation. After a long shutdown, there may be any pressure switch adjustment: A dirty filter will
some smoke-like emissions from the heater when it is restrict the water flow and the pressure switch cannot
first fired. This condition will only last a few minutes. be adjusted properly.
To adjust the pressure switch, proceed as
follows:
7.5. Setting the Time Clock
The most economical and trouble-free way of 1. Set the heater control to the "OFF" position.
operating a pool heater and filter system is to include a
time clock in the system for automatic cycling. 2. Start the filter pump and confirm by means of an
Adjust the stops on the time clock to provide a meter that the pressure switch closes. If the
single filter cycle every 24 hours. switch fails to close call your Jandy
The ON cycle should be at least 12 hours to representative or the Jandy Pool Products, Inc.
allow the filter system to properly clean the pool. Set Technical Service Department at 707.776.8200
the ON cycle at least 4 to 6 hours before the pool is to extension 260.
be used. During cold spells, the heater may have to be
on longer to maintain the proper pool temperature. 3. Turn the thermostat to the maximum setting and
Remove all stops on the time clock during these set the heater control to the 'ON' position. The
periods. heater should start.
IMPORTANT: Run the heater continuously 4. Turn the thumb wheel on the pressure switch
during the initial warm-up period by removing all time very slowly clockwise until the heater goes off.
clock stops. If the pool temperature is going to be
maintained on standby temperature, operate the filter 5. Slowly turn the pressure switch thumb wheel
pump until the water temperature reaches 70°F counterclockwise one-quarter turn. The heater
should come back on.
(21°C). If the pool is going to be used for swimming,
bring the water up to swimming temperature before
replacing the time clock stops.
4. Remove both drain plugs from the heater. One is 5. If a circuit breaker was switched off during the
located on the right side of the inlet/outlet header winter, be sure that the breaker is back on.
(see Figure 20), The other is located on the left
side of the heater in the return header. Com- 6. Turn on the heater following the start-up instruc-
pletely drain the heater before the first frost. tions in this manual (see Section 7.2).
5. After all water has drained from the heater, 8.3 Inspection and Service
check for mineral buildup in the openings. Jandy Pool Products, Inc. designs and constructs
the XL-3 heater to provide long performance life when
6. Use compressed air to blow out any standing installed and operated properly under normal
water remaining in the heat exchanger. conditions. Periodic inspections, especially at spring
7. Grease the threads on both drain plugs and ports start-up, are important to keep your heater running
and place the drain plugs in a safe place for the safely and efficiently through the years.
winter. Do not reinstall the drain plugs until the
heater is to be started again. WARNING
8. Remove the siphon loop cover from the right side Improper installation or maintenance can cause
of the heater. nausea or asphyxiation from carbon monoxide in flue
gases which could result in severe injury, or death.
9. Remove the compression nut attaching the siphon
loop tube to the pressure switch near the front of 8.3.1 Owner Inspection and Maintenance
the heater. Jandy Pool Products, Inc. recommends that you
inspect the heater on a continual basis and especially
10. Allow the siphon loop to drain. after abnormal weather conditions. The following basic
guidelines are suggested for your inspection:
NOTE: The XL-3 heater is not designed for
continuous use to combat freezing temperatures. Keep 1. Keep the top and surrounding area of the heater
the temperature at a minimum 70°F (21°C) or shut the clear of all debris.
heater down completely.
2. Keep the area around and beneath the heater
Operating the heater for long periods at or near clean and free of all combustible materials such
as paper, leaves, etc.
freezing water temperature can seriously damage the
heater, and may create a dangerous condition by 3. Do not store or use gasoline or other flammable
fouling the external heat exchanger passages, causing vapors, liquids or chemicals in the vicinity of this
incomplete combustion. Even with water flowing or any other appliance.
through the system, ice may build up in the pipes,
restricting the flow of the water to the heater and 4. Do not use this heater if any part has been under
damaging the heat exchanger. water. Immediately call a qualified service
technician to inspect the heater and replace any
8.2.3 Spring Start-up part of the control system, firebox and any fuel
To restart the heater in the spring, have a control which has been under water.
qualified professional technician reassemble the heater 5. If the heater is equipped with a pressure relief
as follows: valve, check for corrosion in and around the
valve. Twice a year, with the filter pump on, lift
1. Fill the siphon loop with approximately 5cc of the release lever on the top of the valve to make
SAE 50, non-detergent oil. Attach the copper sure that water runs freely through it. If corro-
tubing to the pressure switch. sion is found, replace the pressure relief valve.
When replacing the valve, be sure that the pump
2. Install the drain plugs in the ports on both head- is off. Install the valve so that the discharge is
ers. directed away from any area that may be
damaged by water.
3. Make sure that power is supplied to the pump.
Turn on the filter pump and circulate water 6. Be sure all combustion air and ventilation open-
through the heater for 5 minutes. Check for leaks ings are not blocked. Check for spider webs and
while circulating. other debris in the air band, end air shutter and in
the exhaust outlet– especially after a long period
4. Turn on the main fuel supply to the heater at the of nonuse.
shut off valve near the storage tank.
7. Visually inspect the firebox for damage and
deterioration.
Page 22
NOTE: Keep this manual in a safe place for 12. Clean the heat exchanger using the following
future reference by you and your professional schedule:
technician when inspecting and servicing the heater.
After installation and first start-up, check the
heat exchanger for black carbon soot buildup
8.3.2 Professional Inspection and after the following periods of operation: 24 hours,
Maintenance 7 days, 30 days, 90 days and once every 6
Inspections performed at least once a year by a months thereafter, preferably at the end of the
qualified technician are required to maintain your swimming season.
heater's safe and efficient operation. The following
basic safety checks must be performed. Caution
Black carbon soot on a dirty heat exchanger can,
1. Check for loose or broken wires and terminal
under certain circumstances, be ignited by a random
connections.
spark or open flame. To prevent this from happening,
2. Make sure that the pressure switch operates dampen the soot deposits with a wet brush or fine
properly by shutting the filter pump off and on a water spray before servicing or cleaning the heat
few times. The burner should go off immediately exchanger.
after the pump stops. An ignition sequence
should start shortly after the pump is turned back Caution
on. Be careful to avoid damaging the firebox material
when cleaning the heat exchanger or inspecting the
3. Inspect the electrical controls, specifically the heater. Keep water out of the firebox. Be sure to
following: replace the gasket, inspection plug and retainer when
the cleaning or inspection is complete.
a. High limit controls.
b. Water pressure switch.
c. Fuel burner operation. Clean the heat exchanger as follows:
d. Temperature control. a. Remove the heater top assembly and flue
e. Control circuit fuse. collector.
f. Ignition control.
g. Cad cell. b. Remove the inspection hole cover (see Fig. 15).
c. Remove the “V’ baffles (the retaining wire does
not have to be replaced)
4. Inspect the venting system for blockage, leakage,
and corrosion. d. Use an ordinary kitchen brush to brush across
the top of the heat exchanger between the tube
5. Replace the in-line oil filter cartridge once a year. fins.
6. Check for spider webs or other obstructions in e. Use a bottle brush to brush down between the
the air shutters and bands – especially at Spring tube fins toward the firebox.
start-up. Clean with wire brush if necessary. The ash can be softened for easier removal by
7. Conduct a normal operating cycle and observe lightly dampening with a wet brush. Do not let water
that the sequence proceeds as intended. get in the firebox. DO NOT use a water hose to clean
the heat exchanger while it is still installed in the
8. If the heater is equipped with a pressure relief heater. Water will damage the firebox material.
valve, clean any accumulated corrosion and f. Reach through the inspection hole and brush
make sure that water runs freely. across the bottom of the tube fins using the
9. Inspect the inside of the firebox and burner for kitchen brush.
deterioration and indication of improper opera- g. Carefully remove all dirt and soot from the
tion. firebox by inserting a vacuum cleaner nozzle
through the inspection hole.
10. Perform a temperature rise test in accordance
with Section 7.7 of this manual. h. Replace the flue collector and top assembly.
11. Regularly inspect electrical controls for deteriora- For more thorough cleaning, remove the heat
tion. Repair and replace as necessary. exchanger completely and wash it with a garden hose.
Model DP Oil-Fired Heater Page 23
13. Replace the oil nozzle once each season (see the 9.1.4 Pool Water Overheating
oil burner manual). Turn the heater switch OFF and call a service
technician.
14. Oil the burner motor every three months. Use
non- detergent #40 motor oil at both oil holes.
9.2 Professional Troubleshooting Guide
9.2.1 Introduction
SECTION 9. A qualified oil burner technician must service this
equipment. Frequently, this service is available through
Troubleshooting the fuel oil supplier.
9.1 Home Owner Heater Troubleshooting
Problems which may come up with the pool WARNING
heater operation or performance will require a trained, Some of these procedures involve exposing the line
professional technician. There are a few preliminary voltage circuit. There is considerable danger of
symptoms the pool owner should check before calling electric shock.
a technician:
9.1.1 Oil Burner Does Not Fire The XL-3 is an oil-fired pool heater designed to
1. Is the pool temperature control set high enough to burn No. 2 fuel oil or No. 2 diesel fuel. Do not use
call for heat? other fuels. The burner assembly comes standard with
a two-stage pump. This allows the heater to be
2. Is the pool heater switch ON? Are all circuit installed a relatively long distance from the fuel tank.
fuses and remote switches ON?
9.2.2 Initial Checks
3. Is the pool filter clean?
4. Is there enough fuel in the tank? Is the fuel valve 1. Is the oil burner connected to a one- or two-pipe
turned ON? system? All units are factory set for one-pipe
systems. To convert a unit to a two-pipe system,
If the answer to all of these questions is yes, try a bypass plug must be installed in the fuel pump.
the manual overload reset switches on the burner The plug is supplied with the oil burner. There is
motor and primary control. If burner does not fire, turn a decal located on the fuel pump showing where
the heater switch OFF then ON, and try the reset the bypass plug goes.
switches again. If the burner still refuses to fire, call
the service technician. If a fuel unit is set up for a two-pipe system, but
is actually connected to a one-pipe system, the
pressure in the fuel pump builds up to over 300
9.1.2 Heater Does Not Maintain the Desired psi when the burner turns on. This will cause the
Water Temperature motor to bind and stop running or ruin the pump
1. Is the temperature control set high enough? seals, or both.
2. Is the filter cycle setting on the time clock long 2. An oil filter must be installed on the inlet line. A
enough to permit the heater to raise the very small amount of dirt in the oil can plug the
temperature? nozzle. A properly sized oil filter is shipped with
the heater (see Figure 8).
3. Is the heater the right size for the pool?
3. Is there oil in the storage tank?
4. Are all of the shut-off valves on the oil lines
If these conditions are satisfactory, the heat open?
exchanger could be fouled, or the heater controls may
not be functioning properly. Call a service technician. 5. Are the fuel lines adequately sized according to
the Table 3 on page 10?
9.2.3 Troubleshooting
NOTE: These troubleshooting procedures
require connections to electrical terminals and jumper
wires to check operation. To avoid electrical shock,
turn off electric power before servicing line voltage
controls. Never leave a jumper wire in place to fix a Figure 21. Cad Cell and Primary Control.
heater. This would bypass safety and operating
controls. See Figure 21 for burner parts identification. 5. Remove one cad cell wire from the primary
control. If the burner starts, replace the cad cell.
9.2.3.1 Burner will not start (motor and
6. Turn off electric power to the heater. Short out
transformer do not come on) the high limit switch, in the high voltage circuit. If
1. Is there power to the heater? Have you checked the burner starts when power is restored, the
the reset buttons on the motor and primary switch is faulty.
control? 7. Turn off electric power and inspect the wiring
2. Place a jumper wire across the two terminals on below the primary control and the ignition
the cad cell. If the burner starts, the problem is in transformer. Make sure there are no loose
the heater control circuit. This circuit consists of connections.
the pressure switch, high limit control, safety 8. If the wiring is okay, and the blower wheel
switch, thermostat, time clock switch (if one is rotates freely, replace the primary control.
installed) or the wire harness. Check the wire
harness for any loose wires or worn insulation. 9.2.3.2 Burner Tries to Start, but the
Then jumper each control until the problem is
Primary Control Shuts Off
located.
(either motor or transformer or
3. Press the reset button on the primary control. If both come on)
the unit does not start, go to step 5. If the unit
starts, turn off the power and check the following 1. Is the burner motor turning? If yes, go to next
items that can lock out the primary control: step.
2. Press the reset buttons on the motor and primary
a. Dirty or defective cad cell. control. If the motor does not start, but
b. Defective primary control. transformer is providing spark at the electrodes,
c. Oil level in tank too low or water in the go to step 3.
tank. 3. Lift the ignition transformer and make sure the
d. Poor combustion caused by: motor rotates freely. If it does not rotate freely,
Fouled nozzle replace the motor. If the motor is internally
Fuel line air leaks binding, replace the motor.
Improper nozzle pressure (pressure
should be 100 psi) 4. Open the inspection port and use a mirror to
Improper air setting (see Section check combustion. If there is no ignition before
9.2.3.4) the primary control shuts the burner down, go to
step 6. If the burner does ignite with a good
4. Press the reset button on the motor. If the unit flame, go to step 5. If the burner tries to ignite,
does not start, go to step 5. If the unit starts, shut but the flame is intermittent, go to step 8.
off power and check the blower wheel and
flexible coupling between the motor and the fuel 5. Check the cad cell and primary control.
pump. Make sure the blower wheel and fuel unit
are not binding. Make sure the return fuel line is
not restricted.
Model DP Oil-Fired Heater Page 25
6. Lift up the ignition transformer and put tape over pressure switch, high limit safety switch, thermostat
the front of the cad cell (the burner will not start and wire harness. Check for worn insulation on the
unless the cad cell senses no light). Disconnect wire harness, which could cause a short. Check
the black lead going to the motor. Press the operation of the thermostat and pressure switch.
primary control reset button. Use an insulated
screwdriver to touch the metal blade to one 9.2.3.4 Setting the Correct Fuel-Air
spring contact on the transformer, and about 3/8" Mixture
away from the other spring contact. If there is Measure the C02. If it measures less than 11.5%,
good spark between the blade and the spring, go decrease the air supply. If it measures higher than
to the next step. If there is no spark, replace the 12.5%, increase the air supply.
transformer. When the fuel-air setting is correct, there will be
7. Remove the electrode-nozzle assembly and zero smoke. If there are still traces of smoke after
inspect the high voltage sections for fouling, adjusting the fuel-air mixture, slowly increase the air
cracked insulators or burnt electrodes. Replace supply until the smoke disappears.
any defective parts. Use the proper instruments to measure both the
smoke and C02.
8. If the flame is poor quality or intermittent, use a
pressure gauge to check the nozzle pressure. If 1. Too Much Air (low C02)
the pressure is below 100 psi, but steady, reset it Too much air decreases the efficiency of the
to 100 psi and go to step 9. If the pressure is not heater, and causes overheating of the jacket by
steady, use the attached Sundstrand Field Service pressurizing the firebox. Too much air can also
bulletin to check out the fuel unit. An unsteady cause poor ignition and a pulsating flame. If the
pressure reading could be a sign of a dirty oil C02 reading is below 11.5%, reduce the air
filter. adjustment openings on the burner.
9. Replace the burner nozzle with the nozzle called 2. Not Enough Air (high C02)
out on the heater rating plate and go to step 10.
Replace nozzles once a year as part of the Not enough air is much easier to detect. The
annual cleaning and inspection service. flame is dark yellow and the heater will smoke.
Generally, the C02 reading will be above 12 %
10. Check the C02 Of the flue gases. The reading when not enough air is provided.
should be between 11.5 to 12.5%. If the reading
is different, go to Section 9.2.3.4. Lacking proper instruments, a temporary fuel-air
adjustment can be made. Close the end shutter
9.2.3.3 Oil Burner Will Not Shut Off and then slowly close the air bank until the heater
Remove one of the thermostat leads from the starts to smoke. Slowly open the end shutter until
primary control. If the oil burner shuts off, the problem the smoke completely disappears. The fuel-air
is in the heater control circuit. The circuit includes the mixture will be close to the correct setting.
OPTIONAL EQUIPMENT
80 Pressure Relief Valve, 3/4" NPT, 75 PSI All R0040400
81 Chimney Cap - 9" All R0393800
Page 28
81
53
54
55
51
56
57
52
34 7
7
26 25 5
35 6
29 7
22 27 14
12
25 15
30 80
33
23 37
34 35 40 36
28 33 30 38
13
29 27
60 16
59
23
45 43
47 58 42
44 41
49 50
48
32
46 4
3
9
14
19
10
21
1 17
20
8
Model DP Oil-Fired Heater Page 29
NOTES
Jandy® and XL-3® are registered trademarks of Jandy Pool Products, Inc. All other brand names, products
names or trademarks belong to their respective holders.
LIMITED WARRANTY
Thank you for purchasing Jandy® pool and spa products. Jandy Pool Products, Inc. warrants all parts to be free
from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase,
with the following exceptions:
• AquaLink® RS units installed with Jandy Surge Protection Kits will be covered for two years.
• NeverLube® valves are warranted for the life of pool and/or spa on which they were originally installed.
This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have
been moved from their original installation sites. The liability of Jandy Pool Products, Inc. shall not exceed the repair
or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective part,
transportation to or from the factory, and any other materials required to make the repair. This warranty does not
cover failures or malfunctions resulting from the following:
1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation,
Operation and Maintenance Manuals provided with the product(s).
2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total
Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000].
4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing
sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.
9. Overheating, incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-
Rings, DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities
of water.
LIMITATION OF LIABILITY:
This is the only warranty given by Jandy Pool Products, Inc. No one is authorized to make any other warranties
on Jandy Pool Products, Inc.'s behalf. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS
FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. JANDY POOL PRODUCTS, INC. EXPRESSLY
DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT OR PUNITIVE
DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY. This warranty gives you specific
legal rights. You may also have other rights which vary by state or province.
WARRANTY CLAIMS:
For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase,
model number, serial number and date of installation. The installer will contact the factory for instructions regarding
the claim and to determine the location of the nearest designated service center. If the dealer is not available, you
can locate a service center in your area by visiting www.jandy.com or by calling our technical support department
at (707) 776-8200 extension 260. All returned parts must have a Returned Material Authorization number to be
evaluated under the terms of this warranty.
H0223500C