Professional Documents
Culture Documents
Requerimiento de Claridad Roof Safe Cable
Requerimiento de Claridad Roof Safe Cable
D D D D
C Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Span Length Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection
(m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m)
5 5.8 5 1 0.49 6.2 5 1.3 0.51 6.3 5.25 1.5 0.53 6.7 5.5 1.6 0.63
10 6.4 5 1.6 0.54 6.9 5 2.1 0.7 7.4 5.25 2.3 0.77 7.5 5.5 2.4 0.84
15 6.4 5 1.7 0.54 7.2 5.5 2.4 0.72 7.8 6 2.8 0.93 8.3 6 2.9 1.04
D D D D
C Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Span Length Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection
(m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m)
5 6 5.5 1.2 0.49 6.5 5.5 1.5 0.58 6.7 5.5 1.6 0.64 6.8 5.5 1.7 0.67
10 6.6 5.5 1.8 0.61 7.2 5.5 2.2 0.7 7.6 5.5 2.6 0.86 7.8 5.5 2.7 0.96
15 6.8 6 2.2 0.66 7.7 6 2.8 0.96 8.1 6 3.1 1.02 8.6 6 3.3 1.14
D D D D
C Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Span Length Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection
(m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m)
5 5.9 6.5 1.2 0.55 6.3 6.5 1.5 0.73 6.6 6.5 1.7 0.82 6.9 6.5 1.9 0.87
10 6.4 6.5 1.6 0.63 7.1 6.5 2 0.83 7.5 6.5 2.3 0.95 7.6 7 2.4 1.1
15 6.8 6.5 2 0.79 7.3 7 2.8 1.11 8.1 7 3 1.27 8.5 7 3.3 1.38
D D D D
C Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Clearance
Required Peak End Peak HLL
Combined
Post
Span Length Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection Below the Anchor Load Deflection Deflection
(m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m) HLL - (m) (kN) (m) (m)
5 6.1 6.5 1.4 0.66 6.6 6.5 1.6 0.74 6.8 6.5 1.8 0.83 7.1 6.5 1.9 0.92
10 6.5 6.5 1.8 0.76 7.3 6.5 2.3 0.96 7.7 6.5 2.5 1.1 7.9 7 2.7 1.2
15 6.9 6.5 2.1 0.8 7.4 7.3 2.8 1.15 8.2 7.3 3 1.3 8.8 7.5 3.3 1.4
Assumptions:
• 1:1 Test Mass
• Sequential Fall Procedure
• Test performed on a Single Span System with End Post at both ends.
• 100 kg tests done with CE Lanyard. 141 kg tests done with EZ-Stop Lanyard.
• Clearance Calculation include 1.5 m D-Ring Height, 0.3 m Harness Stretch, 1 m Clearance Margin
Fall Clearance