You are on page 1of 4

Pump size & type : PHL 35.10.08.

25F
Based on curve no. : 50
Number of stages : 1

Customer : Ydeasteam SAS Capacity : 530.0 USgpm


Item number : PTO Head : 408.00 ft
Service : Specific gravity : 0.804
Vendor reference : Default 1.1 Pump speed : 3550 rpm
Date : June 13, 2011
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS, CAPACITY, HEAD, AND EFFICIENCY.

Copyright © 2009 Flowserve. All rights reserved. FlowSelex v2.2

1 of 4
Hydraulic Datasheet
Customer : Ydeasteam SAS Pump / Stages : PHL 35.10.08.25F / 1
Customer reference : Default Based on curve no. : 50
Item number : PTO Vendor reference : Default 1.1
Service : Date : June 13, 2011

Operating Conditions Materials / Specification


Capacity : 530.0 USgpm Material column code : S-6
Water capacity (CQ=1.00) : 530.0 USgpm Pump specification : -
Normal capacity : - Other Requirements
Total Developed Head : 408.00 ft
Hydraulic selection : API-610 8th Edition
Water head (CH=1.00) : 408.00 ft
Construction : API-610 8th Edition
NPSH available (NPSHa) : Ample
Test tolerance : API-610 8th Edition
NPSHa less NPSH margin : -
Driver Sizing : Max Power(MCSF to EOC)with SF
Maximum suction pressure : 400.0 psig **
Performance data based on standard impeller
Liquid Seal configuration : Single Seal
Liquid type : Hydrocarbon
Temperature / SG : 60 F / 0.804
Solid Size - Actual / Limit : - / -
Viscosity / Vapor pressure : 1.2 cSt / -
Performance
Hydraulic power : 43.9 hp Impeller diameter
Pump speed : 3550 rpm Rated : 9.74 in
Efficiency (CE=0.99) : 70.0 % Maximum : 10.24 in
Minimum : 8.27 in
NPSH required (NPSHr) : 18.1 ft Suction specific speed : 7470 US units
Rated power : 62.8 hp Minimum continuous flow : 190.0 USgpm
Maximum power : 86.6 hp Maximum head @ rated dia : 454.41 ft
Driver power : 100.0 hp / 74.6 kW Flow at BEP : 743.4 USgpm
Casing working pressure : 566.1 psig Flow as % of BEP : 71.3 %
(based on shut off + 5% cut dia) Efficiency at normal flow : -
Maximum allowable : 580.2 psig Impeller dia ratio (rated/max) : 95.1 %
Hydrostatic test pressure : 870.2 psig Head rise to shut off : 11.4 %
Est. rated seal chamb. press. : - Total head ratio (rated/max) : 89.0 %

CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS, CAPACITY, HEAD, AND EFFICIENCY.

** denotes rejection criteria

Copyright © 2009 Flowserve. All rights reserved. FlowSelex v2.2


2 of 4
Construction Datasheet

Customer : Ydeasteam SAS Pump / Stages : PHL 35.10.08.25F / 1


Customer reference : Default Based on curve no. : 50
Item number : PTO Vendor reference : Default 1.1
Service : Date : June 13, 2011

Construction Driver Information


Nozzles Size Rating Face Pos'n Manufacturer : -
Suction 4" - - - Power : -
Discharge 3" - - - Service factor (req'st / act) : 1.0 / 0.0
Speed : -
Casing mounting : Center-line
Orientation / Mounting : Horizontal / -
Casing split : Radial
Driver Type : -
Impeller type : Closed
Frame-size / material : - / -
Bearing type (radial) : Ball
Enclosure : -
Bearing number (radial) : -
Hazardous area class : -
Bearing type (thrust) : Ball
Explosion 'T' rating : -
Bearing number (thrust) : -
Volts / Phase / Hz : - / - / -
Bearing lubrication : Flood
Amps-full load/locked rotor : - / -
Rotation (view from cplg) : CCW per Hyd
Motor starting : Direct on line (DOL)
Materials Insulation : -
Casing : - Temperature rise : -
Impeller : - Bearings : -
Case wear ring : - Lubrication : -
Impeller wear ring : - Motor mounted by : -
Inducer : N/A
Sound Pressure (dBA @ 1.0 m)
Shaft : -
Driver, expected : -
Sleeve : See Mechanical Seal
Pump & driver, estimated : -
Baseplate, Coupling and Guard
Seal Information
Baseplate type : -
Arrangement : -
Baseplate material : -
Size : -
Coupling manufacturer : -
Manufacturer / Type : - / -
Coupling size : -
Material code (Man'f/API) : - / -
Coupling / Shaft guard : -
Internal neck bushing : -
Weights (Approx.)
Gland
Bareshaft pump(nett) : 837.8 lb
Gland material : -
Baseplate(nett) : -
Flush : -
Driver(nett) : -
Vent : -
Shipping gross weight/vol. : - / -
Drain : -
Testing Auxiliary seal device : -
Hydrostatic test : - Piping
Performance test : -
Seal flush plan : -
NPSH test : -
Seal flush construction : -
Paint and Package Seal flush material : -
Pump paint : - Aux seal flush plan : -
Base grout surface prep : - Aux seal flush construction : -
Shipment type : - Aux seal flush material : -
Notes
-

Copyright © 2009 Flowserve. All rights reserved. FlowSelex v2.2


3 of 4
Customer : Ydeasteam SAS Pump size & type : PHL 35.10.08.25F
Item Number : PTO Based on curve no. : 50
Service : Number of stages : 1
Vendor Reference : Default 1.1
Date : June 13, 2011 Capacity : 530.0 USgpm Specific gravity : 0.804
Head : 408.00 ft Pump speed : 3550 rpm

Copyright © 2009 Flowserve. All rights reserved. FlowSelex v2.2

4 of 4

You might also like