1. OUTLINE
Micro computer based electro-hydraulic pump and engine mutual control system (mode selection
system) optimizes the engine and pump performance.
The combination of 4 power modes(H,S,L,F) makes it possible to use the engine and pump power
more effectively corresponding to the work conditions from a heavy and great power requesting work
to a light and precise work.
Engine rpm
Item Mode Application
Idle rpm Rated rpm
H Heavy duty operation 2150+50 2000
POWER S General operation 2150+50 2000
MODE L Light duty operation 1950+50 1800
F Finishing operation 1650+50 1500
TRAVEL LO Low speed travelling ӧ ӧ
MODE HI High speed travelling ӧ ӧ
KEY STARTING ӧ Key switch start position 800Ţ100 ӧ
AUTO DECEL MODE ӧ Engine deceleration 1200Ţ100 ӧ
When engine start, S mode, Auto Decel and Travel Lo(Turtle) mode are selected automatically.
5-3
2. PUMP CONTROL BY ENGINE SPEED SENSING
If any engine speed drops under the reference şEngine Torque
rpm of each mode set caused by the pump
load are detected by the engine speed sensor,
Engine torque T
H
CPU controller sends calculated current signal
F L S
to EPPR(Electro Proportional Pressure
Reducing) valve to match engine torque with
pump torque optimally by controlling the pump
discharge volume.
şH : Heavy duty operation mode
şS : General operation mode Engine speed N
şL : Lifting operation mode
şF : Finishing operation mode
şEngine horsepower
Engine horswpower HP S
L
Engine speed N
L
Pump discharge volume Q
H
S
5-4
3. MAXIMUM POWER OF H MODE şEngine Torque
Engine torque T
CPU controller moves the engine governor
motor to set the throttle lever to the full
position and sends initial current signal to
the EPPR valve to set the pump absorption
torque high. So, it is possible to maximize
the work performance by using 100$ of the
engine power at this mode.
Engine speed N
2) If the pump load becomes too high and the
engine speed drops, the CPU controller
reduces the pump discharge amount and şEngine horsepower
momentarily resets the engine speed to the
rated point through engine speed sensing.
Engine horsepower HP
Engine speed N
5-5
4. GENERAL STANDARD POWER OF S MODE şEngine Torque
Engine torque T
CPU controller moves the engine governor
motor to set the throttle lever to the full
position and sends power shift current to
EPPR valve which reduces the pump
discharge. So the pump absorption
horsepower is reduced by 15$.
2) Engine speed sensing at the matching point
Engine speed N
is the same as for H mode.
şEngine horsepower
Engine speed N
5-6
5. ENERGY SAVING AND LIGHT POWER OF şEngine Torque
L MODE
Engine t torque T
1) When L mode is selected in the cluster,
CPU controller moves the engine governor
motor to set the throttle lever to the partial
position and it sends large amount of power
shift current to EPPR valve, which reduces
the pump absorption horsepower 30$-
So, at the this mode it is useful for light work
and energy saving. Engine speed N
Engine speed N
5-7
6. FINISHING WORK OF F MODE şEngine Torque
Engine torque T
CPU controller moves the engine governor
motor to set the throttle lever to the partial
position and it sends of power shift current
to EPPR valve to reduces the pump
absorption horsepower to the least amount
as much as 50$of full horsepower. So, at
this mode it is useful light work, especially
for finishing work. Engine speed N
Engine speed N
5-8
Power boost switch OFF Power boost switch ON Other functions
Mode
Power Level of Power Level of Auto Overheat
set achievement set achievement decel prevention
T
250HP/
H ON / OFF ON
2000rpm N
Q N
P
250HP/
2000rpm P
şPower shift by eppr valve.
S 213HP/
ON / OFF ON
2000rpm N
Q
L 175HP/
ON / OFF ON
1800rpm
N
F 125HP/
ON / OFF ON
1500rpm
N
5-9