You are on page 1of 1

NORTH PIN NO.

PLANNING NO.
N
Kiblah KEY PLAN

9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 NOTES:

A A +4.80
t.o.p
KEYPLAN

FOR CONTINUATION
REFER TO DRAINAGE
SERVICE SITE PLAN BED ROOM BED ROOM
4.00x5.50
+0.45 4.00x5.50
f.f.lvl.
+0.35
s.s.lvl. BED ROOM +0.45
f.f.lvl.
4.00x5.50 +0.35
s.s.lvl.
+0.45
f.f.lvl.
+0.35
s.s.lvl.

DUCT.
B B
+0.43

slope.
slope.
f.f.lvl. MH-10
C.LEV.=+0.00
BATH LOBBY I.LEV.=-0.50m +4.80 RIDG LINE +4.80
t.o.p t.o.p
LOBBY CORRIDOR. +0.43 BATH DEPTH=0.50m

slope.

slope.
MH-02 f.f.lvl.
COVER LEVEL=+0.00m ±0.25
s.s.lvl.
ROOF
INVERT LEVEL=-1.00 ±0.25
s.s.lvl. +3.65
s.s.lvl.
C
SYMBOL ABBREVIATION

C
DEPTH=1.00m
+4.80
t.o.p W.P WASTE PIPE

SP SOIL PIPE

V.P VENT PIPE

RWP RAIN WATER PIPE

DUCT.
D D
FD FLOOR DRAIN
MH-03
COVER LEVEL=+0.00m FCO FLOOR CLEAN OUT

INVERT LEVEL=-0.98
DEPTH=0.98m
MAJLIS TD TERRACE DRAIN

W/C 5.20x5.10 RWO RAIN WATER OUTLET

KITCHEN F/A FROM ABOVE


+0.43
f.f.lvl. +0.45 T/B TO DOWN
±0.25
s.s.lvl. f.f.lvl. +0.43
U/S UNDER SLAP

E +0.35
s.s.lvl. ENTRANCE.
f.f.lvl.
±0.25
s.s.lvl.
E H/L

BOP
HIGH LEVEL

BOTTOM OF PIPE

1.30x1.60
+0.43
f.f.lvl.
±0.25
s.s.lvl.

F F +4.80
t.o.p

+3.65
s.s.lvl.

MH-11
C.LEV.=+0.00
I.LEV.=-0.60m
MH-04 DEPTH=0.60m
COVER LEVEL=+0.00m
INVERT LEVEL=-0.93
PROPOSED
DEPTH=0.99m MOSQUE-DM11 WITH
IMAM HOUSE TYPE 5A
IMAM HOUSE GROUND FLOOR PLAN IMAM HOUSE ROOF FLOOR PLAN
A. B.
FOR CONTINUATION SCALE: 1:50 SCALE: 1:50
REFER TO DRAINAGE
SERVICE SITE PLAN

MANHOLE SCHEDULE

COVER LEVEL INVERT LEVEL DEPTH SIZE MANHOLE COVER


MH.NO. (m) (m) (m) (m) (m) TYPE

MH-01 +0.00 -1.23 1.23 600x600 600x600 HEAVY DUTY (DUCTILE IRON) B
MH-02 +0.00 -1.00 1.00 600x600 600x600 HEAVY DUTY (DUCTILE IRON) B
MH-03 +0.00 -0.98 0.98 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) B
MH-04 +0.00 -0.93 0.93 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) B
MH-05 +0.00 -0.78 0.78 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-06 +0.00 -0.70 0.70 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-07 +0.00 -0.61 0.61 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-08 +0.00 -0.55 0.55 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-09 +0.00 -0.45 0.45 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-10 +0.00 -0.50 0.50 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-11 +0.00 -0.60 0.60 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A IMAM HOUSE FLOOR PLAN
DRAINAGE SYSTEM
NOTE: +0.000 IS CONSIDERED AS FINISH INTERLOCK LEVEL FLOOR DRAIN TYPICAL ARRANGEMENT ROOF DRAIN TYPICAL ARRANGEMENT
1. 2.
SCALE: NTS SCALE: NTS

AWQ/04/10-LCC-ME-DR-IM-01 00