DIGITAL BIOMETRIC RULER

PACSCAN 300 SERIES


Sonomed Escalon Accuracy
A combination of high frequency, low noise
probes and proprietary algorithms enables

PacScan 300 Series scan capture immediately upon applanation


along the visual axis with precise measurement

Digital Biometric Ruler


of corneal thickness, ACD, lens thickness, and
axial length.

Sonomed Escalon Usability


Intuitive interface, customized set-up, precise
Over 30 years of leadership in algorithms, and advanced hardware designs
enable quick and easy examination of differ-
ophthalmic ultrasound brings you the ent eye types.

PacScan 300 series, portable, digital Sonomed Escalon Reliability


biometric ruler. Consistent and accurate results, time after
time, year after year, we build unparalleled
quality into every ultrasound system. Sonomed
Escalon is still supporting instruments manu-
factured over 20 years ago.
SE-U-0201-A

Features: Touch screen for easy operation


Easy automatic calibration functions
Sonomed Escalon dependability and accuracy

1. General: Measurements: 3. Pachymeter:


• ACD, Lens, Vitreous, and AXL
Models: • Individual Zone Velocities Scan Modes:
300A A-Scan Only • Average with Standard Deviations
• Map 1: 1 Point/Single Scan

300P Pachymeter Only • Map 2: 1 Point/Multiple Scans

300AP A-Scan/Pachymeter Formulas:


• Map 3: 5 Point/Single Scan
• Map 4: 5 Point/Multiple Scans
• Available IOL Formulas:
PacScan 300 Series Features: • CCT Corrected IOP
Binkhorst
• Touch Screen User Interface
Regression-II
• Large High Contrast LCD Measurements:
Theoretic/T
• 5 Programmable User Profiles • Variable Corneal Velocity
Holladay
• Portable Design Weighing 6 lbs (3 kg) • Automatic Sensing Algorithm
Hoffer-Q
• Scan Viewer Archiving Software • Measure Review Mode
Haigis
• Power Requirements: • 256 Scan Average with Standard Deviation
• Post-Refractive
IOL Formulas:
PacScan System: 5W/90-250VAC • Measurement Accuracy Test (±1 Micron)
Latkany Myopic Regression
Optional Printer: 9W/90-250VAC
Latkany Hyperopic
Specifications:
Aramberri Double-K • 125-1000 Micron Range
2. A-Scan: • Clinical Accuracy ±5 Microns
Accuracy: • Electronic Accuracy ± 1 Micron
Scan Modes:
• Clinical Accuracy ±0.1mm
• Direct Contact/Immersion
• Electrical Accuracy ±0.0484mm
• 5 Examination Modes: Pachymeter Probe Styles:
Cataract • 20 MHz Straight Pachymeter Probe for
A-Scan Probe Styles:
Dense Cataract Use When Patient is in Sitting Position
• Standard A-Scan Probe for Hand-Held,
Aphakic • 20 MHz 45 Degree Angled Pachymeter
Immersion, or Slit Lamp Mounted
Pseudophakic (5 settings) Probe for Use When Patient is in
Application
Manual Supine Position
• Soft-Touch A-Scan Probe for Hand-Held
• Review Screen for A-Scan

Measurement Review Capability Use Minimizing Corneal Compression

01 02 03
01 Model 300AP A-Scan / Pachymeter
02 Model 300A A-Scan Only
03 Model 300P Pachymeter Only
04 Direct Contact A-Scan Probe
05 Soft-Touch A-Scan Probe
06 Adjustable Legs for Angled Viewing
from 0 to 45 Degrees
04 05 06
07 20 MHz Straight Pachymeter Probe
08 20 MHz 45 Degree Angled
Pachymeter Probe

07 06

Sonomed Escalon, 1979 Marcus Avenue C105, Lake Success, NY 11042 Tel 800-227-1285 Fax 516-354-0900 www.sonomedescalon.com