A YASKAWA AC Drive

High Performance Vector Control


A1000 HHP

RoHS
400 V Class 300 HP to 1800 HP compliant
600/690 V Class 400 HP to 2250 HP
*CE and UL approval still pending for some models
Yaskawa Electric Corporation
Marketing Section
Drives Division
A Summary of Features for A1000 HHP
The Concept of A1000 HHP

• Based on COSMOS Technology (9th generation).


• Drive system will be all new control and power modules.
• 460 & 690 V (G5HHP was 460 & 600V).
• Architecture of A1000 HHP is similar to G5HHP DC5HHP.
• Able to parallel 5 modules instead of 4 modules (G5HHP-DC5HHP).
• Modules are NEMA type 12 and NEMA 3R capable heatsinks.
• Software functionality, parameters, keypad interface, etc will be the same the
chassis version.
• Input and output voltage feedback is added.
• Variable Speed 24 VDC cooling fans for better cooling control
• Output reactors will be smaller (1% for G5 HHP, ½% for A1000)
A A1000 HHP Topology

Even More Compact


A1000 400V 1000kW (AC Input Power)
R/L1 CONV 1POWER MODULE
S/L2
T/L3 24 VDC
Power supply

MC

Main IGBT Voltage


Fuse Gate Drive feed back
Output Voltage feed back
R1/L11
S1/L21 24 VDC
U/T1
T1/L31 24 VDC V/T2
2 POWER MODULE Power supply W/T3

24 VDC
Thermistor
3 POWER MODULE Power supply

24 VDC
4 POWER MODULE
Power supply

24 VDC
5 POWER MODULE
Power supply

24 VDC
r/l1 Power supply New
+ to control circuit Control
s200/l2200
Gate drive circuit A/D
s400/l2400
24VDC Power 24 VDC
s690/l2690 supply to FAN
and MC A1000
To Gate Drive Operator
To FAN and MC Control Terminal

I/O

3/30
A A1000HHP panel

1 3
Power Power module Output AC reactor Motor
supply
Rectifier
Power module Output AC reactor
module

4
Power module Output AC reactor

2 5 6
DC link Control module Power supply
reactor module

Control Power Supply


7 Transformer

4/30
A Filter panel for D1000HHP D1000HHP panel A1000HHP panel

11 12 8 9 3 or 9
Power
Filter Input AC Pre-charge module Power module Power module Output AC Motor
supply
reactor reactor

Input AC Pre-charge module Power module Power module Output AC


reactor reactor

4
Input AC Pre-charge module Power module Power module Output AC
reactor reactor

10 6 5 6
Power supply Power supply
Control module Control module
module module

Control Power Supply Control Power


7 Transformer 7 Supply 9
Transformer

5/30
A
More Compact
■ New Module Design has a reduced footprint
New A1000 HHP module is more compact allowing for reduced panel size.

■Inverter Module ■ Small Converter Module ■ Large Converter Module


G5HHP G5HHP
G5HHP
G5HHP Conv Conv
Inv Mod
Conv Mod Mod
Mod 600 kW 600 kW
600 kW

214
mm

1044 A1000 1144 1094 A1000 HHP


1194 mm 1194
mm HHP Inv mm Conv Mod
mm mm
Mod 1500 kW

A1000 HHP
Conv Mod 794
900 kW mm

248 mm
286 mm
286 mm
286 mm
458 mm
A
More Compact
■ New Module Designs are more compact than G5HHP

■ 300 kW* Inverter ■ 900 kW* Converter ■ 1500 kW* Converter

*Power @ 600/690V.
A
New Improved Cooling
■ New Module Design has new heatsink design that is capable of NEMA 12 or NEMA 3R

8/30
A

9/30
A
New Improved Cooling for NEMA type 12/3R

Mounting ring to seal


between external heatsink,
and internal components
A

11/30
A
A

13/30
A

14/30
15
AMotor
Capacity
(Hp)

300
Product Lineup
Normal Duty
Model
CIMR-AU4H0466
Three-Phase 400V

Rated Output
466 A
Heavy Duty
Model
CIMR-AU4H0466
Rated Output
414 A
Normal Duty
Model
CIMR-AU4H0466
Three-Phase 600/690V

Rated Output
466 A
Heavy Duty
Model
CIMR-AU4H0466
Rated Output
414 A
400 CIMR-AU4H0466 466 A CIMR-AU4H0900 800A CIMR-AU4H0466 466 A CIMR-AU4H0466 414 A
500 CIMR-AU4H0900 900 A CIMR-AU4H0900 800 A CIMR-AU4H0900 900 A CIMR-AU4H0900 414 A
600 CIMR-AU4H0900 900 A CIMR-AU4H0900 800 A CIMR-AU4H0900 900 A CIMR-AU4H0900 800 A
700 CIMR-AU4H0900 900 A CIMR-AU4H0900 800 A CIMR-AU4H0900 900 A CIMR-AU4H0900 800 A
800 CIMR-AU4H0900 900 A CIMR-AU4H1350 1200 A CIMR-AU4H0900 900 A CIMR-AU4H0900 800 A
900 CIMR-AU4H1350 1350 A CIMR-AU4H1350 1200 A CIMR-AU4H0900 900 A CIMR-AU4H1350 1200 A
1000 CIMR-AU4H1350 1350 A CIMR-AU4H1350 1200 A CIMR-AU4H1350 1350 A CIMR-AU4H1350 1200 A
1200 CIMR-AU4H1800 1800 A CIMR-AU4H1800 1600 A CIMR-AU4H1350 1350 A CIMR-AU4H1350 1200 A
1400 CIMR-AU4H1800 1800 A CIMR-AU4H2250 2000 A CIMR-AU4H1350 1350 A CIMR-AU4H1800 1600 A
1500 CIMR-AU4H1800 1800 A CIMR-AU4H2250 2000 A CIMR-AU4H1800 1800 A CIMR-AU4H1800 1600 A
1600 CIMR-AU4H2250 2250 A CIMR-AUH42250 2000 A CIMR-AU4H1800 1800 A CIMR-AU4H1800 1600 A
1750 CIMR-AU4H2250 2250 A CIMR-AU4H1800 1800 A CIMR-AU4H2250 2000 A
1800 CIMR-AU4H2250 2250 A CIMR-AU4H1800 1800 A CIMR-AU4H2250 2000 A
2000 CIMR-AU4H2250 2250 A CIMR-AU4H2250 2000 A
2250 CIMR-AU4H2250 2250 A
A A1000 HHP Ratings

1P 2P 3P 4P 5P
Output ND 466 900 1350 1800 2250
Amps HD 414 800 1200 1600 2000

400 V 460 V ND 371 717 1075 1433 1792


Module output kVA HD 330 638 955 1274 1592

600 V ND 483 934 1402 1870 2337


600/690V output kVA HD 430 831 1246 1662 2077
Module 690 V ND 557 1076 1613 2151 2689
output kVA HD 495 956 1434 1912 2390
A A1000 HHP Unparalleled Performance

600V, 300 kW
Inverter
18/30
A

1500 kW Converter
(with DC Bus Choke)
19/30
A

1500 kW Converter
12 Pulse
(with DC Bus Choke)
20/30
A

Control Module (front) 21/30


A

Control Module (rear)


22/30
A

1400 HP Dyne
23/30
A

dV/dT filter (450A)

24/30
A Cell Reactor
regen (466A)

25/30
A

AC Line Reactor
Regen(900A)

26/30
A Lifting Applications

ESP – Electric Submersible Pump


P1000 and HHP Applications
with special YEA software
Very large HP and often step-
up/step-down transformers and
sine wave output filter
100 to 2000 HP – VT only
Depending on customer –
occasionally requires 12 or 18
pulse front end
A Drilling Applications

TOP DRIVES –
Large HP 800 – 1200 HP
Rotating the drill string

Draw Works –
Large HP 400 – 800 HP
Winching the Top Drive
29
30
31
32