3.5 c FILLING SHOULD BE DONE IN LAYERS NOT EXCEEDING 200mm EACH AND
COMPACTED UPTO 95% DRY DENSITY. THE CONTRACTOR MUST TAKE AT LEAST 2 PLATE
LOAD TESTS TO VERIFY THE SOIL BEARING CAPACITY. FULL TESTING REPORT TO BE
SUBMITED
TO STRUCTURAL ENGINEER FOR STUDY AND APPROVAL.
3.6 ALL ALLOWABLE BEARING PRESSURE OF 200i'#n 2 HAS BEEN ADOPTED FOR THE
DESIGN OF PAD OR STRIP FOOTING. FOOOTING TO BE PLACED AT 14m DEPTH
BELOW FINAL GROUND LEVEL
3.7 AS PER SOIL INVESTIGATION REPORT WATER TABLE WAS ENCOUNTERED STANDING
GROUNDWATER LEVEL OF 1.8 AND 2.0 METERS DEPTH ARE ANTICIPATED AND THEREFORE
EXCAVATIONS AS IN 3.05 a BELOW THESE DEPTHS WILL REQUIRE
DEWATERING. CARE SHOULD BE TAKEN TO PREVENT THE REMOVAL OF FINES DURING
PUMPING SINCE THE COULD RESULT IN LARGELY UNPREDICTABLE SETILEMENT IN THE
SURROUNDING GROUND. (WELL POINT SYSTEM FOR DEWATERING TECHNIQUE)
3.9 ANY GROUND CONDITIONS ENCOUNTERED OR OBSERVED WHICH DIFFER FROM THOSE
EXPECTED SHALL BE REPORTED TO THE SUPERVISING OFFICER IMMEDIATELY.
4.00 CONCRETE :
4.02c ONLY READYMIX CONCRETE SHALL BE USED FOR ALL CONCRETING WORK UNLESS
OTHERWISE APPROVED.
4.02e THE CONCRETE WHICH COMES INTO CONTACT WITH WATER AND CONCRETE COLUMNS
WITH PVC. PIPES ENCASED SHALL CONFORM TO STANDARD OF MINISTRY OF WORKS
SPECIFICATION AND THE FOLLOWING :
THE CONCRETE SHALL CONTAIN AN APPROVED SUPER PLASTICISER AND AN APPROVED
HYDROPHOBIC POREBLOCKING INGREDIENT AT THE RATE OF 30 LITRES PER CUBIC
METRE SUCH THAT THE CONCRETE WILL HAVE A CORRECTED 30 MINUTES WATER
ABSORPTION OF NOT GREATER THAN 1% AS MEASURED BY B.S. 1881 : PART 122 : 1983
EXCEPT THE AGE OF THE TEST SHALL BE 7 DAYS.
4.2 f JOINT GROUT AS PER THE DRAWING AND THE PARTICULAR SPECIFICATION.
4 04 REINFORCED CONRETE BELOW AND INCLUDING GROUND FLOOR SLAB TO BE SRC WITH
A CHARACTERISTIC STRENGTH OF 45 t-ISQ.MM. MIMIMUM CEMENT CONTENT 370 K(iCU.M
AND REINFORCED CONCRETE ABOVE GROUND FLOOR SLAB LEVEL TO HAVE A CHARAC
TERISTIC STRENGTH OF 45 f'ISQ MM AND CEMENT CONTENT 380 K(iCU.M. WITH PFA OR
EOUILVALENT TO MEET WITH ZONE 5 ENVIROMENT SERVICE ZONE MASS CONCRETE TO
HAVE A CHARACTERISTIC STRENGTH NOT LESS THAN 20 t-ISQ MM
4.5 THE CONCRETE FOR COLUMNS FROM GROUND FLOOR SLAB TO FIRST FLOOR SLAB
SHOULD HAVE A CHARACTERISTIC STRENGTH OF 45 f'ISQ.MM WITH ORDINARY PORTLAND
CEMENT. THE UPPER PARTS OF COLUMNS TO HAVE A CHARACTERISTIC STRENGTH OF
45 t-ISQ.MM.
2
4.6 ALL SCREED CONCRETE GRADE TO BE MINIMUM OF 35 N-MM CHARACTERISTIC STRENGTH.
5.00 REINFORCEMENT :
5.01 ALL REINFORCEMENT SHALL BE EITHER HOT ROLLED OR COLD TWISTED DEFORMED
BARS WITH CHARACTERISTIC YIELD STRENGTH Fy = 500 f'ISQ. MM. AND CONFORM
TO B.S. 4449 OR B.S. 4461, ASTM 615