You are on page 1of 5

Electromechanical MV-94134B

Revised 07-99

Fuel Shutoff Valves


Catalog Section 55
(00-02-0124)

M25 and M50 Series


■ Instant Response to Shut Off Signal
■ Positive Valve Closure

■ Vents Gases Trapped After Shutdown

■ Explosion-proof Models Available

■ Models Available for Magneto,

CD Ignition or 12/24 VDC


Model M5081 ■ Normally Energized Model Available

Description Specifications Options and Accessories


These fuel shutoff valves are semi-automatic Valve Body: Sandcast aluminum, painted Diode Package (65010065)
devices for shutdown of natural gas fueled red (corrosion resistance). Optional cast The Murphy 202 V diode package is designed to
engines. The valve is opened manually and closes steel available for M5081 and M5081FS allow the fuel shutoff valve to be used with dual
when the electromagnet is energized and trips the models only. Magneto Ignition systems. Sold separately (see
latch. The valve can be closed manually by turning Valve Seat: Buna-N How to Order).
the valve’s disconnect knob. A normally energized Magnetic Switch Adapter
Maximum Pressure Rating:
model is available that holds the valve open elec- As ignition systems wear from usage their power
• M2582: 80 psig (552 kPa) [5.52 bar]
trically and closes when the coil is de-energized. A output becomes less and less. Ignition may not
• M5081: 100 psig (689 kPa) [6.89 bar]
vent in the valve body relieves trapped gas when have the capacity to reliably trip the fuel valve.
• M5081FS: 100 psig (689 kPa) [6.89 bar]
the valve closes. A pop-out indicator button Therefore, the use of a Magnetic Switch Adapter
Coil Rating: Intermittent duty; coil
informs you when the valve is open or closed. for CD ignition systems is recommended. The
type must match power source;
The valve’s tripping power is provided by an • CD ignition coil resistance: 72 Ω adapter stores energy from the CD ignition to
engine ignition system or battery. Models are avail- CD primary voltage: 1.38 to 3.8 A trip the fuel valve. Three models are available:
able for magneto, CD ignition or 12/24 V battery. • M5081FS model: Energized to run 65020126: For Negative Ground CD Ignitions
The M2582 is a 1 inch (25 mm) valve with 1 (continuous-duty coil) coil resistance: up to 240 VDC
NPT connections. It has one SPDT snap-switch. 12 Volt model: 33 Ω (0.36 A) 65020127: For Positive Ground CD Ignitions up
The valve body is made of sandcast aluminum. It 24 Volt model: 136 Ω (0.17 A) to 450 VDC
does not include the open/close indicator button. • Magneto ignition coil resistance: 0.5 Ω 65020155: For Negative Ground CD Ignitions
M5081 is a 2 inch (51 mm) valve with 2 NPT • Magneto primary voltage: 1 to 5 A 240 VDC to 450 VDC
connections. It has two SPDT snap-switches. • Battery coil resistance : 7 Ω
The valve body is available in sandcast alu- 12 or 24 VDC: 1.2 to 2.4 A
minum or cast steel (optional). Wiring (See Internal Wiring page 2): Warranty
M5081FS is the same as the M5081 but has a • M2582: Wire leads A limited warranty on materials and workmanship
is given with this FW Murphy product. A copy of
normally energized circuit. This circuit allows • M5081 and M5081FS: Terminal blocks the warranty may be viewed or printed by going to
the valve to be held open electrically and close Snap-switch Rating: 5 A @ 480 VAC www.fwmurphy.com/support/warranty.htm
by interruption of the coil’s power circuit. A
Laboratory Approval: CSA listed for Class I,
manual trip knob is not available on this model.
Groups C and D Hazardous Locations. 5 amps
An optional 2 in. (51 mm) steel flange pipe con-
maximum; intermittent duty; models M5081 and
nection is available for M5081 and M5081FS
steel body models (see Dimensions page 3). M5081-CD engine ignition powered, and model
M5081-B, 12 or 24 VAC or VDC; switch con-
tacts rated 5 A @ 480 VAC maximum.
Flow Rates Internal Wiring

M2582 M2582
10.0

]
]
g.)
bar]

]
[254.0]

bar
bar

bar
.28 k

38
.69
0.34

.07
9.0

[1.
g.)
[228.6]

) [0

) [2
z. (0
a) [
11 k
Inches water column (∆p) drop across valve.

)
kPa

kPa
kPa
8.0

10 o
4 kP
Optional

. (0.
[203.2]
Millimeters water column in brackets [ ].

38

07
(69
Resistor

ig (3

g (1

g (2
4 oz
7.0 (See Note)

sig
[177.8]

psi

psi
5 ps
10 p
White

20

30
6.0
[152.4]
Black
5.0
[127.0]

4.0 Ground
[101.6] Red

3.0
[76.2]

2.0
[50.8]

1.0
[25.4]
NOTE: For grounding the ignition (CD models only) through the fuel
0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
valve’s internal snap-switch, a Murphy Magnetic Switch adapter (see page 4)
[7.08] [14.16] [21.24] [28.32] [35.40] [42.48] [4956] [56.64] [63.72] [70.80] [77.88] [84.96]
must be used in addition to a 100 ohm, 2 watt resistor (supplied with valve).
Standard cubic feet per hour. Cubic meters per hour in brackets [ ].

M5081 and M5081FS M5081 and M5081FS


M5081 M5081FS
Inches water column (∆p) drop across valve.

Valve Disconnect Switches


Ignition 1 Ignition 2 Valve Coil
Coil Switch 2
Millimeters water column in brackets [ ].

(see Note) Switch 1


g.)
1k
(.1
z.

3.0
4o

.)

[76.2] Ground Ground


kg
28
. (.
oz
10

2.0
]
[50.8] bar
a ) [.69
kP
(69 bar]
sig [1.38
1.0 10 p 38 kPa) 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
1 ]
sig ( 7 bar
[25.4]
20 p ) [2.0
(2 0 7 kPa
ig
30 ps Jumper Jumper Optional
Resistor
(See Note)
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
[14.16] [28.32] [42.48] [56.64] [70.80] [84.96] [99.12] [113.28] [127.44] [141.60] NOTE: For grounding the ignition (CD models only) through the fuel
valve’s internal snap-switch, a Murphy Magnetic Switch adapter (see page 4)
Standard cubic feet per hour. Cubic meters per hour in brackets [ ].
must be used in addition to a 100 ohm, 2 watt resistor (supplied with valve).

MV-94134B page 2 of 4
Dimensions

M2582 Steel Flanged Option “3”


(available on M5081 and M5081FS steel body
configurations only)
Latching Handle 1/2 NPT Conduit
latches valve open Connection
Manual
Disconnect 3-5/8 in.
knob trips valve (92 mm)
diameter

1 NPT 45°
(2 places)

7-5/16 in.
1/4 NPT (186 mm)
Vent and
Plug 3/4 in. (19 mm) dia.
3-3/32 in. (4 places) each end
(79 mm) 2 in. (51 mm) dia.
equally spaced on a
2 places 150# RF
14-25/64 to 14-29/64 in. 4-3/4 in. (121 mm)
5-1/2 in. (140 mm) (raised face) pipe flange
(366/367 mm) b.c. (bolt circle)

M5081 and M5081FS

Manual Disconnect
knob trips valve Latching Handle 1/2 NPT Conduit
(M5081 only) latches valve open Connection (2 plcs.)
1-3/8 in. (35 mm)
1/2 NPT
Conduit 10-5/16 in.
(262 mm)
Inlet
Breather
3-7/16 in.
Valve (87 mm)
Open/Close
Indicator
Button

4-1/16 in.
2 NPT (103 mm)
Vent and Plug (2 places)
1/2 NPT
3 in. (76 mm)
9-3/8 in. (238 mm) 7-3/4 in. (197 mm)

MV-94134B page 3 of 4
How to Order
To order your valve, use the diagram below to specify your model and options. Accessories
Example: M5081-A-2 Specify part number when ordering.
Magnetic Switch Adapter
_____ – __ – __
Base Models 65020126: For Negative Ground CD Ignitions
M2582 up to 240 VDC
M5081 Body Material 65020127: For Positive Ground
M5081FS Blank = Aluminum CD Ignitions up to 450 VDC
2 = Steel (M5081 and M5081FS only)
65020155: For Negative Ground
3 = Steel body with steel flange mounting
(M5081 and M5081FS only) CD Ignitions 240 VDC to 450 VDC
Trip Coil
A = Magneto ignition
Diode Package
B = Battery 65010065: For use with dual
C = CD ignition Magneto Ignition systems.
Coil for M5081FS model only
A = 12 VDC
B = 24 VDC

Shipping Information Service Parts


Specify part number when ordering.
Shipping Weights:
• M2582: 5 lbs 8 oz. (2.49 kg) M2582 M5081 M5081FS
• M5081: 14 lbs 8 oz. (6.58 kg) Coil Assembly
Battery 55000128 55000126
• M5081-2: 40 lbs (18.14 kg) 55000129 55000127
CD Ignition
• M5081-3: 56 lbs (25.40 kg) Magneto Ignition 55000094 55000080
• M5081FS: 14 lbs 8 oz. (6.58 kg) “FS” Coil Assembly
• M5081FS-2: 40 lbs (18.14 kg) 12 VDC 55000158
• M5081FS-3: 56 lbs (25.40 kg) 24 VDC 55000159
Latch Block Assembly
Shipping Dimensions: Latch block assembly 55000095 55000074
• M2582: 8 x 8 x 7 in. (203 x 203 x 178 mm) Latch block switch and coil assembly 55000144
Latch block switch and mounting bracket assembly 55000118
• M5081: 12 x 12 x 9-5/16 in. (305 x 305 x
Handle and Latch Kit
237 mm)
Handle and latch kit 55000102 55000102
• M5081-2: 12 x 12 x 9-5/16 in. (305 x 305 x Handle kit 55000096
237 mm) Manual DIsconnect Assembly 55000097 55000137
• M5081-3: 18 x 12 x 13-1/2 in. (457 x 305 x Snap-switch Assembly 55000098 55000072 55000160
343 mm) Close/Open Indicator Assembly 5500-0138 55000138
• M5081FS: 12 x 12 x 9-5/16 in. (305 x 305 Stem and Seat Kit 55000093 55000075 55000135
x 237 mm) 55000161 (12V)
Top Works Complete Valve Less Body and Vent 55000146 55000131
• M5081FS-2: 12 x 12 x 9-5/16 in. (305 x 55000194 (24V)

305 x 237 mm) Vent Bushing Assembly 55000143 55000132 55000132


Diaphragm Assembly
• M5081FS-3: 18 x 12 x 13-1/2 in. (457 x
Pilot Diaphragm
305 x 343 mm)
Diode Package for Dual Magneto Ignitions 65010065
Magnetic Switch Adapter for CD Ignitions
Single/Dual ign. – negative ground up to 240 VDC 65020126 65020126
Single/Dual ign. – positive ground up to 450 VDC 65020127 65020127
Single/Dual ign. – negative ground up to 450 VDC 65020155 65020155

FW MURPHY CONTROL SYSTEMS & SERVICES DIVISION COMPUTRONIC CONTROLS, LTD


P.O. Box 470248 P.O. Box 1819 41 - 43 Railway Terrace Nechells
Tulsa, Oklahoma 74147 USA Rosenberg, Texas 77471 USA Birmingham B7 5NG UK
+1 918 317 4100 Fax: +1 918 317 4266 Phone: +1 281 633 4500 Fax: +1 281 633 4588 Phone: +44 121 327 8500 Fax: +44 121 327 8501
E-mail: sales@fwmurphy.com E-mail: sales@fwmurphy.com E-mail: info@computroniccontrols.com
INDUSTRIAL PANEL DIVISION FRANK W. MURPHY, LTD Web site: www.computroniccontrols.com
Fax: +1 918 317 4124 Church Rd Laverstock FW MURPHY INSTRUMENTS (HANGZHOU) CO. LTD
E-mail: ipdsales@fwmurphy.com Salisbury SP1 1QZ UK 77 23rd Street
MURPHY POWER IGNITION Phone: +44 172 241 0055 Fax: +44 172 241 0088 Hangzhou Economic & Technological Development Area
Web site: www.murphy-pi.com E-mail: sales@fwmurphy.co.uk Hangzhou, Zhejiang 310018 China
Web site: www.fwmurphy.co.uk Phone: +86 571 8788 6060 Fax: +86 571 8684 8878
www.fwmurphy.com Printed in U.S.A.

MV-94134B page 4 of 4