You are on page 1of 4

Pump size & type / Stages : 2K4x3US-82OP M3US /1

Based on curve no. : MIII8080


Impeller diameter : 6.63 in

Customer : HMV INGENIEROS Capacity : 220.0 USgpm


Item number : Bomba Prodeco Head : 12.15 psi
Service : Prodeco Density / Specific gravity : - / 1.000
Flowserve reference : 1900546465 Pump speed : 1750 rpm
Date : July 26, 2019 Ns / Nss : 1797 / 6780 (US units)
Test tolerance : ANSI/HI 14.6 Grade 1U
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.

Copyright © 2016 Flowserve. All rights reserved. Affinity v2.14.6


Hydraulic Datasheet

Customer : HMV INGENIEROS Pump / Stages : 2K4x3US-82OP M3US /1


Customer reference : Cenit Based on curve no. : MIII8080
Item number : Bomba Prodeco Flowserve reference : 1900546465
Service : Prodeco Date : July 26, 2019
Operating Conditions Materials / Specification
Capacity (rated/normal) : 220.0 USgpm / - Material column code : S/D
Water capacity (CQ=1.00) :- Pump specification : ANSI B73.1
Total developed head : 12.15 psi Other Requirements
Water head (CH=1.00) :- Hydraulic selection : No specification
NPSHa/NPSHa less margin : 20.0 ft / - Construction : No specification
Maximum suction pressure :- Test tolerance : ANSI/HI 14.6 Grade 1U
Liquid Driver Sizing : Rated Power
Liquid type : Other Seal configuration : Single Seal
Liquid description :-
Temperature : 195 °F
Density / Specific gravity : - / 1.000
Solid Size - Actual / Limit : - / 0.5000 in
Viscosity / Vapor pressure : 1.00 cSt / -
Performance
Hydraulic power : 1.56 hp Impeller diameter
Pump speed : 1750 rpm Rated : 6.63 in
Pump overall efficiency (CE=1.00) : 41.6 % Maximum : 8.19 in
NPSH required (NPSH3) : 3.9 ft Minimum : 6.63 in
Rated brake power : 3.75 hp Ns / Nss : 1797 / 6780 (US units)
Minimum continuous flow : 32.3 USgpm
Maximum brake power : 4.19 hp Maximum head at rated diameter : 13.53 psi
Driver power rating : 5.00 hp / 3.73 kW Flow at BEP : 281.7 USgpm
Casing working pressure : 13.5 psig Flow as % of BEP : 78.1 %
(based on shut off @ cut dia/rated SG) Efficiency at normal flow :-
Maximum allowable : 261.3 psig Impeller diameter ratio (rated/max) : 80.9 %
Hydrostatic test pressure : 428.0 psig Head rise to shut off : 11.3 %
Estimated rated seal chamber pressure :- Total head ratio (rated / max) / (max / rated) : 51.5 % / 194.2 %
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.

Copyright © 2016 Flowserve. All rights reserved. Affinity v2.14.6


Construction Datasheet

Customer : HMV INGENIEROS Pump / Stages : 2K4x3US-82OP M3US /1


Customer reference : Cenit Based on curve no. : MIII8080
Item number : Bomba Prodeco Flowserve reference : 1900546465
Service : Prodeco Date : July 26, 2019
Construction Driver Information
Nozzles Size Rating Face Position Manufacturer : Flowserve Choice
Suction 4.00 150# FF End Power : 5.00 hp / 3.73 kW
Discharge 3.00 150# FF Top Service factor (requested / actual) : 1.15 / 1.25
Casing mounting : Foot Synchronous speed : 1800 rpm
Casing split : Radial Orientation / Mounting : Horizontal / Foot
Impeller type : Open Vane Driver type : NEMA
Bearing type (radial) : Single row Frame-size / material : 184T / Aluminum
Bearing number (radial) : 6310-C3 Enclosure :-
Bearing type (thrust) : Double row Hazardous area class : N/A Safe Area
Bearing number (thrust) : 5310-AHC3 Explosion 'T' rating : N/A Safe Area
Bearing lubrication : Flood Volts / Phase / Hz : 230 / 3 / 60 Hz
Rotation (view from driver) : CW per Hyd. Institute Amps-full load/locked rotor : 6.30 A / 45.00 A
Materials Motor starting : Direct on line (DOL)
Casing : DS/WCB Insulation :F
Impeller : Ductile Iron (DCI) Temperature rise : 80 °C
Seal chamber : FML Box / (DCI) Bearings : Ball
Shaft : BB 1144 Steel Lubrication : Grease
Sleeve : No Sleeve Req'd Motor mounted by : FPD
Baseplate, Coupling and Guard Sound Pressure (dBA @ 1.0 m)
Baseplate type : A Foundation Driver, expected : 60.0 dBA
Baseplate material : Steel Pump & driver, estimated : 66.0 dBA
Baseplate size : 245 Seal Information
Coupling manufacturer : Rexnord Arrangement : Sgl Int O-Ring
Coupling size : Omega ES3-R Size : 1.875 Inch
Coupling / Shaft guard : Aluminum Manufacturer / Type : Flowserve / ISC2 Pusher
Shaft / seal guard : None Provided Material code (Man'f/API) : C2CPX----ECXV- / SBTFN
Weights (Approx.) Internal neck bushing : Not Available
Bareshaft pump (net) : 400.0 lb Gland
Baseplate (net) : 129.0 lb Gland material : 316SS Large Bore
Driver (net) : 70.1 lb Flush : .375" NPT
Shipping gross weight/volume : 689.0 lb / 19678 cu.in Vent : .25" NPT
Testing Drain : .25" NPT
Hydrostatic test : Non witnessed Auxiliary seal device : Carbon Bushing
Performance test : None Piping
NPSH test : None Seal flush plan : Other
Paint and Package Seal flush construction : Hose
Pump paint : FLS St'd PU Topcoat Seal flush material : Other
Base grout surface prep : Flowserve St'd D14-3 Aux seal flush plan : None
Shipment type : Domestic Aux seal flush construction :-
Aux seal flush material :-
Notes
-

ANSI 3A Power End

Casing w/1/2" Plugged Drain (NPT)

No cust. insp. or documents required

Copyright © 2016 Flowserve. All rights reserved. Affinity v2.14.6


Full Page GA Drawing

-
Customer : HMV INGENIEROS Pump size & type : 2K4x3US-82OP M3US Drawing number :-
Item number : Bomba Prodeco Pump speed / Stages : 1750 rpm / 1 Date : July 26, 2019
Service : Prodeco Flow / Head : 220.0 USgpm / 12.15 psi Certified by / Date : :-
Customer PO # :- Driver power / Frame : 5.00 hp / 3.73 kW / 184T Seal type : ISC2 Pusher
Flowserve reference : 1900546465 Volts / Phase / Hz : 230 / 3 / 60 Hz Seal flush plan : Other

Copyright © 2016 Flowserve. All rights reserved. Affinity v2.14.6

You might also like