You are on page 1of 3

HAZ

No Item Function/ Parameter Guide Word


Purpose
1 pump Temperature More

2 pump Fluid More

3 pump pressure low

high
HAZOP ANALYSIS
Consequence Cause

blowning pump reduce capacity in pump 1.too much fluid quantity and too much pump work
2.low flow

system leaks poorly packed valves

vacuum operating conditions were not reached condenser work is not optimal

pump will run at a higher capacity pump rpm is too high