You are on page 1of 128

Heat Rate Improvement Reference Manual

Training Guidelines

11142678
11142678
Heat Rate Improvement Reference Manual
Training Guidelines

TM-114073

Training Manual, December 1999

EPRI Project Manager

P. Ruestman

EPRI • 3412 Hillview Avenue, Palo Alto, California 94304 • PO Box 10412, Palo Alto, California 94303 • USA
800.313.3774 • 650.855.2121 • askepri@epri.com • www.epri.com

11142678
DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES
THIS DOCUMENT WAS PREPARED BY THE ORGANIZATION(S) NAMED BELOW AS AN ACCOUNT OF
WORK SPONSORED OR COSPONSORED BY THE ELECTRIC POWER RESEARCH INSTITUTE, INC.
(EPRI). NEITHER EPRI, ANY MEMBER OF EPRI, ANY COSPONSOR, THE ORGANIZATION(S) BELOW,
NOR ANY PERSON ACTING ON BEHALF OF ANY OF THEM:

(A) MAKES ANY WARRANTY OR REPRESENTATION WHATSOEVER, EXPRESS OR IMPLIED, (I) WITH
RESPECT TO THE USE OF ANY INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM
DISCLOSED IN THIS DOCUMENT, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, OR (II) THAT SUCH USE DOES NOT INFRINGE ON OR INTERFERE WITH PRIVATELY OWNED
RIGHTS, INCLUDING ANY PARTY'S INTELLECTUAL PROPERTY, OR (III) THAT THIS DOCUMENT IS
SUITABLE TO ANY PARTICULAR USER'S CIRCUMSTANCE; OR

(B) ASSUMES RESPONSIBILITY FOR ANY DAMAGES OR OTHER LIABILITY WHATSOEVER (INCLUDING
ANY CONSEQUENTIAL DAMAGES, EVEN IF EPRI OR ANY EPRI REPRESENTATIVE HAS BEEN ADVISED
OF THE POSSIBILITY OF SUCH DAMAGES) RESULTING FROM YOUR SELECTION OR USE OF THIS
DOCUMENT OR ANY INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM DISCLOSED
IN THIS DOCUMENT.

ORGANIZATION(S) THAT PREPARED THIS DOCUMENT

EPRI

Duke/Fluor Daniel

ORDERING INFORMATION
Requests for copies of this report should be directed to the EPRI Distribution Center, 207 Coggins Drive,
P.O. Box 23205, Pleasant Hill, CA 94523, (925) 934-4212.

Electric Power Research Institute and EPRI are registered service marks of the Electric Power Research
Institute, Inc. EPRI. POWERING PROGRESS is a service mark of the Electric Power Research Institute, Inc.

Copyright © 1999 Electric Power Research Institute, Inc. All rights reserved.

11142678
CITATIONS

This document was prepared by


Duke/Fluor Daniel
DFo1A
2300 Yorkmont Road
Charlotte, North Carolina 28217-4522
Principal Investigator
R. Snyder

EPRI
3412 Hillview Avenue
Palo Alto, CA 94304
Principal Investigator or Author
J. Tsou

This document describes research sponsored by EPRI.


The publication is a corporate document that should be cited in the literature in the
following manner:
Heat Rate Improvement Reference Manual, Training Guideline, EPRI, Palo Alto, CA,
1999. TM-114073.

11142678 i
11142678
ACKNOWLEDGEMENT

EPRI wishes to acknowledge members of the Heat Rate Interest Group for providing
guidance in development of this manual and training guide. EPRI also wishes to
acknowledge the following people for reviewing and providing comments to the draft
manual and training guideline.

Duane Hill, Dairyland Power Cooperative


Wes Hull, Central and South West Services
Sam Korellis, Illinois Power Company"

11142678 iii
11142678
ABSTRACT
Performance optimization of fossil power plants has always been a high priority within the
electric power industry. However, it has become of paramount importance in meeting the
challenges mandated by operating within a competitive environment. Recently, many
power producers have downsized and currently lack experienced staff required to maintain
optimal performance. Thus, a resource was needed to capture the lost experience to aid in
the retraining of less experienced personnel.
The objective of this project was to produce a manual to be used by power producers as a
training tool and reference source for the development of heat rate and performance
engineers. This document provides required information to understand thermodynamic
properties and precepts, guidance on how to use them and methods of determination to
assess their impact on system performance.
This training guide, a compliment to the reference manual, used EPRI CS-4554 Heat Rate
Improvement Guidelines as a basis for development of the program. Specifically, this
manual includes:
• A description of the properties of water, its phases, and the determination of each. A
discussion of the Steam Tables and Mollier diagram and how each is used to find the
properties of water/steam. A brief discussion of the Ideal Gas Law.

• A definition and application of the concepts of the first law of thermodynamics and
required energy conversion calculations to power plant components. The relationship is
used to develop an understanding of how plant parameters are affected by the operation
of the components.
• A review of the principles and applications of fluid flow. Discussion includes pumps
and pump operation for forced fluid flow.
• A discussion of the concept of thermal efficiency and the methods employed to
maximize efficiency.
• An explanation of the various modes of heat transfer and the equations used with each
mode. It gives an introduction to nucleate boiling and the factors affecting DNB.
A discussion of natural circulation and a brief discussion on heat exchangers are also
covered.
• An explanation and review of power plant systems, which include the water/steam
cycle, boiler fuel, air and flue gas systems, as well as, balance of plant systems.
• An introduction to the ‘Heat Rate Improvement Reference Manual’, the purpose,
organization and use of the manual.

11142678 v
11142678
REVIEW OF THERMODYNAMIC

PROPERTIES (1)

11142678
1. OVERVIEW:
This Lesson Plan describes the properties of water, its phases, and the determination
of each. It also includes a discussion of the Steam Tables and Mollier diagram and
how each is used to find the properties of water/steam. A brief discussion of the Ideal
Gas Law is also included.

2
11142678
TERMINAL OBJECTIVE:
At the end of this class the student should have a working knowledge of
Thermodynamic principles that can be used by those involved in the Heat Rate
Improvement Program. This will be accomplished by meeting the requirements of the
following enabling objectives.
ENABLING OBJECTIVES:

1. Define each of the following terms:


1.1 Temperature
1.2 Pressure
1.3 Density and Specific Volume
1.4 Enthalpy
1.5 Entropy
1.6 Specific Heat Capacity
1.7 BTU

2. Convert a known temperature from one scale to another.

3. Convert a known pressure from one scale to another.

4. State and define the different phases of water.

5. Explain each of the following


5.1 Saturation Temperature
5.2 Latent heat
5.3 Quality
5.4 Sensible Heat

6. Given a set of conditions and using the steam tables, determine the
thermodynamic properties and phases of water.

7. Given a set of conditions using the Mollier diagram determine the


properties and phases of water.

11142678
8. Using the ideal gas law, solve problems relating to pressure, temperature
and volume of an ideal gas.

11142678
LESSON OUTLINE

1. INTRODUCTION

2. PRESENTATION
2.1 Fluid Properties
2.2 Temperature
2.3 Pressure
2.4 Specific Volume
2.5 Enthalpy
2.6 Entropy

3. DETERMINING THE PROPERTIES OF WATER


3.1 Steam Tables
3.2 Phase of Water
3.3 Mollier Diagram

4. GAS RELATIONSHIP
4.1 Ideal Gases

11142678
1. INTRODUCTION
1.1 Overview
This lesson covers the properties of water/steam and the phases of water. It
also covers the steam tables and Mollier diagram and their use in the power
plant.
1.2 Objectives

2. PRESENTATION
2.1 Fluid Properties
The thermodynamic properties of a fluid are measurable or quantifiable
characteristics of the fluid and include the following:
Temperature Internal Energy
Pressure Enthalpy
Specific Volume Entropy
2.2 Temperature
A. Definition: A measure of the average molecular kinetic energy:
(Thermal Driving Head)
B. Temperature Scales
1. Absolute °R and °K:
• R = °F + 460(459.69°)
• K = °C + 273
2. Relative °F = (1.8 x C) + 32
oF is used most often, but oR is used when absolute temperatures are
required.
2.3 Pressure
A. Definition: Force per unit area (P=F/A)
B. Scales
1. PSIA = (Absolute Pressure)
a) Pressure above a perfect vacuum
b) Atmospheric pressure + gauge pressure
2. PSIV = Pressure measured below a reference (atmospheric pressure)

11142678
a) PSIG = Gage pressure = pressure measured from atmospheric
b) (PSIG = PSIA - ATMOS)
3. Inches of Hg Pressure (1 PSIA~- 2" Mercury Hg)
4. Inches of Hg Vacuum = PSIV x 2
2.4 Specific Volume (V) and Density (ρ)
A. Definition of Specific Volume: Volume per unit mass.
v = Volume = ft3
Mass lbm
B. Definition of Density (ρ): The inverse of Specific Volume
1 = lbm
v ft3
C. Specific Volume and Density are affected by temperature and pressure.
Pressure: as pressure Temperature: as
temperature
↑ ↓ ↑ ↓
v ↓ ↑ ↑ ↓
ρ ↑ ↓ ↓ ↑
1. Example:Using the Steam Tables find the density of a saturated liquid at
200oF.
v = 0.016637 ft3/lbm
ρ = 1/v = 1/0.016637 = 60.1 lbm/ft3
2. Now raise its temperature to 300oF. v = 0.01745 - ft3/lbm
ρ = 1/v = 1/0.01745 = 57.3 lbm/ft3
2.5 Internal Energy
A. Definition: Thermal energy stored within a substance itself. This is due to the
position and movement of the molecules or atoms which make up a
substance in relation to each other.
B. Enthalpy (h)
1. Definition
a) Sum of the internal energy and pv (pressure x specific volume)
(flow) energy.

11142678
b) Energy content of one pound mass of a fluid at a given temperature
and pressure. Units of heat energy are in BTU’s which stands for
British Thermal Units.
C. h = specific enthalpy; h = u + pv, where u = Specific Internal Energy in
BTU/lbm
1. h = BTU/lbm
To convert pv to BTU/lbm divided by Joules Constant = 778 ft- 1bf/BTU
pv = Flow energy due to pressure and volume.
pv = BTU
J lbm
2. Example: Find the internal specific energy of saturated steam at 1000
psia.
h = u + pv = h - pv
J J
u = 1192.9 BTU - (1000 lb) (144 in2) (0.44596 ft3/lbm)
lbm in2 ft2 778 ft - 1bf
BTU
u = 1110.4 BTU
lbm
3. Notice that nearly all the enthalpy was internal energy.
Generally a change in internal energy results in a change in
temperature, but not always.
PROOF: For a saturated liquid at 1000 psia, find the internal energy.
U = H - pv = 542.6 BTU - (1000)(144)0.02159
j lbm 778ft_-_1bf
BTU
U = 538.6 BTU
lbm
At 1000 psia, the change in internal energy is from 538.6 to 1110.4
BTU/lbm, but the temperature remained constant. The only change
was a change from a saturated liquid to a saturated vapor.
D. Total Enthalpy (H)
1. Total energy of a given mass (H = U + pv)
2. To find total enthalpy, simply multiply specific enthalpy times the amount
of mass present.
H = (h)(m)
8

11142678
2.6 Entropy (S)
A. Definition: A measure of the unavailable energy in a fluid @ a given
temperature and pressure.
Units: BTU on an absolute scale
lbm-oR
OR:
BTU
lbm - oF on a relative scale
We are more interested in Entropy changes (Delta S = Sfinal - Sinitial) than
specific values of Entropy.
1. Example:Find Delta S when energy is added to a saturated liquid @ 100
oF and changes the saturated liquid to a saturated vapor @ 300oF
Delta S = Sfinal - Sinitial

Delta S = Sg - Sf Sf@ 100oF = 0.1295 BTU/lbmoF


Sg@ 300oF = 1.6351 BTU/lbmoF

Delta S = 1.6351 - 0.1295


Delta S = 1.5056 BTU/lbmoF
2. The point is, as heat is added to this example, more of the energy of the
liquid-vapor is unavailable. Also the reverse is true for removing energy
which results in a decrease in entropy.
3. The change in entropy (Delta S) is used to account for the energy that
has been made unavailable for work.
4. For example: Use the main condenser.
a) When steam is condensed, the temperature remains constant, but
the entropy decreases.
b) If condenser pressure is 1 psia, saturated steam exhausts from the
turbine into the condenser and condenses with no subcooling. Find
the heat rejected
.(qrej)

11142678
qrej = T (Delta S) at 1 psia Sf = 0.1325 BTU/lbmoF

Sg = 1.9781 BTU/lbmoF

T = oF + 460
= 101.74 + 460 =
561.74oR
1) qrej = (561.74)(0.1326 - 1.9781)
2) qrej = 1036.12 BTU's Rejected
5. Notice the qrej is equal to hfg which is the Latent Heat of Condensation.
The BTU's are the BTU's or heat given to the Condenser Circulating
Water (CCW) System.
6. Qualitatively: We can say that S of condensate decreased when heat
was removed and S of CCW increased as heat was added.
7. Summary: The energy that is available in the condensate to do work
(useful) per lbmoF has increased. This is mainly due to the
inadequacies of the working fluid and the process. Also, the value of hfg
indicates that amount of energy that has become unavailable in our
work process is S .
B. Discussion of T-S Diagram

2200 PSIA 1000 PSIA


1000

900 2 PSIA

800 CRITICAL
POINT
TEMPERATURE ( F )

700

SUBC. LIQUID
600 Sf
SUPER HEATED
VAPOR
500 Sg

400

300 WET VAPOR


Sfg

200

100

0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4
ENTROPY ( BTU/lbm - R

43

10

11142678
1. We assume that at 32oF, S = 0 (Even though S = 0 at O oR).
2. Saturation Line: Every single point on the line, to the left of the critical
point is where a saturated liquid exists.
3. Critical Point: At these conditions of temperature (705.47oF) and
pressure (3208.2 psia), the following is true.
a) There is no difference in specific volume between a saturated liquid
and a saturated vapor.
b) There is no difference in enthalpy between a saturated liquid and a
saturated vapor.
c) There is no difference in entropy between a saturated liquid and a
saturated vapor.
OR
vf = vg vfg = 0 hf = Hg hfg = 0 Sf = sg sfg = 0
At the critical point, the liquid/vapor acts like a perfect gas.
4. Subcooled Region: Region left of critical point and left of saturated
liquid line.
5. Wet Vapor Region: Area under saturation line.
6. Constant Pressure Lines: From the point where it touches the saturated
liquid line, it is horizontal until it touches the saturated vapor line.
7. Enthalpy Lines: Range from 100-1800 (bottom-top) and extend
horizontally across the entire diagram.
8. In order to locate a point on the diagram for any condition except at
saturated conditions, you must know two properties of the liquid, wet
vapor, or superheated steam.
9. If you are a saturated liquid at 212oF.
a) Pressure is found by noting where constant pressure line touches
sat. liquid curve for 212oF.
b) Enthalpy is the horizontal line crossing through the sat. liquid line for
212oF.
c) Entropy is the vertical line crossing through the sat. liquid line for
212oF.
d) Ex. a saturated liquid at 212oF. P = 15 psia
h = 1150 BTU/lbm
Ss = 1.75
BTU/lbmoR 11

11142678
10. Go back to condenser example
a) 1 psia, saturated liquid = 100oF by T-s diagram.
b) The saturated steam changed to saturated liquid.
Note that enthalpy and entropy decreased.
Sinitial = 1.98 Sfinal = 0.12
c) Heat rejected from condenser was heat added to Condenser
Circulating water.

3. DETERMINING THE PROPERTIES OF WATER


3.1 Steam Tables
A. The Steam Table consist of 3 separate tables
1. Table 1. Saturated Steam: Temperature Table
a) Consists of columns for:
1) Temperature
2) Pressure - corresponds to temperature for saturation conditions.
3) Specify Volume
4) Enthalpy
5) Entropy
b) The v, h, and s columns each have values for saturated liquid (vf)
saturated vapor (vg), and the change (vfg) from liquid to vapor.
2. Table 2. Saturated steam: Pressure Table
a) This table is set up the same as table except the temperature and
pressure columns are reversed.
3. Table 3. Superheated steam
a) This table is set up differently. It consists of:
1) Abs pressure column with sat. temperature in parentheses.
2) Across the top is temperature - degrees Fahrenheit. This
represents the actual temp of the steam.
3) Sh column represents the degrees super heat.
4) It then has columns for v, h, and s.
4. The last part of the steam tables is a conversion factors chart used for
converting from one parameter to another.

12

11142678
3.2 Specific Heat
A. Definition: Specific heat capacity (c)
1. Heat required to cause 1 lbm of any substance to change by 1oF.
2. Sensible heat - heat added that raises the temperature of water.
c = BTU
lbm oF
3.3 Phases of Water
There are 5 exact phases of water that we consider in the power industry.
A. Subcooled Liquid (Compressed Liquid)
1. Liquid below the boiling point.
2. Enthalpy (h) of a subcooled liquid is determined by one of the following
methods.
a) Definition: Heat required to cause 1 lbm of any substance to
change by 1oF. Heat added that raises the temperature of water is
"sensible heat".
c = BTU
lbm oF
b) Subtract 32oF from the temperature and use the units of enthalpy
(BTU/lbm).
NOTE: Below~- 300oF, this is a fairly accurate method. But > 300o
F, the accuracy drops due to changes in the Specific Heat
Capacity of the fluid, i.e., it takes more and more heat to
cause the temperature to change by 1oF as its temperature
increases.
c = Specific Heat Capacity (Assume 1.4 BTU/lbmoF for Reactor
Coolant)
c) The most desirable (most accurate) method to find h is to look up
temperature of liquid in the steam tables and assume hsc = hf
T-32
STM Table Method Actual
hf hf
Assume at 400psi
(Example on two methods)
hsc @ 100oF => 68 68
13

11142678
69.5
hsc @ 200oF => 168 168 169

hsc @ 300oF => 269.7 268 270.3

hsc @ 400oF => 375.1 368 375.3


Conclusions
1) Note the increasing error.
2) Use steam table method
B. Saturated Liquid
1. Water at the boiling point
2. The properties of Hf, sf, vf, Tsat, Psat are found in the Saturated Steam
Tables.
3. Example: find hf @ 100 psia

100 oF
300 psia
300oF
100 psia
C. Wet Vapor
1. A combination of saturated liquid and saturated steam at the boiling
point.
2. Enthalpy is determined by:
hwv = hf + x(hfg) Where hwv = Enthalpy Wet Vapor
hf = Enthalpy Liquid
x = Quality of Vapor
hfg = Latent Heat of Vaporization
(hfg = The latent heat of vaporization or condensation)
Numerically, hfg is the amount of heat which must be added to 1 lbm of
a saturated liquid to change it to 1 lbm of steam or the amount of heat
which must be removed to change 1 lbm of saturated steam to 1 lbm of
saturated liquid.

14

11142678
3. x = Quality = amount of vapor in a wet vapor.
x = 100%-m (m = % moisture in a wet vapor)
4. Example: Find hfg @ 1 psia
100 psia
300 oF
1000 psia
5. Example: Find enthalpy of wet vapor @ 500 psia if m = 15%.
a) hwv = hf + (xhfg)
D. Saturated Steam
1. Steam at the boiling point (no moisture, 100% vapor).
2. The properties of hg, sg, vg, Tsat, Psat are found on the saturated
steam tables.
3. Example:
Find: hg vg sg for the following

460oF
180oF
400 psia
1000 psia
E. Superheated Steam
1. Steam above the boiling point
2. The properties of h, s, v, P, and T are found in the superheated steam
tables.
3. Superheat term refers to # of degrees above Tsat.

4. Example: Find Tsh @ 400, 450, 500oF when @ 100 psia.

3.4 Mollier Diagram

15

11142678
M OLLIER

A
PSI
280

45
1172 BTUs
240

E
INL

IA
T.

PS
SA

15
M OISTURE

A. A pictorial representation of steam tables (does not contain specific volume)


called a H-S diagram.
1. Find h of steam at saturation with x = 100% and 900 psia.
a) From Mollier on saturated steam line h =
b) From steam tables h=
2. Find the temperature and h of a system at 500 psia and 20o superheat.
a) T = h=
3. Find the enthalpy and temperature of a system at 300 psia for the
following.
a) Saturated:
b) m = 4% :
Note that since we are under saturation line;
c) m = 12%: temperature is constant.

4. GAS RELATIONSHIP
4.1 Ideal Gases

16

11142678
A. Ideal gases are described as gases comprised of molecules that do not
interact with one another. The pressure exerted by an ideal gas is the force
exerted on the surface by the collision of these molecules. The forces
exerted by the molecules increase with the absolute KE as measured by
temperature. Similarly, the pressure exerted by the molecules increases as
the density of the molecules increases. So we can say that,
P α PT Since ρ = m/v, we can substitute and rearrange as follows:
P α m/v T, or
P v = T for 1 lbm.
If we compare initial and final conditions on a particular system of ideal gas
we can write the equation.
(P1 V1)/T1 = P2V2 /T2
This is the ideal gas law.
B. The Ideal Gas Law is actually a combination, of 2 laws; Charles Law and
Boyles law.
1. Charles Law states: The volume of a given mass of gas, maintained at
constant pressure, varies linearly with temperature or,
V1 T1
=
V2 T2
2. Boyles Law states: For a fixed mass of gas at a constant temperature,
the volume of gas is inversely proportional to its pressure or,
P1V1 = P2V2
C. All pressures and temperatures must be in absolute scales.
D. Examples:
If 20 cu ft of Nitrogen at 15 psia is heated from 73oF to 150oF, what will be
the pressure if the volume remains constant?
P1V1 P2V2
=
T1 T2

15 1b/in2 (20 ft3) P(20 ft3)


=
(73 + 460) oR (150 + 460) oR
17 psia = P2

17

11142678
11142678
REVIEW OF THERMODYNAMIC

PROPERTIES (2)

11142678
1. OVERVIEW
This Lesson Plan defines and applies the concept of the first law of Thermodynamics
and Energy conversions to power plant components. This relationship is used to
develop an understanding of how plant parameters are affected by the operation of
the components.

11142678
TERMINAL OBJECTIVE:
At the end of this lesson the students will have a working knowledge of the First Law
of Thermodynamics and Energy Conversions.

ENABLING OBJECTIVES:

1. List and define the six energy forms considered in the study of
Thermodynamics.

2. Identify the properties which indicate a change in each of the six energy
forms.

3. State the First Law of Thermodynamics

4. State the Continuity Equation and apply it in determining mass flow rate,
volume flow rate and velocity changes in power plant components.

5. Describe the energy conversions which occur in a moving fluid and relate
them to changes in observable parameters and fluid properties for:
5.1 Constant diameter pipe
5.2 Nozzle and venturi
5.3 Throttling device
5.4 Pump
5.5 Turbine

6. Plot the throttling process on a Mollier Diagram and determine fluid


properties upstream and downstream, given appropriate information.

7. Define pump efficiency.

8. Determine turbine work and power given appropriate information.

9. Define turbine efficiency.

11142678
LESSON OUTLINE

1. INTRODUCTION
1.1 Purpose of this lesson
1.2 Overview

2. THE ENERGY FORMS ASSOCIATED WITH THERMODYNAMICS


2.1 Energy
2.2 Forms of Energy

3. THE FIRST LAW OF THERMODYNAMICS APPLIED


3.1 First law of Thermodynamics
3.2 The Steady Flow Energy Equation
3.3 Power

4. APPLICATIONS OF THE GENERAL EQUATION


4.1 Constant Diameter Pipe
4.2 Nozzle and Venturi
4.3 Throttling Device
4.4 Pump
4.5 Turbine

5. ATTACHMENT 1

11142678
1. INTRODUCTION
1.1 Purpose of this lesson
A. Develop concepts of energy conversion within power plant components.
B. Apply the concepts in order to enable the student to predict the effects on
system parameters.
C. Predict the effects of changing operational conditions on plant parameters.
D. Develop the building blocks which will be used in the power plant cycles
lesson.
1.2 Overview of the lesson - Review objectives.

2. ENERGY AND THE ENERGY FORMS ASSOCIATED WITH


THERMODYNAMICS
2.1 Energy
A. Energy is defined as the capacity for producing an effect
1. The effect produced is frequently mechanical work thus the common
definition is "the capacity for doing work."
2. Energy in some forms is intangible but the effects produced can usually
be evaluated
B. General Methods of Classifying Energy
1. Stored energy and energy in transition
a) Energy in Transition
1) Momentary energy form; in an intermediate state between two
or more stored forms
2) Begins and ends as stored energy
3) Heat and work are the forms of energy in transition
b) Stored Energy
1) Energy associated with or contained in systems or bodies such
as the working fluid
2) The stored energy forms we will be dealing with are:
(a) Kinetic
(b) Potential
(c) Flow or Pv
(d) Internal

11142678
2. Mechanical and Thermal Energy
a) Mechanical Energy
1) Energy which stems from the position or motion of relatively
large bodies
2) Forms of Mechanical Energy
(a) Kinetic
(b) Flow or Pv
(c) Potential
(d) Mechanical Work
3) Transfer of mechanical energy is by physical contact between
large masses either directly or through a machine such as a
moving shaft or piston
4) Unit of mechanical energy is the foot pound force (ft-lbf)
b) Thermal Energy
1) Energy associated with the configuration and motion of
molecules
2) Characterized by its ability to be transferred from one body to
another by temperature difference alone
3) The mechanism of thermal energy transfer is through the
collision of molecules or electromagnetic waves
4) Forms of thermal energy
(a) Internal energy
(b) Heat
5) Unit of thermal energy is the British Thermal Unit (BTU)
c) Relating mechanical and thermal energy
1) Joules equivalent, the mechanical equivalent of heat is the
mathematical relationship between units used to express
mechanical energy and thermal energy. Symbol J
2) 778 ft lbf = 1 BTU
or J = 778 ft lbf / BTU

11142678
C. Kinetic Energy - Stored mechanical energy due to the mass and velocity that
the mass has or the work to bring mass up to observed velocity

1. KE = MV2 gc = 32 lbm ft
2gc lbf sec2
2. The parameter that is an indication of the KE of a fluid is the velocity

KE α V2
D. Potential Energy (PE) - Stored mechanical energy associated with the
elevation relative to a reference elevation or work done in bringing a mass
from Ref to Height Z.
1. PE = mgz / gc
or PE per unit mass = gz / gc
2. Height is an indication of PE
E. Flow work or displacement energy(Wf) - stored mechanical
1. The Energy necessary to maintain a continuous steady flow of a stream
of fluid
2. Flow work is not present unless there is flow
3. W f is the product of the force acting on any cross-section of the stream
and the distance through which the force must act to cause any selected
mass to pass that cross section
4. Thus W f = Pv
P = Pressure
v = Specific volume of the fluid
5. Derivation - optional
Wk = Force (F) x L
F = P(press) A(area)
Volume (V) = A(area) L(length)
V also equals Mass(M) v (specific volume)
Therefore AL = Mv
PAL = PMv therefore Wk = PMv
and the work per unit mass is Wf = pv

11142678
F. Internal Energy (u) - Stored thermal energy associated with the molecules
and atoms of a substance
1. Majority is contained as vibrational KE of the molecules and atoms of a
substance
a) Temperature is a measure of this energy
b) Also energy associated with the spin of molecules
c) And the spacing between molecules
2. The energy distribution between these various forms of internal energy
is what causes the heat capacity of a substance to vary
Example: At low temp Cp of H20 ≅ 1 BTU/ lbm °F
In this condition, almost all of a BTU added goes into the vibrational KE
and therefore will show up as a temperature change.
At high temperatures and pressures Cp H20 ≅ 1.4 BTU / lb-°F
In this case, a portion of the BTU added is going into increasing the spin
and spacing of the molecules => show up as an increase in Cp because
since all the BTU is not directly related to the increase in vibrational
KE.(thus temperature change)
Example Problem:
1) Find the h, Pv, u for a saturated liquid at 500°F

2) hstm table = 487.9 BTU/lbm


3) Pv = PSAT x v =


from stm tables
2
(680.86 lbf/in2)(144 in2/ft )(.02043 ft3/lbm)
__________________________________ =
778 ft-lbf/BTU
Pv = 2.57 BTU/lbm
4) U = h-Pv = 487.9 BTU/lbm - 2.57 BTU/lbm
U = 485.33 BTU/lbm
3. During a phase change all the energy goes to increasing distance
between molecules (internal potential energy), therefore there will be no
increase in temperature of the substance.

11142678
G. Work - Force applied in moving something through a distance
1. W = F x D
2. Units - ft-lbf
3. Work as such cannot be stored, but work done on a system will show up
as an increase of one or more of the stored energy forms.
4. Work done on system is evidenced by a mechanical device passing
through the boundary and is moved by some external source
5. Work is done by a system if the mechanical device is passing through
the boundary and the force which causes movement of this device is
developed from within the system. (Mechanical output such as turbine)
6. Heat - Transient Thermal Energy - Energy transferred from one region
to another due to a temperature difference.
a) Methods of heat transfer
1) Conduction - Heat transfer through a medium
2) Radiation - Heat transfer without a medium via electromagnetic
radiation
3) Convection - Heat transfer by the combined action of
conduction, storage, and mixing of a fluid between regions of
high and low temperature.

3. THE FIRST LAW OF THERMODYNAMICS APPLIED


3.1 First law of Thermodynamics
A. Energy can neither be created nor destroyed but only transformed
B. When applied to a system - Net energy entering the system will equal the
net energy leaving the system plus the energy accumulated within the
system
or
Energy in = Energy out + Energy Accumulated
3.2 The Steady Flow Energy Equation
A. Statement of the first law considering all energy forms assuming steady flow
Energy accumulated = 0 in steady flow.
B. Energy in = Energy out
KE1 + PE1 + Pv1 + u1 + qin + Won = KE2 + PE2 +
Pv2 + u2 + qout + (W by)
Divide the mechanical terms by J to get all in BTU's

11142678
3.3 Power
A. Power is defined as the rate of doing work
B. The General Energy Equation becomes a power equation
when multiplied by M the mass flow rate in lbm/hr
C. Some equivalents
1hp = 2545 BTU/hr = 42.42 BTU/min
= 33000 ft lbf/min = 550 ft lbf/sec
1kw = 3.4 x 103 BTU/hr = 1.34 hp
D. This will be applied to the turbine, pump, and heat exchanger later

4. APPLICATION OF GENERAL ENERGY EQUATIONS


4.1 Energy balance on fluid flowing through a pipe
A. Assumptions:
-Water is incompressible
-Water temperature is ambient
-Area1 = Area2
-No change in height
-Steady flow conditions
B. KE1 + PE1 + u1 +Pv1 + Qin +W on = KE2 + PE2 + u2 + Pv2 +
Qout +W by
C. Since no change in area => KE1 = KE2
D. No change in height => PE1 = PE2
E. No heat in or out and no work done on or by the system
=> Qin & Qout = 0
W by & W on = 0
F. Therefore, we are left with:
U1 + Pv1 = U2 + Pv2
U1 - U2 = v(P2 - P1)

∆U = v∆P

10

11142678
G. Recall that: h = u + Pv
J
1. (u1 + Pv)-(u2 + Pv) = ∆h
J J2
2. u2 > u1 due to friction
3. Pv2 < Pv1 due to drop in fluid energy due to friction
H. The conversion of flow energy (Pv) to internal energy (u) due to friction is
called "Head Loss".
The effects of head loss will be discussed further in the fluid flow lesson.
4.2 Energy Balance on a Nozzle/Venturi
A. Assumptions:
1. Mass flow in = mass flow out
2. Fluid is water = > incompressible
3. No friction
4. Area1 > Area2
5. Area1 = Area3
B. Converging section - nozzle
1. PE1 + KE1 + Pv1 +U1 + Qin + W on =
PE2 + KE2 + Pv2 + U2 + Qout + W by

a) ∆PE = 0 - no change in height


b) ∆U = 0 - no friction
c) Qin & Qout = 0
d) No work done by the system => W by = 0
e) No work done on the system => W on = 0
2. This leaves: KE1 + Pv1 = KE2 + Pv2
Pv1 - Pv2 = KE2 - KE1

∆Pv = ∆KE
3. The continuity equation can be applied to determine which of the energy
terms increased.
a) Since we know that in a steady flow condition
o o
the M M
11

11142678
into a = out of , we can say that
system the system
→ →
ρin Ain Vin = ρout Aout Vout

→ →
ρAV1 = ρAV2 - Since the fluid is water and relatively incompressible
then ρ1 = ρ2.
→ →
Since A2 < A1 then V2 > V1
4. Parameter property changes
• Velocity increases
• Pressure decreases
• Enthalpy decreases
• Temperature Increases - not noticeable
• Entropy Increases - slightly
5. Application
a) Steam turbine nozzles to convert pressure to velocity
b) Air ejector nozzle to create low pressure area
c) Flow measurement

1) ∆P α ∆V2
2) Recall ∆Pv = ∆KE

and KE = 1/2mv2
gc
o
also V α velocity
o
V = Volume Flow Rate (GPM)
3) then
o

∆P α V2
To make an equality use Venturi constant K giving
o

V = K (∆P)1/2
12

11142678
K varies based on friction and geometry and will be affected by
fouling of the Venturi
4) For mass flow rate
o o
M = V x density or
o

M = k (∆P)1/2 (ρ)
d) Diverging section 2 to 3
1) The Reverse Process Occurs
2) Since A3 = A1
(a) Velocity decreases from point 2 to point 3
(b) Pressure will increase
(c) Neglecting friction
Pressure will return to the value at point1 and velocity will
drop to the initial value
3) Effect of friction will result in some pressure drop across the
device
(a) This effect is minimized by the smooth transition
(b) The orifice is not smooth and significant pressure drop
will occur.
4) Application
(a) Inc. NPSH on pump suction
(b) Steam Jet
(c) Pump Volute
(d) Accommodate expansion

13

11142678
4.3 Energy Balance on a Pump
NOTE: Sketch pump on board with suction as Point 1 and Discharge Point 2.
A. Assumptions:
1. No heat transferred in or out
2. No friction
o o
3. Steady flow conditions => Min = Mout

4. The fluid is water => ρin = ρout


5. Suction diameter = Discharge diameter
B. Evaluation using General Energy Equation
1. Pv1 + U1 + KE1 + PE1 + Qin + W on =
Pv2 + U2 + KE2 + PE2 + Qout + W by

a) ∆KE = 0 - at point 2 as compared to point 1


Since A1 = A2

b) ∆pe = 0 - no noticeable difference in height


c) ∆u = 0 - no friction assumption
d) Qin & Qout = 0 - no heat in or out

14

11142678
e) No work by the system => W by = 0
f) W pump = Pv2 - Pv1

W pump = v (∆P)

2. ∆P is called Pump Head and is expressed as:


a) PSID
b) Feet of water (2.31 ft of water = 1 psi) or43 psi = 1 ft.
c) Sometimes ft-lbf
C. Pump power
o o
1. Wpump = M x Wpump
o
Power = M x v∆P
2. If all the power supplied by the prime mover was imported as flow work
the pump would be 100% efficient
3. Pump Efficiency
o
ηpump = output = M V∆P (power into head)
input Brake HP (input by prime mover)
a) Pump efficiency ≅ 85 - 99%
Due to friction and other losses in the pump
D. Parameter & property changes across pump
1. Pessure Increases
2. Velocity constant (assume same disch & suct diameter)
3. Enthralpy increases
4. Entropy increases due to friction and other losses
5. Temperature increases not noticeable
6. U↑
4.4 Energy Balance on a Turbine
NOTE: Sketch Turbine on board with inlet as point 1 and exhaust as point 2
A. Assumptions:
1. No friction => constant entropy
o o
2. Qin and Qout = 0
o o
15

11142678
3. Min = Mout => no extraction flows
4. Inlet pressure is 1000 psia
5. Condenser pressure is 1 psia
NOTE: In the turbine steam is expanded through the stages so specific
volume increases.
B. Energy Balance
1. KE1 + PE1 + Pv1 + U1 +Qin + W on =
KE2 + PE2 + Pv2 + Q2 +U2 + W by
a) Qin and Qout = 0 No heat transfer
b) No work done on => W on = 0

c) ∆KE ≅ 0
Since the steam expands through the turbine and v↑, the area of
the exhaust is made larger to accommodate the expansion. The
result is that there is little difference in velocity between inlet and
outlet.
d) PE - overall height being looked at is 10 to 15 feet.
Any change in PE in this case would be very small compared to the
other changes.
2. U1 + Pv1 = U2 + Pv2 + W by
rearranged to:
W by = (U1 + Pv1) - (U2 + Pv2)
and since h = U + Pv then:
J
W by = W turb = ∆h
C. Turbine Power
o
Turbine power = Mstm ∆h
o
Turbine power = Mstm (hstm - hexh)
D. Property and Parameter Changes
1. Enthalpy decreases
2. Velocity unchanged

16

11142678
3. Pressure decreases
4. Temperature decreases
5. Specific volume increases
6. Entropy increases for real turbine; constant for ideal
E. Plot turbine on Mollier Diagram Real and Ideal
NOTE: For Real turb. must know h or % M to get work, Ideal assume const.
entropy
F. Turbine efficiency
1. In Ideal Turbine there will be a larger ∆h for a given pressure drop
2. The ∆h for the real turbine working between the same two pressures will
be smaller. Due to losses in the turbine Entropy increases indicating
some of the steam energy has become unavailable for conversion to
work.
3. Turbine efficiency
a) ηturb = Wturb real = ∆h real
Wturb Ideal ∆h ideal
b) Typically the turbine is designed to be most efficient at full load 85%
- 92%
G. Example:
Given: Inlet conditions; 900 psia
o

Msteam = 5 x 105 lbm/hr


Outlet conditions; 1 psia, 28% moisture

17

11142678
Find: Real Turbine power in HP and KW
Ideal turbine power in HP
Turbine efficiency
0
P turb Real = Mstm (hstm - hexh)

5 x 105 lbm/hr (1195 BTU - 815 BTU) = 74.8 x 103 hp


2.54 x 103 BTU/hr-hp
or = 55.9 x 103 KW
or = 3.4 x 103 BTU/hr-KW
P turb Ideal = 5 x 105 lbm/hr (1195BTU-781 BTU)= 81.5 x 103 hp
2.54 x 103
ηturb = 74.8/81.5 = 91.7%

18

11142678
ATTACHMENT 1

1. What happens to each one of the following parameters as the diameter of


a pipe gets smaller (increase, decrease or stay the same)?
1.1 Enthalpy
1.2 Entropy
1.3 KE
1.4 PE
1.5 Work

2. A pump takes suction on the hotwell at 28" vac. & 107o F and discharges
at a pressure of 350 psia. Pump flow rate is 1 x 107 lbm/hr. What is the
pump work? (In HP) Assume suction is a Saturated liquid.

3. Given the following:


Psm: 1000 psia
o

M - 14 x 106 lbm/Hr
Pcond - 28" Hg Vac
Turb. Exit Quality = 83%
What is ideal Turb. work, real turb work and turbine efficiency?

4. EXTRA:
A pump has a ∆h = 3 btu/lbm. If the pump head is 500 psi, how much of the ∆h is
due to ∆u? (Inlet temp. = 370°F)

19

11142678
5. Given the following conditions:
• NC press = 2235 psig
• PRT press = 0 psig
• NC-32 (PORV) Leaking by.
Find the following for the downstream fluid:
5.1 Phase
5.2 Temp.
5.3 Quality
5.4 Entropy
5.5 Enthalpy

6. A 'C' HTR DRN Pump takes suction on the 'C' HTR DRN tank at 5 x 106
lbm/Hr. SUCT pressure is 1 psig and discharge pressure is 650 psia.
The suction temp. is 210o F. What is pump horsepower?

20

11142678
ANSWERS

1.
1.1 ↓
1.2 ↑
1.3 ↑
1.4 →
1.5 →

2. 28" = 1 psia
107°F v = .016155 ft3/lbm
o
m = 10 x 106 lbm/Hr
Wk = 10 x 106 lbm/Hr (.016155 ft3/lbm) (349 lb/in2) (144 in2/ft2)
= 8.11 x 109 ft-lbf/hr (1 hr/3600 sec.)(.0018182 ft - lbf sec)
HP
•••••••••••
= • 4100 HP •
•••••••••••
o o

3. WkI = M (∆h) WkR = M ∆h

= 14 x 106 lbm/Hr (1192.9 - 775) = 14 x 106 lbm/Hr(1192.9 - 930)


= 5.85 x 109 BTU/Hr = 3.67 x 109 BTU/Hr
η = WkR/WkI

= 3.67 x 109 = 62.9%


5.85 x 109

4. ∆h = ∆u + ∆Pv
3 BTU/lbm = ∆u + (500 lbf/in2) (144 in2/ft2)(.01824 ft3/lbm)
778 Ft-lbf
BTU
21

11142678
3 BTU/lbm = ∆u + 1.688 BTU/lbm
1.31 = ∆u

5. h = ~1118 BTU’s
phase = Wet Vapor
Temp = 212°F
X = 97%
S = 1.71

6. Wk = 5 x 106 lbm/Hr (634 lb/in2)( 144 in2/ft2 ) (.0167 ft3/lbm)


= 7.6 x 109ft-lb/Hr (1 Hr/3600 sec.) (.0018182 ft - lbf sec)
HP
= 3850 Horsepower

22

11142678
REVIEW OF THERMODYNAMIC
PROPERTIES (3)

11142678
OVERVIEW
This lesson is a review of the principles and applications of fluid flow. Discussion will
include pumps and pump operation for forced fluid flow.

1. REFERENCES:
1.1 Introduction to Thermodynamics; Kurt C. Rolle
1.2 Pump Handbook; Karassik, Krutzsch, Frasser, Messina

11142678
TERMINAL OBJECTIVE
At the end of this lesson the student will have a working knowledge of the principles
and applications of fluid flow. He will also understand pumps and pump operation for
forced fluid flow.

ENABLING OBJECTIVES

1. Define the following:


1.1 Head Loss
1.2 Friction

2. Explain how a change in each of the following will affect friction Head
Loss.
2.1 Friction Factor
2.2 Pipe Length
2.3 Pipe Diameter
2.4 Fluid Velocity

3. Describe the two types of flow that can occur in a system:


3.1 Laminar
3.2 Turbulent

4. Explain the purpose of a pump.

5. Explain the theory of operation for a centrifugal pump.


5.1 Define pump head.
5.2 Explain how flowrate, head, and power vary with pump speed.

6. Define NPSH available and NPSH required.

7. Define Cavitation.
7.1 List the conditions and parameters that affect cavitation.
7.2 Explain how cavitation is detected.
7.3 Explain how cavitation is prevented or stopped.

11142678
8. Define pump runout.
8.1 Explain the problems associated with runout.
8.2 Explain plant design features that limit runout.

9. Define pump shutoff head.

10. Explain the theory of operation of a positive displacement pump.


10.1 Explain how to vary the capacity of a positive displacement pump.
10.2 Explain how a Pd pump is affected by cavitation and runout.

11. Define "water Hammer"

11142678
LESSON OUTLINE

1. INTRODUCTION
1.1 Overview
1.2 Objectives

2. PRESENTATION
2.1 Fluid Flow
2.2 Headloss

3. PUMPS AND PUMP OPERATIONS


3.1 Centrifugal Pumps
3.2 Series and Parallel pump operations.
3.3 Closed System pump Operation
3.4 Open System Pump Operation
3.5 Positive Displacement Pumps

4. PLANT PROBLEMS
4.1 Water Hammer

11142678
1. INTRODUCTION
1.1 This lesson will discuss: Fluid flow, factors affecting fluid flow, pumps and pump
operation.
1.2 Cover appropriate objectives.

2. PRESENTATION
2.1 Fluid Flow
A. Definition: Fluid flow is the movement of a fluid from one point to another in
a system.
B. Development of Fluid Flow.
1. No flow can be developed within a system until a driving force is
established.
2. This difference in pressure (the driving force) can be created by two
methods:
a) By a pump
b) By a difference in density of a fluid.
3. Recall that the energy balance performed on the straight pipe showed
that energy conversions took place between points one and two.
4. Remember that P1V1 > P2V2 and U2 > U1V, where V is the specific
volume. The change in pressure between the two points (Delta P), or
differential pressure, resulted due to the flow of fluid within the pipe.
5. The pressure loss in the pipe was a conversion of flow energy (Pv) to
internal energy (U) caused by the friction between the fluid and the pipe
wall. This conversion is called Headloss.
6. Friction is the resistance to movement.
2.2 Headloss
A. Definition: Headloss is the conversion of flow energy to internal energy due
to friction.
B. Headloss (HL) is dependent on any factor in a piping system which will
change or vary the amount of friction in that system.

11142678
C. The factors that affect headloss are:
1. Pipe length: as the length of pipe increases, headloss will increase.
2. Friction factor: as the roughness of the pipe increases or the viscosity of
the fluid increases; the friction, headloss and pressure drop will
increase.
3. Fluid velocity: as the fluid velocity (squared) increases, the friction,
headloss and pressure drop will increase.
4. Pipe diameter: as the pipe diameter increases, the friction, headloss
and pressure drop will decrease.
D. An equation is used to illustrate the terms affecting headloss and is known
as Darcey's equation:
1. hL = FLV2 where: F is the friction factor
D 2 gc L is the length of pipe
V2 is the fluid velocity squared
D is the pipe diameter
2. When a system is designed, built and then operated, the hL equation
becomes:
hL = KV2
2gc
Because F, L, D are constant, the constant k is substituted and HL is
proportional to the V2. The velocity of the fluid will have a direct effect
on the type of flow in the pipe.
E. Operators have some control over system headloss in the following ways.
1. Valve position changes will change the friction felt by the fluid and the
velocity of the fluid.
2. Changing the system lineup by adding more components or removing
components also changes the friction factor.
3. Varying the speed of a single pump or the configuration of several
pumps within the system will vary the velocity term.

11142678
F. There are two categories that flow will fall into. One type results in low
headloss and another type causes high amounts of headloss.
1. Laminar flow - this is fluid flowing in layers and occurs in low flow
systems (v < 10 ft/sec.)
a) In this type of flow, layers of fluid near the pipe wall covers the
roughness of the pipe wall. As far as headloss is concerned, this will
reduce friction, headloss and the pressure drop.
b) One problem with laminar flow is that the layers of fluid act like
insulation and reduce the heat transferred into or out of the fluid.
2. Turbulent flow - this is fluid flowing with random motion in the system.
(v >12 ft/sec)
a) This type of flow creates more friction between the molecules
themselves and between the water molecules and pipe wall.
Because of increased friction, the headloss and pressure drop
increase.
b) One advantage to turbulent flow is that the random mixing action of
the fluid will enhance the heat transfer process.
c) Friction is related to the type of flow in a pipe through Reynolds
number (R#). R# is related to velocity: as v ↑ --> R#↑
R# = Vav D R# is unitless
v Vav = average velocity v = viscosity
D = pipe diameter
For R# < 2000 the flow is Laminar. From 2000-3000 the flow is in
Transition. For R# > 3000 the flow is turbulent.

3. PUMPS AND PUMP OPERATIONS


3.1 Centrifugal Pumps
A. Principle of Operation - As Fluid enters the suction of the pump, it undergoes
a pressure drop. The impeller then increases the velocity of the fluid as the
fluid moves along the impeller vanes. The fluid also sees an increase in
area which will convert some of the velocity to pressure (A↑ → v↓ → p↑ ).
The fluid then passes into the volute where the rest of the velocity increase
from the impeller is converted to pressure by another area increase.
B. Characteristics
1. For a given speed the pump head will decrease as volume flow rate
increases. (Where pump head = discharge press - suction pressure)

11142678
2. Centrifugal Pump Laws

a) The change in V α the change in speed. ( ∆V α ∆N)
• •
V1 / V2 = N1 / N2
where: N = speed or RPM

V = ft3/time
b) The change in pump head α the change in pump speed, squared.
( ∆Hd α ∆N2)
2 2
Delta P1 / Delta P2 = (N1) / (N2)
where Delta P = pump head (psid or ft of water)
Pump head = Disch press - Suction Press.
c) The change in pump power is α the change in pump speed, cubed.
( ∆P α ∆N3)
3 3
P1 / P2 = (N1) / (N2)
where: P = power
d) Example: Given; variable speed pump at 2000 RPM
Delta P = 250 psid, V = 3000 gpm, P= 5000 HP
Find V, Delta P, and P at a speed of 4000 RPM
1) V α N;
V1/V2 = N1/N2

V2 = (N2/N1) V1 = (4000/2000) 3000 gpm = 6000 gpm

2) Delta P α N2
2 2
Delta P1 / Delta P2 = (N1) / (N2)
2 2
Delta P2 = [(N2) / (N1) ] Delta P1
2 2
Delta P2 = [4000 / 2000 ] 250 psid

Delta P2 = 1000psid

3) ∆PWR α N3
3 3
P1 / P2 = (N1) / (N2)
3 3
P2 = [(N2) / (N1) ] P1

11142678
3 3
P2 = [4000 / 2000 ] 5000 HP
P2 = 40000 HP
3. Series and Parallel Pump Operation
a) Series Configuration
Consider a condensate and feed system. Imagine a single pump
that takes a suction on the hotwell and pumps it to the boiler. The
pump must create enough Delta P to overcome the headloss
associated with the components in the system plus the difference in
pressure from the condenser to the boiler. This job would require a
pump with many stages. The option is to design a system with
more pumps in series. Each pump will create a Delta P to
overcome headlosses and provide suction pressure for the next
pump in the system.
1) Each pump has its own characteristic curve, each produces
some head for a given volume flow rate.
2) When placed in series, the first pump increases the pressure in
the system. The discharge of pump #1 is now the suction line
to #2 pump which will also create its own Delta P. Since the
pumps add their pressures independently, the total or combined
head curve is merely the addition of pumps 1 and 2.
3) In series pump operation, the capacity for flow is no greater
than the capacity of one pump.
4) In an operating system, the characteristic curve for that system
has not changed but the operating point (the intersection of the
pump and system curves) has. The increased pump head
creates higher volume flow rate. Higher volumetric flow rate (V)
in turn creates more headloss and shifts the operating point up
the system characteristic curve.
5) The above explanation is the same as describing the operation
of one multistage pump where each stage is an individual
pump.
b) Parallel Configuration
In order to increase the flow capacity of any system, additional
pumps are added in parallel. This is done instead of using one
variable speed pump to reduce power consumption. ( ∆P α ∆N3)
1) Each pump has its own characteristic curve, each produces
some head for a given volume flow rate.

10

11142678
2) When placed in parallel, each pump draws suction from the
same point and discharges to another common point. Since
each pump sees the headloss of the system the Delta P of each
pump is not additive as it is in series configurations.
3) The total capacity of both pumps will be the addition of both
pumps flow rate.
4) Adding the second pump in parallel causes the fluid to
accelerate thus the headloss increases. We see an increase in
volume flow rate and a small increase in head of the pumps at
the new operating point.
5) Note the increased pump head for the second pump addition.
Generally the increase in pump head is limited by the maximum
head of the largest of the two pumps.
6) This design is desirable for high volume flow requirement where
the Delta P is less of a concern.
C. Problems
1. Cavitation
a) Definition - cavitation is the formation of vapor voids in the low
pressure area of the pump followed by their collapse in the high
pressure region.
b) Cavitation is caused by insufficient pressure available at the suction
of the pump.
2. Net Positive Suction Head
a) Net positive suction head available is the absolute pressure at the
suction of the pump minus the vapor pressure of the fluid at the
same point.
b) Required NPSH - required amount of pressure above the vapor
pressure necessary to prevent cavitation for some given volume
flow rate (V). This pressure will be equal to the pressure drop in the
pump from the inlet flange to the eye of the impeller. It is
determined at the factory and will be plotted on the pump curves.
c) Example: Instructor make up example for NPSH-Available
d) Results of cavitation
1) Pitting and subsequent erosion of impeller
2) Flow oscillations
3) Pump vibration
4) Overheating

11

11142678
e) Indications
1) Vibration and noise
2) Motor current fluctuations
3) Fluctuations in discharge pressure and/or flow rates.
f) Prevention Methods
1) Head tank to create a static pressure at pump suction.
2) Booster pump to increase pressure to suction of next pump.
3) Large suction pipe to convert KE to pressure increase.
4) Subcooled liquid to raise NPSHA (lower vapor pressure).
5) Pressurize entire system.
6) Close down on discharge valve - this will decrease fluid velocity
and reduce the pressure drop in the pump and thus reduce the
required NPSH.
3. Other centrifugal pump problems
a) Pump Runout - the maximum flow rate at the lowest anticipated
system head for a given system design and pump selection. Pumps
which operate in an oversized system can reach their maximum flow
rates because of not enough system headloss.
Correctly sized pumps can reach runout due to ruptures in the
system which drastically reduces or eliminates headloss. Pumps
running in parallel may runout if one pump trips.
1) Results
(a) Pump efficiency decreases
(b) Eventual flow loss (possible cavitation problems)
(c) Overheat motor and/or pump
2) Prevention methods
(a) System design - choose correct pump for system.
(b) Throttle discharge to prevent high flow rates.
(c) Create some minimum static head the pump must
always discharge against.
b) Pump Deadhead - pump is running with little or no flow.
1) Results
(a) Overheat pump and/or motor.
(b) Efficiency is very low

12

11142678
(c) So much heat put into water (W p) that temperature will
increase; therefore, a greater pressure is required to
prevent cavitation.
2) Prevention Methods
(a) Supply a flow path which will produce the manufactured
suggested minimum safe flow rate. (i.e. recirc line)
3.2 Positive Displacement Pumps
A. Principle of Operations - the pump is usually a reciprocating piston device
which draws the fluid into a chamber on one stroke and then compresses
the trapped fluid before releasing it into the system.
B. Types of Positive Displacement Pumps
1. Reciprocating
2. Rotary
3. Screw
C. Characteristics
1. For a given speed, the volumetric flow rate is constant. Ideally, the
volume flow rate will not vary (for that speed) until the mechanical
leakage increases when the pump operates at extremely high discharge
pressures.
2. The head (discharge pressure minus suction pressure) is dependent on
the system the pump discharges into.
D. Problems
1. Cavitation
a) A positive displacement pump will cavitate and the results,
indications, and prevention are basically the same as for a
centrifugal pump.
2. Runout
a) A PD Pump will not suffer runout.

4. PLANT PROBLEMS
4.1 Water Hammer
A. Defined as a force wave of fluid striking an obstruction in a pipe (e.g. closed
valve, abrupt turn)
B. Causes
1. Starting a pump with the discharge valve open.

13

11142678
2. Initiating flow in an unvented system.
3. Rapidly closing a valve with flow in the line.
C. Effects
1. Causes rattling in pipes.
2. Loud Noise.
3. Damage to piping, hangers, components.
D. Prevention
1. Always initiate flow in an unvented, unfilled system slowly.
2. Use good sense and judgement when starting pumps and
opening/closing valves.

14

11142678
REVIEW OF THERMODYNAMIC

PROPERTIES (4)

11142678
OVERVIEW:
This lesson plan discusses the concept of Thermal Efficiency and the methods
employed to maximize efficiency..

1. REFERENCES:
1.1 Elements of Applied Thermodynamics: Johnson, Brocket,
1.2 Brock, Keating: Naval Institute Press.

11142678
TERMINAL OBJECTIVE
At the end of this lesson the student will understand the concept of Thermal Efficiency
and the methods employed to maximize efficiency..

ENABLING OBJECTIVES

1. Define Thermal Efficiency and discuss its relationship to the heat and
work in a Thermodynamic Cycle.

2. Discuss the Rankine Cycle in terms of the processes involved, and the
component corresponding to each process.

3. Discuss the effects of the following on Thermal Efficiency:


3.1 Feedwater Heater Operation
3.2 Condenser Pressure
3.3 Condensate Depression
3.4 Turbine Load

11142678
LESSON OUTLINE

1. INTRODUCTION TO POWER PLANT CYCLES


1.1 Purpose of the lesson

2. PRESENTATION
2.1 Power Cycles
2.2 Thermal Efficiency and the Second Law
2.3 Rankine Cycle
A. Elements of the Cycle
B. Cycle Efficiency
2.4 Design Improvements In Efficiency
A. Feedwater heating
2.5 Operational Effects on Efficiency
A. Condenser Pressure
B. Condensate Subcooling
C. Throttling
D. Operating Power Level
E. Other Considerations
F. Indications of Changing Efficiency

11142678
1. INTRODUCTION TO POWER PLANT CYCLES
1.1 Purpose of this lesson
A. Define Power Cycles
B. Tie individual components discussed previously into the plant
C. Develop the concept of Thermal Efficiency, discuss the conditions which
effect it.
1. Design
2. Operational

2. PRESENTATION
2.1 Power Cycles
A. Definition
1. A Thermodynamic Cycle is a recurring series of thermodynamic
processes used for transforming energy into a useful effect.
2. For a power cycle the energy is in the form of heat and the useful effect
is mechanical work.
B. Elements of the Thermodynamics Cycle
1. A working substance
a) Acts as the medium for transport of energy through the cycle.
b) Steam/water is the working substance in power cycles.
2. An engine
a) The device where thermal energy of the working substance is
converted to mechanical work.
b) The steam turbine is the engine for power cycles we will be
discussing.
3. A source or high temperature energy reservoir
a) Supplies energy as heat to the working substance
b) The boiler furnace and the fuel supplied provides the heat source.
4. A sink or low temperature energy reservoir
a) Absorbs energy as heat from the working substance either directly
or through an intermediate heat transfer device known as a receiver.
b) The lake, river, ocean, cooling towers, etc will be the sink.
c) The Condenser is a receiver.

11142678
5. A pump - moves the working substance from the low pressure region of
the cycle to the high pressure region.
C. More elements or components may be introduced into the cycle in order to
improve performance, as we will see later.
2.2 Thermal efficiency and the second law of thermodynamics
A. For a work producing cycle the thermal efficiency (η) equals the output
divided by the input.

1. η = OUTPUT
INPUT
2. For a cycle where heat is converted to work.

η = Net work out


Heat Input
B. Applying the first law of thermo to the basic cycle.
1. Energy Balance
a) Energy into cycle = Energy out of the cycle.
b) Qadded = Work out + Qrejected
rearranging; Work out = Qadded - Qrejected
2. Thermal efficiency can be expressed as:
η = work out
Q added
substituting for Work out:
η = Qadded - Qrejected
Qadded
3. The first law does not restrict how the energy conversion takes place nor
to what extent.
C. The Second law of Thermodynamics
1. Early efforts to increase the cyclic work produced from a given heat
input by reducing the heat rejected suggested the possibility of reducing
this waste. This led to the Second Law.
2. No engine, actual or ideal, when operating in a cycle can convert all the
heat supplied it into mechanical work.
D. The Carnot Cycle

11142678
CARNOT CYCLE

A B
TH
TEM PERATURE

TL D C

S1 S2
ENTROPY

15

1. Used here to illustrate the basic relationships which effect cycle


efficiency.
a) Most efficient cycle conceivable though not practical.
b) Serves as a standard of comparison for all heat cycles in use today.
2. Composed of four reversible thus ideal processes.
a) Constant temperature heat addition.
1) Heat is added to the working fluid at the source temperature
from a to b.
2) The heat added is the area under the a-b Process line on the T-
S Plot. (T∆S1-2)
b) Isentropic expansion from b to c gives the work output
c) Constant temperature heat rejection from c to d.
1) Heat is transferred from the working fluid at the sink
temperature
2) The heat rejected in the area under the c to d process line on
the T-S Plot. (Tsink∆ S2-1)
d) Isentropic compression from d to a.
3. The work produced by the cycle is the difference between the heat
added and the heat rejected. Area a b c d on the T-S plot.

11142678
4. Cycle efficiency
a) Efficiency Relationship

work ! added − Q
Q ! rejected
1) η = ! = ! added
Qadded Q
!
2) Recall that Q added = Tsource ∆S1-2
!
Q rejected = Tsink ∆S2-1
3) Substituting and dividing out ∆S
Tsource − Tsink
η=
Tsource
 Tsink 
η= 1−  
 Tsource 
b) Means of increasing Carnot Efficiency

INCREASE CARNOT • INCREASE TEMP FOR


HEAT ADDITION.
CYCLE EFFICIENCY ?
INCR. WORK w/o
INCREASING Qrej.
• APPLICATION:
TH HIGHER Tave
TEM PERATURE

SUPER HEAT
MSRs
FW HEATING
TL LIMITS ON MATERIALS
• DECREASE TEMP FOR
HEAT REJECTION.
S1 S2 LIMITED BY SINK TEMP
ENTROPY

22

1) Increase the temperature at which heat is added


(a) Increases the work out without increasing Q rejected.
(b) This concept has application in the real world
• Raising Temperature
• Using superheat
8

11142678
• Feedwater heating
(c) Constant temperature heat addition is not possible with
real working fluids resulting in a sacrifice of work.
Example is preheat to sat. temp. of feedwater.
2) Reduce the temperature at which the heat is rejected
(a) Lowers Qrejected for a given Qadded with a
corresponding improvement in workout.
(b) This principle is limited by the available heat sink such as
lake temperature.
2.3 The Rankine Cycle
A. Elements of the Cycle
1. Represents the simplest steam cycle. Serves as the starting point for
further refinements.
2. Working fluid - Water in the vapor and liquid phases.
TEMPERATURE

a1 b

c
d

ENTROPY

RANKINE
CYCLE 24

3. Heat addition in the Steam Generator.


a) Subcooled liquid from the pump discharge enters the boiler at boiler
pressure. (Point a)
b) A portion of the heat added to the feedwater goes to raising the
temperature to saturation (point a1)

11142678
c) The majority of the heat added goes to vaporizing the liquid
(constant temperature) from Point a1 to b.
d) The heat added per lbm. in the boiler is:
q = hsteam − hfeed
e) The average temperature at which the heat is added during the pre-
heat portion is lower than during vaporization which results in a
lower efficiency than the carnot cycle.
4. Expansion in the Turbine
a) Ideal turbine b to c
1) Constant entropy expansion to condenser pressure
2) Enthalpy is converted to work
work per lbm = hsteam − hfeed
3) Wet vapor is exhausted to the condenser.
b) Real turbine b to c.
1) Losses due to throttling, moisture, friction etc. result in less of
the energy being converted to work
2) Entropy increases from inlet to outlet
3) Exhaust enthalpy for the real turbine at the same pressure is
higher than the ideal turbine indicating:
(a) Less work per lbm
(b) More heat rejected per lbm
(c) Lower cycle efficiency
5. Heat Rejection in the Condenser
a) Wet vapor at condenser pressure enters the condenser.
b) The heat is rejected to the cooling water, condensing the steam, c to
d.
c) The heat rejected per lbm. is:
q = hexh − hcondensate
6. Pump-d to a
a) Constant entropy compression
b) Raises the pressure from condenser pressure to boiler pressure.

7. Superheat/reheat brings the energy of the fluid


back to a high level for use in the turbines.
10

11142678
Superheat
TEM PERATURE

ENTROPY

REHEAT CYCLE
31

2.4 Cycle Efficiency


A. Feedwater Heating
1. Principle of Feedwater heating
a) A portion of the steam flow is extracted from the turbine after
expanding through several stages.
b) The extracted Steam Condenses in the feedwater heater
c) The heat of condensation is transferred into the feedwater returning
to the Steam Generator.
d) The drains from the feed heaters are returned to the feedwater
system by the drain pumps.
2. Effect of Feedwater heating is improvement of the cycle efficiency
a) Raises the average temperature of heat addition in the steam
generator.
1) Feed heating raises the temperature from a to a1
2) Heat from the reactor is added from a1 to b.
3) A larger portion of the heat is added at a higher temperature,
improving efficiency.

11

11142678
b) Less heat rejected
1) Some of the energy in the steam is recirculated into the
feedwater rather than being rejected in the condenser.
2) This results in less total steam flow through the turbine but the
effect improves efficiency.
2.5 Operational Effects On Efficiency
A. Condenser Pressure

OPERATIONAL EFFECTS:
CONDENSER PRESSURE

! LOWER ABSOLUTE PRESSURE


! LOWER AVERAGE TEMPERATURE FOR
HEAT REJECTION
! LARGER DELTA h PER lbm STEAM
TEMPERATURE

ENTROPY

35

1. Lower condenser pressure (higher vacuum) in general yields improved


efficiency.
a) Lower pressure means lower temperature at which the heat is
rejected. (The condenser is at saturation conditions)
b) A larger portion of the steam enthalpy is converted to work.
c) Less heat rejected.
2. Condenser Pressure is affected by:
a) Condenser Cooling Water flow rate - lower flow rate yields higher
condenser temperature and pressure
b) Condenser Cooling Water inlet temperature - higher temperature
yields higher condenser temperature and pressure.

12

11142678
c) Condenser heat load - higher steam flow rate into the condenser for
a given Condenser Cooling Water inlet temperature and flow rate
causes higher Condenser Cooling Water average temperature and
condenser to Condenser Cooling Water ∆T. Condenser
temperature and pressure will be higher.
B. Condensate subcooling (condensate depression)

OPERATIONAL EFFECTS:
CONDENSATE SUBCOOLING

"EXTRA HEAT ADDITION REQ’d


"EFFICIENCY REDUCED
"REQ’d FOR PUMP NPSH
! CNS DESIGN MINIMIZES
TEMPERATURE

ENTROPY

36

1. Condensate depression occurs when the heat rejected exceeds heat


which is required to condense the exhaust steam from the turbine
resulting in subcooling of the condensate.
2. The extra heat rejected must be replaced by the heat source.
3. Efficiency is reduced.
4. Some subcooling may be desirable in order to provide NPSH for the
Hotwell pumps.
C. Throttling
1. Throttling the steam flow prior to admission to the turbine reduces
efficiency.
a) Throttling is constant Enthalpy.
b) Turbine inlet pressure is lower
c) Less of the enthalpy is converted to work in the turbine in
exhausting to the same condenser pressure

13

11142678
d) The throttling loss eventually shows up as increased heat rejected.
2. Operational Considerations
a) Sequential operation of governor valves
b) Operation with governor valves fully open at full power if possible.
D. Superheat and Reheat

e
TEMPERATURE

a1 b

c f
d

ENTROPY

RANKINE
CYCLE 25

1. Superheat and reheat adds temperature and energy to the cycle.


2. It also has the effect of increasing the quality of the fluid.
E. Operating Power Level
1. In general, the plant is more efficient at full load then at lower power
levels.
a) Turbine is designed to be most efficient at full load.
b) Less throttling losses.
2. Increasing power level thus total steam flow can cause reduced
efficiency if corrective action is not taken.
F. Other methods of maintaining maximum efficiency.
1. Minimize auxiliaries
2. Fix steam leaks

3. Fix air leaks into condenser


14

11142678
4. Operation of SJAE condenser.

15

11142678
11142678
REVIEW OF THERMODYNAMIC

PROPERTIES (5)

11142678
1. OVERVIEW
This lesson covers the various modes of heat transfer and the equations used with
each mode. It gives an introduction to nucleate boiling and the factors affecting DNB.
A discussion of natural circulation and a brief discussion on heat exchangers is also
covered.

11142678
OBJECTIVES

1. Define 'Heat Transfer'.


1.1 State the three ways heat is transferred in a power plant.

2. Define 'Conduction' heat transfer.


2.1 Explain the variables that effect the rate of conduction heat transfer.
2.2 List the formulas used for conduction heat transfer.
2.3 Give an example of where conduction heat transfer occurs in the power plant.
2.4 Given a set of parameters, be able to work conduction problems.

3. Define 'Convection' heat transfer.


3.1 Explain the variables that effect the rate of convection heat transfer.
3.2 List the formulas used for convection heat transfer.
3.3 Give an example of convection heat transfer in the power plant.
3.4 Given a set of parameters, be able to work convection problems.

4. Define 'Radiation' heat transfer.


4.1 Explain the variables that effect the rate of radiation heat transfer.
4.2 Give an example of radiation heat transfer in power plant.

5. Explain why a counter flow heat exchanger is the most efficient type of
heat exchanger.
5.1 Using the appropriate heat transfer formulas and given information, be able to
work heat exchanger heat transfer problems.

11142678
OUTLINE

1. INTRODUCTION

2. PRESENTATION
2.1 Heat
2.2 Conduction
2.3 Convection
2.4 Natural Circulation
2.5 Radiation Heat Transfer

3. HEAT EXCHANGERS
3.1 Heat Transfer in Heat Exchangers
3.2 Types of Heat Exchangers
3.3 Applications

4. SUMMARY

11142678
1. INTRODUCTION
This lesson will present the topic of heat transfer including the 3 modes of heat
transfer, natural circulation, and heat exchangers.

2. PRESENTATION
2.1 Heat- Energy transferred between two substances due to a temperature
difference.
A. Rate of Heat Transfer (Q) - Energy/unit time (BTU/hr)
B. Heat is transferred by three methods
1. Conduction
2. Convection
3. Radiation
2.2 Conduction - transfer of heat thru a material due to a Delta T across the material.
It involves no motion of the material itself, but is a result of collisions between
the molecules of the material.
A. Thermal Conductivity (k) - the rate of heat transfer between opposite faces
of a unit cube of material with a Delta T = 1°F. (BTU/hr - °F- ft.) "k" varies
with the type of material and temperature range. The larger the value of k,
the better a material will conduct heat
B. As the feedwater enters the lower boiler drum it is delivered up the inside of
the boiler wall tubes. In these tubes the water conducts the heat trough the
boiler tube walls from the heat input from the boiler furnace. The water, as it
turns to steam, goes to the steam drum..
C. Conduction through a material can be calculated by:
Q = K A Delta T
Delta X
Where K = thermal conductivity
A = Area
Delta T = Temperature difference
Delta X = Material thickness
D. If there are several materials together, such as through a heat exchanger
tube, the rate of heat transfer is a result of all the k's, A's, Delta T's, and
Delta X's for the materials.

11142678
E. To simplify working with conduction problems, the terms k and Delta X have
been combined to give the term "overall heat transfer coefficient"
(U = BTU/hr- oF - ft2) and results in the formula:
Q = UA Delta T
(U also includes another variable to be discussed in convection heat
transfer.) Used anytime heat is transferred across a material and the 'U' and
'A' terms are known. In the power plant it is used in problems relating to the
boiler tubes, condenser tubes, Hx tubes, etc.
2.3 Convection - transfer of heat energy by the combined action of conduction,
energy storage, and mixing motion of a fluid between regions of high and low
temperatures (i.e. the energy transfer between a surface and a flowing
substance).
If the fluid is being pumped, we have forced convection. If flow is due to a
change in the fluid density, we have natural convection.
A. The rate of heat transfer (Q) due to convection will be dependent on several
properties of the fluid, such as; temperature, velocity, specific heat, viscosity,
etc. These variables have been combined into one factor called the Nusselt
Number (Nu). Also affecting Q are the thermal conductivity and the length of
fluid being observed. To further simplify this, another factor has been used
to combine all of these variables; Convection Heat Transfer Coefficient.
hc = Nu K
L
This term is also included in the U term of Q = UA Delta T.
Looking back at this formula for a moment, we see that we can increase the
Q by doing three things:
1. Increase the Delta T (not desirable)
2. Increase the A (set by design)
3. Increase U (done by increasing hc)
Looking further, "U" can be increased by two methods: (1) decrease
laminar layer or (2) break up the laminar layer
B. Reheat and superheat sections of the boiler use convection heat transfer.
The superheat section take the saturated steam from the boiler steam drum
and raises its temperature to the desired level. In this process any small
droplets of water carried out of the drum are also evaporated. The reheat
section takes steam exiting the HP turbine. This steam is piped back to the
boiler to the reheat section so that the energy of the steam and the quality of
the steam can be increased back to a superheat condition for use in the IP
and LP turbines.

11142678
C. The formulas used for convective heat transfer are:
1. Q = MC Delta T and,
2. Q = M Delta h
D. Uses
1. Q = M C Delta T
a) Used for heat transfer in medium with no phase changes and no
boundary is crossed.
2. Q = M Delta h
a) Used for heat transfer where there is a phase change, but no
boundary is crossed.
Example:
1) Feedwater to steam in the boiler
2) Steam to condensate in the condenser
2.4 Natural Circulation
A. Mechanism
1. Natural Circulation occurs due to density difference between fluids or
two points in the same fluid system. As a fluid is heated up its density
decreases. Fluids of higher temperature, lower density have a natural
tendency to rise to a higher elevation. Conversely, fluids with lower
temperature, higher density have a tendency to fall to a lower elevation.
a) Example
---------------Levels equal-------------
70 F 180 F

Tank 'A' water has a higher density than tank 'B' because of the
lower temp. Static pressure felt on either side of the valve will be
due to the difference in density between the tanks since there is no
height difference.
Flow will occur from tank 'A' to Tank 'B' until levels change
sufficiently to cause the Delta P = 0.

11142678
b) In the above example we could place a heater in tank 'B' and a heat
exchanger in tank 'A' to remove heat and we would still only get flow
until the levels changed to make Delta P = 0. To have continuous
flow between the tanks, a complete path from tank 'B' to tank 'A' and
a completely filled loop is needed. With the heat source (heater),
heat sink (heat exchanger), and return flow path, we can establish a
small natural circulation flow.

COOLING
FLOW HEATER
A B
(SINK) (SOURCE)

2. The amount of flow we can get from the above system can be aided
further by elevating the heat sink (tank 'A') above the source (tank 'B').
The difference in height will cause a greater Delta P, increasing flow.

HEIGHT

2.5 Radiation Heat Transfer - the emission of heat energy in the form of
electromagnetic radiation from a body by virtue of its temperature. Unlike
conduction and convection, radiation heat transfer is independent of any
medium and depends entirely on the absolute temperature of the radiating body.
The rate of heat transfer is still dependent on the Delta T between two bodies.
When conduction and convection cease due to loss of transfer medium radiation
transfer will be the only means of heat removal.
2.6 Types of Heat Exchangers
A. Counter Flow heat exchangers - In a counter flow heat exchanger the two
fluids flow in opposite directions. Because of this, the average Delta T is at
its maximum all along the tubes. This gives the maximum heat transfer of all
the heat exchangers.

11142678
B. Parallel flow - In parallel flow exchangers the two fluids flow in the same
direction. This results in a large Delta T at the inlet, with a small delta T at
the outlet. The heat transfer rate for a parallel heat exchanger is less than
for a counter flow heat exchanger of the same size.
C. Cross-Flow
1. In a cross flow heat exchanger, one fluid flows across the tubes. These
heat exchangers are of two types.
a) Single pass- fluid makes one pass at right angles
b) Multi-pass - fluid makes several passes back and forth across the
tubes to set up an approximation of counter flow.
2. The Main Condenser is a cross flow heat exchanger.

11142678
3. SUMMARY
3.1 Three methods of Heat Transfer
A. Conduction
B. Convection
C. Radiation
3.2 Cover Objectives

10

11142678
HEAT RATE IMPROVEMENT
REFERENCE MANUAL:
INTRODUCTION AND USE

11142678
1. OVERVIEW
1.1 This lesson will provide the student with an introduction to the ‘Heat Rate
Improvement Reference Manual’, the purpose, organization and use of the
manual.

2. REFERENCES
2.1 Heat Rate Improvement Reference Manual, Duke/Fluor Daniel

11142678
LESSON OUTLINE

1. Purpose

2. The Heat Rate Improvement Reference Manual


2.1 Heat Rate Primer
2.2 Heat Rate Logic Trees

3. Fossil Steam Station Components


3.1 Thermal Kits
3.2 Boilers
3.3 Turbine
3.4 Plant Auxiliaries
3.5 Condenser
3.6 Cooling Towers
3.7 Feedwater Heaters

4. Elements of a Thermal Performance Monitoring Program


4.1 Goals
4.2 Initial Steps for Establishing a Heat Rate Monitoring Program
4.3 Performance Tutorial
4.4 Performance Loss Monitoring and Trending of Key Parameters
4.5 Unit Performance Survey

5. Instrumentation and Testing Requirements for Heat Rate Monitoring


5.1 Instruments and Performance
5.2 Testing Program

6. Cycle Isolation

7. Heat Rate Improvement Program

8. Appendix A and B

11142678
TERMINAL OBJECTIVE

At the end of this class the students will have a working knowledge of the Heat Rate
Improvement Reference Manual.
ENABLING OBJECTIVES

1. At the end of this class the student will be able to:


1.1 State the purpose of the Heat Rate Improvement Reference Manual.
1.2 Define HEAT RATE.
1.3 Discuss the following in detail:
A. Design Heat Rate
B. Best Achievable Heat Rate
C. Actual Heat Rate
D. Factors Affecting Plant Efficiency
E. Controllable Losses
F. Accounted for Losses
G. Unaccounted for Losses

2. Read and interpret the logic trees, how to modify them for a particular
plant/facility and how to use them to develop decision criteria.

3. Discuss Thermal Kits.

4. Perform the following:


4.1 Loss calculations for various plant components including turbines, boilers,
condensers, cooling towers and feedwater heaters.
4.2 Set up thermal monitoring performance programs including:
A. Deciding upon which plant parameters to monitor
B. Determining deviations from expected values
C. Use of logic trees to identify possible causes of the deviations
D. Plan an appropriate course of action to resolve performance deviations.

5. Discuss short vs long term performance activities as follows:


5.1 Cycle Isolation Techniques

11142678
5.2 Improved Operation Practices
5.3 Preventive Maintenance Programs
5.4 Upgrades of Plant Instrumentation
5.5 Repair/Replacement of Components
5.6 Cost-Benefit.

11142678
1. PURPOSE - To define the performance standards necessary to
successfully manage a heat rate improvement plan. The information
contained in the manual can enable management , staff and technical
individuals to make their company more competitive and successful in the
future production of electricity.
1.1 The value of this is to measure how well the unit is doing its job in producing
electricity. Decisions should not necessarily be made only to improve
thermodynamic efficiency but rather to improve a company’s overall
performance.
1.2 A thermal performance program is actually the development of performance
parameters which characterize a unit’s operation.

2. The Heat Rate Improvement Reference Manual - (NOTE: all references


to figure numbers indicate figures located in the manual)
2.1 Heat Rate Primer
A. This chapter provides the user with definitions of heat rate
1. Heat rate - the amount of heat input into a system divided by the
amount of power generated by a system.
2. As-designed heat rate - a tool that provides a definable benchmark for
comparison and trending purposes. It is simply a curve generated from
turbine heat balance curves, unit expected auxiliary consumption and
design boiler efficiency.
3. Best achievable heat rate - the same as the net heat rate obtained
from unit acceptance test when the equipment was new and the unit
was operated at optimum. This heat rate value is realistic and attainable
for it has been achieved before.
4. Operating heat rate - calculated from the heat energy consumed by a
unit or station for a specified time period regardless of the operating
status of the unit or station.
5. Incremental heat rate - units within a utility system and within a power
pool are dispatched (loaded upon the grid) based on their incremental
heat rate and resulting cost curve. It is also used in production
simulation for maintenance planning and projecting fuel procurement
needs and for pricing of power for sale or resale.
B. A summary of heat rate measurement methods is also provided
1. Actual heat rate
2. Input/Output method

3. Output/Loss Method
6

11142678
C. Efficiency Factor - a quick reference of unit performance in relation to what it
was designed to be.
2.2 Heat Rate Logic Trees - a systematic approach to aid station engineering in
identifying the root cause(s) of declining unit performance
A. Heat Rate Losses Tree - used to identify areas in the plant where heat rate
degradation may be occurring without conducting expensive tests.
1. Structured to provide a process by which decisions can be determined
that narrow down the cause of the problem based on the available
information.
2. A statement of the problem starts the tree.
B. Major Cycle Component Tree - identifies major areas in the plant cycle that
have the potential for contributing to the overall problem.
1. Components such as boiler and turbine
2. Systems such as condensate/feedwater, cooling water,auxiliary systems
and fuel handling.
C. Logic Model Symbols.
1. “OR” gate - output occurs if one or more of the input events occur.

‘OR’ Gate

2. “AND” gate - output occurs if all of the input events occur.

11142678
‘AND’ Gate

3. “TRANSFER IN” - indicates that the logic model is developed further at


the occurrence of the corresponding transfer out. Transfers can be used
to simplify logic model construction by eliminating the need to develop
duplicate branches.

“TRANSFER IN”

11142678
4. “TRANSFER OUT” - denotes a transfer of a portion of the logic model to
corresponding transfer in. Transfer out symbol can correspond with
multiple transfer in symbols.

“TRANSFEROUT”

D. Logic Tree Application The engineer must first obtain data from various
sources at the station including routine monitoring of selected plant
performance parameters, special tests, outage reports, initial design
documents and interviews with plant personnel. He must then convert the
data into decision criteria and associate these with the appropriate areas of
the plant. (use figures 2-4 through 2-22 of the Heat Rate Improvement
Reference Manual to explain how the logic trees are used).

3. Fossil Steam Station Components


3.1 Thermal Kits - a collection of manufacturer turbine generator data in the form of
secondary cycle diagrams, curves, equations and constants. This data is
supplied to the purchaser in order to best describe the expected performance
characteristics of the turbine generator. (A sample thermal kit is supplied, but
specific plant data and thermal kits should be used if possible)
A. Purpose - the thermal kits are used primarily for the following functions:
1. Standards for monitoring
2. Data for cycle model verifications and studies
3. Unit net capability calculations

11142678
4. Turbine testing calculations
5. Corrected unit cycle heat rate or output computation
B. Details - the following covers the definition, explanation and applications of
the various items in thermal kits.
1. Heat Balance - a diagram of the unit’s secondary cycle describing the
expected conditions at a specific unit power level or at a valve point. The
cycle conditions described in a heat balance include:
a) enthalpies
b) absolute pressures
c) fluid temperatures
d) main steam quality
e) simplified normal cycle flow paths and flow rates
f) feedwater and condensate booster pumps enthalpy rises
g) gross generatoin
h) turbine heat rate
i) cycle expansion end points
j) fixed mechanical and electrical turbine generator losses
k) electrical generator conditions
l) calculation assumptions, units, steam tables used.
2. Turbine Heat Rate Curve - the heat rates and loads from the heat
balances are used to form the turbine heat rate curve. This expected
heat rate curve has been drawn through the locus of valve points.
3. Expansion Lines/Mollier Diagrams - the steam conditions during
expansion through the turbine are illustrated by a plot on a Mollier
diagram. The thermal kit expansion lines may be used as a basis for
comparison for test results and cycle model verification. If a test data
expansion line shifts to the right, there has been a decrease in eficiency
of that specific section.
4. Extraction Pressure vs. Flow - the extraction zone pressure is
determined by the turbine flow to the downstream stages. Either a graph
or equation is supplied that defines the expected Extraction pressure as
a function of turbine downstream flow for each extraction and for the first
stage shell pressure.
5. Enthalpies and End Points - expected stage, extraction and expansion
line end point enthalpies are plotted against flow by some venders.
These reflect the design at the turbine and its accessories.

10

11142678
6. Leakoffs - this data may be used for cycle models when no test data is
available. These may also be used as the baseline for comparison to
monitoring/trend results.
a) Control, Stop or throttle valve stems and packings
b) Turbine and gland steam seals
7. Exhaust Loss Curve - unrecoverable losses occur in the exhaust hood
of each LP turbine. The total exhaust loss is plotted as a function of
exhaust volumetric flow. The components are:
a) Leaving loss - the wasted kinetic energy of the steam leaving the
last stage.
b) Hood loss - results from the pressure drop of the steam passing
through the exhaust hood.
c) Turnup loss - occurs due to flow instabilities and recirculation found
at very low exhaust flows.
d) Shock wave pressure drop loss - due to the shock eaves formed at
the turbine exhaust when the pressure drop across the last stage is
greater than that required for sonic flow.
8. Choked (Limited) Condenser Pressure - each turbine generator unit has
a specific LP turbine exhaust pressure below which unit performance
starts to deteriorate, assuming steady flow and heat cycle conditions.
Choke limited pressure is nearly a linear function of turbine exhaust end
steam flow. Operation at a condenser pressure lower that the choke
limited pressure results in loss of net output and a higher heat rate.
9. Turbine Section Efficiency and Effectiveness - vender supplied curves
as a function of flow. These reflect expected performance. Turbine test
results are compared to these curves to determine which sections or
components have performance levels that deviate from the norm.
10. Electrical Generator Losses - the total generator loss is a function of
power factor, load, hydrogen purity and hydrogen pressure. This loss
information is used for calculating the turbine used energy endpoint in
order to calculate gross generation from cycle parameters.
3.2 Boilers -
A. Dry Gas Loss - high excess air and lower heat absorption in the boiler
system can cause exit gas temperatures higher than expected resulting in
Dry Gas Loss. A 40o F rise in exit gas temperatures can raise the Heat Rate
by one percent. High exit gas temperatures can be caused by:
1. Plugging or fouling of preheaters, hot or cold side where moisture has
formed due to reaching the dewpoint.

11

11142678
a) Ensure proper soot blowing for preheater.
b) Periodic high pressure washing may be necessary if the pressure
drop across the preheater starts to limit fan capablity.
2. Corroded or eroded Preheater. During the process of combustion, sulfer
in the fuel is converted to SO2 and, dpending on the excess air
available, part of the SO2 is converted to SO3. The SO3 reacts with any
water vapor to form sulfuric acid (H2SO4).
a) Ensure proper operation of steam coils or preheater bypass damper
to keep the preheater above the cold end minimum metal
temperature (Figure 3-2).
b) If steam coils are used, perform periodic inspections for leaks which
would increase water vapor to the preheater.
c) Open or close plant windows and doors to circulate outside air
through the plant and around the boiler to the Forced Draft fan
suction to minimize steam coil usage.
3. Inadequate boiler soot blowing can cause slag to build on heat
absorbing surfaces and proper heat transfer cannot occur.
4. Air Preheater average air in-gas out temperature too high above
dewpoint.
5. Incorrect number of pulverizer mills in service at a given load - causes
an increase in tempering air. This decreases the percentage of total air
flow which goes through the preheater, raising exit gas tempertures.
6. Excess pulverizer mill tempering air - causes low mill temperature.
7. Fuel/air control system - maintain O2 as low as possible without
adversely affecting combustion
8. Improper O2 monitoring system
a) Calibrate or repair monitors
b) Ensure location and quantity of monitors gives a representative
indication.
9. Air inleakage in boiler, preheater or ducts.
a) Run O2 rise test on boiler to locate air inleakage and make repairs.
b) O2 readings should be taken at several locations simultaneously to
isolate cause of air inleakage.
B. Dry Gas Loss Calculations (use Heat Rate Improvement Reference Manual’
section 3 along with actual plant data to perform calculations)

12

11142678
C. Unburned Carbon Loss - A flyash sample should be collected and analyzed
for unburned carbon. The percent unburned carbon is also called Loss On
Ignition (LOI). This can usually be traced to the following.
1. Improper excess air in the furnace
2. Poor mixing of the fuel and air in the furnace
3. Pulverized coal fineness is incorrect
4. High surface moisture in the coal can lead to agglomeration and have
the same effect as coarse coal during the combustion process.
D. Carbon Loss Calculations - (use Heat Rate Improvement Reference
Manual’ section 3 along with actual plant data to perform calculations)
E. Moisture Loss - Boiler efficiency calculations use the Higher Heating Value
(HHV) as the amount of heat generated in complete combustion of the fuel.
Since these losses are related to the percent moisture and hydrogen in the
fuel, improvements can only be made by minimizing the exit gas
temperatures discussed earlier.
F. Moisture Loss Calculations - (use Heat Rate Improvement Reference
Manual’ section 3 along with actual plant data to perform calculations)
G. Radiation and Unaccounted for Losses (RUMA)
1. Radiation losses account for heat losses to the air through conduction,
radiation and convection. The heat emanates from the boiler, ductwork
and pulverizers. If the unit is equipped with hot side precipitators, they
can be a source of significant gas temperature drop.
2. Unaccounted for losses include difficult to measure losses that are
included in a heat balance to arrive at a guaranteed efficiency. These
include heat lost in the ash leaving the furnace through the bottom ash
hoppers and economizer hoppers and any apparent losses due to
instrumentation errors.
H. RUMA Loss Calculations - (use Heat Rate Improvement Reference Manual’
section 3 along with actual plant data to perform calculations)

13

11142678
3.3 Turbine Steam is admitted through control valves to the turbine where the
thermal energy is converted to kinetic energy and then to mechanical energy by
expansion through the turbine sections. For maximum efficiency the turbine
stages contain a combination of impulse bucket and reaction blade designs. The
method used to control the steam flow to the turbine at various loads affects the
plant performance. Partial arc admission can be used where the control valves
are throttled successively which adjusts the active nozzle area and the throttle
pressure remains constant through the load range. In Full arc admission the
control valves remain fully open and the load is changed by varying the boiler
pressure or the boiler pressure can remain constant and all the control valves
are operated together until the desired load is reached. Usually the best
operation is a combination of fixed and variable pressure operation where the
control valves are throttled to a valve point and reduced pressure operation is
used in a particular load range. There are a number of factors dealing with the
turbine which can affect the unit heat rate.
A. Main Steam Temperature - A throttle temperature change can affect the
turbine load and heat rate. Curves supplied with the unit thermal kit are used
to estimate the effects of temperature deviations on the unit heat rate.
B. Main Steam Pressure - as with main steam temperature a change in
pressure can affect the unit load in several ways. The curve for calculating
heat rate improvements due to increased throttle pressure should be
included in the unit thermal kit.
1. A 5% increase in initial pressure will result in a 5% increase in steam
flow which in turn will cause a 5% unit load increase.
2. The increase in flow will cause an increase in steam velocity leaving the
last stage, increasing the total exhaust loss. An increase in exhaust loss
results in poorer low pressure turbine efficiency.
3. The throttle available energy increases as the pressure increases.
C. Design Features - Design considerations affecting turbine efficiency include
component design to minimize pressure drops, stationary and rotating blade
design to obtain optimum steam velocity, and section design to minimize
friction and leakage losses.
D. Maintenance Items - during maintenance outages all packing seals should
be inspected for wear and turbine blades and nozzles should be inspected
for corrosion or erosion.
1. Solid particle erosion (SPE) of turbine buckets and blades, nozzles and
control valves has been a problem of concern for many years. This
damage can be minimized by water chemistry, thermal cycling, materil
changes and elimination of air inleakage. Damage to turbine seals,
nozzles or blades can normally be detected from performing enthalpy
drop tests on the turbine quarterly.

14

11142678
2. Enthalpy drop test - (use ‘Heat Rate Improvement Reference Manual’
section 3 for discussion of this test, instrumentation required, Unit
operating setup, calculation and corrections)
3.4 Plant Auxiliaries - Overall unit heat rate is calculated by dividing total Btu input
by total net generation. Since gross generation is not used, the electrical
auxiliaries used to operate the plant can affect the heat rate significantly.
A. Each unit should have a curve of expected auxiliaries for a given load and it
should be updated whenever equipment is added or removed.
B. An effect on the heat rate due to high plant electrical auxiliaries can be
caused by the following:
1. Operating plant equipment when it is not needed for the plant status.
2. Operate equipment such as service water pumps and air compressors
only as needed.
3. Maintain equipment whose power usage increases with deteriorating
performance such as pulverizers and pumps.
4. Maintain boiler ducts and expansion joints to prevent air inleakage to
conserve FD and ID fan power.
5. Investigate possible installation of variable speed drives for fans instead
of using dampers for air flow control.
6. Outdoor lighting should be controlled by automatic sensors.
7. Maintain heating and air conditioning controls for proper operation.
8. Turn off personal computers when not in use, especially overnight.
3.5 Condenser
A. The condenser receives exhaust steam from the low pressure turbine and
condenses it to liquid for reuse.
B. The water cooled surface condenser is the most common type of condenser
used in modern power plants. Efficiency increases as condenser absolute
pressure decreases. With condenser pressure as low as possible the
amount of heat rejected is lower and the amount of work of the turbine
increases. This is accomplished by optimizing the heat transfer rate between
the condensing steam and the cooling water, effectively allowing no leakage
of air into the condensing space and minimizing any cycle leakage to the
condenser which would add heat load.
C. Things that affect the heat transfer are:

15

11142678
1. Tube fouling or restriction - detected by monitoring absolute back
pressure and the terminal temperature terminal difference between the
turbine exhaust and cooling water outlet temperature. Possible
corrective or preventative measures:
a) Backwashing arrangements may be provided
b) Sponge balls or brushes may be automatically circulated through
the condenser.
c) Periodic condenser tube cleaning
d) Chemical cleaning
e) Install condenser pressure differential transmitters to monitor tube
restrictions
2. Cooling water flow rate inadequate
a) Place additional pumps in service
b) Monitor flow rate
c) Determine if cooling water blowdown is installed on CCW inlet. It
should be installed on the outlet.
d) Test circulating cooling water pumps for proper flow and rebuild as
necessary
e) Maintain clean racks or screens and waterboxes.
3. Cooling water temperature too high
a) Place additional cooling tower cells in service
b) Perform cooling tower maintenance
4. Condenser backpressure too high with proper cooling water
a) Perform helium leak test for condenser inleakage
b) Inspect steam jet air ejectors for proper operation
c) Check incoming drain lines, feedwater heater high level dumps,
minimum flow valves and steam traps for leakage or improper
operation
d) Isolate pressure sensing lines at condenser to check for instrument
line leaks.
3.6 Cooling Towers Condenser cooling water systems are either once through or
closed systems. A once through system is where water is pumped from a river or
lake through the condenser and the warmer water is returned to the source. A
closed loop system rejects the heat to the atmosphere through the use of either
a cooling tower or a body of water such as a cooling lake. Most newer plants use
cooling towers because of the environmental restraints.

16

11142678
A. Cooling tower performance is affected by the ambient wet bulb temperature,
deterioration of the fill material, fill silt buildup, icing on tower structure, low
water loading and high water loading.
B. Wet Bulb temperature - Using the range and the tower outlet temperature,
the corresponding calculated wet bulb temperature can be found from the
vender’s design curves using either the design or measured value for
circulating water flow.
1. If the actual wet bulb temperature is higher than the calculated the tower
is performing at or better that expected.
2. If the actual wet bulb temperature is consistently lower that the
calculated then further testing or inspections are necessary to determine
caused of the deficiency
C. Deterioration of fill material - routine inspections are necessary to survey
damage or deteriorated fill material or to remove any debris
D. Fill silt or algae buildup - Purpose of the fill material is to increase the contact
area between the air and water and to increase the water residence time. To
maintain its maximum effectiveness buildup must be prevented by
blowdown and proper water treatment.
E. Low water loading can cause poor water distribution and high water loading
can cause excessive air pressure losses.
1. Inspect distribution nozzles
2. Clogged distribution nozzles
3. Fan blade deterioration
4. Motor problems
3.7 Feedwater Heaters - Provide three purposes in the power plant.
A. Provide efficiency gains in the steam cycle by increasing the initial water
temperature to the boiler, reducing the amount of heat input required by the
boiler’
B. Provide efficiency by reducing the heat rejected in the condenser.
C. Minimize thermal effects in the boiler.
D. Items that can affect performance:
1. Improper heater level can cause flashing in the drain cooler section and
tube damage
a) Check operation of automatic controls and level instrumentation.
b) Check for possible tube leaks in feedwater heater.
c) Vent valves may not be set up properly.

17

11142678
2. Improper extraction line pressure drops. Possible problem with
extraction line check valve.
3. Tube fouling due to corrosion affects the heat transfer in the heater and
also increases the problem of deposition of oxides on heat transfer
surfaces.
a) Reduce the level of dissolved gases such as oxygen and carbon
dioxide in feedwater and adjust pH of the feedwater.
b) Clean tube bundles
4. Continuous vent orifice plugging
5. Channel pass partition/gasket leak
E. Feedwater Heater Calculations (use Heat Rate Improvement Reference
Manual’ section 3 along with actual plant data to perform calculations)

4. Elements of a Thermal Performance Monitoring Program (the students


should refer to section 4 of the manual throughout this section of study)
4.1 Goals -
A. The goal of a performance monitoring program is to improve unit efficiency.
These are needed because of increased fuel cost, increasing age of the
units and their equipment, increased cost of capitol improvements and
increased competition in the utility industry.
B. Improvements should initially concentrate on activities that can be
accomplished with little capitol investment in a relatively short time.
1. Cycle isolation
2. evaluating selected parameters to improve operations control
3. Identify preventive maintenance that can easily be conducted on select
equipment
4.2 Initial steps for establishing a heat rate monitoring program:
A. Evaluate cycle isolation for leaks or improperly positioned valves (Use
Section 6 of the manual for details on cycle isolation)
B. Determine which performance parameters are being monitored at the unit
with existing instrumentation (use Table 4-1 for a list of parameters that can
be monitored at a typical fossil station).
C. Obtain readings of the selected parameters from Table 4-1 and compare the
readings with expected values. If no historical readings are available use
Table 2-2 as a starting point.
D. Determine the magnitude of the parameters deviation from expected. An aid
in this is to review Table 2-1 for utility experienced deviations.
E. Determine the heat rate deviation as shown in Table 4-4.
18

11142678
F. List the parameters deviating from expected in descending order of effect on
heat rate.
G. Select a parameter to be investigated from the list. Discuss the parameters
and their deviation with unit operators and other plant personnel to ensure
its validity.
H. Review logic trees or parameter diagnostic tables to identify components
effected and potential caused for the deviation. Modify the logic trees from
one of the demonstration reports to suit the unit being evaluated.
I. Refer to performance parameter accounting manual such as found in
Appendix B of the manual, or the Performance Tutorial in section 4. Prepare
a list of possible corrections to the deviation.
J. Review with operations and maintenance to determine the appropriate
action for correction.
4.3 Performance Tutorial - This section of the manual is designed to be of
assistance in identifying losses while operating the plant . Use this section as a
guide to addressing various plant problems that have an effect on plant
efficiency.
4.4 Performance Loss Monitoring and Trending of Key Parameters - This section of
the manual describes how the units performance can be surveyed for losses and
trended to follow the effects of operation .
A. Loss Monitoring - required for determining how well a unit is being
maintained and operated. A successful program consists of:
1. Gathering accurate operating data from adequate sources to provide a
complete status of unit operating parameters.
2. The data must then be incorporated into the proper calculations for
determining actual performance losses for cost/benefit analysis.
3. If a source of degradation is identified the plant staff can then pursue
determining the root cause for the degradation.
4. From the root causes plant staff can optimize their preventive
maintenance program, their instrumentation requirements, operating
practices and their performance parameter monitoring needs.
B. Classification - It is helpful to classify performance losses so responsibilities
for loss reduction can be more effectively delegated
1. Controllable losses - are performance losses that can be minimized by
the plant operating personnel, such as:
a) throttle pressure
b) throttle temperature

19

11142678
c) hot reheat temperature
d) condenser pressure
e) make-up flow
f) feedwater heater terminal temperature difference
g) feedwater heater drain cooler approach temperature
h) main steam desuperheater spray flow
i) reheat desuperheater spray flow
j) auxiliary electrical loads
k) dry gas loss
l) carbon loss
m) coal weighing error
2. Accounted-for losses - those remaining performance losses for which an
effect on heat rate can be determined. These are usually correctable by
maintenance
a) reheater pressure drop
b) extraction line pressure drop
c) hydrogen loss
d) moisture in fuel loss
e) RUMA loss
f) turbine efficiency
g) miscellaneous
h) light-off fuel
3. Unaccounted-for losses - performance losses for which an effect on
heat rate cannot easily be established. These may or may not be known
to exist.
a) heat loss to the condenser
b) soot blowing
c) steam coils usage
d) plant auxiliary steam heating
e) condensate/feedwater recirculation
f) improper valve alignment
g) excessive turbine shaft seal leakages
h) LP turbine efficiency
i) others
20

11142678
C. Quantification - to achieve total benefit from monitoring performance losses,
the effect on unit efficiency must be correctly quantified (use the example in
section 4)
4.5 Unit Performance Survey - not since the initial acceptance tests on many fossil
units has an overall level of performance been established, Since that time unit
operating modes have changed, modifications have been made, coal quality has
changed and equipment has aged. With this in mind it is the primary goal of the
Unit Performance Survey program to determine the present level of overall
performance and to improve it by identifying and minimizing losses. The main
objectives are: (Use section 4 to identify particular items in each of the following
to aide in presenting this section)
A. To stress the importance of performance and to provide a means for ‘on-the-
job’ performance training for station and results personnel.
B. To establish a present level of performance for each fossil unit.
C. To identify cycle and equipment problems and obtain information for use in
problem resolution.
D. To improve the present level of performance of each fossil unit by identifying
and minimizing losses.

5. Instrumentation and Testing Requirements for Heat Rate Monitoring


5.1 Instruments and Performance - A problem with the objective of efficient unit
operation is one which provides the operators with the tools they require to
maintain all important parameters at an optimal value. The operators should also
be motivated to utilize this information to strive for efficient unit operation. The
Thermal Performance program is jeopardized severely when instrument error
exists. This is an unaccounted-for loss undetectable until a calibration is
performed.
A. ASME Performance test codes - if a plant component performance is
suspect, based on on-line testing with normal instrumentation an ASME
Code test can be performed to verify, identify and quantify the problems.
B. Instrumentation - Once it has been decided which performance parameters
should be monitored, and the effect of each of these parameters on unit
heat rate has been determined, the type if instrumentation to be used and
the frequency of monitoring must be decided
5.2 Testing Program - (use section 5 of the manual for a list of periodic and special
testing that may be performed)

6. Cycle Isolation

21

11142678
6.1 Each steam plant has a normal path for the flow of liquid or steam. These can be
different at various loads. These paths are usually well represented on the heat
balance diagrams provided by the vendors. What is not shown are the numerous
paths which are available for liquid or steam to escape from the normal flow
paths.
6.2 When flow is diverted from the normal steam path is either lost from the cycle
completely or returned to a section of the cycle where energy is removed from
the fluid without providing any useful work.
6.3 The only way to appropriately deal with cycle isolation problems is to perform
periodic cycle walkdowns. This will allow a utility to identify the particular losses
that are occurring in a unit and schedule maintenance activities to correct these
problems as required.
6.4 Cycle isolation method
A. Prepare a detailed cycle configuration checklist. This should contain all the
lines not used during normal operation and they should be isolated. This
should also contain all lines which have steam traps to ensure steam trap
operability.
B. The walkdown consists of determining if there is any leakage through the
isolation valve by checking either the downstream pipe wall temperature or
by listening for flow
C. Lines which terminate at the base slab drain or are vented to the
atmosphere can be checked visually.
D. Attention to the deaerator and feedwater vents can be important
E. A list of valves will be produced from the walkdown. This list may need to be
reduced. The reduced list should be used on a frequency bases to check
cycle condition. A number of these valves may need repair.

7. Heat Rate Improvement Program


7.1 The financial success of electric utilities in an increasingly competitive
environment depends largely on improving plant performance to maintain or
lower the cost of producing electricity while meeting ever more stringent
environmental regulations. A heat rate improvement program can include cycle
modifications, component modifications, improved maintenance practices or
increased use of microprocessor based controls and instrumentation.
7.2 Cycle Modifications - examples of cycle modifications include retrofitting a unit
for variable pressure operation, installing variable speed drives on plant
equipment and modification or addition of equipment for improved heat recovery.

22

11142678
A. Variable Pressure Operation - EPRI report GS-6772 presents a discussion
of variable pressure operation for efficiency improvements, a portion of this
report is highlighted in the manual.
B. Variable Speed Drives - an option increasingly being considered in both new
plant designs and life extension projects. Increasing fuel costs and
improvements in technology and reliable have caused a decisive shift
toward the use of this equipment.
1. There are three basic ways a motor’s speed can be changed:
a) change the number of poles on the motor
b) change the slip of the motor
c) change the frequency of the energy supply to the motor
2. Two speed motors - a good example of changing the poses the make a
speed change. These machines do not have the flexibility to meet more
than two plant conditions.
3. Wound rotor motor drives are a form of variable speed drive that has
been found in generating stations throughout the years.
4. The most efficient and most commonly used type of variable speed
equipment is the adjustable frequency synchronous motor. The benefits
are reduced electrical auxiliary usage at reduced loads.
C. Heat Recovery Modifications - a power plant Rankine thermal cycle suffers
tremendous energy losses, therefore it is important to recover even small
heat losses.
1. Circulating water heat recovery - more than half of the fuel burned is lost
to the condenser cooling system. These are considered unavoidable,
but it is possible to recover some of this waste energy for a secondary
use such as air preheating.
2. Air preheating evaluation results are shown in table 7-1, Coil design
operating results in table 7-2
3. Heat pipe air heater technology - are high performance heat transfer
devices that are simple, inexpensive and reliable over a long service life.
There are no moving parts and positive seal connections reduce
leakage to effectively zero while high heat transfer rates permit a low-
weight, low-volume, low-cost package. (use section 7 for a detailed
discussion)
D. Component Modifications - there are many areas in the plant where small
investments can improve unit heat rate and provide cost savings.
1. Boiler duct expansion joint leaks

23

11142678
2. Boiler oxygen measurement is extremely important to proper boiler
operation. The proper number of analyzers and the proper location is
important
3. Windbox damper operation is critical for proper fuel and air mixing.
4. Accurate feedwater heater level controls should be installed and
maintained.
E. Maintenance Practices - if proper unit maintenance is not carefully planned
and executed then unit thermal performance will suffer greatly. A good
performance program should help drive the maintenance plan.
7.3 Cost Benefit Analysis -EPRI report TR-101249 describes the efforts of Southern
California Edison Company to improve heat rate at Ormond Beach Generating
Station Unit 2. A brief of this report is in section 7 of the manual.

8. Appendix A and B
8.1 Appendix A - Procedure for calculating expected unit net heat rate.
A. Purpose - to provide a standard for comparison with actual unit net heat
rate.
B. Use section 8 to guide discussion of net heat rate calculations.
8.2 Appendix B - Performance Parameter Accounting Manual.

24

11142678
POWER PLANT
SYSTEMS

11142678
1. OVERVIEW: This lesson will provide the student with a review of power plant
systems which will include the following:
1.1 The Water/Steam cycle
1.2 Boiler fuel, air and flue gas systems
1.3 Balance of plant systems

2. References:
2.1 Electric Generation Steam Stations, Skrotzki, Bernhardt

11142678
TERMINAL OBJECTIVE

At the end of this lesson the student will understand power plant
systems which will include the following: The Water/Steam cycle, Boiler
fuel, Air and flue gas systems and Balance of plant systems

ENABLING OBJECTIVES

1. Describe the Water/Steam cycle.

2. List the boiler fuels most commonly used.

3. Describe the air and flue gas systems

4. Describe other major plant systems used to produce electrical power.

11142678
LESSON OUTLINE

1. PLANT CYCLES
4.1 1.1 STEAM/WATER CYCLE
4.2 1.2 BASIC CYCLE

5. BOILER FUEL, AIR AND FLUE GAS SYSTEMS


6. BALANCE OF PLANT SYSTEMS

11142678
1. PLANT CYCLES (Water and Steam)
1.1 The steam-water cycle is the heart of the steam-electric power plant. This main
cycle uses two primary types of equipment.
A. Shell and tube type heat exchangers (boilers, superheaters, economizers,
condensers, heaters)
1. Bring two fluids close to each other, one hot and the other cold,
separated by a thin metal wall.
2. The Hot fluid transmits its heat to the cold fluid.
3. Typical problems:
a) Boiler tubes must contain water and steam at very high pressures
while the outer side of the tube can be at very high temperatures
(3500 degrees)
b) Condensers must handle tremendous volumes of exhaust steam
and transmit heat between steam and cooling water whose
temperatures differ by only 20 degrees. Occasionally air leaks by
the sealing mechanisms into the condenser. This air can plate out
on the surfaces of the condenser tubes increasing the heat transfer
medium in which heat must be transferred. The exhaust pressure
will increase and reduce the efficiency of the cycle.
B. Rotating shaft equipment (pumps, fans, turbines)
1. Pumps are used through out the steam-electric plant. Areas where they
are used are:
a) Condensate/Feedwater pumps
b) Chemical addition pumps
c) Fuel oil pumps (oil fired plants)
d) Boiler feed pumps
e) Circulating water pumps
2. Fans are used to provide air to the boiler as:
a) Forced draft fans
b) Induced draft fans
c) Pulverizer fans, primary air fans(Coal fired plants)
3. Turbines are used to provide the rotating motive force for the generator
and for the moving of fluids (turbine driven feedwater pumps)

11142678
1.2 The basic water-steam cycle is the same for all steam-electric power plants.

THE CYCLE:

BOILERS

PUM P TURBINE

CONDENSER

A. Condenser hotwell
1. The condenser hotwell provides a large quantity of boiler quality water to
be circulated through the system to the boiler.
2. This hotwell condensate pumps take a suction on the hotwell and
provide enough discharge pressure to send this water through a number
of condensate heaters
a) The hotwell condensate pumps are usually relatively low pressure
pumps and operates with a low suction head (hotwell is under a
vacuum)
b) These pumps provide suction pressure to a higher head pump.
B. Condensate heaters
1. Condensate heaters provide preheating of the condensate prior to
providing this water to the boiler.

11142678
2. By preheating the water, less energy has to be added to the water in the
boiler to provide the quality of steam required by the turbine/generator
thereby making the cycle more efficient.
3. Heating steam for the condensate heaters is provided to the heaters
from extraction (bleed) steam from different stages of the turbine. The
steam provided to the heaters is compatible (temperature) to provide a
gradual increase in the feedwater temperature.
4. The number of stages of feedwater heating is dependent on the heating
requirements to make the cycle as efficient as is possible. Too few or
too many heaters can make a marked difference in cycle efficiency. The
number of heaters is a function of plant design.
5. Taking heaters out of service will effect cycle efficiency.
C. Condensate/Feedwater is delivered to the boiler at the required pressure by
the boiler feedwater pump. This pump can be a constant speed motor
driven centifugal or variable speed turbine driven centrifugal pump. It can
also be a positive displacement pump.
1. If a constant speed motor driven feedwater pump is used, varying the
amount of feedwater to the boiler must be performed by boiler feedwater
control valves.
2. If a variable speed turbine driven pump is used, a combination of
feedwater pump speed and feedwater control valve position is used to
control boiler water level.
3. This water delivered to the boiler will have energy applied such that the
water will be turned into steam.

W ATER/STEAM CYCLE

Steam
Unheated Downcomer
Heated Riser

11142678
D. Boiler
1. Types of boilers used:
a) Natural draft (circulation) - air is allowed to enter the furnace area of
the boiler to feed the combustion process and the natural flow
through the boiler to the stack is allowed to occur.
b) Forced draft - air is supplied to the furnace area with forced draft
fans and forced though the boiler sections to the stack. This type
boiler produces better heat transfer to all areas of the boiler.
2. Heat left in the combustion gases leaving the boiler is the largest single
loss in a steam generating unit. Economizers are used to recover some
of that heat. The economizer is used to preheat feedwater going to the
lower boiler drum. The hotter the water entering the boiler, the less
energy is required to produce the steam required by the unit.
3. Water that is supplied is heated as it flows up the boiler inside boiler
tubes
4. Heat produced in the boiler through the ignition and burning of fuels
must be transferred through the boiler tube wall to the water flowing
inside. Anything that will reduce the heat transfer of this heat to the
water will reduce cycle efficiency.
5. Steam is produced when the water is heated to the vaporization phase.
6. Superheaters take the saturated steam leaving the steam drum and
raises it’s temperature to the desired level.
7. Steam leaves the boiler through main steam lines to the high pressure
turbine
8. Reheaters provide for greater efficiency of the IP and LP turbines by
increasing the energy of the steam prior to it reaching the IP and LP
turbines. Reheaters also increase the cycle efficiency by using the
combustion gases leaving the furnace.
E. Turbine
1. The turbine is the prime mover of the generator to produce the required
electrical power output.
2. There are numerous arrangements of the high pressure and low
pressure turbines that are used to produce the desired electrical output,
a) single casing, single flow
b) single casing, double flow
c) tandem compound, single or single/double flow
d) tandem compound, triple exhaust

11142678
e) cross compound, double flow
f) cross compound, quadruple exhaust
g) triple cross compound
3. There is usually a single high pressure turbine, possibly an intermediate
pressure turbine and one to three low pressure turbines.
4. The high pressure turbine receives the high pressure steam from the
boiler and produces the highest amount of torque on the turbine shaft. A
large amount of the energy is removed from the steam by this turbine.
5. The steam is then piped to the reheater section of the boiler where
additional temperature and energy is added and then it is directed to the
IP and LP turbine(s). The blades on the IP and LP turbines are much
larger than those on the high pressure turbine. These larger blades
allow the turbine to use more of the steams remaining energy.

THE CYCLE:

BOILER

PUMP TURBINE

CONDENSER

F. Condenser

11142678
1. The steam from the low pressure turbine is exhausted to the condenser
where it is condensed back to a subcooled liquid to begin the
water/steam cycle over again.
2. Circulating cooling water is supplied to the condenser through
condenser tubes to condense the steam. The circulating water can be
supplied from a lake, river, ocean, cooling towers or any other large
supply of cooling water.

2. BOILER FUEL, AIR and FLUE GAS SYSTEMS


2.1 Boilers use various fuels to provide the necessary heat required to produce
steam. These fuels are classified as solid, liquid and gas.
A. Solid fuels are coal (various types of coal are used), wood, coke and even
trash.
1. Coal is ranked by percent moisture, fixed carbon, oxygen and sulfur
content. All of these are determining characteristics which define how
much heat (BTUs) and ash content can be expected to be produced
when burned.
a) The higher the BTU content the less fuel is required to produce the
steam requirements of the plant.
b) The lower the ash and sulfur content the fewer emissions released
from the plant and the less flyash that has to be removed.
c) Flyash plates out on the boiler tubes, especially in the superheat
sections of the boiler. This reduces the heat transfer of the hot
gases to the water/steam and, therefore, reduces cycle efficiency.
d) Sulfur dioxide is a byproduct of the firing process of coal. The higher
the sulfur content the more Sulfer dioxide is produced. This , when
combined with water, produces sulfuric acid.
2. Coke is a byproduct of oil refineries that may be burned in pulverized-
coal-fired boilers.
3. Wood is used usually in the form of waste from lumbering or
manufacturing processes. Special furnaces are required for this fuel.
B. Liquid fuels are oil and coal tars
1. Fuel oils such as diesel fuels to number 6 crude oils are used. Btu
content, water, specific gravity, sulfur and flash point are the test that
oils must undergo prior to use in boilers.
C. Gas used is natural gas
2.2 Air and Flue Gas Systems

10

11142678
A. Inorder for the fuel supplied to the boiler to burn and burn properly air must
be added to the fuel mixture. This is usually provided by forced draft
fans/primary air fans.
1. Forced draft fans are controlled either from the control room.
2. Induced-draft fans are used to “suck” the gases out of the boiler and
deposit them to the stack at a slightly higher than atmospheric pressure.
B. Flue gas temperature leaving the economizer is still quite high. Some of this
energy can be removed and transferred to the inlet air through the use of
air-heaters. Flue gas outlet temperature must be watched closely to ensure
inlet air temperature doesn’t drop too low. If temperature gets too low water
droplets can form in the air. This mixed with the sulfur products produces
sulfuric acid.
C. It has already been stated that when burning fuels byproducts of the fuel
burning process are produced and must be removed from the boiler and the
stack emissions.
1. In the burning of coal slag is produced which falls to the bottom of the
boiler. Systems are provided to crush this slag into particles that are
sized such that they can be sluiced to a holding tank where trucks can
remove them from the plant or sluiced to an area outside of the plant.
2. Flyash is also produced when coal is burned. High efficiency
precipitators have been installed in the flue gas flow path to catch and
funnel flyash to areas where it can be removed from the plant.

3. BALANCE OF PLANT SYSTEMS


3.1 Coal handing equipment or fuel oil handing equipment as well as coal or fuel oil
storage facilities must be provided. There needs to be enough fuel stored to
operate the plant for an extended period of time.
A. Coal must be moved to conveyor belts, then crushed and moved to other
conveyor belts to move it to the top of the plant where it is stored again for
daily use in the plant. This plant storage or ‘hoppers’ must be refilled daily.
The coal is further crushed as necessary to be used in the furnaces in the
boilers.
B. Fuel oil must be stored in large tanks and must be kept at a temperature
such that the oil will flow easily through the piping but not to hot to where is
may ignite prematurely.
3.2 The circulating water system will have some sort of intake screening system to
prevent large objects from entering the condenser waterboxes and possibly
blocking condenser tubes. This will cause a reduction in cycle efficiency.

11

11142678
3.3 Demineralized water must be either produced in the plant or delivered to the
plant by some means. The boilers require clean demineralized water for use in
the boilers. This reduces the amount of deposits and boiler downtime.
3.4 Various oil systems must be provided to lubricate turbine and pump bearings to
prevent component failures. This will also require oil purification systems.

12

11142678
11142678
About EPRI

EPRI creates science and technology


solutions for the global energy and energy
services industry. U.S. electric utilities
established the Electric Power Research
Institute in 1973 as a nonprofit research
consortium for the benefit of utility members,
their customers, and society. Now known
simply as EPRI, the company provides a wide
range of innovative products and services to
more than 1000 energy-related organizations
in 40 countries. EPRI’s multidisciplinary team
of scientists and engineers draws on a
worldwide network of technical and business
expertise to help solve today’s toughest
energy and environmental problems.

EPRI. Powering Progress

© 1999 Electric Power Research Institute (EPRI), Inc. All


rights reserved. Electric Power Research Institute and EPRI
are registered service marks of the Electric Power Research
Institute, Inc. EPRI. POWERING PROGRESS is a service
mark of the Electric Power Research Institute, Inc.

TM-114073

Printed on recycled paper in the United States


of America

EPRI • 3412 Hillview Avenue, Palo Alto, California 94304 • PO Box 10412, Palo Alto, California 94303 • USA
800.313.3774 • 650.855.2121 • askepri@epri.com • www.epri.com

11142678

You might also like