You are on page 1of 2

Used Engine Oil Samples Analysis

Result Result
Test Sample No1 Sample No2
Flash Point by
Pensky-Martens
210 213
Closed Cup Tester
ASTM 93
Flash Point by
Pensky-Martens
224 219
Opened Cup Tester
ASTM 93
Kinematic Viscosity
@ 100˚C 16.95 17.43
ASTM 445
Acid Number
by Potentiometric
6.02 6.43
Titration
ASTM 664
Base Number by
Potentiometric
8.12 7.35
Titration
ASTM 4739
Insolubles in Used
Lubricating Oils 0.28 0.29
ASTM 893 Pentane
Insolubles in Used
Lubricating Oils 0.17 0.2
ASTM 893 Toluene
Water in Petroleum
Products by
Nil traces
Distillation
ASTM 95
Metal Fe 20.2 23.7
content
Ppm Cu 6 4.2
Sample description
Sample No1 No2
Sampling date 3/7/2012 3/7/2012
Site name Shikh zaied Rabwa 2
Applied oil MOBIL DELVAC MX MOBIL DELVAC MX
Running hours 288 288
Total Engine hours 18344 6562