You are on page 1of 1

NORTH PIN NO.

PLANNING NO.
N
Kiblah KEY PLAN

NOTES:

KEYPLAN

MANHOLE SCHEDULE

COVER LEVEL INVERT LEVEL DEPTH SIZE MANHOLE COVER


MH.NO. (m) (m) (m) (m) (m) TYPE

MH-01 +0.00 -1.23 1.23 600x600 600x600 HEAVY DUTY (DUCTILE IRON) B
MH-02 +0.00 -1.00 1.00 600x600 600x600 HEAVY DUTY (DUCTILE IRON) B

DUCT.
MH-03 +0.00 -0.98 0.98 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) B
MH-04 +0.00 -0.93 0.93 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) B
MH-05 +0.00 -0.78 0.78 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-06 +0.00 -0.70 0.70 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-07 +0.00 -0.61 0.61 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-08 +0.00 -0.55 0.55 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-09 +0.00 -0.45 0.45 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
MH-10 +0.00 -0.50 0.50 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A SYMBOL ABBREVIATION

W.P WASTE PIPE


MH-11 +0.00 -0.60 0.60 600x600 600x600 MEDIUM DUTY (DUCTILE IRON) A
SP SOIL PIPE
NOTE: +0.000 IS CONSIDERED AS FINISH INTERLOCK LEVEL
V.P VENT PIPE

RWP RAIN WATER PIPE

FLOOR DRAIN

FLOOR CLEAN OUT

RWO RAIN WATER OUTLET

F/A FROM ABOVE

T/B TO DOWN

U/S UNDER SLAP

H/L HIGH LEVEL

BOP BOTTOM OF PIPE

MH-09
COVER LEVEL=+0.00m 1.
FLOOR DRAIN TYPICAL ARRANGEMENT PROPOSED
INVERT LEVEL=-0.45m
DEPTH=0.45m
SCALE: NTS MOSQUE-DM11 WITH
IMAM HOUSE TYPE 5A

FOR CONTINUATION
REFER TO DRAINAGE
SERVICE SITE PLAN

FLOOR CLEANOUT TYPICAL ARRANGEMENT


2.
SCALE: NTS
MOSQUE GROUND FLOOR PLAN
DRAINAGE SYSTEM

MOSQUE GROUND FLOOR PLAN


MH-08 MH-07 MH-06 MH-05 A.
COVER LEVEL=+0.00m COVER LEVEL=+0.00m COVER LEVEL=+0.00m COVER LEVEL=+0.00m SCALE: 1:60
INVERT LEVEL=-0.55m INVERT LEVEL=-0.55m INVERT LEVEL=-0.70 INVERT LEVEL=-0.78
AWQ/04/10-LCC-ME-DR-MO-GF-01 00
DEPTH=0.55m DEPTH=0.55m DEPTH=0.70m DEPTH=0.78m