You are on page 1of 5

RTN-905.

2A/RTN-950A/RTN-980 ALARMS
Alarm Name Description Probable Causes Remarks
AU_AIS The AU_AIS is an alarm The opposite NE inserts the AU_AIS Major
indicating the alarm.The transmit unit of the
administrative unit (AU). opposite NE is faulty.The receive
This alarm occurs when unit of the local NE is faulty.
the board detects the AU
pointer of all 1s for three
consecutive frames

BD_NOT_INSTALLED The BD_NOT_INSTALLED The logical board is not added in the Minor
is an alarm indicating that corresponding logical slot.
the physical board is
installed in a certain slot,
but the logical board is not
added.

BD_STATUS The BD_STATUS is an If the alarm is reported by a board of Major


alarm indicating that the the IDU, the possible causes are as
board cannot be detected. follows: Cause 1 of the alarm
reported by a board of the IDU: The
board is installed in an incorrect slot.
Cause 2 of the alarm reported by a
board of the IDU: The board and the
backplane are not connected
properly. Cause 3 of the alarm
reported by a board of the IDU: The
slot is faulty. Cause 4 of the alarm
reported by a board of the IDU: A
certain board is faulty. If the alarm is
reported by the ODU, the possible
causes are as follows: Cause 1 of
the alarm reported by the ODU: The
other alarms are generated. Cause
2 of the alarm reported by the ODU:
The ODU is faulty.
RTN-905.2A/RTN-950A/RTN-980 ALARMS
Alarm Name Description Probable Causes Remarks
CONFIG_NOSU Configuration not The type of the ODU mismatches Major
supported to ODU the configured parameters.
PPORT

E1_LOS 2M line loss of signal The input E1 signal is abnormal.The Minor


tributary board of the local station is
faulty.

FAN_FAIL The FAN_FAIL alarm The board is faulty.The board and Major
indicates "fan failed". the backplane are poorly connected.

HARD_BAD The HARD_BAD alarm The board is faulty. The board and Critical
indicates "hardware error". the backplane are poorly
connected.The slot is faulty.

IF_INPWR_ABN The IF_INPWR_ABN There is an inloop operation on the Major


alarm indicates "abnormal IF port.The IF boards are faulty.The
input IF power of the IF cables are faulty.The ODU is
ODU". faulty.

LTI The LTI alarm indicates The clock configuration is incorrect. Major
"loss of timing input". The clock sources in the clock
When all the synchronous source priority table fail.
sources are lost for the
NE, this alarm is reported.

ETH_LOS Ethernet loss of signal. The Ethernet/Optical port is enable Critical


but open
MW_LOF The MW_LOF alarm The MW link performance degrades. Critical
indicates "loss of RS The transmit unit the opposite
frame". station is faulty.The receive unit of
local station is faulty.
RTN-905.2A/RTN-950A/RTN-980 ALARMS
Alarm Name Description Probable Causes Remarks
POWER_ALM The POWER_ALM alarm The input power is abnormal. Major
indicates "power module
alarm". The power module is abnormal.

POWER_FAIL The POWER_FAIL alarm The ODU is faulty. Major


indicates "power failure".
When the ODU detects the
ODU power module failure,
this alarm is reported.

RADIO_RSL_HIGH The RADIO_RSL_HIGH The ODU is faulty. There is a strong Critical


alarm indicates "radio interference source nearby.
receive signal level too
high". When the receive
power is detected higher
than the upper threshold of
the ODU receive power (-
20 dBm), this alarm is
reported.

RADIO_RSL_LOW The RADIO_RSL_LOW The microwave link signal is too Critical


alarm indicates "radio much attenuated. The transmit
receive signal level too power of the opposite station is too
low". When the receive low.The ODU of the local station is
power is detected below faulty.
the lower threshold of the
ODU receive power
(-90 dBm), this alarm is
reported.

RADIO_TSL_HIGH The RADIO_TSL_HIGH The ODU is faulty. Critical


alarm indicates "radio
transmission signal level
too high". When the
transmit power is detected
higher than the upper
power threshold of the
ODU, this alarm reported.

RTN-905.2A/RTN-950A/RTN-980 ALARMS
Alarm Name Description Probable Causes Remarks
RADIO_TSL_LOW The RADIO_TSL_LOW The ODU is faulty. Critical
alarm indicates "radio
transmission signal level
too low". When the receive
power is detected below
the lower power threshold
of the ODU, this alarm is
reported.
T_ALOS The T_ALOS alarm The port does not access the 2 Major
indicates "E1 interface loss Mbit/s service.The opposite
of analog signal". equipment is faulty.The trunk cable
is faulty.The board that reports the
alarm is faulty.

T_LOS The T_LOS alarm The SDH service configuration Major


indicates "transmit loss of mismatches the type of the line
signal". board.The cross-connect and timing
board is faulty.The line board is
faulty.

TEMP_ALARM The TEMP_ALARM alarm The board temperature exceeds the Minor
indicates "temperature threshold.The temperature detecting
over threshold". circuit is faulty.

TU_AIS The TU_AIS alarm The data configuration is wrong.The Major


indicates "TU alarm line is faulty.The cross-connect and
indication". timing board is faulty.The tributary
board is faulty.

VOLT_LOS The VOLT_LOS alarm The input power is abnormal. Major


indicates "loss of voltage". The power module is normal.
The power switch is not turned on.

CLK_TRACE_NO_MOD Clock alarm. If physical clock not setup Major/Minor

UP_E1_AIS The UP_E1_AIS alarm The opposite equipment sends the Minor
indicates "2M up signal E1_AIS signal.The receive unit of
alarm indication". the tributary board of the local
station is faulty.

RTN-905.2A/RTN-950A/RTN-980 ALARMS

Alarm Name Description Probable Causes Remarks


IN_PWR_ABN The IN_PWR_ABN is an The transmit power of the opposite Major
alarm indicating that the NE is over high or over low.The
input optical power is model of the selected optical module
abnormal. is incorrect.The optical module at
the receive end is faulty.The fiber
performance degrades.