You are on page 1of 11

PL-01/2020 PRICE LIST 15-05-2020

MINIATURE CIRCUIT BREAKERS

Miniature circuit breakers (ACTI 9) are available in different breaking capacities (6 to 35kA), current rating from 1 to 100
Amps. Available in B,C and D tripping curves. These breakers comply with IEC 947-2 and IEC 898 standards. These MCB's
are also suitable for DC application up to certain voltages. (Please consult us for application).
PL-2020
Type Ratings Icu Icu Unit Rate
SINGLE POLE IEC 898 IEC 947-2 (Rs.)
DOMAE 6,10, Amps 6 kA - 480
DOMAE 16,20,25,32, Amps 6 kA - 400
DOMAE 40 Amps 6 kA - 460
iC60N 1, 3, 4 Amps 6 kA 10 kA 2,000
iC60N 2 Amps 6 kA 10 kA 1,600
iC60N 6,10, 50, 63 Amps 6 kA 10 kA 800
iC60N 16,20,25,32 ,40 Amps 6 kA 10 kA 650
C120N 80, 100 Amp 6 kA 10 kA 4,000

DOUBLE POLE
DOMAE 6,10, Amps 6 kA - 1,660
DOMAE 16,20,25,32 Amps 6 kA - 1,400
DOMAE 40 Amps 6 kA - 1,500
iC60N 2,4 Amps 6 kA 10 kA 6,000
iC60N 6,10 Amps 6 kA 10 kA 2,700
iC60N 16,20,25,32 ,40 Amps 6 kA 10 kA 2,200
iC60N 50,63 Amps 6 kA 10 kA 2,700

C60H-DC / C32H-DC
C32H-DC 2, 4 Amps
Amps - 20 kA 7,500
7,500
C60H-DC / C32H-DC 6,10, Amps - 20 kA 6,500
C60H-DC / C32H-DC 16,20,25,32, Amps - 20 kA 5,800
C60H-DC / C32H-DC 40,50,63 Amps - 20 kA 7,000

TRIPLE POLE
DOMAE 6,10 Amps 6 kA - 2,700
DOMAE 16,20,25,32,40 Amps 6 kA - 2,200
DOMAE 40 Amps 6 kA - 2,300
iC60N 2,4 Amps 6 kA 10 kA 8,000
iC60N 6,10 Amps 6 kA 10 kA 4,000
iC60N 16,20,25,32 Amps 6 kA 10 kA 3,200
iC60N 40, 50,63 Amps 6 kA 10 kA 3,800

IC60H / C60H 6,10 Amps 6 kA 15kA 5,600


IC60H / C60H 16,20,25,32,40 Amps 6 kA 15kA 4,800
IC60H / C60H 50,63 Amps 6 kA 15kA 5,600

C120N 80,100 Amps - 10 kA 9,200


FOUR POLE
iC60N 6,10 Amps 6 kA 10 kA 5,700
iC60N 16,20,25,32 ,40 Amps 6 kA 10 kA 4,600
iC60N 50,63 Amps 6 kA 10 kA 5,500
C120N 80,100 Amps - 10 kA 13,000
OTHER EQUIPMENT
iSD For iC60N ALARM SWITCH iSD A9A26927 2,100
iOF For iC60N AUX. SWITCH iOF A9A26924 1,200
iOF + iSD / iOF For iC60N Aux. SWITCH iOF + iSD or iOF A9A26929 2,700
iMN For iC60N U.V.T 220 VAC A9A26960 4,500
iMX For iC60N SHUNT TRIP 220 VAC A9A26476 4,200
SD For C60H-DC / C120N ALARM SWITCH SD A9N26927 3,000
OF For C60H-DC/C120N AUX. SWITCH OF A9N26924 1,500
LOCKING DEVICE For MCB iC60N A9A26970 400
DISCOUNT APPLICABLE, SUBJECT TO PAYMENT TERMS AND ORDER VALUE.
All items are stocked in reasonable quantities, subject to prior sale.

INCLUSIVE
PRICES ARE INCLUS IVE OF GST
AZCORP
PRICE LIST OF AZCOR P ENGINEERING SERVICES Page 1 of 6
DISTRIBUTOR SINCE 11985
985
PL-01/2020 PRICE LIST 15-05-2020

PL-2020
UNIT RATE
LIGHT/AUTOMATION CONTROL PRODUCTS
(Rs.)
Twilight Switches
IC2000 IC 2000 Twilight Switch 2- 2000 CCT15369 ( New Model ) 11,000

Time Switch Mechanical


18 mm widht IHP 24h 1c ARM 15336 9,000
54 mm widht IH 24h + 7d 2c ARM 15366 12,000
54 mm widht IH 24h 1c ARM CCT15365 10,000
45 mm widht IHP 7d 1c CCT15851 11,000
IMPULSE RELAY
iTL IMPULSE RELAY 16A 1P 230VAC/110VDC A9C30811 1,900
TL IMPULSE RELAY 32A 1P 230VAC/110VDC 15515 / A9C30831 3,000
TL IMPULSE RELAY 16A 2P 230VAC/110VDC 15520 2,600
ETL EXTENSION RELAY 32A 1P 230VAC/110VDC 15505 1,100
PROTECTION DEVICES - Surge Arrestor
iPF40 DP Fixed Type 40 KA - A9L400200 8,800
iPF40 FP Fixed Type 40 KA - A9L15688 14,500

EARTH LEAKAGE CIRCUIT BREAKERS


RCCB D.P 25, 40 Amps ( 30mA, 300mA sensitivity) 4,000
RCCB D.P 63 Amps ( 30 mA sensitivity) 4,900
RCCB D.P 63 Amps ( 300 mA sensitivity) 5,500
RCCB F.P 40 Amps ( 30mA, 300mA sensitivity) 5,400
RCCB F.P 63 Amps ( 30mA sensitivity) 7,300
RCCB F.P 63 Amps ( 300 mA sensitivity) 6,000
RCCB F.P 100 Amps ( 30mA sensitivity) 13,000
RCCB F.P 100 Amps ( 300mA sensitivity) 11,500
IC60H RCBO, Residual Current Circuit Breaker With Overload Protection:
RCBO 1P + N 6 Amps ( 30mA, sensitivity) A9D14806 4,400
RCBO 1P + N 10 Amps ( 30mA, sensitivity) A9D14810 4,400
RCBO 1P + N 16 Amps ( 30mA, sensitivity) A9D14816 4,400
RCBO 1P + N 20 Amps ( 30mA, sensitivity) A9D14820 4,400
RCBO 1P + N 25 / 32 Amps ( 30mA, sensitivity) A9D14825/32 4,800
EARTH FAULT RELAYS:
RH99M Sensitivity : 0.3 - 30 A (Adj) , 0 - 4.5 S Adj. 56173 27,000
TOROID dia 50mm 50438 7,400
TOROID dia 80mm 50439 12,500
TOROID dia 120mm 50440 19,000
TOROID dia 200mm 50434 34,000
Please add to the cost of breaker one Shunt trip to complete the scheme.
POWER FACTOR CONTROLLER "VARLOGIC"
NR 6 / VPL 06N 6 Stages 60,000
NR 12 / VPL 12N 12 Stages 73,000
STANDARD DUTY CAPACITORS " CAN TYPE "
12.5 / 13.5 KVAR, 400/415VAC BLRCS125A150B40 13,000
25 / 26.9 KVAR, 400/415VAC BLRCS250A300B40 15,300

HEAVY DUTY CAPACITORS " CAN TYPE "


12.5 KVAR 440V BLRCH125A150B44 18,000
25.4 / 28.5 KVAR 415/440V BLRCH285A342B44 32,000
50.8 / 57.1 KVAR 415/440V BLRCH571A000B44 56,000

PRICES
PRICES ARE INCLUSIVE OF GST
PRICE
PRICE LIST OF AZCORP ENGINEERING SERVICES
DISTRIBUTOR SINCE 1985 Page
Page 2 of 6
PL-01/2020 PRICE LIST 15-05-2020

MOULDED CASE CIRCUIT BREAKDRES : 3 POLE PL-2020

Adjustable Trip: 70 - 100% x In IEC 947-2


Unit Rate (Rs.)
NSX100F TM-D 16, 25, 32, 40,50, 63 Amps. 36 kA 100% 11,200
NSX100F TM-D 80, 100 Amps. 36 kA 100% 11,500
NSX160F TM-D 125 Amps. 36 kA 100% 17,000
NSX160F TM-D 160 Amps. 36 kA 100% 21,000
NSX250F TM-D 200, 250 Amps. 36 kA 100% 32,000
NSX100H TM-D 16, 25, 32, 40,50, 63 Amps. 70 kA 100% 18,000
NSX100H TM-D 80, 100 Amps. 70 kA 100% 18,000
NSX160H TM-D 125 Amps. 70 kA 100% 23,000
NSX160H TM-D 160 Amps. 70 kA 100% 26,000
NSX250H TM-D 200, 250 Amps. 70 kA 100% 38,000
Adjustable Electronic Trip : 40 - 100% x In ( Micrologic 2.3 )
NSX400N Ir= 160 ~ 400A Im= 2~10 x In 50 kA 100% 57,000
NSX630N Ir= 250 ~ 630A Im= 2~10 x In 50 kA 100% 72,000
NSX400H Ir= 160 ~ 400A Im= 2~10 x In 70 kA 100% 66,000
NSX630H Ir= 250 ~ 630A Im= 2~10 x In 70 kA 100% 85,000
TRIP UNIT : MICROLOGIC 2.0 Long Time Trip Setting Ir :
Instantenous Stteing Im : 1.5 - 10 Times Thermal Memory :
NS800N Micrologic 2.0 800 Amps. 50 kA 100% 130,000
NS1000N Micrologic 2.0 1000 Amps. 50 kA 100% 148,000
NS1250N Micrologic 2.0 1250 Amps. 50 kA 100% 160,000
NS1600N Micrologic 2.0 1600 Amps. 50 kA 75% 190,000
NS800H Micrologic 2.0 800 Amps. 70 kA 75% 140,000
NS10 00H Mic
NS1000H rologic 2.0
Micrologic 1000 Amps. 70 kA
kA 75% 170,000
170,000
NS1250H Micrologic 2.0 1250 Amps. 70 kA 75% 180,000
NS1600H Micrologic 2.0 1600 Amps. 70 kA 75% 210,000

MOULDED CASE CIRCUIT BREAKDRES : 4POLE IEC 947-2


NSX100F 40, 63, 100 Amps. 36 kA 100% 20,000
NSX160F 160 Amps 36 kA 100% 30,000
NSX250F 250 Amps 36 kA 100% 50,000
Electronic Trip Unit Micrologic 2.3
NSX400N 400 AMPS / Adjustable 160 ~ 400A 50 kA 100% 84,000
NSX630N 630 AMPS / Adjustable 250 ~ 630A 50 kA 100% 110,000
NS800N Micrologic 2.0 800 Amps. 50 kA 100% 200,000
NS1000N Micrologic 2.0 1000 Amps. 50 kA 100% 220,000
NS1250N Micrologic 2.0 1250 Amps. 50 kA 100% 225,000

Optional Accessories: NSX100 / 250N NSX400 / 630 NS800 / 2000


AUX. SWITCH "OF" or "SD" 1C/O 3,500 3,500 3,500
SHUNT TRIP MX 220VAC 7,500 7,500 15,500
UVT TRIP MN 220VAC 11,000 11,000 15,500
DIRECT ROTARY HANDLE 9,500 8,800 12,500
EXT. ROTARY HANDLE + D I/L 9,500 13,000 25,000
MOTOR MECHANISM 220VAC "T" 42000 / 55000 100,000 N/A
LOCKING DEVICE (TOGGLE) 1,800 1,800 1,800
Other Voltages : + 10%

PRICES
PRICES ARE INCLUSIVE OF GST
PRICE LIST OF AZCORP ENGINEERING SERVICES
PRICE
DISTRIBUTOR SINCE 1985
DISTRIBUTOR Page 3 of 6
PL-01/2020 PRICE LIST 15-05-2020

EasyPact , CVS Range


The EasyPact CVS range of class II, MCCB is precision engineered to help make your installation safer and more reliable while adapting
to today's tight construction and upgrade budgets. Offering exceptional capability, quality, and value, EasyPact CVS is the easy choice
for all most common electrical distribution application in medium-size commercial and industrial buildings.
MCCB Adj. Thermal Magnetic Trip - TMD : 3 POLE IEC 947-2 PL-2020
Type Ratings Icu Ics Unit Rate
= % of Icu (Rs.)
CVS100B 25, 32, 40,50, 63 Amps. 25 kA 100% 9,000
CVS100B 80, 100 Amps. 25 kA 100% 9,300
CVS160B 125 Amps 25 kA 100% 13,000
CVS160B 160 Amps 25 kA 100% 16,000
CVS250B 200, 250 Amps 25 kA 100% 24,000
CVS100F 25, 32, 40,50, 63 Amps. 36 kA 100% 9,300
CVS100F 80, 100 Amps. 36 kA 100% 9,800
CVS160F 125 Amps 25 kA 100% 15,000
CVS160F 160 Amps 36 kA 100% 18,000
CVS250F 250 Amps 36 kA 100% 28,000
CVS400F 400 Amps / Adjustable 280 ~ 400A 36 kA 100% 43,000
CVS630F 600 Amps / Adjustable 420 ~ 600A 36 kA 100% 56,000
MCCB Adj. Thermal Magnetic Trip - TMD : 4 POLE IEC 947-2
CVS100B 40, 63 Amps. 25 kA 100% 15,000
CVS100B 80, 100 Amps. 25 kA 100% 16,000
CVS160B 160 Amps 25 kA 100% 24,000
CVS250B 200 Amps 25 kA 100% 35,000
CVS250B 250 Amps 25 kA 100% 35,000
CVS400F 400 Amps / Adjustable 280 ~ 400A 36 kA 100% 52,000
CVS630F 600 Amps / Adjustable 420 ~ 600A 36 kA 100% 72,000
MCCB FIXED Thermal Trip : 3 POLE IEC 947-2
Economical Series Ics Unit Rate
Type Ratings Icu = % of Icu (Rs.)
Easy Pact is new generation of MCCB. Is smallest in its range with one frame size for all rating & breaking capacities to suit
all types of applications tested as per IEC 60947-2 specifications.
EZC100F 15,20,30,40,50,60,80,100 Amps 10 kA 50% 5,300
EZC100N 15,20,30,40,50,60,80,100 Amps 15 kA 50% 5,700
EZC100H 15,20,30,40,50,60,80,100 Amps 30 kA 50% 7,800
EZC250F 125, 150 Amps. 18 kA 50% 12,800
EZC250F 200, Amps. 18 kA 50% 13,500
EZC250F 250, Amps. 18 kA 50% 14,000
EZC250N 125, 150 Amps. 25 kA 50% 14,000
EZC250N 200, 250 Amps. 25 kA 50% 17,000
EZC250H 125, 150 Amps. 36 kA 50% 16,000
EZC250H 200 Amps. 36 kA 50% 22,000
EZC250H 250 Amps. 36 kA 50% 22,000
EZC400N 300, 400 Amps. 36 kA 50% 36,000

PRICES ARE INCLUSIVE OF GST


PRICE LIST OF AZCORP ENGINEERING SERVICES
DISTRIBUTOR SINCE 1985 Page 4 of 6
PL-01/2020 PRICE LIST 15-05-2020

AIR CIRCUIT BREAKERS * MASTERPACT *


These LOW VOLTAGE ACB MASTERPACT offer the
Switch board builders and circuit designers a range of modern units
certified for use on 3 phase 4 wire systems, for current rating up to 6300 Amps.
- MASTERPACT AIR CIRCUIT BREAKERS 3P & 4P 690 VAC,Non Withdrawable
- INTERRUPTION CAPACITY AS PER IEC 947-2, BS4752
- (R.M.S SENSING + SELECTIVE) MICROLOGIC 2.0E & 5.0E
- FAULT INDICATION CONTACT "SD"
- No. OF AUX CONTACT 4 C/O
- OVER RUN LED INDICATOR 3P
Type Rating Thermal Trip Icu=Ics=Icw Unit Rate Rs
NW08H1, 2.0E 800 Amps 320 to 800A 65 KA 300,000
NW10H1, 2.0E 1000 Amps 400 to 1000A 65 KA 305,000
NW12H1, 2.0E 1250 Amps 500 to 1250A 65 KA 310,000
NW16H1, 5.0E 1600 Amps 630 to 1600A 65 KA 350,000
NW20H1, 5.0E 2000 Amps 800 to 2000A 65 KA 395,000
NW25H1, 5.0E 2500 Amps 1000 to 2500A 65 KA 500,000
NW32H1, 5.0E 3200 Amps 1250 to 3200A 65 KA 640,000
NW40H1, 5.0E 4000 Amps 1600 to 4000A 65 KA 880,000
uest NW50 & NW63
HIGH BREAKING CAPACITY
NW08H2, 2.0E 800 Amps 320 to 800A 100 KA 340,000
NW10H2, 2.0E 1000 Amps 400 to 1000A 100 KA 355,000
NW12H2, 2.0E 1250 Amps 500 to 1250A 100 KA 370,000
NW16H2, 5.0E
5.0E 1600 Amps 630 to 1600A 100 KA
KA 390,000
390,000
NW20H2, 5.0E 2000 Amps 800 to 2000A 100 KA 480,000
NW25H2, 5.0E 2500 Amps 1000 to 2500A 100 KA 590,000
NW32H2, 5.0E 3200 Amps 1250 to 3200A 100 KA 740,000
NW40H2, 5.0E 4000 Amps 1600 to 4000A 100 KA 1,000,000
uest NW50 & NW63
DRAWOUT CHASIS 3 POLE, FOR NW ACB:
800A to 1600A 112,000
2000A 120,000
2500A 125,000
3200A 180,000
4000A 200,000
OPTIONAL ACCESSORIES:
- Under voltage trip 220 VAC MN 15500
- Time delayed under Unit 220VAC MNR 35000
- Shunt trip / Closing Coil 220 VAC MX, XF 15500
- Key lock Assembly ( 48539 + 41940+ 48564 ) RONIS 12500
- Push Button Locking Cover Padlock 6000
- Motor charged spring operation mechanism 220VAC MCH 90000
- Mechanical Interlock flexible VM2FC 90000
- Mechanical Interlock rigid VM2FT 90000
- Additional 4 C/O Contact 4 OF 14000
- Neutral CT For E/F Protection Up to 2000A 105000
- Neutral CT For E/F Protection 2000 to 4000A 118000

Other Voltages : + 10 % ( 24VDC, 110VAC)

PRICES
PR ICES ARE IINCLUSIVE
NCLUSIVE OF GST
OF
PRICE LIST O SERVICES
F AZCORP ENGINEERING SERVICE S
1985
DISTRIBUTOR SINCE 1985 Page 5 of 6
PL-01/2020 PRICE LIST 15-05-2020

DIGITAL METERS

The Power Logic DM6000,DM3000 & PM1000 series digital panel meters offer the basic measurement
capabilities required to monitor an electrical installation. The power Logic PM5100 series power meters are
ideal fit for cost management applications. It provides the measurement capabilities needed to allocate
energy savings, optimize equipment efficiency and utilization, and perform a high level assessment of the
power quality of the electrical network.
PL-2020
Type Characteristics
(Rs.)
DM1110 1 Phase Digital Ammeter ( 96 x 96 mm ) LED, 5A 3,200
DM1210 1 Phase Digital Voltmeter ( 96 x 96 mm ) LED, 480V 3,100
DM1310 1 Phase Digital Frequency ( 96 x 96 mm ) LED, 5A 3,500
DM3110 3 Phase Digital Ammeter ( 96 x 96 ) Bright LED Indicator 100~230V 4,500
DM3210 3 Phase Digital Voltmeter ( 96 x 96 ) Bright LED Indicator 100~230V 3,600

PM9 Digital Multimeter, ( 72 x 90 ) LCD Display, Volt, Current, Power, Power 5,000
Factor, Active & Reactive Energy, Frequency, 220V.

DM6000 Digital Multimeter, ( 96x 96 ) Bright LED indicator, RPM, Phase angle, Phase 14,000
unbalance, Power Factor, Frequency, Voltage and current. 44~277 V AC/DC
Digital Multimeter, ( 96x 96 ) Bright LED indicator, RPM, Phase angle, Phase
DM6200 unbalance, Power Factor, Frequency, Voltage and current. Modbus ( RS485 15,000
) 44~277 V AC/DC.

PM2110 Power Meter (+MDI), ( 96x 96 ) LED Digital, Power Factor, Active & Reactive 26,000
Energy, Active & Reactive Power, Frequency, current. 44~277 V AC/DC.
Power Meter (+MDI), ( 96x 96 ) LED Digital, Power Factor, Active & Reactive
PM2120 Energy, Active & Reactive Power, Frequency, current. Modbus ( RS485 ) 31,000
44~277 V AC/DC.

EM6436D / Dual Source Energy Meter, ( 96x 96 ) Modbus ( RS485 ) 44~300 V AC/DC. 24,000
PM1130HCL05RS
Power Meter , ( 96x 96 ) LCD Display, Active Power, Total, Per Phase,
PM710/5110 Apparent Power, Total, Per Phase, Power Factor, Current, Frequency, 68,000
Reactive Power Total, Per Phase, Energy Active, Reactive Apparent.
Power Meter , ( 96x 96 ) LCD Display, Active Power, Total, Per Phase,
PM750/5310 Apparent Power, Total, Per Phase, Power Factor, Current, Frequency, 70,000
Reactive Power Total, Per Phase, Energy Active, Reactive Apparent.

PRICES ARE INCLUSIVE OF GST


PRICE LIST OF AZCORP ENGINEERING SERVICES
DISTRIBUTOR SINCE 1985 Page 6 of 6
PL-01/2020 PRICE LIST 15-05-2020

AIR BREAK MAGNETIC CONTACTORS, 3 POLE: ( 220VAC Coil )


MAGNETIC CONTACTOR CURRENT RATING AC1 AND AC3: TeSys
CURRENT RATING AND MOTOR kW (HP) UNIT RATE
AUXILIARY OPERATING CYCLES UPTO 440V AT 415V (Rs.)
NEW TYPE
CONTACTS AC 1 up to 55oC AC 3 up to 55oC AC 3; < 55oC PL : 2020
AMPS AMPS
LC1-D09 1N/O+1N/C 25A 9A 4 ( 5.5 ) 1,720
LC1-D12 1N/O+1N/C 25A 12A 5.5 ( 7.5 ) 2,100
LC1-D18 1N/O+1N/C 32A 18A 7.5 ( 12 ) 2,900
LC1-D25 1N/O+1N/C 40A 25A 11 ( 15 ) 4,050
LC1-D32 1N/O+1N/C 50A 32A 15 ( 20 ) 5,700
LC1-D40A 1N/O+1N/C 60A 40A 18.5 ( 30 ) 8,200
LC1-D50A 1N/O+1N/C 80A 50A 22 ( 33 ) 9,200
LC1-D65A 1N/O+1N/C 80A 65A 30 ( 50 ) 12,000
LC1-D80 1N/O+1N/C 125A 80A 37 ( 60 ) 15,500
LC1-D95 1N/O+1N/C 125A 95A 45 ( 60 ) 18,000
LC1-D115 1N/O+1N/C 200A 115A 55 ( 77 ) 24,000
LC1-D150 1N/O+1N/C 250A 150A 75 ( 105) 28,000
LC1-F115 NOT INCLUDED 200A 115A 59 ( 77 ) 37,000
LC1-F150 NOT INCLUDED 250A 150A 80 ( 105 ) 43,500
LC1-F185 NOT INCLUDED 275A 185A 100 ( 134 ) 50,000
LC1-F225 NOT INCLUDED 315A * 225A 110 ( 147 ) 60,000
LC1-F265 NOT INCLUDED 350A * 265A 140 ( 175 ) 68,000
LC1-F330
LC1 -F330 NOT
NOT INCLUDED 400A * 330A
330A 180 ( 210 ) 85,000
85,000
LC1-F400 NOT INCLUDED 500A * 400A 220 ( 265 ) 100,000
LC1-F500 NOT INCLUDED 700A * 500A 280 ( 330 ) 122,000
LC1-F630 NOT INCLUDED 1,000A * 630A 375 ( 445 ) 190,000
LC1-F800 NOT INCLUDED 1,000A * 800A 450 ( 600 ) 500,000
CONTROL RELAYS 220VAC Coil.
CAD-32 3 N/O + 2 N/C 2,500
CAD-50 5 N/O 2,600
CONTROL RELAYS 24 VDC Coil.
CAD-32 3 N/O + 2 N/C 5,200
CAD-50 5 N/O 6,000

AIR BREAK MAGNETIC CONTACTORS, 3 POLE: ( 24V DC COIL )


LC1-D12BD 1N/O+1N/C 25A 12A 5.5 ( 7.5 ) 4,300
LC1-D18BD / BL 1N/O+1N/C 32A 18A 7.5 ( 12 ) 5,600
LC1-D25BD / BL 1N/O+1N/C 40A 25A 11 ( 15 ) 8,000
LC1-D32BD / BL 1N/O+1N/C 50A 32A 15 ( 20 ) 10,500

AUX. CONTACT BLOCK FOR MOUNTING ON CONTACTOR 3 / 4 POLE AND CONTROL RELAYS AC/DC
LAD-N11 1 N/O + 1 N/C LAD-N20 2 N/O 1,000
LAD-N22 2 N/O + 2 N/C 1,700
LAD-N31 3 N/O + 1 N/C LAD-N13 1 N/O + 3 N/C 1,700
LAD-N40 4 N/O 1,700
LAD-8N11 1 N/O + 1 N/C LAD-8N20 2 N/O SIDE MOUNTED 2,000

Other Coil Voltages : + 10% ( 400, 110, 48, 24 VAC )


* Rated at 40o
(1) Upper limit of temperature category conforming to IEC-70.

PRICES ARE INCLUSIVE OF GST


PRICE LIST OF AZCORP ENGINEERING SERVICES Page 1 of 5
DISTRIBUTOR SINCE 1985
PL-01/2020 PRICE LIST 15-05-2020

AIR BREAK MAGNETIC CONTACTORS, 4 POLE: ( 220VAC Coil )


MAGNETIC CONTACTOR CURRENT RATING AC1 AND AC3: TeSys
CURRENT RATING AND MOTOR kW (HP) UNIT RATE
AUXILIARY OPERATING CYCLES UPTO 440V AT 415V (Rs.)
NEW TYPE o
AC 1 up to 55 C AC 3 up to 55 C
o
AC 3; < 55 C
o
CONTACTS
AMPS AMPS PL : 2020
LC1-DT20 1N/O+1N/C 25 A 9 4 ( 5.5 ) 5,500
LC1-DT25 1N/O+1N/C 25 A 12 5.5 ( 7.5 ) 5,800
LC1-DT40 1N/O+1N/C 40 A 25 A 11 ( 15 ) 7,800
LC1-DT60AM7 1N/O+1N/C 60 A 40 A 22 ( 30 ) 13,000
LC1-DT80 1N/O+1N/C 80 A 65 A 37 ( 50 ) 22,500
LC1-D80004 NOT INCLUDED 125 A 80 A 45 ( 60 ) 25,000
LC1-F1154 NOT INCLUDED 200 A 115 A 59 ( 77 ) 50,000
LC1-F1504 NOT INCLUDED 250 A 150 A 80 ( 105 ) 56,000
LC1F1854 NOT INCLUDED 275A 185A 100 ( 134 ) 78,000
LC1F2254 NOT INCLUDED 315A * 225A 110 ( 147 ) 85,000
LC1F2654 NOT INCLUDED 350A * 265A 140 ( 175 ) 108,000
LC1F3304 NOT INCLUDED 400A * 330A 140 ( 175 ) 125,000
LC1-F4004 NOT INCLUDED 500A * 400A 220 ( 265 ) 160,000
LC1F5004M7 NOT INCLUDED 700A * 500A 280 ( 330 ) 230,000
LC1F6304 NOT INCLUDED 1,000A * 630A 375 ( 445 ) 270,000
MECHANICAL INTERLOCK FOR CONTACTORS ( with integral electrical interlocking ) FOR
HORIZONTAL MOUNTING.
LAD-9R1V for LC1 - D09 ~ D38 ( Reversing Kit ) 2,500
LA9-D4002 for LC1-D80, D95 4,600
LA9-D11502 for LC1-D115 & D150 6,500
MECHANICAL INTERLOCK FOR CONTACTORS ( HORIZONTAL MOUNTING ).
LAD-9V2 for LC1 - D09 ~ D38 ( Without Electrical I/L ) 2,500
LAD-4CM for LC1 - D40A ~ D65A ( Without Electrical I/L ) 2,600
LA9-FF970 for LC1/ CRI-F115/4 ~ F150/4 3,000
LA9-FG970 for LC1/ CRI-F185/4 ~ F225/4 3,100
LA9-FJ970 for LC1/ CRI-F265/4 ~ F500/4 4,500
LA9-FL970 for LC1/ CRI-F630/4 7,500
MAGNETIC LATCH BLOCK ( manual or electric un-latching ) 220 / 240V. 50 / 60Hz.
LAD-6K10M for LC1-D09 ~ D38, LC1-DT20 ~ DT60 11,500
LA6-DK20M for LC1-D80 ~ D150 11,500
ELECTRONIC TIMING RELAYS WITH DIN RAIL MOUNTING; WIDTH 22.5 MM.
RE17RAMU 24VAC/DC & 220 ~ 240VAC; 1C/O, ON-DELAY 1s ~ 100h 4,300
RE8-TA41BUTQ 24VAC/DC & 220 ~ 240VAC; 1C/O, ON-DELAY 20 S ~ 30 Min 3,700
RE5-TA211MTQ 24VAC/DC & 220 ~ 240VAC; 1C/O, ON-DELAY 3 ~ 300 Secs. 3,700
RE8-TA31BUTQ 24VAC/DC & 220 ~ 240VAC; 1C/O, ON-DELAY 0 ~ 30 Secs. 3,700
RE8-YG21BUTQ 24VAC/DC & 220 ~ 240VAC; 1C/O, STAR DELTA 3 ~ 300 Secs. 5,500
RE22R1QCMU 24VAC/DC & 220 ~ 240VAC; 1C/O, STAR DELTA 3 ~ 300 Secs. 6,400
VOLTAGE MONITORING / MEASUREMENT RELAYS:
Phase rotation/failure, ( adjustable under / over voltadge threshold)
RM22TR33
3 x 3~420V, 50/60 Hz: 0.1~10 Sec Delay ; 300 ~ 500V
Multifunction Control Relay, Phase Failure Deduction, Phase Sequence,
RM35TF30
Under voltage & Over voltage, Detection.
TIME DELAY AUXILIARY CONTACT BLOCK (1N/O+1N/C) FOR MOUNTING ON CONTRACTOR LC-D..
a ) Delay on Energization. (ON-DELAY)
LAD-T0 LA2-DT0 0.1 ~ 3 Sec. 5,000
LAD-T2 LA2-DT2 0.1 ~ 30 Sec. 5,000
LAD-T4 LA2-DT4 10 ~ 180 Sec. 5,100
b ) Delay on De-Energization. (OFF-DELAY)
LAD-R2 LA3-DR2 0.1 ~ 30 sec. 5,400
LAD-R4 LA3-DR4 10 ~ 180 Sec. 5,400
c ) Star-Delta Changeover
LA2-DS2 1N/O+1N/C 0.1 ~ 30 sec. 6,000

PRICES ARE INCLUSIVE OF GST


PRICE LIST OF AZCORP ENGINEERING SERVICES
DISTRIBUTOR SINCE 1985 Page 2 of 5
PL-01/2020 PRICE LIST 15-05-2020

THERMAL OVERLOAD RELAYS, DIFFERENTIAL TYPE, THREE ELEMENTS,


WITH PHASE FAILURE PROTECTION, CLASS 10 (IEC947-4) .
UNIT RATE
(Rs.) PL -
NEW TYPE DESCRIPTION SETTING RANGE, AMPS CONTACTOR 2020
LRD-01 Thermal Type 0.10 … 0.16A D09 ~ D32 2,800
LRD-02 Thermal Type 0.16 … 0.25A D09 ~ D32 2,800
LRD-03 Thermal Type 0.25 … 0.40A D09 ~ D32 2,800
LRD-04 Thermal Type 0.40 … 0.63A D09 ~ D32 2,800
LRD-05 Thermal Type 0.63 … 1.0 A D09 ~ D32 2,600
LRD-06 Thermal Type 1.0 … 1.6 A D09 ~ D32 2,600
LRD-07 Thermal Type 1.6 … 2.5 A D09 ~ D32 2,600
LRD-08 Thermal Type 2.5 … 4.0 A D09 ~ D32 2,600
LRD-10 Thermal Type 4.0 … 6.0 A D09 ~ D32 2,660
LRD-12 Thermal Type 5.5 … 8.0 A D09 ~ D32 2,600
LRD-14 Thermal Type 7.0 … 10 A D09 ~ D32 2,600
LRD-16 Thermal Type 9.0 … 13 A D12 ~ D32 2,600
LRD-21 Thermal Type 12 … 18 A D18 ~ D32 2,800
LRD-22 Thermal Type 17 … 25 A D25 & D32 2,800
LRD-32 Thermal Type 23 … 32 A D25 & D38 3,800
LRD-332, LRD340 Thermal Type 30 … 40 A D40A 8,600
LRD-350 Thermal Type 37 … 50 A D50A 8,600
LRD-365 Thermal Type 48 … 65 A D65A 8,600
LRD-3353 Thermal Type 23 … 32 A D80
D80 ~ D95
D95 11,500
LRD-3355 Thermal Type 30 … 40 A D80 ~ D95 11,500
LRD-3357 Thermal Type 37 … 50 A D80 ~ D95 11,500
LRD-3359 Thermal Type 48 … 65 A D80 ~ D95 11,500
LRD-3361 Thermal Type 55 … 70 A D80 ~ D95 12,000
LRD-3363 Thermal Type 63 … 80 A D80 ~ D95 13,000
LRD-3365 Thermal Type 80 … 104 A D80 ~ D95 13,000
LRD4367 Thermal Type 95 … 120 A D115 & D150 16,500
LRD4369 Thermal Type 110 … 140 A D115 & D150 17,000
LR9-F5367 ELECTRONIC TYPE 60 … 100 A F115, F185 34,000
LR9-F5369 ELECTRONIC TYPE 90 … 150 A F115, F185 35,000
LR9-F5371 ELECTRONIC TYPE 132 … 220 A F225 & F265 36,000
LR9-F7375 ELECTRONIC TYPE 200 … 330 A F225 ~ F500 48,000
LR9-F7379 ELECTRONIC TYPE 300 … 500 A F225 ~ F500 50,000
LR9-F7381 ELECTRONIC TYPE 380 … 630 A F400 ~ F800 60,000
OTHER TYPES
TERMINAL BLOCK FOR OVERLOAD RELAYS FOR SEPARATE OR RAIL MOUNTING:
LAD-7B106 FOR LRD-01 / 32 Separate Mountong Type 1,700
LA7D1064 FOR LR2D / LR3D Separate Mountong Type 2,700
LA7D3058 FOR LRD335- Contactor Mounting Type LC1D115 ~ D150 3,700
LA7-D3064 FOR LR2-D33/LRD-335 Contactor Mounting Type LC1D115 ~ D150 4,100
ELECTRONIC OVER CURRENT RELAYS ( EOCR )
LT4706M7S Range 0.5 - 6 Amps 1 - 30 Sec 6,000
LT4730M7S Range 3 - 30 Amps 1 - 30 Sec 5,500
LT4760M7S Range 5 - 60 Amps 1 - 30 Sec 6,200
EOCRSS - 05S Range 0.5 - 6 Amps 1 - 30 Sec 4,600
EOCR SS- 60S Range 5 - 60 Amps 1 - 30 Sec 4,600

PRICES
PR ARE
ICES AR OF
E INCLUSIVE O GST
FGST
LIST OF AZCORP ENGIN
PRICE LIST ENGINEERING
EERING SERVICES
DISTRIBUTOR SINCE 1985
DISTRIBUTOR of 5
Page 3 of
PL-01/2020 PRICE LIST 15-05-2020

MOTOR CIRCUIT BREAKERS ( THERMAL & MAGNETIC PROTECTION ) :


GV2 & GV3 are 3 pole thermal and magnetic circuit breakers specially designed for control and
protection of motors. Conforming to IEC, 947-2 and 947 - 4 -1 VDE & BSS specifications having
adjustable thermal trip and magnetic trip set at 13 x Ir ( approx.) with phase failure protection.
Mounting on DIN rail.

UNIT RATE (Rs.)


TYPE Icu at 415V Ics at 415V THERMAL TRIP MAGNETIC TRIP Id 20%
PL : 2020
GV2 - ME01 > 100 kA > 100 kA 0.1 … 0.16A 1.5 6,000
GV2 - ME02 > 100 kA > 100 kA 0.16 … 0.25A 2.4 6,000
GV2 - ME03 > 100 kA > 100 kA 0.25 … 0.40A 5 5,400
GV2 - ME04 > 100 kA > 100 kA 0.4 … 0.63A 8 5,400
GV2 - ME05 > 100 kA > 100 kA 0.63 … 1.0 A 13 5,000
GV2 - ME06 > 100 kA > 100 kA 1.0 … 1.6 A 22.5 5,000
GV2 - ME07 > 100 kA > 100 kA 1.6 … 2.5 A 33.5 5,000
GV2 - ME08 > 100 kA > 100 kA 2.5 … 4.0 A 51 5,000
GV2 - ME10 > 100 kA > 100 kA 4.0 … 6.3 A 78 5,000
GV2 - ME14 > 100 kA > 100 kA 6.0 … 10 A 138 5,000
GV2 - ME16 15 kA 7.5 kA 9.0 … 14 A 170 4,400
GV2 - ME20 15 kA 7.5 kA 13 … 18 A 223 4,400
GV2 - ME 21
ME21 15 kA
15 6.0 kA 17 … 23 A 32
3277 4,800
4,800
GV2 - ME22 15 kA 6.0 kA 20 … 25 A 327 4,800
GV2 - ME32 10 kA - 24 … 32 A 416 6,600
GV2 - P05 > 100 kA > 100 kA 0.63 … 1.0 A 13 8,500
GV2 - P06 > 100 kA > 100 kA 1.0 … 1.6 A 22.5 8,500
GV2 - P07 > 100 kA > 100 kA 1.6 … 2.5 A 33.5 8,500
GV2 - P08 > 100 kA > 100 kA 2.5 … 4.0 A 51 8,500
GV2 - P10 > 100 kA > 100 kA 4.0 … 6.3 A 78 8,500
GV2 - P14 > 100 kA > 100 kA 6.0 … 10 A 138 8,500
GV2 - P16 > 100 kA > 100 kA 9.0 … 14 A 170 7,800
GV2 - P20 50 kA 25 kA 13 … 18 A 223 7,800
GV2 - P21 50 kA 25 kA 17 … 23 A 327 7,800
GV2 - P22 15 kA 6.0 kA 20 … 25 A 327 7,800
GV2 - P32 10 kA - 24 … 32 A 416 14,000
GV3-P40 35 kA 17.5 kA 30 … 40 A 560 14,000
GV3-P50 35 kA 17.5 kA 37 … 50 A 700 14,500
GV3-P65 35 kA 17.5 kA 48 … 65 A 880 14,500
GV3-ME80 35 kA 17.5 kA 56 … 80 A 1100 16,800
ACCESSORIES FOR MOTOR CIRCUIT BREAKERS :
ACCESSORIES FOR GV2-M & GV2-P
Auxiliary Switch, GVAE11 (N/O + N/C) front 600
Auxiliary Switch, GVAE20 (N/O + N/O) front 600
Auxiliary Switch, GVAN11 (N/O + N/C) side 1,100
Auxiliary Switch, GVAN20 (N/O + N/O) side 1,100
Fault Signalling Auxiliary Contact. GVAD1010 (N/O+N/O) side 1,700
Fault Signalling Auxiliary Contact. GVAD0110 (N/O+N/C) side 1,700
Short Circuit Signalling GV-AM11 ( 1C/O ) 1,700
Enclosure, Surface Mounting, Double Insulated IP 41 ( For GV2-ME ) GV2-MC01 1,800
Enclosure, Surface Mounting, Double Insulated IP 55 ( For GV2-ME ) GV2-MC02 2,500
Ext.Rotary Handle for GV2 GV2APK01 5,000
ACCESSORIES FOR GV3-ME:
Aux. Switch Instantaneous (1N/O+1N/O) GV3-A02 / GV3-A01 (1NO+1NC) 1,700
Fault Signalling Contact ( 1N/O ) P RICES GV3-A09
PRICES INCLUSIVE
ARE IN CLUSIVE OF GST 3,800
PRICE LIST OF AZCORP ENGINEERING SERVICES
DISTRIBUTOR SINCE 1985
DISTRIBUTOR Page 4 of 5
PL-01/2020 PRICE LIST 15-05-2020

CONTROL & INDICATION PRODUCTS:


UNIT RATE
TYPE SPECIFICATION
(Rs.) PL : 2020
PUSH BUTTONS 22/25 MM;
XB7 NA 21 / 31 Push Button, Latch Type BLACK / GREEN 1 N/O 670
XB7 NA 42 Push Button, Latch Type RED 1 N/C 670
XB4 BA 21 / 31 Push Button, Flush Type BLACK / GREEN 1 N/O 1,420
XB4 BA 42 Push Button, Flush Type RED 1 N/C 1,420
XB4 BP21 / BP31 Push Button, Booted, IP67 BLACK / GREEN 1 N/O 2,200
XB4 BP42 Push Button, Booted, IP67 RED 1 N/C 2,200
XB4 BW3365 Illuminated P.B Spring Return Green ( Without Bulb ) 1N/O + 1N/C 2,600
XB4 BW3465 Illuminated P.B Spring Return Red ( Without Bulb ) 1N/O + 1N/C 2,600
PUSH BUTTON, LATCHING; (Push "ON" Push "OFF");
XB7 NH21 / NH31 PUSH ON - PUSH OFF BLACK / GREEN 1 N/O 1,350
XB7 NH25 PUSH ON - PUSH OFF BLACK 1 C/O 1,350
EMERGENCY STOP PUSH BUTTON;
XB7 ES545P Turn to Release 1 N/O + 1 N/C 2,600
XB7 ES145P Key Switch 1 N/O + 1 N/C 4,000
XB4 BS142 Mush Room 40 mm, Key release 1 N/C
N/C 4,200
XB4 BS8442 Mush Room 40mm,Turn to release. 1 N/C 3,400
PILOT LIGHTS; 22/25 MM WITH LED BULB: 230VAC
XB7EV07MP CLEAR 560
XB7EV06MP BLUE 560
XB7EV03MP /04 /05 GREEN / RED / YELLOW 53 0
SELECTOR SWITCHES:
SELECTOR
XB7 ND21 Selector Switch 2 Position, Black Handle 1 N/O 800
XB7 ND25 Selector Switch 2 Position, Black Handle 1 N/O + 1 N/C 1,060
XB7 ND33 Selector Switch 3 Position, Black Handle 1 N/O + 1 N/O 1,100
XB7 NG21 Selector Switch 2 Position, Key Switch 1 N/O 1,800
XB7 NG33 Selector Switch 3 Position, Key Switch 1 N/O + 1 N/O 1,920
XB4 BD21 Selector Switch, 2 Position (stay put) 1 N/O 1,900
XB4 BD25 Selector Switch 2 Position (stay put) 1 N/O + 1 N/C 2,500
XB4 BD / BJ33 Selector Switch, 3 Position (stay put) 1 N/O + 1 N/O 2400 / 2400
XB4 BD / BJ53 Spring Return to Centre, 3 Position 1 N/O + 1 N/O 2700 / 2700
XB4 BG21 Key Switch, 2 Position (stay put) 1 N/O 5,500
XB4 BG33 Key Switch 3 Position (stay put) 1 N/O + 1 N/O 6,200
CONTROL STATIONS:
XALD01 Empty Box ( 1 Hole ) 1,500
XALD02 Empty Box ( 2 Hole ) 2,000
XALD03 Empty Box ( 3 Hole ) 2,400
Mush Room Head 40mm
XAL K178E 1N/O + 1N/C 4,800
Turn To Relase with enclosure
XAL D215 Control Station IP 66 Green & Red Push Button 1N/O + 1N/C 5,600

PRICES ARE INCLUSIVE OF GST


PRICE LIST OF AZCORP ENGINEERING SERVICES
DISTRIBUTOR SINCE 1985 Page 5 of 5

You might also like