TROUBLESHOOTING FOR CONTROL CIRCUITS

Problem: Pump Motor, Faulty Transistor Drive (33)


Indication: "33" display. Vehicle operation (traction and pump motors) disabled.

(1) Situation
Indication: "33" display. Vehicle operation disabled.

(2) Possible cause


Wire break in T1P, faulty drive board, faulty CS3 current sensor, faulty logic card, faulty wiring.

(3) How the error code is triggered


Software checks following signal and detects fault when line contactor closes.
Pump Error (CN2-32)

(4) Checks
Disconnect battery plug. Check T1P for abnormality. See page 3-54.
Acceptable Unacceptable

(5)Check drive board. Check wiring between drive board (12) Replace faulty component (T1P).
and logic card, and between drive board and T1P for
abnormality. See pages 3-52 to 3-56.
Acceptable Unacceptable

(6) Check CS3 current sensor for abnormality. Check (11) Replace drive board or wiring.
wiring between CS3 and logic card for abnormality.
See page 3-49.
Acceptable Unacceptable

(7) Check logic card, connector and wiring for abnormality. (10) Replace CS3 current sensor or wiring.
See pages 3-37 to 3-42.
Wiring acceptable Wiring unacceptable

(8)Replace logic card. (9) Clean connector or


correct wiring, or replace
logic card or wiring.