7SR10 – Argus

Overcurrent and Earth Fault Protection

siemens.com/reyrolle

Description
The Reyrolle 7SR10 Argus overcurrent and earth fault relay is
a numerical overcurrent protection relay intended as a
simple protection solution for distribution and industrial
applications. The relay is developed using the latest
generation of hardware technology and is available in
multiple variants depending on power supply, Binary input/
binary output configuration and data communication
facility.

Main Function Feeder protection for distribution and industrial


networks

Inputs and Outputs 4 Current Transformers with 1A and 5A


Inputs, 3 or 6 Binary Inputs and 3 or 6 Binary
Outputs

Communication Front USB, Rear RS485 port (optional) for remote


connection

Housing Size 4, 4U high - non draw-out case

Benefits Applications
• Circuit breaker open and close fascia push button • Feeder overcurrent protection
• Protection settings can be viewed and edited from the • Backup protection
fascia • Compact substation
• 9 users programmable LEDs • Protection against harmonic injection into grid by non
• Cold load protection conventional sources of energy
• Two setting groups • Focused on renewable energy sources
• Password protection - 2 levels • Industry medium voltage and low voltage applications
• User programmable logic aided by 8 virtual inputs /
outputs
• Self Monitoring
• Circuit breaker trip and maintenance counter
• The last 15 fault records are displayed on the relay fascia
• Waveform recorder stores 15 records (1 second
duration)


Protecting your electrical assets... today and tomorrow

Protection functions Reydisp software


• 46BC Broken Conductor, Load Unbalance • In addition to being fully programmable via the relay’s
• 46NPS Negative Phase Sequence Overcurrent fascia keys, the 7SR10 utilises the free of charge Reydisp
• 49 Thermal Overload Evolution setting software package. This software
• 50 Instantaneous Overcurrent Protection supports setting, data and waveform analysis and
• 50N/G Instantaneous Earth Fault commissioning aids.
• 51 Time Delayed Overcurrent Protection
• 51N/G Time Delayed Derived / Measured Earth Fault
Protection
• 51C Cold Load Pickup
• 50BF Circuit Breaker Fail
• 51SEF Time Delayed Sensitive Earth Fault Protection
• 81HBL2 Inrush Restraint
• 50SEF Instantaneous Sensitive Earth Fault

Supervision Functions
• Trip Circuit Supervision (74TC)
• Total Harmonic Distribution Supervision (81THD)

Control Functions
• 86 Lockout
• CB Control
• 79 Optional Auto Reclose

Subject to changes and errors


Siemens Protection For enquires please contact our The information given in this
Devices Limited Customer Support Center document only contains
general descriptions and / or
North Farm Road Phone: +49 180/524 8437 (24hrs) performance features which
Hebburn Fax: +49 180/524 24 71 may not always specifically
Tyne & Wear E-mail: support.ic@siemens.com reflect those described or which
NE31 1TZ www.siemens.com/protection may undergo modification in
United Kingdom the course of further
development of the products.
Article No. EMEA-B10053-00-76GB
The requested performance
Printed in the UK
features are binding only when
they are expressly agreed upon
in the concluded contract.

You might also like